Loading...
HomeMy WebLinkAbout32526-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33382 Date: 11/10/08 THIS CERTIFIES that the building NEW DWELLING Location of Property: 1955 BAY SHORE RD GREENPORT (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 53 Block 4 Lot 10 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated NOVEMBER 21, 2006 pursuant to which Building Permit No. 32526-Z dated NOVEMBER 29, 2006 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ONE FAMILY DWELLING WITH SCREENED PORCH, DECK, SECOND STORY BALCONIES AND ATTACHED ONE CAR GARAGE AS APPLIED FOR PER ZBA # 5516 DATED 4/4/04 AND ZBA# 5851 DATED 4/13/06. The certificate is issued to JOHN M & MARION BRANDVOLD (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-04-0145 10/08/08 ELECTRICAL CERTIFICATE NO. 3042145 10/22/07 PLUMBERS CERTIFICATION DATED 11/08/07 J ZEES PLUMBING & HEATING ZIL �- ��- tho ized Signature Rev. 1/81 D oAre, �k.D ' Form No.6 ��� TOWN OF SOUTHOLD ' BUILDING DEPARTMENT 09 TOWN HALL \�W 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool$25.00, Accessory building$25.00, Additions to accessory building$25.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3., Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. New Construction: V Old or Pre-existing Building: "(check one) Location of Property: 1 9 SE LEA yle 4 9 rcot?Ai PO C_ Y j 1 q"7 j House No. Street t Hamlet Owner or Owners of Property:I` A3 —+—\ l4y0Aj smfdcl V o LC Suffolk County Tax Map No 1000, Section (%6 Block Lot Subdivision l / Permit No. j - Filed Map. Lot: Date of Permit./ - tP Applicant: 1_19,V6 Vo 16 Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ . 05/22/2008 09:15 6312988443 C CAT CO PAGE 01 p a C�.I�r,J't1't.lrJrlacJ'iJ� I:PCPt.IrJr>�c1°� r°lc.fa ' 5 L BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD OF FIRE UNDERWRITERS BUREAU OF ELECTRICITY 40 FULTON STREET -- NEW Y©RK, NY 10038 CERTIFIES THAT Upon the application-of upon premises owned by DJ CLCAT CO. JOHN BRANDVOLD MATTITUCK, NY 11962, MANHASSS T, NY D 030 5 Located tit 1955 9AYSHORE RD GREENPORT, NY 11944 5 Application/ (Number: 3042145 Certificate Number; 3042145 Section: Block: Lot: Building Permit: BDC: N837 occupant wherein the premises electricals stem consisting of Described as �t Y, Y g electrical devices and wiring, described below, located in/on the premises at: Hass nn'ul, 1"inst l'loor, Second p loor,Attached Garage,Outside,Attic, A visual inspec:time of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 herein, was c:ondttcted in accordance with the requirements of the applicable code and/or standard promulgat(-ut by the Stke of New York, Department of State Code Enforcement and Administration, or other authority having jurisdiction, and found.to be in compllance therewith on the 22ndDay of October,2007. v;uu; PLY RatG Rtltim Cir i _r e Alarm anti Emergeuey ];tluipinent S tionwr 3 0 Carbon Monoxide �`llxo, 7 0 smoke Applianvo-nod Accessories C� Exh;u„t I au 3 0 F.H.P. 4„ 1 0 30 Amps Cookilw Dt'd l 0 1 50 Amps l:ttttu•e Appliance 1 0 20 Amps I trruatt 1 0 Oil 1rVit int;:uui Pevices ��++-- c tutltx 66 0 Fixture 5 I i.�nn'�. 65 0 incandescent 1 0 Flourescent c}utlrt $7 0 General Purpose: lie�:rpr;,clt 46 0 General Purpose 45 0 General Purpose 12 0 seal '� 1�Ilnt'�1C1'4 It�c�putt:lr 1 0 20a laundry 5 Cantinucd on Neat Page 1 of 2 This certificate rnay not be.altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 S o ����11111 � E9 IBM������r����� ���� 05/22/2008 09:15 6312988443 C CAT CO PAGE 02 - � ur�WWI uur� 5 BY THIS CERTIFICATE OF COMPLIANCE THE NEW YORK BOARD OF 5 FIRE UNDERWRITERS c BUREAU OF ELECTRICITY R 40 FUL.TON STREET' - NEW •YORK, NY 10038CL � 5 CERTIFIES THAT !� C L l)pon the application of upon premises owned by C S ) �nn 1� S C--CAT CO, JOHN BRANDVOLD !r R0. BOX 27 1425 PLANDOME RD 5 MA•ITTITUCK, NY 11952, MANHASSETT, NY 11030 Located at 1955 BAYSHORE ROIGREENPORT, NY 11944 C 5 5 S Application Number: 3042146 Certificate Number: 3042145 Soctinn: Block: Lot: Building Permit: BDC: NS37 5 - 5 De;;c r(I�cci ;►;;it occupancy,wherein the premises electrical System consisting of Dj 5 (>R'C rival devices and wiring, described below, located in/on the premises at: 5 5 13aselli nt, Pir,st I','loor,Second Floor,Attached Garage,Outside,Attic, 5 A vi;;tr;il inspeci•rnrt of the premises electrical system, limited to electrical devices and wiring tb the extent detailed herein. was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other rrtithoritV having jurisdiction, and found to be In compliance therewith on the 22ndDay of October,2007. C, \:mtiv -Q-1 y li(ice xdwg Ciro(' 1 0 30a Dryer 5 5 l':u{cll; I un 4 0 5 Rvveplacic 1 0 204 Appliance 5 5 Disccmncct 1 0 60a Air Conditioner �w 5 Recept;wle ll 0 GFCI 5 sc(Vict 5 ! Ilia w ; Scrvicv Rating,200 Ampere. 1 200 ch 5 5 5 5 5 . 5 5 5 5 sea/ 5 5 2 of 2 55 - � -this curtific:ate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. ° r.P cPrJ2�P c1� 0tr rk-3 tIM iJ�[ P[P r.J�rJ�rJr.Jr n rJ� 4 trot �o Town Hall,53095 Main Road e Fax(516)765-1823 P. O. Box 1179 Telephone (516)765-1802 Southold, New York 11971 OFFICE OF THE BUILDING INSPECTOR TOWN OF SOUTHOLD C E R T I F I C A T I O N DATE: fez s f�7 Building Permit No: Owner: (please print) Plumber: J. Z . P/1- o,�-�-- d- I-}e2r�•. y (please print) I certify that the solder used in the water supply system contains less than 2/1.0 of i% lead, u ers S nature) SUSAiN J. NAGY Sworn to before me this Notary Public State of New YbO No.4896735 Qualified in Suffolk County ll//days Of 9_ CoMmission Expires May20_��_ Notary Public, County G James F. King,President *QF S�(/ryO Town Hall Jill M. Doherty,Vice-President ,`O �� 53095 Route 25 Peggy A.Dickerson P.O.Box 1179 Southold,New York 11971-0959 Dave Bergen Bob Ghosio',Jr. �Q Telephone(631) 765-1892 0 Fax(631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE #0332C Date: July 8, 2008 THIS CERTIFIES that the demolition of existing dwelling and replace with new one and one-half story dwelling with screened porch At 1955 Bay Shore Road, Greenport,New York Suffolk County Tax Map# 53-4-10 Conforms to the application for a Trustees Permit heretofore filed in this office Dated 03/02/04 pursuant to which Trustees Permit# 5879 Dated 03/24/04. Was issued, and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the demolition of existing dwellingand nd replace with new one and one-half story dwelling with screened porch The certificate is issued to JOHN &MARION BRANDVOLD owner of the aforesaid property. Authorized Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32526 Z Date NOVEMBER 29, 2006 Permission is hereby granted to: JOHN M BRANDVOLD 1425 PLANDOME RD MANHASSET,NY 11030 for DEMOLITION & CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING AS APPLIED FOR PER ZBA DECISIONS #5516 & #5851 & DEC & TRUSTEES PMTS . at premises located at 1955 BAY SHORE RD GREENPORT County Tax Map No. 473889 Section 053 Block 0004 Lot No. 010 pursuant to application dated NOVEMBER 21, 2006 and approved by the Building Inspector to expire on MAY 29, 2008 . Fee $ 1, 028 . 15 ! Authorized Signature ORIGINAL Rev. 5/8/02 r APPEALS BOARD MEMBERS �o�pS�FFO(,�cOG Southold Town Hall Ruth D. Oliva, Chairwoman c y� 53095 Main Road Gerard P. Goehririger C* a P.O. Box 1179 Lydia A. Torfora • Southold,NY 11971-0959 Vincent Orlando y O� Tel. (631) 765-1809 James Dinizio, Jr. 1 �a Fax (631) 765-9064 http://southoldtown.northfork.net BOARD OF APPEALS TOWN OF SOUTHOLD FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF NOVEMBER 4, 2004 ZBA File 5516 —JOHN and MARION BRANDVOLD Property Location: 1955 Bay Shore Road, Greenport; CTM 53-4-10 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this,review falls under the Type II category of the State's List of Actions, without an adverse effect on the environment if the project is implemented as planned. PROPERTY FACTS/DESCRIPTION: The applicant's 18,905.sq. ft. parcel has 50 ft. frontage along the east.side of Bay Shore Road, 322.18 ft. along the northerly side line, 344.03 feet along the south side line, and 54.57 feet along Pipes Cove. The property is improved with an one-story, single- family dwelling with deck as shown on the September 18, 2002 survey prepared by Joseph A. Ingegno, L.S. The existing dwelling is 52 feet to the bulkhead and has side yards at 8.9 feet and total side yard of 17.9 feet. BASIS OF APPLICATION: Building Department's March 4, 2004 Notice of Disapproval, amended March 25, 2004, citing Section 100-242A, in its denial of a building permit to construct a new single- family dwelling, after removal of the existing dwelling. The reasons stated in the Notice of Disapproval are that the dwelling will be less than 75 feet from the existing wood bulkhead, less than 10 feet in a single side yard, less than 15 feet on the opposite side, and for a total side yard area at less than 25 feet. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on April 22, 2004, at which time the Architect for the applicants requested an adjournment for submission of information relative to roof and elevation of the new dwelling. The September 14, 2004 reconvened, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence, the Zoning Board finds the following facts to be true and relevant: AREA VARIANCE RELIEF REQUESTED: The applicants wish to demolish the existing dwelling. On the 2/26/04 revised architectural site.plan, applicants propose to remove the existing home, and replace it with a new single-family, one and one-half story dwelling, adding an 8 ft. wood deck at the rear of the dwelling'and adjusting the angles of the foundation. In applicant's original request shown on the 3/22/04 schematic diagram, the proposed height was proposed at 307, to the top of the ridge, and 24-4Y2 ft. to the mid-point of the roof viewing the south elevation. Page 2—Nevember 4,2004 L_ File No. 5516_John and Marion Brandvold CTM Id: 53-4-10 ADDITIONAL INFORMATION/AMENDED RELIEF: On July 19, 2004, the applicants submitted three schematic 'designs of the north, east and west elevations and partial site plan with first and second floor living areas. During the September 14, 2004 public hearing, the architect furnished a cardboard model of the proposed building for visualization and discussion. The height was lowered as revised and shown on the 7/13/04 schematic diagram to 28 feet to the ridge: REASONS FOR, BOARD ACTION, DESCRIBED BELOW: Based on the testimony and record before the Board and personal inspection, the Board makes the following findings: 1. Grant of the area variance will not produce an undesirable change in character of neighborhood or a detriment to nearby properties. The applicant's house is one of few single-story houses left among the larger two-story house in the neighborhood along Bay Shore Road in Greenport. The proposed new 1'/2 story dwelling construction measures 60 feet x 27.9 feet with a 28 ft. height to the ridge, as shown on construction diagrams prepared 7/13/04 schematic diagram, prepared by Meryl Kramer, Architect. After adjusting the angles of the foundation, the pre-existing side yard from the north property line, plus small deck, at nine feet will be maintained, and the pre-existing side yard from the south property line at 8.9 feet will remain the same. Also the pre-existing 44.5 feet from the bulkhead will remain the same after construction, as noted on the July 13, 2004 site plan prepared by Meryl Kramer Architect. 2. The benefit sought by the applicant cannot be achieved by some method, feasible for applicants to pursue, other than an area variance. This lot is particularly long and narrow, which leaves the side yard with little or no room for expansion. The construction proposed is reasonable and logical. 3. The requested area variances are substantial and represent a 30.5 ft. reduction from the current code requirement of 75 feet from the bulkhead. The side yard variances are not substantial and represent minimal change from the pre-existing location of the dwelling and applicant's plan to keep the foundation in'place and adjust the angles to square off the dwelling to the property. 4. The difficulty was self-created. While the difficulties are related to the nonconforming size of the property and location of the existing foundation, the plan does not conform to the current Town Code requirements and is designed to meet the owners' needs for additional living floor areas. 5. No evidence has been submitted to suggest that the variance will have an adverse impact on the physical condition of the neighborhood. 6. There is no evidence that the grant of the variances will have an adverse effect or impact on the physical or environmental conditions in the neighborhood or district. yy� Page 3—November 4,2004 File No.5516—John and Marion Brandvold CTM Id: 53-4-10 RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing. test under New York Town Law 267-13, motion was offered by Member Orlando, seconded by Member Goehringer, and duly carried, to Deny the original variance as applied for, and Grant alternative relief;.as shown on the July 13, 2004 amended site plan and schematic diagrams prepared by Meryl Kramer Architect, subject to the following CONDITION: The open roofed porch and deck shall remain open. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. Vote of the Board: Ayes: Members Oliva (Chairwoman), Goehringer and Orlando. Absent were: Members Tortora and Dinizio. This R so tion was d y a t Ruth D. Oliva, Chairwoman 11/29/04 Approved for Filing `t APPEALS BOARD MEMBERS Mailing Address: Ruth D. Oliva, Chairwoman �O��QF $�(/rypl Southold Town Hall ' ` 53095 Main Road•P.O. Box 1179 Gerald P. Goehringer Southold,NY 11971-0959 James Dinizio,Jr. N ,c Office Location: Michael A. Simon �lCo , Town Annex/First Floor,North Fork Bank Leslie Kanes Weisman � 54375 Main Road(at Youngs Avenue) Southold,NY 11971 http://southoldtown.northfork.net t' CLONING BOARD OF APPEALS I• . "I AY _6 TOWN OF SOUTHOLD i + el. (631)765-1809•Fax(631)765-9064 S, OLD FINDINGS, DELIBERATIONS AND DETERMINATION MEETING OF APRIL 13, 2006 ZB File No. 5851 -JOHN and MARION BRANDVOLD Property Location: 1955 Bay Shore Road, Greenport CTM 53-4-10 SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under consideration in this application and determines that this review falls under the Type II category of the State's List of Actions, without an adverse effect on the environment if the project is implemented as planned. PROPERTY FACTS/DESCRIPTION: The applicant's 18,905 sq. ft. parcel has 50 ft. frontage along the east side of Bay Shore Road, 322.18 ft. along the northerly side line, 344.03 feet along the south side line, and 54.57 feet along Pipes Cove. The property is improved with an one-story, single-family dwelling with deck as shown on the September 18, 2002 survey prepared by Joseph A. Ingegno, L.S. The existing dwelling is 52 feet to the bulkhead and has side yards at 8.9 feet and total side yard of 17.9 feet. BASIS OF APPLICATION: Building Department's January 30, 2006 Notice of Disapproval, citing Sections 100-242A, 100-244 and 100-239.413, in its denial of an application for a building permit to construct a proposed four-foot extension to this proposed dwelling reconstruction. The reason stated by the Building Inspector in the denial is that the new construction will be less than 75 feet from the existing wood bulkhead, less than 10 feet in a single side yard, less than 15 feet on the opposite side, and for a total side yard area at less than 25 feet, and making reference to the Walz Interpretation No. 5039 for the proposed addition(s). FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on March 30, 2006, at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other,evidence, the Zoning Board finds the following facts to be true and relevant: AREA VARIANCE RELIEF REQUESTED: The applicants wish to construct an additional four-feet proposed as an extension, increasing the depth of the deck to 12 feet. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the following findings: 1. Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The deck was previously approved by this board (Appeal No. 5516) and the applicants wish to extend the deck 4 feet in order to allow for more room. The new deck extension will not extend beyond the minimum 9 ft. side yard limitation on the north side, or 9.5 feet on the south side. Also the pre-existing, nonconforming setback of 44.5 feet between the deck and the bulkhead will remain the same after construction, as noted on the July 13, 2004 site plan and revised 2/6/06 partial site plan prepared by Meryl Kramer Architect. 4 Page 2—April 13,2006 ZB File No.5851 —J.and M. Brandvold CTM No.53-4-10 2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance, the Zoning Board of Appeals must approve any changes made to an existing variance. 3. The variance granted herein is substantial. It represents nearly a 50% increase in the deck area over that approved previously by this board, although the side yard variances are not substantial and represent minimal change from the pre-existing location of the dwelling and applicant's plan to keep the foundation in place and adjust the angles to square off the dwelling to the property. 4. The difficulty has been self-created 5. No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. 6. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a four foot extension of the open deck construction, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Member Dinizio, seconded by Member Weisman, and duly carried,to GRANT the variance as applied for, as shown on the revised 2/6/06 partial site plan prepared by Meryl Kramer Architect, subject to the condition that the open roofed porch and deck remain open to the sky. Any deviation from the variance given such as extensions,or demolitions which are not shown on the applicant's diagrams or survey site maps,are not authorized under this application when involving nonconformities under the zoning code. This action does not authorize or condone any current or future use, setback or other feature of the subject property that may violate the Zoning Code,,other than such uses,setbacks and other features as are expressly addressed in this action. Vote of the Board: Ayes: Members Oliva (Chairwgman), Goehr' ger, ' izio, imon, a Weisman. This Resolution was duly adopted (5-0). G rar . Goehringer 4/25/06 pprove or Filing JAMES J. DEERKOSKI, P.E. 260 Deer Drive Mattituck,N.Y. 11952 r (631) 298-7116 Date: March 22, 2007 To: Town of Southold Building Dept. Re: Framing/Strapping Inspections Brandvold 1955 Bayshore Rd. Greenport,NY Permit# 32526 To Whom It May Concern: Framing, and Strapping Inspections were performed on the above mentioned structure and it is deemed that all work was done as per plan and meets all state and local building codes. Any questions feel free to call. _ cerely DE ��pF NFpy y Deerkoski tC ALU dam, 072 F so�ryolo �o courm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN AT N [ ] FRAMING / STRAPPING [ FIN [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFE INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: cc %-. L // DATE INSPECTOR Of SOUTyolo COUMY,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ INAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESIST T CONSTRUCTION [ ] FIRE RESISTANT PENETRATION � � 4 REMARKS� /�J l �` -ter -:f��j DATE Y� O INSPECTOR OF SOUlyo�o 'co u NMV TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [111-1-1 SULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE 7 � INSPECTOR J 32-S-2— q SOUI�o • ao cOUNiY,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTI N [ ] FOUNDATION 1ST [ OUCH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: (4- -� DATE 711P�o F souryo�o • ao �ycourm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] F UNDATION 2ND [ ] INSULATION [ FRAMING STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: Lilt""tf DATE INSPECTOR SOl/,yO�o coy,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: A64 P�7— o~ r— DATE — INSPECTOR pF SO(/l�olo O�il"OU TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 SPECTION [ /FUNDATIONN 1ST [ ] ROUGH PLBG. DATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ i ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: r q DATE Q INSPECTOR /" �� a0F SOUl9 �o� ono olycoUlm,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 "' INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG.___ [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ . ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: kN7 Pr-4-0`24�- C4vrl, is- DATE INSPECTOR - pf SO�lyo�o -3 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 C OTI -IN PE N S ] FOUNDATION 1ST [ ] ROUGH PLBG. CD [ ] FOUNDATION 2ND [ ] INSULATIO �G�v [ ] FRAMING /STRAPPING [ ] FINAL � - [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPEC =a [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION 1� 1 REMARKS: tom_ S� r DATE INSPECTOR l� i Of SO-3 (/T�o� S4 G Q couto, TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION � t z v REMARKS. 1 -12� o FIET,D INSPECTION REPORT DATE I COMMENTS _1 ,o o. - FOUNDATION(1ST) ------------------------------------- FOUNDATION(2ND) p r z _ (J) y ROUGH FRAMING& Gp PLUMBING o INSULATION PER N.Y. y STATE ENERGY CODE f V ; FINAL G CILta/ ITIONAL COMMENTS � oD Wiz° s � x Cl, d .� y TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST • BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 3 sets of Building Plans TEL:765-1802 �� �/ Survey PERMIT NO. Check Septic Form N.Y.S.D-E.C. .i Trustees Examined- 20 Ox Contact: Approved L/ 20 Mail to: Disapproved a/c 3 Phone: a� pFE g tuldt W — ---• i-_mot APPLICATION FOR BUILDING PERMIT /,� Date_��Y ,200 E, _�{O`� INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Stich a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what-so-ever until a Certificate of Occupancy is issued by the Building Inspector. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. n ure pIicant or name,if a corporation) bb $Ox f�3 , �oRNR�RT, NY A R:�I (Mailing adfress of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder A"1T' cT Name of owner of premises MAR ION V ? `-I V OG D (as on the tax roll or latest deed) If applicant is,a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of Jagg ich proposed o k i 1 be dose: House Number Street Hamlet County Tax Map No.1000 Section _ Block "+ Lot O Subdivision Filed Map No. Lot (Name) T . 2. State existing use and occupancy of premises int ed use and occancg o �ro,pQsgd con04 nl ` p a. Existing use and occupancy � �( �� ��,�Y S �J��• b. Intended use and occupancy 9 W 3. Nature of work(check which applicable):New Building Addition ✓ Alteration L— — Repair Removal Demolition Other Work Z�O OOb (Description) 4. Estimated Cost ,/ Fee (to be paid on filing this application) 5. If dwelling,number of dwelling units` 1 Number of dwelling units on each floor If garage,number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. 7. Dimensions if ' ling structures,if any:Front 2 rd'� Rear •S _Depth Height Number of Stories Dimensions of same structure with alterations or additions:Front lei - ,! Rear Depth t Height I Number of Stories I '/2 S. Dimensions o eintire new construction:Front T I"Rear—ZI I- Depth N6• DCC.�-•) Height Number of Stories t�I 9. Size of lot:Front i.JIJ Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation: ( s 13.Will lot be re-graded NO Will excess fill be removed from premises: YES NO 14.Names of Owner of remises DI ANM(! Address 14� r M Adiie Id Name of Architect Address o (Q Name of Contractor Address Phone No. 15.Is this property within 100 feet of a tidal wetland?*YES NO • IF YES,SOUT HOLD TOWN TRUSTEES PERMITS MAYBE REQUIRED 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE OF NEW YORK) SS: `CO OF i*�—being duly swom,deposes and says that(s)he is the applicant a e tldividual signin contract)above named, (S)He is the ��� (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Swo to be fore me this hisn,.i day of fi26A��20 d y NotatylPublic igna re of Applicant LI NDA J.COOPER (Notary Public,Slate of iNevV YWk No. 12�b63, Lifo,k CcrsnQt Torrn Expires Deces-relter 31, �� Permit Number REScheck Compliance Certificate Checked By/Date New York State Fa>tergy Conservation Construction Code REScheck So$ware Version 3.6 Release 2 Data filename: \\Precision\shareddocs\PROJEC--2\BRANDV—I\BRANDV—I.RCK COUNTY: Albany STATE: New York HDD: 6894 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE:Non-Electric WINDOW /WALL RATIO: 0.22 DATE: 06/09/06 COMPLIANCE: Passes Makimum UA=431 Your Home UA=422 2.1%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter Value R Valgg jT;Factor Ceiling.1: Flat Ceiling or Scissor Truss 1088 38.0 2..0 30 Ceiling 2: Cathedral Ceiling(no attic) 210 38.0 2.0 5 Skylight 1: Wood Frame, Double Pane with Low-E 4 0.560 2 Wall 1: Wood Frame, 16"o.c. 2988 21.0 2.0 123 Window: AN31: Wood Frame,Double Pane with Low-E 31 0.330 10 Window: AN281: Wood Frazee, Double Pane with Low E 18 0.330 6 Window: CXW135: Wood Frame, Double Pape with Low-E 61 0.330 20 Window: CXW155: Wood Frame, Double Pane with Low-E 65 0.330 21 Window: ANSI: Wood Frame, Double Pane with Low-E 42 0,330 14 Window: P5050: Wood Frame, Double Pane with Low E 134 0.300 40 Window: CXW 14: Wood Frame, Double Pane with Low E 96 0.330 32 Window:FWT31110: Wood Frame, Double Pane with Low-E 16 0,330 5 Window: ELFW6006: Wood Frame, Double Pane with Low E 12 0.300 3 Door, 101: Solid 21 0.280 6 Door: 101SIDELIGHT: Solid 16 0.280 5 Door. FWT460611: Glass 122 0.330 40 Door. FWH311611: Glass 21 0.330 7 Door. FWHS211611: Glass 28 0.330 9 Door 6: Solid 20 0.280 6 Floor 1: All-Wood Joist/Truss, Over Unconditioned Space 1273 30.0 2.0. 38 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been Ar designed to meet the New Yogic State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, they are attesting that to the best ofhis/her knowledge, belies; and professional jud t such plans o p cifiMtions are in compliance with this Code. Builder/Designer Date J BRANDVOLD RESIDENCE LIGHT AND VENTILATION SCHEDULE WINDOW- ROOM ROOM AREA LIGHT VENTILATION MECH.REQURED MARK UNITAREA QUANTITY AREA (SQ. FT.) REQ'D ACTUAL REgD ACTUAL B 4.5 4 18 LIV./DIN. ROOM 486 38.88 235.27 19.44 102.8 D 16.2 4 64.8 E 8.5 5 42.5 F 16.9 5 84.5 T1 5.47 1 5.47 103 20 1 20 A 5.1 3 15.3 KITCHEN 152 12.16 45.9 6.08 45.9 C 10.2 3 30.6 A 5.1 3 15.3 DEN 217 17.36 86.66 8.68 86.66 C 10.2 3 30.6 102 40.76 1 1 40.76 BATH #1 15 1.2 0 0.6 0 102 40.76 1 40.76 BR.#1 150 12 40.76 6 40.76 G 12 3 36 BR.#2 136 10.88 36 5.44 36 214 40.76 1 40.76 MASTER BR. 208 16.64 75.34 8.32 75.34 214S 11.5 2 23 T2 11.58 1 11.58 G 12 3 36 MASTER BATH 90 7.2 36 3.6 36 W/C 15 1.2 0 0.6 0 SKI 4 1 44 HALL BATH 39 3.12 4 1.56 4 A TOWN OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET 5 VILLAGE DIST. SUB. LOT f;l,. Wid HA-P4r;o,1&andvo' 1A 7,q,,/ ghoeLr 4D FORMER OWNER � N E � ACR. 'IN. M s S W TYPE OF BUILDING RES. j .6 : SEAS. VL. FARM CC-Mk CB. MISC. Mkt. Value LAND IMP. TOTAL DATE REMARKS b 560 a <5r ecv A en k fo Qwe J' Q� zz�-MutxQsk'i r ncdvo 3/6 AGE BUILDING CONDITION NE\1 NORMAL BELOW ABOVE FA Acre Value Per Value R Acre Tillable 1 Tillable 2 tillable ' 3 A(oodland Swampland FRONTAGE ON WATER ._, 'r a u /SJ4 ( 3rushland FRONTAGE ON ROAD ° -louse Plot DEPTH ``•' BULKHEAD ! /'er/v f otal - DOCK COLOR TRIM J. F (i Wes: Iy� �Y'?i! •l•Y' ' �i • .. Knt .M. Bldg. Foundation Bath /� Dinette Extension }J7 t�_ �0 D Basement Floors IC. t ® �r , . Extension Ext. Walls `� Interior Finish ����..` LR. Extension Fire Place Heat j DR. Type Roof � } Rooms 1st Floor BR. Z Porch Recreation Room Rooms 2nd Floor FIN. B. Porch Dormer Breezeway Driveway Garage UXAQo260 r 0 Total 21a' r James F.King,President ® so��� Town Hall Jill M. Doherty,Vice-President 53095 Route 25 r P.O.Box 1179 Peggy A.Dickerson Southold,New York 11971-0959 Dave Bergen John Holzapfel X" � Telephone(631)765-1892 Fax(631)765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD July 19, 2006 Meryl Kramer, Architect P.O. Box 683 Greenport, NY 11944 RE: JOHN & MARION BRANDVOLD 1955 BAY SHORE RD., GREENPORT SCTM#53-4-10 Dear Ms. Kramer: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wed, July 19, 2006: RESOLVED, that the Southold Town Board of Trustees APPROVE the Amendment to Permit#5879 to add a screened porch on the previously approved deck, and as depicted on the plans prepared by Meryl Kramer, Architect last dated July 5, 2006. This is not a determination from any other agency. If you have any questions, please call our office at (631) 765-1892. Sincerely, Ja m4psF.71ng ' President, Board of Trustees JFK:Ims James F.King,President®� �aU/'�® Town Hall Jill M.Doherty,Vice-President �� ��► P.O. Route 25 P.O.Box 1179 Peggy A. Dickerson Southold,New York 11971-0959 cos Dave Bergen John Holzapfel � Telephone(631)765-1892 f � Fax(631)765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD February 16, 2006 Meryl Kramer, Architect P.O. Box 683 Greenport, IVY 11944 RE: JOHN AND MARION BRANDVOLD 1425 PLANDOME RD., MANHASSET SCTM # 53-4-10 M Dear Ms. Kramer: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, February 15, 2006: RESOLVED, that the Southold Town Board of Trustees APPROVE the Amendment to Permit# 5879 to extend the deck an additional 4' beyond what was originally granted for a total depth of 12', and all as per the site plan drawn by Meryl Kramer revised 1/24/06. This project will need a final inspection. This is not a determination from any other agency. � �� a��and oest�o"s,please call our office at (631) 765 1892 k`r.. rr James F ing , President, Board of Trus es James F.King,President ®� sv�� Town Hall Jill M.Doherty,Vice-President 53095 Route 25 P.O.Box 1179 Peggy A.Dickerson Southold,New York 11971-0959 Dave Bergen Telephone(631)765-1892 John Holzapfel �j I'M Fax(631)765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD February 15, 2006 Ms. Meryl Kramer, Architect P.O. Box 683 Greenport, NY 11944 RE: JOHN AND MARION BARNDVOLD 1955 BAYSHORE RD., GREENPORT SCTM# 53-4-10 Dear Ms. Kramer: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, February 15, 2006: RESOLVED that the Southold Town Board of Trustees grants a One-Year Extension to Permit#5879, as issued on March 24, 2004. This is not an approval from any other agency. If you have any questions, please do not hesitate to contact this office. Sincerely, James F. King President, Board of Trustees JFK: hkc Board Of Southold Town Trustees SOUTHOLD. NEW YORK «. . PERMIT NO. ... . DATE. March 24, 2004' 13s ISSUED TO JOHN & MARION BRANDVOLD' Pursuant to the provisions of Chapter 615 of the Laws of the State of New York, 1893; and Chapter 404 of the Laws of the k State of New York 1952; and the Southold Town Ordinance en- ` titled."REGULATING AND THE PLACING OF OBSTRUCTIONS :. IN AND ON TOWN WATERS AND PUBLIC LANDS and the REMOVAL OF SAND, GRAVEL-OR OTHER MATERIALS FROM LANDS .UNDER TOWN'WATERS;" and in accordance with the Resolution of The Board adopted at a meeting held on ..Marcl ...24, 2004 and in consideration of the sum of �............................. paid by John & Marion Brandvold Iy ..............................................» -»....». ..... ....... ..... ' Gof reen ort N. Y. and. subject to the Terms and Conditions listed on the reverse side hereof, of Southold Town Trustees authorizes and permits the following: Wetland Permit to demolish the existing one-story frame house, re-use and modify existing, foundation, build new one and one- half story residence,and expand the existing wood frame deck, a and as depicted on the site plan prepared by Meryl Kramer all in accordance with the-detailed specifications as presented in .the originating application. dated February 26, 2004. The said Board of Trustees here- IN WITNESS WHEREOF, • by causes its Corporate Seal to be affixed, and these presents to r` be subscribed by a majority of the said Board .as of this date. D� Artie Foster (absent) NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION DEC PERMIT NUMBER EFFECTIVE DATE 1-4738-03328100002 November 9, 2006 FACILITY/PROGRAM NUMBER(S) PERMIT EXPIRATION DATE(S) Under the Environmental Conservation Law November 9,2011 TYPE OF PERMIT■New ❑Renewal ❑Modification■Permit to Construct ❑Permit to Operate ❑Article 15,Title 5:Protection of Waters ❑ Article 17,Titles 7,8:SPDES ❑ Article 27,Title 9; 6NYCRR 373: Hazardous Waste Management ❑ Article 15,Title 15:Water Supply ❑ Article 19:Air Pollution Control ❑ Article 34:Coastal Erosion ❑ Article 15,Title 15:Water Transport ❑ Article 23,Title 27:Mined Land Management Reclamation ❑ Article 15,Title 15:Long Island Wells ❑ Article 36:Floodplain Management ❑ Article 24:Freshwater Wetlands ❑ Article 15,Title 27: Wild,Scenic and ❑ Articles 1,3, 17,19, 27,37;6NYCRR' Recreational Rivers ■Article 25:Tidal Wetlands 380:Radiation Control ❑6NYCRR 608:Water Quality Certification ❑ Article 27,Title 7; 6NYCRR 360: Solid Waste Management PERMIT ISSUED TO TELEPHONE NUMBER Marion &John Brandvold 516 627-6747 ADDRESS OF PERMITTEE 1425 Plandome Road, Manhasset, N.Y. 11030 CONTACT PERSON FOR PERMITTED WORK TELEPHONE NUMBER Meryl Kramer, P.O. Box 683, Green port, N.Y. 11944 631 477-8736 NAME AND ADDRESS OF PROJECT/FACILITY Brandvold Property, 1955 Ba shore Rd.Green port, N.Y. COUNTY TOWN WATERCOURSE FNYTM COORDINATES Suffolk Southold Pi es Cove N: DESCRIPTION OF AUTHORIZED ACTIVITY: Demolish existing single family dwelling, abandon existing septic system, construct new single family dwelling with deck and screened porch, and install new septic system. All work shall be done in accor- dance with the attached plans stamped NYSDEC approved on 11/8106. By acceptance of this permit,the permittee agrees that the permit is contingent upon strict compliance with the ECL, all applicable regulations, the General Conditions specified and any Special Conditions included as part of this permit. DEPUTY PERMIT ADMINISTRATOR: ADDRESS Region 1 Headquarters Mark Carrara(CKW) SUNY @ Stony Brook, 50 Circle Road, Stony Brook, NY 11790-3409 AUTHORIZED SIGNATURE DATE November 9, 2006 Page 1 of 4 j� OSCj�\F� Federal Emergency Management Agency Washington, D.C. 20472 November 16,2006 MR. MERYL KRAMER CASE NO.: 06-02-13863A MERYL KRAMER,ARCHITECT COMMUNITY: TOWN OF SOUTHOLD, SUFFOLK P.O. BOX 683 COUNTY,NEW YORK GREENPORT,NY 11944 COMMUNITY NO.: 360813 DEAR MR. KRAMER: This is in reference to a request that the Federal Emergency Management Agency (FEMA) determine if the property. described in the enclosed document is located within an identified Special Flood Hazard Area, the area that would be inundated by the flood having a 1-percent chance of being equaled or exceeded in any given year (base flood), on the effective National Flood Insurance Program (NFIP) map. Using the information submitted and the effective NFIP map, our determination is shown on the attached Letter of Map Amendment (LOMA) Determination Document. This determination document provides additional information regarding the effective NFIP map, the legal description of the property and our determination. Additional documents are enclosed which provide information regarding the subject property and LOMAs. Please see the List of Enclosures below to determine which documents are enclosed. Other attachments specific to this request may be included as referenced in the Determination/Comment document. If you have any questions about this letter or any of the enclosures, please contact the FEMA Map Assistance Center toll 'free at (877) 336-2627 (877-FEMA MAP) or by letter addressed to the Federal Emergency Management Agency, 3601 Eisenhower Avenue, Suite 130, Alexandria, VA 22304-6439. Sincerely, William R.,Blanton Jr.,CFM,Chief Engineering Management Section Mitigation Division LIST OF ENCLOSURES: LOMA DETERMINATION DOCUMENT(REMOVAL) cc: State/Commonwealth NFIP Coordinator Community Map Repository Region Page 2 of 2 Date: November 16,2006 Case No.: 06-02-13863A LOMA otiy"�, Federal Emergency Management Agency °f Washington, D.C.20472 t�.vu sw� LETTER OF MAP AMENDMENT DETERMINATION DOCUMENT (REMOVAL) ATTACHMENT 1 (ADDITIONAL CONSIDERATIONS) LEGAL PROPERTY DESCRIPTION (CONTINUED) the northwesterly side of Island View Lane; Running thence N44°12'40"W along the northeasterly side of Bay Shore Road 50.00 feet to a concrete monument; THENCE N45047'20"E, 172.00 feet to a point; THENCE S65021'05"E, 53.6.1 feet to a point; THENCE S45047'20"W, 191.33 feet to the northeasterly side of Bay Shore Road and the point or place of BEGINNING. PORTIONS OF THE PROPERTY REMAIN IN THE SFHA (This Additional Consideration applies to the preceding 1 Property.) Portions of this property, but not the subject of the Determination/Comment document, may remain in the Special Flood Hazard Area. Therefore, any future construction or substantial improvement on the property remains subject to Federal, State/Commonwealth, and local regulations for floodplain management. STUDY UNDERWAY(This Additional Consideration applies to all properties in the LOMA DETERMINATION DOCUMENT(REMOVAL)) This determination is based on the flood data presently available. However, the Federal Emergency Management Agency is currently revising the National Flood Insurance Program (NFIP) map for the community. New flood data could be generated that may affect this property. When the new NFIP map is issued it will supersede this determination. The Federal requirement for the purchase of flood insurance will then be based on the newly revised NFIP map. This attachment provides additional information regarding this request. If you have any questions about this attachment, please contact the FEMA Map Assistance Center toll free at (877) 336-2627(877-FEMA MAP) or by letter addressed to the Federal Emergency Management Agency,3601 Eisenhower Avenue,Suite 130,Alexandria,VA 22304-6439. William R.Blanton Jr.,CFM,Chief Engineering Management Section Mitigation Division R(2.(0\ \1r L_0 Page 1 of 2 Date: November 16,2006 Case No.:06-02-6863A LOMA 4hRT'tr .--t 1 Federal Emergency Management A en i Y`( � - I Washington, D.C.20472 ` LETTER OF MAP AMENDMENT DETERMINATION DOCUMENT (REMOVAL) COMMUNITY AND MAP PANEL INFORMATION LEGAL PROPERTY DESCRIPTION TOWN OF SOUTHOLD,SUFFOLK Lot 32, Peconic Bay Estates, as described in the Bargain and Sale COUNTY,NEW YORK Deed, recorded as Document No. 22035, in Liber 11937, Page 227, in the Office of the County Clerk, Suffolk County, New York COMMUNITY The portion of property removed from the SFHA is more particularly described by the following metes and bounds: BEGINNING at a COMMUNITY NO.:360813 concrete monument on the northeasterly side of Bay Shore Road, distant 2,358.00 feet northwesterly from the corner formed by the . NUMBER:36103CO159G intersection of the said,road with AFFECTED MAP PANEL` DATE:51411998 FLOODING SOURCE:PIPES COVE APPROXIMATE LATITUDE 8.LONGITUDE OF PROPERTY:41.061, -72.421 SOURCE OF LAT&LONG:PRECISION MAPPING STREETS 7.0 DATUM:NAD 83 DETERMINATION OUTCOME 1%ANNUAL LOWEST LOWEST WHAT IS CHANCE' ADJACENT LOT STREET REMOVED FROM LOT BLOCK/ SUBDIVISION FLOOD FLOOD GRADE ELEVATION SECTION THE SFHA ZONE ELEVATION. ELEVATION (NGVD 29) NGVD 29 NGVD 29 32 -- Peconic Bay 1955 Bay Shore Portion of X 8.0 feet -- 9.0 feet Est. Road Property (shaded) Special Flood Hazard Area (SFHA) - The SFHA is area that would be inundated by the flood having a 1-percent chance of being equaled or exceeded in anV given year base flood). ADDITIONAL CONSIDERATIONS Please refer to the appropriate section on Attachment 1 for the additional considerations listed below. LEGAL PROPERTY DESCRIPTION PORTIONS REMAIN IN THE SFHA STUDY UNDERWAY This document provides the Federal Emergency Management Agency's determination regarding a request for a Letter of Map Amendment for the property described above. Using the information submitted and the effective National Flood Insurance Program (NFIP) map, we have determined that the described portion(s) of the property(ies) is/are not located in the SFHA, an area inundated by the flood having a 1-percent chance of being equaled or exceeded in any given year (base flood). This document amends the effective NFIP map to remove the subject property from the SFHA located on the effective NFIP map; therefore, the Federal mandatory flood insurance requirement does not apply. However, the lender has the option to continue the flood insurance requirement to protect its financial risk on the loan. A Preferred Risk Policy (PRP)is available for buildings located outside the SFHA. Information about the PRP and how one can apply is enclosed. This determination is based on the flood data presently available. The enclosed documents provide additional information regarding this determination. If you have any questions about this document, please contact the FEMA Map Assistance Center toll free at (877) 336-2627 (877-FEMA MAP) or by letter addressed to the Federal Emergency Management Agency, 3601 Eisenhower Avenue, Suite 130, Alexandria, VA 22304-6439. William R.Blanton Jr.,CFM,Chief Engineering Management Section Mitigation Division FORM NO. 3 NOTICE OF DISAPPROVAL DATE: January 30, 2006 TO: Meryl Kramer A/C Brandvold 124 Broad Street Greenport,NY 11944 Please take notice that your application dated January 30, 2006 For permit to reconstruct an existing single family dwelling at Location of property 1955 Bay Shore Road, Greenport,NY County Tax Map No. 1000 - Section 53 Block 4 Lot 10 Is returned herewith and disapproved on the following grounds: The proposed construction on this non-conforming 18,905 square foot parcel in the R-40 District, is not permitted pursuant to Article XXIV Section 100-242A which states; "Nothing in this article shall be deemed to prevent the remodeling, reconstruction or enlargement of a non-conforming building containing a conforming use provided that such action does not create any new non-conformance or increase the degree of non-conformance with regard to the regulations pertaining to such buildings." Article XXIV Section 100-244 states that on non-conforming lots less than 20,000 square feet in total size are required to have a minimum side yard setback of 10 feet and a total side yard setback of 25 feet The existing single family dwelling has a single side yard setback of 8.9 feet and a total side yard setback of 17.9 feet which will be matched by the new construction. Pursuant to the ZBA's interpretation in Walz (#5309) such additions and alterations will thus constitute an increase in nonconformance. In addition the proposed construction if not permitted pursuant to Article XXIII Section 100-239A.B., which states, "All buildings located on lots upon which a bulkhead concrete wall riprap or similar structure exists and which are adjacent to water bodies other than sounds shall be set back no less than 75 feet from the bulkhead." The existing single family dwelling notes a setback of 52 feet from the existing wood bulkhead. Following the proposed construction, the setback will be 40 feet. The applicant was grranted a variance on November 4 2004 (#5516), however the scope of the work has changed,requiring new variances. uthorized Signature J CC: file, Z.B.A. Note to Applicant: Any change or deviation to the above referenced application may require additional review from the Southold Town Building Department. FORM NO. 3 NOTICE OF DISAPPROVAL DATE: March 3, 2004 AMENDED: March 22, 2004 AMENDED: March 25, 2004 TO: Meryl Kramer A/C Brandvold 124 Broad Street Greenport,NY 11944 Please take notice that your application dated March 3, 2004 For permit to reconstruct an existing single family dwelling at Location of property: 1955 Bay Shore Road, Greenport,NY County Tax Map No. 1000 - Section 53 Block 4 Lot 10 Is returned herewith and disapproved on the following grounds: The proposed additions and alterations to an existing single family dwelling on a non-conforming 18,905 square foot lot in the Residential R-40 District is not permitted pursuant to Article XXVI Section 100-242A, which states, "Nothing in this Article shall be deemed to prevent the remodeling, reconstruction or enlargement of a nonconformingbuilding uilding containing a conforming use,provided that such action does not create any new nonconformance or increase the degree of nonconformance with regard to the regulations pertaining to such buildings." Article XXIV Section 100-244 states that on non-conforming lots less than 20,000 square feet in total size are required to have a minimum single side yard setback of 10 feet and a total side yard setback of 25 feet. The existing single-family dwelling has a single side yard setback of 8.9 feet and a total side yard setback of 17.9 which will be matched by the new construction. Pursuant to the ZBA's interpretation in Walz(#5309), such additions and alterations will thus constitute an increase in the dejzree of nonconformance. In addition the proposed construction is not permitted pursuant to Article XXIII, Section 100- 239A.B., which states, "All buildings located on lots upon which a bulkhead concrete wall, riprap or similar structure exists and which are adjacent to tidal water bodies other than sounds shall be set back no less than 75 feet from the bulkhead." The existing single family dwelling notes a setback of 52 feet from the existing wood bulkhead. Following the proposed construction, the setback will be+/-44 feet. Total lot coverage, following construction, will be+/- 11 percent. This permit was amended on March 22, 2004 to clarify the scope of the proposed work and on March 25, 2004, for additional clarification. l M Aut riz -- Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC: file, Z.B.A. FORM NO. 3 NOTICE OF DISAPPROVAL DATE: March 3, 2004 AMENDED: March 22, 2004 TO: Meryl Kramer A/C Brandvold 124 Broad Street Greenport,NY 11944 Please take notice that your application dated March 3, 2004 For permit to reconstruct an existing single family dwelling at Location of property: 1955 Bay Shore Road, Greenport,NY County Tax Map No. 1000 - Section 53 Block 4 Lot 10 Is returned herewith and disapproved on the following grounds: The proposed additions and alterations to an existing single family dwelling, on a non-conforming 18,905 square foot lot in the Residential R-40 District is not permitted pursuant to Article XXVI Section 100-242A,which states, "Nothing in this Article shall be deemed to prevent the remodeling, reconstruction or enlargement of a nonconforming building containing a conforming use,provided that such action does not create any new nonconformance or increase the degree of nonconformance with regard to the regulations pertaining to such buildings." Article XXIV Section 100-244 states that on non-conforming lots less than 20,000 square feet in total size are required to have a minimum single side yard setback of 10 feet and a total side yard setback of 25 feet The existing single-family dwelling has a single side yard setback of 8.9 feet and a total side yard setback of 17.9 which will be matched by the new construction. In addition the proposed construction is not permitted pursuant to Article XXIII Section 100- 239.4.B., which states, "All buildings located on lots upon which a bulkhead concrete wall riprap or similar structure exists and which are adjacent to tidal water bodies other than sounds shall be set back no less than 75 feet from the bulkhead." The existing single family dwelling notes a setback of 52 feet from the existing wood bulkhead. Following the proposed construction, the setback will be+/-44 feet. Total lot coverage following construction, will be+/- 11 percent. This permit was amended on March 22, 2004 to clarify the scope of the proposed work. 1 ` Authorized Si Note to Applicant: Any change or deviation to the above referenced application, may require further review by the Southold Town Building Department. CC: file, Z.B.A. LIPA December 13, 2006 Mr. John Brandvold 1425 Plandome Road Manhasset, NY 11030 RE : 1955 Bayshore Road, Greenport LIPA Ref * T100699858, Electric Mtr *094877985 Dear Mr. Brandvold: This letter is to advise you that the electric service to the above referenced premises was removed on December 7, 2006 . If you have any questions, please contact Fred Perez at (631) 548-7037 . Very truly yours, Steve Aylward Design Engineer Electric Design & Construction SA/am PHOTO#1 N/0/F a o GARY ZUAR DECK F°o KATHLEEN ZUAR - :::,-.: LOT 31 c POWER UTILITY 10 30\ s EDOE ROW e W Z ?g POLE 22N N 45'47'20°E i 6 a � I � 322.18 ::::;t5:;:. .r..:'.sasez;::s::::;:;:::ze...................::::.::::......::r;:s:;a:::z;s .._ ::............e:;::;::a::;::::.:::.:;:.::;::-......:::; .............:....�........... OUND.CONC. N P F �Q (n 0 MON.0.45 y N RASS AND DI OPOSED O DU. hx La`u O z .o S a o A DRIVEWgY 7 DEEP LFPLNINO o G] I I I \ p \D r ODUs RO OSED DECK +^ S.-s D O / bRDPO$ED 11/2 &Si RS fl I I \ \ m �\ �"` s' STORY HOUSE ADDI N -� of LOT 32 c ` �� �� Lsl \ { / / PROPOSED a D To fa �I ��A :Il oD 6' Ir `����/// TDoocwL _ REMAIN �F �I ` \`- Q �� m 1 PROPOSED S `' ! \ O C y 3 . � \� µ3)" HEDf E ROW :+ ENCE 07ro,,L \ a I 1 I \o - -• �_ - WA .- .::.::... , ENCE 0 5 WOOD FENC FOUND, I S S4 47 20 W \ ALLLEADERs EXIST.FOUND.TO \ CONC.MON. 344.03' ISTINOSEPTICTOBE W / DRAINTO I REMAIN ` And I'' ABANDONED IN-PWE DRYWELLS N PUMPDRY&FlLL WITH is 41 So e Z CLEAN SAND&ORAVEL n O TEST HO WOOD BULKHEAD Lb N/O/F BULKHEAD O.L. ro GEORGE BRAUN& JEANNE M.BRAUN oLOT 33 0 PHOTO#2 P BRAN DVOLD RESIDENCE MARTIAL SITE PLAN 1"=�4;0' �' hF REV. 1/24/06 2 M Fit Y ';� ..;;;,<<K=: A M E R c F a r c h i t t� 31 SOUTH STREET P.O:BOX 683 GREENPORT, NY 11944 631-477•8736 EL. 9.8 0.0 s e )° DARK BROWN z CAST IRON COVER TO GRADE �ryry\ �59• F FS C LOAM pL N w/ LOCKABLE COVER 5 — 8' DIA. X 3' DEEP LEACHING POOS 2 L EDGE OF BUILDING V� 1 g CROSSOVER AT 8" ABOVE BOTTOM TIE LINE EDGE BACKFlLL WITH OF MEADOW' BROWN o CLEAN SAND TO SILT ° MIN: 6' INTO.VIRGIN GRADE EL, 10,8 [SAND n a RA L. 9.8'' & GRAVEL 3 ,•qAA �A 3' g I.E. 7.9 i gRFyT..._, ._ _ . _ o 1 i , BROWN SILTY GRAVEL 1000 GAL. LEACHING ELEV,.8.3 :. q '. ti�Q 2 ' I.E. 8.8 I.E. 8,6 SEPTIC TANK I,E,i8,l POOL i ELEV.-5:3 '..;mq.rFQ _ .._..... _..- SM 4' i5 UK ELEV. 1.9 �N OOD ZONE AE (EL B) •• .� 3 BROWN FINE TO w w`n r q COARSE SAND W/ U w < s 5 q 10% GRAVEL CI) Z Y PROFILE 6 w z - �i GW-. EL, 1.9 SW 7,9' w Y o uj NO SCALE P+ Q z z tiJ WATER IN BROWN Zcn FINE TO COARSE F- �p4�P 9 ��� SAADEW/ 10Y. Z) o Z p ,m o Jay` b p J Z m SW - O - UP�o 14' c U 10 CP TEST HOLE 9 0 � R\^�� �. NO SCALE V R ���! PERFORMED BY MCDONALD GEOSCIENCE 01.09,04 T�I oryq� �Q� �`�°K 0p o-dl�Po ��'P �b� Key Map 10 7 �`\Q�ot,<lD \,l. �PJQJO� i,.J^, REENVORTS' .v 1000 GALLON �°� �� 0 zs N• SEPTIC TANK � 10 ^, p• Cv r.GRE� — 41 S' DIA. X 3' DEEP' '` 70. � ��%; � v��6 �' L G LEACHING'POOL I - o� �e cn TYPICAL , �..: i / `' PIPE COVE f `" RC � S• $ '+� ti U w EXPANSION'POOL °f_, nLT E R :Che1t Pt. 'd• ' U TYPICALZ I �.. `�. O z PROPOSED WATER LIN '� i''`% 'y`r ,; 1 G v ` , Li conkling P1 �"'b E>�n J°` H ' v SCTM 4 1000-53-04-10 4 cp, �p �i EXISTING SANITARY SYSTEM ui yN m \4, ° PTO BE REMOVED O =_ >TEST-' 10 ' SUFFOLK COu'�'9t'llI '�;�;�,a'.�;_:Pv ENT OF'�:��.°t TkI SERVICES _._�I � m Z Q u YO�.•+g�O VY j F- �, HO I z �ui w — 10TA.� ,3 0. 3 a -u 'Mill m 10 %% 0 7AT� (� f ism � j ` F.I�T .L IS , . APPROVED ��le DRAYM: CHECKED `v 'ycc �ls Sp o�' .. � ol ell coay I /�/ ._._..._. 1 FOt MAAi�ai'��'aJiVj Oi 1� '� DATE: 04.20.04 SCALE: AS NOTED v �„ � r -�„ '�i•ti�t� AFT �` 1 SAN I TARP SYaTE M PLAN I ExF►IxEs TiR �Yc�,rW rI:QIVf T�A'Zi 03:��P,,Izt�VAL ) JOB NO.: 1.1 �4�©3 �1� IfIS o e f 'rf t� yd ��°�,� SCALE: 1"="0Z Scc6na j 7` Form ww M — dD �r 9iEET ° ALL SURVEY DATA SUPPLIED BY JOSEP E �� U H A. I GNO, F LAND SURVEYOR, RIVERHEAD, NY DATED 09.18. 2EET NOF I SURVEY OrLOT 32 s s�o O � SgY, AMENDED MAP A rpm FLAG PECONIC BAY ESTATES 'Ply \ � rye \ FILE No. 1124 FILED MAY 19, 1933 ��'°� r�vy °FME^Dw°aeAaO NO SI T UA T ED A T ---�MFq ARSI-IAMOMAQUE TOWN OF SOUTHOLD FLAG SUFFOLK COUNTY, NEW YORK AL �4l"9R,r S.C. TAX No. 1000-53-04- 10 FLAG '°�k�'qR�%y SCALE 1 "=20' FLA SEPTEMBER 18, 2002 APRIL 4, 2006 LOCATED FLAGGED WETLANDS LINE SEPTEMBER 15, 2006 ADDED METES & BOUNDS DESC. APOUND LOT AREA ABOVE EL. 9.0 FEBRUARY 2, 2007 FOUNDATION LOCATION 4` S q AREA = 16,655.00 sq. ft. s (TO TIE LINE) 0.382 ac. `G o?o� 6S� O f 0 h9,( ti by o 6 9 10 \ 0 S p((` �3�� f A�Up, 3 6�• ��y� NOTE ELEVATIONS ARE REFERENCED TO N.G.V.D. 1929 DATUM EXISTING ELEVATIONS ARE SHOWN THUS: -9 EXISTING CONTOUR LINES ARE SHOWN THUS: -- s-- - - n �• 6,, .��J-n' r�pf r TOP OF FOUNDATION ' < - FIRST FLOOR GARAGE FLOOR TOP OF BULKHEAD BOTTOM OF BULKHEAD TOP OF WALL r - BOTTOM OF WALL ? 2. THIS PROPERTY IS IN FLOOD ZONE AE (EL. 8) G I�I� FLOOD INSURANCE RATE MAP No. 36103CO159 G .01 God 4�h �`"� �' lS ti1 ZONE AE: BASE FLOOD ELEVATIONS DFTERMINED 1� O •11 / / I � / / / r UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION 7209 OF THE NEW YORK STATE EDUCATION LAW. COPES OF THIS SURVEY MAP NOT BEARING EMBOSS AL SEAL SOHALL INOTDBEFCONSIDERED 46��O TO BE A VALID TRUE COPY. a CERTIFICATIONS INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY e IS PREPARED, AND ON H'S BEHALF TO THE TITLE COMPANY, GOVERNMFNTAL AGENCY AND Ap STED H[PEON, ANn TOND THE INSTITUTION ASSIGNEESOFITHE LENDING INSTI- TUTION. CERTIFICATIONS ARE NOT TRANSFERABLE. e ` O ��� °��O O THE EXISTENCE OF RIGHTS OF WAY ^ AND/OR EASEMENTS OF RECORD, IF �\ ANY, NOT SHOWN ARE NOT GUARANTEED. e O `' ?•'� PREPARED IN ACCORDANCE WITH THE MINIMUM Ip < r° STANDARDS FOR TITLE SURVEYS AS ESTABLISHED L s h A. in e ano n �c O �, BY THE L.LA.L S. AND APPROVED AND ADOPTED '�t F FOR SUCH USE BY *ip THC NEW YOF K STATE LAND ti Op�c � TITLE ASSOCInI{ON"_ v �ti•�s Land �'�� �? ' F,Py ST O gyp. r x SFs S�! Title Surveys - Subdivisions - Site Plans - Construction Layout A L PHONE (631)727-2090 Fax (E31)727-1727 tir i` OFFICES LOCATED AT MAILING ADDRESS P. 322 ROANOKE AVENUE P.O. Boy 1931 N.Y.S. Lic. No. 49668 -- --- RIVERHEAD, New York 11901 Riverhead, New Yak 11901-0965 ---- --------- .�..�- -- - - — -- - — -- — - 22-3431) . SURVEY OF s o s�o LOT 32 ���p , ALOS 4859,, T� AMENDED MAP `A FLAG " �G� �� 4•S FoAL \ F PECONIC BAY ESTATES otiFti�p AL Y'C ne FILE No. 1124 FILED MAY 19, 1933 P,l ,Glr oFMo�e Ep ps SONG \\ SITUATED A T ps ,L AL \ ARSHAMOMAQUE AL AL M"'tow A TOWN OF SOUTHOLD FLAG AL A SUFFOLK COUNTY, NEW YORK ��FgRFAL �o S.C. TAX No. 1000_ SAG 53 04 10 SCALE 1 "=20' AL AL SEPTEMBER 18, 2002 FLA APRIL 4, 2006 LOCATED FLAGGED WETLANDS LINE SEPTEMBER 15, 2006 ADDED METES & BOUNDS DESC. AROUND LOT AREA ABOVE EL. 9.0 FEBRUARY 2, 2007 FOUNDATION LOCATION JULY 15, 2008 FINAL SURVEY AREA = 16,655.00 sq. ff. (TO TIE LINE) 0.382 aC. S.C.D.H.S. NUMBER R10-04-0145 ? O \'9p. /y 00ry 7' \ QAy� ti O�q� 'IN Q � O G�. �i G p \�\x• '� try ? OCG�q,, G�' 'S• \•6• Q �• S O 5o- h,� NOTES: ?2tiF G���•��� `��<e �`v`�v 1 . THIS PROPERTY IS IN FLOOD ZONE AE (EL. 8) �p oy�o \,zo G� �0a °oo y0'S I'IWIF FLOOD INSURANCE RATE MAP No. 36103CO159 G o"D ZONE AE: BASE FLOOD ELEVATIONS DETERMINED a• �y G G� �� 2. ELEVATIONS ARE REFERENCED TO N.G.V.D. 1929 DATUM `ts• d Goo \S J / A\lo CESSPOOLS �e 00 Jk V \ UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF SECTION/ I /: O��I ; \�\ / EDUCATION2LAW.09 OF THE NEW YORK STATE o COPIES OF THIS SURVEY MAP NOT BEARING . . � THE LAND SUOR'S \ p Q{• �P / "' F"Ory� EMBOSSED SEAL SHALL INOTDBE CONSIDERED �j Otip BOG / OQ %/• CUR - TO BE A VALID TRUE COPY. °a li! o\ �OiO ., .. :'• ;/' ' A F! 04S _r e+ y CERTIFICATIONS INDICATED HEREON SHALL RUN �s l<< vQp / �•C� ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE TITLE Blp� O COMPANY, GOVERNMENTAL AGENCY AND p G ,h :". LENDING INSTITUTION LISTED HEREON, AND �\ e• ssB i TO THE ASSIGNEES OF THE LENDING INSTI- \Q'Sre // =, i! TUTION. CERTIFICATIONS ARE NOT TRANSFERABLE. \QO ticpc� �, °rr! f D i; :'j THE EXISTENCE OF RIGHTS OF WAY e e AND/OR EASEMENTS OF RECORD, IF ANY, NOT SHOWN ARE NOT GUARANTEED. C 0— % a >�a, \%O Q i .: PREPARED IN ACCORDANCE WITH THE MINIMUM 'O 0 • STANDARDS FOR TITLE SURVEYS AS ESTABLISHED • O ° A \Q� !� Q, i '� may' . BY THE LLALS. AND APPROVED AND ADOPTED Nathan Taft Corwin ��� �,OG s -r . FOR SUCH USE BY..THE-NEW.YORK STATE LAND 4 + TITLE ASSOCIATION, Land Surveyor r.. (,� � '� �,-g'tl •• 4 � 'YC s!_'? fC] <<� '�� �� ':, i �:e G70f .�i `�` :�1,»,'y/�' �O �,� +� r 1 Title Surveys — Subdivisions — Site Plans — Construction Layout F ,--.t- � Fps ' i(� = PHONE (631)727-2090 Fax (631)727-1727 7'[Nt► 1 + ✓ ) �'EyT ! �rf� 0� >� .� v ,� OFFICES LOCATED AT MAILING ADDRESS �.AT�CI�U 322 Roanoke Avenue P.O. Box 1931 (� N.Y.S. Lic. No. 50467 Riverhead, New York 11901 Riverhead, New York 11901-0965� 25 WL 7.4w 3^r• COWR.'! i�E ` PHOTO # 1 2/26/04 APPROVALS - ^• Sond a m FOR STA. S IL N/O/F Cam,,'•. 1 l �� S ; PIPES COVE �a Deriny GARY ZUAR & KATHLEEN ZUAR Fannin '` 0 o t LOT 31 'Che u ! R. QC. 0� 0 z 00 10 10 s �, :<.._ ,�w �w .=;�A ` • - o z UTILITY ? 0 POLE 2.2'N J HEDGE ROW s i 4 N 45° 47' 20" E 1 1 �° 4 3 2�322.18' i ConklinPf ? j Jt7rninys pf �aw..d. .--_/ *ND'rG1' � `a NEsI`TER b: ° i Cacsrc', HEIGHTS 7W, T o I w• ` LRe N / . - MON. 0.4'S I I \ 2 \ \ z'_U ) s° � ""' R RIVEWAY Om m gn 0UTH0LD o 11J2 i PROPOSED PROOSEDDECK _ C3 11:7 D !p }Z f� • . <E .p.. \ ) STORY HOUSE t DI 0 r of T 2 , �� �} ` h1 \ - f 30 0� I LOT 32 \ \ WOOS DE K-TO 1 g �' co 1 m to 8 A Y\ WEST NlFCK BAY z" r- y 1 �� �'t o REMAIN r- r- r_,., _ \ y► o z 0 Om r—tI" m O I I \ ` m Oath 0 O_ m \ / I I _ - FENCE 0.4'S p I \ m \ > m 0 HEDGEROW L-1-- _^� - \ z z o I ' I \ m z LOCATION PLAN o -d�- LL O.L z I ) \ o W O�D WALL W FENCE 0.2'S II WOOD FENC FOUND, 2 344.03' D S 45° 47' 2O" W \ EXIST. FOUND, TO \ CONC.MON. \ \ \ V r 10 ' REMAIN I �, \ , . 0 4 3 ►J / 0 �11 10 9 16 TEST HOLE DATA Zz WOOD BULKHEAD 0 r n o TEST HOLE N/0/F Q >� u, BULKHEAD O.L. —+ c GEORGE BRAUN & 0 oz m w JEANNE M. BRAUN ---- 1' DARK BROWN LOAM (OL m � � o BROWN SILT ML W m o LOT 33 3' BROWN SILTY SAND WITH 10%GRAVEL SM 0 -- 4' z 0 O Po "' I BROWN FINE TO COARSE SAND WITH SO%GRAVEL SW 7.9' PHOTO # 2 Q - m WATER IN BROWN FINE TO COARSE SW U1 LO SAND WITH 10%GRAVEL 14' COMMENTS: WATER ENCOUNTERED 7.9'BELOW SURFACE NOTES: 1. SURVEYINFORMATION IS TAKEN FROM SURVEY DATED SEPT 18, TEST HOLE DATA SITE PLAN 2002 BY JOSEPH A. INGEGNO LAND 1"-20'-O" S U R V EYO R 2. ELEVATIONS ARE REFERENCED TO N.G.V.D 1929 DATUM 3. PROPERTY IS IN FLOOD ZONE AE (EL 8) FLOOD INSURANCE RATE MAP NO. 36103CO159 G DRAWING LIST SITE DATA LEGEND ABBREVIATION 0 SYMBOL DESCRIPTION SYMBOL DESCRIPTION SHEET NO DRAWING TITLE DATE SCTM# 1000-53-04-10 'z epa men n erior air w SECTION SYMBOL —Above 101 DOOR NUMBER — FinishedCel in etas Kilowatt Ua I 1 TITLE PAGE WITH SITE PLAN 02/16/04 PROPERTY ADDRESS 1955 BAYSHORE ROAD,GREENPORT, NY I SECTION NUMBER A, , _0_ve Inis e Floor _ Diameter en t Radius a 5.10 SHEET NUMBER T Ame-rican-Instituute o rC I eCTS TAB eTngera or a uLu W e < PARTITION TYPE --Ain American Ins I u e o ec rlca n Ineers DIM DI MEN Dimension LBj Pound jireIc OWNER MARION AND JOHN BRANDVOLD AIS Amer can_Fnsti_t_ute of steel Construction own 1 Linear _ RQomj� ELEVATION SYMBOL A Aluminum � DQQr(S� Igt $ tain f Y ,_ CO ELEVATION NUMBER GYPSUM WALL BOARD ernaf rw . raw in ANO�1C�anu a Ure IM Imll f LOT COVERAGE SITE-16650 SF, - C m a A 2.0 SHEET NUMBER AMP TAm�ere Elevation ateria PEC_(S) SnC1f1CatL HOUSE- 1976 SF. —AR rCI11teC ecfricaMaximum Sq '� f C; '' LOT COVERAGE-12.8% ® METAL ASHRA merican 5-ocie o ea it e n era ion ngineer MAX.�MechanicaStandard m irr Conai lonin n rneers Equal MEZL ezzanine W DETAIL FLAG SYMBOL CONCRETE(SECTION) —A510fE American 5ocieT ofiMec anica n ineers cLul�men f�T Nfinimum TRtJC , Sttructur c I DETAIL NUMBER NT�lmerican OCIe�Or es In a ena s eCtriC Water Cooler TSMiscellaneous W ZONING R-40 A61 SHEET NUMBER oar--- - Exhaust Metal 0 ROUGH WOOD BLOCKING H-THK T SECTION) L IOCk Existing 0 piC- 1 . Thickness JOSEPH A INGEGNO LAND SURVEYOR , N SURVEYOR e_am —ExposedNational Electrical _e I1d�lr].t��.dflQrfltQCleS 1380 ROANOKE AVENUE RIVERHEAD, NY �0, e- iris National Electrical anu ac urers ASSOC. SEPT. 18,2002 WOOD BLOCKING Q.N UnleSSQther ise-N M f� (SECTION) O bottom Floor N,(.B. 1V�In�.O�raC 1 \/� ALLOWABLE- 35 FEET 3a-- COLUMN LINE fItISTI erma Unit00 umber e ItC ompositeZl � BUILDING HEIGHT Cabinet ire roo 0 o ca e © FINISH WOOD OLfi �elfln Fixture A—�OveralT— OL VOrITuI JEI� �° eramlc oo ink vera Imension `' � � ` BUILDING EXCEEDS MIN. REQUIREMENTS SET FORTH BY N.Y. SIC ee Per Minute With Gauge �C: on Center „ I ENERGY CODE a, !. ® PLYWOOD(LARGE SCALE) CenTe ine 8110n U SI 2 Diameter C WatflL�OS STATE RESIDENTIAL BUILDING CODE-SEE ATTACHED REPORT _ ELEVATION MARK TOSe alvanize OUndS er U IC o0 ` °'" -- __ Il Wood �� DESIGN CRITERIA Tear General E er enu ar ��A r; TYPE OF CONSTRUCTION-WOOD PLATFORM FRAMING-DOUGLAS FIR#2 NEW WALLColumn °c>• �^^�� SNOW LOAD-45 PSF. � YpSurn- 17a1TBOar ase -p Water�llOO •N'°-��..-�:... ON . Crete WR— Hardware 1'—Prate FIRST FLOOR- LL 40 PSF. Q OnS rUC on oiTo_—Me Plastic Laminate SECOND FLOOR-LL 30 PSF. EQUIPMENT NUMBER EXISTING WALL O I. Continuous HORIL Horizon aT— um In WIND SPEED-120 MPH. ————— OV'O covering FIR Hour FL D Plywood FROST LINE DEPTH- 36" 0 REVISION SYMBOL —__ DEMOLISH WALL CIRer HW Hof Water FNL Panel SEISMIC ZONE-6 UDC Feet I.D. inside Diameter POL` P7s e WEATHERING-SEVERE UIN Cubic Inch inch F OUn S per uare Foot TERMITE DAMAGE-MODERATE/HEAVY O WINDOW INSULATED WALL Cubic Yard —INCL. Include/lncludin ounds per' quare nc DECAY-MOD/H'VY Et FU— Information TO Painte ICE SHIELD UNDERLAYMENT REQUIRED Double Sul Ins_uTa_te nsuIatin9, nsu a ion ALL CONSTRUCTION SHALLAs MEET THE REQUIREMENTS OF THE ALP,. � , •6, CODES OF NEW YORK STATE. �" ;a �n CERTIFICATION OF NAILING & CONNECTIONS pp41,110ED �S NOTED �, ,, ,.., 11 REQUIRED. '7 Z1 ( �' DATE: ) B.P.#C PHOTO # 10. / BY: ,6 i a..a � )NI. T Po r � I CO.WRK = sT,�c «,.. FEE:=� � .... ,4-. - e NOTIFY BUILCI�h �EPA�,TMENT A ^STAIN STORM WATER RI INOFF 765-1602 s AP:" 4 PM FOR THE PURSUANT TO SECTOC . FOLLOWING INSY�C�!ONS: n � s,�„E; n �L 'cm• OF THE TOWN CODE. 1 ^"%..so.�a 1 FOIP, FOURED CnVOR REQUIRED ` 'J 2. ROUGH - FRt',%VING & PLUMBING 6.20.2006 PRICING 2/26/04 APPROVALS _ 3. INSULATION S IIDI 4. FINAL - CONETRUCTION MUST x�ll _ off` GREE GARY ZUAR & F o NGV� l U'� I ALL CODES OF - - KATHLEEN ZUAR DECK y �1TE & TOWN CODES BE COMPLETE FOR C.O. E!!N►D0. STA. S FALL CONSTRUCTION SHALL MEET HE REQUIREMENTS OF THE CODES OF EW AS REQUI cJ AND CONDITIONS _9' PSL LOT 31 SOI. HOLD TOWN ZBA NOT RESPONSIBLE OR LS -�1�2,'� /`�� /,•�l,N,- �hH{tN 1?' 00? ` Y.C.• � I�f •` /" I YORK STATE. ON. /" c SCREENED 29�-0° r SOUTHOLD TOWN PLANNING BOARIDESIGN OR CONSTRUCTION ERR RS. � ''• '` �� f 9 0 PIPES covle �1lerin PORCH `di i Fanning Pt :t'' '0 SO 10 a g SOUTHOLD TOWN TRUSTEES _. ......�TWo�Q'S __--- o Z 1UTIUTY OCCUPANCY OR SD e G z c� POLE 2.2'N HEDGE ROW 6 5 4 N.Y.S.DEC ��' Z �HELT :Che�rfit PC. 6� \ E IS UNLAWFUL ;,° v aPGO A N 45° 47' 20" E 1 4 a s 2 322.18' USE, NLA •�-• .�¢r�=f� � �'` ' � '� _:sh,«nl.� -� a° . i 'I � � � PLUMBER CERTIFICATION WITHOU T CERTIFI 4TE I Tuht Club 1 " FOUND. CONC. i \ \ NTENT BEFORE ,� 1 _., D.W. DROP SED 6Co 4 , \ In ,� ON LEAD CO YOF OCCUPANCY ?D. : r -� n,. „w . ., .. nP x °y MON.o.4's F OCCUPANC N.... �, EXIST. RA R E 2 I -� / ER Cf=,RTfFiCATE 0 DRIV wAyG SS AND DIRT OPOSED 8'DIA. \ O m I •p s �j l'onktirg Pt 1 I_ / �� b•'`�`r �+ 2 DEEP LEACHING c — s ° 'i\DER USD M CANNOT � �' POOL(5 �� � � " h I -----PROPOSED DECK � I � l � � �, �;- 0-0 I I PROPOSED 1 1,/2 � 2 ° -' � S r t. = - DO NOT PROCEED WITH Jennings Pi` ,«"s"v yE1U'� ,a ISL��(ND - ` i14) 4:.. s � � ( \' � �' I I I &STAIRS a � �! � � � �► o \ ' a HEIGHTS ° STORW HOUSE I F T S E�';;ELD 2i'1 G OF 1% LEAD FRAMING UNTIL SURVEY SGEM� rn \� /{?I _-� I ADDITION 134_ _g -� I I LOT 32 \ \ �, \ k, U OF FOUNDATION LOCATION ' N . Cat * \ % J PROPOSED I I -WOOD DECK TO g cn co' " I 1 m G / + ,r +U O m / 1000 GAL I �17 \ v r \\ PLUMBING HAS BEEN APPROVED. } �,.. ` _ - REMAIN D D -m- -� �► O U T H O L D �..A m pv \ \ 1 \ \ g z ALL PLUMBING WASTE Z i � - 0 �� m 1 \ PROPOSED / SE -- - r`t-- r - o o �' �_T1 ' j m & N n t.,NES NEED E D \ EXPANSION i If _ ENCE 0.4 S o �, "' UI;flERWRITERS CERTIFICATE 1H "�J \ N `' 1 1 I 3 o TESTiNG BEFORE COVERING I POOL(3) HEDGE ROW rol - �- Z Z o 1 m _47- l 1 ;� WAIL O.L 1 \ ►) \ \ � \ "' REQUIRED O WEST N'ECx BAY I .° "'" \ ObD WAIL \ -- -" BA Y \ 1 0 \ FENCE 0.2'S I WOOD FENCE FOUND, \ 1 S 45,° 47' 20" W ALL LEADERS EXIST. FOUND.TO \ CONC.MON. I i 2 344.03' FLU; - `�ATTJ Q, r EXISTING SEPTIC TO BE 10 / DRAIN TO ' REMAIN _40.5 —� 5 \ - LOCATION PLAN r ABANDONED IN-PLACE DRYWELLS J \ 6 4 9 ,'�'' I, "TER I COMPLY , . I� G� " W O N PUMP DRY&FILL WITH 10 ii So s / FLOOD DA. ,,IA,',_: PfaEVE TION F �(Zj O CLEAN SAND&GRAVEL �,, TEST HOLE � WOOD BULKHEAD SOUTHULU 1 Uv`rN CODE W Q° rri N/O/F BULKHEAD O.L. o < N GEORGE BRAUN & m JEANNE M. BRAUN TEST HOLE DATA Q M 8 LOT 33 Q N 0 ----- 1' DARK BROWN LOAM IOL BROWN SILT MIL I W ---- 3' BROWN SILTY SAND WITH 10%GRAVEL SM ®PHOTO # 2 0 BROWN FINE TO COARSE SAND WITH 10%GRAVEL SW ---- 7.9' QM W WATER IN BROWN FINE TO COARSE SW LO SAND WITH 10%GRAVEL LO VI 14' J COMMENTS: WATER ENCOUNTERED 7..9'BELOW SURFACE NOTES: 1. SURVEYINFOIRMATION IS TAKEN FROM SURVEY DATED SEPT 18, TEST HOLIE DATA SITE PLAN 2002 BY JOSEPIH A. INGEGNO LAND 1"=20'-0" ,. SURVEYOR ��� 2. ELEVATIONS ARE REFERENCED TO N.G.V.D 1929 DATUM 3. PROPERTY IS IN FLOOD ZONE AE (EL 8) FLOOD INSURANCE RATE MAP . 0�8C 1 �- Q 'Lo (A_A� DRAWING LIST SITE DATA LEGEND ABBREVIATION a v ' SYMBOL � DESCRIPTION SYMBOL DBESCRIPTION ------------ ------- ---------- ----------- ---- ------- -------- � --------- --- -- -- -------- ---- � SHEET NO DRAWING TITLE DATE SCTM# 1000-53-04-10 - - - -------- - _ SECTION SYMBOL I ______-____- -- ----- 1)e ar�me�n - _- -_ INT.--- _---_lntefl0f ------ _-__-- _ PR-------------Pair - w Z -A:F.� ---Above Finished CeTn ----- - - _ _ ---- -- --- --------- -- � DO(ORNUMBER _ g-------------- - - DST. DTL----- De i� KW xilowaft----- - UAL _-_-________ ua - Al TITLE PAGE WITH SITE PLAN 6.20.2006 / 1 \ SECTION NUMBER U i - -- - - ' --- - -- ------- ----- o _- o PROPERTY ADDRESS 1955 BAYSHORE ROAD,GREENPORT, NY SHEET NUMBER }- - - A.F.F. _ AboveTinished Floor _ __ ___ ___ DIA. tcU Diameter - - 1 _ __ ____Length _ -__- -- -Radius A A2 FIRST AND SECOND FLOOR ARCHITECTURAL PLANTS 6.20.2006 S to A1A American Institute of Architects DIAG. Dia onal - _ _ LAV. Lavato z ----- - - - g - -------------- - - - ry- - - - -------- REF -Refrigerator or Q W . A3 BASEMENT AND ROOF PLANS s.2o.20os PARZTITION TYPE _AIEE _ American Institute ofi Electrical Engineers DIM.,-DIMEN - - = Dimension- 16 # _ Pound_ -RE 'D-- -- Re uired q - MARIONAND JOHN BRANDVOLD AISC American Institute of Steel Construction DN __Down _ tll� Linear _ _ _ _ RM Sa--_-_____Room(s) _ M m A4 EXTERIOR ELEVATIONS 6.20.2006 OWNER __ - _- —_ -__ __ . -_---__ ELEVATION SYMBOL 0 _AL ALU�VL----- A1Un11nUm - - - -- - ----- pR( �----_ _ p00(�S�- ------ LT.---- Light. _ `- -----_-- - ���- i-Stal less tee-- Y _ A5 BUILDING SECTION AND DETAILS { 6.20.2006 -- ELEVATION NUMBER GYPSUM WALLBOARD AL . --�Iltefnate UfW . DWG Drawin - LOT COVERAGE SITE-16650 SF. --� — -------- - --- - — -- ---- ---- - - ---- g ------ ------ MANUF. ManUfiaCtUfe - - ----- -- SIM __$Im ar_ x A6 INTERIOR ELEVATIONS 6.20.2006 q �,p SHEET NUMBER 1 AMP:- Am ere - ELE�. - Elevation MAIL Material SPEC.(S�_ Bpecification�s) L m " HOUSE- 1976 SF. -- -- _ARCH.--------__-Arc steel_-- _ ___ ELEC. ____ ____ _ Electrical__ ____ - ___ __ MAX. ________Maximum _____ __-__-_-_-__--- ---- p�� -__ _ -� � o .� A7 FIRST AND SECOND FLOOR ELECTRICAL PLANS 6.20.2006 LOT COVERAGE-12.8% I �' ME7TAL __ ASHRAE- _ American Society of Nealing;Refrigeration - ENG. Engineer _ _ MECH. _-_Mechanica-1 STD_ S andard- �- a m S1 FOUNDATION&FIRST FLOOR FRAMING PLAN �-- &Air COndltiornng Enlneers E . Equal MEZZ Mezzanine -------- - — DETAILFLAG SYMBOL COIWCRETE(SECTION) -_. - - ty -- - q -- _- - ---- - ---- STL--- ---Steel co W S2 2ND FLOOR&ROOF FRAMING PLAN �i$M American Socle of echanicaI En sneers - - E UIP. E ui tent------ MIN - Nlinlmum _ _ L� --- - - - -- p ----- - -- --- _ - _-- STRUC_- Structure S3 STRUCTURAL SECTIONS&DETAILS ZONING R-40 DETAIL NUMBER ASTM- ASTM American Society forTesting atenals = C-- - Elecfric Wa�erCooler MISC.----- Nfiscellaneous _-_- EL - Tele hone w Z - p SHEET NUMBER ROLUGH WOOD BLOCKING BD. BOafd - - - EXH Exhaust - -- MTL -Nlet81--- -- --- - ----- -TH.THK_ �Jhicf%Thlckness----- a I �i sEc,T�oN) -BLK:- ___ Block- -------- --- -- ------- - Dt1ST.- ----Existing -- -- - -N - --- -North-- - ___ SURVEYOR JOSEPH A INGEGNO LAND SURVEYOR —__ BM. Beam IXP Ex osetl IVEC National Electrical Code nP -_T�ypica(__ 1380 ROANOKE AVENUE RIVERHEAD, NY ------- ----- --- ---- - - A- ---- _U.L llnderwrltersS Laboratories a WO(OD BLOCKING -B.O. - y Others FlN - Finish---- -__ - NEMA----National ElectricaTManufacturers AssoC. U.O.N. Unless Otherwise Noted SEPT. 18,2002 P� BOY. Bottom- - __ - - FL F__LR: ------T000r___ N.l.C:-_-Not in Contract tsE(crioN) ---- - _ _-- ' ----- -- _ ----- _ - _--_ --__-- VCT----_ --- -.Vinyl Composite Tile___ ALLOWABLE- 35 FEET• 3 COLUMN LINE -------- --- _BTU. __--_BfItISh Thermal Unl�- _— FT. -Foot-------______ __ NO Number - ( -Tile----- - COLUMN Ve ica _ BUILDING HEIGHT _CAB. ____Cabinet - -- _____ ____ __ ___ __ _ -FP. --_Fireproof=-- ___ N.TS.------Not ToScaTe--------- - --- _ 11.LF-____ Veri in Field 0 FINIISH WOOD CLG Ceiling -- _ FIX.- Fixture - OA -----Overall ------ VOL ___-Volume__ ---- ---- --- - - --- --- - - - -- --CER. _ -Ceramic ---- ---- -- FTG _ -_Footin ------_ OAD-___--_OveraII Dim_ ension---------- g W_.___-_ Width,Wide--------- ENERGY CODE BUILDING EXCEEDS MIN. REQUIREMENTS SET FORTH BY N.Y. I �- _CFM ________CubicFeetPe�lVfinute ____ GA. Gauge � ___ O.C.__ __On Center _ __-__-- _yy _ _ SI E PL. & TITLE BLOCK r, -;--, - ---- -- -GAL -_ Gallon -- -- - OD Outside Diameter---- - STATE RESIDENTIAL BUILDING CODE-SEE ATTACHED REPORT .' - PLYWOOD(LARGE SCALE) CL,Z Centerline _ C Water_Closet�____-- - ELEVATION MARK ---— - --CL - \� —Closet --- _ _GALV _Gaivarnze(>- _____-_-_- _ _PCF------ Pounds Per Cubic_FooT------------- -CLR. ---------Clear---_ _ _ _ __ GC _general ContracTor PERP_:_____ - Perpendicular= ------------- -yy p Wood DESIGN CRITERIA I - __ _________-- _ TYPE OF -WOOD PLATFORM FRAMING-DOUGLAS FIR#2 NEVW WALL _COL ____ -__Column __- _ _ GWB - �G,Ypsum Wall Board- ___: _PH. _-Phase_ _________ SNOW LOAD-45 PSF. CONC. COnCre e - _- _ _HDWR 118fdWafe PL --- -Plate T' Water roof___. \ \ \. __CO - - - - -- ---- - - --- ---- Wel FIRST FLOOR- ILL 40 PSF. Q \ \ \ NST. COnstruCEion H.M. �loflow McTal PL.LAM Plastic LaminaTe ,.. SECOND FLOOR-LL30 PSF. EQUIPMENT NUMBER EXISiTING WALL - - --Horizontal - _. _____ . __- - _CON�.----------continuous- __ ___,_____ NOR_IZ_:_ -Floriz_o_n_tal __ PLMB- -_-_-_Plumbing ____ __ WIND SPEED- 120 MPH. - - -- - �OPG_ _ _ COvefing -_ - - — HR _ -HOUf — _ __ _ PLYW_ D Plywood _ - FROST LINE DEPTH- 36" ___ __ _ y ------ REVISION SYMBOL � - - - - - DEMIOLISH WALL _CTR - � Center of Wafer �NL - -Panel -- SEISMIC ZONE-B — _OU FT Cubic -et l.D. -Inside Diameler _-______ POL_ _ -Polishe ___ _ 7Al WEATHERING-SEVERE X _CU1N Cubic Inch- _ 1N-. _ —inch _ PSF - -Pounds per Square Foot -- 7-' TERMITE DAMAGE-MODERATE/HEAVY O WINDOW � Y� 5 INSIULATED WALL -CUYD CubicYard-- - - -1NCG ---lncluae7fnc u i-1 d ng- _ - -PSI_--- - founds per-Square Tn�_ DECAY-MOD/H VY I _- Depth -INFO. ___ Information_ PTD. _ Painted_- - ICE SHIELD LINDERLAYMENT REQUIRED DBL_ Double _ _--_ _ 1NSUL Insulate Insula iing,TnsuuaatiOn_ _ - Y I. 16' 11'�2' -3r-0 4'.0' 5'2#' 4'-0' 1'-92' 'i 4x4 POST,TYP. r— DOOR SCHEDULE WD.RAILING NAME TYPE SIZE (WIDTH x HEIGHT) COMMENTS 3k 32' 32' _ D/F 3'-0 "x 11-9' 2'-8' 4'-102" 2'-8- - 102 E 6'-0'x 6'40 FAYNVFDERSEEN 1400 ---- - ,/ ---- — 6 20 2006 PRICING - - - -- I - --- 103 E 6'-0'x 6'-10 g�' �NH RSEN 00 5.25.2006 PROGRESS _ -- - 10q g{�•x 6,g• 45 Mi ��w� 0104 2006 PROGRESS -- -- -------- ----- ( 2 6�0• - ---- - -- --- 07/29/PROGRESS N N SCREEN PANELS- 105 A 2'-0'x6'-81 i I , � o I SEE PROJECT PROJECT MANUAL - 106 A 2'-6'x 61-8' 107 A 2'-8'x 6'-8' INSULATED SCREENED PORCH I 108 A 7-0'x 6'-8' 71-11 5--9. J 32' 32 -0 I j 109 A 5' 'x 6'-B' PAIR .r I E EQ. 10'-92 DECK' 110 A 2'-O"x 61-8' Q. 1, � 6'-1' �, I � yp - j I iii F I 3'-0'x 61-8" 1 In WD.RAILING `i a 1 201 A 2'-6'x 6'-8' Ni LINE OF f-V KNEE _� c� WALL ABOVE !� 202 A 2'-6•x 6'-8• �— - - — — 203 A 2'-8'x 6'-8' °Q' 1 r4' � I 7 j 204 A 2'-0'x6'-8' -� — — — — — — - `' -- -- --- j 205 NOT USED 206 A 2'-8'x 6'-8' LINE OF ROOF TE RI CE i ABOVE N T2 E 208 A 2'-4"x 6'$' -- LINE OF 209 A 5'-4'x 61-8' 1'-6'BIFOLD WALLS BELOW 210 A 3'-0"x 6'•8" 214 Z-_( - 4 62 4-02� y_ - 15'-11' - j j v' 211 A 2'-8'x 6'-0" 52' j 212 A 4'-0I'x 6'-8' PAIR M�""� Z - - 213 E 6'-0"x 6'-11' ANDERSEN 400 FWH60611APLR E 6'-0'xt6'-11'AV NDERSEN 214 I-/B 2 2'-0'x 6'-:11'SIDELIGHTS FwHsoslvJ"LR �y In DOOR TYPES - ---.---- �� O — - - � nLo MASTER BEDROOM B - --.�\\ \ \ I I LIVING/DINING 51: NI _ - j Li (v� 14'-10' BUILT-IN , CABINETS 2 A6 _ o 14_10 ` ' 51 1 27'-0' -- A e C D E F cc1" JELD-WEN ANDERSEN SIMPSON SIDELIGHT SIMPSON ' \1 'ATHERTON' 216115 VIEWSAVER SIMPSON VIEWSAVER SMOOTH THERMAL SASH VIEWSAVER THERMALSASH W e - - FINISH, 7044(1-G) THERMALSASIH 4246(I(i) ■ 7 SOLID CORE 7702(I-G) it 2 I -I - ------- , jO v 42" ! ► , I j -LINE OF HA yNALL 204 201 ,10, b M� TER BATHROOM I I r FOUNDATION a g I '� BILCO ENTRANCE I I ` REUSE WALL I N M _ �I ! --REUSE EXIST.DW EXIST. --- N' Q ' 5�. 202 3 ' 52• M I r i i COOKTOP ABOVE LINE OF FLOOR _ (� M m f I �I 1 6 �- >11� I - — �Al_.�C 1�J I KITCHEN I b 2 A6 4 i A6 7 ''nn uJ n �VI I CLOS .� - f i _ REUSE 3 I g t DV I EXIST.WALL I -- - OVEN 207 I G- -�- N. 206 II M I REF i U WINDOW SCHEDULE NAME TYPE ROUGH OPENING SIZE COMMENTS M j OVE - • j, 71 (� - - A 1 AN31 3'-0 i'm 1'-9" • �I' — - �,( I -- �/ �r i �_. 2'-0�f-_�'i 4'-0�—_ � � ly ---- 12'-10" 5 ' - 4'-0' \\\\� HALL t_ -LINE OF 8'-0" OUTSIDE I �\�: I 106 A6 I i i B AN281 2'-8 x;1-9 j I CEILING SHOWER I L y �� I 52' j I C CXW135 3'-0 x 3 50 ' i / I I �---I '"v ENTRY (�_ I ; " �_ BEDROOM#2 ` / - --- -- Fo „ �\ �D --- D I CXW 155 2'8'x'5'S�• 1� j IN, CL �� I� -- - AN51 5'-0 J')x 1'-9- .� ti w ._ ilo // MECHANICAL E I . _ _ F P5055 5-0 x.5 5 G i+� � ,,r, DUCT �\ _ ALL BATH I 1 I a � M — -\\ 108, j j G CXW 14 3'-0 'x;4'-0 • D MECHANICAL DUCT M SKYLIGHT( O'x22") 111 I -— -_ i__ __ _ T1 AFFW601 5'11 j'x(1'-9 A' ARCH WINDOW �j �. I � Upl IUP / 1� 0 32' � \ (109) a, T2 FWT-2-60110 6'0'x 12-10 ' 32 r-� /-- I 210) I i �� T3 ELFW6006 55 11 "x(3'-1 CIRCLE TOP 10'-1�" 3'10" �� g■ 4' - ---� 5'= -j -- P.T.WOOD PLATFORM AND --_- 8-0 PLA LIN. •d - — —�? 51. i7 I STAIRS \ HEIGHT— r, CLOS i� CLOS 1'32' I GARAGE - --- - 212 - 2111 I J j! 5/8'TYPE'X"3/41 _ ADO HOUR FIRE RATED ' C) A) GWB ON WALLS AND j 11 CEILING i j j I q DEN ;�q,, m z �� C 6'CONC.SLAB W 6x6 - j cv I --- --- ti 10/10 WWM ^ r b BEDROOM#1 l o REINFORCED,TYP.ON 6 MIL lT Q v w m I 1 -H POLY VAPOR BARRIER —i; 7 Ij 52' L 52' I - - �`' 12'-02' / 14'-0" - ` 14'-10' V I V ! I c m ~ 10 a 21 I I j 1021 I T1 I 13-2x4 POST / — -- w ao 1/2'EXPANSION \� JOINT*PERIMETER LINE OF' PATI FOUNDATION o ( TERRA j WALL BEELOW -- -- -- ----- -- -- - --- I- --—� 1st.+2nd FLOOR LINE OF 1'V KNEE EQ.- EQ' L- — --- - WALL ABovE -- — - ---—_ _--- — -- � —J PLANS 15'-9' 6_1' T 2T-11' - - - - - SECOND FLOOR PLAN y 13-2'- --- --,), - --- ----- - 14'-�' �. FIRST FLOOR PLAN 1/4"=1'-0"2 -- --- - ?T-1i�------------------------ , 4"=1'-0" Ti N _ I-- - - - --- m •N y LINE OF SCREENED 5'-5" �5'-5= , 5'.5' 2 ' PORCH BELOW ( - - -- - iL 6x6-W 1.41.4 WWM ROOF BELOW 4'poured concrete slab •° 8'poured conc.foundation wall j \Expansion joint and joint sealer 8'PC FOOTING 6.20.2006 PRICING SLOPE:3:12 SLOPE:3:12 —� ------------ 01 PROGRESS 25 2006 PROGRESS LINE OF ion _.-- �I -- . ,� O� � TERRACE BELOW I •b to OF __-- ;;.4 I Comp actable Granular Fill o O O a ' I 6 Mil Poryethene Va r Retarder 0D ,' 3I " �—REMOVE EXIST. Im z! 16' 35-2j �� DECK 0, (3)No.5-60 ksl Rebar —� — -------� �. - >- � —r+ TA' :11'-1' DRYWELL 4"PERFORATED PVC PIPE WRAPPED .;ry 5'6 ' d■ 4'2 ' 71-9■ I IN LANDSCAPE FABRIC co — _— - - ��-8x16 VENT - j CRUSHED STONE 8x16 VENIT CRICKET REMOVE EXIST. ! I , FOUND.WALL SLOPE:10:12 SLOPE:10:12 SUMP — — — I I �� — --� PIMP �;• i._ PERFORATED PIPING DETAIL I �i-- SEE DETAIL op ❑ • BOILER 12'-6• 0 Elii _ a IFRENCH I W DRRAIN a) W rn rt � EXIST.FOUND. I WALL TO BE- REMOVED. -� 12'-6' 7'-0j' 7'-0j' I, ' — j Z co I ; j LINE OF WALLS BELOW V 0 I I (o to61 SLOPE:4:12 j SLOPE:4:12 � . ''nn b I 5 rUP - t --t-- �; �! u! I, I 1 b C) SKYLIGHT N I �_ _ ----=_- co i I ------- —� ri ELECTRICAL -- PPA ELF R — S�OPE'412 j I FUTURE i N I II I 4 ruENERATOR I rni ID �? I I SUMP PUMP R'PLT I' I &0 RI 01 — - —i - SLOPE:10:12 i 7--� --------14-1------ -'=,-\'- I .\ EXIST.FOUND. I M I I I -CRAWL SPACE WALL TO REMAIN j _C14 � ----- ------ - 1 I w� Z 1 7 / « o j `i -- - ------- - ---- z - --- ------ - -- --- I- I a W j I W 1+f UNEX(CAVATED - -- - ----- — -- -- -- o ~ - � AREAI Y t m ► I j J U o e► poo Li — N — I— -- — -- -- --- --- -- --- - -- ---JI --------- -- - - - Tom' � 2-1. - 9,-0' --- � 2'-1' � 14'-9' � _ 13'_2" Ole 14'-9' � BASEMENT&R00 J' 2'—'-11' -- , PLANS 2ROOF PLAN FOUNDATION PLANA 3 1/4 1'-0" 4n=1�-0n JEjty ASPHALT SHINGLE ROOF C ------- -- — --- -- -- — - ---- ----- \ 6.20.2006 PRIG MG 5.25.2006 PROGRESS C>_ 01-04-2006 PROGRESS / — 07/29/2004 12 - 12 ----- - 4 ,-- 4 -0 PLHT. 8'-0"PL.HT. / / - CEDAR 8 - ---- ----- - - - -- ---- SHINGLE / n3 \1 SIDING _ -12--- _ -- - 10`/ 12 10 G G G 80! l { 12 - -- I i CRICKET CID �i0 WD.RAILING ---- - -----__---- _ - - -- ------ - 12 2'kneewall 12'kneewall -- ---- - ---- - _- -- AND POSTS -- �3 - -. - - ------ - 3 --- -- -- --_- ---- .� Q 'SECOND FL - ECOND FL -- -- — -- - -�►- �- __-- ----- - - - ------ - ------- ----- - ------ - /;)O O O\ © = �J \ �.l I 1 7 - I •�'t'v.�' I r"F�!'f ,��#`r r _ .��,ryn� � � I i ,y` I � r ,.F fr'�'r'r,�i'' I ' ,,-< .A � _ © © © `'f' �� � �I / �1 �\ x�'% A'� l "FBI Q CEDAR _ !•s','s. der. �''"X` "�� •'.r j U I �J OD 4�"y !I' SCREENED c' SHINGLELi OD O I a "� �, r f. ,� r 9 r �' ! j �• F y . j alx' PORCH • • `\ �` SIDING if 5 1- T�� f I I � II WOOD ! II' II �i Ii A4 ufl I 'I,.Ii I I �I d`. ' .I I r RAILING O 11 - if ST FLOD I __ L I.1'�lit _ aRST FLOOR _ I I! i! I i I I I !! I� II I _ _- - I:L,._.l 1_ BIL Y -- -=- -- L I - _- _-----.----�- - - - ---- - --------- O ENTRANCE Z -- 1x4 LATH�` W NEW GRADE 4 =-.=_-_- _= ------ NEW GRADE EXI rr��� hj EAST ELEVATION I NORTH ELEVATION �N�y n=. n LL 1/4 1-0 WINDOW SCHEDULE il ! I ! I W NAME TYPE ROUGH OPENING SIZE COMMENTS I I A AN31 3'-0 J'x 1'-9" i � REMOVABLE FIBERGLASS 0 B AN281 21-8'x 1'-9" I I i I - I SCREENING ALUMINUM FRAME 1x3 PANEL FRAME I C CXW 135 3'-0� x 3'-5 f =-- -- ----- ---- ---- _ (/� ------ - ---------- "/4 x SILL V I D CXW155 2'-8'x 5'-5 -1x4 PANEL E AN51 5'•0 J'x 1'-9* -- � —- ---- - _--_� - -- M� l W F P5055 5'-0 x 5'-5 I RBS 12d2311PANEL MOULD G CXW 14 3'-0 'x 4'-0 Tl AFFW601 5'-11 J'x 11-9 A' ARCH WINDOW 3/8'MARINE(PLYWOOD LI! Lo T2 FWT-2-60110 610'x 1'-101' T3 ELFW6006 5'-11 "x 3'-1 CIRCLE TOP SCREENED PORCH DETAIL r- ASPHALT SHINGLE ROOF /-LINE OF DOUBLE SKYLIGHT SHINGLE LAYERS (30 x22) 1 �' �- T i WD.RAILING AND POST 12 8'-0'PL HT - -- -�--- I` ' ' III I' --`� �\ �•-------- I it - - --- \ 10OD ch a A LG Go if -- —.— — —+— -- QI --.— ---- — 7� — --- -- 10, - -- -- --- - ---- - - ----- - — -- - I T r---- — --- �—� -- -- -- --- —-- —--- < uj1s. ---- - -- - ------ --- — - --- -- - q o • 12'knee wall 3=' — - - — - -t -- 10 ---- ------ - _ ---------------------- — --,--------------- ----__--- � � 12'knee wall - -- -------------------- — - -- --- ---- -- --- — SECOND FL - ---- ------------- --- - - - ----------- - ----- \ S s ---- ------- -- ---------- O --- --_ -�-- �-------------------- �. ------ -- ------- -- --- U — Y �- 1 (I �_ oc �? �-� n j I --- -- ------ ___ ►- CC CEDAR SHINGLE SIDING �102) ` _ f � ! - ----- -- ----------- - BI \. - --------- f---- -- --- �' ENTRANCE �J -- 103) �-<,� ---- ---- f ELEVATIONS FIRST FLOOR FIRST FLOOR rE - _-_ - \ i — - - -- - - /t — ------ - -- -------- —I I I J [FANDMSMTjYINDERSEN NEW GRA 2873 ,-2a33 I I . c _ 1 NEW GRADE �L--- ------ ---- --- - T - EXIST.GRADE � - _____ - �- _ - - - - - � - - - - - - _ __ - ` - - - � - - - - - - - - - _ -- -- - - - - - - - - - -- - - - -- - - - EXIST.GRADE 1x4 LATH 1x4 � --- - - - - -- - - -- --- ---- -- --- -- - - -- -- --- OUTSIDE SHOWERJ A 4 WEST ELEVATION SOUTH ELEVATION ix6 TRIM BOARD \\ cl;`� PLATE HEIGHT SECOND FLOORON 1�6 FASCIA \--2X4OUTRIGGER ass.2ooePROGRas — — 01-04-2006 PROGRESS ALUMINUM FLASHING ' ELM 5/8 CROWN \ BEADED BOARD SOFFIT 07/29/2004 �,. 1x FRIEZE �\ ASPHALT ROOF SHINGLES ON 15#BLDNG PAPER ON \ 1/2'PLYWOOD SHEATHING ON 2x4 RR 0 16'O.C. s � 0 FINISH DECK SLEEPERS \� EPDM MEMBRANE FIBERBOARD UNDERLAYMENT 3/4'PLYWD.SHEATHING TAPERED JOISTS SCUPPER �— ALUMINUM FLASHING <.�_ ��•..�-- ._.. _,.� 1x 6 FASCIA g Ao' 2X4 OUTRIGGER 3 — -- E Z 3 , Z w a , SECTION DETAIL @ PORCH DECK ! �� 1"=11-0" Ur CONT. RIDGE VENT fV \ SECTION DETAIL @ SOFFIT w TYP. ROOF CONSTRUCTION:_— \ '� _ 1 _n-1�-On - �.- ASPHALT SHINGLE ROOFING ON 0 15# FELT ON 5/8" PLYWD. T SHEATHING ON 2x12 RR @ 16"O.C. d4 r/y 12 \ \� 12 VJ 4�� - 6• VENTILATION ", t A F /, x x\ ), ", {^) t k 'x �X L GAP WITH - - � --- -— ---- - - �' ��. - _ INSECT SCREEN �� 8'-0"PLHHT. - �, 8 Aft — — SOLID CROWN 12 �1J R38 C BATT. 12 / 7 PA �------ lx6 FASCIA 10 INSUL { \� -- \---� _, --- �'� ---- \ 10 BR. # 1 \ 2x4 OUTRIGGER SIMPSON H2.5 A - HURWICANE CLIP @ 16"O.C. r o C \ 6'-0" KNEE -1 WALL 00 4 BEADED BOARD SOFFIT SECTION DETAIL DORMER 11/2 -1-0 1'-0" KKEE WALL SEG'OND FL .—.- t"fr-,�{Yr YY{z Al r"YYYA"Y'{Yl'v_]"_,-.-r-rl'r`ir — _ . Y 1 Y ti) t Y r j'Y 1 . r t v 1 t r v t Y r 1�1 r Y v , r 7 ti r Y , r v , Y 1', . Y v . . v i r. t r Y-v v r . r Yr,Y Y , _rt_2'-6" —DOUBLE SHINGLE LAYERS � SEE ELEVATION APA RATED PLYWOOD TO /" li_r TYP. EXTEND TO TOP'OF TOP PLATE R-21 GATT.INSUL. PROVIDE 8dCO)MMON NAILS \�R-21 --------- - o EXTTERIOR,EDGE BATT.INSUL r K j OFALLLSHEATHING �!�- W z } V o r z p 4 Q W m W 0) I QY CAD N - I � `' ~ a`"D GARAGE I, � DEN _ TYP. EXTERIOR WALL L m CONSTRUCTION:CEDAR J SHINGLES ON 15# BLDG. PAPER ON 5/8 PLYWD.SHEATHING ON W 2!x6 WD.STUDS @ 16"O.C. °` W/R-21 BATT. INSUL 5/8 °1 z FIRST FCLOOR DRYWALL TAPED AND SANDED _ _.--- -.- - - -___--_ -- — _ - -- - ---------- - - ----4 —jr- "Y'rV , v iY fYYrYY�rYrtiYYYY �'r YYlt' 'r'Y tY1"x'YYYY'Y'r� YYYYY 'Y� 1Y �� r /r. r 1/2" EXPANSION 6 \ ' SEAL @ PERIMETER CRAWL SPACE ISECTION&DETAILS GRADE E6"MIN. BELOW TOP OF CONC. SECTION DETAIL @ RAKEA 5 BUILDING SECTION ji. 3/8n-1t-0n SEE STRUCTURAL ION FOR CONNECTION DETAILS '7 -- ALIGN- 4 {{ 1 - - I 6.20.2006 PRICING 15.25.2006 PROGRESS 01-04-2006 9 2004RESS 07 / / I jll i i I \ \ / 0 0 0 10 o I �� 1'-0' .\ o O o 0 01 o o o II - ------ - -- L � \ I � CABINETRY BY OWNER VCABINETRY BY OWNER ZLIVING ROOM -WOOD BASE EXTEND TO 1KITCHEN UNDERSIDE OF WINDOW SILLS. WOOD HANDRAIL PAINTED BALUSTERS —PTD.GWB -PTD.GWB ;�, PTD GWB\ Ti\, II I I I I \ LL. IT F�j - PTDGWB - - - rN -- - _ - -- L----- -- I' I j TILE BACKSPLASH III II / l OPEN - - BY OWNER i jl ------ W t --- --- - OPEN-- - I, hj • -' I ALIGN FACE OF_ 441444+ --i - --_- - _----G - - - BASEBOARD W/STRINGER I \ I o 0 0 0 —EQ-- --Q--.r y—Q—,� WD.BASEJ CABINETRY BY OWNERZ 3 I KITCHEN — NEWEL POST /4 4 STAIRCASE r 9 STAIRCASELo m Lo / 0 I I� I EXTEND WINDOW CASING TO WALL,TYP.OF 2 -— --- — - ------- NOSING-—--- ---- -WOOD BA Ix TRIM I' --LANDING 7-7- --PTD.GWB ---- rn ' I I III, i r ----- -- PTD.GWB--� w m r II I I I I lip I f ' II I v INT. ELEV. I I I i II J� I i 5 STAIRCASE 6 STAIRCASE 8 STAIRCASE 7 STAIRCASE 1 \ UP LEGEND Fop A EXISTING WALL j I DEMOLISH WALL NEW WALL � - - - - - - — - INSULATED WALL 620.2006 PRICING 4.6.2006 REVIEW I I it I ,I I � i I FIXTURES TO BE -- -- -- — — — SELECTEQ�\ 1 \` — — UWDER— —� — -- r r- L- OTION 1 I �}{ � / FLOOD I I I (`Inp- I \ \ ---- / Z / PENDANT j WIRE FORhj ❑ I II QT11 ( i FUTURE FAt� LL 'F+'COORDINATE r I I Z L0CATAON I1 W W/OW�ER I \\ ui +42 t —I`—�� i I' — UNDERCOU \ '�\,��.r �I I Q \\ \ I I PE ANT ! i I m LIGHTS \\ IPQ Z I Q +42-- rPiz — cL / REF -- — / Up,11L� I \ 1\ i ILHI IMP ELECTRICAL LEGEND — \\; DUPLEX RECEPTACLE OUTLET / I QUADRAPLEX RECEPTACLE OUTLETMIRCEL I I (o HALF HOT RECEPTACLE OUTLET' ! \ f OCKETEIN WATER PROOF RECEPTACLE OUITLET \\ �Fl GROUND FAULT INTERRUPTOR(OUTLET HIGH HAT FIXTURE J DIRECTIONAL HIGH HAT SURFACE MOUNTED CEILING FIXTUREPORCEL SOCKET I I SURFACE MOUNTED WALL FIXTIURE r -+ r SWITCH �!j ,' 1 I m z DIMMER SWITCH I � TELEPHONE I W TELEVISION ? r I I \� SMOKE DETECTOR SURFACE MOUNTED CEIUNG FA4N \� / r m THERMOSTAT \ SOCKET -{�-SOCKET UNDER CABINET MOUNTED FIXTfURE I T" _- _ - W FIXTURES TO BE I i _ __ 7 I � W � SELECTED '\ I —T SURFACE MOUNTED LIGHTING 1TRACK \ _ I W N `W z EXTERIOR WALL MOUNTED FUMOD LIGHT __- _ ELECTRICAL PANEL ---- 1 L EXHAUST FAN/LIGHT I ___ - - - - - - - - -- - - - — - - \ � - i I MOTIbN FLOOD — 3 WAY SWITCH � -- — -- -- -- -- ------ ---- — � I ELEC. PLANS SECOND FLOOR REFLECTED CEILING/ ELECTRICAL PLAN ,na FIRSTFLOOR REFLECTED CEILING/ ELECTRICAL PLAN NEW 12"P.C.SONOTUBES 3-0'BELOW 16 Notes: GRADE,ON UNDISTURBED SOIL,TYP. 8" " 1(3) 1.75 x 11.875 LVL The contractor is to verify all measurements in the field and any discrepancies are to be brought to the 518"!?1 Bolts C attention of the Engineer prior to construction. BIGFOOT BF-24 P.C.FOOTING 2X12 ACQ STRINGERS @ 16"O.C. ! -I - - WITH 8"0 SONOTUBE 3'-0" CONNECT STRINGERS TO i !t � B 1 - All concrete 3,500 psi after 28 days minimum. 13ELOW GRADE,ON GIRDER WITH SIMPSON - ! S-3 UNDISTURBED SOIL 1 —I- - 4- I � � 2-All rebar ASTM A 615 Grade 60. HUS26 JOIST HANGERS _ 2/" - - 3-Footings are to be installed on undisturbed virrgin soil.The bottoms of all footings are to be installed 5" 5" 11" 1t" - 22 - - - — - —�- - - �— - il I � - - - - � I- - - - t r" - - - - t, !1 L -I - - - - - - - � • � a minimum of3'belowgrade. ACQ(2)2x 0 R ! 2 1/2 A36i Steel Flitch Plates a 4-The Engineer is to be contacted if unacceptable or questionable soil is encountered during ACQ(2)2x10 RDER ACQ 2 2x10 GIRDE " � I -� - -J w 1-J ( ) J - �t !� ( ) 3/ excavation.Unacceptable soil is soil containing clay and/or organic material. 0-1 `o' LUI I I `o'I o FLITCH BEAM DETAILS 5-All snap off form ties are to be removed and rremaining openings are to be sealed/grouted. b 1 (2)2X4 COL.ABOVE I BIGFOOT BF-24 P.C.FOOTING _ WITH 10"0 SONOTUBE 3'-0" ) I SCALE 1"=1'-0" 6-Backf!II along foundation walls is to be clean material and is to be mechanically compacted in 6" U 4X4 COL.(TYP.) Q BELOW GRADE,ON C3 j lifts to 95%of maximum dry density. 0 I _ ci I UNDISTURBED SOIL ACQ(2)2x10 GIRFEER r 7-Rebar installed along the top of the foundatioin walls without windows are to be installed 10"below the top of the foundation wall,Rebar installed alo)ng the top of foundation walls with windows are to be t - - - t' !- - - 10 - ER - - - - - - installed 3"below the bottom of the window L JACQ(2)2x10 GIRDERL - ACQ(2)2x10 GIRDER - _j ACQ(2)2x10 GIRDER �- - !--) openiing. o I I 4X4 COL.(TYP.) �I ! 8-The foundation contractor shall coordinate witth the plumbing and electrical contractors relative to BIGFOOT BF-24 P.C. I 00 0 SEE STEEL COLUMN BASE PLATE o) ! °' FOOTING WITH 8"0 o iv o I AND ANCHOR 80LT DETAILAT installation of sleeves and other penetrations priwr to pouring concrete. SIMSON HUS210-2 - I o SONOTUBE 3'-0' SIMSON HUS210 2 FOUNDATION CORNER I 1" cv I • I JOIST HANGER cy rs BELOW GRADE,ON JOIST HANGER 3.5"X 3.5'X 1/4" x16 VENT 0I �„ HSS 3.5 x 3 5x 1/4 9-Install isolation joints along foundation walls a)nd at column and other floor penetrations. UNDISTURBED SOIL I STEEL COL.ABOVE - P- FK­7 �s LJ3- "0 Anchor Bolts Q - - - ACQ-20D-LEDGER_ -- - I ! e ! SIMSON LUS26 - - - -- = __- - ! 2„ 10-Installed contraction joints in the cellarfloorslab every 18'minimum. JOIST HANGERACQ(2)2x10 GDR. 4-8"0 Anchor Bolts3 2X4 COL.ABOVE HSS 35x3.5x 1/4 11 -Foundation excavation is not to be back fillecd prior to the installation of the floor framing. O rsSx16 VENTSIMSON LUS26 .5"X 3 5"X 1/4" 2" HSS 3.5 x 3.5x 1/4 co ACQ 2x10 LEDGER ! I EAM POCKET JOIST HANGER STEEL COL.ABOVE ! I 11 Z"x 11 Z"x 4" _ 2" Slab Site Preparation ! ! I Base Plate 2-1 0 Anchor Bolts 2" 2� B. 2x8 C D ! *The area where the slab is to be installed is to be excavated to the necessary elevation to meet the - - (3)2X6 COL.ABOVE- I �� @ 16"O.C. ( ' I I �'"JLiI I final top of the slab elevation shown on the Archlitectural drawings. (3)2X6 COL. Cl 1 I j_.iL ' A I I ^ 7° ! � I ABOVE I w l S-3 — — *The areas where the slabs is to be installed are to be Proof Rolled in accordance with ACI 302.1 R. ! M I I I I The Engineer is to be notified if unacceptable soiils are encountered during excavation and if Proof 9-1/2"TJI 230 FJ @ 16"O.C. Rollin produces results that exceed ACI standards. ! • ! I 3 1/2"0 STL.COL. ON - � i o � g 2-8"x 2-8"x 12"P.C. v 1 I I I 11-1/2"x 7"x 4' �, I Base Plate I FTG. I I I � I ! ( I I The excavated areas along the stem walls and ifootings are to be back filled with clean material and ( ! I M I Q 1 j I mechanically compacted with clean fill in 6 inch lifts.Each layer is to be compacted to 98%modified _ SIMSON LUS26 proctor. .—. I -------� F I JOIST HANGER Base Material layer shown on the drawings is to be a compactable,easy to trim,granular fill that will ! " _ - remain stable and support construction traffic.A clean fine-grained material with at least 10 to 30%of 14'-1" ! articles passing a No.100 sieve but not containiin silt,or organic material is recommended. i - I (2)2X6 COL.AB P P 9 9 9 j I I i I I I I Slab Notes: -� � 1 31/2 0 STL.COL. ON I I I I j I 3'-8"x 3'-8"x 16"P.C. ACQ(2)2x10 —ICD *Isolation joints are to be installed between the slab and the walls. Use preformed joint filler that is to I I �� FTG. ,I I I Steel Column Base Plate and Anchor Bolt Typical Steel Column Base Plate and- Steel be cutYzinchbelowtheslabsurfaceandtheresutltingjointistobefilledwithanelastomericjoint 1 35"x3.5"x1/4"STEEL I� ; Steel Column Base Pate and Anchor Bolt sealant. ! 31/2"0 STL.COL. ON COL.ABOVE I I I ( 1c, Detail at Isolated Footings Anchor Bolt Detail I at Foundation Wall Contraction joints are to be installed as shown im the drawingsand are to be Y the thickness of the 6 ! 2'-8"x2'-8"x12"P.C. I I I Detail at Foundation Corner * j II; ! FTG I I la 1 ! Scale: 1" = 1'-0" Scale: 1" = 1'-0" p. COIslab but not less than 1 inch deep. (3)2X6 COL. o - n I Scale: 1 - 1 -0 (2}2x6 COL.ABOVE I_ (— — ABOVE 1 i — — L --I ! ACQ(2)2x10 The welded wire reinforcement is to be placed in the top third of the slab and is to be adequately 3 5"X 3.5"X 1/4"STEEL COL. �I(' SEE TYPICAL STEEL COLUMN F I I I j ! i o supported b recast concrete bar supports to assure that the reinforcement is held in position during ABOVE �� —BASE PLATE AND ANCHOR BOLT ! I - (3)1-3/4"x 91/2"LVL - ! LU a PP Y P PP p g DETAIL AT FOUNDATION WALL ! ! T ! j I x AC ! m o concrete placement and finishing. r " quip ! _T- 9-1/2"TJI 230 FJ@ 16"O.C. —I— II I 0 o M-- -- - _I - 1- - - - � ! ! I I , I � com `` I I I 91/2"TJI230FJ@16"O.C. r- T .7 I I ! w ! v o � w mo 3 1/2"0 STL.COL. ON I -'-' 1 0 o I I N W = 0 2-0"x 2-0"x 12"P.C. '- __1.: FTG. I j' =.. �. T �S 0 i { 31/2"0 STL.COL. ON I ( 5 a a. - 3'-8"x 3'-8"x 16"P.C. N I (2}2X6 COL.ABOVE FTG. I (2)1-3/4"x 9-112"LVL 3.5"X 5 5"LVL COL. I 9-1/2"TJI 230 FJ 1 41 C I I ABOVE t 16"O.C. x ! !IF' ! i 2x6 stud wall S-1 I j (3)2X6 COL ABOVE- ( -! - -y --- - 2X6 ! 2x6 treated sill plate I �A (3)1-3/4'x9-112"LVL N 1- ! ABOVE COL. ! _ - - - - - - - - - - - '�' - - - - - - ! 1 ' 2xsstudwau Desi nLoads: L.� - - - 9 z"TJI 230 FJ 16"O.C. 9 i , ! (2)1-3/4"x 9-1/2"LVL ! ! ! I j @ 2x6 treated sill plate (2)2X6 COL.ABOVE ! SIMSON LUS26 s"0 Anchor Bolts 3 Ft.0 C. i I� -Roof-Live Load-35.5 psf Copper Termite Sheild 1/2"expansion seal_ - JOIST HANGER �t - ! I N ! P Based on ASCE-7 and Pg=45 psf I - e'O Anchor Bolts 3 Ft.O.C. per Figure R301.2(5) ? 6x6-W1.4xW1.4 WWM 2X6 ACQ HDR. X' I l { o !, Termite shield&sill seal r� 1 '2x6 ACQ DJ SIMSON LUS26_ 2x8 AC D -Dead ih @ 16"O.C. `1 JOIST HANGER Q 16"O.C. � N9,, l I I ! 1 3 Grade 5"Poured Concrete Slab ACQ 2x8 LEDGER " D Load -15 psf __ ___ _._ __ - _ ._ __ ._ 9-1/2"TJI 230 FJ @ 16 O.C. -- - - -- -- -- V I '.` r rade -2nd Floor -Live Load-30 psf ! _ (2)2x6 COL ABOVE I '•:',` 8"min -Dead Load-15 psf 3 - -- -- - -- -- - - - ...- -- - - - - ACQ 2x10 NEW 12"P.C.SONOTUBES 3'-0"BELOW J II (3)2X6 COL.ABOVE ! ( GIRDER ! :: (2)No 5 Horiaonlal rebar-See Note 7 .•� .— GRADE,ON UNDISTURBED SOIL,TYP. ! ! ! •' II -1st Floor -Live Load-40 psf } I II M ! -- - - - Water Proofing ?fv i••iSi r/ YYw••3•�j•�M1 +:,�•r1�r :: (2,2X6 COL.ABOVE XIST.FOUND.WALL I NI rn 0 I .I ,"' t -Dead Load-15 psf � �� � ! TO REMAIN j .�w 0 ! I '' . c \\ \\ \\ \ 10 mil.vapor barrier �5"CONC.SLAB W 6x6 W1.4xW1.4 I co r'' Water Proofing r,, -Deck -Live Load 60 psf I I j t3)2X6 COL.ABOVE i �I� I__I_I M -Dead Load-15 psf WWM REINFORCED,TYP.ON 6 0 r (3)2X6 COL.ABOVE ! ( ! MIL.POLY VAPOR BARRIER I ! ! ( ! ! -!"�+t" I- o o 2"x4"Keyway \ \ I ; Y Y // �/ 4"Compactable Base Material (3)2X6 COL.ABOVE - �- -!-- L �� -Wind Loads-120 mph-ASCE-7 i I I ! I o �,:� �\ MWFRS-Method 2 CU Component and Cladding-Details from ! I I ! CRAWL SPACE �. I i ! I (2)No 5 Rebar 16' WFCM TABLE 3.8 00 A I I j ii 1 8"poured conc foundation wall 6x6 W 1.4x1.4 WWM Expansion joint and joint seal r Design Critteria-NYS Residential Code R301.2.1.1 and utilized t CONTRACTION JOINT ! ! i l 8"x16'°pouredconc.footing Foundation Wall at Garage Detail the methods and procedures stipulated in Chapter 2 Engineered Design and Chapter 3 Prescriptive Design in the American Forest l :i:r. B 9 P P 9! I 4"poured concrete slab ,; and Paper Association Wood Frame Construction Manual for One ------ --------------------- ;r ••� ,—.•s. ,.j`Y; 1 = and Two Fa I "'i'•N•I �.� Scale inch 1 ft. mi y Dwelling Units g and ASCE 7. j ri:Mr� ' :'✓' -High Wind Addition a i ! �'4r 1 z 4 i�.w tt4�• Z•V . �. r I I ! l i :.^.7!r!$i'.r+^.•.�:se,.w•�•1YiXw.1`t!ti,+i•ii'i .1'L.ra,Yr.{*•,.4:.•,r.t,Yt', ao 10 Mil Polyethylene Vapor Retarder ! ! 9.1/2"TJI 230 FJ @ 16"0 C. ! (3)2X6 COL.ABOVE i � � 16° (3)Na.5-60 ksi Reber (3)2X6 COL.ABOVE ! ! �� ! � ��i�' I i o I I ! Compactable Granular Fill GG o � I----(3)2X6 COL.ABOVE ! CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA ! � ; ; � ! � ! ! A Cellar Foundation Wall Details Ground Snow Load Wind Speed Seismic Weathering Frost Line Termite Decay Winter Design Ice Shield Flood Hazards 4 ` i I ( Scale 2 inch = 1 ft. Depth Temp. Underlayment fg1 Z c� (2)2X6 COL. I ; ! t I ! it ! � �_.. __. -_ _.. __ ..- ...._ _----- -.. -- -- -- . ABOVE_ _ __�� i I Required SSIa���" M (3)2X6 COL. __ —,_—._" I 45 psf 120 mph A Severe 36 in. Moderate Slight to 11°F Yes ABOVE - _ __ _ -_- to Heavy Moderate ��! (2)2X6 COL. (2)2X6 COL. " Condon Engineering, P.C, BRANDVOLD RESIDENCE ABOVE ABOVE Scale: 1/4 =1-0 1955 BAYSHORE ROAD Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education Drawn by:JJC 1755 Sigsbee Road G REEN PO RT, NY OF Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Mattituck,New York 11952 Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing (631)298-1986 Foundation & First the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or AW FOUNDATION & FIRST FLOOR F RAM I N G PLAN_ Land Surveyor shall affix to the item his/her seal and the notation"Altered by"fol lowed by his/her Date:6 15 20063 signature and the date of such alterations,and a specific description of the alteration. Floor F ra m I n g Plan Table 3.1 Nailing Schedule(Wood Framed Construction Manual 1995 SBC High Wind Edition,Page 110) Framing Notes: Joint Description Number of Nails Nail S acin ROOF NAILING The contractor is to verify all measurements in the field and any discrepancies Rafter to Top Plate(Toe-nailed) 4-8d per rafter are to be brought to the attention of the Engineer prior to construction. Ceiling Joist to Top Plate(Toe-nailed) 4-8d per joist Ceiling Joist to Parallel Rafter(Face-nailed) 8-16d each lap Wood Framing Ceiling Joist Laps Over Partitions(Face-nailed) n/a each lap ----- ------ ' 1 -All lumber is to be No.2 or better Douglas Fir Larch N with the following Collar Tie to Rafter(Toe-nailed) 2-10d per tie g ( ) g -----I Blocking to Rafter(Toe nailed) 2-8d each end minimum specifications: Rim Board to Rafter End Nailed 2-16d each end / ; I Fb=825 psi I (2)2X4 COL. / { ! WALL FRAMING Fv=95 psi i 3X8 HEADER t__—_.-__.__;--_—_—.____—___..__.__ ---.-_._-_�, Top Plate to Top Plate(Face-nailed) 2-16d(1) per foot Fc perp=625 psi I w -" " `-- r ; i Top Plates at Intersections(Face-nailed) 4-16d joists-each side E=1,600,000)psi IM, �Btii / jl I -nailed Face Stud to Stud( ) 2-16d 24 o.c. 2-All Laminated Veneer Lumber is to have the following minimum specifications: { ♦e / ��e �! Header to Header(Face-nailed) 16d 16"o.c. along edges W I Fb=2,900 psii Top or Bottom Plate to Stud(End Nailed) 2-16d per 2x4 stud ' I j (2)2X4 COL. Y I Fv=290 psi 3-16d per 2x6 stud IFc perp=6501 psi { 2x6 RR @ 16"0 C. 1 4-16d per 2x8 stud E=2,000,0001 psi I I: ! 2X6 COLLAR TIES i Bottom Plate to Floor Joist, Band Joist, End joist or Blocking(Toe-nailed) 2-16d (1,2) per foot 3-All beams fabricated with multiple Laminated Veneer Lumber boards are to be FLOOR FRAMING nailed/bolted in accordance with the manufacturer's specifications. I I Lu Joist to Sill,Top Plate or Girder(Toe-nailed) 4-8d per joist 4-All TJls are to be installed in accordance with the manufacturer's specifications o Bridging to Joist(Toe-nailed) 2-8d each end and shall include squash blocking and web stiffeners at bearing points on girders j I I (2)2X4 COL. _ I i; Blocking to Joist(Toe-nailed) 2-8d each end and other load bearing areas. - - --- --.- -- --. ----- .--- -- -; i Blocking to Sill or Top Plate(Toe-nailed) 3-16d each block Cl) i j I (3)2X6 COL. Ledger Strip to Beam(Face-nailed) 3-16d each joist 5-All straps,connectors,plates,bolts,nails,etc.are to be galvanized or stainless (2)2X6 CbIT. (2)2X6 COL. (3)2X4 COL. I (2)2X6 C L.ABOVE ABOVE ! Joist on Led er to Beam Toe-nailed 3-8d steel. Designated connectors,strap etc.on these drawings are made b Simpson (3)2X6 COL. j 3 1 3/4"X 11 7/8"L GIRDER :----- (3)t-I-3/4"X 11-7/8"LVL GIRDER W/(2)12"FP BELOW JOISTS ) g p g {3)2X4 COL.ABOVE I (� - _ __ �_-_-_ - 9 ( per joist y p ---_-.---_-----�..!------ -- ------- - - - _ - ;__. ,R`�_ -- - ,,.�; + :_ �,, . -�„` _�r; - . r Band Joist to Joist(End-nailed) 3-16d perjoist unless indicated otherwise.All connectors,straps etc.are to be nailed/bolted in -r o - -- -.. _._ - --- ------ --- --� - ---- ---- --- - ---- ! I' accordance with the manufacturer's specifications. D .- � --I - - m - - -_ - - - - ' S 3 a- I ; " \\\ 1� (2)2X6 COL. I p {3)2X4 COL. j i, -1I i Band Joist to Sill or Top Plate(Toe nailed) 2 16d (1) per foot � j l 3.5"X 3.5"X 114" ! I I II ABOVE j ROOF SHEATHING 6-All floor sheathin I!s to be /2 inch AC e plywood,tongue and groove,with an 0 9 i type p Yw 9 I I 3.5"X 3.5"X 1/4" I STEEL COL , 1 123 ! W I " 1 w I ; 1(3)2X6 COL. II `! I rEEL COL. `o I Structural Panels 8d (Detail sheet S-3) APA span rating of 48/24. Floor sheathing shall be glued and screwed to the floor - - - =I 2x8 RR !16 OC. cZS �P !---- - - !I I ! I 1Q0 I N E OF WALLS - - -I - - UJ -- joists 6"O.C.edges,and 12"O.C. field -- -- -- .- - - -- I ! i SIMPSON JOIST ! 1 9 j i j I e�� BELOW j (3)1- X 9-12" LVL GIRDER BELOW JOISTS (3)2X6 COL. 0 1 w !(3)2X6 COL. i - o HANGER LUS26 I 15 I N I I. I I N �1\e ; 1 1 Q I (3)2X6 COL.ABOVE i I I I 7-All wall sheathing is to be /2 inch APA Rated Exposure 1 plywood and shall be - i I 3X6 CR 0 ` i ( SIMPSON GIRDER TO ! ! nailed with 8d common nails 6"O.C.edges and 12"O.C.field. O I II I v �°�' j j j 1 I GIRDERHHUS410 `� I i i CEILING SHEATHING I) I ! j (2)1-3/4'X 11-7/8 LVL FLUSH GIRDER ! 1 i Gypsum Wallboard 5d coolers 7"edge/10"field 8-Solid blocking is to be installed every 8'max or mid span of all floor joists with ��• !, 3 1-3/4"X 9 12" LVL HEADER ! ! I (2)1-3/4"X 11-7/8" LVL SSH GIRDER I ! i yP (3)2X6 COL I (3)2X6 COL. I I ( ( (3)2X6 COL.ABOVE SIMPSON I x ( !I WALL SHEATHING g spans exceeding 8'. I GIRDER TO I I I Structural Panels " " GIRDER i 8d 6 edge 112 field 9-Double joists are too be installed below parallel walls. it 10 0�� i I I I I I HHUS410 I I 6-0"KNEE Gypsum Wallboard 5d coolers 7"edge/10"field 10-Blocking is to be installed at all point load bearing points. WALL =' w� 11 -Walls are to be framed with 2x6 inch studs spaced 16 inches OC unless M o FLOOR SHEATHING L • ! w 1 1 o I I! indicated otherwise. l ` I v /��;\° { to I �_I o l I !I Structural Panels 0 � 0) I�' (ABOVE 2)2X6 COL I 1 or less 8d 6"edge/12"field 12-First Floor joists are to be TrusJoist TJI 230/9.5"and Second Floor joists are o �I r° X i " to be Trusjoist 230/111.875 and are to be installed in accordance with the Y I ! I J (1) Nailing requirements are based on wall sheathing nailed 6 on-center at the panel edge. If wall sheathing is nailed 3 manufacturer's specifications. I n I LL " 1 11 on-center at the panel edge to obtain higher shear capacities, nailing requirements for structural members shall be 2x12 RR a0 16"o.C.! I t I i j ! j N 1 0 1, P 9 9 P 9 q xco 2x8 CJ @ 16"O.0 2x12 R @ 16"O.C. ( I I I doubled,or alternate connectors,such as shear plates,shall be used to maintain load path. 13-All joist and beans hangers and fasteners used on the exterior are to be t —L j (2)When wall sheathing is continuous over connected members,the tabulated number of nails shall be permitted to be Simpson Type 304 or 316 Stainless Steel. 9-0"TRAY I j® I VI x I ! reduced to 1 - 16d nail perfoot. - - - - - � "I CEILING i I SIMPSON HW -- I ! 14-All bolts nuts and washers are to be stainless steel or hot dipped galvanized. - - ; (2)2x12 RAFTER COL. j I SIMPSON JOIST rZ I HANGER ' " HANGER IUT412 I GIRDER TO i Steel (2)1-3/4 X 912"L�jL HEADER ,% I I j I 1 r --{2}?X6? I GIRDER I E 1 COL I I I 3.5"X35"X1/4" I I (3)2X6 COL. ! 1 1 All steel!s to be ASTM Specification A 36 i --------------- S e .. 3.5"X 3.5"X 1/4" ABO -- ! STEEL COL. I I (3)2�6 COL. i STEEL L -- --------- - ------- . _.-_ -_.- - AB C 2 2x12 RAFTER---------------- ----' _ -_ - - - - - - - - - ----- -------- ------ L CO - ! ' ABOVE W12 X 40 GIRDER FLUSH � IJ :-_-- �_ ___.__-._-.---_.___-- -----.,I__--�__-- --------- -----_--+---.--T- -- - ' _---- -1 Ti i 2-All bolted connections are to be made with A-325 bolts. -= _ �- --- -- ---I-- u 3 2X4 COL. I' (4)2X4 COL. I (4)2X4 COL. i i IMPSON GIRDER TO ! \ ! r -- --IL J ,_,_._ ABOVEBARING WALL I !! 3-Square/rectangular/circular columns are to be ASTM Specification A500. I l (3)2X6 COL. 1 {----�--- - --- _.._� _ IRQER.HHUS410_----- --- --� ( TO RIDGE - (2)2X6 COL. o (3)2X4 COL.ABOVE r _ w�-- — ----- ._—__----- ! i l o l Iti j' I i 2 i I 6; j ----- ! FRAMING w 1 V I 2x8 CJ @ 16"O.Ci; i I 1 `(�' ! (2}2X6 COL ABOVE �'�-' j i t j --� J 1 i = l i I• • mD J 1 --� Ill 3" No.8 SCREWS 12"OC -J', ti 2x12 RR @ 16"O.C. 2x12 RR at7 16"0 C. _ I I `-�1 2x12 RR 16"O.0 i.__ .�_... _.1 i ------------ -u- I =i ,..-_ SIMPSON JOIST j I i LIGHT WOOD-FRAME WALL ---- ----- J _. _... T I d-0-N — x _. xSIMPS GIRD RT_0_ I- ' ` = 2 2X6 COL. 1 HANGER IUT3512 GIRDERHHUS4 0 I I -------- I -- -- (7-- ----- I ' - -- -- q "' --_--' ---- ----- WASHER E ,-�;}_--1,' R TYP.) — ----------\ r --_ --, ------- (I i�i i 2'I �3)2X6 COL ABOVE I r-- .....-- --- - -- 3_5��X 5.5" a�{, _ I + i I I (3)2X6 COL. ' I %"PLYWOOD l ! LVL COL. ! I (31X4 COL\,, ( RAFTER I F =i i 0:,1 3/4.°'X 11-7/8"LVL FLUSH GIRDER - L_ _ �i (2)2x12RA _ =�- - - - - - -s.--- - - - --_ - - - I -(3)2X6 COL. TO RIDGE �I _ _ - - -----� Lill iIOGIRDER(3)2X4 COL. • - (3)2X6 COL. 2 2x��COL /g"LVL SrIRDER\ I- - SIMPSON GIRDER TO 2 1-3/4'1 3/41 X�1 7l8"LVL GIRDER � (3)2X6 COL III GLASS- - (2)1_3/4_X 11 7 -, �_ -� - - - - ( - - - - ABOVE ! IOI GIRmERHHUS410 _ -_ - --- LINE OF 8'-0" a;, ('1)1�141 Xf 912"(LVL HEAD F'r ��'_--- i !i- i --_- r1 ( ) . f 4 2X4 COL.ABOVE - I CEILING - t4)2�4 COL.ABOVE I �, / w I \ I - I!d' o a 11 1 1 1 I 1.2/RR 6"O.C. % i / I 'I' / x i f i ;SIMPSON JOIST I! PLASTIC-COATED PERMANENT WOOD 1 1 ,• I ! ? j ` �2)1-3/4"X 1 �!8"LVL, -iHANGER IUT3512 'V. 2x8 CJ 16"0 C. I ! { li I ! / 1" - I; i SCREW ANCHORS FLUSH;GIRDER' �� ?2X6 COL. 7 \ v GLASS I. w -I r 1 - —,— ----- i _ 2)2X6 COL. �Iu (2)2x121RAFTER 1 I; I (2) 6L6L= - � `' - -i _-- ! -_---- - - - - - - -� \'�-- " 1 - \ ¢ -I _. -. _ _.- BOX OUT FOR I ,_ r - -- i i S 3 ` I I ! ( I I I ! (---- ------- ;-r- - - -- --- -- ----1 i , Y PLYWOOD --- j' SKYLIGHT(30'k22") cZS� c co w +.__ �-�..- 1 I ` — --- i ' �'--- -----_ I I o 1 I rt `� ! I R FRAMING SEE SIMP'SON LSTA36 17 - - - - - - - - F - - - - / \ I I ! r—_. -_) --' I I I C� r-- L - -i --- -_-- DETAIL STRAP .I .J (2)2x12RA TER �, �, !'----� C ! 3 2X6 COL.% I ---- I v ! I (2)2X6 COL. T------------------� ! , i �� I, O !1 8'-0"PLATE (3)2X6 COL. 'i _ h ; I { ( (3)2X6 COL.ABOVE � HEIGHT J- I ` I ' I 11718"iTJI 230 FJ@ J (�) X4OOL. I III I �•.__ - WASHER(TYP.) i._.--_.-._.-------.__.__-_ ' I 3 2X6 COL. - 2 - - - " - -H - - - - -• 2 1 3/4"X11-7l8"LVLFLUS- ER - - - - 1 - (2)2xr12 RAFTER U2)1 3/4 X 912"1 LVL HEADEq ! ,-(3)2XECOL. - r--- --- - - - I PLYWOOD OPENINGS PROTECTION; picail Window and Door Header --� 13 2X6 COL. t O O 1 3/4 X 11 7/8 LVL FLUSH GIRDER f O D ! � (2)2X6 COL. i i (3)2X4(OL. ' O' ' ! i '; THICKNESS DEPENDS ON WINDOW �-(2)2X6 COL.ABOVE ! I ;TC�RIDGE �! OPENING WIDTH(I) Stra in Detail Each Corner j 2x8 CJ 16"O.0 �Y+,� ` i w (3)2X4 COL.ABOVE w 6'-0"KNEE WALL I i 1 ! 3"No.8 SCREWS 12"OC I I ; I ! DETAIL A-TYPICAL ATTACHMENT OF NITS ! 9'-0"TRAY I i x I _ 'r PLYWOOD OPENINGS PROTECTION TO `CEILING '1 11 7/8"TJI 230 FJ @ 16"O.C. j j � I �� WOOD-FRAME BUILDING V' 0 I :D 2x12 RR 16"!0. . I id, i 1 CS 2x12RR 16"oC.i z i'', I �— / ` I ! x ; BEAMINGWALL / I z j Alternate to 120 MPH Certified i / I NOTE: IN LIEU OF SCREWS LUGS WITH NUTS AND WASHERS MAY BE ' Window Installation USED ,,��^ I '�� ! SIMPSON GIRDER ;�;; i (2)2X6 COL. TO GIRDER C3)2X6 COL. _ (2)2X6COL I i (3)2XrCOL. ABOVE HHUS410 Plywood Panel Window and Door �� j ! N I I (3)2X6 COL. ABOVE I - Yy I N v (2)2X6 COL.TO ! I ! _ �// _ *b I i i (2)1-314"X 11-718"LVL FLUSH GIRDER J•CO / (2)1-3l4 X11-7/8"LVLFLUSHi IRDER j Protection for Wood Framed Buildings A,' .X y /� ----- ---- - ---FRI - - - - - - - - - -_- - - _ _ - - - - - - - co --------------- / (3)2X6 COL I (3)2X6 COL. i (3)2X6 COL. SIMPSON JOIST 1 (3)2X6 COL. (2)2X10 HEADER Ij i i I I (2)2X-0L i 1 I -Z _ _J / 1 i ABOVE -- EibPSON IC)IST- - -_ ABOVE_ I HANGER IUT3512 ti SIMPSON GIRDER- -hRidtU'ERtU526- - - w Q- -._--. T x o 0 / I I SIMPSON JOIST _ ZD ( I j I �Q \ Zo I! HANGER IUT3512 t i HHHUSI410ER I x J I P� (2)2x6 COL. M i I N J ! aFESStO P B j 1 I i (3)2X6 COL I� @� - _ .� _ ,-- +- - - - -- -- .1 cv cv r, co ---- 2)2�6 COL %"'�� / �5 i !I ABOVE I - _ (�i I` (2),?XH1HEA[ R _.-_ --- - - - -- -- - - - ._ - --- - - - - - - -- - -- -- - - - - - - --- -- - -- - - - - {2)2X10H ADER ` - - - -- - - - - - - - - - -- -- - - - \ r (2)2X10 HEADER ' Condon Engineering, p,C, BRANDVOLD RESIDENCE (2)2x6 COL. (2)2x6 Ca., ' I Scale: 1/4"=1'-0" - - �.. - --- - - _ _ _ - - - -_ ___ _.- -"._ -_ - -- - - - -� 1955 BAYSHORE ROAD 4 ROOF FRAMING PLAN - _ - I Plans are prepared by Condon Engineering,P C. It is a violation of the New York State Education Drawn by:JJC 1755 Sigsbee Road G REE N PO RT, NY O F __ __ __ -. .- __ __ _._ J Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Mattituek,New York 11952 SECOND FLOOR FRAMING PLAN Professional Engineer,Architect, , Land Surveyor,to alter any item in any way.!fan item bearing (631)298-1986 2 n d F I oo r & E the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Land Surveyor shall affix to the item his/her seal and the notation"Altered by"followed by his/her Date:6-15 2006 /� S-3 signature and the date of such alterations,and a specific description of the alteration. Roof Framing Plan 3 0 O (2)518 Inch - galvanized bolts, M nuts,anod washers ___ _ _ (2)5/8 Inch ""—" ---- '� -- - - (4)3/4Inch CC;> galvanized bolts, gal ed bolwashets, (2)2X10 ACQ GIRDER 0 Ot 0 nuts,and washers --- ---- -- --- nuts,and ilD 0 — 0 �D 0 O O O Proposed Sal high min.railing Proposed ral high min.railing 2 (See Architectural plans for details) (2)2X10 ACQ GIRDER (See Architectural plans for details) I (2)2X10 ACQ GIRDER Simpson H-2.5A 2x4 Studs @ 16"o c. O0 hurricane ties floor SP.PSONLSTAX O 0 2X10 ACQ ledger with joists to girder STPAP 3 I I 514x6ACQ 5/4x6ACQ � 5/8"lag bolts @ 16"O.C. slmPsoNLTPs wood decking Simpson H-2.5A wood decking s hurricane ties floor STRAP Simpson H-2.5A hurricane _Typical Wall and joists to girder 2X8 ACQ FJ 16"O.C. joists g Sill Strapping 2X8 ACQ FJ @ 16"O.C. g 2X8 ACQ FJ @ 16 O.C. @ ties floor to girder Simpson LUS26 -- --(2)2X10 ACQ Girder �� Simpson ILUS26 r_-- (2)2X10 ACQ Girder (2)2X10 ACQ Girder Detail t (O 10 ACQ ledger with 5/8"lag joist hangers Imi joist hangers 0 I Jolts @ 16"O.C.staggered •' 4X4 ACQ col urn (Typ.) O I I ` I 4X4 ACQ column(Typ.) 4X4 ACQ column(Typ.) 3 Grade �, Grade o o Grade ° I O 10 :: a. 0 o I o f L — - - ' • e Simpson CB44 with 5/8"galy. Simpson CB44 5/8"galy. Simpson CB44 with 5/8"galy. 01 0 bolts(Kwik bolt KBII 316SS bolts(Kwik bolt KBII 316SS bolts(Kwik bolt KBII 316SS \L 5/8 2-3/4) 5/8-2-3/4) 5/8-2-3/4) —I_ Bi foots stems footin form BF24 Bigfooi systems footing form BF24 � I Cl) '�.,• � 12"O Sonotube `n 9 Y 9 0 0 0 footing to grade(iyp.) with 10"0 sonotube filled with concrete. with 10"0 sonotube filled with . . '• concrete. . a I I � 0 o I C> 0 I o, A Deck Section B Deck Section Deck Section at Screened Porch — I Scale 1/2 inch = 1 ft. Scale 112 inch = 1 ft. Scale 1/2 inch = 1 ft. � I 0 � � I X(D - (Do 0 o) O �� 0 RIFICN TOP PULE TOP PATE Simpson LSTA30 Ridge Q Strap at each Rafter O 0 OR OR CONT.RIDGE VENT "° Simpson MTS30 Rafter Strap Nailing Zones for Roof Sheathing in 120 Simpson MTS30 Rafter Strap TYP.ROOF CONSTRUCTION: � •Tov PUTT at each Rafter Tail MPH Peak Gust Wind Zone " at each Rafter Tail ASPHALT SHINGLE ROOFING ON 15#FELT ON (2)1-3/4"X 14"LVL STRUCT.RIDGE �PUE 5/8'PLYWD.SHEATHING ON 2x12RR@ 16"O.C. ' M.— T— Zone 1 Zone 2 Zone 3 Ix p,N2 CONN&TOR" PE"PIF1B1 A Field 6"O.C. 12"O.C. 4"O..C. 2X8 RR @ 16"O.C. T 2X8 RR @ 16"O.C. Two Simpson H2.5 Hurricane Ties Panel Edges 6"O.C. 6'O.C. 4"O..C. TOPPPTE two Simpson H2.5 Hurricane Ties at each Rafter Tail at each Rafter Tail 2x8 CJ @ 16"O.C. Nailing Requirements for 120 MPH,3 Sec. Peak Gust, "Thick Roof Sheathingwith 8d Common Nails \ R,"=°PM` 8'-0"PL HT. 2X8 CJ 16"O C. @ 2X8 C J @ 16"O.C. Roof Sheathing Nailing Details 2X12 RR @ 16"O.C. BOTTOM SCALE: 1/8"=1'-0° Two Simpson H2.5A Hurricane Ties 12 12 PATE MD each Rafter Tail 10 10 2X12 RR @ 16"O.C. 6-0"KNEE WALL RIMJ VST TOP PLATE V-0"KNEE WALL BOTTOM s71D Simpson ST22 Strap PLATE SECOND FL. at every other stud ,J, 11 7!8"TJI 230 FJ @ 16•O.C. Typical 2nd Floor I RIMJg51 — ly— 2'-6" _Strapping Detail TOP 2X10 RIDGE Simpson LSTA30 Ridge . NTS PLATE Strap at each Rafter , TYP.EXTERIOR WALL CONSTRUCTION:CEDAR 2X8 RR @ 16"O.C. 41 -QLL Simpson ST22 Strap SHINGLES ON 15#'BLDG.PAPER ! at every other stud o ON 5/8 PLYWD.SHEATHING ON Typical 2nd Floor 2x6 WD.STUDS @ 16"O.C.5/8 DRYWALL 2x6 COLLAR TIES Strapping Detail NTS FIRST FLOOR sINPs°NLSTA6 \ , s (2)2X1 9 i"TJI 230 FJ @ 16-O.C.0 RR @ 16"O.C. S>pAP DECORATIVE WOOD BRACKET I I I SINPSON LTP5 (SEE ARCH ITECTURAL PLANS DFlR DETAILS) STPAP I ': 1/2"EXPANSION SEAL I �•: B TCP PP,E I ..•:� @ PERIMETER i •� S-1 Typical Wall and EXIST.GRADE ; rill, i CRAWL SPACE : I Sill Strapping Detail( ) . I _ • . OR SIMPSON HD2AWITH SSTB20AT A I I EACH COLUMN AND EVERY ? I I I Simpson StrongTieAC6 ' •' Simpson MTS30 Rafter Strap OTHER WALL STUD. " � S-1 2"RAT SLAB I " at each Rafter Tail I :;•'; i .. ' I Simpson AC6 Post Cap ° Girder to Each Column Rlnz car•ECTau O r .• • SINPSON LSTA'6 Typical Building Sectionco Two Simpson H2.5 Hurricane Ties !, 5 aAa A at each Rafter Tail $INP9°NLTPS 'r ` • • saAP Scale 1/4 inch = 1 ft. { �� Typical Wall and y 11-7/8"TJI FJ /—Simpson ST6224 Strap Column to Girder(2 per Column) Sill Strapping @ 16-o.c. �� ,• Detail 2X8 FJ @ 16"OT.0 Simpson Strong-Tie (( HD2A with SSTB20 .<, (3)1-3/4"X11-7/8"LVL GIRDER W/(2)1/2"FP BELOW JOISTS BRANDVOLD RESIDENCE Scale:As Shown Condon Engineering, P.C. 1955 BAYSHORE ROAD %"D Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education Drawn by:JJC 1755 Sigsbee Road G REEN PO RT, NY O Law,Article 145,Section 7209,for an person unless actin under the direction of a licensed D Section at Terrace E ecti o n at 4'-0" Roof Overhang Professional Engineer,Architect,or Lan Surveyor,to alter any item in any way.if an item bearing Mattituek,New York 11952 the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or (631)298-1986 Scale 112 inch = 1 ft. Scale 1/4 Inch = 1 ft. Land Surveyor shall affix to the item his/her seal and the notation'Altered by"followed by his/her Date:6-15-2006 Sections & Details signature and the date of such alterations,and a specific description of the alteration. 3