Loading...
HomeMy WebLinkAbout33045-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town Hall Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33431 Date: 12/10/08 THIS CERTIFIES that the building COMMUNITY CTR BUILDING Location of Property: FOX LA FISHERS ISLAND (HOUSE NO. ) (STREET) (HAMLET) County Tax Map No. 473889 Section 12 Block 1 Lot 5.1 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this office dated APRIL 18, 2007 pursuant to which Building Permit No. 33045-Z dated MAY 18, 2007 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is ALTERATIONS TO AN EXISTING COMMERCIAL BUILDING AS APPLIED FOR, PER PLANNING & ZBA APPROVALS. The certificate is issued to B KINLIN FOR FIDCO (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL C10-06-0014 12/10/08 ELECTRICAL CERTIFICATE NO. 3037064 08/07/08 PLUMBERS CERTIFICATION DATED 07/31/08 GELLO PLUMBING uth ized SZgnature Rev. 1/81 Form No.6 f ? �r rM TOWN OF SOUTHOLD BUILDING DEPARTMENT 08 TOWN HALL AUG 20 I, l 765-1802 - APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal (S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead, 5. Conunercial building, industrial building, multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforniing uses, or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines, streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied; the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling$25.00, Alterations to dwelling$25.00, Swimming pool $25.00, Accessory building$25.00,'Additions to accessory building$25.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy- Residential $15.00, Conunercial $15.00 Date. New Construction: _ Old or Pre-existing Building: (check one) Location of Property: ��6 ��j412_< iALA-v House No. Street Hamlet Owner or Owners of Property:�����5 ��11 b" .6-L' 'F . l Suffolk County Tax Map No 1000, Section Block _ Lot Subdivision A- Filed Map. . NJ A_ _ Lot: VA- Permit No. -j 3o 4 Date of Permit. 51 IS �)4- Applicant: wW ply �,..� Health Dept. Approval: � � D/•���Underwriters Approval: Planning Board Approval: 102 Request for: Temporary Certificate_ Final Certificate: (check one) Fee Submitted: Applicant Signature f� � FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33045 Z Date MAY 18, 2007 Permission is hereby granted to : B KINLIN FOR FIDCO 330 W 38 #1006 t FISHERS ISLAND,NY 06390 for ALTERATIONS TO AN EXISTING COMMERCIAL BUILDING AS APPLIED FOR, PER PLANNING & ZBA BOARD APPROVALS at premises located at FOX LA FISHERS ISLAND County Tax Map No. 473889 Section 012 Block 0001 Lot No. 005 . 001 pursuant to application dated APRIL 18 , 2007 and approved by the Building Inspector to expire on NOVEMBER 18, 2008 . Fee $ 5, 338 . 80 G Authorized Signature ORIGINAL Rev. 5/8/02 • TEL. 765-1802 ' �pc�v� 0 BOG TOWN OF SOUTHOLD OFFICE OF BUILDING INSPECTOR cP rn P.O. BOX•728 TOWN HALL SOUTHOLD,NX? 11971 C E R T I F I C. A'-T. I O :N Date D Building Permit No, Owner D_16 0 (please print) vy- �lPlumber � C/t (please print) I ,certify that the solder used in the water supply system contains less than 2/10 of 1% ,lead. S IATL557 d IJ �'r�J Yat2 k, tS (plumber's signature) Sworn to before me this 31 st day of JV , - 'I Notary .Public Notary -Public, Su. K County • � .�Ct�.J�.QJLCAllo' - . MAR B PANKIEWICZ Notary Public State of New York 0 67950 Commission EX Tres Y/3%w 0 dwol, ��s Suifo/k C'ot�nf r�rJ�rJ�rJ 2[PrfrfrJ'rJ�rJ�rJ�rJ��PrJ��PrJ'2rPc I�r�t1�rJtJ�tJ'tP�lr('2rl�.fcPr�r�r!'r__I't�rJ�r�cnr�rJ�rJ�rJ� !r.!cPrJ�r�rJ�rnr l'arJ'r l'2r__I'�r.J�rJ�rJ�r�r�r� I� 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 S NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 S 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET - NEW YORK, NY 10038 55 5 CERTIFIES THAT S 5 5 5 Upon the application of upon premises owned by 5 5 5 SZ&S CONTR. INC. COMMUNITY CENTER FISHER ISLAND PO BOX 202 FOX LANE 5 FISHERS ISLAND, NY 06390-0202, FISHERS ISLAND, NY 06390 5 Located at FOX LANE FISHERS ISLAND, NY 06390 C 5 Application Certificate Number: 5 5 PP Number: 3037064 3037064 5 5 5 Section: Block: Lot: Building Permit: 0 BDC: ns11 S 33Otf5- 5 5 Described as a Commercial occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: C5, 5 First Floor,Second Floor,Outside, Lj 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the 7th Day of August, 2008. 5 5 Name QTY Rate Rating Circuits Tyne 5 5 Alarm and emergency equipment 5 5 Emergency Light 32 0 0 5 5 Exit Light 14 0 0 5 SAppliances and Accessories 5 5 Air Conditioner 2 0 0-15000 Amps 5 5 Air Conditioner 6 0 Above 1500 BTU S 5 Dish Washer 1 0 40 Amps 5 Elevator 1 0 3 H.P 5 Exhaust Fan 6 0 FAR 5 5 Furnace 2 0 Gas 5 Time Clock Switch 1 0 r, 5 Panels 5 5 1 100 12 5 1 100 16 5 5 1 60 18 5 5 1 100 20 5 5 5 1 125 25 55 1 100 30 SEc7I 5 Continued on Next Page 1 of 3 5 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 o V 21MIM009191 -- cPcJ�rJ�rJ�r..('cPtJ�rJ�rJ�r��.lrJ�r Pr_.(roc.tc.nrJ Kr lrJEJlficPrJE �� PtPrJ�rJ�r l'r_I'rJ�rJ�r ll?fr-_I't_!'r.PrJ�t1c.I�c J�r��PrJ�c 1�t_rL LrLc LrL C0 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 CS 5 40 FULTBON ST`REETTF NEWYORK ELECTRICITY NY 10038 5 5 CS 5 CERTIFIES THAT 5 S 5 5 Upon the application of upon premises owned by 5 �5 5 5 Z&S CONTR. INC. COMMUNITY CENTER FISHER ISLAND PO BOX 202 FOX LANE 5 5 FISHERS ISLAND, NY 06390-0202, FISHERS ISLAND, NY 06390 S 5 Located at FOX LANE FISHERS ISLAND, NY 06390 5 5 Application Number: Certificate Number: S pp 3037064 3037064 cS 5 Section: Block: Lot: Building Permit: 0 BDC: ns11 5 5 5 5 Described as a Commercial occupancy, wherein the premises electrical system consisting of Cj 5 electrical devices and wiring, described below, located in/on the premises at: S C5� First Floor,Second Floor,Outside, 5 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 authority having jurisdiction, and found to be in compliance therewith on the nth Day of August, Zoos. 5 Name QTY Rate Rating Circuits Tyne 5 Service 5 Service Disconnect: 1 600 cb 5 5 Service IPnase3W Service 5 Rating600Amperes 5 5 Wiring And Devices 5 Disconnect 2 0 1-30 amp 5 Disconnect 8 0 1-30 amp 5 5 Fixture 91 0 Incandescent 5 Fixture 98 0 Fluorescent 5 Lighting Track 100 0 ft 5 5 Paddle Fan 11 0 5 5 Receptacle 1 0 fryer Special/twist lock 5 Receptacle 4 0 bowling Special/twist lock 5 5 machines 5 SReceptacle 24 0 GFCI 5 Receptacle 138 0 Gen,Purpose 5 Switch 60 0 Gen,Purpose 5 5 5 seal 5 Continued on Next Page 2 of 3 5 5 5 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 _ 5 RI ���EMPRI �MEEERp��MP�RIEL �� o a Ln��n�.n���.n�n���>:n�nrs��n����� n�.n���l-��.r�n��n������nr��n�n�n�n��n��.n�������nELPLL3ffln o 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET — NEW YORK, NY 10038 5 5 5 CERTIFIES THAT 5 5 5 5 Upon the application of upon premises owned by 5 5 5 5 Z&S CONTR. INC. COMMUNITY CENTER FISHER ISLAND 5 PO BOX 202 FOX LANE 5 5 FISHERS ISLAND, NY 06390-0202, FISHERS ISLAND, NY 06390 5 50 5 5 Located at FOX LANE FISHERS ISLAND, NY 06390 � 5 A Certificate Number: c5 Application Number: 3037064 3037064 c5 5 Section: Block: Lot: Building Permit: 0 BDC: nsl1 5 5 5 Commercial 5 Described as a occupancy, wherein the premises electrical system consisting of 5 5 electrical devices and wiring, described below, located in/on the premises at: 5 First Floor,Second Floor,Outside, 5 5 c5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the 7th Day of August, Zoos. 5 5 Name QTY Rate Ratine Circuits Twe 5 5 5 5 5 5 5 5 5 5 5 S 5 5 5 5 5 5 5 5 5 5 5 5 5 seal 5 3 of 3 5 5 5 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 o ������������������1��OOP�LPL�E100 I J ��������9IVE PM ����� o MAILING ADDRESS: PLANNING BOARD MEMBERS �F SU(/T P.O. Box 1179 JERILYN B.WOODHOUSE O�� y0l Southold, NY 11971 Chair Q OFFICE LOCATION: KENNETH L.EDWARDS Town Hall Annex MARTIN H.SIDOR G 54375 State Route 25 GEORGE D.SOLOMON �� �� (cor.Main Rd. &Youngs Ave.) JOSEPH L.TOWNSEND lij'MU Southold, NY 'Y 11 Telephone: 631 765-1938 Fax: 631 765-3136 PLANNING BOARD OFFICE September 17,2008 TOWN OF SOUTHOLD Kinlin,Rutherford Architects ATT. Bruce Kinlin 19 Union Square west,6th floor New York,NY 10003 �?(, 0;r 17 RE: Fishers Island Community Center SCTM# 1000-12-1-5.1. SEP 17 2008 1 Dear Mr.)Kinlin: = The Planning Board has reviewed your request for site plan amendments and a final inspection,and has found that there are several site improvements that must be completed prior to receiving a Certificate of Occupancy. These improvements include: • Installing the fence along the edge of the basketball court adjacent to the parking area. • Installing the gravel for the parking area as described on the approved stamped site plan. • Installing the wood guardrail as described on the plan. Your request to replace the bollards around the pole with split-rail fence was denied bythe Planning Board due to the fact the proposed fence would not be a safe alternative solution. The Planning Board did approve the request to remove the walkway between the parking area and the courts,however,a gap in the guard rail should be left where the gate to the basketball court will be located to facilitate entrance to the court. At the time the above has been completed,please contact this office so that we may review your request for final inspection. Any future requested change to the site plan should include a copy of the relevant section the approved stamped site plan noting the location of the requested change. If you have any questions regarding the above,contact me anytime. Thank you. Since y, Kristy er Senior Planner cc: Planning Board Mike Verity,Chief Building Inspector Fishers Island Community Center,Inc 04 MAILING ADI AI SS: PLANNING BOARD MEMBERS *�f SO Ujt P.O. Box 1179 JERILYN B.WOODHOUSE �OV� �1QlO Southold, NY 11971 Chair OFFICE LOCATION: KENNETH L.EDWARDS N Town Hall Annex MARTIN H.SIDOR G O 54375 State Route 25 GEORGE D.SOLOMON 'Ql (cor. Main Rd. &Youngs Ave.) JOSEPH L.TOWNSEND �UN% Southold, NY Telephone: 631 765-1938 Fax: 631 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD f April 10, 2007 Lily Rutherfurd j ijPR ! 7 7 Kinlin Rutherfurd Architects, PLLC - 330 West 38th Street, Suite 1006 New York, NY 10018 RE: Proposed Site Plan for Fishers Island Community Center, Inc. Located on the a/s/o Fox Lane approximately 386' n/o Whistler Avenue known as 98 Fox Lane on Fishers Island SCTM# 1000-12-1-5.1 Zoning District: General Business (B) Dear Mrs. Rutherfurd: The Southold Town Planning Board, at a meeting held on Monday, April 9, 2007, adopted the following resolutions: The final public hearing was closed. WHEREAS, this site plan is for the proposed renovation of an existing 15,984 sq. ft. building where 8,048 sq. ft. is commercial recreation, 797 sq. ft. is storage, 2,765 sq. ft. is meeting hall (non-profit) and 4,374 sq. ft. is miscellaneous where 56 parking spaces are required with 28 spaces provided onsite and use of nearby Ferry District parking is proposed on a 1.28-acre parcel located in the General Business District on the a/s/o Fox Lane approximately 386' n/o Whistler Avenue, known as 98 Fox Lane on Fishers Island. SCTM #1000-12-1-5.1; and WHEREAS, Fishers Island Development Corporation (FIDCO) is the owner of the property located on the a/s/o Fox Lane approximately 386' n/o Whistler Avenue, known as 98 Fox Lane on Fishers Island; and WHEREAS, on September 5, 2006, the agent, Kinlin Rutherfurd Architects, working for the applicant, Fishers Island Community Center, submitted a formal site plan for approval; and WHEREAS, on May 16, 2006, the Fishers Island Ferry District, responded by letter granting permission to park "as many as 40 cars parked on our property" and the Planning Board accepts this letter with a request that the Fisher Island Ferry District submit a formal resolution; and Fishers Island Community Center Page Two April 10, 2007 WHEREAS, on October 5, 2006, the Architectural Review Committee reviewed the architectural drawings and associated site plan materials and withheld making comments until the Fishers Island ARC liaison responds with comments; and WHEREAS, on November 2, 2006, the Architectural Review Committee reviewed the letter from Reynolds DuPont, Jr., the Fishers Island ARC liaison, dated October 31, 2006 and approved the project as proposed and the Planning Board accepts this recommendation; and WHEREAS, on November 16, 2006, the Suffolk County Department of Planning responded after review and determined this matter is for "local determination as there appears to be no significant county-wide or inter-community impact(s)" and the Planning Board accepts this pursuant to 239L & M General Municipal Law; and WHEREAS, on November 27, 2006, the Suffolk County Department of Health Services responded after review that an application has been received under reference number C10-06-0014 and the application is incomplete pending the submission of the following items: • Completed Short Environmental Assessment Form • Public Sewer Availability Letter; and WHEREAS, on January 8, 2007, the Southold Town Planning Board, acting under the State Environmental Quality Review Act (6 NYCRR), Part 617.5 c, made a determination that the proposed action is a Type II and not subject to review; and WHEREAS, on January 25, 2007, the Southold Town Zoning Board of Appeals granted a "Special Exception under Code Section 280-48B (6, 8)" as applied for and described under Appeal #5990 to "convert the existing industrial building into a new non-profit recreational facility and (nonprofit) meeting hall with storage and office areas"; and WHEREAS, on February 1, 2007, the Southold Town Engineer reviewed the site plan materials and replied with comments and these comments have been incorporated into the revised plan to the satisfaction of the Planning Board and the Town Engineer; and WHEREAS, on March 13, 2007, the Fishers Island Union Free School District submitted a motion approved by the Fishers Island School Board of Education that states "Approve the request by the Community Center to allow for the installation and maintenance of a bike rack on school property next to the tennis courts. It is understood that the installation and maintenance of the sidewalk bordering the tennis court is the responsibility of the town and Community Center" and the Planning Board accepts this motion with a change that the installation and maintenance of any improvements as shown on the proposed site plan, including any sidewalks, is not the responsibility of the Town of Southold; and WHEREAS, on March 16, 2007, the Southold Town Building Inspector reviewed and responded "The proposed use Community Center is a permitted use by special exception in this B district and is so certified" with a reference to the ZBA appeal #5990; and Fishers Island Community Center Page Three April 10, 2007 WHEREAS, on March 21, 2007, the Fishers Island Ferry District, passed a resolution which states "Resolved that the Board of Commissioners hereby grants permission to the Fishers Island Community Center that they may utilize any available parking spaces located in our overnight parking area, situated at the end of Fox Lane on Fishers Island" and the Planning Board accepts this resolution in conjunction with Fishers Island Ferry District letter dated May 16, 2006; and WHEREAS, on March 22, 2007, the Fishers Island Fire District responded that there is adequate fire access and the Planning Board accepts this recommendation; and WHEREAS, on April 3, 2007, the agent submitted a letter regarding the excess material inside and outside of the building and states, "This material has been left behind by prior occupants of the building and will be removed as part of the demolition phase of the project" and the Planning Board accepts this letter for the file; and WHEREAS, that the Southold Town Planning Board, pursuant to Town Code §280-131 B (5), waives the parking requirements for the proposed site plan as the applicant has secured permission from Fishers Island Ferry District for the use of their property for additional parking; and WHEREAS, the Southold Town Planning Board, pursuant to Chapter 55, Notice of Public Hearing, has received affidavits that the applicant has complied with the notification provisions; and WHEREAS, the following items shall be required: 1. All outdoor lighting shall be shielded so that the light source is not visible from adjacent properties and roadways. Lighting fixtures shall focus and direct the light in such a manner as to contain the light and glare within property boundaries. The lighting must meet town code requirements. 2. All signs shall meet Southold Town Zoning Codes and shall be subject to approval of the Southold Town Building Inspector. 3. As per the landscape survivability guarantee, the applicant agrees to replace any of the landscaping which dies within three (3) years of planting; be it therefore RESOLVED, that the Southold Town Planning Board, pursuant to Town Code §280-131 B (5), waives the parking requirements for the proposed site plan provided that Fishers Island Ferry District continues to allow parking on their property as permitted in their letter dated May 16, 2006 and resolution dated March 21, 2007 and it will not have a detrimental effect on the public health, safety or general welfare; and be if further RESOLVED, that the Southold Town Planning Board, pursuant to Town Code §280-131 B (5)(b), reserves the right to review the parking requirements again if a change of use is proposed; and be it further Fishers Island Community Center Page Four April 10, 2007 RESOLVED, that the Southold Town Planning Board has reviewed the proposed action under the policies of the Town of Southold Local Waterfront Revitalization Program and has determined that the action is exempt as outlined in the April 5, 2007 memo prepared by the LWRP Coordinator; and be it further RESOLVED, that pursuant to Southold Town Code 280-131 Part I, the applicant agrees to incorporate all the requirements, comments, and recommendations of each reviewing agency as referenced above and as indicated on the site plan and corresponding attachments; and be it further RESOLVED, that the Southold Town Planning Board grant approval on the site plan sheets (1 of 2 and 2 of 2) prepared and certified by Richard H. Strouse dated June 23, 2006 and last revised March 30, 2007, sheets A101, 102 and A201 prepared and certified by Bruce Kinlin of Kinlin Rutherfurd Architects dated November 16, 2005 and last revised February 13, 2007 and the attached lighting catalog cut and authorize the Chairperson to endorse the site plans with the following conditions: 1. The owner, agent and/or applicant shall receive approval from the Suffolk County Department of Health Services for the approved construction and submit such approval to the Southold Town Planning Department for review. If such approval varies from this approved site plan, the Planning Board reserves the right to the review of a new and site plan application. A copy of the Suffolk County Department of Health Services approved plan must be submitted to the Southold Town Planning Department within thirty (30) days of receipt. If applicant/agent/owner fails to adhere to this requirement this approval shall become null and void. 2. The owner, agent and/or applicant agrees the responsibility for the installation and maintenance of all improvements as shown on the approved site plan, including sidewalks, is the responsibility of the Fishers Island Development Corporation. No encroachments onto property owned by the Fishers Island School District shall be authorized by the Planning Board without written consent of the Fishers Island School District and final approval of the Planning Board. 3. The owner, agent and/or applicant shall remove all excess material, including any hazardous material, inside and outside of the building and dispose of such material in an approved upland facility. If necessary, the applicant must obtain any necessary permits prior to disposal for any hazardous materials. 4. The site plan approval requires that all work proposed on the site plan shall be completed within three (3) years from the date of this resolution. 5. Prior to the request for the Certificate of Occupancy, the owner or authorized agent must request, in writing, the said Building Inspector and the Planning Board to perform an on-site inspection to find the site improvements are in conformity with the approved amended site plan. Fishers Island Community Center Page Five April 10, 2007 6. Prior to the request for an on-site inspection, the applicant/agent/owner must submit a copy of all required approvals from any necessary agencies to the Southold Town Planning Department. 7. If the as-built site improvements vary from the approved site plan, the Planning Board reserves the right to request a certified as-built site plan detailing all the changes. 8. Any changes from the approved site plan shall require Planning Board approval, and any such changes without Planning Board approval will be subject to referral to the Town Attorney's Office for possible legal action. 9. The Planning Board will issue a final site plan approval in the form of a letter following a site inspection and at the time the site improvements are found to be in conformance with the approved site plan. A copy of the approved site plan is enclosed for your records. As per the Town Code, one copy each will be distributed to the Zoning Board of Appeals, Building Department and Town Engineer/Highway Department. If you have any questions regarding the above, please contact this office. Very truly yours, Jerilyn B. Woodhouse Chairperson Enc. Cc: Southold Town Zoning Board of Appeals Southold Town Building Department Southold Town Engineer James McMahon, Community Development Director Fishers Island School District (Resolution only) File O��OF SOUlyol 00UNT{>� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 0 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION ° [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY ] FIRE SAFETY INSPECTION 41 [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: A jZ� In )Sp _ Hass L� ��- DATE ANSPECTOR a MAILING ADDRESS: PLANNING BOARD MEMBERS P.O. Box 1179 JERILYN B.WOODHOUSE o��OF S�UryOl Southold, NY 11971 Heatherchanza ~ OFFICE LOCATION: KENNETH L.EDWARDS Town Hall Annex MARTIN H. SIDOR G Q 54375 State Route 25 GEORGE D.SOLOMON (cor.Main Rd. &Youngs Ave.) JOSEPH L.TOWNSEND �l�'COU '`` Southold, NY Telephone: 631 765-1938 Fast: 631 765-3136 PLANNING BOARD OFFICE TOWN OF SOUTHOLD October 6,2008 Kinlin,Rutherford Architects OCT T 2 ATT. Bruce Kinlin 19 Union Square west, 6'floor 6LDG. DEPT. New York,NY 10003 T WN F 50 1rk Q RE: Fishers Island Community Center SCTM# 1000-12-1-5.1. Dear Mr.Kinlin: The Planning Board has reviewed your letter requesting final approval for the Fishers Island Community Center dated October 3,2008 and has found that the.work done to date is in accordance with the approved site plan. As indicated in your letter,the chain link fence will be installed on October 7,2008 and your office will submit photographs following completion. Any future requested change should include a copy of the relevant section of the approved stamped site plan noting the location of the requested change. Should you have any questions regarding the above,please do not hesitate to contact this office. Thank you. Sin er ly, Kristy Winser Senior Planner cc: Planning Board 1� �iL'I ty; 1Lef=R'.111d1T1g=Tt2 Ye�to.. Jamie Richter, Town Engineer ,,. APPEALS BOARD MEMBERS �rjF S0 Mailing Address: o� Ruth D. Oliva. �� p! Southold Town Hall 53095 Main Road •P.O. Box 1179 )� x' Gerard P. Goehringer Southold,NY 11971-0959 James Dinizio, Jr. Chauman G • o Office Location: Michael A. Simon �pl Town Annex/First Floor,North Fork Bank Leslie Kanes Weisman 00um, 54375 Main Road(at Youngs Avenue) Southold,NY 11971 http://southoldtown.northfork.net ZONING BOARD OF APPEALS -. TOWN OF SOUTHOLD . Y'\ Tel. (631)765-1809 •Fax (631) 765-9064 E FEB - 7 i— FINDINGS AND DETERMINATION MEETING OF JANUARY 25, 2007 ZBA SE#5990— FIDCO and FISHERS ISLAND COMMUNITY CENTER, INC. Property Location: Fox Lane Building#98 and Greenwood Road, Fishers Island District 1000 Section 12 Block 1 Lot 5.1 CTM 12-1-5.1 FINDINGS OF FACT PROPERTY FACTS/DESCRIPTION: The applicant's property consists of 1.28+/- acres with 71.93 feet along Greenwood Road and 157.57 feet along Fox Lane, Fishers Island. The building is referred to as Building #98, and is shown on the site development map prepared by CME Associates dated 6/23/2006, revised 8/31/2006. APPLICANT'S REQUEST/BASIS OF APPLICATION: The applicant, Fishers Island Community Center, Inc. (FICC) is a New York State Not-For-Profit Corporation. FIDCO is the current property owner. The applicant FICC requests a Special Exception under Code Section 280-48B (6, 8) for the purpose of converting the existing industrial building into a new non-profit, recreational facility and (nonprofit) meeting hall with storage and office areas. All parking and screening will be determined by the Southold Town Planning Board as provided under the Zoning Code site plan regulations for the General B Business Zone District. SUFFOLK COUNTY ADMINISTRATIVE CODE: This application has been referred as required under the Suffolk County Administrative Code Sections A 14-14 to 23, and the Suffolk County Department of Planning reply dated January 9, 2007 states that the application is considered a matter for local determination as there appears to be no significant county-wide or inter- community impact. STANDARDS/REASONS FOR BOARD ACTION: After review of the requirements set forth pursuant to Chapter 280 governing the proposed community center uses, and on the basis of testimony presented and personal inspection, the Board finds: 1. The requested uses for the new Island Community Center are permitted in this B General Business Zone District under Section 280-48B of the Town Zoning Code, subject to special exception authorization of the Zoning Board of Appeals. In this review the Board-determines-that the uses will be conducted within the existing building (for meeting, exercise, recreational and educational functions and administrative offices, all under the purpose and functions of the Fishers Island Community Center, Inc. This use will be in harmony with the zoning ordinance and will not adversely affect the neighborhood when meeting the code requirements. Page 2—January 25, 2007 _ ZBA SE#5990—FIDCO and FI Community Center CTM 12-1-5.1 2. In addition, the Board has reviewed the General Standards governing Special Exception uses set forth in Section 280-142 and finds that: A) The use of the property for the requested uses in this existing two-story building will not prevent the orderly and reasonable use in this zone district and adjacent districts. The applicant confirmed that the building is presently used for business storage and light-industrial storage uses and related activities. B) This use will not prevent orderly and reasonable use of permitted or legally established uses in this zone district or adjacent use district. C) The safety, health, welfare, comfort, convenience, and the order of the town will not be adversely affected by the proposed use and its location. D) The use will be in harmony with and will promote the general purposes and intent of the code provisions in effect under Chapter 280. E) The use is compatible with its surroundings and with the character of the neighborhood and of the community in general, particularly with regarding to visibility, scale and overall appearance. F) The structures, equipment and material will be accessible for emergency protection. In making this determination, the Board has also reviewed other matters under Section 280-143, and finds that no adverse conditions will result from this authorization: A. There will be no adverse change in the character of the existing and probable development of uses in the district and the peculiar suitability of such district for the location of such permitted uses. B. Property values will be conserved. A non-commercial community center in this B-Business Zone is a listed authorized use in the Zoning Code, allowed by Special Exception approval from the Board of Appeals and site plan approval from the Planning Board. C. The location of the proposed building will not cause traffic congestion on public streets, highways and sidewalks. D. There is availability of adequate and proper public or private water supply and facilities for the treatment, removal or discharge of sewage, refuse or other effluent (whether liquid, solid, gaseous or otherwise) as a result of this use. E. The use or the materials incidental thereto will not give off obnoxious gases, odors, smoke or soot. Outside storage of landscaping or construction debris is not permitted as a condition to this Special Exception. 1� • Page 3—January 25, 2007 • ZBA SE#5990—FIDCO and FI Community Center CTM 12-1-5.1 F. The use will not cause disturbing emissions of electrical discharges, dust, light, vibration or noise. G. The operations as a non-profit community center will not cause undue interference with the orderly enjoyment by the public of parking or of recreational facilities, existing or proposed by the town or by other competent governmental agencies. H. Off-street parking of vehicles incidental to the use and whether such space is reasonably adequate and appropriate is subject to review and approval of the Southold Town Planning Board under the site plan regulations. I. There is no evidence to show that there will be any hazard to life, limb or property because of fire, flood, erosion or panic by reason of or as a result of the use or by the building to be used, or by the accessibility of the property or structures thereon for the convenient entry and operation of fire and other emergency apparatus. There will not be undue concentration or assemblage of persons upon such plot in the operations as a community center. J. The use and the building location will not cause an overcrowding of land or undue concentration of population. K. The plot area has been deemed sufficient, appropriate and adequate for this use. L. The use is not unreasonably near a school, theater, recreational area or other place of public assembly. M. The site is suitable for the proposed building use alterations and conversion and related accessory uses considering its size and the character of the neighborhood. N. No evidence has been presented to show that there would be any detrimental impact to adjacent properties and land uses. O. Adequate provision has been made for the collection and disposal of storm-water runoff, sewage, refuse, solid, and liquid waste. There will be no gaseous waste generated from this conversion of use. P. The natural characteristics of the site are such that the.proposed use may be introduced without undue disturbance or disruption of important natural features, systems or processes and without risk of pollution to groundwater and surface waters on and off the site. RESOLUTION OF THE BOARD: In considering all of the above factors and applying the balancing test under New York Town Law 267-B, motion was offered by Chairman Dinizio, Page 4—January 25,2007 ZBA SE#5990—FIDCO and FI Community Center CTM 12-1-5.1 seconded by Member Goehringer, and duly carried, to GRANT the Special Exception, as applied for, as shown on the floor plans prepared by Bruce D. Kinlin, R.A. last dated 9-1-2006 and site development map prepared by CME Associates dated 6/23/2006, revised 8/31/2006. Vote of the Board: Ayes: Members Dinizio (Chairman), Oliva, Goehringer, Simon, and Weisman. This Resolution was duly adopted (5-0). ames Dinizio Jr., C airma o2 /It /2007 Approved for Filing y� r TOWN OF SOUTHOLD PROPERTY RECORD " CARD OWNER STREET VILLAGE DIST. SUB. LOT 4 ^Y Je [ l FORMER OWNER N oy!zl E ACR. S W TYPE OF BUILDING I�uC ® .tA Conn. I 0 h kv m;' s pub a RES. SEAS. VL. FARM COMM. CB. MILS. Mkt. Value d ra o t te) 48-0 "LAND IMP. TOTAL DATE REMARKS c, o Fc.> I E f `T S,A. ' Tillable. FRONTAGE ON WATER �Za 5 Jam . ® c -F .. J Woodland FRONTAGE ON ROAD Meadowland DEPTH P 07 4.7 House Plot BULKHEAD Total I 1AMMEEMMEMEREEMME ENE r4 "�AeL'k➢v�..-2 a M,, .._.av�aW.. ■■■!■�■!■■�■■�i �■� ■E■■■■ ME■■E■■ E■■■■ M. B Foundation Extension Interior Finish Fire P-1.ace �® Rooms 1st Floor =�I-Driveway .. v Permit# Permit Date COMcheck Software version 3.1 Release 1 Envelope Compliance Certificate New York State Energy Conservation Construction Code Report Date:02/07/06 Data filename:\\Server\l-Kinlin Rutherfurd Architects\1-ACTI-1\46-FIS-1\DOC\FISHER-1.CCK Section 1: Project Information Project Title:Fisher's Island Community Center Construction Site: Owner/Agent: Designer/Contractor: Fisher's Island,NY Kinlin Rutherfurd Architects 145 West 30th Street New York,NY 10001 212-695-2988 bruce@kinlinrutherfurd.com Section 2: General Information Building Location(for weather data): Suffolk,New York Climate Zone: 11b Heating Degree Days(base 65 degrees F): 5750 Cooling Degree Days(base 65 degrees F): 715 Project Type: New Construction Glazing Area Percentage: 8% Building Type Floor Area Other 7992 Section 3: Requirements Checklist Climate-Specific Requirements: Component Name/Description Gross Area Cavity Cont. Proposed Budget or R-Value R-Value U-Factor U-Factor Perimeter Exterior Wall 1:Solid Concrete or Masonry>8",Furring:Metal 5586 i 0.0 13.6 0.063 0.090 Door 2:Glass,Clear,SHGC 0.24 21 -- -- 0.320 0.598 Door 1:Glass,Clear,SHGC 0.24 21 — --- 0.320 0.598 Window 30:Metal Frame with Thermal Break:Double Pane with 14 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 29:Metal Frame with Thermal Break:Double Pane with 14 --- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 28:Metal Frame with Thermal Break:Double Pane with 14 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 27:Metal Frame with Thermal Break:Double Pane with 14 --- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 26:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 25:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 24:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Fisher's Island Community Center Page 1 of 4 v , Window 23:Metal Frame with Thermal Break:Double Pane with 26 --- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 22:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 21:Metal Frame with Thermal Break:Double Pane with 26 --- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 20:Metal Frame with Thermal Break:Double Pane with 26 --- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 19:Metal Frame with Thermal Break:Double Pane with 26 --- - 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 18:Metal Frame with Thermal Break:Double Pane with 26 --- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 17:Metal Frame with Thermal Break:Double Pane with 26 - --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 16:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 15:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 14:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 13:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 12:Metal Frame with Thermal Break:Double Pane with 26 - --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 11:Metal Frame with Thermal Break:Double Pane with 26 --- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 10:Metal Frame with Thermal Break:Double Pane with 19 --- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 9:Metal Frame with Thermal Break:Double Pane with Low-E, 19 -- -- 0.350 0.598 Clear,SHGC 0.29 Window 8:Metal Frame with Thermal Break:Double Pane with Low-E, 19 -- -- 0.350 0.598 Clear,SHGC 0.29 Window 7:Metal Frame with Thermal Break:Double Pane with Low-E, 19 -- -- 0.350 0.598 Clear,SHGC 0.29 Window 6:Metal Frame with Thermal Break:Double Pane with Low-E, 19 -- -- 0.350 0.598 Clear,SHGC 0.29 Window 5:Metal Frame with Thermal Break:Double Pane with Low-E, 19 -- -- 0.350 0.598 Clear,SHGC 0.29 Window 4:Metal Frame with Thermal Break:Double Pane with Low-E, 19 -- -- 0.350 0.598 Clear,SHGC 0.29 Window 3:Metal Frame with Thermal Break:Double Pane with Low-E, 19 -- --- 0.350 0.598 Clear,SHGC 0.29 Window 2:Metal Frame with Thermal Break:Double Pane with Low-E, 19 --- -- 0.350 0.598 Clear,SHGC 0.29 Window 1:Metal Frame with Thermal Break:Triple Pane with Low-E, 19 -- -- 0.350 0.598 Clear,SHGC 0.29 Exterior Wall 8:Solid Concrete or Masonry-8",Furring:None 533 --- 0.8 0.360 0.090 Exterior Wall 7:Solid Concrete or Masonry-8",Furring:None 533 --- 0.8 0.360 0.090 Exterior Wall 6:Solid Concrete or Masonry-8",Furring:None 2357 --- 0.8 0.360 0.090 Exterior Wall 5:Solid Concrete or Masonry-8",Furring:None 2357 -- 0.8 0.360 0.090 Exterior Wall 4:Solid Concrete or Masonry>8",Furring:Metal 1081 0.0 13.6 0.063 0.090 Window 63:Metal Frame with Thermal Break:Double Pane with 20 --- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 65:Metal Frame with Thermal Break:Double Pane with 20 --- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 67:Metal Frame with Thermal Break:Double Pane with 20 -- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 69:Metal Frame with Thermal Break:Double Pane with 20 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 71:Metal Frame with Thermal Break:Double Pane with 20 - --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 73:Metal Frame with Thermal Break:Double Pane with 20 -- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 72:Metal Frame with Thermal Break:Double Pane with 20 --- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 70:Metal Frame with Thermal Break:Double Pane with 20 --- - 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 68:Metal Frame with Thermal Break:Double Pane with 20 --- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 66:Metal Frame with Thermal Break:Double Pane with 20 --- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 64:Metal Frame with Thermal Break:Double Pane with 20 --- --- 0.350 0.598 Fisher's Island Community Center Page 2 of 4 Low-E,Clear,SHGC 0.29 Window 62:Metal Frame with Thermal Break:Double Pane with 20 --- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Exterior Wall 3:Solid Concrete or Masonry>8",Furring:Metal 1081 0.0 13.6 0,063 0.090 Door 8:Solid 21 -- --- 2.000 0.142 Door 7:Solid 21 - - 2.000 0.142 Window 56:Metal Frame with Thermal Break:Double Pane with 20 --- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 57:Metal Frame with Thermal Break:Double Pane with 20 -- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 59:Metal Frame with Thermal Break:Double Pane with 20 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 61:Metal Frame with Thermal Break:Double Pane with 20 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 60:Metal Frame with Thermal Break:Double Pane with 20 --- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 58:Metal Frame with Thermal Break:Double Pane with 20 -- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Exterior Wall 2:Solid Concrete or Masonry>8",Furring:Metal 5586 0.0 13.6 0.063 0.090 Door 3:Solid 21 -- -- 2.000 0.142 Door 5:Solid 21 -- --- 2.000 0.142 Door 6:Solid 21 -- - 2.000 0.142 Door 4:Solid 21 -- --- 2.000 0.142 Window 31:Metal Frame with Thermal Break:Double Pane with 19 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 34:Metal Frame with Thermal Break:Double Pane with 19 --- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 33:Metal Frame with Thermal Break:Double Pane with 19 -- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 32:Metal Frame with Thermal Break:Double Pane with 19 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 35:Metal Frame:Double Pane with Low-E,Clear,SHGC 0.29 19 -- -- 0.350 0.598 Window 39:Metal Frame with Thermal Break:Double Pane with 26 -- - 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 43:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 47:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 51:Metal Frame with Thermal Break:Double Pane with 14 --- --- 0.350 '0.598 Low-E,Clear,SHGC 0.29 Window 55:Metal Frame with Thermal Break:Double Pane with 11 -- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 54:Metal Frame with Thermal Break:Double Pane with 11 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 53:Metal Frame with Thermal Break:Double Pane with 14 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 52:Metal Frame:Double Pane with Low-E,Clear,SHGC 0.29 14 -- -- 0.350 0.598 Window 50:Metal Frame with Thermal Break:Double Pane with 14 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 49:Metal Frame with Thermal Break:Double Pane with 14 -- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 48:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 46:Metal Frame with Thermal Break:Double Pane with 26 --- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 45:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 44:Metal Frame with Thermal Break:Double Pane with 26 - -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 42:Metal Frame with Thermal Break:Double Pane with 26 -- -- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 41:Metal Frame with Thermal Break:Double Pane with 26 -- - 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 40:Metal Frame with Thermal Break:Double Pane with 26 --- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 38:Metal Frame with Thermal Break:Double Pane with 26 --- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 37:Metal Frame with Thermal Break:Double Pane with 26 --- --- 0.350 0.598 Low-E,Clear,SHGC 0.29 Window 36:Metal Frame:Double Pane with Low-E,Clear,SHGC 0.29 19 -- -- 0.350 0.598 Floor 1:Slab-On-Grade:Unheated 480 -- -- -- --- Fisher's Island Community Center Page 3 of 4 Floor 2:Concrete Floor(over unconditioned space) 7996 -- 15.0 0.055 0.055 Roof 2:Structural Slab 7996 -- 15.0 0.062 0.059 Roof 1:All-Wood Joisf/Rafter/Truss 8195 0.0 38.0 0.025 0.059 (a)Budget U-factors are used for software baseline calculations ONLY,and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: ❑ 1. All joints and penetrations are caulked,gasketed,weather-stripped,or otherwise sealed. ❑ 2. Windows,doors,and skylights certified as meeting leakage requirements. ❑ 3. Component R-values&U-factors labeled as certified. ❑ 4. Fireplaces installed with tight fitting non-combustible fireplace doors. ❑ 5. Stair,elevator shaft vents,and other dampers integral to the building envelope are equipped with motorized dampers. ❑ 6. Cargo doors and loading dock doors are weather sealed. ❑ 7. Recessed lighting fixtures are:(i)Type IC rated and sealed or gasketed;or(ii)installed inside an appropriate air-tight assembly with a 0.5 inch'clearance from combustible materials and with 3 inches clearance from insulation material. ❑ 8. Vapor retarder installed. Section 4: Compliance Statement Compliance Statement:The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application.The proposed envelope system has been designed to meet the New York State Energy Conservation Construction Code requirements in COMcheck Version 3.1 Release 1 and to comply with the mandatory requirements in the Requirements Checklist. When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her k owledge, belief,and professional judgment,such plans ors cifications arei incompliance with this Code. �vvc� � �i��'�,•� V1/`-� �. `7 c� to Principal Envelope Designer-Name Signature Dat dCMcc crj,�0. 029a� �O ATE OF i1E� Fisher's Island Community Center Page 4 of 4 o COA44 Q 2 CFNT�� Gin r-- ��� r14 s Ckc& -. G ei_ 4 LAUG - 8 2009 A VNA/ P.O. Box 464 Fishers Island,NY 06390 • 631-788-7990 Fishers Island Community Center,Inc.is a N.Y.state not-for-profit corporation and is a public charity under I.R.S.Section 501 (c)(3)of the code. Tax I.D.number:20-3941546 O 00M4, Q 2 U .� Ms. Heather Lanza August 1, 2008 Town Planning Director 53095 Route 25 P.O. Box 1179 Southold,N.Y. 11971 RE: F. I. Community Center Dear Ms. Lanza: Further to-my conversations with Planning Board member Ken Edwards, this will confirm that we will complete the paving portion of the site plan for our Center no later than June 1, 2009. As Ken mentioned, getting pavers here for a small job is difficult and expensive. As he may have told you, the Main Road on the private east end of the Island is scheduled to be repaved in the Spring, and it would be out intention to complete this part of our project at that time. The planting is being completed today so that is no longer an issue. There has been some discussion with our group about possibly developing some outdoor space in the back of the building on part of the land that is currently paved. At this Pot,; we have no specific plans, but realize that such a change would have to come before Y6 Board for approval. Many thanks for moving this along for us, and we look forward to seeing you next Wednesday. Very truly yours, q2t W. Spofford President P.O. Box 464 Fishers Island,NY 06390 • 631-788-7990 Fishers Island Community Center,Inc.is a N.Y.state not-for-profit corporation and is a public charity under I.R.S.Section 501 (c)(3)of the code. Tax I.D.number:20-3941546 Kinlin Rutherfurd Architects 330 West 38th Street,Suite 1006 New York,NY 10018 212.695.2988 August 4, 2008 Gary Fish Town of Southold Building Department Town Hall Southold, NY 11971 (631)765-1802 Dear Gary, This letter is to certify that the glass used in the interior walls of the Fishers Island Community Center have clear laminated safety glass. The labels have been removed. The glass was purchased from Mystic Mirror& Plate Glass. A copy of the invoice is attached. Best Regards, -f Bruce D. Kinlin,AIA .D-ARCh; • " ���JGED' k � m 2 029Q$� OF N Kinlin Rutherfurd Architects Pi_LC 330 West 381"Street,Suite 1006 New York,NY 10018 212.695,2988 775,582.1736 fax March 12, 2008 Michael Verity Town of Southold Building Department Town Hall Annex Building 54375 Route 25 P.O. Box 1179 Southold NY 11971 Phone: (631) 765-1802 Dear Mr. Verity, Enclosed please find (3) copies of the most updated construction plans for the Fishers Island Community Center, as requested by Building Inspector Gary Fish during his site visit to the project. Sincerely Bruce Kinlin, AIA Fl 1 inN 1 7 %! www.kinlinrutherfurd.com Page 1 of 1 07/31/2008 12:57 631-788-5600 Z S CONTRACTING PAGE 02 'Mystic Mirror roar & Plate Glass • 1 nv61c8 1 4 Edgemont St. 1V�.ystic,.Ct, 06355 DATE INVOICE NO. 536-0015 3/31/2008 15476 BILL TO SHIP TO Z+S Contracting P U Box 202 l!islxers Island NY 06390 Comt cemklu P.i].NO, REPAIR ORD.# TERMS DUE DATE ' Net 30 4/30/2008 DESCRIPTION QTY RATE AMOUNT Clear Laminated Safety Glass - per S.F. 48 1/4' Wire Glass 5 x 26 10 _ r i. . 1 4 t.'• " �.i pro of f�r°' '��� d+•'��"� All Invoices are due on receipt unless otherwise noted. Total E-1Uail Address: nzysticglass@snet.net z3Jbd 2OS6S9LT29T 1d30 9NIa-iine O-10H-inoS bS:OT L002-t72-SO a b� a w � a A LOCATION MAP SCALE 1 "=400' Suffolk County Department of Hoalth Services Approval for Construction-Other Than Single Family Reform we No.0 10"0 G-0-.O 1 Design Flow! Use(s) These pleas have been reviewed 'or general conformance with iZlk County Deportment of Health Services standards,relating to water ca supply and sewage disposal. Regardless of any omissions, izroo� or lack of de 4 cmdnwttms is required to be in accordance w th tbs attached permit coadidons and applicable standards,unless speoNlwlyr wattrod br dta Degar�t.Tldsappmval • 8 PUB hem the appewd a ra waL MAR 0 6 2007 Apprwal ISA R er U Z �C PARKING CALCULAWONS W Z/Z'd 20S6S9LT€9T6:01 92LT28SSLL dd a8njN3HinN NI-1NIN:WONJ U917:OT L002-V2-AUW CONSENT TO INSPECTION fi5kers )s)W bevelobnLen+ Coro . ,the undersigned, do(es)hereby state: Owner(s)Name(s) That the undersigned(is) (are)the owner(s) of the premises in the Town of Southold, located at 9S Fox LAV,e, 'F I SWY S I s l", OW , which is shown and designated on the Suffolk County Tax Map as District 1000, Section 0! 2 'Block I ,Lot 5 . 1 That the undersigned(has) (have) filed, or cause,to be filed, an application in the Southold Town Building Inspector's Office for the following: AI-nva+fi yis -h Wtsfiva VW 14i'M -fir fie, VmWrs I S Ia.►.d a Vn h4MI b Ujn�CV That the undersigned do(es)hereby give consent to the Building Inspectors of the Town of Southold to enter upon the above described property, including any and all buildings located thereon,to conduct such inspections as they may deem necessary with respect to the aforesaid application, including inspections to determine that said premises comply with all of the laws, ordinances,rules and regulations of the Town of Southold. The undersigned, in consenting to such inspections, do(es) so with the knowledge and understanding that any information obtained in the conduct of such inspections may be used in subsequent prosecutions for violations of the laws, ordinances,rules or regulations of the Town of Southold. Dated: O 6 (Signature f IZ�r4tC (•�• � (Print Name) (Signature) (Print Name) Kinlin Rutherfurd Architects PLC 330 West 38t^Street,Suite 1006 New York,NY 10018 212.695.2988 775.582.1736 fax April 24, 2007 Michael Verity Town of Southold Building Department Town Hall P. 0. Box 1179 Southold, NY, 11971 Michael, Attached please find 4 copies of the structural drawings for the Fishers Island Community Center Project(S100&S101). Sorry to be sending the drawings separately,we apologtessffor any inconvenience. We will be sending you the MEP drawings as soon as possible. Thanks and best regards, Flavia Da Silva ;1 APR 2 �,.,, , r 5 T i i www.kinlinrutherfurd.com Page 1 of 1 NYS UNIFORM FIRE PREVENTION AND BUILDING CODE. COMMERCIAL & MULTIPLE DWELLING.000UPANCIES` NYS BUILDING CODE (B) Date: NYS FIRE;CODE.(F) Reviewer: NYS PLUMBING CODE(P) NYS MECHANICAL.CODE (M) Building: NYS FUEL GAS CODE (FG) Location: NYS ENERGY CODE (E) No: Topic Section. ,Req'.d :or Allowed Actual 1 Occupancy B-302 2 Type of Construction B-Table 601 3 Height & Bldg Area B-503 Tabular Area B-Table 503 (, l Stories allowed Tabular Height 3/ 4 Height Modifications B-504 Sprinkler Tabular Height(feet) �✓� Tabular Height (story) Increase Allowed Total Height Allowed 5 Area Modifications B-506 (See work sheet) Area increase formula Eq 5-1 Frontage B-506.2 Eq 5-2 (P) perimeter of bldg (F) frontage of bldg (W)width, open space Sprinkler B-503.3 Single story 300% Multi story 200% Total Area Allowed Page 1 of 8 No Topic Section Req'd or Allowed Actual 6 Atriums B=404 Definition B-.404.1.1 Sprinkler Protection B-4043 Smoke Control B=404.4 / Enclosure B-404.5 Auto Fire Detection 6-404.6 Interior Finish B-404.8 Travel Distance B-404:9 7 Distance.Separation B-Tb1602 Exterior Wall Openings B-Tb1704.8 8 Fire Rated Const'n Incidental Use Areas B-TbI 302.1.1 Accessory,Occupancy B-302.2 Mixed Occupancy B-TbI 302.3.3 Z Fire Walls B=705. '✓ Fire Barrier B-706 Shaft Enclosure B-707 Fire Partition B-708 Smoke Barriers B-709 Opening Protectives B TbI 714.2 Fire Blocking B-716 Draft Stopping B-716.3 Interior Finishes B-TbI 803.4 9 Interior:Environment Min. Rm. Dimensions B-1207.1 Min. Ceiling Height B-1207.2 Ventilation B-1202.1 Light B-1204.1 Page 2 of 8 .No Topic Section Req'd or Allowed Actual 10; Exits -.Occupant Load B Tbl A003.2.2 One Exit Permitted B Tbl 1005.2.2 Egress Width 13- 1003.2.3 (per occupant) Ceiling Height B 1003.2.4 Exit Signs B- 1003.2.10 Egress Illumination B-1003.2.11 .11 Egress Components Doors Door Size B- 1.003.3.1.1 Door Swing 13- 1003.3.1.2 Locks/ Latches B- 1003.3.1.8 Panic Hardware B- 1003.3.1'.9 Stairs Width .B-1003.3.3.1 Headroom. B-1003.3.3.2 Tread /Riser B-1003.3.3.3 Vertical Rise B-1003.3.3.6 Handrails B-1003.3.3.11 12 Exit Access Remoteness B-1004.2.2.1 Travel Distance B-1004.2.4 Corridors Fire Rating B-1004.32.1 Width B-1004.3.2.2 Dead ends B-1004.3.2.3. 13 Exterior Wall Coverings B-Tbl 1405.2 Combustible Finishes B-Tbl 1406.2 14 Roof Assemblies Chapt 15 Material type(s) Page 3 of 8 No Topic .Section,. Req'd "or Allowed Actual 15. Structural' Snow Load:- Ground B Fig :1608.2 .Snow Load,' Roof ASCE 7-98 (calc f Drifting Snow B-16087 Ponding: B-1608,.3.5 Floor Loading B Tbl IWTA Balcony Loading B-T61.16071 Flood Plain B=1603:1;;6 Wind Loading`. B-1609 Seismic Loading(calcj 13-1614. foundation Depth :13-11805:2 16 Swimming Pools B-31.09 17 Electrical Exit Signs B 1003:2.10 f✓Y� '� � � Emergency Lights B-1003.2.11 Emergency:Power B-1003.2.11.2 18 H/C°ACCESS Exempt Buildings 13A 1.04,4 Parking: : B=Tb1 1106.1 Route: BAI 04.1 Entrance. 6-11.05.1 #of Sleeping Rooms B-Tbi-1.1.07:6.1.1 #of:Dwelling Units B-1.107.6.2 Toilet Facilities B-1109.2 Service.Counters B-1109.12.3 P. Supplemental. Appendix E Requirements Page 4 of 8 No Topic Section Req'd or:Allowed Actual 19 Fire Protection Eq'p Sprinkler Systems F-903 Extinguishing Systems F-904 Standpipe Systems F-905 Fire Extinguishers F-906 Fire Alarm Systems F-907 Smoke Detection F-907 Hi-Rise Fire Safety F-907.2.12 Visible Alarms F-Tbl 907.10.1.2 Smoke Control F-909 Smoke Vents F-910 Fire Pumps F-913 Kitchen Hood Ext' F-609.8 20 Plumbing Code Fixture Count P-Tbl 403.1 Water Supply Service Pipe Size P-603 Fixture Pipe Size P-603.1 Pipe Material P-Tbl 604.5 Labor Law Art. 10-A NYS-904.6 Pipe Insulation Energy Code Lawn Irrigation P-608.16.5 Pipe Freezing P-305.6 Sanitary Drainage Drain Pipe Size P-Tbl 709.1 Drain Pipe Material P-702 Vent Size P-Tbl 910.4 Pipe Hangers P-Tbl 308.5 Air Admittance Valves P-917 Page 5 of 8 No Topic Section Req'd or Allowed Actual 21 Mechanical Code Ventilation Rates M-Tb1;403.3 Propane Below Grade M-502:8.10.1 Dryer Exhaust M-504 Kitchen'Exhaust M-506 Kitchen.Hoods M-5Q7, Kitchen Make-Up Air M-508 , Chimney Termination M-Tbl 51.1.2 Air Plenums M-602 . Fire &Smoke Dampers M=607.5.1 Combustion.Air. : M-701` Confined Spaces-Def: M-202 :22 Fuel Gas Code Appliance Location FG-303 .Combustion Air FG-304 Clearance to Combust. FG-Tbl 308.2 Pipe Material FG-403 Shut Off Valves FG-409 Chimney Termination FG=Fig. 503.5.4 Gas'.Vent Termination FG-Fig. 503.6.E Exit Terminal Location FG-503:8 Clothes Dryer Exhaust FG-613 Unvented Room Heater FG-620 23 Energy Code Chapter 7 (ASHRAE) E-701 ,. Chapter 8 Building Envelope E-802 Mechanical System E-803 Service Water Heating E-804 Lighting:and Power E-805 Total Building Pere E-806 l Page 6 of 8 ' S CONCORD COMMERCIAL PART 1- General 1.1 SCOPE To furnish all labor,materials and equipment necessary or required to fully complete the installation of the lift as indicated on the drawings and specifications. This suggested specification is intended to cover the complete installation of the Concord PROLIFT VOYAGER Commercial Wheelchair Lift design. 1.2 SYSTEM DESCRIPTION The lift assembly shall consist of a power unit, car, guide system, 1:2 cable hydraulic lifting device,hoistway doors, control system, signals and alarms, electrical wiring, and parts and accessories necessary to provide required performance, operation, code and safety requirements. 1.3 QUALITY ASSURANCE 1.3.1 The lift shall meet or exceed the applicable regulations of all governing agencies and be in compliance with the applicable sections of the most current edition of the following codes and standards: a)ASME A18.1-2000 "Safety Standard for Platform Lifts and Stairway Chair Lifts" b) CSA B355-00 "Lifts for Persons with Physical Disabilities". c)ICC/ANSI A117.1-1998 "Accessible and Usable Buildings and Facilities". d)ANSI/NFPA 70-1999"The National Electric Code" (NEC). e)ADAAG"Americans With Disabilities Act Accessibility Guidelines" (where applicable). f) CSA B44.1/ASME A17.5 "Elevator and Escalator Electrical Equipment" g)Local codes and regulations, as applicable. 1.3.2 Requirements of the Regulatory Agencies a)Fabricate and install Work in compliance with all applicable jurisdictional authorities. b)File shop drawings and submissions to local authorities as the information is made available. Company pre-inspection and jurisdictional authority inspections and permits are to be made on a timely basis as required. Work will include all inspections and re- inspections that are required to ensure licenses are issued. Concord Elevator, Inc. www.concordelevator.com 107 Alfred Kuehne Blvd. Brampton ON Can.•. L6T 4K3 Tel (905) • 91 • • - 1-800-661-5112 CE-VOYCSPC-02 02005 CONCORD � COMMERCIAL 1.3.3 Subcontractor Qualifications a)Execute work of this specification only by a contractor/company who has adequate product and public liability insurance in excess of one million dollars. b) Skilled tradesmen must be employees of the contractor to perform the work on a timely basis. Employees must be trained by the manufacturer and be supervised by the lift contractor. 1.3.4 Substitutions No substitutions will be considered unless written request for approval has been submitted by the bidder and received by the architect at least 10 days before the date of receipt of bids. Each such request shall include a complete description of the proposed substitute including drawings,test data,photographs, and any other information needed for consideration. Part 2- Preparatory Work by Others 2.1 The following preparatory work to accommodate/receive the lift is to be done by others: 2.1.1 Power unit machine room to meet applicable codes and standards. 2.1.2 Permanent power to operate the lift to be provided to a Lockable Fused/Cartridge Type Disconnect switch with auxiliary contact/switch for emergency battery lowering. Provide 115-volt lighting supply and disconnect. Refer to architectural drawings for permanent power specifications and location of the disconnect. 2.1.3 Provide appropriate sleeves for both the electrical conduit and hydraulic line from the power unit enclosure to the hoistway (as shown on drawings). Trenching may be required if the machine room is not adjacent to hoistway. 2.1.4 Provide power unit enclosure light and light switch, located to comply with applicable codes and standards. 2.1.5 Provide an enclosed,plumb and square hoistway with smooth interior surfaces. Include for fascias or furring of hoistway interior where applicable. Concord Elevator, Inc. www.concordelevator.com CE-VOYCSPC-02©2005 CONCORD • COMMERCIAL 2.1.6 Provide a framed and enclosed legal hoistway, including power unit enclosure, as required by the governing code or authority. 2.1.7 Provide landing entrances. a) Suitable lintels over landing entrances are to be provided. b)Provide rough openings as per lift contractors' shop drawings. 2.1.8 Provide substantially level pit floor slab to support loads indicated on the lift contractors' shop drawings. 2.1.9 Provide adequate support for guide rail fastenings. 2.1.10 Provide light, receptacle and switch in pit, located to comply with applicable Code. 2.1.11 Provide pit water proofing or sump pump, if required, as allowed by Code. 2.1.12 Provide pit ladder for pits 3'- 0" (914 mm) or more in depth. 2.1.13 Provide finish grouting and masonry around doorframes. 2.1.14 Provide finish painting of landing entrances. Part 3 - Submittals 3.1 SHOP DRAWINGS The shop drawings shall show a complete layout of the lift equipment detailing dimensions, clearances and location of machinery. Including,but not limited to,the following: 3.1.1 Drawings showing the dimensions including plans, elevations, and sections to show equipment locations. Concord Elevator, Inc. www.concordelevator.com CE-VOYCSPC-02©2005 SCO COMMERCIAL 3.1.2 Load and reaction drawings shall be provided by the lift manufacturer and detailed on drawings. Part 4 - Product Data 4.1 MANUFACTURER/PRODUCT Lift shall be the CONCORD PROLIFT VOYAGER Commercial Wheelchair Lift manufactured by Concord Elevator Inc. Toll Free Number 800 661-5112 and(905) 791- 5555,Fax(905) 791-2222 Rated Load: 1,400 lbs. (635 kg.) Rated Speed: 30 fpm (0.15 m/s) Car Dimension: 47"W x 60"D (1194 W x 1524 D mm) Operation: Constant pressure or automatic (where permitted) floor selective Power Supply: 220 Single Phase, 50 Amps or 208 Three Phase, 30 Amps Travel Distance: 50 feet(15m)Maximum where permitted, (13355-approx 23 ft (7m)Maximum) Levels Served: Maximum 4 Number of Openings: Maximum 2 Lighting Supply: 110-Volt, Single Phase, 60 Cycle, 15 Amps Door Opening: 35"x 6'-8" (890 x 2030 mm)Nominal Jack Type: 1:2 Cable Hydraulic Pump Type: Submersible Type Door Type: Pro-Auto Door, 2 hr. UL/ULC Fire Rated Door Leveling Device Type: Magnetic Floor Scanner 4.2 SIGNAGE 4.2.1 The lift shall have all necessary signs, capacity plates, and data signs as per the Local and National Codes and Standards. 4.2.2 A capacity plate indicating the rated load in pounds and kilograms and operating instructions shall be furnished by the manufacturer and fastened in a prominent place at each landing and in the cab. The capacity plate and operating instructions will be engraved on non-glare,micro-surface,white letters on a blue background, self-adhesive, flexible plastic material. The letters and figures stating the capacity shall not be less than 1/4"in height. Concord Elevator, Inc. www.concordelevator.com 107 Alfred Kuehne Blvd. Brampton ON Canada L6T 4K3 Tel (905) • 91 • • 1-800-661-5112 CE-VOYCSPC-02 02005 S.'CONCOIR7 COMMERCIAL 4.3 CAR ENCLOSURE 4.3.1 Walls MCP melamine panels 1/2" (13 mm)with clear anodized aluminum trim. 4.3.2 Ceilings Architectural white painted steel frame,with four(4) incandescent down lights. 4.3.3 Floor Steel frame with Plywood sheeting. 4.3.4 Handrail One (1) stainless steel handrail shall be located on control wall of the cab. 4.3.5 EMERGENCY OPERATION The car shall be equipped with a battery that will power an emergency lowering device, unlock door and power an alarm in the event of failure of the normal building power supply.Battery will be rechargeable with an automatic recharging system. 4.3.6 EMERGENCY LIGHT The car shall be equipped with an integral emergency light that will illuminate automatically in the event of a main power failure. 4.3.7 CAR OPERATING PANEL Car operating panel shall be hinged and consist of one constant pressure metal push button with halo lighting for each landing, an emergency stop and alarm button mounted on a removable stainless steel panel(Type 304#4 stainless steel finish). 4.3.8 CAR LIGHTING The car lighting shall consist of four(4) low voltage incandescent down stainless lights. The failure of one lamp shall not cause the remaining lamps to extinguish. 4.3.9 AUTOMATIC LIGHTS Overhead lights in the car compartment shall turn ON automatically when the lift door is opened and stay ON while the lift is in use. A timer will shut OFF the lift lights when the lift is not in use. Concord Elevator, Inc. www.concordelevator.com Alfred107 Kuehne Blvd. Brampton ON .•. L6T 4K3 Tel (905) • 91 • • - 1-800-661-5112 CE-VOYCSPC-02©2005 'O CONCORD � COMMERCIAL 4.4 PRO AUTO SWING.DOOR ENTRANCES Complete entrance assembly to carry a fire label from UL/LTLC certifying it has been tested and approved for minimum fire separation of two (2)hours. The landing entrances shall be supplied as an integral unit,pre-wired,zinc wipe coated and ready for installation at the site.Each integral landing entrance shall have an automatic swing type power door and have the following equipment included and mounted: 4.4.1 Door vision panel approximately 3"x 26 3/4"(75 x 680mm) of clear wired glass (or to the maximum permitted by the fire label)with aluminum finish frame. 4.4.2 Swing clear non-exposed heavy-duty stainless steel ball bearing hinges. 4.4.3 Interlock shall be provided with an electric contact,which will interrupt the power to the control mechanism if the door is in the OPEN position or if the door is not securely closed and locked. The interlock will prevent movement of the lift when the door is OPEN. 4.4.4. Door to be 35"x 80" (890 x 2030 mm)nominal, swing type. 4.4.5 The door locking mechanism shall be of the concealed type with no visible beak. 4.4.6 Door shall be equipped with aluminum push plate,pull handle and interior kick plates. 4.4.7 Keyed hall call station with a metal push button with halo lighting and a stainless steel cover plate shall be an integral part of each landing doorframe. 4.4.8 The automatic power door operator shall be concealed type,with accurate and adjustable speed control and pressure sensitivity. 4.4.9 Lock shall be time delayed electrically controlled for vandal resistant security. Concord Elevator, Inc. www.concordelevator.com 107 Alfred Kuehne Blvd. Brampton ON Canada L6T 41<3 Tel (905) • 91 • • 1-800-661-5112 CE-VOYCSPC-02©2005 '' CONCO COMMERCIAL 4.4.10 Landing sill shall be aluminum checker plate. 4.5 PLATFORM TOE GUARD A platform toe guard shall be provided at each car entrance opening to extend below car entrance opening for safety. 4.6 LEVELING DEVICE 4.6.1 The lift shall be provided with a 2 way leveling device which will maintain the car within 1/2" (13 mm) of the landing by magnetic sensing. 4.6.2 Leveling device switches shall be located in a position to be inaccessible to unauthorized persons (i.e., located behind the cab control wall accessible by removable panel). 4.6.3 All limits shall be mechanically sensed for accurate operation. 4.7 HYDRAULIC POWER UNIT a) The pump and motor shall be the submersible type installed inside the oil tank. b)The controller shall be integrally mounted on the power unit frame and pre-wired and tested before shipment. c) Control circuitry to be"Programmable Logic Controls". d)The power unit control valve shall include all hydraulic control valving inherently. This valve shall incorporate the following features: (i)Up and down acceleration and deceleration speed adjustment for a smooth starts and stops. (ii) Smooth stops at each landing shall be an inherent feature of the valve. (iii)Adjustable pressure relief valve. (iv)Manually operating DOWN valve to lower elevator in an emergency. (v)Pressure gauge indicating in P.S.I. and Bars. (vi) Gate valve to isolate cylinder from pump unit. (vii)Negative pressure switch 4.8 CYLINDER AND PLUNGER 4.8.1 The cylinder shall be constructed of steel pipe of sufficient thickness and suitable safety margin. The top of the cylinder shall be equipped with a cylinder head with an internal guide ring and self-adjusting packing. 4.8.2 Concord Elevator, Inc. www.concordelevator.com CE-VOYCSPC-02 02005 .4 CONCORQ COMMERCIAL The plunger shall be constructed of a steel shaft of proper diameter machined true and smooth. The plunger shall be provided with a stop electrically welded to the bottom to prevent the plunger from leaving the cylinder. 4.9 CABLE Minimum of two 3/8" (10 mm) cables. Minimum breaking strength 14,400 lbs. each. 4.10 SAFETY DEVICE A"slackibroken cable" safety device shall be supplied,which will stop and sustain the lift and its rated load, if either of the hoisting cables become slack or breaks. The safety device shall be resettable by the operation of the lift in the upward direction.A switch shall be mounted in such a position to sense the operation of the safety device, and will open the safety circuit to the controller to prevent operation of the lift in either direction. 4.11 GUIDE YOKE The 1:2 guide yoke/sheave arrangement shall be supplied with a sheave,guide shoes, roller bearings and adjustable cable guards. The sheave shall be finished with rounded grooves to fit the cables. 4.12 NORMAL TERMINAL STOPPING DEVICES Normal terminal stopping devices shall be mechanically sensed at the top and bottom of runway to stop the car automatically. 4.13 GUIDE RAILS AND BRACKETS 4.13.1 Steel 8lb/ft"T"guide rails and brackets shall be securely fastened to the building structure. 4.13.2 Brackets shall securely hold the guides in a plumb and true position regardless of car loading. Maximum of 4 levels. 4.13.3 Guides shall be bolted through the hoistway enclosure with back-up plates,washers and nuts. Subject to architects' alterations and approvals. Concord Elevator, Inc. www.concordelevator.com 107 Alfred Kuehne Blvd. Brampton ON Canada L6T 41<3 Tel91 91 • • 1-800-661-5112 CE-VOYCSPC-02©2005 CONCO►RQ�' • COMMERCIAL 4.14 CAR SLING 4.14.1 Car sling shall be fabricated from steel members with adequate bracing to support the platform and cab. 4.14.2 The buffer-striking member on the underside of the car must stop the lift before the plunger reaches its down limit of travel. 4.14.3 Guide shoes to be solid slipper type with polyurethane inserts. 4.15 WIRING All wiring and electrical connections shall comply with applicable codes, insulated wiring shall have flame retardant and moisture proof outer covering and shall be run in conduit or electrical wire ways. Traveling cables shall be flexible and suitably suspended to relieve strain. Part 5- Execution 5.1 EXAMINATION All site dimensions shall be taken to ensure that tolerances and clearances have been maintained and meet local regulations. 5.2 PREPARATION Pre-inspect the construction and service requirements for"Work by Others."These requirements will be included in drawings, diagrams, engineering data sheets and special instructions before the work commences. Part 6- Warranty 6.0 Concord Elevator shall provide a Manufacturer's limited parts warranty as outlined in Appendix A. Concord Elevator, Inc. www.concordelevator.com CE-VOYCSPC-02©2005 C0NC0RMAN % bW, S9AV11jff COMMERCIAL Part 7- Owner's and Instruction Manual 7.0 After the installation is completed,the contractor shall instruct the owner in the proper use, operation and maintenance requirements of the lift. Instructions to also include emergency procedures and safety rules and precautions. The contractor should also supply the owner with an Owner's Manual detailing the operating, safety, and maintenance procedures of the lift. Concord Elevator, Inc. www.concordelevator.com 107 Alfred Kuehne Blvd. .d. L6T 41<3 Tel (905) • 91 • - 1-800-661-5112 CE-VOYCSPC-02©2005 Appendix A Concord Elevator Manufacturer's Limited Product Warranty Term of warranty — this warranty is valid for a period of 36 months from the date that the product shipped from our factory. Purchase price for product must be paid in full for manufacturer to release parts under this warranty. Coverage—this warranty applies to the repair or replacement, at Manufacturer's option, of parts that fail due to defective material or workmanship.Manufacturer may, at its option,provide factory reconditioned parts. This warranty is provided to the Authorized Concord Dealer on behalf of the final purchaser of the product and is not transferable. The Manufacturer's warranty does not cover labor charges for the removal,repair or replacement of warranty parts but such costs may be covered for a period of time by Authorized Dealer's warranty,which is provided to purchaser separately. Conditions: 1) This warranty only applies to products installed and maintained by a Concord Elevator Authorized Dealer in conformance with all applicable local and national codes. 2) The warranty is void if regular inspection and maintenance of product is not being carried out by an Authorized Concord Dealer in accordance with the recommendations contained in the Owner's Manual. It is the Owner's responsibility to keep records of all such service. 3) This warranty does not apply to the following: 1) Consumable items which include: light bulbs, batteries, oil seals, mechanical switches, guide shoe inserts,drive belts,hydraulic fluids,greases,oils etc. 2) Structural or cosmetic components that are subject to normal wear and tear, external forces and/or misuse. This includes metal panels, glass, plexiglass, gates, doors, buttons, switches,upholstery,trim etc 3) Items that require periodic assessment,maintenance and/or replacement.This includes paint,caulking, weather seals,etc 4) Malfunction or damage to product caused by accident, misuse, abuse or vandalism, lack of proper maintenance, improper installation or placement of product, neglect, improper adjustment, modification or alteration, structural condition of building or hoistway, overloading, failure to follow operating instructions or acts of God. Standard Procedures: Required warranty parts will be shipped at Concord Elevator's expense by UPS ground.Expedited or air shipment of parts is available at Dealer's request and expense. Some parts covered under this warranty may be commercially available from a source close to the job site and Concord will reimburse Dealer for cost to purchase these items provided that approval is obtained from Concord's Technical Support Department in advance. Disclaimers: Concord disclaims liability for any personal injury or property damage resulting from the operation of a product that has been modified from the original Concord design. No person or company is authorized to change the design of this product without written authorization by Concord. Concord's obligation under this warranty is exclusively limited to the repair or exchange of parts that fail within the applicable warranty period. Concord assumes no responsibility for expenses or damages, including incidental or consequential damages. Some states and/or provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you. . 1 TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey www. northfork.net/Southold/ PERMIT NO. Check Septic Form N.Y.S.D.E.C. Trustees Examined &Ilk ,20 0-7 Contact: Approved ,20_GL,7 Mail to: Oruce klni)n Disapproved a/c Klrlllh Ix11ntV d�lydnrkClT Phone: 3 30 W. 3 8fi" S+ Sui4e (c cG Expiration 20bL New 40yr Nq too(S Building Inspector APPLICATION FOR BUILDING PERMIT Date �{ I , 20 0 7 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the'construction of buildings, additions, or alterati' or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. r v (Signature of applicant or name,if a corporation) Kl�lin RU14•erfiv� ,¢r�„i�ds, p�t.0 3.30 W• 3 8'u S1'•/t lac(o , New gc;yk , Nq lo.o( (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder .�rYG1�1 i PCs+' Name of owner of premises �1nS grs Js Jgitd beyel0pnVnJ Coirpo oy) e F 112CO (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer �Ir/Un k W. Bttirr (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: 98 f Ox La.rle. i stieys 1S)" , N House Number Street Hamlet County Tax Map No. 1000 Section 012. Block I Lot 5 Subdivision Filed Map No. Lot (Name) i 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy I►jdu.Skrieej Li�k+) S+yrzwe Gevi 131ASInesS b. Intended use and occupancy CorhmeY- a l Kea-rabho h i Yoeefi�a AA II CNoh -- PY-P f 3. Nature of work(check which applicable): New Building Addition Alteration ✓ Repair ✓ Removal Demolition Other Work (Description) 4. Estimated Cost .21 -750A 0 00 Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units N/A Number of dwelling units on each floor N f A If garage, number ofcars /A 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. Community Ce,14r-y' 7. Dimensions of existing structures, if any: Front 202 ' Rear 202 ' Depth 41 Height . 2 %'-lv" Number of Stories 2- Dimensions of same structure with alterations or additions: Front 202 ' Rear 2o2 Depth 41 ' Height 28 '-l0 '' Number of Stories 2 8: Dimensions of entire new..construction: Front NlA Rear N/A Depth N/A Height N/A Number of Stories N/A 9. Size of lot: Front 21501 Rear 2 3 2 ' Depth 901 10. Date of Purchase rs/A Name of Former Owner /A 11. Zone or use district in which premises are situated b1si�-iG�' 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO v' Will excess fill be removed from premises? YES NO ✓ bYAWCY � 14. Names of Owner of premises r 1 DC 0 Address rishers Islam,ttul qv3jo Phone No. 60)- 188- Name of Architect kinl i n IZutky-$wd AvcV icds ty_Address 33o w•38,o l om N Y.NY Phone No 2 I Z-[.q a 9 8$ Name of Contractor Z k S cov rachyW Address P.p. ft 2a Phone No. L31 -�8g -1g 5'1 i✓KMers Island,Nt1 CIo390 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO V * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OFIiIEW o pjrtACC 12 . k 1101 i n being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the +,m - (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief, and that the work will be performed in the manner set forth in the application filed therewith. Sworn to bef9re me this `8 day of 20� Notary Public Signature of Applicant ROBERT E.GROSS Notary Public, State of Now York No. 30-4636487 Oualified in Nassau Gount+j Comi-nission Expires March 30, 200 866.DLI.7078 INDOOR AIR QUALITY TOLL FREE HVAC NOISE CONTROL 860.889.7078 T LIGHTING sin Y 860.204.0419 F ELECTRICAL earned 116 MAIN STREET PLUMBING Yv ° Inc. NORWICH,CT 06360 FIRE PROTECTION S e urlists inAninud WWW.DESIGNLEARNED.COM Care Facil%tti Engineering iJ Fishers Island Community Center �t M/E/P SPECIFICATIONS 5/8/07 to . l � i _ MEMBERS: AMERICANBOARDINGKENVELSASSOCIATION.HUMANESOCIETYOF THE UMTEDSTATES Ll U� A 4 4 J SECTION 01300 ADMINISTRATIVE REQUIREMENTS -' PART1 GENERAL �J�( 1.01 SECTION INCLUDES A. Submittals for review and information. B. Number of copies of submittals. C. Submittal procedures. 1.02 PROJECT COORDINATION 1'h A. Make the following types of submittals to Design Learned, Inc.: 1. Requests for interpretation. 2. Requests for substitution. 3. Shop drawings, product data, and samples. 4. Test and inspection reports. 5. Manufacturer's instructions and field reports. 6. Applications for payment and change order requests. 7. Progress schedules. 8. Coordination drawings. PART2 PRODUCTS-NOT USED PART 3 EXECUTION 3.01 SUBMITTALS FOR REVIEW 4 A. When the following are specified in individual sections, submit them for review: 1. Product data. j' 2. Shop drawings. 3. Samples for selection. 4. Samples for verification. B. Submit to Design Learned, Inc. for review for the limited purpose of checking for conformance with information given and the design concept expressed in the contract documents. 'N C. Samples will be reviewed only for aesthetic,color, or finish selection. I D. After review, provide copies and distribute in accordance with SUBMITTAL PROCEDURES article below. 3.02 SUBMITTALS FOR INFORMATION A. When the following are specified in individual sections, submit them for information: 1. Design data. 2. Certificates. 3. Test reports. 4. Inspection reports. 5. Manufacturer's instructions. 6. Manufacturer's field reports. 7. Other types indicated. 3.03 SUBMITTALS FOR PROJECT CLOSEOUT A. Submit the following at project closeout: (i 1. Project record documents. Fishers Island Community Center 01300 - 1 10/20/2006 ADMINISTRATIVE REQUIREMENTS i? 2. Operation and maintenance data. II 3. Warranties. l 3.04 NUMBER OF COPIES OF SUBMITTALS A. Documents for Review: r 1. Small Size Sheets, Not Larger Than 8-1/2 x 11 inches: Submit the number of copies which the Contractor requires, plus two copies which will be retained by the Design Learned, Inc.. —� 2. Larger Sheets, Not Larger Than 36 x 48 inches: Submit the number of opaque reproductions which Contractor requires, plus two copies which will be retained by Design Learned, Inc.. B. Documents for Information: Submit two copies. C. Documents for Project Closeout: Make one reproduction of submittal originally reviewed. Submit one extra of submittals for information. 1 D. Samples: Submit the number specified in individual specification sections; one of which will be retained by Design Learned, Inc.. 1. After review, produce duplicates. - 2. Retained samples will not be returned to Contractor unless specifically so stated. 3.05 SUBMITTAL PROCEDURES A. Sequentially numberthe transmittal form. Revise submittals with original number and a sequential alphabetic suffix. j B. Identify Project, Contractor, Subcontractor or supplier; pertinent drawing and detail number, and specification section number, as appropriate on each copy. r C. Apply Contractor's stamp, signed or initialed certifying that review, approval, verification of Products required,field dimensions, adjacent construction Work, and coordination of information is in accordance with the requirements of the Work and Contract Documents. D. Deliver submittals to Design Learned, Inc. at business address. E. Schedule submittals to expedite the Project, and coordinate submission of related items. F. For each submittal for review,allow 15 days excluding delivery time to and from the Contractor. G. Identify variations from Contract Documents and Product or system limitations which may be - detrimental to successful performance of the completed Work. H. Provide space for Contractor and Design Learned, Inc. review stamps. II I. When revised for resubmission, identify all changes made since previous submission. 4 !f J. Distribute copies of reviewed submittals as appropriate. Instruct parties to promptly report any inability to comply with requirements. K. Submittals not requested will not be recognized or processed. END OF SECTION t , Fishers Island Community Center 01300 -2 j 'i 10/20/2006 ADMINISTRATIVE REQUIREMENTS �1 SECTION 01600 PRODUCT REQUIREMENTS i PART1 GENERAL 1.01 SECTION INCLUDES A. Transportation, handling, storage and protection. 4 B. Product option requirements. C. Substitution limitations and procedures. D. Spare parts and maintenance materials. 1.02 SUBMITTALS A. Proposed Products List: Submit list of major products proposed for use,with name of manufacturer, trade name, and model numberof each product. 1. Submit within 15 days after date of Agreement. 2. For products specified only by reference standards, list applicable reference standards. B. Product Data Submittals: Submit manufacturer's standard published data. Mark each copy to identify applicable products, models, options, and other data. Supplement manufacturers' standard data to provide information specific to this Project. r� C. Shop Drawing Submittals: Prepared specifically for this Project; indicate utility and electrical characteristics, utility connection requirements,and location of utility outlets for service for functional equipment and appliances. D. Sample Submittals: Illustrate functional and aesthetic characteristics of the product, with integral parts and attachment devices. Coordinate sample submittals for interfacing work. 1. For selection from standard finishes, submit samples of the full range of the manufacturer's standard colors,textures, and patterns. E. Indicate utility and electrical characteristics, utility connection requirements, and location of utility outlets for service for functional equipment and appliances. PART2 PRODUCTS 2.01 EXISTING PRODUCTS A. Do not use materials and equipment removed from existing premises unless specifically required or permitted by the Contract Documents. B. Reused Products: Reused products include materials and equipment previously used in this or l r other construction, salvaged and refurbished as specified. 1 U 2.02 NEW PRODUCTS A. Provide new products unless specifically required or permitted by the Contract Documents. 2.03 PRODUCT OPTIONS A. Products Specified by Reference Standards or by Description Only: Use any product meeting those standards or description.Submit for approval. B. Products Specified by Naming One or More Manufacturers: Use a product of one of the manufacturers named and meeting specifications, no options or substitutions allowed. C. Products Specified by Naming One or More Manufacturers with a Provision for Substitutions: Submit a request for substitution for any manufacturer not named. Submit for approval. - r Fishers Island Community Center 01600 - 1 10/20/2006 PRODUCT REQUIREMENTS I I 2.04 SPARE PARTS AND MAINTENANCE PRODUCTS A. Provide spare parts, maintenance, and extra products of types and in quantities specified in individual specification sections. B. Deliver to Project site; obtain receipt prior to final payment. PART 3 EXECUTION I, I 3.01 SUBSTITUTION PROCEDURES J it A. Document each request with complete data substantiating compliance of proposed substitution with Contract Documents. B. A request for substitution constitutes a representation that the submitter: 1. Has investigated proposed product and determined that it meets or exceeds the quality �- level of the specified product. 2. Will provide the same warranty for the substitution as for the specified product. Jt `il 3. Will coordinate installation and make changes to other Work which may be required for the Work to be complete with no additional cost to Town of Southold. 4. Waives claims for additional costs or time extension which may subsequently become apparent. 5. Will reimburse Town of Southold and Design Learned, Inc. for review or redesign services associated with re-approval by authorities. C. Substitutions will not be considered when they are indicated or implied on shop drawing or product data submittals, without separate written request, or when acceptance will require revision to the Contract Documents. D. Substitution Submittal Procedure: j 1. Submit three copies of request for substitution for consideration. Limit each request to one proposed substitution. �r 2. Submit shop drawings, product data, and certified test results attesting to the proposed product equivalence. Burden of proof is on proposer. 3. The Design Learned, Inc. will notify Contractor in writing of decision to accept or reject t„ request. 3.02 TRANSPORTATION AND HANDLING A. Coordinate schedule of product delivery to designated prepared areas in order to minimize site storage time and potential damage to stored materials. r,+ B. Transport and handle products in accordance with manufacturer's instructions. {it C. Transport materials in covered trucks to prevent contamination of product and littering of 1. surrounding areas. D. Promptly inspect shipments to ensure that products comply with requirements, quantities are correct, and products are undamaged. r� E. Provide equipment and personnel to handle products by methods to prevent soiling, disfigurement, or damage. F. Arrange for the return of packing materials, such as wood pallets,where economically feasible. 3.03 STORAGE AND PROTECTION A. Designate receiving/storage areas for incoming products so that they are delivered according to installation schedule and placed convenient to work area in order to minimize waste due to excessive materials handling and misapplication. ` I Fishers Island Community Center 01600 -2 10/20/2006 PRODUCT REQUIREMENTS /� 1I B. Store and protect products in accordance with manufacturers'instructions. C. Store with seals and labels intact and legible. i D. Store sensitive products in weather tight, climate controlled, enclosures in an environment favorable to product. E. For exterior storage of fabricated products, place on sloped supports above ground. F. Cover products subject to deterioration with impervious sheet covering. Provide ventilation to prevent condensation and degradation of products. r, G. Prevent contact with material that may cause corrosion, discoloration, or staining. H. Provide equipment and personnel to store products by methods to prevent soiling, ;4_ disfigurement, or damage. I. Arrange storage of products to permit access for inspection. Periodically inspect to verify products are undamaged and are maintained in acceptable condition. r 1 END OF SECTION I �+ C 1 �1 i� �r Fishers Island Community Center 01600 -3 10/20/2006 PRODUCT REQUIREMENTS SECTION 13851 FIRE ALARM SYSTEM PART1 GENERAL 1.01 SECTION INCLUDES A. Fire alarm duct smoke detectors for HVAC. 1.02 REFERENCES A. IEEE C62.41 - IEEE Recommended Practice on Surge Voltages in Low-Voltage Power Circuits. B. NFPA 70- National Electrical Code. r< <„ C. NFPA 72-National Fire Alarm Code. D. NFPA 101 -Code for Safety to Life from Fire in Buildings and Structures. 1.03 SUBMITTALS A. See Section 01300 -Administrative Requirements,for submittal procedures. 44r',l B. Evidence of installer qualifications. C. Inspection and Test Reports: 1. Submit inspection and test plan prior to closeout demonstration. 2. Submit documentation of satisfactory inspections and tests. 3. Submit NFPA 72 Inspection and Test Form, filled out. D. Operating and Maintenance Data: Revise and resubmit until acceptable; have one set available during closeout demonstration: 1. Complete set of specified design documents, as approved by authority having jurisdiction. 2. Additional printed set of project record documents and closeout documents, bound or filed in same manuals. 3. Contact information for firm that will be providing contract maintenance and trouble call-back service. 4. List of recommended spare parts, tools, and instruments for testing. 5. Replacement parts list with current prices, and source of supply. 6. Detailed troubleshooting guide and large scale input/output matrix. 7. Detailed but easy to read explanation of procedures to be taken by non-technical administrative personnel in the event of system trouble, when routine testing is being conducted,for fire drills, and when entering into contracts for remodeling. E. Project Record Documents: Have one set available during closeout demonstration: 1. Complete set of floor plans showing actual installed locations of components, conduit, and zones. 1 2. "As installed"wiring and schematic diagrams, with final terminal identifications. f' 3. "As programmed"operating sequences, including control events by device, updated - input/output chart, and voice messages by event. F. Closeout Documents: 1. Certification by manufacturer that the system has been installed in compliance with his installation requirements, is complete, and is in satisfactory operating condition. 2. NFPA 72"Record of Completion",filled out completely and signed by installer and authorized representative of authority having jurisdiction. 1.04 QUALITY ASSURANCE A. Installer Qualifications: Firm with minimum 3 years documented experience installing fire alarm Fishers Island Community Center 13851 - 1 10/20/2006 FIRE ALARM SYSTEM systems of the specified type and providing contract maintenance service as a regular part of their business. 1. Installer Personnel: At least 2 years of experience installing fire alarm systems. j 2. Supervisor: NICET level III or IV(3 or 4)certified fire alarm technician; furnish name and address. 3. Certified in Fishers Island, NY as fire alarm installer. s 1.05 WARRANTY A. Provide control panel manufacturer's warranty that system components other than wire and L- conduit are free from defects and will remain so for 1 year after date of Substantial Completion. B. Provide installer's warranty that the installation is free from defects and will remain so for 1 year after date of Substantial Completion. i ; PART2 PRODUCTS -- 2.01 FIRE ALARM SYSTEM A. Fire Alarm System: Provide a new automatic fire detection and alarm system: 1. Provide all components necessary, regardless of whether shown in the contract documents or not. 2. Protected Premises: Entire building shown on drawings. 3. Comply with the following; where requirements conflict, order of precedence of requirements is as listed: ; a. The Americans With Disabilities Act (ADA). b. The requirements of the State Fire Marshall. c. The requirements of the local authority having jurisdiction. d. Applicable local codes. e. The contract documents(drawings and specifications). f. NFPA 101. g. NFPA 72; where the word"should"is used consider that provision mandatory;where conflicts between requirements require deviation from NFPA 72, identify deviations clearly on design documents. 2.02 FIRE SAFETY SYSTEMS INTERFACES A. Alarm: Provide alarm initiation in accordance with NFPA 72 for the following: 1. Kitchen hood suppression activation; also disconnect fuel source from cooking equipment. 2. Elevator lobby, elevator hoistway,and elevator machine room smoke detectors. 3. Duct smoke detectors. B. Elevators: 1. Elevator lobby, hoistway,and machine room smoke detectors: Elevator recall for fire fighters' service. 2. Elevator Machine Room Heat Detector: Shut down elevator power prior to hoistway sprinkler activation. 1 C. HVAC: - 1. Duct Smoke Detectors: Close dampers indicated;shut down air handlers indicated. 2.03 COMPONENTS ; A. General: 1. Provide flush mounted units where installed in finish areas; in unfinished areas, surface mounted unit are acceptable. 2. Provide legible, permanent labels for each control device, using identification used in operation and maintenance data. Fishers Island Community Center 13851 -2 10/20/2006 FIRE ALARM SYSTEM ,i I t B. Fire Alarm Control Units, Initiating Devices, and Notification Appliances: ; listed by Underwriters Laboratories as suitable for the purpose intended. C. Surge Protection: Provide surge protection to power supplies of Fire Alarm system. PART 3 EXECUTION 3.01 INSTALLATION A. Install in accordance with applicable codes, NFPA 72, NFPA 70, and the contract documents. B. Conceal all wiring, conduit, boxes, and supports where installed in finished areas. C. Obtain Town of Southold's approval of locations of devices, before installation. D. Install instruction cards and labels. 3.02 INSPECTION AND TESTING FOR COMPLETION A. Notify Town of Southold and Design Learned 7 days prior to beginning completion inspections and tests. B. Notify authorities having jurisdiction and comply with their requirements for scheduling inspections and tests and for observation by their personnel. C. Provide the services of the installer's supervisor or person with equivalent qualifications to supervise inspection and testing, correction, and adjustments. D. Prepare for testing by ensuring that all work is complete and correct; perform preliminary tests as required. E. Provide all tools, software, and supplies required to accomplish inspection and testing. �i - F. Perform inspection and testing in accordance with NFPA 72 and requirements of local authorities; document each inspection and test. n G. Correct defective work, adjust for proper operation, and retest until entire system complies with contract documents. 3.03 Town of Southold PERSONNEL INSTRUCTION A. Provide the following instruction to designated Town of Southold personnel: 1. Hands-On Instruction: On-site, using operational system. 2. Classroom Instruction: Town of Southold furnished classroom, on-site or at other local 1) facility. B. Administrative: One-hour session(s)covering issues necessary for non-technical administrative staff; classroom: 1. Initial Training: 1 session pre-closeout. C. Basic Operation: One-hour sessions for attendant personnel,security officers, and engineering staff; combination of classroom and hands-on: 1. Initial Training: 1 session pre-closeout. 3.04 CLOSEOUT A. Closeout Demonstration: Demonstrate proper operation of all functions to Town of Southold. 1. Be prepared to conduct any of the required tests. `+ 2. Have at least one copy of operation and maintenance data, preliminary copy of project J' record drawings, input/output matrix, and operator instruction chart(s) available during demonstration. 3. Have authorized technical representative of control unit manufacturer present during demonstration. Fishers Island Community Center 13851 -3 10/20/2006 FIRE ALARM SYSTEM 4. Demonstration may be combined with inspection and testing required by authority having jurisdiction; notify authority having jurisdiction in time to schedule demonstration. 5. Repeat demonstration until successful. END OF SECTION 1. Ir �; f I, r� Fishers Island Community Center 13851 -4 10/20/2006 FIRE ALARM SYSTEM SECTION 15072 1 VIBRATION ISOLATION PART1 GENERAL 1.01 SECTION INCLUDES A. Vibration isolators. PART2 PRODUCTS 2.01 VIBRATION ISOLATORS A. Open Spring Isolators: 1. Springs: Minimum horizontal stiffness equal to 75 percent vertical stiffness, with working 7 deflection between 0.3 and 0.6 of maximum deflection. Color code springs for load carrying capacity. 2. Spring Mounts: Provide with leveling devices, minimum 0.25 inch thick neoprene sound pads, and zinc chromate plated hardware. 3. Sound Pads: Size for minimum deflection of 0.05 inch; meet requirements for neoprene pad isolators. } B. Restrained Open Spring Isolators: _ 1. Springs: Minimum horizontal stiffness equal to 75 percent vertical stiffness,with working deflection between 0.3 and 0.6 of maximum deflection. Color code springs for load carrying r , capacity. 2. Spring Mounts: Provide with leveling devices, minimum 0.25 inch thick neoprene sound pads,and zinc chromate plated hardware. 3. Sound Pads: Size for minimum deflection of 0.05 inch; meet requirements for neoprene pad isolators. 4. Restraint: Provide heavy mounting frame and limit stops. C. Closed Spring Isolators: 1. Type: Closed spring mount with top and bottom housing separated with neoprene rubber stabilizers. 2. Springs: Minimum horizontal stiffness equal to 75 percent vertical stiffness, with working deflection between 0.3 and 0.6 of maximum deflection. Color code springs for load carrying capacity. 3. Housings: Incorporate neoprene isolation pad meeting requirements for neoprene pad isolators, and neoprene side stabilizers with minimum 0.25 inch clearance. D. Restrained Closed Spring Isolators: 1. Type: Closed spring mount with top and bottom housing separated with neoprene rubber stabilizers. 2. Springs: Minimum horizontal stiffness equal to 75 percent vertical stiffness,with working deflection between 0.3 and 0.6 of maximum deflection. Color code springs for load carrying capacity. 3. Housings: Incorporate neoprene isolation pad meeting requirements for neoprene pad isolators, and neoprene side stabilizers with minimum 0.25 inch clearance and limit stops. ' E. Spring Hanger: 1. Springs: Minimum horizontal stiffness equal to 75 percent vertical stiffness, with working deflection between 0.3 and 0.6 of maximum deflection. Color code springs for load carrying capacity. 2. Housings: Incorporate neoprene isolation pad meeting requirements for neoprene pad isolators. 3. Misalignment: Capable of 20 degree hanger rod misalignment. Fishers Island Community Center 15072- 1 10/20/2006 VIBRATION ISOLATION F. Neoprene Pad Isolators: 1. Rubber or neoprene waffle pads. 2. Configuration: Single layer. PART 3 EXECUTION 3.01 INSTALLATION / A. Install in accordance with manufacturer's instructions. ,r'` END OF SECTION �I r i I Fishers Island Community Center 15072-2 10/20/2006 VIBRATION ISOLATION SECTION 15075 i 1 MECHANICAL IDENTIFICATION PART1 GENERAL 1.01 SECTION INCLUDES -' A. Nameplates. �? B. Tags. _- C. Pipe Markers. 1.02 REFERENCES A. ASME A13.1 -Scheme for the Identification of Piping Systems; The American Society of Mechanical Engineers. PART2 PRODUCTS 2.01 NAMEPLATES A. Description: Laminated three-layer plastic with engraved letters. �) 4 1. Letter Color: White. 2. Letter Height: 1/4 inch. 3. Background Color: Black. 2.02 TAGS A. Plastic Tags: Laminated three-layer plastic with engraved black letters on light contrasting background color. Tag size minimum 1-1/2 inch diameter. B. Metal Tags: Brass with stamped letters; tag size minimum 1-1/2 inch diameter with smooth edges. 2.03 PIPE MARKERS A. Color: Conform to ASME A13.1. B. Plastic Pipe Markers: Factory fabricated,flexible, semi-rigid plastic, preformed to fit around pipe or pipe covering; minimum information indicating flow direction arrow and identification of fluid being conveyed. C. Plastic Tape Pipe Markers: Flexible, vinyl film tape with pressure sensitive adhesive backing and printed markings. PART 3 EXECUTION 3.01 PREPARATION l; A. Degrease and clean surfaces to receive adhesive for identification materials. -' 3.02 INSTALLATION A. Install plastic nameplates with corrosive-resistant mechanical fasteners, or adhesive. Apply with sufficient adhesive to ensure permanent adhesion and seal with clear lacquer. B. Install tags with corrosion resistant chain. C. Install plastic pipe markers in accordance with manufacturer's instructions. D. Install plastic tape pipe markers complete around pipe in accordance with manufacturer's instructions. 11 l� Fishers Island Community Center 15075 - 1 10/20/2006 MECHANICAL IDENTIFICATION E. Identify air handling units, pumps, heat transfer equipment, tanks, and water treatment devices with plastic nameplates. Small devices,such as in-line pumps, may be identified with tags. F. Identify control panels and major control components outside panels with plastic nameplates. G. Identify thermostats relating to terminal boxes or valves with nameplates. H. Identify valves in main and branch piping with tags. I. Identify piping, concealed or exposed,with plastic pipe markers. Use tags on piping 3/4 inch diameter and smaller. Identify service, flow direction,and pressure. Install in clear view and align with axis of piping. Locate identification not to exceed 20 feet on straight runs including risers and drops, adjacent to each valve and Tee, at each side of penetration of structure or - enclosure, and at each obstruction. J. Identify ductwork with plastic nameplates. Identify with air handling unit identification number and area served. Locate identification at air handling unit, at each side of penetration of structure or enclosure, and at each obstruction. END OF SECTION c, i it r' Fishers Island Community Center 15075-2 10/20/2006 MECHANICAL IDENTIFICATION S SECTION 15076 PIPING AND VALVE IDENTIFICATION PART1 GENERAL 1.01 SECTION INCLUDES A. Pipe Markers. i, B. Stencils. C. Valve Tags. u� 1.02 REFERENCES A. ASME A13.1 -Scheme for the Identification of Piping Systems;The American Society of Mechanical Engineers(ANSI/ASME A13.1). 1.03 SYSTEM DESCRIPTION A. Color Coding and Nomenclature for Building Piping: Conform to ASME A13.1. 1.04 SUBMITTALS A. See Section 01300 -Administrative Requirements,for submittal procedures. B. Pipe Schedule: Schedule of wording,symbols, letter size, and color coding for piping r identification. C. Valve Schedule: Schedule of wording,symbols, letter size, and color coding for valve identification. PART2 PRODUCTS 2.01 MANUFACTURERS A. Acceptable Manufacturer: Seton Identification Products; 20 Thompson Road, Branford CT 06405-2842;Telephone 203-488-8059, FAX 203-488-5973;Toll Free Telephone 800-243-6624, Toll Free FAX 800-345-7819. Email: Custsvc_SetonUS@seton.com.www.seton.com B. Substitutions: See Section 01600-Product Requirements. 2.02 MANUFACTURED UNITS A. Pipe Markers for Indoor Use: Seton Seton-Code; media indicator on pressure-sensitive vinyl sheet,with detachable direct-of-flow arrows. B. Pipe Markers for Outdoor Use: Seton Weather-Code; media indicator and detachable r direction-of-flow arrows on weather-resistant pressure-sensitive vinyl sheet; service temperature -40 to 175 degrees F. C. Direction-Of-Flow Arrows: Seton Arrows-On-A-Roll; direction-of-flow arrows on pressure-sensitive vinyl tape roll. D. Pipe Stencils: Factory-cut stencils with media indicator and direction-of-flow arrows. i E. Valve Tags: Plastic; Media and identification number imprinted on tag. F. Valve Tag Securing Devices: Number 6 brass bead chain; provide one securing device for each tag in accepted schedule. PART 3 EXECUTION f� 3.01 INSTALLATION Fishers Island Community Center 15076 - 1 10/20/2006 PIPING AND VALVE IDENTIFICATION A. Install pipe markers in accordance with accepted shop drawings and manufacturer's instructions. B. Install valve tags in accordance with accepted shop drawings and manufacturer's instructions. END OF SECTION 4 ' � I �r 1 V t' it Fishers Island Community Center 15076-2 10/20/2006 PIPING AND VALVE IDENTIFICATION 1 I SECTION 15082 PIPING INSULATION PART1 GENERAL 1.01 SECTION INCLUDES A. Piping insulation. 1.02 RELATED SECTIONS 4 A. Section 07840- Firestopping. r-=- B. Section 15145-Plumbing Piping: Placement of hangers and hanger inserts. y C. Section 15182- Hydronic Piping: Placement of hangers and hanger inserts. D. Section 15186- Refrigerant Piping and Specialties: Placement of inserts. L 1.03 REFERENCES A. ASTM C 534-Standard Specification for Preformed Flexible Elastomeric Cellular Thermal Insulation in Sheet and Tubular Form. ' B. ASTM E 84-Standard Test Method for Surface Burning Characteristics of Building Materials. =� C. ASTM E 96-Standard Test Methods for Water Vapor Transmission of Materials. a D. NFPA 255-Standard Method of Test of Surface Burning Characteristics of Building Materials; National Fire Protection Association. E. UL 723-Standard for Test for Surface Burning Characteristics of Building Materials; Underwriters Laboratories Inc.. 1.04 SUBMITTALS ` A. See Section 01300 -Administrative Requirements,for submittal procedures. r B. Product Data: Provide product description,thermal characteristics, list of materials and thickness for each service, and locations. PART 2 PRODUCTS-ARMAFLEXAS SPECIFIED 2.01 REQUIREMENTS FOR ALL PRODUCTS OF THIS SECTION A. Surface Burning Characteristics: Flame spread/Smoke developed index of 25/50, maximum, when tested in accordance with ASTM E 84, NFPA 255, or UL 723. 2.02 FLEXIBLE ELASTOMERIC CELLULAR INSULATION A. Insulation: Preformed flexible elastomeric cellular rubber insulation complying with ASTM C 534 Grade 3; use molded tubular material wherever possible. 1. Minimum Service Temperature: -40 degrees F. 2. Maximum Service Temperature: 220 degrees F. 3. Connection: Waterproof vapor barrier adhesive. 2.03 JACKETS A. PVC Plastic. 1. Jacket: One piece molded type fitting covers and sheet material, off-white color. a. Minimum Service Temperature: 0 degrees F. b. Maximum Service Temperature: 150 degrees F. c. Moisture Vapor Permeability: 0.002 perm inch, maximum,when tested in accordance Fishers Island Community Center 15082- 1 10/20/2006 PIPING INSULATION `\ I with ASTM E 96. d. Thickness: 10 mil. e. Connections: Brush on welding adhesive. l B. ABS Plastic: 1. Jacket: One piece molded type fitting covers and sheet material, off-white color. _ a. Minimum Service Temperature: -40 degrees F. b. Maximum Service Temperature of 180 degrees F. c. Moisture Vapor Permeability: 0.012 perm inch,when tested in accordance with ASTM E 96. d. Thickness: 30 mil. e. Connections: Brush on welding adhesive. C. Canvas Jacket: UL listed 6 oz/sq yd plain weave cotton fabric treated with dilute fire retardant lagging adhesive. PART 3 EXECUTION 3.01 EXAMINATION A. Verify that piping has been tested before applying insulation materials. B. Verify that surfaces are clean and dry, with foreign material removed. 3.02 INSTALLATION A. Install in accordance with manufacturer's instructions. B. All hot and cold potable water piping without exception is to be insulated with Armaflex. Tape and seal all seams and joints. C. Exposed Piping: Locate insulation and cover seams in least visible locations. `- D. Insulated pipes conveying fluids below ambient temperature: Insulate entire system including fittings, valves, unions, flanges,strainers,flexible connections, pump bodies, and expansion joints. E. For hot piping conveying fluids 140 degrees F or less, do not insulate flanges and unions at equipment, but bevel and seal ends of insulation. F. Continue insulation through walls, sleeves, pipe hangers, and other pipe penetrations. Finish at supports, protrusions, and interruptions. At fire separations, refer to Section 07840. w G. Pipe Exposed in Mechanical Equipment Rooms or Finished Spaces (less than 10 feet above ti finished floor): Finish with canvas jacket sized for finish painting. END OF SECTION Fishers Island Community Center 15082 -2 10/20/2006 PIPING INSULATION (I i SECTION 15086 DUCT INSULATION PART1 GENERAL 1.01 SECTION INCLUDES A. Duct Liner. B. Insulation jackets. 1.02 REFERENCES A. ASTM C 518-Standard Test Method for Steady-State Thermal Transmission Properties by ` Means of the Heat Flow Meter Apparatus. B. ASTM C 553-Specification for Mineral Fiber Blanket Thermal Insulation for Commercial and I Industrial Applications. C. ASTM C 612-Standard Specification for Mineral Fiber Block and Board Thermal Insulation. D. ASTM C 1011 -Standard Specification for Fibrous Glass Duct Lining Insulation(Thermal and Sound Absorbing Material). E. ASTM E 84-Standard Test Method for Surface Burning Characteristics of Building Materials. ~ F. ASTM E 96-Standard Test Methods for Water Vapor Transmission of Materials. fi r G. SMACNA(DCS)-HVAC Duct Construction Standards- Metal and Flexible; Sheet Metal and Air -, Conditioning Contractors'National Association. 1.03 SUBMITTALS A. See Section 01300 -Administrative Requirements,for submittal procedures. � PART2 PRODUCTS 2.01 REQUIREMENTS FOR ALL PRODUCTS OF THIS SECTION A. Surface Burning Characteristics: Flame spread/Smoke developed index of 25/50, maximum, when tested in accordance with ASTM E 84, NFPA 255, or UL 723. 2.02 GLASS FIBER, FLEXIBLE �L J A. Insulation: ASTM C 553; flexible, noncombustible blanket. 1. W value: 0.36 at 75 degrees F,when tested in accordance with ASTM C 518. 2. Maximum Service Temperature: 450 degrees F. 3. Maximum Water Vapor Sorption: 5.0 percent by weight. �r B. Vapor Barrier Jacket: 1. Kraft paper with glass fiber yarn and bonded to aluminized film. 2. Moisture Vapor Permeability: 0.02 perm inch,when tested in accordance with ASTM E 96. 3. Secure with pressure sensitive tape. 2.03 GLASS FIBER, RIGID A. Insulation: ASTM C 612; rigid, noncombustible blanket. 1. W value: 0.24 at 75 degrees F, when tested in accordance with ASTM C 518. 2. Maximum service temperature: 450 degrees F. - 3. Maximum Water Vapor Sorption: 5.0 percent. 4. Maximum Density: 8.0 Ib/cu ft. B. Vapor Barrier Jacket: Fishers Island Community Center 15086 - 1 10/20/2006 DUCT INSULATION 1. Kraft paper with glass fiber yarn and bonded to aluminized film. 2. Moisture Vapor Permeability: 0.02 perm inch,when tested in accordance with ASTM E 96. 3. Secure with pressure sensitive tape. 2.04 JACKETS A. Canvas Jacket: UL listed 6 oz/sq yd plain weave cotton fabric treated with dilute fire retardant lagging adhesive. , 2.05 DUCT LINER A. Insulation: Incombustible glass fiber complying with ASTM C 1071;flexible blanket, rigid board, and preformed round liner board; impregnated surface and edges coated with poly vinyl acetate polymer,or acrylic polymer shown to be fungus and bacteria resistant by testing to ASTM G 21. 1. Apparent Thermal Conductivity: Maximum of 0.31 at 75 degrees F. 2. Service Temperature: Up to 250 degrees F. 3. Rated Velocity on Coated Air Side for Air Erosion: 5,000 fpm, minimum. B. Liner Fasteners: Galvanized steel, self-adhesive pad with integral head. !° PART 3 EXECUTION 3.01 EXAMINATION A. Verify that ducts have been tested before applying insulation materials. B. Verify that surfaces are clean,foreign material removed, and dry. 3.02 INSTALLATION �'= A. Install in accordance with manufacturer's instructions. B. External Duct Insulation Application: t' 1. Secure insulation with vapor barrier with wires and seal jacket joints with vapor barrier adhesive or tape to match jacket. 2. Secure insulation without vapor barrier with staples, tape, or wires. " 3. Install without sag on underside of duct. Use adhesive or mechanical fasteners where necessary to prevent sagging. Lift duct off trapeze hangers and insert spacers. 4 4. Seal vapor barrier penetrations by mechanical fasteners with vapor barrier adhesive. i 5. Stop and point insulation around access doors and damper operators to allow operation without disturbing wrapping. C. Duct Liner Application: 1. Adhere insulation with adhesive for 100 percent coverage. 2. Secure insulation with mechanical liner fasteners. Refer to SMACNA HVAC Duct Construction Standards- Metal and Flexible for spacing. 3. Seal and smooth joints. Seal and coat transverse joints. 4. Seal liner surface penetrations with adhesive. 5. Duct dimensions indicated are net inside dimensions required for air flow. Increase duct size to allow for insulation thickness. END OF SECTION Fishers Island Community Center 15086 -2 10/20/2006 DUCT INSULATION SECTION 15145 PLUMBING PIPING PART1 GENERAL j, 1.01 SECTION INCLUDES A. Pipe, pipe fittings, valves, and connections for piping systems. 1. Sanitary sewer. 1 2. Domestic water. 3. Gas. 1.02 REFERENCES �l A. ASME B16.3 - Malleable Iron Threaded Fittings;The American Society of Mechanical Engineers. B. ASME B31.2 - Fuel Gas Piping;The American Society of Mechanical Engineers. j C. ASTM A 53/A 53M-Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, ` - Welded and Seamless. D. ASTM A 234/A 234M-Standard Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Moderate and High Temperature Service. E. ASTM D 2239-Standard Specification for Polyethylene(PE) Plastic Pipe (SIDR-PR)Based on Controlled Inside Diameter. F. ASTM D 2447-Standard Specification for Polyethylene(PE) Plastic Pipe, Schedules 40 and 80, Based on Outside Diameter. G. ASTM D 2609-Standard Specification for Plastic Insert Fittings for Polyethylene(PE) Plastic Pipe. H. MSS SP-78-Cast Iron Plug Valves, Flanged and Threaded Ends; Manufacturers Standardization Society of the Valve and Fittings Industry, Inc.. I. NFPA 58-Liquefied Petroleum Gas Code; National Fire Protection Association. 1.03 SUBMITTALS A. See Section 01300 -Administrative Requirements,for submittal procedures. ` B. Product Data: Provide data on pipe materials, pipe fittings, valves, and accessories. Provide manufacturers catalog information. Indicate valve data and ratings. 1.04 QUALITY ASSURANCE A. Perform Work in accordance with State of New York, standards. i 1.05 REGULATORY REQUIREMENTS A. Conform to applicable code for installation of backflow prevention devices. B. Provide certificate of compliance from authority having jurisdiction indicating approval of installation of backflow prevention devices. 1.06 DELIVERY,STORAGE,AND PROTECTION ? A. Provide temporary end caps and closures on piping and fittings. Maintain in place until installation. B. Protect piping systems from entry of foreign materials by temporary covers, completing sections ` of the work, and isolating parts of completed system. Fishers Island Community Center 15145 - 1 10/20/2006 PLUMBING PIPING PART2 PRODUCTS 2.01 WATER PIPING, BURIED WITHIN 5 FEET OF BUILDING A. Copper Pipe: ASTM B 42, hard drawn. 1. Fittings: ASME B16.18,cast copper alloy or ASME B16.22 wrought copper and bronze. 2. Joints: ASTM B 32, alloy Sn95 solder. r B. PE Pipe: ASTM D 2239, or ASTM D 2447 Schedule 40. 1. Fittings: ASTM D 2609, PE. 2. Joints: Mechanical with stainless steel clamp. C. Polyethylene/Aluminum Composite Pipe: ASTM F 1281 or ASTM F 1282. 1. Fittings and Joints: Brass compression type. r 2.02 WATER PIPING,ABOVE GRADE A. Copper Tube: ASTM B 88 (ASTM B 88M), Type L(B), Drawn (H). 1. Fittings: ASME B16.18,cast copper alloy or ASME B16.22,wrought copper and bronze. 2. Joints: ASTM B 32, alloy Sn95 solder. 2.03 PROPANE GAS PIPING, BURIED BEYOND 5 FEET OF BUILDING A. Steel Pipe: ASTM A 53/A 53M Schedule 40 black. 1. Fittings: ASTM A 234/A 234M, wrought steel welding type,with AWWA C105/A21.5 polyethylene jacket or double layer, half-lapped 10 mil polyethylene tape. 2. Joints: ASME B31.1, welded. 2.04 PROPANE GAS PIPING, BURIED WITHIN 5 FEET OF BUILDING r- 2.05 PROPANE GAS PIPING,ABOVE GRADE a i A. Steel Pipe: ASTM A 53/A 53M Schedule 40 black. 1. Fittings: ASME B16.3, malleable iron, or ASTM A 234/A 234M, wrought steel welding type. 2. Joints: NFPA 58, threaded or welded to ASME B31.1. 2.06 FLANGES,UNIONS,AND COUPLINGS A. Unions for Pipe Sizes 3 inches and Under: Provide for all serviceable equipment y"1 1. Ferrous pipe: Class 150 malleable iron threaded unions. 2. Copper tube and pipe: Class 150 bronze unions with soldered joints. B. Dielectric Connections: Union with galvanized or plated steel threaded end, copper solder end, water impervious isolation barrier. 2.07 PIPE HANGERS AND SUPPORTS - A. Plumbing Piping -Water: 1. Conform to ASME B31.9. 2. Hangers for Pipe Sizes 1/2 Inch to 1-1/2 Inches: Malleable iron, adjustable swivel, split ring. 3. Hangers for Cold Pipe Sizes 2 Inches and Over: Carbon steel, adjustable, clevis. 4. Hangers for Hot Pipe Sizes 2 Inches to 4 Inches: Carbon steel, adjustable,clevis. 2.08 GATE VALVES A. Manufacturers: Submit for approval.. 2.09 BALL VALVES A. Manufacturers:Submit for approval. 2.10 PLUG VALVES Fishers Island Community Center 15145 -2 10/20/2006 PLUMBING PIPING I I A. Construction 2-1/2 Inches and Larger: MSS SP-78, 175 psi CWP, cast iron body and plug, pressure lubricated, teflon or Buna N packing, flanged or grooved ends. Provide lever operator with set screw. PART 3 EXECUTION 3.01 EXAMINATION ' A. Verify that excavations are to required grade,dry,and not over-excavated. 1 � 3.02 PREPARATION A. Ream pipe and tube ends. Remove burrs. Bevel plain end ferrous pipe. B. Remove scale and dirt,on inside and outside, before assembly. . n C. Prepare piping connections to equipment with flanges or unions. 3.03 INSTALLATION A. Install in accordance with manufacturer's instructions. B. Provide non-conducting dielectric connections wherever jointing dissimilar metals. C. Route piping in orderly manner and maintain gradient. Route parallel and perpendicular to walls. D. Install piping to maintain headroom, conserve space, and not interfere with use of space. E. Group piping whenever practical at common elevations. F. Provide clearance in hangers and from structure and other equipment for installation of insulation and access to valves and fittings. Refer to Section 15082. G. Provide access where valves and fittings are not exposed. H. Establish elevations of buried piping outside the building to ensure not less than 4 ft of cover. I. Provide support for utility meters in accordance with requirements of utility companies. J. Prepare exposed, unfinished pipe, fittings, supports, and accessories ready for finish painting. K. Sleeve pipes passing through partitions,walls and floors. L. Inserts: 1. Provide inserts for placement in concrete formwork. 2. Provide inserts for suspending hangers from reinforced concrete slabs and sides of reinforced concrete beams. 3. Provide hooked rod to concrete reinforcement section for inserts carrying pipe over 4 inches. ? 4. Where concrete slabs form finished ceiling, locate inserts flush with slab surface. M. Pipe Hangers and Supports: 1. Install in accordance with ASME B31.9. _ 2. Support horizontal piping as scheduled. 3. Install hangers to provide minimum 1/2 inch space between finished covering and adjacent work. 4. Place hangers within 12 inches of each horizontal elbow. 5. Use hangers with 1-1/2 inch minimum vertical adjustment. Design hangers for pipe movement without disengagement of supported pipe. 6. Support vertical piping at every floor. Support riser piping independently of connected horizontal piping. 7. Where several pipes can be installed in parallel and at same elevation, provide multiple or } trapeze hangers. L--J ? Fishers Island Community Center 15145-3 10/20/2006 PLUMBING PIPING j 8. Prime coat and finish paint exposed steel hangers and supports. 3.04 APPLICATION A. Install unions downstream of valves and at equipment or apparatus connections. B. Install gate valves for shut-off and to isolate equipment, part of systems, or vertical risers. C. Provide plug valves in natural gas systems for shut-off service. 3.05 SCHEDULES A. Pipe Hanger Spacing: (j 1. Metal Piping: a. Pipe size: 1/2 inches to 1-1/4 inches: 1) Maximum hanger spacing: 6.5 ft. b. Pipe size: 1-1/2 inches to 2 inches: 1) Maximum hanger spacing: 10 ft. END OF SECTION ; i u ' ' i j Fishers Island Community Center 15145-4 10/20/2006 PLUMBING PIPING i 'J SECTION 15182 HYDRONIC PIPING � PART1 GENERAL 1.01 SECTION INCLUDES A. Pipe and pipe fittings for: 1. Heating water piping system. 2. Chilled water piping system. 3. Equipment drains and overflows. 1.02 REFERENCES A. ASME B16.3 -Malleable Iron Threaded Fittings;The American Society of Mechanical Engineers. B. ASTM A 53/A 53M-Standard Specification for Pipe, Steel, Black and Hot-Dipped,Zinc-Coated, I Welded and Seamless. C. ASTM A 234/A 234M-Standard Specification for Piping Fittings of Wrought Carbon Steel and Alloy Steel for Moderate and High Temperature Service. D. AWS D1.1/D1.1M -Structural Welding Code-Steel; American Welding Society. E. AWWA C105/A21.5- Polyethylene Encasement for Ductile-Iron Pipe Systems;American Water Works Association (ANSI/AWWA C105/A21.5). 1.03 SUBMITTALS A. See Section 01300-Administrative Requirements,for submittal procedures. _. 1.04 DELIVERY,STORAGE,AND HANDLING A. Protect piping systems from entry of foreign materials by temporary covers, completing sections of the work, and isolating parts of completed system. PART2 PRODUCTS 2.01 CHILLED WATER PIPING, BURIED A. Steel Pipe: ASTM A 53/A 53M,Schedule 40, black with AWWA C105/A21.5 polyethylene jacket, or double layer, half-lapped polyethylene tape. 1. Fittings: ASTM A 234/A 234M, wrought steel welding type with double layer, half-lapped polyethylene tape. 2. Joints: Welded in accordance with AWS D1.1. 3. Casing: Closed glass cell insulation. 2.02 CHILLED WATER PIPING,ABOVE GRADE A. Steel Pipe: ASTM A 53/A 53M,Schedule 40, black. 1. Fittings: ASME 616.3, malleable iron or ASTM A 234/A 234M, wrought steel welding type. 2. Joints: Threaded or AWS D1.1 welded. 1 2.03 PIPE HANGERS AND SUPPORTS A. Hangers for Pipe Sizes 1/2 to 1-1/2 Inch: Malleable iron, adjustable swivel, split ring. B. Hangers for Cold Pipe Sizes 2 Inches and Over: Carbon steel, adjustable,clevis. C. Multiple or Trapeze Hangers: Steel channels with welded spacers and hanger rods. D. Wall Support for Pipe Sizes to 3 Inches: Cast iron hook. Fishers Island Community Center 15182 - 1 10/20/2006 HYDRONIC PIPING E. Wall Support for Pipe Sizes 4 Inches and Over: Welded steel bracket and wrought steel clamp. F. Floor Support for Cold Pipe: Cast iron adjustable pipe saddle, lock nut, nipple, floor flange, and concrete pier or steel support. G. Hanger Rods: Mild steel threaded both ends,threaded one end, or continuous threaded. 2.04 UNIONS, FLANGES,AND COUPLINGS A. Unions for Pipe 2 Inches and Under: 1. Ferrous Piping: 150 psig malleable iron, threaded. B. Flanges for Pipe Over 2 Inches: 1. Ferrous Piping: 150 psig forged steel, slip-on. 2. Gaskets: 1/16 inch thick preformed neoprene. C. Grooved and Shouldered Pipe End Couplings: 1. Housing Clamps: Malleable iron galvanized to engage and lock, designed to permit some angular deflection, contraction, and expansion. r 'i 2. Sealing Gasket: C-shape elastomer composition for operating temperature range from -30 } degrees F to 230 degrees F. 2.05 GLOBE OR ANGLE VALVES G A. Up To and Including 2 Inches: 1. Bronze body, bronze trim, screwed bonnet, rising stem and handwheel, inside screw with backseating stem, renewable composition disc and bronze seat, solder ends. B. Over 2 Inches: 1. Iron body, bronze trim, bolted bonnet, rising stem, handwheel, outside screw and yoke, rotating plug-type disc with renewable seat ring and disc, flanged ends. 2.06 BALL VALVES A. Up To and Including 2 Inches: 1. Bronze one piece body, chrome plated brass ball, teflon seats and stuffing box ring, lever - handle with balancing stops, solder ends with union. B. Over 2 Inches: 1. Cast steel body,chrome plated steel ball, teflon seat and stuffing box seals, lever handle, flanged. _ END OF SECTION Fishers Island Community Center 15182 -2 10/20/2006 HYDRONIC PIPING r--i SECTION 15186 REFRIGERANT PIPING AND SPECIALTIES PART1 GENERAL 1.01 SECTION INCLUDES A. Piping. r 1.02 REFERENCES A. ASME B16.22 -Wrought Copper and Copper Alloy Solder Joint Pressure Fittings; The American Society of Mechanical Engineers. i ! B. ASME B31.5- Refrigeration Piping and Heat Transfer Components;The American Society of Mechanical Engineers. C. ASTM B 280-Standard Specification for Seamless Copper Tube for Air Conditioning and � Refrigeration Field Service.i . D. AWS A5.8/A5.8M-Specification for Filler Metals for Brazing and Braze Welding; American Welding Society. 1.03 SYSTEM DESCRIPTION - A. Where more than one piping system material is specified ensure system components are ' compatible and joined to ensure the integrity of the system is not jeopardized. Provide necessary joining fittings. Ensure flanges, union, and couplings for servicing are consistently r- provided. B. Provide pipe hangers and supports in accordance with ASME B31.5 unless indicated otherwise. C. Filter-Driers: 1. Use a filter-drier immediately ahead of liquid-line controls, such as thermostatic expansion i valves, solenoid valves, and moisture indicators. 1.04 SUBMITTALS A. See Section 01300-Administrative Requirements,for submittal procedures. B. Shop Drawings: Indicate schematic layout of system, including equipment, critical dimensions, and sizes. PART2 PRODUCTS 2.01 PIPING A. Copper Tube: ASTM B 280, H58 hard drawn or 060 soft annealed. 1. Fittings: ASME B16.22 wrought copper. 2. Joints: Braze,AWS A5.8 BCuP silver/phosphorus/copper alloy. B. Pipe Supports and Anchors: 1. Conform to ASME B31.5. 2. Hangers for Pipe Sizes 1/2 to 1-1/2 Inch: Malleable iron adjustable swivel, split ring. 3. Vertical Support: Steel riser clamp. 4. Copper Pipe Support: Carbon steel ring, adjustable,copper plated. PART 3 EXECUTION 3.01 INSTALLATION 7 A. Install refrigeration specialties in accordance with manufacturers instructions. S Fishers Island Community Center 15186 - 1 10/20/2006 REFRIGERANT PIPING AND SPECIALTIES B. Route piping in orderly manner,with plumbing parallel to building structure, and maintain gradient. C. Install piping to conserve building space and avoid interference with use of space. D. Install piping to allow for expansion and contraction without stressing pipe,joints, or connected equipment. E. Pipe Hangers and Supports: 1. Install in accordance with ASME B31.5. 2. Support horizontal piping as scheduled. „ 3. Install hangers to provide minimum 1/2 inch space between finished covering and adjacent work. 4. Place hangers within 12 inches of each horizontal elbow. 5. Support vertical piping at every other floor. Support riser piping independently of connected horizontal piping. 6. Provide copper plated hangers and supports for copper piping. 3.02 SCHEDULES � y A. Hanger Spacing for Copper Tubing. 1. 1/2 inch, 5/8 inch, and 7/8 inch OD: Maximum span, 5 feet; minimum rod size, 1/4 inch. END OF SECTION -4 'ram l f, I 1 l Fishers Island Community Center 15186 -2 10/20/2006 REFRIGERANT PIPING AND SPECIALTIES fr l r-� SECTION 15512 CAST-IRON BOILERS PART1 GENERAL 1.01 SECTION INCLUDES A. Boilers. r B. Controls and boiler trim. f C. Fuel connection. D. Collector, draft hood, and chimney connection. E. Circulator. F. Expansion tank. j � 1.02 REFERENCES A. ASME(BPV Vill, 1)-Boiler and Pressure Vessel Code, Section Vill, Division 1 - Rules for Construction of Pressure Vessels; The American Society of Mechanical Engineers. i , B. HI BTS-Testing and Rating Standard for Commercial Boilers;The Hydronics Institute. 1.03 PERFORMANCE REQUIREMENTS A. Performance rating shall be in accordance with Hydronics Institute Testing and Rating Standard for Commercial Boilers. 1.04 SUBMITTALS A. See Section 01300-Administrative Requirements,for submittal procedures. B. Product Data: Provide data indicating general layout, dimensions, and size and location of water, gas, and vent connections, and electrical characteristics and connection requirements: C. Operation and Maintenance Data: Include manufacturer's descriptive literature, operating instructions, cleaning procedures, replacement parts list, and maintenance and repair data. PART2 PRODUCTS I� 2.01 MANUFACTURERS i A. Burnham Boilers B. Substitutions: See Section 01600-Product Requirements. 2.02 MANUFACTURED UNITS A. Hot Water Boilers: Suitable for forced draft with insulated jacket, sectional cast iron heat exchanger, natural gas burning system, refractory, controls, and boiler trim including circulator L' and fill system consisting of diaphragm type expansion tank, fill and check valve, and automatic air vent. 2.03 FABRICATION A. Access: To flue passages for cleaning and flame observation ports. 2.04 HOT WATER BOILER TRIM A. ASME rated pressure relief valve, 30 psig. B. Combination water pressure and temperature gage. Fishers Island Community Center 15512- 1 10/20/2006 CAST-IRON BOILERS I I C. Low water cut-off to prevent burner operation when boiler waterfalls below safe level. D. High limit temperature controller with manual reset for burner to prevent boiler water temperature from exceeding safe system temperature. E. Boiler air vent. 2.05 FUEL BURNING SYSTEM A. Burner Operation: On-off with low fire position for ignition. B. Gas Burner: Atmospheric type for propane adjustable combustion air supply, pressure regulator, gas valves, manual shut-off, intermittent spark or glow coil ignition,flame sensing device, and automatic 100 percent shut-off. C. Gas Burner Safety Controls: Energize ignition, limit time for establishment of flame, prevent opening of gas valve until pilot flame is proven, stop gas flow on ignition failure, energize blower motor,and after air flow proven and slight delay, allow gas valve to open. D. Collector and Draft Hood: Non-metallic vent pipe. E. Controls: Pre-wired, factory assembled electronic controls in control cabinet with flame scanner or detector, programming control, relays, and switches. Provide pre-purge and post-purge ignition and shut-down of burner in event of ignition pilot and main flame failure with manual reset. 2.06 CIRCULATOR A. Type: Horizontal shaft, single stage, direct connected,with resiliently mounted motor for in line mounting, oil lubricated, for 125 psig maximum working pressure. 1. Casing: Cast iron. 2. Impeller: Cadmium plated steel, keyed to shaft. 3. Bearings: Two, oil lubricated bronze sleeves. i 4. Shaft: Alloy steel with copper sleeve, integral thrust collar. 5. Seal: Carbon rotating against a stationary ceramic seat, 225 degrees F maximum continuous operating temperature. 6. Drive: Flexible coupling. B. Performance: 1. Flow capacity: 10 gpm. 2. Head: 23 feet. C. Electrical Characteristics: 120 volt/1-phase/60 Hz. 2.07 DIAPHRAGM TYPE EXPANSION TANK A. Construction: Welded steel, tested and stamped in accordance with ASME(BPV VIII, 1); rated for working pressure of 125 psig,with flexible diaphragm sealed into tank, and steel legs or saddles. B. Accessories: Pressure gage and air-charging fitting, tank drain; precharge to 12 psi. ' I PART 3 EXECUTION - 3.01 INSTALLATION A. Install in accordance with manufacturer's instructions. 3.02 MANUFACTURER'S FIELD SERVICES A. Instruct operating personnel in operation and maintenance of units. END OF SECTION II Fishers Island Community Center 15512 -2 10/20/2006 CAST-IRON BOILERS L i SECTION 15620 PACKAGEDWATER CHILLERS PART1 GENERAL 1.01 SECTION INCLUDES A. Chiller package. l B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Condenser water connections. F. Refrigerant connections. G. Starters. 1.02 RELATED SECTIONS A. Section 15072 -Vibration Isolation. B. Section 15182- Hydronic Piping. r - C. Section 16155 -Equipment Wiring: Electrical characteristics and wiring connections. 1.03 REFERENCES i A. ARI 550/590 -Standard for Water Chilling Packages Using the Vapor Compression Cycle; Air-Conditioning and Refrigeration Institute. B. ASHRAE Std 15-Safety Standard for Refrigeration Systems;American Society of Heating, j Refrigerating and Air-Conditioning Engineers, Inc.. C. ASME(BPV)-Boiler and Pressure Vessel Code;The American Society of Mechanical Engineers. 11 D. ASME(BPV VIII, 1)-Boiler and Pressure Vessel Code, Section VIII, Division 1 - Rules for Construction of Pressure Vessels; The American Society of Mechanical Engineers. 1.04 SUBMITTALS A. See Section 01300 -Administrative Requirements,for submittal procedures. B. Product Data: Provide rated capacities,weights,specialties and accessories, electrical i ' requirements and wiring diagrams. C. Shop Drawings: Indicate components, assembly, dimensions, weights and loadings, required clearances, and location and size of field connections. Indicate valves, strainers, and thermostatic valves required for complete system. D. Manufacturer's Instructions: Submit manufacturer's complete installation instructions. E. Manufacturer's Certificate: Certify that components of package not furnished by manufacturer have been selected in accordance with manufacturer's requirements. i F. Operation and Maintenance Data: Include start-up instructions, maintenance data, parts lists, controls, and accessories. Include trouble-shooting guide. G. Warranty: Submit manufacturer's warranty and ensure forms have been filled out in Town of Southold's name and registered with manufacturer. Fishers Island Community Center 15620 - 1 10/20/2006 PACKAGED WATER CHILLERS J , I 1.05 DELIVERY,STORAGE,AND PROTECTION A. Comply with manufacturer's installation instructions for rigging, unloading,and transporting units. 1.06 WARRANTY A. See Section 01780 -Closeout Submittals, for additional warranty requirements. B. Provide a five year warranty to include coverage for compressor including materials only. PART 2 PRODUCTS 2.01 MANUFACTURED UNITS �I A. Provide factory assembled and tested water cooled liquid chillers consisting of compressors, condensers, evaporator,thermal expansion valve, refrigeration accessories, and control panel. Construction and ratings shall be in accordance with ARI 550/590. B. Conform to ASME(BPV VIII, 1) Boiler and Pressure Vessel Code for construction and testing of reciprocating water chillers. , b C. Conform to ASHRAE Std 15 for construction and operation of reciprocating water chillers. J 2.02 EVAPORATOR A. Provide evaporator of shell and tube type, seamless or welded steel construction with cast iron or fabricated steel heads, seamless copper tubes or red brass tubes with integral fins, rolled or silver brazed into tube sheets. Provide multiple refrigerant circuits on multiple compressor units. B. Design, test, and stamp refrigerant side for 225 psig working pressure and water side for 150 psig working pressure, in accordance with ASME(BPV VIII, 1). C. Insulate with 0.75 inch minimum thick flexible expanded polyvinyl chloride insulation with , maximum K value of 0.28. D. Provide water drain connection and thermometer wells for temperature controller and low temperature cutout. 2.03 CONDENSERS A. Provide condensers of shell and tube type, seamless or welded steel construction with cast iron 4 or fabricated steel heads, seamless copper tubes or red brass tubes with integral fins, rolled or silver brazed into tube sheets. `i B. Design, test, and stamp refrigerant side for 450 psig working pressure in accordance with ASME (BPV VIII, 1). C. Provide integral subcooler circuit. D. Provide 450 psig safety relief valve on condenser shell. E. Design, test, and stamp water side for 150 psig working pressure in accordance with ASME (BPV)Boiler and Pressure Vessel Code. 2.04 CONTROLS A. Locate on chiller, mount steel control panel, containing starters, power and control wiring, molded case disconnect switch,factory wired with single point power connection. B. For each compressor, provide across-the-line starter, non-recycling compressor overload, starter relay,and control power transformer or terminal for controls power. Provide manual reset current overload protection. C. Provide devices on control panel face: l� Fishers Island Community Center 15620 -2 10/20/2006 PACKAGED WATER CHILLERS ,I D. Provide safety controls with indicating lights arranged so any one will shut down machine and require manual reset: E. Provide operating controls: F. Provide pre-piped gage board with pressure gages for suction and discharge refrigerant �. pressures, and oil pressures for each compressor. PART 3 EXECUTION 3.01 INSTALLATION A. Install in accordance with manufacturer's instructions. - B. Provide for connection to electrical service. Refer to Section 16155. C. Install units on vibration isolation. Refer to Section 15072. D. Provide connections to chilled water piping. Refer to Section 15182. E. Arrange piping for easy dismantling to permit tube cleaning. F. Provide piping from chiller safety relief valve to outdoors. Size as recommended by -1 manufacturer. END OF SECTION "i r I I r � f J' Fishers Island Community Center 15620 -3 10/20/2006 PACKAGED WATER CHILLERS ' G SECTION 15720 AIR HANDLING UNITS PART1 GENERAL 1.01 SECTION INCLUDES A. Packaged air handling units. 1.02 SUBMITTALS A. See Section 01300 —Administrative Requirements,for submittal procedures. B. Product Data: 1. Published Literature: Indicate dimensions,weights, capacities, ratings, gages and finishes of materials, and electrical characteristics and connection requirements. C. Shop Drawings: Indicate assembly, unit dimensions,weight loading, required clearances, construction details, field connection details, and electrical characteristics and connection requirements. D. Manufacturer's Instructions: Include installation instructions. E. Maintenance Data: Include instructions for lubrication, filter replacement, motor and drive replacement, spare parts lists, and wiring diagrams. PART2 PRODUCTS 2.01 MANUFACTURERS A. As specified on drawings. B. Substitutions: See Section 01600- Product Requirements. PART 3 EXECUTION 3.01 INSTALLATION A. Install in accordance with manufacturer's instructions. B. Isolate fan section with flexible duct connections. C. Install flexible duct connections between fan inlet and discharge ductwork and air handling unit sections. Ensure that metal bands of connectors are parallel with minimum one inch flex between ductwork and fan while running. D. Make connections to coils with unions or flanges. i END OF SECTION li �r Fishers Island Community Center 15720 - 1 10/20/2006 AIR HANDLING UNITS r i ` SECTION 15810 l ' DUCTS PART1 GENERAL 1.01 SECTION INCLUDES A. Metal ductwork. I B. Nonmetal ductwork. C. Kitchen hood ductwork. D. Duct cleaning. 1.02 REFERENCES A. ASTM A 653/A 653M-Standard Specification for Steel Sheet,Zinc-Coated(Galvanized)or Zinc-Iron Alloy-Coated (Galvannealed)by the Hot-Dip Process. - B. ASTM A 1008/A 1008M-Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability. C. NFPA 90A-Standard for the Installation of Air Conditioning and Ventilating Systems; National Fire Protection Association. D. NFPA 96-Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations; National Fire Protection Association. _ E. SMACNA(DCS)- HVAC Duct Construction Standards- Metal and Flexible; Sheet Metal and Air Conditioning Contractors'National Association. 1.03 PERFORMANCE REQUIREMENTS A. No variation of duct configuration or sizes permitted except by written permission. Size round ducts installed in place of rectangular ducts in accordance with ASHRAE table of equivalent rectangular and round ducts. 1.04 REGULATORY REQUIREMENTS A. Construct ductwork to NFPA 90A standards. 1.05 ENVIRONMENTAL REQUIREMENTS A. Do not install duct sealants when temperatures are less than those recommended by sealant manufacturers. J � B. Maintain temperatures within acceptable range during and after installation of duct sealants. PART2 PRODUCTS 2.01 MATERIALS A. Galvanized Steel Ducts: Hot-dipped galvanized steel sheet,ASTM A 653/A 653M FS Type B, with G60/Z180 coating. B. Steel Ducts: ASTM A 1008/A 1008M, Designation CS, cold-rolled commercial steel. C. Flexible Ducts: 1. UL 181, Class 1, aluminum laminate and polyester film with latex adhesive supported by helically wound spring steel wire. _ a. Pressure Rating: 10 inches WG positive and 1.0 inches WG negative. b. Maximum Velocity: 4000 fpm. Fishers Island Community Center 15810 - 1 10/20/2006 DUCTS c. Temperature Range: -20 degrees F to 210 degrees F. I' D. Insulated Flexible Ducts: 1. UL 181, Class 1, aluminum laminate and polyester film with latex adhesive supported by helically wound spring steel wire; fiberglass insulation; polyethylene vapor barrier film. a. Pressure Rating: 10 inches WG positive and 1.0 inches WG negative. b. Maximum Velocity: 4000 fpm. c. Temperature Range: -20 degrees F to 210 degrees F. 2.02 DUCTWORK FABRICATION A. Fabricate and support in accordance with SMACNA HVAC Duct Construction Standards- Metal and Flexible, and as indicated. Provide duct material,gages, reinforcing, and sealing for operating pressures indicated. B. Construct T's, bends, and elbows with radius of not less than 1-1/2 times width of duct on centerline. Where not possible and where rectangular elbows must be used, provide air foil turning vanes. Where acoustical lining is indicated, provide turning vanes of perforated metal with glass fiber insulation. C. Increase duct sizes gradually, not exceeding 15 degrees divergence wherever possible; maximum 30 degrees divergence upstream of equipment and 45 degrees convergence downstream. D. Fabricate continuously welded round and oval duct fittings two gages heavier than duct gages indicated in SMACNA Standard. Joints shall be minimum 4 inch cemented slip joint, brazed or electric welded. Prime coat welded joints. E. Where ducts are connected to exterior wall louvers and duct outlet is smaller than louver frame, provide blank-out panels sealing louver area around duct. Use same material as duct, painted black on exterior side; seal to louver frame and duct. 2.03 MANUFACTURED METAL DUCTWORK AND FITTINGS A. Manufacture in accordance with SMACNA HVAC Duct Construction Standards- Metal and Flexible, and as indicated. Provide duct material,gages,reinforcing, and sealing for operating pressures indicated. 2.04 KITCHEN HOOD EXHAUST DUCTWORK A. Fabricate in accordance with SMACNA HVAC Duct Construction Standards- Metal and Flexible, and NFPA 96. B. Construct of 16 gage carbon steel or 18 gage stainless steel, using continuous external welded joints. PART 3 EXECUTION 3.01 INSTALLATION A. Duct sizes indicated are inside clear dimensions. For lined ducts, maintain sizes inside lining. B. Install and seal metal and flexible ducts in accordance with SMACNA HVAC Duct Construction Standards-Metal and Flexible. C. Locate ducts with sufficient space around equipment to allow normal operating and maintenance _ activities. D. Connect diffusers or light troffer boots to low pressure ducts directly or with 5 feet maximum , length of flexible duct held in place with strap or clamp. E. Connect flexible ducts to metal ducts with adhesive. Fishers Island Community Center 15810 -2 10/20/2006 DUCTS F. Provide residue traps in kitchen hood exhaust ducts at base of vertical risers with provisions for clean out. G. During construction provide temporary closures of metal or taped polyethylene on open ductwork to prevent construction dust from entering ductwork system. 3.02 CLEANING - A. Clean duct system and force air at high velocity through duct to remove accumulated dust. To obtain sufficient air, clean half the system at a time. Protect equipment which may be harmed by excessive dirt with temporary filters, or bypass during cleaning. END OF SECTION i , Fishers Island Community Center 15810 -3 10/20/2006 DUCTS I.v 1 4 SECTION 15820 DUCT ACCESSORIES PART1- GENERAL 1.01 SECTION INCLUDES - A. Backdraft dampers. r B. Duct access doors. C. Fire dampers. D. Flexible duct connections. E. Volume control dampers. 1.02 REFERENCES A. NFPA 90A-Standard for the Installation of Air Conditioning and Ventilating Systems; National Fire Protection Association. B. SMACNA(DCS)- HVAC Duct Construction Standards- Metal and Flexible; Sheet Metal and Air iConditioning Contractors'National Association. C. UL 555-Standard for Fire Dampers; Underwriters Laboratories Inc.. ' 1.03 SUBMITTALS + A. See Section 01300-Administrative Requirements,for submittal procedures. B. Product Data: Provide for shop fabricated assemblies including volume control dampers. Include electrical characteristics and connection requirements. C. Shop Drawings: Indicate for shop fabricated assemblies including volume control dampers. ? i U ; D. Manufacturer's Installation Instructions: Provide instructions for fire dampers. PART2 PRODUCTS G( i 2.01 BACKDRAFT DAMPERS A. Gravity Backdraft Dampers,,Size 18 x 18 inches or Smaller, Furnished with Air Moving Equipment:Air moving equipment manufacturer's standard construction. 2.02 DUCT ACCESS DOORS A. Fabricate in accordance with SMACNA HVAC Duct Construction Standards-Metal and Flexible, and as indicated. 2.03 FIRE DAMPERS A. Fabricate in accordance with NFPA 90A and UL 555, and as indicated. B. Ceiling Dampers: Galvanized steel, 22 gage frame and 16 gage flap,two layers 0.125 inch i ceramic fiber on top side and one layer on bottom side for round flaps, with locking clip. C. Horizontal Dampers: Galvanized steel, 22 gage frame,stainless steel closure spring, and lightweight, heat retardant non-asbestos fabric blanket. 2.04 FLEXIBLE DUCT CONNECTIONS A. Fabricate in accordance with SMACNA HVAC Duct Construction Standards- Metal and Flexible, and as indicated. 1 ' Fishers Island Community Center 15820 - 1 10/20/2006 DUCT ACCESSORIES Y` I f r ' B. Flexible Duct Connections: Fabric crimped into metal edging strip. 2.05 VOLUME CONTROL DAMPERS A. Fabricate in accordance with SMACNA HVAC Duct Construction Standards- Metal and Flexible, and as indicated. PART 3 EXECUTION 3.01 PREPARATION A. Verify that electric power is available and of the correct characteristics. 3.02 INSTALLATION A. Install accessories in accordance with manufacturer's instructions, NFPA 90A, and follow SMACNA HVAC Duct Construction Standards- Metal and Flexible. Refer to Section 15810 for duct construction and pressure class. B. Provide backdraft dampers on exhaust fans or exhaust ducts nearest to outside and where indicated. C. Provide duct access doors for inspection and cleaning before and after filters, coils,fans, automatic dampers, at fire dampers, combination fire and smoke dampers, and elsewhere as indicated. Provide for cleaning kitchen exhaust ducts in accordance with NFPA 96. Provide minimum 8 x 8 inch size for hand access, 18 x 18 inch size for shoulder access, and as indicated. Provide 4 x 4 inch for balancing dampers only. Review locations prior to fabrication. D. Provide fire dampers at locations indicated,where ducts and outlets pass through fire rated components, and where required by authorities having jurisdiction. Install with required perimeter mounting angles, sleeves, breakaway duct connections, corrosion resistant springs, bearings, bushings and hinges. ! 1 E. Demonstrate re-setting of fire dampers to Town of Southold's representative. _- F. At fans and motorized equipment associated with ducts, provide flexible duct connections immediately adjacent to the equipment. G. At equipment supported by vibration isolators, provide flexible duct connections immediately adjacent to the equipment; see Section 15072. _I H. Provide balancing dampers at points on supply, return, and exhaust systems where branches are taken from larger ducts as required for air balancing. Install minimum 2 duct widths from duct take-off. I. Provide balancing dampers on duct take-off to diffusers, grilles, and registers, regardless of whether dampers are specified as part of the diffuser, grille, or register assembly. j END OF SECTION i i Fishers Island Community Center 15820 -2 10/20/2006 DUCT ACCESSORIES i - SECTION 15835 POWER VENTILATORS - PART1 GENERAL - 1.01 SECTION INCLUDES A. Roof exhausters. B. Cabinet exhaust fans. C. Ceiling exhaust fans. 1.02 SUBMITTALS l ! A. See Section 01300 -Administrative Requirements,for submittal procedures. PART2 PRODUCTS 2.01 MANUFACTURERS -J" A. As scheduled on drawings. 2.02 ROOF EXHAUSTERS A. Roof Curb: 8 inch high self-flashing of galvanized steel with continuously welded seams, built-in cant strips. B. Disconnect Switch: Factory wired, non-fusible, in housing for thermal overload protected motor. -. C. Backdraft Damper: Gravity actuated, aluminum multiple blade construction, felt edged with offset hinge pin, nylon bearings, blades linked, and line voltage motor drive, power open, spring return. r - 2.03 CABINETAND CEILING EXHAUST FANS i A. Centrifugal Fan Unit: V-belt or direct driven with galvanized steel housing lined with acoustic insulation, resilient mounted motor,gravity backdraft damper in discharge. B. Disconnect Switch: Cord and plug in housing for thermal overload protected motor and wall --- mounted switch. - , PART 3 EXECUTION 1" 3.01 INSTALLATION A. Install in accordance with manufacturer's instructions. B. Secure roof exhausters with cadmium plated steel lag screws to roof curb. C. Extend ducts to roof exhausters into roof curb. CounterFlash duct to roof opening. r r D. Provide sheaves required for final air balance. E. Install backdraft dampers on inlet to roof and wall exhausters. ` END OF SECTION t� l� r- Fishers Island Community Center 15835- 1 10/20/2006 POWER VENTILATORS SECTION 15850 AIR OUTLETS AND INLETS PART1 GENERAL 1.01 SECTION INCLUDES A. Diffusers. ,- B. Registers/grilles. C. Roof hoods. 1.02 REFERENCES 1 A. SMACNA(DCS)- HVAC Duct Construction Standards-Metal and Flexible; Sheet Metal and Air Conditioning Contractors'National Association. PART2 PRODUCTS 2.01 MANUFACTURERS - A. Price Industries; as scheduled on drawings. B. Titus; as scheduled on drawings. C. Metalaire; as scheduled on drawings. D. Substitutions: See Section 01600 - Product Requirements. 2.02 ROOF HOODS A. Fabricate air inlet or exhaust hoods in accordance with SMACNA HVAC Duct Construction Standards-Metal and Flexible. j PART 3 EXECUTION 3.01 INSTALLATION A. Install in accordance with manufacturer's instructions. B. Check location of outlets and inlets and make necessary adjustments in position to conform with architectural features, symmetry,and lighting arrangement. C. Install diffusers to ductwork with air tight connection. D. Provide balancing dampers on duct take-off to diffusers, and grilles and registers, despite } whether dampers are specified as part of the diffuser, or grille and register assembly. E. Paint ductwork visible behind air outlets and inlets matte black. Refer to Section 09900. r END OF SECTION s „ i� Fishers Island Community Center 15850 - 1 10/20/2006 AIR OUTLETS AND INLETS s i - SECTION 15950 y' TESTING,ADJUSTING,AND BALANCING PART 1 GENERAL 1.01 SECTION INCLUDES ---l A. Testing, adjustment, and balancing of air systems. il B. Testing, adjustment, and balancing of hydronic systems. C. Measurement of final operating condition of HVAC systems. 1.02 REFERENCES A. AABC MN-1 -AABC National Standards for Total System Balance;Associated Air Balance Council. B. ASHRAE Std 111 -Practices for Measurement, Testing,Adjusting and Balancing of Building Heating, Ventilation,Air-Conditioning,and Refrigeration Systems;American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc.. C. NEBB (TAB) - Procedural Standards for Testing Adjusting Balancing of Environmental Systems; National Environmental Balancing Bureau. t ' 1.03 SUBMITTALS A. See Section 01300 -Administrative Requirements,for submittal procedures. B. TAB Plan: Submit a written plan indicating the testing, adjusting, and balancing standard to be followed and the specific approach for each system and component. _ 1. Include at least the following in the plan: a. List of all air flow,water flow, sound level, system capacity and efficiency j measurements to be performed and a description of specific test procedures, r parameters, formulas to be used. b. Copy of field checkout sheets and logs to be used, listing each piece of equipment to be tested, adjusted and balanced with the data cells to be gathered for each. c. Discussion of what notations and markings will be made on the duct and piping - drawings during the process. _ d. Final test report forms to be used. Ir e. Procedures for formal deficiency reports, including scope, frequency and distribution. C. Final Report: Indicate deficiencies in systems that would prevent proper testing, adjusting, and balancing of systems and equipment to achieve specified performance. 1. Revise TAB plan to reflect actual procedures and submit as part of final report. 2. Submit draft copies of report for review prior to final acceptance of Project. Provide final copies for Design Learned, Inc. and for inclusion in operating and maintenance manuals. 3. Include actual instrument list, with manufacturer name, serial number,and date of calibration. 4. Form of Test Reports: Where the TAB standard being followed recommends a report format use that; otherwise, follow ASHRAE Std 111. 5. Units of Measure: Report data in both I-P(inch-pound)and Sl (metric) units. 6. Test Reports: Indicate data on AABC MN-1 forms, forms prepared following ASHRAE Std 111, or NEBB forms. Submit data in SI (metric) units. 7. Include the following on the title page of each report: a. Name of Testing, Adjusting, and Balancing Agency. b. Address of Testing, Adjusting, and Balancing Agency. i c. Telephone number of Testing,Adjusting, and Balancing Agency. Fishers Island Community Center 15950 - 1 10/20/2006 TESTING, ADJUSTING,AND BALANCING d. Project name. e. Project location. f. Project Contractor. g. Project altitude. h. Report date. D. Project Record Documents: Record actual locations of flow measuring stations and balancing valves and rough setting. 1.04 QUALITY ASSURANCE(moved to PART 3) A. Perform total system balance in accordance with AABC MN-1,ASHRAE Std 111, or NEBB Procedural Standards for Testing, Balancing and Adjusting of Environmental Systems. 1. Maintain one copy of each document on site. B. TAB Agency Qualifications: Company specializing in the testing, adjusting,and balancing of systems specified in this Section with minimum three years documented experience certified by AABC. 1.05 WARRANTY(moved to PART 3) A. Furnish AABC National Performance Guaranty for this project. PART 2 PRODUCTS-NOT USED PART 3 EXECUTION 3.01 GENERAL REQUIREMENTS A. Perform total system balance in accordance with one of the following: B. Begin work after completion of systems to be tested, adjusted, or balanced and complete work prior to Substantial Completion of the project. C. TAB Agency Qualifications: 1. Company specializing in the testing, adjusting,and balancing of systems specified in this section. 3.02 EXAMINATION A. Verify that systems are complete and operable before commencing work. Ensure the following - conditions: 1. Systems are started and operating in a safe and normal condition. 2. Temperature control systems are installed complete and operable. 3. Proper thermal overload protection is in place for electrical equipment. 4. Final filters are clean and in place. If required, install temporary media in.addition to final filters. 5. Duct systems are clean of debris. 6. Fans are rotating correctly. 7. Fire and volume dampers are in place and open. 8. Air coil fins are cleaned and combed. 9. Access doors are closed and duct end caps are in place. 10. Air outlets are installed and connected. 11. Duct system leakage is minimized. 12. Hydronic systems are flushed, filled, and vented. 13. Pumps are rotating correctly. 14. Proper strainer baskets are clean and in place. 15. Service and balance valves are open. B. Submit field reports. Report defects and deficiencies noted during performance of services Fishers Island Community Center 15950 -2 10/20/2006 TESTING, ADJUSTING, AND BALANCING which prevent system balance. C. Beginning of work means acceptance of existing conditions. 3.03 PREPARATION A. Provide additional balancing devices as required. 3.04 INSTALLATION TOLERANCES A. Air Handling Systems: Adjust to within plus or minus 5 percent of design for supply systems and plus or minus 10 percent of design for return and exhaust systems. B. Air Outlets and Inlets: Adjust total to within plus 10 percent and minus 5 percent of design to space. Adjust outlets and inlets in space to within plus or minus 10 percent of design. i 3.05 RECORDING AND ADJUSTING A. Ensure recorded data represents actual measured or observed conditions. i B. Permanently mark settings of valves, dampers, and other adjustment devices allowing settings to be restored. Set and lock memory stops. - C. After adjustment, take measurements to verify balance has not been disrupted or that such disruption has been rectified. D. Leave systems in proper working order; replacing belt guards, closing access doors, closing ` doors to electrical switch boxes, and restoring thermostats to specified settings. 3.06 AIR SYSTEM PROCEDURE - A. Adjust air handling and distribution systems to provide required or design supply, return, and exhaust air quantities at site altitude. B. Make air quantity measurements in ducts by Pitot tube traverse of entire cross sectional area of duct. r ' C. Measure air quantities at air inlets and outlets. D. Adjust distribution system to obtain uniform space temperatures free from objectionable drafts and noise. E. Use volume control devices to regulate air quantities only to extend that adjustments do not create objectionable air motion or sound levels. Effect volume control by duct internal devices such as dampers and splitters. F. Vary total system air quantities by adjustment of fan speeds. Provide drive changes required. Vary branch air quantities by damper regulation. G. Provide system schematic with required and actual air quantities recorded at each outlet or inlet. r H. Adjust outside air automatic dampers, outside air, return air, and exhaust dampers for design conditions. FOLLOW FRESH AIR BALANCING REQUIREMENTS EXACTLY. I. Measure temperature conditions across outside air, return air, and exhaust dampers to check leakage. - J. Where modulating dampers are provided,take measurements and balance at extreme conditions. 3.07 WATER SYSTEM PROCEDURE A. Adjust water systems to provide required or design quantities. Fishers Island Community Center 15950 -3 10/20/2006 TESTING, ADJUSTING,AND BALANCING i B. Use calibrated Venturi tubes, orifices, or other metered fittings and pressure gauges to determine flow rates for system balance. Where flow metering devices are not installed, base flow balance on temperature difference across various heat transfer elements in the system. C. Adjust systems to provide specified pressure drops and flows through heat transfer elements prior to thermal testing. Perform balancing by measurement of temperature differential in conjunction with air balancing. D. Effect system balance with automatic control valves fully open to heat transfer elements. E. Effect adjustment of water distribution systems by means of balancing cocks, valves, and fittings. Do not use service or shut-off valves for balancing unless indexed for balance point. END OF SECTION , Y Fishers Island Community Center 15950 -4 10/20/2006 TESTING, ADJUSTING, AND BALANCING i r i_ SECTION 16070 HANGERS AND SUPPORTS � r PART1 GENERAL V—, 1.01 SECTION INCLUDES r A. Conduit and equipment supports. B. Anchors and fasteners. 1.02 REFERENCES A. NECA 1 -Standard Practices for Good Workmanship in Electrical Contracting; National Electrical Contractors Association. B. NFPA 70-National Electrical Code; National Fire Protection Association. 1.03 QUALITY ASSURANCE -- A. Conform to requirements of NFPA 70. B. Products: Listed and classified by Underwriters Laboratories, Inc. as suitable for the purpose specified and indicated. PART 2 PRODUCTS 2.01 MATERIALS A. Hangers, Supports,Anchors, and Fasteners-General: Corrosion-resistant materials of size and type adequate to carry the loads of equipment and conduit, including weight of wire in conduit. B. Supports: Fabricated of structural steel or formed steel members;galvanized. C. Anchors and Fasteners: f 1. Do not use powder-actuated anchors, spring clips, or beam clamps. - 2. Concrete Structural Elements: Use precast inserts, expansion anchors, or preset inserts. 3. Steel Structural Elements: Use welded fasteners or drilled and screwed fasteners. 4. Concrete Surfaces: Use self-drilling anchors or expansion anchors. 5. Hollow Masonry, Plaster, and Gypsum Board Partitions: Use toggle bolts or hollow wall fasteners. I PART 3 EXECUTION 3.01 INSTALLATION A. Install hangers and supports as required to adequately and securely support electrical system components, in a neat and workmanlike manner, as specified in NECA 1. 1. Do not fasten supports to pipes, ducts, mechanical equipment, or conduit. 2. Do not drill or cut structural members. B. Rigidly weld support members or use hexagon-head bolts to present neat appearance with adequate strength and rigidity. Use spring lock washers under all nuts. 1 END OF SECTION y t, Fishers Island Community Center 16070 - 1 1 0/2 012 0 0 6 HANGERS AND SUPPORTS SECTION 16075 ELECTRICAL IDENTIFICATION PART1 GENERAL 1.01 SECTION INCLUDES A. Wire and cable markers. B. Conduit markers. 1.02 REFERENCES A. NFPA 70- National Electrical Code; National Fire Protection Association. 1.03 QUALITY ASSURANCE A. Conform to requirements of NFPA 70. B. Products: Listed and classified by Underwriters Laboratories, Inc. as suitable for purpose specified and shown. PART2 PRODUCTS 2.01 WIRE MARKERS A. Description: Cloth type wire markers. _.' B. Locations: Each conductor at panelboard gutters, pull boxes, outlet boxes, and junction boxes each load connection. 2.02 CONDUIT MARKERS A. Location: Furnish markers for each conduit longer than 6 feet. r, B. Spacing: 20 feet on center. ti PART 3 EXECUTION END OF SECTION ' I I i i r Fishers Island Community Center 16075 - 1 10/20/2006 ELECTRICAL IDENTIFICATION SECTION 16095 MINOR ELECTRICAL DEMOLITION PART1 GENERAL i" 1.01 SECTION INCLUDES A. Electrical demolition. PART 2 EXECUTION 2.01 EXAMINATION A. Verify that abandoned wiring and equipment serve only abandoned facilities. ' B. Beginning of demolition means installer accepts existing conditions. 2.02 PREPARATION i A. Disconnect electrical systems in walls,floors, and ceilings to be removed. B. Coordinate utility service outages with utility company. C. Provide temporary wiring and connections to maintain existing systems in service during construction. When work must be performed on energized equipment or circuits, use personnel experienced in such operations. D. Existing Electrical Service: Maintain existing system in service until new system is complete and ready for service. Disable system only to make switchovers and connections. Minimize outage duration. 2.03 DEMOLITION AND EXTENSION OF EXISTING ELECTRICAL WORK A. Remove,relocate, and extend existing installations to accommodate new construction. B. Remove abandoned wiring to source of supply. C. Remove exposed abandoned conduit, including abandoned conduit above accessible ceiling finishes. Cut conduit flush with walls and floors, and patch surfaces. --J D. Disconnect abandoned outlets and remove devices. Remove abandoned outlets if conduit servicing them is abandoned and removed. Provide blank cover for abandoned outlets which are not removed. E. Repair adjacent construction and finishes damaged during demolition and extension work. F. Maintain access to existing electrical installations which remain active. Modify installation or provide access panel as appropriate. END OF SECTION i L_ Fishers Island Community Center 16095- 1 10/20/2006 MINOR ELECTRICAL DEMOLITION I l r-, SECTION 16123 ` BUILDING WIRE AND CABLE PART1 GENERAL 1.01 SECTION INCLUDES A. Wire and cable for 600 volts and less. - B. Wiring connectors and connections. 1.02 REFERENCES -- A. NECA 1 -Standard Practices for Good Workmanship in Electrical Contracting; National Electrical Contractors Association. B. NFPA 70- National Electrical Code; National Fire Protection Association. i 1.03 SUBMITTALS - A. See Section 01300-Administrative Requirements,for submittal procedures. B. Project Record Documents: Record actual locations of components and circuits. 1.04 QUALITY ASSURANCE A. Conform to requirements of NFPA 70. B. Products: Furnish products listed and classified by Underwriters Laboratories Inc. as suitable for the purpose specified and indicated. r- PART2 PRODUCTS 2.01 WIRING REQUIREMENTS ( A. Concealed Dry Interior Locations: Use only building wire in raceway or metal clad cable. B. Exposed Dry Interior Locations: Use only building wire in raceway. f C. Above Accessible Ceilings: Use only building wire in raceway or metal clad cable. - ' D. Wet or Damp Interior Locations: Use only metal clad cable. E. Use conductor not smaller than 12 AWG for power and lighting circuits. I F. Use 10 AWG conductors for 20 ampere, 120 volt branch circuits longer than 75 feet. G. Conductor sizes are based on copper unless indicated as aluminum or"AL". 2.02 BUILDING WIRE A. Description: Single conductor insulated wire. B. Conductor: Copper. C. Insulation Voltage Rating: 600 volts. i 2.03 METAL CLAD CABLE r A. Description: NFPA 70, Type MC. B. Conductor: Copper. C. Insulation Voltage Rating: 600 volts. D. Insulation Temperature Rating: 60 degrees C. Fishers Island Community Center 16123 - 1 10/20/2006 BUILDING WIRE AND CABLE E. Insulation Material: Thermoplastic. F. Armor Material: Steel. G. Armor Design: Interlocked metal tape. _f PART 3 EXECUTION - 3.01 EXAMINATION A. Verify that interior of building has been protected from weather. B. Verify that mechanical work likely to damage wire and cable has been completed. C. Verify that raceway installation is complete and supported. 3.02 PREPARATION i i A. Completely and thoroughly swab raceway before installing wire. 3.03 INSTALLATION A. Install wire and cable securely, in a neat and workmanlike manner, as specified in NECA 1. B. Route wire and cable as required to meet project conditions. 1. Wire and cable routing indicated is approximate unless dimensioned. 2. Where wire and cable destination is indicated and routing is not shown, determine exact routing and lengths required. 3. Include wire and cable of lengths required to install connected devices within 10 ft of location shown. C. Use wiring methods indicated. D. Pull all conductors into raceway at same time. E. Use suitable wire pulling lubricant for building wire 4 AWG and larger. F. Use suitable cable fittings and connectors. _ G. Neatly train and lace wiring inside boxes, equipment, and panelboards. H. Clean conductor surfaces before installing lugs and connectors. I. Make splices,taps, and terminations to carry full ampacity of conductors with no perceptible temperature rise. J. Use split bolt connectors for copper conductor splices and taps, 6 AWG and larger. Tape uninsulated conductors and connector with electrical tape to 150 percent of insulation rating of conductor. K. Use insulated spring wire connectors with plastic caps for copper conductor splices and taps, 10 AWG and smaller. � I L. Identify and color code wire and cable under provisions of Section 16075. Identify each conductor with its circuit number or other designation indicated. END OF SECTION r Fishers Island Community Center 16123 -2 } 10/20/2006 BUILDING WIRE AND CABLE SECTION 16131 CONDUIT - PART1 GENERAL 1.01 SECTION INCLUDES A. Conduit,fittings and conduit bodies. 1.02 RELATED SECTIONS A. Section 16070 - Hangers and Supports. B. Section 16075 -Electrical Identification. C. Section 16138- Boxes. 1.03 REFERENCES A. ANSI C80.1 -American National Standard for Electrical Rigid Steel Conduit(ERSC). B. ANSI C80.3-American National Standard for Steel Electrical Metallic Tubing (EMT). C. NECA 1 -Standard Practices for Good Workmanship in Electrical Contracting; National Electrical Contractors Association. D. NECA 101 -Standard for Installing Steel Conduit(Rigid, IMC, EMT); National Electrical Contractors Association. E. NEMA FB 1 - Fittings, Cast Metal Boxes, and Conduit Bodies for Conduit, Electrical Metallic Tubing, and Cable; National Electrical Manufacturers Association. F. NEMA TC 2- Electrical Polyvinyl Chloride(PVC)Tubing and Conduit; National Electrical Manufacturers Association. G. NEMA TC 3-PVC Fittings for Use with Rigid PVC Conduit and Tubing; National Electrical Manufacturers Association. H. NFPA 70- National Electrical Code; National Fire Protection Association. 1.04 QUALITY ASSURANCE A. Conform to requirements of NFPA 70. B. Products: Listed and classified by Underwriters Laboratories, Inc. as suitable for purpose specified and shown. PART2 PRODUCTS 2.01 CONDUIT REQUIREMENTS A. Conduit Size: Comply with NFPA 70. 1. Minimum Size: 1/2 inch unless otherwise specified. B. Underground Installations: 1. In or Under Slab on Grade: Use rigid steel conduit or thickwall non-metallic conduit. C. Outdoor Locations Above Grade: Use rigid steel conduit. D. Wet and Damp Locations: Use rigid steel conduit or thickwall nonmetallic conduit. E. Dry Locations: 1. Concealed: Use rigid steel conduit, electrical metallic tubing, or thickwall nonmetallic conduit. Fishers Island Community Center 16131 - 1 10/20/2006 CONDUIT 2. Exposed: Use rigid steel conduit, electrical metallic tubing, or thickwall nonmetallic conduit. 2.02 METAL CONDUIT A. Rigid Steel Conduit: ANSI C80.1. B. Fittings and Conduit Bodies: NEMA FB 1; material to match conduit. 2.03 ELECTRICAL METALLIC TUBING(EMT) A. Description: ANSI C80.3; galvanized tubing. B. Fittings and Conduit Bodies: NEMA FB 1; steel or malleable iron compression type. 2.04 NONMETALLIC CONDUIT A. Description: NEMA TC 2; Schedule 40 PVC. B. Fittings and Conduit Bodies: NEMA TC 3. PART 3 EXECUTION 3.01 EXAMINATION A. Conduit routing is shown on drawings in approximate locations unless dimensioned. Route as required to complete wiring system. 3.02 INSTALLATION A. Install conduit securely, in a neat and workmanlike manner, as specified in NECA 1. B. Install steel conduit as specified in NECA 101. C. Install nonmetallic conduit in accordance with manufacturer's instructions. i_ D. Arrange supports to prevent misalignment during wiring installation. E. Support conduit using coated steel or malleable iron straps, lay-in adjustable hangers, clevis hangers, and split hangers. F. Group related conduits; support using conduit rack. Construct rack using steel channel; provide -- space on each for 25 percent additional conduits. G. Fasten conduit supports to building structure and surfaces under provisions of Section 16070. H. Do not support conduit with wire or perforated pipe straps. Remove wire used for temporary supports. I. Do not attach conduit to ceiling support wires. J. Arrange conduit to maintain headroom and present neat appearance. K. Route exposed conduit parallel and perpendicular to walls. L. Route conduit installed above accessible ceilings parallel and perpendicular to walls. M. Route conduit in and under slab from point-to-point. N. Maintain adequate clearance between conduit and piping. ! O. Cut conduit square using saw or pipecutter;de-burr cut ends. P. Bring conduit to shoulder of fittings; fasten securely. Q. Install no more than equivalent of three 90 degree bends between boxes. Use conduit bodies to make sharp changes in direction, as around beams. Use hydraulic one shot bender to fabricate -- bends in metal conduit larger than 2 inch size. !, Fishers Island Community Center 16131 -2 10/20/2006 CONDUIT R. Avoid moisture traps; provide junction box with drain fitting at low points in conduit system. S. Provide suitable fittings to accommodate expansion and deflection where conduit crosses seismic. T. Provide suitable pull string in each empty conduit except sleeves and nipples. U. Use suitable caps to protect installed conduit against entrance of dirt and moisture. V. Identify conduit under provisions of Section 16075. END OF SECTION I Fishers Island Community Center 16131 -3 10/20/2006 CONDUIT r� I ' i SECTION 16138 BOXES PART1 GENERAL 1.01 SECTION INCLUDES A. Wall and ceiling outlet boxes. B. Pull and junction boxes. 1.02 RELATED SECTIONS A. Section 16139-Cabinets and Enclosures. j' B. Section 16140 -Wiring Devices: Wall plates in finished areas. 1.03 REFERENCES A. NECA 1 -Standard Practices for Good Workmanship in Electrical Contracting; National Electrical Contractors Association. B. NEMA FB 1 -Fittings, Cast Metal Boxes, and Conduit Bodies for Conduit, Electrical Metallic Tubing, and Cable; National Electrical Manufacturers Association. C. NEMA OS 1 -Sheet Steel Outlet Boxes, Device Boxes, Covers,and Box Supports; National Electrical Manufacturers Association. - D. NEMA 250- Enclosures for Electrical Equipment(1000 Volts Maximum); National Electrical Manufacturers Association. E. NFPA 70- National Electrical Code; National Fire Protection Association. 1.04 SUBMITTALS A. Project Record Documents: Record actual locations and mounting heights of outlet, pull, and junction boxes on project record documents. 1.05 QUALITY ASSURANCE A. Conform to requirements of NFPA 70. B. Products: Provide products listed and classified by Underwriters Laboratories, Inc., as suitable for the purpose specified and indicated. PART2 PRODUCTS 2.01 OUTLET BOXES A. Sheet Metal Outlet Boxes: NEMA OS 1, galvanized steel. B. Cast Boxes: NEMA FB 1, Type FD, aluminum. Provide gasketed cover by box manufacturer. Provide threaded hubs. C. Wall Plates for Finished Areas: As specified in Section 16140. 2.02 PULL AND JUNCTION BOXES A. Sheet Metal Boxes: NEMA OS 1, galvanized steel. B. Surface Mounted Cast Metal Box: NEMA 250, Type 4; flat-flanged, surface mounted junction box: 1. Material: Galvanized cast iron. 2. Cover: Furnish with ground flange, neoprene gasket, and stainless steel cover screws. I_ Fishers Island Community Center 16138 - 1 10/20/2006 BOXES `I 1 i PART 3 EXECUTION 3.01 INSTALLATION A. Install boxes securely,in a neat and workmanlike manner, as specified in NECA 1. _f B. Install in locations as shown on Drawings,and as required for splices, taps, wire pulling, equipment connections, and as required by NFPA 70. C. Coordinate installation of outlet boxes for equipment connected under Section 16155. D. Set wall mounted boxes at elevations to accommodate mounting heights indicated. I E. Electrical boxes are shown on Drawings in approximate locations unless dimensioned. _J F. Orient boxes to accommodate wiring devices oriented as specified in Section 16140. G. Maintain headroom and present neat mechanical appearance. - H. Install pull boxes and junction boxes above accessible ceilings and in unfinished areas only. I. Locate outlet boxes to allow luminaires positioned as shown on reflected ceiling plan. J. Align adjacent wall mounted outlet boxes for switches,thermostats, and similar devices. K. Use flush mounting outlet box in finished areas. L. Do not install flush mounting box back-to-back in walls; provide minimum 6 inches separation. Provide minimum 24 inches separation in acoustic rated walls. M. Secure flush mounting box to interior wall and partition studs. Accurately position to allow for surface finish thickness. N. Install flush mounting box without damaging wall insulation or reducing its effectiveness. O. Use adjustable steel channel fasteners for hung ceiling outlet box. J 9 9 P. Do not fasten boxes to ceiling support wires. Q. Support boxes independently of conduit. R. Use gang box where more than one device is mounted together. Do not use sectional box. i S. Large Pull Boxes: Use hinged enclosure in interior dry locations, surface-mounted cast metal box in other locations. 3.02 CLEANING A. Clean interior of boxes to remove dust, debris, and other material. B. Clean exposed surfaces and restore finish. END OF SECTION - Fishers Island Community Center 16138 -2 ° 10/20/2006 BOXES SECTION 16140 WIRING DEVICES PART1 GENERAL 1.01 SECTION INCLUDES A. Wall switches. B. Device plates and decorative box covers. 1.02 RELATED SECTIONS A. Section 16138 - Boxes. 1.03 REFERENCES A. NECA 1 -Standard Practices for Good Workmanship in Electrical Contracting; National Electrical Contractors Association. - B. NEMA WD 1 -General Color Requirements for Wiring Devices;.National Electrical Manufacturers Association. C. NFPA 70- National Electrical Code; National Fire Protection Association. 1.04 QUALITY ASSURANCE A. Conform to requirements of NFPA 70. B. Products: Provide products listed and classified by Underwriters Laboratories, Inc. as suitable for the purpose specified and indicated. PART 2 PRODUCTS 2.01 WALL SWITCHES A. Wall Switches: General Duty, AC only general-use snap switch, complying with NEMA WD 6 and WD 1. 1. Body and Handle: Ivory plastic with toggle handle. 2. Ratings: a. Voltage: 120 volts,AC. b. Current: 20 amperes. B. Switch Types: Single pole. PART 3 EXECUTION 3.01 EXAMINATION A. Verify that outlet boxes are installed at proper height. B. Verify that wall openings are neatly cut and will be completely covered by wall plates. C. Verify that branch circuit wiring installation is completed,tested, and ready for connection to wiring devices. 3.02 INSTALLATION A. Install securely, in a neat and workmanlike manner, as specified in NECA 1. B. Install devices plumb and level. C. Install switches with OFF position down. Fishers Island Community Center 16140 - 1 10/20/2006 WIRING DEVICES D. Install decorative plates on switch, receptacle, and blank outlets in finished areas. E. Connect wiring devices by wrapping conductor around screw terminal. i 3.03 INTERFACE WITH OTHER PRODUCTS A. Coordinate locations of outlet boxes provided under Section 16138 to obtain mounting heights specified. B. Install wall switch 48 inches above finished floor. 3.04 FIELD QUALITY CONTROL A. Perform field inspection, testing, and adjusting in accordance with Section 01400. B. Inspect each wiring device for defects. _ C. Operate each wall switch with circuit energized and verify proper operation. 3.05 ADJUSTING A. Adjust devices and wall plates to be flush and level. 3.06 CLEANING A. Clean exposed surfaces to remove splatters and restore finish. END OF SECTION i II Fishers Island Community Center 16140 -2 10/20/2006 WIRING DEVICES - SECTION 16510 INTERIOR LUMINAIRES PART1 GENERAL 1.01 SECTION INCLUDES A. Interior luminaires and accessories. -. B. Emergency lighting units. I_ ` C. Exit signs. D. Ballasts. E. Fluorescent dimming ballasts and controls. F. Lamps. G. Luminaire accessories. 1.02 REFERENCES A. ANSI C82.1 -American National Standard for Lamp Ballast- Line Frequency Fluorescent Lamp Ballast. B. NECA/IESNA 500- Recommended Practice for Installing Indoor Commercial Lighting Systems; I National Electrical Contractors Association. C. NFPA 70-National Electrical Code; National Fire Protection Association. D. NFPA 101 -Code for Safety to Life from Fire in Buildings and Structures; National Fire Protection Association. 1.03 SUBMITTALS A. See Section 01300 -Administrative Requirements,for submittal procedures. 1.04 QUALITY ASSURANCE j A. Conform to requirements of NFPA 70 and NFPA 101. B. Products: Listed and classified by Underwriters Laboratories, Inc. as suitable for the purpose specified and indicated. 1.05 EXTRA MATERIALS - A. See Section 01600 - Product Requirements,for additional provisions. j B. Furnish two replacement lamps for each lamp type. C. Furnish two of each ballast type. PART2 PRODUCTS 2.01 LUMINAIRES i A. Luminaire: Fluorescent<>type luminaire. 1. Mounting: Pendant. r 2. Ballast: Manufacturer's standard, matched to lamp characteristics, rated 120 volts. 3. Gasketing: Between enclosure and frame and between frame and luminaire housing. 4. Installation Conditions: Wet Location. 5. Product:As specified on drawings. 6. Substitutions: See Section 01600-Product Requirements. f Fishers Island Community Center 16510 - 1 10/20/2006 INTERIOR LUMINAIRES 2.02 EXIT SIGNS —' A. Exit Signs: Exit sign fixture suitable for use as emergency lighting unit. 1. Housing: Extruded aluminum. 2.03 BALLASTSAND CONTROL UNITS A. Fluorescent Ballasts: ANSI C82.1, high power factor type electromagnetic ballast, suitable for lamps specified. 1. Voltage: 120 volts. 2. Certify fluorescent ballast design and construction by Certified Ballast Manufacturers, Inc. 3. Substitutions: See Section 01600 -Product Requirements. 2.04 LAMPS A. Lamp Types: As specified for each luminaire. PART 3 EXECUTION 3.01 INSTALLATION A. Install fixtures securely,in a neat and workmanlike manner, as specified in NECA 500 (commercial lighting). j B. Install suspended luminaires and exit signs using pendants supported from swivel hangers. Provide pendant length required to suspend luminaire at indicated height. C. Install surface mounted luminaires and exit signs plumb and adjust to align with building lines and with each other. Secure to prevent movement. - D. Exposed Grid Ceilings: Support surface mounted luminaires in grid ceiling directly from building structure. E. Install accessories furnished with each luminaire. F. Make wiring connections to branch circuit using building wire with insulation suitable for temperature conditions within luminaire. G. Bond products and metal accessories to branch circuit equipment grounding conductor. - H. Install specified lamps in each luminaire. I. Interface with air handling accessories furnished and installed under Section 15840. - I 3.02 FIELD QUALITY CONTROL A. Operate each luminaire after installation and connection. Inspect for proper connection and operation. ' I 3.03 CLEANING A. Clean electrical parts to remove conductive and deleterious materials. B. Remove dirt and debris from enclosures. - C. Clean finishes and touch up damage. 3.04 DEMONSTRATION AND INSTRUCTIONS A. Demonstrate luminaire operation for minimum of two hours. - 3.05 PROTECTION A. Relamp luminaires that have failed lamps at Substantial Completion. I Fishers Island Community Center 16510 -2 10/20/2006 INTERIOR LUMINAIRES END OF SECTION 1 - J Fishers Island Community Center 16510 -3 10/20/2006 INTERIOR LUMINAIRES NEW EXIT SIGN aa 'aa � a O Qa � U8cl 0 0 a Q 4 a a 4 0 1 `l� 6J J SECOND FLOOR ❑H o 9 ❑ ❑ ❑ ❑ ❑ ❑ 09 NEW EXIT SIGN FIRST FLOOR z if f 0 i i : `rrtpa U�NI}TY BEN �� 0' 50' 100, 07, I �$1 '• �. jI%• 1� �� e ( 4 O�\,ley i D� r arm t „ti( ~F E + O b=r.. SCHEMATIC DESIGN 05.28.05 c xV-i I r daA i.r \ SCHEMATIC DESIGN 05.20.05 Q'I � 1;:`r.iF 4:.F • JJ •'� r='� [ . '1` �r lA, �� S rfY �.ir✓fi X }T'�4 .t PEVRION ISSUE D41F COMMUNITY CENTER _ Fisher's Island New York ai C�S a �.a' �-�', e &• see'a' � �—� r Ltd � SN `�� ti. �I Yam i SCC` OL T` ti,1f r O 9�j X�cV •r! - � 7F , ,F% � 1 EE] t i KINLIN RUTHERFURD ARCHITECTS r TO FIS ER'S ISLAND 145 WEST 30TH STREET,11TH FLOOR YORK NEW (212 695-2 K 10001 988 E EX CIS PATH FAX(775)582-1736 WHISTLER AVENUE ------------ m SITE PLAN ai N HALF SCALE a 01 SITE PLAN A020 Of m m PROJECT:46 0 r• E N8 M r ' - r^ C)00 G ' co j C N s �0 U �`' toco � ,moo\ �Q ,� � •� '� o C:) 4 " 0 v I- N/F �P� "9Q �, ..�; �� rJ .co TOWN OF + R�2o,o • SOUTHOLD PQQe° �, 3. 40. o a�i' zc 0o v � ai S 47'53'19" W \ M;- cc i N 47*01'19" W \ p1 as S 63'31'00" E h`1'op 7.00 1#/ �� N F �/ UNION FREE LOCATION MAP SCALE 1 "=400' h SCHOOL DISTRICT s MAP RED•RFC �<-O NENEII N H. s ��' APPROX. LOCATION S 3J3.53 1.) SITE PLAN PREPARED FOR FIDCO-BLDG 98, FOX LANE; FISHERS ISLAND, S 6" SEWER LINE W 6394.72 NEW Y(1RK; CHANDLER, PALMER & KING; NORWICH, CT.; DATE; FEBRUARY 2, t,.;d.• m TO PUMP STATION .; • 1993; SCALE: 1"=20', SHEET 1 OF 1/Z .' «9 / ���/ 2.) PUN OF PROPERTY TO BE CONVEYED BY FISHERS ISLAND DEVELOPMENT, N/F CAROLINE C. �/ CORP. I0 CAROLINE C. CLEVELAND, LOTS 5A & 5B - FORT WRIGHT AREA r` r TOWN OF CLEVELAND °+•j \ FISHERS ISLAND, NEW YORK. SCALE: 1"=40'. JAN. 8, 1971 BY CHANDLER & S�`���v �,\\ SOUTHOLD / P// �� \ PALMER ENG'RS. ADDITIONS FEB. 1, 1971. N 40'1520" W 3.) PLAN OF A PORTION OF THE FORMER FORT H. G. WRIGHT PROPERTY FOR 8.11• THE RA:;E POINT CORPORATION FISHERS ISLAND - TOWN OF SOUTHOLD, NEW POLE k / 4 YORK. SCALE: 1"=40', CHANDLER & PALMER, ENG'RS. NORWICH, CONN. DECEMBF-R 1966, ADDITIONS 2/9/78. • / U 4.) PLAN OF PROPERTY TO BE CONVEYED TO FISHERS ISLAND FERRY DISTRICT, z 0 • � GREENWOOD ROAD AND SILVER ELL COVE FISHERS ISLAND, NEW YORK. SCALE: ?`S4po RR• MAN HOLE 1"=40'. CHANDLER, PALMER & KING NORWICH, CONNECTICUT DEC. 15, 1983. SPIKE APPROX. LOCATION / . � � 6" SEWER LINE / po s PER MAP REF. J7 / oo' •� 5.) PLAN OF PROPERTY TO BE CONVEYED BY CAROLINE C. CLEVELAND TO BASIN �\ s (SEE SHEET 1 OF 2) ,�k% FISHERS ISLAND UNION FREE SCHOOL DISTRICT NO. 4 FISHERS ISLAND, N.Y. V-1 PALMER & KING FEB. 5, 1974. / g k SCALE: 1"=40'. CHANDLER, N/F MANHOLE �A� . MANHOLE // 6.) PLAN OF PROPERTY TO BE CONVEYED BY RACE POINT CORPORATION TO W V \ TJS ENTERPRISES, INC. °" F MANHOLE® // � N/F CAROLINi C. CLEVELAND FORT WRIGHT AREA FISHERS ISLAND N.Y. SCALE: V 1 =40 . CHANDLER & PALMER ENG'RS. JULY 1967. Y Z CAROLINE C. Z o O ro CLEVELAND 7.) WASl�: WATER TREATMENT FACILITIES FOR FISHERS ISLAND DEVELOPMENT POLECL CORPORa;"ION NEW YORK, DATE: 4/1976, SCALE: 1"=40', SHEET N0. A-2, JC (v �,O�O \ r - x 6.37 / SOMMER., ASSOCIATES INC. VERNON, CT. f.; p *�, w CATCH / `� V- W Z Z BASIN W ,O >< : z Qp . :_`:<;sY:S"�'..rat'�',.':%r£`5�. Y<�` t.>1;...�4•J,.: :'i<y it<:: �I/n'�'�c ^ •\ >#3x--Y%.;:`j:FiS.: -13': `.Aa.tr ,.ij:.`, ::."' / L � w ` 11^ l7 _:.j �tn .:i$<:.�'t:::. .:2.��.�i�::::."'`r :�:.c' / • " `" \ ti� -7L a 7 aj x 8.12 / S 40'29 10 E 1.) THIS SURVEY WAS PREPARED FOR THE PARTIES AND PURPOSE INDICATED O V < .: ' c>.<f:_ •<*;r.< :> :°,.,y-9> 1 45' HEREON. -� Q x ANY EXTENSION OF THE USE BEYOND THE PURPOSED AGREED TO W Q. p N v BETWEEN w _ G _ >; .. :>,,. ....<.:>r.< <:;,.::• / THE CLIENT AND THE SURVEYOR EXCEEDS THE SCOPE OF THE J+- m x 7.1 x 6.44 ENGAGEMENT. 0 U w \ \� ..>-.: s.::=`c::.':>:`y:aye`,.":,,.:::< '.:>:::'sr»•:< ;:'x':;e: 2.) IT IS A VIOLATION OF THE STATE EDUCATION LAW FOR ANY PERSON, UNLESS I-.. Q = I"- - ACTING UNDER THE DIRECTION F 0 A LICENSED LAND SURVEYOR, TO ALTER AN V) N (n \ �\`I' ITEM IN ANY WAY. L� X 7.32 :, Y a2 `` EXiSTfNls J3t1lL1NG _ a G APPROX. F: ;.`': „: t},' 5'} WATER LINE / AREA SUBJECT TO EASEMENT 3.) ONLY COPIES OF THIS SURVEY MARKED WITH THE LAND SURVEYOR'S w 0 AS DESCRIBED IN LIBER 10216 SIGNATURE AND AN ORIGINAL EMBOSSED OR INK SEAL ARE THE PRODUCT OIF V) x \ k a / o :E 6.96 PAGES 331-332 \ £ � / THE LAND SURVEYOR. POLE \ E !>%:.r5?::'e.C?;<i'rz:ii>vi;'':- <:.�'!'::>SI:>3-^.;?:ita°i<ta .is'ai�;:'s.<:;:;s; / J MON. \ ::. ;,, ;�;,;.ri:.. :; , , ; , w ,,�_. 0 4.) COORDINATE DISTANCES ARE MEASURED FROM U.S. COAST AND GEODETIC (NOT FOUND ] SURVEY.TRIANGULATION STATION "PROS" a LJJ 5. SITE IS IN THE TOWN OF SOUTHOLD COUNTY F) COU 0 SUFFOLK TAX MAP 1000 '4 0 SECTION 012 BLOCK 1 LOT 5.1 S�� x 7.06 `r s ro: �C' POLE Ok G ' ' V/ ?DOS R.R ":'; - $ ` . z &:_: / x 7.36489 ��j • ��\C� / SPIKE �� 6.) TOTAL AREA 1.28t ACRES. L�•. G p� 7. SITE IS LOCATED RXlY ) N B ZONE. 8.) BASE FOR LEVELS: N V cc G D 1929. 9.) PORTIONS OF SITE ARE LOCATED WITHIN AE (10) PER FIRM PANEL 18-1026, 0 as<.. .:. z �G MANHOL v a > mi = m � OWNER a Q 7.51 ATCH NSF FISHERS ISLAND DEVELOPMENT CORP. Z z 0 m m m BENCHMARK x 7.0 MON. BASIN (FOUND) UNION FREE C/O F.I. UTILITY COMPANY O _ 0 0 RAILROAD SPIKE I �� � ' ELEVATION = 7.22 \ x 7.34 3 �\�Go SCHOOL DISTRICT DRAWERIFISHERS ISLAND, NY 06390 d � 0 w w Z g g w w Y a n / � N o o � z z � w T m a a m M.H Ilk o 0 M.H t� t� W a `flip I POLE 490 Q \ \ o 0 0 0 0 I # o \ o a M•® x 7.75 S 40'43'19" E 10 N M c \ Z N I ,J POLE #359 Q � GUY S 66'53'35' W ~ q 0 0 / Q o z LL- m N I I Ce I N ' c^�^ 0 O O _J J W Z z Z Y \ Z w O w w -r p -� N/F NOW OR FORMERLY cl m o 0 0 u � SF SQUARE FEET DATE: 06/23/2006 x 7.07 ELEVATION SPOT GRADE SCALE: 1 = 30' QUALITY CONTROL CERTIFICATION a- EXISTING FENCE GROUP REVIEWED AT PROJECT MANAGER �7 .0 17 SURVEY > ENVIRONMENTAL 30 15 0 30 SHEET CIVIL 1 V F 2 STRUCTURAL ' GRAPHIC SCALE IN FEET ARCHITECTURAL FILE 35087 CAST IRON FRAME AND COVER TO GRADE SIGNAGE WILL BE PROVIDED N ti E BUOYANCY CALCULATIONS- ASSUME 3 F FOR PEDESTRIAN SAFETY M FEET INTO GROUND WATEFR7 GRAVEL FILL C1i N FINISHED GRADE WEIGHT OF VOLUME DISPLACED- 4 X 4 X 3.14 X 3 X 62.4= 9405 LBS. m WEIGHT OF GREASE TRAP= (4 X 4 X 3.14 X 7.25) - (3.5 X 3.5 X 3.14 X 6) = BACKF I LL 45• NORMAL 133.5 X 150 LBS./CU. FT. = 20,000 LBS. 24" . 24.. ` WYE OR TEE AS ORDERED 00 c SAFETY FACTOR 2.1 DIA. ' DIA. 8" • F I TT I NORMAL CONNECTION co ED O LATERAL J, 0 c y FROM KITCHEN- 4" DIA. PITCHED MIN. 1/4'/1' FLOW SEWER O ' a 12" LIQUID LEVEL T TO SEWER -'- ,rO\ 0Q � 1/4' PER FT � •� l 1/4' PER FT 6' �p� .��OO �O �y • Fad EDGE OF i•i TRENCH I N/F - 4 I--6" 8' DIA. �-8" INSTALL BEND g. TOWN OF 6 �s20.0 Uj w m MIN. MONOLITH CAN. AS REQUIRED - SOUTHOLD o+ �. 3'13 a o CROSS SECTION 6' CONNECTION LIMIT OF PAYMENT FLAT CONNECTION LATERAL PQe� CC3 Q M U LATERAL CONNECTION LATERAL ONLY WHEN DIRECTE© BY FOUNDATION STONE O \ / •U 8 Y ENGINEER AS REQUIRED ,p V 'Q C� 1- CAP AT LOCATION �O� k O 1000 GALLON AOBE '�� o° Fti � '' v `� H-20 GREASE TRAP PLAN DIRECTED Y SECT ION �� �°' \ �yoo c1d VV g NOT TO SCALE USE TEE ONLY WHEND EC ED B y1 1 'S THE ENGINEER OR OTHEW I SE SPECIFIED S 4753'19" W \ ,A M-i l`fi 4., 0 N 4701'19" WCc \ �90 W PLANTING SCHEDULE 3 � �„�„� ,,µ,E ,,�,� SEWER LATER L o PUN LABEL COMMON NAIAE BOO i� 04 PS #1 NEWPORT PURPLE-LEAF PLUM PRUNUS CERASIFERA NOT TO SCALE m 04 S 63'31000" E tipp N/F �:;;�fi. ch 1� �`1 � 7.00 '`�•��/ UNION FREE { I PS #2 FLOWERING DOGWOOD CCJRNUS FLORIDA I`� SCHOOL DISTRICTx 'zt `v.,,f 5 {�} PS #3 LITTLE GEM ARBORVITAE THIUJA OCCIDENTALIS 'LITTLE GEM' 6 FT. MIN. HEIGHT S 0 PS #4 CRIMSON PYGMY BARBERRY BERBERIS THUNBERGII 'ATROPURPUREA NANA' x„ PS #5 BLUE CARPET JUNIPER JUNIPERUS SQUAMATA 'BLUE CARPET' COVER AREA SHOWN 44.., APPROX. LOCATION ��� S 38.53 LOCATION MAP SCALE 1 "=4010' PS #6 GOLDEN JUNIPER JUNIPERUS CHINENSIS 'PLUMOSA AUREA' S 6' SEWER LINE W 6394.72 TO PUMP STATION PS #7 DWARF BURNING BUSH EUONYMUS ALATUS 'COMPACTUS' O� 4 PS #8 CRIMSON RED AZALEA AZALEA HUBRID 'CRIMSON RED' N/F N/F CAROLINE C. �,� {? PS #9 COMPACT PJM RHODODENDRON RHODODENDRON 'PJM COMPACTA' TOWN OF CLEVELAND / PARKING CALCULATIONS ''" INV. IN-3.50 N�� SOUTHOLD Q`�j/ �� \ Vic;`" FfoG�^ f# PS #10 DWARF GLOBE BLUE SPRUCE PIICEA PUNGENS 'GLOBOSA' / P� \ LOCATION PROVIDE 6 �, N 40'15 20 W r 1 • • � / r COMMERCIAL RECREATION SEWER LINE PROPOSED FENCE W/ SIGNAGE + / UTILITY , p 8,11 BOWLING ALLEY 3656 POLE AND BIKE RACK) / / PROVIDE HEAVY DUTY 1000 GAL 2 MANHOLE pe, / CAFE 625 H-20 GREASE TRAP FOR KITCHEN DRAINS PROPOSED a ��0' / FOOD PREPARATION 139 W/ CAST IRON FRAMES AND COVERS TO GRADE g LAPIOSCAPEO AREAS // p0 TEEN'S CENTER 830 7 INV. IN=4.50 14� (SEE PLANTING SCHEDULES / POLE ,��p' CHILDREN'S CENTER 321 `S INV. OUT-4.0 'off 2S,0 �' R. / I278 FITNESS CENTER 1375 PROPOSED si\ 5P1 APPROX. LOCATION / y�, DANCE STUDIO 626 EDGE OF NEW PAVEMENT �\ 6" SEWER LINE ��/ ARTS & CRAFTS 476 CATCH \ SEWER PER MAP REF. #7 ���p SEATING (INCLUDED IN BOWLING ALLEY) / (SEE SHEET 1 OF 2) �/ V 9 FlLTER FABRIC TO BE PROPOSED STAIR TOWER A ° E MANHOLE / INSTALLED UNDER SERVICE COUNTER (INCLUDED IN CAFE) (� N/F (SEE ARCHITECTURAL PLANS) y / 5 TOTAL: 8048 \ CATCH BASIN GRATE Z \ T.IS ENTERPRISES, INC. PROPosEp DUMPSTER �a� MANHOLE // \� \ \ PARKING REQUIRED (1 PER 300) 27 op r , / �P \ \ \ NIF CONCRETE BLOCK STORAGE \ CAROLINE C. CONCRETE BLOCK \ PROPOSED LOADING DOCK 3 ;. F / �P \ / PAVEMENT STORAGE 557 POLE s>_r' 'y `w / G \ \ CLEVELAN ��' MECHANICAL ROOM 240 W `- TOTAL: PROPOSED GPI . 4 " 3 4�y \ \ / - ... / 797 ..:... .';,ft .,,.,:y<:k,::. 6.. / \ y .. PARKING REQUIRED (1 PER 1000) 1 Z MECHANICAL AREA + ::Y'j' z' 'ru: ;$ p1 \ CATCH BASIN kTCH _> L j V) W BOLLARD PROTECTION •0 :. _ :.°_ >:.: <,,':::, s,>.,.::t:.:.E: ::.,.,,, Q \ o \ / (SEE DETAIL) 9 0 'L� BASIN �` rY a �f f�� .>< / Pe \ / MEETING HALL NON-PROFIT U Y -J m \ �, `►,�y �j o 3"� Z h s �2 /eAsiNs \o \ / r w MULTI-PURPOSE ROOM 1645 Z Q \ o PROPOSED `.,<..,,.,,..,.,::.. .>.,: .:.: .• ,; 8 x 8 WOOD POST KITCHEN O \ POLE .SILTATION FABRIC INSTALLATION 227 STAIR TOWER PRESSURE TREATED OFFICE o . :` , :<<" ' < ,;.:<:<.=>: ... .> #47e / S 40'29 0 E ( 0 CE (SEE ARCHITECTURAL PLANS) �/ oa M x x �° / \ 1,45 ) AT CATCH BASIN m �O pG x 7 r - x 4. a 4 t 578 [L RECORDS ROOM x 6.44 5/8" CARRIAGE BOLTS NOT TO SCALE 93 PROPOSED �; t CONFERENCE ROOM �- WO c? W Z \ \ 222 Z \ PROPANE TANK LOCATIONS �J ° ' { r, �� �' \ t. TOTAL: 2765 W Z p� \ \ VW/ BOLLARD PROTECTION O� J o' '�j/ �'G� \ \ \ /y PARKING REQUIRED (1 PER 100) 28 a •� c, O ° z 1STIwl:.8t11LD1I1G �, G \ (SEE DETAIL) ��� �� d �f G \ O � QQ`M z GROSS _FL.00R.. ;': O \ M _ MISCELLANEOUS USES ->>� w 0 p Z �+� / ARFJA SUBJECT TO EASEMENT 1- 1/2" CLASS 11 DOT 3 STONE C�! V) 100 P ;:::..;v:,..z:ARF.A*R1600Q V" IT IN " # " ENTRANCE BITUMINOUS CL'OUS CONCRETE Q >x.:::..::;>•<,:>::«:z:..:.::::::..:. , .:;:: :>;>:,>-__:.s:: o AS DESCRIBED IN EASE 10216 3 x 12 DOUGLAS FIR 18 WIDE X 6 DEEP V AT R CL 0 / x 6 96 PAGES 331 33 PR R T ELEV 0 . 2 ESSU E R T EA ED ALONG OUTER EDGE( ) o - 1 1 I 2 BN R � \ POLE ° s / - \ \ / DE COURSE MEN'S TOILET 2) \ PROVIDE 6 FINISHED GRADE WOMEN TOILET 2 _ MOH. SEWER LINE MATCH i' ( ) (n (NOT FOUND 10 _ L , f' \ �� /\/\\/\\/�\�/�\/\\ \/\'< \/\\ \/ GALLERY Z N LIJ T \ INVERT AT EXISTING 8 �/ \/�! / \ //�/ /�r u_ .' SEP TING DISTANCE a=:::<<-<_#;;•.: :::,::. <:.::_ :'A, .; ..:>: 5 \ \/\ �.�/\�\ �\ \ \ \ \ o �- - /\ \'� \ '�/\ � ELEVATOR MA >F:_: ..:.,r, ELEV 0 CHINE ROOM z..,� -:�,.< Q \ SEWER ELEV. 3.75+/ ,/\/\/ i �.• :: \ / / / 0 BUILDING \�� J T N �APPROX. CA 10 \/\ 2 <<3 � JANITOR\'��� \ CLOSET rr p XI TIN WAT R IN H N S G E L PROM 6 HIGH CHAIN E E DE �• LINK EQUIPMENT SERVICE AISLE IN o \ E (INCLUDED N L DED I BOWLING A ( G LLEY x 7.06 <.. POLE FENCE ALIGN ) as>=: \ ti �/ R.R. : r=.c > :::3%:>:v<<;.::>.'«:<:;;>:.:.:: �>-s. <::->' � x 7.36 \#489 a WITH EXISTING FENCE HALLWAYS ( � Q R a.;' �` r�Y:; :'e%?kt %',.ika''.- • ."i ;!:. a:"-_i''ni: �/� \ `_ w / \ 57Ox 7.11 �' SP! f .r '` G�/> \ p ��G�V 12 ROLLED GRAVEL SUBBASE r� �`� 0 PER M.02.02 OF FORM 814A PROVIDE NEW GATE IN FENCE WOOD GUARD RAIL BUILDING SIZE 15984 J NOT T SCALE J� PROPOSED WATER LINE 0 E BITUMINOUS CONCRETE PAVEMENT TOTAL SQUARE FOOTAGE ACCOUNTED FOR FROM ABOVE 1 1610 LNJ SQUARE FOOTAGE REMAINING FOR MISCELLANEOUS USES 4374 G y PROPOSED 1 5/8 O.D. TCOP NOT TO SCALE ATCF1' ��� PROPOSED GRAVEL PARKING AREA RAIL CONTINUOLUS LINE POST TOP / TOTAL PARKING REQUIRED 56 LL / ��- �p CONCRETE STEPS END POST TOP 01y• ^`>° ;_ r MANHOL ` W HANDICAP RAMP .5 A�iG \ E (SEE ARCHITECTURAL PLANS) / � � RAIL END BRACKET BENCHMARK x 7.0 MON. / \ \ \ J 2" O.D. PROVIDED ON SITE PARKING 28 SPACES V V) �' �' RAILROAD SPIKE •(FOUND) / w� \ G,�v N/F LINE POST 4 ROLLED PROCESSED GRAVEL m U � PROVIDED FROM FERRY DISTRICT - 40 SPACES ELEVATION = 7.22 �7 34 �� 3 \ \ UNION FREE TENSION BAND o SCHOOL DISTRICT -/ z \ J TENSION BAR 1 5/8" (O.D. PROVIDE (2) HANDICAP PARKING SPACE(S) DD Z � d ww 0 0 PROPOSED LANDSCAPED AREAS g%/ \ �� WITH NEW BITUMINOUS PAVEMENT dt MI RAt,IL o o < m o 0 (SEE PLA'IT1NG SCHEDULE) / M H // ?�� `� HANDICAP PARKING SIGN(S) ° G 2 1/2" O.D. END OW R�r ° SEWER DESIGN FLOW CALCULATIONS Z °- 0 M.H AND CORNER POSTS o O v = o U U 1 z z � EXISTING LOADING DOCKS �, � d ~ � z Z �� A, I #so �}�`' AND CONC. STEPS TO BE REMOVED (TYP.) \ ,;.. \ \ \ \ COMPACTED GRAVEL SUBBASE PUBLIC GATHERING AREA - 120 x 15 = 1,800 GAL/DAY o o 0 0 � z z �• \\/ '``. '` /� �� /�\/�\� ' 4 BOWLING LANES - 4 x 100 = 400 GAL DAY N w = = Y a M.H x 7.75 PROPOSED GRAVEL SIDEWALK WITH //' / - I+ r GUARD RAIL FOR PEDESTRIAN CONCRETE �/ j\\/ 1 18" O.D. OFFICE AREA - 2 x 12 = 24 GAL DAY a S 40' 19 E FOOTING ' / '` //\/ BOTTOM RAIL GRAVEL SURFACE / � � W w w l o SAFETY SEE DETAIL \ \ \ > V) a x m a a n. PROPOSED / \ bq,n EXISTING UTILITY POLES)LOCATED IN (ALL POSTS) // /�\ I'MaRAN KNUCKLED D BOTTOM NOT TO SCALE SNACK BAR = 20 SEATS x 30 AY GAL/DAY W Lo Lo FENCE W/ SIGNAGE \ \ 0 0 0 0 0 0 0 \\, TOTAL = 2,824 GAL DAY AND BIKE RACK N N N N N PARKING AREA TO BE N N SURROUNDED BY CONC. DOLLARD #359 PROTECTION (TYF'.) TYPICAL CHAIN LUNK FENCING GUY / S 66'53'35' W PROPOSED BIKE RACK NOT TO SCAALE ,� 0 0 4 WIDE PAINTED STRIPING TYPICAL 1.) REFER TO DISCHARGE MONITORING REPORT PREPARED BY DIVERSIFIED z N v rgf I PROVIDE SIGNAGE ' 6" DIA. STEEL PIPE TECHNOLOGY CONSULTANTS - MAY 2006 FOR FISHERS ISLAND SEWER DISTRICT. FILLED SOLID WITH EXISTING STORM DRAINS CURRENTLY MAY BE CONNECTED TO THE SEWER SYSTEM, FOR PEDESTRIAN SJIFETY CONCRETE 36" DRAINS ARE TO BE REDIRECTED TO SUBSURFACE SYSTEMS TO REDUCE INFLOW. (SEE DETAIL) (PAINTED YELLOW) Q 2.) SEWER INFORMATION TAKEN FROM WASTE WATER TREATMENT FACILITIES FOR F- 0 FISHERS ISLAND DEVELOPMENT CORPORATION, NEW YORK. DATE:4/1976. SCAL.E: Q a "=40. SHEET NO. A-2. JC SOMMERS ASSOCIATES INC. 25 TERRACE DRIVE, \ a VERNON, CT. 06066-2416. CONSULTING CIVIL AND SANITARY ENGINEERS & LAIND FINISH GRADE _ SURVEYORS. (0 vi 00 0 D N 3.) ALL DRAIN AND SEWER INVERTS TO BE FIELD VERIFIED AT THE START OF m N I I I N 36" CONSTRUCTION. SECURE TO 1 1/2" 0 GALVANIZED STEEL POST . ' ':. 4.) SITE IS IN THE TOWN OF SOUTHOLD, COUNTY OF SUFFOLK TAX MAP 1000, 0 o HANDICAPPED Ld GALITH VANIZED BOLTS CONCRETE I 4" 0 toSECTION 012, BLOCK 1, LOT 5.1 m U o PARKING (1 TOP, 1 BOTTOM) :•.•r rt. 5.) TOTAL AREA = 1.28f ACRES. DATE; 06/23/2006 ;< STATE PERMIT REOUIRED :,.: :>';. : 2" I 6.) SITE IS LOCATED IN B ZONE. SCALE; 1 " = 30' WILL BE FINED EACH SIGN TO BE QUALITY CONTROL CERTIFICATION SECURED TO 1 1/2" 0 NOTE: SIGN ASSSEMBLY TO BE II F GROUP EVIEWED AT 5'-0" TO GRADE 12" GALVANIZED STEEL POST INSTALLED IN AACCORDANCE WITH WITH (2) 1/4" 0 STATE OF CONINECTICUT D.O.T. PROJECTSURVEY MANAGER v ' GALVANIZED BOLTS STANDARDS HANDICAP PARKING LAYOUT N/F NOW OR FORMERLY HANDICAPPED PARKING SIGN (1 TOP, 1 BOTTOM) SF SQUARE FEET SHEET ENVIRONMENTAL NOT TO SCALE BOLLARD DETAIL Nor To SCALE _PEDESTRIAN SIGN 1 NOT TO SCALE x 7.07 ELEVATION SPOT GRADE 30 15 0 30 2 O F 2 CIVIL �! s STRUCTURAL NOT TO SCALE GRAPHIC SCALE IN FEET ARCHITECTURAL o FENCE FILE 35087 w W i 3 r" E N U 1 t� 'm G N 'C 00 00 CATCH BASIN E �•� a _4-4'x4'x4' DRAINAGE CHAMBERS r�l > � �' 0 0 W Um 0 Z o / '" ��F v o J CATCH pV 3 S f�0� G BASIN ` 7t NM 1 7UHli, U /� '1d30'`1a�g 9`. LO � 4-4'x4'x4' DRAINAGE CHAMBERS 3 N/F TOWN OF cc 00 `::. SOUTHOLD LOCATION MAP SCALE 1 "=400' S 47-53'19* w \ S` N 47'01'19" W �` �u�.?�,'_�',.( �4 P'Icr-e •�>'.",}nor''�>� �O S 63'31 00 E s ,r 7'00 UNION FREE ---- �°` SCHOOL DISTRICT /00-�O-a1'�^ �, w•� - ._- ��`"S,� s � ........_�.. �,,\\\\ 4:i`,.`'0"rr1Cr1.o;I�'.•!a!\%t?0 20 �v/t�a�...t.���r r-..O,Av-J E,..�.�'...:-1=10 IN3JV.i1iVc!_ai7 A.W ,00 S 38.53 APPROX. LOCATION �1 W 6394.72 MAP REFERENCES S 2 10" SEWER LINE N/F I n 0 TO PUMP STATION I� TOD WILLIAMS & POLE #279 1.) WASTE WATER TREATMENT FACILITIES FOR FISHERS ISLAND DEVELOPMENT �j BILLIE TSIEN /� CORPORATION NEW YORK, DATE: 4/1976, SCALE: 1"=40', SHEET NO. A-2, JC Z ' `P . Nlr �\o SOMMERS ASSOCIATES INC. VERNON, CT. w 2�! `, n \\ TOWN OF 3 �o°% \ 2.) SITE PLAN PREPARED FOR FIDCO—BLDG 98; FOX LANE; FISHERS ISLAND, u u , SOUTHOLD NEW YORK; CHANDLER, PALMER & KING; NORWICH, CT.; DATE; FEBRUARY 2, LA SEWER MANHOLE `-1 1993; SCALE: 1"=20'; SHEET 1 OF 1 — GRATED CATCH B;,SIN TOP UTILITY / LANDSCAPED Qe� N 40'15' " Z REPLACED WITH SOLID TOP MANHOLE/ AREAS (TYP.) 0J �p j 20 W ) SITE DEVELOPMENT P 8 11' 3. LAN PREPARED FOR FISHERS ISLAND COMMUNITY uj ELECTRIC 'o, ,2 aPOLE 6" CAST IRON tk �°` / CENTER, INC. FOX 'LANE FISHERS ISLAND, NEW YORK SCALE: 1"=30' DATE: (, Y TRANSFORMER ° I WATER SERVICE �°� y / 06/23/2006 REVISIONS THROUGH No.8 06/06/2007 PER HEALTH DEPT. BY RHS s�� G SHEETS 1 AND 2 t)F 2, BY CME ASSOCIATES ENGiNCERII Lr",ND SURVErNG & �, s" SEWER LINE S 62•>g VALVE �?�G ARCHITECTURE, PLLC. ?�- C.t.. `�,� ?s OQ• 6" CAST IRON / POLE ,,y0 ���� 00. R• WATER SERVICE / #278 0JOf 1500 GAL. GREASE TRAP FOR TO BUILDING / a- 0 Z Z ' FRAMESNS TOT IRON GRADE CATCH BA51N • ��/ D<� L- Z Z 0 INV. OUT=3.01 j �oG 9�p�/ NOTESLd C Q Z \ \ Ld EDGE OF `.� \ s / ���� 0 > Q X Q CATCH N/F PAVEMENTS \ MANHOLE / JELQP 1.) THIS SURVEY WAS PREPARED FOR THE PARTIES AND PURPOSE INDICATED g \ BASIN O• �� HEREON. ANY EXTENSION OF THE USE BEYOND THE PURPOSED AGREED TO w O cn 5-4'x4'x4' DRAINAGE TJS ENTERPRISES, INC. �,� MANHOLE P STAIR TOWER s / / BETWEEN THE CLIENT AND THE SURVEYOR EXCEEDS THE SCOPE OF THE N (� 0 ENGAGEMENT. J \ CHAMBERS p � /Os© '� `<P♦ / p` N F a. w'v\ POLE =. fl F� ellTHOMA.S D. CLEVELAND / 2.) IT IS A VIOLATION OF THE STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED LAND SURVEYOR, TO ALTER AN Z Q y / ITEM IN ANY WAY. '4^ s� / r:,',.:�• a'1� 8" TILE LINEft. O ATCHO '.' x : PLUGGED c, /�� • BASIN "' `' `` .,' 7 {x'; +•� 3.) ONLY COPIES OF THIS SURVEY MARKED WITH THE LAND SURVEYOR'S (n L1_ SIGNATURE AND AN ORIGINAL EMBOSSED OR INK SEAL ARE THE PRODUCT OF j2t,�n Y s2L t `` 'W ''{ - \ YY.7 k��+,°` `. ,:,;�j;�.. `; ,, ,` 'rF` t-f `' 4✓ / THE LAND SURVEYOR, OD*mt STAIR TOWER POLE #478 S 40'291 10» E 4.) COORDINATE DISTANCES CES ARE MEASURED FROM U.S. COAST AND GEODETIC 1,45 SURVEY TRIANGULATION ,:,., 0 STATION "PROS" z �oPoo ��a'�'`'' '; . :: ..;. - ',}: m o� END OF STONE\ W (BURIED PROPANE TANKS o Y � .. Y*N :;��'{^.�4,. t ,;Fc: ,'wai `y5' � \ 5.) SITE IS IN THE TOWN OF SOUTHOLD COUNTY OF SUFFOLK TAX MAP 1000, \ \ W;/ BOULDER PROTECTIONgry '1�'+} ;f- "• ,/� ��, PARKING AREA SECTION 012, BLOCK 1 _) ^ �, z r, ". LOT 5.1 1NG BUIMG f, 6. TOTAL AREA — 1.28f ACRES. \ •,y: EXIS('F. did 't LL Q ll {r, .GROSS:?`'FI OtlR`n:'s' , k AREA SUBJECT 7d EASEMENT ,{ L� _ o t,4ay.' : .;•-au ry r'r' AS DESCRIBED IN LIBER 10216 7,) SITE IS LOCATED IN B ZONE, r � \ O '„.}. .... PAGES 331-332 , `'y kaa ;im ; l 4-4'x4'x4' DRAINAGE POLE $ir. "„ : .l. `( \ "�s'ri`•a�#"''p'vrt r g'p'';��� ,'f7 s% e / �G CHAMBERS 8.) BASE FOR LEVELS: NGVD 1929, ry 0 MON. :?.5F. ° SEWER MANHOLE (NOT FOUND) // T O -. #? s a ';,;; L" "'` ,^ `G+: F '<rT�P� / pt' p� FLOW LINE=4.Ot 9.) PORTIONS OF SITE ARE LOCATED WITHIN AE (10) PER FIRM PANEL 18-1026. z O yr. fl O LLARD , fiarHO � QP ' •(TYP.) t1�•D` 6" SEWER LINE OWNER: Z CHAIN LINK FISHERS ISLAND DEVELOPMENTCORP.� POFENCE WRR. C/O F.I. UTILITY COMPANY a�DRAWER E / \ <57 %jory�a',` � � / // ,aO G �, ,_.. v'" +: �' A // �� FISHERS ISLAND NY 06390 N w o� gw �FpJR CONCRETE PAD fr : �� fl U aI:?::.q .6 ,f �Gt^ .; / 9�� G� LPG WITH HANDICAP PARKING / tfl• „;r _x s,}s; / SPACE, STRIPING AND SIGN to WOOD GUARD RAIL w N IN HANDICAP RAMP N�F- BENCHMARK fl MON. 1 s�� �P�`P GG�G� AND HAND RAIL UNION FREE RAILROAD SPIKE fl (FOUND) / 3 AGc\ \�G �,�.�F`� G / 1f° PF� �,� SCHOOL DISTRICT z ELEVATION == 7.22 \ / \ / LANDSCAPED 61 O` ���� CONCRETE PAD REAS (TYP.) 1 �F� WITH HANDICAP PARKING / 9/ SPACES(2), STRIDING AND SIGN co Q M.H M.H // �k�� 1 p0L • • 6" PVC DISCHARGES DIRECTLY Q 0 m IU ,141' I 490' t FROM CATCH BASIN m U ell GRASS 5-4'x4'x4' DRAINAGE g M.H �' AREA CHAMBERS (0 vj CO ® 10 , \\ °° ao / S 40'43'19" E 1O an o fly ^ I I � ar I N m N _END OF STONE / N PARKING AREA o a 0 -1 11 U z w w LL dlv POLE , 0 O w = 0 w #359 • 0.. m 0 0 U U L� GUY / 1 S 66'53'35" w DATE; 09/30/2008 SCALE: 1 " = 30' m QUALITY CONTROL CERTIFICATION / LEGEN a GROUP REVIEWED PATE \ ° r� PROJECT MANAGER 1?� \ �^ \ N/F NOW OR FORMERLY SURVEY i z \ 30 15 o 30 SHEET SF SQUARE FEET 1 0 F 1 ENVIRONMENTAL CIVIL n RETAINING WALL GRAPHIC SCALE IN FEET STRUCTURAL - o FENCE ARCHITECTURAL 0 c.� W PLUMBING FACILITIES (FIRST FLOOR) ACCESSIBLE ENTRANCES GENERAL NOTES CONSTRUCTION LEGEND FISHERS ISLAND x U MALE 1 PER 125 155/125 = 1.2 2WC 100 MAIN ENTRANCE/FIRE EXIT ACCESSIBLE CONSTRUCTION TYPE to COMMUNITY CENTER Q WATER NEW INTERIOR WALL 13 CLOSETS FEMALE 1 PER 65 155 65 = 2.4 3WC 118 SERVICE DOOR IRE EXIT NOT ACCESSIBLE OCCUPPANCY CLASSIFICATION A-3 / /F NEW EXTERIOR WALL I � MALE 1 PER 200 155/200 = 0.8 1 LAV. 115 SERVICE DOOR/FIRE EXIT NOT ACCESSIBLE FLOOR LOADING 10D PER SF EXISTING WALLS BUILDING 98 = LAVATORIES TO REMAIN FOX LANE ~ FEMALE 1 PER 200 155 200 = 0.8 1 LAV. GROSS AREA OF EXISTING BUILDING FISHERS ISLAND, NY / 2 HR FIRE RATED WALL 0: 1Z FIRST FLOOR GROSS AREA 7334.5 SF UL DESIGN U419 Z DRINKING FOUNTAIN 1 PER 500 2 FOUNTAINS ON 2ND FLOOR MEA 81-98—M, U.Q.N. z SECOND FLOOR GROSS AREA 7334.5 SF W SERVICE SINK 1 SINK REQUIRED 1 SINK ON 1ST FLOOR 1 HR FIRE RATED WALL UL DESIGN TOTAL GROSS AREA 14669 SF to —M, MEA 81-98—M U.O.N. O O ARCHITECT - NEW GALVANIZED STEEL EXTERIOR KINLIN RUTHERFURD ARCHITECTS, PLLC EXIT STAIRS (G.C. TO SUBfvNIT SHOP ` DRAWINGS PRIOR TO FABRI(CATION) 330 WEST 38TH STREET, 10TH FLOOR (TYPICAL FOR 2) (SEE SHT.. A411 FOR \ NEW YORK, NEW YORK 10018 DETAILS) � T 212. 695.2988 7- REQUIRED LOADING DOCK \`� www.kinlinrutherfurd.com REQUIREED AS PER 1 2 04 03 3 4 0z 5 °1 \ SOUTHIOLD TOWN CODE 100-192.A1 ` HVAC/ M.E.P. ENGINEER 7 8 9 10 1 1 12 05 06 13 DESIGN LEARNED, PLLC 0 J O O \ INEW 42" HIGH METAL °' oa 05 j �. 116 MAIN STREET \ NORWICH, CT 06360 EXISTING OPENIN�1@ PERIMETER WALLS 4 , \) ( PROPANE TANK ) PROPANE 1`ANK ) \ \ (RAILING I I FOOD PREP. RECE�SED ELECTRICAL PANELS T 860.889.7078 BE5EALED W/STUCCO FINISH PANELS \ / GkT87S�ON-WIRE-MES1-f fl = ( ) NEW CONC. STEPS y T_ r www.designlearned.com �� 3 MIL BUILDING PAPER ON 3/4" �p 24 r� �I F 4 HAND ASH STAINLESS ;\ PLYWOOD SHEA1fHING ON 2 x 6 WD. I \ I I 1 ' \) \SERVICE DOOR: 6.91 STEEL SINK STRUCTURAL ENGINEER STUDS @ 16" c.c. (TYP. THROUGHOUT \ 36" CLEAR OPENING I U R �_ - -�1-- BOWLING ALLEY') (SEE DTL. 4, SHT. ° I T MECHANICAL A EA �\ OCCUPANTS 6 0„ UMPSTER ° A431) \ � �� �� \ CME ASSOCIATES, INC. I ° 1 1 1) �10) 0Q ❑ (081 \ 333 EAST RIVER DRIVE, SUITE 400 ° � L � - - °' \ ) EAST HARTFORD, CT 06108 - Al STORAGE STORAGE 7-9" d �11;)\10 T 860.290.4100 N _ 24' 1 1 \ www.cmeengineering.com 1 1 2 RATED �� "' ( � \ RADIA BASEBOARD �430, 6 N I O „ „ \: _ SELF C ING DOOR ca�H - 0OD 3 PRE 1 12. HEAT These drawings are instruments of service and 1 -5 µ 9 I 10 0 1 - _ -EL Off_ E' l are protected b copyright._ _ I These designs and - - E R — - P Y9 B ISTI G CONCRETE 5=4" 48" H. DWARF -61SfiANCE. 112 ___COUNTER LOP T E 06 drawings may not be reproduced or copied EX N II SERV. � �, � Io �, �- T� / 9 Y P p PLATFORM (PROVIDE [PARTITION CORIAN Cp �TERTOPS couN� UNTE I w� W I LAB. LAM. �INISH �° CENTER without written permission from (COLOR BY O�JNER/ / Rloo` 1= Z o0 105 C AVORATORY (BY AMERICAN Kinlin Rutherfurd Architects PLLC. ' 107 F 'CE ' _ \I 2DEL ANDARD, CADET SERIES, 42" H. RAILING) [NEW 12" HIGH ARCHITEC _ _ _� �� 11 - _ t �� go \\ �J� FIRE AREA: _# 0419.111 (TYP. C _ -- _ _ _ _ _ _ \ „ _ 1\ „ _ (CON_C__PLATFORM� - _ - "�S 10 11 - �fl�CCU I�fTS L�TOTL€�S) — AMENDMENT SET 02.26.08 16-2 1 -1 SHOWCASE �- I „ - _ U UP 1R (A 3,e o BROOM W I 1 1 2 HR RATED „6 1 REVISED BID SET 12.11.07 107 D I RE ICERPOR� S LF-CLOSING SING DOORS 4 11 gl > - - - @ 1 _ �, _ REF Y 3'-6 - 3'-6 u R o uP 2R SEATING - CAFE �REEZER sw,cK� ° D @ 0 max- -- - - - - - B-0_1 =\. . �� 108 : - �IR� \ _ - - -- - - - S06A -- — - — — — REVISED BID SET 11.07.07 L — J _ O � R� � _ m 02 108 G ' ' - \ 86 OCCUPANTS \W .9'_2"W x 3'-11"d �11 OCCUPANT RE AREA �A\ - (05)�` �00 (10� 0�1 0s REVISED BID SET 10.12.07 „ w 22. 2 I 5'-9:' 5' �1/8.' l.:"� . . WHEEhCHAIR•.L1FT•.(PI�OVIDE•. � •. . . . . a�,,� . . . . . . . . . I •I ' � \ o, I \ --- 2x 10 I-JOISTS @ 16 o.c. 5'-7 1/8"w'x 5'-0 1/2"d x 1 DEEP 1 8'-4' REVISED BID SET 09.27.07 :R D - „ - �EVATOR�T WPEI� \E SERVICE DOOR. -� _ \-� I I 'I I �, ; _ \ ,,, TRAVEL DISTANCE: 142 o ELEV. J �" ANUFACTUhER S SPECS) - \-- -- CHILDREN S REVISED BID SET 07.25.07 os 273 OCCUPA CLEAR ONTSING w } iI hv1ACHINE �I II TANK 101),9" ) ,-� --- 104) 4 , ' , I � � : : 'I' os `r I po ER },F'°' o (SEE STRUCTURAL DRWGS.) \ \ Y\ _i „ REVISED BID SET 05.31.07 CENTER 3 . . . . . . . . I I t G� MEN S 00 104 c 1 r f C t [ROOM 1 1 — --� -�� -�,. ) Q FICE 1 x 3 q, y", NI: ILET �� 05� \NEW CONC. STEPS _ _ - - - - - �_ - - x - _ T \_ \ - �� REVISED BID SET 05.11.07 T i 3: i 1 - n 0— PROVIDE 42 H. -- - _ I -- 6CD ( �— � - - — I I ENTRANCE �I �-- Y WOMEN L - REVISED BID SET 0 IL RAILING) �`\�� I 1�Oj � J.C. I 9R� .97 I 100 D 17-9 - OILET �b��� a 5 4.19.07 N STORAGE STORAGE 11 o I- *� O i m 02 B REVISED BID SET 04.06.07 c'V -- _- - — — I - REVISED BID SET 02.13.07 \\ � 04� 5" \\ RAMP UP �o - 1001 01 ram\ BID SET 10.20.06 BOWL NG LANES TO SIT ON NEW > = vo ,\ CRIB FOUNDATION (MDF UNDERLAYMENT M�I %� 9 -0 _ 72' CLEAR OPENING @ 6. FLOOR ANHORED TOILET PARTITION ON (2) LAYERS OF PLYWOOD SPACERS NEW STAIR. (SEE STRUCTURAL DRA INGS) T AVEL DISTANCE: 84-0 I W/PHENOLIC FINISH (BY GLOBAL OR DESIGN DEVELOPMENT 10.10.06 a, \ — \ 240 OCCUPANTS APPROVEDI EQUAL) (TYP.) �\ 2 x 10 WOOD I-JOISTS @ 16" o.c. ON (G.C. TO PROVIDE SHOP LEVELING WEDGES DRAWINGS PRIOR TO FABRICATION) SUBMISSION SET 09.01.06 (SEE DETAILS) (PROVIDE METAL HANDRAIL AS RE(�'D) NOTE: WHERE APPLICABLE, INFILL SHALL BE DESIGN DEVELOPMENTSET 03.22.06 °� CONSTRUCTED OF 3-COATS STUCCO os oe (OUTSIDE) ON 3/4" EXTERIOR-GRADE REVISED W/ AC SCHEMATIC 02.01.06 NEW CONCRETE STEPS, PLATFORM PLYWOOD ON 2 x 6 WOOD STUDS @ MOP SERVICE BASIN & RAMP (PROVIDE 42" HIGH METAL 16" O.C. W/R-11 INSULATION BETWEEN DESIGN DEVELOPMENT SET 01.10.06 (24"x36") RAILING) (SEE DTL. 1 & 7, SHT. A435) STUDS & (1) LAYER 5/8" GYP. BD. (INSIDE) (TYP.) \ PRELIMINARY BID SET 12.07.05 DESIGN DEVELOPMENT 11.16.05 l� REVISION DISCRIPTION DATE STAMP: to QJ ap �� 0 01 CONSTRUCTION PLAN: FIRST FLOOR 1/8,= V-0„ �9 029c!i6 UP NSW ROOM FINISH SCHEDULE OCCUPANCW CALCULATIONS (FIRST FLOOR) — ASSEMBLY/A3 CLASSIFICATION ROOM # [ROOM NAME OCCUPANCY FLOOR AREA IN SQ.FT. FLOOR. AREA # OF OCCUPANTS FINISH PER OCCUPANT TYPE FLOOR BASE WALLS WAINSCOT CEILING REMARKS A CARPET WOOD GYP. BD. PAINTED 1080 BOWLING BOWLING CENTERS 5 PER LANE 4 LANES 20 OCC. PROJECT #: B CERAMIC TILE CER. TILE GYP. BD. PAINTED CER. TILE 48" H A.C.T. 108b SEATING ASSEMBLY (UNCONCENTRATED) 15 NET 490 SF 33 OCC. DRAWN: CHECKED: C CARPET WOOD GYP. BD. PAINTED A.C.T. 107b (CAFE ASSEMBLY (UNCONCENTRATED) 15 NET 427 SF 29 OCC. SCALE: D VCT RUBBER GYP. BD. PAINTED 107a SERVICE COUNTER KITCHENS, COMMERCIAL 200 GROSS 191 SF 1 OCC. PRINT DATE: N E GYP. BD. PAINTED IN r 106 FOOD PREP. KITCHENS, COMMERCIAL 200 GROSS 133 SF 1 OCC. SHEET TITLE: x F VCT RUBBER GYP. BD. PAINTED A.C.T. N G WOOD WOOD GYP. BD. PAINTED A.C.T. 105 -TEEN CENTER ASSEMBLY (UNCONCENTRATED) 15 NET 735 SF 49 OCC. FIRST FLOOR " CONSTRUCTION PLAN N H WOOD WOOD GYP. BD. PAINTED 104 (CHILDREN'S CENTER ASSEMBLY (UNCONCENTRATED) 15 NET 313 SF 21 OCC. W I VCT RUBBER GYP. BD. PAINTED GYP. BD. PAINTED 101 (OFFICE 1 BUSINESS AREAS 100 GROSS 165 SF 2 OCC. W x i TOTAL OCCUPANTS (FIRST FLOOR) 1 57 OCC. SHEET NUMBER: A101 o ;F � PLUMBING FACILITIES (SECOND FLOOR) GENERAL NOTES CONSTRUCTION LEGEND FISHERS ISLAND x MALE 1 PER 125 162/125 = 1.3 2WC CONSTRUCTION TYPE 1A COM M U LAITY CENTER Q WATER r-:�-� NEW INTERIOR WALL In CLOSETS FEMALE 1 PER 65 2.5 3WC 65 162 = OCCUPPANCY CLASSIFICATION A-3 / NEW EXTERIOR WALL w MALE 1 PER 200 162/200 = D.8 1 LAV. FLOOR LOADING 100 PER SF EXISTING WALLS BUILDING 98 x LAVATORIES TO REMAIN FOX LANE FEMALE 1 PER 200 162/200 = D.8 1 LAV. GROSS AREA OF EXISTING BUILDING FISHERS ISLAND, NY x 2 HR FIRE RATED WALL Z FIRST FLOOR GROSS AREA 7334.5 SF UL DESIGN U419 DRINKING FOUNTAIN 1 PER 500 2 FOUNTAINS ON 2ND FLOOR MEA 81-98-M, U.O.N. Z SECOND FLOOR GROSS AREA 7334.5 SF Y —————— 1 HR FIRE RATED WALL SERVICE SINK 1 SINK REQUIRED 1 SINK ON 1ST FLOOR TOTAL GROSS AREA 14669 SF UL DESIGN U419 0o MEA 81-98-M, U.O.N. ARCHITECT KINLIN RUTHERFURD ARCHITECTS, PLLC 330 WEST 38TH STREET, 10TH FLOOR NEW YORK, NEW YORK 10018 T 212. 695.2988 www.kinlinrutherfurd.com 1 2 3 4 O 6 7 8 9 10 11 12 13 HVAC/ M.E.P. ENGINEER 04 03 02 01 o, D6 DESIGN LEARNED, PLLC 21 , 21 21 �03 A21 oe 1 1/2 HR RATED SELFCLOSING DOOR ' 116 MAIN STREET 42 CLEAR OPENING NORWICH, CT 06360 140 OCCUPANTS T 860.889.7078 1 1/2 HR RATED SELF C OSING DOOR L 42" CLEAR OPENING z FTTT]s NEW TAB-TENSIONED MOTORIZE www.designlearned.com r l - CLIMATE PANELS WITH 140 OCCUPANTS I�� 1 1 1/2 HR RATED SELF CLOSING D OR 6'-4"H x 11'-8"W PROJECTION RAD�ANT HEAT SYSTEM \c I 1 �\ FLOOR ANCHOR D TOILET PARTITION �1 \\ 280 OCCUPANTS OPENING I SCREEN (BY DRAPER, MODEL STRUCTURAL ENGINEER UN ER OAK FLOORING \ W/PHENOLIC FIN SH (BY GLOBAL OR 36" REFRIGERATOR - ACCESS/SERIES V OR APPROVED DN APPROVED E( U L TYP. J _ \� \ ) ( ) �- n DN EQUAL) CME ASSOCIATES, INC. �331 32) \311 i 30 1 II \ �27) 2�6, 2 210' 24� 23? �. / _ J' (v 1 _ _ -i 29) \ 28.' J' 333 EAST RIVER DRIVE, SUITE 400 In- __ --- ---- - _ ICI O — �, I FT y, „ 1DFTR A R A R A R A R-A R B — - - FTR- F R A �R A 11`. I \� -1 1 I MECHANICAL I I -- Ij ' R-A FTR-A 5 I � � I I � T 860.290.4100 25'bl u d.. -0" 5'-0" - �'-o" 3/4 HR ATED } - '-0" 7'-0' www.cmeengineering.com -o" 5'- li — - . . . .9 A30Z 11N P P e IP SELF'CLD INC DOOR' 1 P 1 EXHAUST FAN Om 1 _ + A3� 3>? ti _ � ,2 15—0 � ,--,-1 1/2 HR RATED SELF CLOS � DOOR /;��O RAT�D SELF CLOSING DOOR I 4'-6' I 4� A431 51 E I MCH. RM � EN / _ IThese drawings are instruments of service and 34� o �, I 208E r �,�. OILETOFFICE 2 � _ are protected by copyright. These designs and TUDI `; I II I I \. - 205 C A43,E 14,_9„ 8-9 drawings may not be reproduced or copied A431B I �, `r E 206 without written permission from i _ 09 H 7-s`I WOMP'7, �� VISPLIT LEVEL I i TpRA EI 2 207 Klnlln Rutherfurd Architects PLLC. B - - - - } - � � - { \- - - \ \ WATEC��#� �� �HBi�VE �I� i � - - - - - \� _ - - - T BY OASI OR 07 B (21 / 21 / �7 SEL EXISTING PENING D+ J ( I I I DRESSIN d y .� II D, AMENDMENT SET 02.26.08 A43, APPROVED - - I 215 B - I I INL�OR (SEE , FIT ESS A431D I h i 08 STRUCTURAL DRA INGS u - - J ) REVISED BID SET 12.11.07 ART-SAC - - - _ -r \ J _ 77 _ — — - _ ORA�T9R AM _- .6OC T - „ I _ REVISED BID SET 11.07.07 A - T (2T& I I \ — �TANDA�RD, CADET SERt1 S; 9 - J �� A437C SEAL:EXISTING PE�11NG LL CRAFTS I� T �I 02 `_� EL p41 J il1) (T•YP. D UBLE BOWL STAINLESS � REVISED BID SET 10.12.07 TR VEL DISTANCE: 172-0 J` { yet OR' (SEE �.O , „ 5, ; - - I -/rye, - ' " 20Q A • LLrT01LE•T �. .5.-6. ,,. / 202 F �. ^ T L SINK ST UCTURAL DRA INGS T� l D, - L-t-- ---- 50' 2" _ _ _.._... __....__ � - _ REVISED BID SET 09.27.07 LLIWK( u`\" ".: N CD _- J \! 20 I 221 :::: \: : .24 : PR 201� "> _ 2 71 J 14-s" LAN .. .. .... . REVISED BID SET 07.25.07 oz q T.- - O — n CU �IES ► 17 7" 7'-6" 18„- DN �rAOER o - -� - MULTI- PURPOSE POSE D2 �, _I I CONFERENCE. :. .:.: ... CAT RING �i RAVEL 13 36 VIL AGE RECORDS I IW I I I 203 ��ITANCE: 18�-0" ��I REVISED BID SET 05.31.07 R _� � 1 1/ HR RAT D SELF CLOSIN DOOR* ' �- _ _ .- 2 w C19> REVISED BID SET 05.11.07 NG �� OFIFICE (2221 ROOM 2 3, . .. . C�OM:. : ::: PANTRY STOR EE 1 � i N 1 1 III I � 17-5 _ � � � � � � I,'I� 213 C 2114 C ' - I �-- 4 F5 A3010 3 L I �.. 91RE AR 9 OCC E'ANTS FTR-B FITR+A FTR-A I f - FT -A FTR-A FTR-A I' I Ln FTR-A FT -A R-A - R-A �F -A 14RiA FTR-B REVISED BID SET 04.19.07 FTR-A FT -A „ „ „ 23 5, 0„ 5'-0" F 1 5,-0" FTR-A 5'-0„ 5, 0„ 0„ 4 O6J 5-0 i 5'- 5' 5 -0 I 5'-0" 5'-0" 5 -0 5'r0" 5'- 7'-0" -LL � � REVISED BID SET 04 06 07 /� �� \/ /� 18'> REVISED BID SET 02.13.07 �f 38> 42 43,, 1144' 5, � (17 1 1/2 HR RATED SELF CLOSING DOOR COUNTERTOPS W/ BID SET 10.20.06 PLASTIC LAMINATE 3/4 HR RATED SELF CLOSING DOOR A2; A2; 2; 50" CLEAR OPENING FINISH (COLOR BY DESIGN DEVELOPMENT 10.10.06 04 03 02 01 250 OCCUPANTS OWNER) I SUBMISSION SET 09.01.06 ALL PURPOSE/PLASTER WORK SINK BY AMERICAN ( DESIGN DEVELOPMENT SET 05.11.06 STANDARD, MODEL #9061.193) (PROVIDE PLASTER- \� DESIGN DEVELOPMENT SET 03.22.06 INTERCEPTOR TRAP) \ REVISED W/ AC SCHEMATIC 02.01.06 DESIGN DEVELOPMENT SET 01.10.06 PRELIMINARY BID SET 12.07.05 I DESIGN DEVELOPMENT 11.16.05 01 CONSTRUCTION PLAN: SECOND FLOOR 1/8" = V-0" REVISION DISCRIPTION DATE STAMP: ,`�FiED 7V f�L,y ROOM FINISH SCHEDULE OCCUPANCY CALCULATIONS (SECOND FLOOR) - ASSEMBLY/A3 CLASSIFICATION ROOM # ROOM1 NAME OCCUPANCY FLOOR AREA IN SQ.FT. FLOOR AREA # OF OCCUPANTS `` TYPIEFINIISH FLOOR BASE WALLS WAINSCOT CEILING REMARKS PER OCCUPANT 9jFo 29AZA' F NE A CARPET WOOD GYP. BD. PAINTED 202 ARTS; & CRAFTS EDUCATIONAL/SHOPS 50 NET 502 SF 10 OCC. 14 B CERAMIC TILE CER. TILE GYP. BD. PAINTED CER. TILE 48" H A.C.T. 203 LARGE MULTI-PURPOSE ASSEMBLY (UNCONCENTRATED) 15 NET 1480 SF 99 OCC. C CARPET WOOD GYP. BD. PAINTED A.C.T. 204 CATERING PANTRY KITCHENS, COMMERCIAL 200 GROSS 258 SF 2 OCC. p VCT RUBBER GYP. BD. PAINTED 205 OFFICE 2 BUSINESS AREAS 100 GROSS 191 SF 2 OCC. PROJECT #: E GYP. BD. PAINTED F VCT RUBBER GYP. BD. PAINTED A.C.T. 208 MECHANICAL ROOM ACCESSORY STORAGE AREAS 300 GROSS 241 SF 1 OCC. DRAWN: 209 DANCE STUDIO EXERCISE ROOMS 50 GROSS 654 SF 13 OCC. CHECKED: G WOOD WOOD GYP. BD. PAINTED A.C.T. SCALE: H WOOD WOOD GYP. BD. PAINTED 210 FITNESS ROOM EXERCISE ROOMS 50 GROSS 1385 SF 28 OCC. PRINT DATE: VCT RUBBER GYP. BD. PAINTED GYP. BD. PAINTED 211 STORAGE ACCESSORY STORAGE AREAS 300 GROSS 196 SF 1 OCC. SHEET TITLE: N � x 212 VILLAGE OFFICE BUSINESS AREAS 100 GROSS 210 SF 2 OCC. SECOND FLOOR 04 N 213 RECO)RDS ROOM BUSINESS AREAS 100 GROSS 89 SF 1 OCC. CONSTRUCTION PLAN W 214 CONFERENCE ROOM BUSINESS AREAS 100 GROSS 215 SF 3 OCC. W x J TOTAL OCCUPANTS (SECOND FLOOR) 162 OCC. Q SHEET NUMBER: Z A102 t7 O