Loading...
HomeMy WebLinkAbout33047-Z FORM NO. 4 TOWN OF SOUTHOLD BUILDING DEPARTMENT Office of the Building Inspector Town%Hal Southold, N.Y. CERTIFICATE OF OCCUPANCY No: Z-33729 Date: 05/22/09 THIS CERTIFIES that the building ADDITIONS/ALTERATIONS Location of Property: 145 MEDAY AVE MATTITUCK (HOUSE NO. ) ' (STREET) (HAMLET) County Tax Map No_ 473889 Section 113 Block 8 Lot 10 Subdivision Filed Map No. Lot No. conforms substantially to the Application for Building-Permit heretofore filed in this office dated MAY 71 2007 pursuant to which. Building Permit No. 33047-Z dated MAY 21, .2007 was issued,' and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is "AS BUILT" ALTERATIONS AND ADDITIONS, INCLUDING FIRST AND SECOND FLOOR DECKS, TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR. The certificate is issued to KIM AZZARELLI & MATTIA FILIACI (OWNER) of the aforesaid,building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL N/A ELECTRICAL CERTIFICATE. NO..' 3047845 12/18J07 PLUMBERS CERTIFICATION DATED 05/05/09 MATTITUCK PLUMBING J , A, horized Signature Rev. 1/81 r Form No 6. I TOWN OF SOUTHOLD BUILDING:DEPARTMENT .�� �j TOWN MALL` D 765-1802 MAY 1. ,2009 APPLICATION FOR.CERTIFICATE OF OCCUP This.application:must be filled in.by typewriter or ink and submitted to the Building D partment ing: . TdtRi� A. For new building or new use: ` . Final survey of property with accurate location of all buildings,property lines;streets,-and unusual natural or . topographic features.. i e Final Approval-from Health Dept of water:,supplyand sewerage-&posal:(S-9 form).. Approval of electrical installation from Board of Fire Underwriters.- Sworn statement from plumber certifying'-that the solder used in system contains less than 2/10-of 1%a.lead. CommerciaY building,industrial building;-multiple residences and similar buildings and installations,.a certificate of Code Compliance.from architect or.engineer responsible for the building. 'k Submit.Planning Board Approval of completed site plan requirements: B.. For existing.buildings'(prior to Apo.%1957)non.conforming.uses,or buildings and"pre-existing"land.uses " l.. .;Accurate'survey of property showing all property.lines,streets,:building and unusual natural or topographic features. " j. 2. "A properly completed•application and consent to inspect signed by the applicant.If a Certificate:of Occupancy is denied;the Building In shall:state the reasons therefor in writing.to the applicant. C. Fees L Certificate:of Occupancy'-New dwelling$25.00,Additions to dwelling$25.00,Alterations to dwelling$25:00, Swimming pool$25.00 Accessory building$25.00,AAdditions to accessorybuilding$25.00,Businesses$50.00. 2: Certificate of Occupancy.on Pre-existing Building.- $100.00 3. Copy.of Certificate of Occupancy-$.25 . 4: Updated Certificate of Occupancy $,50-.00 5.. Temporary Certif cate of.Occupancy-Residential$15.00,Commercial$15.00 Dater �. J" Al t Ole\ New..Construction: .: Old or Pre-existing Building: :(cheek one p - Location`of Property: t' �,Z.c�d.� Gi:UI House No. Str t Hamlet. Owner or Owners.of Property: Ll 73. �y Suffolk County Tax Map'No 1�00,.Section. 11. '�" Block 006 5 Lot 010 • Subdivision Filed Map. . Lot: Permit No. 31b ql ;n Date of Permit. 6` Applicant: Health Dept:Approval: Underwriters Approval: Planning"Board Approval: Request.for: Temporary Certificate Final.Certificate:_ (check one) Fee Subm�:tted:$ C) Leo �3 7a j 7 (. Applicant Signature rJ�GI[J�[1[1'[1�rJ&1�cP[17[J�[J�[l�G�[.I�GI�[�[P[1�rJ[f[1[J�[!C1�G1�[J�[PLrL[1[J�[J�[1�[1rJ�[.l[n[J�[J�[PrJ�[1�[1rJ[1�[![1�[1�r�[J@1�[J�[J�[J�[J�r�cPLrL3PL c.PrJ7 0 5 BY THIS CERTIFICATE OF COMPLIANCE THE S 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 S 5 BUREAU OF ELECTRICITY 5 5 40 FULTON STREET - NEW YORK, NY 10038 5 . CERTIFIES THAT 5 5 c5 5 Upon the application of upon premises owned by 5 5 5 5 Q.C. ELECTRIC, INC. MR. AZZARELLI 5 PO BOX 518 145 MEDAY AVE c� 5 LAUREL, NY 11948-051.8, MATTITUCK, NY 11952 5 c5 5 Located at 145 MEDAY AVE MATTITUCK, NY 11952 5 5 5 5 Application Number: 3047845 Certificate Number: 3047845 5 5 5 Section: Block: Lot: Building Permit: 33047 BDC: ns11 S 5 5 5 Described as a occupancy, wherein the premises electrical system consisting of 5 5 electrical devices and wiring, described below, located in/on the premises at: 5 Basement,First Floor,Second Floor,Outside, 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed rj 5 herein, was conducted in accordance with the requirements of the applicable . code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the 18th Day of December;2007. 5 Name QTY Rate Rating Circuit Tyne 5 5 Appliances and Accessories 5 5 Dish Washer 1 0 1.2 KW 5 Oven 1 0 5.2 KW SExhaust Fan 3 0 F.H.P. S 5 Hydro Massage Tub(Therapeutic) 1 0 5 5 Wiring and Devices 5 5 Outlet 47 0 Fixture 5 5 Outlet 47 0 Incandescent �� 5 Outlet 59 0 General Purpose 5 5 Receptacle 32 0 General Purpose S 5 Switch 24 0 General Purpose 5 5 Dimmers 9 0 S 5 Paddle Fan 1 0 5 5 Receptacle 1 0 20a Laundry 5 5 Receptacle 1 0 30a Dryer 5 5 Receptacle 9 0 GFCI 5 5 seal 5 5S 1 of 1 = 5 5 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 111 amiul �����������������LPL������MPL�LpC������������������nRLPL����� o C E V E _ SUFFo14,cOG MAY 1 4 2009 o W = To-n Hall, 53095 Main Road O BLDG.DEPT. y,�o ��`� TOWN OF SOUTHOFax (631) 76 •950' P.O. Box 1179 ". 65�15G� Jo ho!�. .Ne"- York 11§71.0959 '� d t -�' BUILDING*DEPARTMENT TOWN OF SOUTHOLD CERTIFICAT10 N Dater O 9 Building Permit No. 3 3o cIZ Owner: 14-11M A-LZAAEl—L1 (Please,pfint) Plumber: MATTITUCK PLUMBING; Mattituck, W 11952 %1 298-8393/Fax: 631-298-1130 1 certify that the solder used in the water supply system contains less than 2/10 of 1% lead. (Plumbers Signature) Sworn to before me this dad- of '�(l y 20 O =SEKINGE KING tate of New York 01 K16041757uffolk countypires May 15,2!:►� r - Notary Publi C0unty Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck,New York 11952 Fax 631-298-2651 www.condonengineering.com May 19, 2009 e Michael Verity-Chief Building Inspector Building Department Southold Town Hall 53095 Route 25 P.O. Box 1179 Southold, New York 11971 RE: Filiaci Residence-145 Meday Avenue, Mattituck, New York SCTM#1000-113-8-10 Dear Mr. Verity: An inspection was made of the Filaci residence at 145 Meday Avenue, Mattituck, New York in May 2009. Based on our observations and to the best of my knowledge, the building conforms to the New York State Building code with the following exceptions: Our office prepared a revised set of design drawings for the new building dated May 13, 2009, which indicates the required improvements needed to bring the building and decks into compliance with the NYS Building Code. If you have any questions please call at 298-1986. Yours truly, Condon, P.E. FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 33047 Z Date MAY 21, 2007 Permission is hereby granted to: KIM AZZARELLI & ANO 145 MEDAY AVE MATTITUCK,NY 11952 for AS BUILT ADDITIONS AND ALTERATIONS TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 145 MEDAY AVE MATTITUCK County Tax Map No. 473889 Section 113 Block 0008 Lot No. 010 pursuant to application dated MAY 7, 2007 and approved b Building Inspector to expire on NOVEMBER , Fee $ 860 . 80 Authorize S 'g ture ORIGINAL Rev. 5/8/02 G4c"—'765.1802 1 BUILDING DEFT. INSPECTION [ ] FOUNDATION iST [ ] ROUGH PLBG. I [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION REMARKS: DATE `��� D Z ANSPECTOR�6 ���!� ho�apF SOUTy�Io 0Lfr7p # # 00UNT1,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1602 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING D�FINAL A [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE _ O INSPECTOR �o�a0f SOUlyo�o 7 , cOUMV,Nc� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION / 1 REMARKS: r 0-1- J ��`- - u"A f DATE 11 - INSPECTOR -a;7 DFSo oOUNi`I TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] RO H PL13G. [ ] FOUNDATION 2ND [ INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: r DATE // INSPECTOR OF SOUj�olo cOUM`1,Na TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST P \ ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ FRAMING STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARK : �� s VL C/ tv "O�ooj DATE INSPECTOR rl �pF so . o Comm • ao TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLOG. [ ] F UNDATION 2ND [ ] INSULATION [V FRAMIN / STRAPPING [ ] ,FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: ���5 DATE j INSPECTOR _ pf SO�lyo�o 3,,,3, o if 7 :0— cou TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [Xf FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: krL- DATE INSPECTOR c pF SO!/ryOlo -3 7r . courm,��'a TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION] FOUNDATION 1 ST [ ] ROUGH PLBG. [ \] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR �i�� FIELD INSPECTION REPORT DATE I COMMENTS t j C)_ro FOUNDATION(1ST) �y ------------------------------------- FOUNDATION(2ND) z CA o T n � H r ROUGH FRANIING& PLUMBINGvL .r- �,9:0A, OL C� x INSULATION PER N.Y. STATE ENERGY CODE o o m� � o FINAL - ADDITIONAL COMMENTS l �; C r Lg s Z cT- ' co �z r� . ro �3 TOWN OF-SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631)765-9502 Survey www.northfork.neVSouthold/ PERMIT NO. �36��� Check Septic Form N.Y.S.D.E.C. Trustees Examined / 20_ _ Contact: Approved 20 Mail to: Disapproved a/c Phone: 19 V0 Expiration ,20 - InS APPLICATION FOR BUILDING PERMIT Date 2007 �' -- INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspect7*ii ant or name,if a corporation) ko*P , (Mailing address of applicant) State whether applicant is owner,lessee,agent,architect,engineer,general contractor, electrician,plumber or builder Name of owner of premises i t'Y1 1�;L 1A41I (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: /_il5' &EMA t1 �4✓ ,vt>a' /� 7Yi7tJG� House Number Street Hamlet County Tax Map No. 1000 Section //3 Block 1� Lot /O Subdivision Filed Map No. Lot (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy P�5 i�gNG� b. Intended use and occupancy 3. Nature of work(check which applicable):New Building Addition (/ Alteration Repair Removal Demolition Other Work /V4rw (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling,number of dwelling units ,/ Number of dwelling units on each floor / If garage, number of cars d�,d 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. �oVA 7. Dimensions of existing structures,if any: Front 2,4. Rear 2 .9- Depth 20- �5 Height /'7 Number of Stories l Dimensions of same structure with alterations or additions: Front Rear Depth_ o.,V Height 25 Number of Stories 2- 8. Dimensions of entire new construction:Front 241•G' Rear �'?� Depth 20,s Height 7 6"' Number of Stories 2 9. Size of lot:Front `Gt� / Rear / Depth 2./5'�� 10.Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law,ordinance or regulation?YES NO-Y-1- 13. Will lot be re-graded?YES NO Y Will excess fill be removed from premises?YES NO � 41l 6457 63 5i Ae%'1 Zg 14.Names of O e f premises k'm r-j uAdI Address N&ivy /co22- Phone No. 4Z7-&O-202G- Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey,to scale,with accurate foundation plan and distances to property lines. 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF ) being duly swom,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, (S)He is the "tiE-/2 (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and'is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of 20_p__7 Notary Public tore of Applicant mww Nfty Publci,state York p N0.OIC05017852 com tsion Evoms Sept Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheckSoftware Version 3.5 Release lc Data filename: C:\AutoCadDrawings\Filiaci\Energy Calc..rck TITLE:Filiaci Residence COUNTY: Suffolk STATE:New York HDD: 5750 CONSTRUCTION TYPE:Detached 1 or 2 Family HEATING TYPE:Non-Electric DATE:05/05/07 DATE OF PLANS:May 4,2007 COMPANY INFORMATION: Condon Engineering 1755 Sigsbee Road Mattituck,New York 631-298-1986 COMPLIANCE:Passes Maximum UA=372 Your Home UA=363 2.4%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1:Cathedral Ceiling(no attic) 480 30.0 0.0 16 Ceiling 2:Flat Ceiling or Scissor Truss 321 30.0 0.0 11 Ceiling 3:Cathedral Ceiling(no attic) 161 30.0 0.0 5 Skylight 1:Wood Frame:Double Pane with Low-E 8 0.450 4 Ceiling 4:Flat Ceiling or Scissor Truss 160 30.0 0.0 6 Wall 1:Wood Frame, 16"o.c. 220 21.0 0.0 10 Window 1:Wood Frame:Double Pane with Low-E 36 0.350 13 Wall 2: Wood Frame, 16"o.c. 220 21.0 0.0 5 Window 2:Wood Frame:Double Pane with Low-E 126 0.350 44 Wall 3:Wood Frame, 16"o.c. 290 21.0 0.0 13 Window 3:Wood Frame:Double Pane with Low-E 69 0.350 24 Wall 4:Wood Frame, 16" o.c. 280 15.0 0.0 17 Window 4:Wood Frame:Double Pane with Low-E 42 0.350 15 Door 2: Solid 21 0.600 13 Wall 5: Wood Frame, 16"o.c. 160 15.0 0.0 10 Window 5:Wood Frame:Double Pane with Low-E 36 0.350 13 Wall 6:Wood Frame, 16"o.c. 256 15.0 0.0 16 Window 6:Wood Frame:Double Pane with Low-E 43 0.350 15 Wall 7:Wood Frame, 16"o.c. 20 21.0 0.0 1 Wall 8+Wood Frame, 16"o.c. 192 21.0 0.0 10 Window 7:Wood Frame:Double Pane with Low-E 24 0.350 8 Wall 9:Wood Frame, 16" o.c. 80 21.0 0.0 4 Window 8:Wood Frame:Double Pane with Low-E 9 0.350 3 Wall 10:Wood Frame, 16"o.c. 110 21.0 0.0 6 Window 9:Wood Frame:Double Pane with Low-E 9 0.350 3 Wall 11:Wood Frame, 16"o.c. 192 21.0 0.0 8 Window 10:Wood Frame:Double Pane with Low-E 24 0.350 8 Door 1:Solid 21 0.600 13 Wall 12:Wood Frame, 16"o.c. 81 21.0 0.0 4 Window 11:Wood Frame:Double Pane with Low-E 9 0.350 3 Wall 13:Wood Frame, 16"o.c. 156 21.0 0.0 9 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 990 30.0 0.0 33 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and signed this page, ey are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications in mpliance with this Code. Builder Date REScheck Inspection Checklist New York State Energy Conservation Construction Code -------RE�checkS-oflwue-Version-3-.5Reie DATE: 05/05/07 TITLE:Filiaci Residence Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1:Cathedral Ceiling(no attic),R-30.0 cavity insulation Comments: [ ] 2. Ceiling 2:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: [ ] 3. Ceiling 3: Cathedral Ceiling(no attic),R-30.0 cavity insulation Comments: [ ] 4. Ceiling 4:Flat Ceiling or Scissor Truss,R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1:Wood Frame, 16"o.c.,R 21.0 cavity insulation Comments: [ ] 2. Wall 2:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 3. Wall 3:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 4. Wall 4:Wood Frame, 16"o.c.,R-15.0 cavity insulation Comments: [ ] 5. Wall 5:Wood Frame, 16"o.c.,R 15.0 cavity insulation Comments: [ ] 6. Wall 6:Wood Frame, 16"o.c.,R-15.0 cavity insulation Comments: [ ] 7. Wall 7:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 8. Wall 8:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 9. Wall 9:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 10. Wall 10: Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 11. Wall 11:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 12. Wall 12:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: [ ] 13. Wall 13:Wood Frame, 16"o.c.,R-21.0 cavity insulation Comments: Windows: [ ] 1. Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 2. Window 2:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: . [ ] 3. Window 3:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 4. Window 4:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes [ ]No Comments: [ ] 5. Window 5:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 6. Window 6:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 7. Window 7:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 8. Window 8:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: [ ] 9. Window 9:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: [ ] 10. Window 10:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: [ ] 11. Window 11:Wood Frame:Double Pane with Low-E,U-factor:0.350 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? [ ]Yes[ ]No Comments: Skylights: [ ] 1. Skylight 1:Wood Frame:Double Pane with Low-E,U-factor:0.450 For skylights without labeled U-factors,describe features: #Panes Frame Type Thermal Break?[ ]Yes[ ]No Comments: Doors: [ ] 1. Door 2:Solid,U-factor:0.600 Comments: [ ] 2. Door 1: Solid,U-factor:0.600 Comments: Floors: [ ] 1. Floor 1:All-Wood Joist/Truss:Over Unconditioned Space,R-30.0 cavity insulation Comments: Air Leakage: [ ] Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be nistalled with a 3"clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-4. [ ] Supply ducts in unconditioned spaces must be insulated to R-8. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R-2. Insulation is not required on return ducts in basements. Duct Construction: [ ] I All joints,seams,and connections must be securely fastened with welds,gaskets,mastics (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. Exception:Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] J Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State ,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the levels in Table 2. Table g: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1„ Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2"Runouts 1"and Less 1.25"to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) TOWN OF SO UMOLD PROPERTY RECORD CARD SUB. 7, LOT. VILLAGE DIST. T7;p�6, - -- STR7EET Y -- "77 OWNER CA:+ E A C R. FORMER OWNER N ... ... ir W TYPE OF BUILDING S W V)4- alk v VL. FARM comm. CB. misc. Mkt. Value S. SEAS. LAND IMP. TOTAL DATE REMARKS 2--61 v 95- L 11-711d 3 06 (5) 0 � / / r. . I 1 (oA o (9 0,� 61 -L flg 210 -A-Y,I je) LO), �5 0 0 4P21 / AGE BUILDING CONDITION a1010 NEW NORMAL BELOW ABOVE clue Per 'Value FARM Acre Acre Ko Tillable I ---------- Tillable 2 Tillable .3 Woodland FRONTAGE ON WATER Swampland FRONTAGE ON ROAD Brushland DEPTH House Plot BULKHEAD DOCK Total ----------- s ■■■■■■ ■■■■■■■■■■■■■■■■■■■ �. � . ,. yam,.,. • • . . ■■■■■ ■■■■■■■■■■■■■■■■■■■ ■■■■■■ ■■■■■■■■■■■■■■■■■■■ ` .. . ■■■■■■ ■■■■■■■■■■■■■■■■■■■ MOMMISMS ■■■■■■■ ME■E■■■■■■■■■■■■■■■ ■■■■■■■Basement �■■■■■liii■■■■■■■ ■ Foundation lExt. WallsF __Fire Place -• ,. F'' " g ' r_ ■■■■■■ ME �lMEN k/ i'f 9k:.J+i'g}'r`�{•C;^..G „ d imXX.`, - r,:L...„j�L ■■■■■■■ ■■ RISE NOME R i ,� ■. �■■® "77aru5 wl(.t �Drro^,,t� Cet r7prfCA- 301-0" L croDE:S I 0'e�',!1'1 C 0 )RX STATE 8, T APPROVED AS POTED AES R C-U,ri E D A N,c) c 0 q I T!0,'�4 S 0 F DATE:.:f_/2 P1 1 FEE: / A? BY: Cy.".) NOTIFY BUILDING DEPARTIMENT AT ALL P!.I L F,WA ER L, L 765-1802 8 AM TO 4 PM FOR THE FOLLOVjv%jG INSrECTIONS: 1. FOUINDATION - TCVO REQUIRED FOR POURED CONCRETE Cl!j A I'L. 2. ROUGH - FP!1,11ING & PLW!,r_,.!NG Deck L C0'r,;'3J!` �rO C? 3. IN'SU!1.AT;0N CPT L IN 10 . P1 R — 161-011 4. r. AL - CONSTRUCTICNI VUST ST�t"E PI_ C011,1111 - CO C,0 01 1E CIF I 1 10 ri"tt", t: FLETc: FO", C.O. ALL CONSTRUCTION SHALL 1!E-ET THE REQU!REMEINTS OF F THE CODES OF N 7V� YORK STATE. NOT RESPONSIBLE FOR DESIGN OP CONSTRUCTION ERRORS. 201-01' Deck 32'-0" OF 18'-11 1!^:V k_1 I , 4 5 7 Fil 8'- " (M —13'-62" El 2 El 13'-7® th B Let-,-jT'jPiCATE 91-3" Bathroom e 4104 7 C? Bathroom New Loft C) 0or ITI ;0 Steps Rise=8 ax 00 a"Max M 00 Bedroom 0 Refer Tread=9"Min T-72 C. D/W Kitchen 31-311— 00 Living Room C14 O Addition 01 O DIN in ❑7DN C') O . 7 F_ CD Steps,Rise-8 4 I"Max C14 -011O3 UP Tread-9"Min r) T-0" Wood Burning Stove nJ0 I W A A 181-All C." 2 New Bedroom New Bedroom �04 LFA� 104 C? C) F6� tD Bedroom Zn co Dining Room 6 OF 121-311— _n O�� • 00��0 4. 9'-71 111-311 El 0?- 2" 0 El El 0?- pv 0\� O\A 81-01, f 24'-0* Deck C? 241-01' PP NOTES: M LOT 69 LOT 68 Steps Rise=8 Max General: N Tread=9"Min 1 -Occupancy classification-Residential Group R-3 2-Type 5-Wood framed construction to be utilized. New Crawl 3-Building height-25',fire area-1,449 s.f. DN Space SHED 4-Design Criteria-NYS Residential Code R301.2.1.1 and utilized the methods and procedures stipulated in IT — Chapter 2 Engineered Design and Chapter 3 Prescriptiive Design in the American Forest and Paper Association C) Wood Frame construction Manual for One and Two Family Dwelling Units-High Wind Addition and ASCE 7, _I VI Electrical Notes: Swimming CN Pool 1-All electrical work shall be in accordance with the National Electric Code. Existing Cellar 2-All smoke detectors shall be installed in accordance with NFPA 72 and local codes. Site Plan Prepared form Survey 0 Prepared by: SHED Install Smoke Detectors in: L7777i -All bedrooms Barrett, Bonacci&Van Weele,P.C. 15.3' ces -Second floor hall 175 A Commerce Drive -First floor hall Hauppaugue, New York �2 -Living room June 20,2006 U -Cellar SCTM#1000-113-8-10 Scale 1 20' 4-The detectors are to be wired to the building's maim electrical service and be equipped with battery back-up. _j 0 5-The detectors shall be wired so that operation of amy smoke detector shall cause the alarm to round at the others. WINDOW SCHEDULE: NewDe& 6-Carbon monoxide detectors must be installed on each floor of the building in accordance with Suffolk County NOTE:ALL WINDOWS TO HAVE SCREENS. 32.8'— LO specifications. 15.51 New Deck C) DESCRIPTION MANUFACTURER ROUGH OPENING NO. F CASEMENT WINDOW ANDERSON CXW14* 3-01/2'X4'-0112' 6 Lj_ 8.7 New 2 Sto New 1 Story WINDOW NOTES: F2 , CASEMENT WINDOW ANDERSON CW23 4�-0-112'X3'-1rZ 1 Existing New 2nd ''Addition Addition CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA L Story on 32.5' Ground Snow Load Wind Speed Seismic Weathering Frost Line Termite Decay Winter Design Ice Shield Flood Hazard Fj] CASEMENT WINDOW ANDERSON CW25' 4'-41/2-X5'-3/8' 1 0 Existing Depth Temp. Underlayment 1 -Windows and doors are to be wood with double pan(e insulating high-performance low E glass with a max.U value of 0.314. F±1 CASEMENT WINDOW ANDERSON CXW1 3 3-0-1/2'X 341 r2' 1 Required 3 CN 45 psf 120 mph A Severe 36 in. Moderate Slight to 11*F None El BASEMENT WINDOW ANDERSON CW14* 2-4 7/8'X 4!41/2' —12.2' New Deck E N1 CN — to Heavy Moderate 2-Windows and doors are to conform with the AllowabIle Air Infiltration 0 20.9' X. CASEMENT WINDOW ANDERSON CXW1 6' 3-0-1/2'X 15-0-3/8' 7 'N - Rates specified in section 502.1.4.1 in the New York State Energy L0 FIXED SKYLIGHT ANDERSON SK2446 22-1/2'X 44' 1 Conservation Construction Code. El C) 3-Windows and doors are to be equipped with removable plywood DOOR SCHEDULE Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education 4AJ panels as shown in detail on S-15)or shall meet the requirrements of the a Law,Article 145,section 7209,for any person unless acting under the direction ofa licensed C-1 Large Missile Test of ASTM E 1996 for 120 mile per hover wind loads. r. Professional Engineer,Architect,or Land Surveyor,to alter any item in anyway. If an item bearing DESCRIPTION ROUGH OPENING Ld -5 1684 Af the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or 4-Windows shown are manufactured by Anderson SOLID CORE FLUSH 7-6'X T-O'X 1-3/4' Z 00 Land Surveyor shall affix to the item his/her seal and the notation"Altered by"followed by his/her Windows have free operable area of 5.7 s.f.and cleanopening SOLID CORE FLUSH 2-0'X T-O'X 1-3/4' width 20" and height 24" WITHSCREENS <I signature and the date of such alterations,and a specific description ofthe alteraition. NARROLINE GLIDING ANDERSON PATIO DOOR 8'-0'X 16-9-3/4' X -_ ( FWGlM4) 00.0 @ THERMA-TRU FIBER CLASSIC FC23 YO'X 6-8' 0 Z U U10 Scale: 1/4'Scale: 1/4" V-0" Condon Engineering, P.C. X -7-'2- 1 -7 Filiaci Residence so GE PDrawn by : JJC 1755 Sigsbee Road 145 Meday Avenue NOTE: CONTRACTOR TO VERIFY ALL WINDOW AND DOOR OPENINGS. Mattituck, New York 11952U O Mattituck, New York Sol MDate : 5-4-2007 (631) 298-1986 Ridge Vents Ridge Vents Ridge Vents Ridge Vents Ridge Vent Ridge Vents C? N South Elevation North Elevation Eave Vents Eave Vents Eave Vents Eave Vents R-30 Fiberglass R-30C in Vaulted Ceiling Spaces Eave Vents `—R-21 Fiberglass Eave Vents Eave Vents Eav is `R-21 in 2x6 Walls and R-15 in 2A Walls West Elevation East Elevation ''? M R-30 Fiberglass CO i.'�v.:<'rv):ii{;:;<•i:•i'ri :•:}; {. •fir ;;os c� CO 41 = Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education FScale: V-0" Condon Engineering, P.C. F�I�a C� Residence Law,Article 145,Section 7209,for any person unless acting under the drection of a licensed Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing 1755 Si sbee Road the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Drawn by : JJ C g 145 Meday Avenue Land Surveyor shall affix to the item his/her seal and the notation"Altered by"followed by his/her Mattituck, New York 11952 Mattituck, New York signature and the date of such alterations,and a specific description of the alteration. (631) 298-1986 Date : 5-4-2007 Wood Framing 1-All lumber is to be No.2 or better Douglas Fir Larch(N)with the following minimum specifications: 10"0 Somo Tube Footing Typical D - Fb=825 psi i 4 2x6 Wall Studs I Fc perp Ps625 psi (2)2x8 ACQ I E=1,600,000 psi Truss 2-All Laminated Veneer and Power Beam Glulam Lumber are to have the following minimum 2x4 Wall Studs I ( I See Detail 0 1 st Floor in this Area ° I specifications: o to Match Existing S-4 Truss I Fb=2,900 psi ,L 2x8 ACQ Ledger I I ( ® of Fv 290 psi CO e"0 Bolts 16"OC 5.25 x 9.25 Power Beam GluLam Door Header See Detail I I0 0 0 o Fc perp=650 psi X ( X X ;o ( E=2,000,000 psi (2)2x10 Header _J_ — /2x10 ader I v N C) 0 �' Glulams( o0 X to ( Fb=3,000 psi O O N � U I Fv=290 psi 5.25 x 14 LVL E=2,100,000 psi �= J C[fl (;2)2 x10 o o X N � I Truss N 3-All beams fabricated with multiple Laminated Veneer Lumber boards are to be nailed/bolted in See Detail ( )2 8 2 x _ 2 x 8 I I accordance with the manufacturer's specifications. I to ( ) Load earing Wall I ® (2)2 x 8 0 I 4-All TJls are to be installed in accorrdance with the manufacturer's specifications and shall include co Truss I Loa B aring all I squash blocking and web stiffeners at bearing points on girders and other load bearing areas. See Detail to R ( I 5-All straps,connectors, plates, bouts, nails,etc.are to be galvanized or stainless steel. TIE Ceiling Jc ists to Designated connectors,strap etc.on Ithese drawings are made by Simpson unless indicated I R f See De it ( ( otherwise.All connectors,straps etc. are to be nailed/bolted in accordance with the manufacturer's DN o w specifications. 0 Q U I o I I ao I 6-All floor sheathing is to be 2 32 inch AC type plywood,tongue and groove,with an APA span uP =5 N I rating of 48124. Floor sheathing shall Ibe glued and screwed to the floorjoists(6"O.C.edges and Load Bearing Wall ~ I 12"O.C. field). D I S-4 7-All wall sheathing is to be 1%2 inch APA Rated Exposure 1 plywood and shall be nailed with 8d Al common nails 6"O.C.edges and 12"O.C.field. I8-Solid blocking is to be installed every 8'max or mid span of all floorjoists with spans exceeding 8'. 2x6 Wall Studs on 2nd Floor 9-Double joists are to be installed bellow parallel walls. S-4 Roof Framing Plan g 10-Blocking is to be installed at all pwint load bearing points. S-4 11 -Walls are to be framed with 2x6 imch studs spaced 16 inches OC unless indicated otherwise. 2x4 Wall Studs 12-All bolts nuts and washers are to Ibe stainless steel or hot dipped galvanized. 2nd Floor FramingPlan 1st Floor in this Area to Match Existing 13-Window and door headers are to Ibe double 2x8 unless specified. Steel 1 -All steel is to be ASTM Specificatiom A-36 3'-0" 8'-0" 8'-0" 8'-0" 3'-0" 2-All bolted connections are to be meade with A-325 bolts. 8"0 Sono Tube Footing Typical 3-Round columns are to be ASTM Specification A53-GR.B — I — — — — — — — (2)2x8 AC 2xl2 ACID o 16"0 Sono Tube Footing Typical I rn Stringers ¢ 2xl2 ACQ U N — Stringers — — — — — 8'-6"— 5i-4" 5'-4" --5'-4" v I Typical — — (2)2x8 AGE I i[> 10"0 I ono Tube Fc oting Typical Design Loads: — — — — ZoI L -Roof -Live Load-30 psf o 2x8 ACQ Ledger Biased on ASCE-7 and Pg=45 psf `Y' 3'-0" o s"0 Bolts 16"OC I 1per Figure R301.2(5} Zo ;', — — — — — — — Dead oad-15 psf — — — — — — — — — list Floor -Live Load-40 psf _17N Foundation Vent I -Dead Load-15 psf -2nd Floor -Sleeping Areas -Live Load-30 psf Step Up I — — — I -Other Areas -Live Load-40 psf in Footing I I -Dead Load-15 psf 9'-3" 9'-4 4" I 3"0 Round Col mn 3"0 Round Column I -Attic -Live Load-20 psf -Dead Load-15 psf 2'x2'x12" Footing I o � o Load Bearing Wall o N I -Decks-Live Load-40 psf 2'x2'x12"Footing Below Wall Above I -Dead Load-15 psf DN I N Design Criterita-NYS Residential Code R301.2.1.1 and utilized the methods Foun ation Pocket r- � ew(3 2�10 Drop Girder I g F 7 I D ( and procedures stipulated in Chapter 2 Engineered Design and Chapter 3 w Foundation Pocket Prescriptive Design in the American Forest and Paper Association Wood Frame 0 o I _ $ I Construction Manual for One and Two Family Dwelling Units-High Wind L— Addition and ASCE 7. Foundation Pocket �* I Existing(3)2x10 New )2xl0 Drop Girder 2'x2'xl2"Footing �' I Foundation Pocket 2'x2'x 2"Footing 2'Step Up I 3"0 Round C lumn A, Footing Foundation Vent 3'Wide Crawl Space Access Opening 7'_7 III New 8" Poured Concrete Foundation �`' � ' oOti g and 16"x 10"Footing A I New 8" Poured Concrete Foundation S-4 Plans are prepared by Condon Engineering,P.C. It is a violation of the New Yak State Education , — S-4 — _ and 16"x 10"Footing Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed 4" Professional Engineer,Architect,or Land Surveyor,to alter any item in anyway.Ifian item bearing Existing CMU Foundation7 the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Zz C1 2x8 ACQ Ledger Step Footing Land Surveyor shall affix to the item his/her seal and the notation"Altered by"followed by hi&ber 6'-0" 6'-0" 6'-0" 6'-0" Up 8"0 Bolts 16"OC B See Detail signature and the date of such alterations,and a specific description of alteration. 2 S-4 1� Z, 8 (2)2x8ACQ Scale: 1/4" = 1'-0- Condon Engineering, P.C. 10"0 Sono Tube Footing Typical 1st Floor Framing Plan g g� Filiaci Residence Foundation Plan Drawn by : JJC 1755 Sigsbee Road 145 Meday Avenue Mattituck, New York 11952 Mattituck, New York Date : 5-4-2007 (631) 298-1986 ° ° o° FRAMING 3"No.8 SCREWS 12"OC LIGHT WOOD-FRAME WALL Simpson LSTA30 Ridge WASHER(TYP.) — — — — +— — — — — Strap at each Rafter SIMPSON LSTA36 �-Y"PLYWOOD " STRAP L—�—t I O I O GLASS- PLASTIC-COATED PERMANENT WOOD TOP- SCREW ANCHORS O _Typical Window and Door Header GLASS — -- �- Nt S CONNE-6 y"PLYWOOD PAFEA Strapping Detail Each Corner FRAMING SEE 1 3 O Simpson H2.5 Hurricane Tie 2x4 Ceiling Joists/Roof Ties NTS DEAIL at each Rafter Tail WASHER(TYP.) PLYWOOD OPENINGS PROTECTION; Zone 2 Zone 3 � THICKNESS DEPENDS ON WINDOW Z Zone 1 0 Add Blocking As Necessary 3 No.8 SCREWS 12"OC OPENING WIDTH(I) DETAIL A-TYPICAL ATTACHMENT OF PLYWOOD OPENINGS PROTECTION TO Field sa O.C. 12n O.C. 4" O.C. WOOD-FRAME BUILDING Panel Edges 6" 0• • BOTTOM Alternate to 120 MPH Certified (NOTE: IN LIEU OF SCREWS,LUGS 6" O.C. 4" O.C. STUD PLATE Window Installation WITH NUTS AND WASHERS MAYBE Nailing Requiirements for 120 MPH, 3 Sec. Peak Gust, Rafters USED R,MMSr Plywood Panel Window and Door 2" Thick Roof'Sheathing with 8d Common Nails PLATE Protection for Wood Framed Buildin s Roof Sheathing Plan V-cut shear blocking 4 " Scale;: 118" = 1'-0" Simpson ST22 Strap at every other scud I *;t Typical 2nd Floor Strapping Detail NTS 2x8 ACQ Ledger Trus Joist rim board for shear blocking(between joists). co 5/"0 Galv Bolts 8"0 Anchor Bolts 32"OC 0 Anch"a"ti3zoc Field trim to match joist depth at outer edge of 16"OC Staggered wall or locate on wall to match joist depth. 2x6 ACQ sill (2)2x8 ACQ Bean I Zzf opper Termite Shield DIV. '/ q/ y (2) 8"O Galy. Bolts S' peon LSTA18 13 3 :i; • *L7 Y 8"Q Galv Bolt Simpson LUS26 ZM ax xpansion joint and joint sealer Y" ,."`"'W' 44 ACQ 44 ACQ Knee Brace Maximum allowable V-cut ! Simpson L P5 g"• ` '' 2"poured concrete rat slab SHEAR BLOCKING and VENTILATION HOLES %"Q Galv Bo)lt a' Simpson BP Shear Blocking Details Section Load Path Detail Moisture/damp pr of co. � Scale 4"= NTS B 5.25 x 14 LVL r.:� -,�.o' Typical Wall and 1'-0" Structural Ridge 4; Sill Strapping Detail ubbase-compactable fill Simpson HGU 5.5SDS Hanger 16" mil vapor barrier � / Foundation Section A (2)No.5 Rebar (2)2x10 Scale V'0-0" (2)2x10 Packing Table 3.1 Nailing Schedule(Wood Framed Construction Manual 1995 SBC High Wind Edition,Page 110) Foundatlion Notes: Joint Description NumberofNails Nails cin ROOF NAILING (2)2X10 4 The contractor is to verifyall measurements in the field and an discrepancies are Rafter to Top Plate(Toe-nail 4-8d y p -nailed) per rafter to be brought to the Engineer prior to construction. Ceiling Joist to Top Plate(Toe-nailed) 4-8d per joist Ceiling Joist to Parallel Rafter(Face-nailed) n/a each lap Ceiling Joist Laps Over Partitions(Face-nailed) n/a each lap 1 -All Concrete 3,500 psi after 2t8 days minimum. Collar Tie to Rafter(Toe-nailed) n/a per tie 4 +,. Blocking to Rafter(Toe nailed) 2-8d each end 2-All rebar ASTM A-615 Grader 60. Rim Board to Rafter End Nail 2-16d each end �:;: :• '' Simpson PB44 WALL FRAMING ZMaX .;• :: 3-Footings are to be installed on undisturbed virgin soil.The bottoms of all Top Plate to Top Plate(Face-nailed) 2-16d(1) per foot footings are to be installed a minimum of 3'below grade unless indicated Top Plates at Intersections(Face-nailed) 4-16d joists-each side Stud to Stud(Face-nailed) 2-16d 24"o.c. otherwise. Header to Header(Face-nailed) 16d 16"o.c.along edges o 0 0 0°o° 2x10 Sandwiched by(2)2x10 RR o o Poured Concrete Filled 10„Dia•Sono Tube 4- All snap off form ties are to Ibe removed and remaining openings are to be Top or Bottom Plate to Stud(End Nailed) 2-16d per 2x4 stud 00 Footing sealed/grouted. 3-16d per 2x6 stud 4-16d per 2x8 stud 5-The foundation contractor shiall coordinate with the plumbing and electrical Bottom Plate to Floor Joist,Band Joist,End joist or Blocking(Toe-nailed) 2-16d (1,2) per foot contractors relative to installation of sleeves and other penetrations prior to pouring FLOOR FRAMING Balcony Detail concrete. Joist to Sill,Top Plate or Girder(Toe-nailed) 4-8d per joist C 6-Installl isolation joints along foundation walls and at column and other floor Bridging to Joist(Toe-nailed) 2-8d each end penetrations. Blocking to Joist(Toe-nailed) 2-8d each end Scale Z"=1'-0" Blocking to Sill or Top Plate(Toe-nailed) 3-16d each block Ledger Strip to Beam(Face nailed) 3-16d each joists 1 ze 7-Foundation excavation is nott to be back filled prior to the installation of the floor Joist on Ledger to Beam(Toe-nailed) 3-8d per joist framing. Band Joist to Joist(End-nailed) 3-16d perjoist Band Joist to Sill or Top Plate(Toe-nailed) 2-16d (1) per foot ROOF SHEATHING 8-Backfill along foundation wallls is to be clean material and is to be mechanically compacted in 6" lifts to 95%of imaximum dry density, Structural Panels 8d (Detail sheet S-3) 1" 28 - - - - 28" CEILING SHEATHING — — — — Gypsum Wallboard 5d coolers 7"edge/10"field — — — — WALLSHEATHING 3 2" Structural Panels 8d 6"edge/12"field c� '� ^C04do Gypsum Wallboard 5d coolers 7"edge/10"field Truss Detail t FLOORSHEATHINGq"0 Bolts D Scale "=1'-0" Structural Panels 1"or less 8d 6"edge/12 field tea 168.4 (1)Nailing requirements are based on wall sheathing nailed 6"on-center at the panel edge. If wall sheathing Is nailed 3" on-center at the panel edge to obtain higher shear capacities,nailing requirements for structural members shall be - doubled,or alternate connectors,such as shear plates,shall be used to maintain load path. Scale (2)When wall sheathing is continuous over connected members,the tabulated number of nails shall be permitted to be Sv'_.. `— C:' reduced to 1-16d nail per foot. Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education Scale: 1/4a — 1'-�" Condon Engineering P.C. Law,Article 145,Section 7209,for any person unless acting under the direction of a licensedF I C Residence Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or 1755 Si sbee Road Land Surveyor shall affix to the item his/her seal and the notation"Altered by"followed by his/her Drawn by : JJ C 9 145 M eday Avenue signature and the date of such alterations,and a specific description of the alteration. Mattltuck, New York 11952 Mattituck, New York Date : 5-4-2007 (631) 298-1986 00 Steps Rise=8 4"Max Graspable Railings to be Tread=9"Min provided stair 3'-1 1" 30'-9' Deck 16'-0" ti 20'-0" CV 00 Deck 32'-0" N 18'-11" ❑3 ® 8'-72" 4 13'-61. © Access to storage ® 1 O O o 0 9' 3" area above door �," Oven Pocket Door 6 Bathroom Graspable Raillings to be Bathroom 14"x 53"fixed provided stair _ 1" �Storage Above Refer Window to be 1"" Steps Rise-8 a Max g tempered glass Steps Rise=8 a Max Tread=9"Min 7'-8- Bedroom © DM = Tread=9 Min Kitchen EO Living RoomED 2'-1 1" O r- 0 v 7 O p Cl) El a N New Closet 15"MIN. o Steps Rise=814"Max 3'-0"—J Tread=9"Min Pocket Door � uP � Walls around stair 38"Ht. 3'-0" 1 Wood Burning Stove Q 18-72" 0 co New Bedroom © 00Bedroom a' Dining Room © s � L1N� ERA ° 00 a a 10'-3" a o 0 O\,N 00 &r a a O p,N N p,M o 31' 4 0 -73 R��w� \ 24'-0" Deck \v N PCS� - LOT 69 LOT 68 NOTES: N C) General: CV Steps Rise=8 4"Max C\4 Tread=9"Min 1 -Occupancy classification-Residential Group R-3 N 2-Type 5-Wood framed construction to be utilized. D New Crawl 3-Building height-25',fire area-1,449 s.f. SHED Space 117'— L 4-Design Criteria-NYS Residential Code R301.21.1 and utilized the methods and procedures stipulated in 0 b Chapter 2 Engineered Design and Chapter 3 Prescriptive Design in the American Forest and Paper Association In 10' Wood Frame construction Manual for One and Two Family Dwelling Units-High Wind Addition and ASCE 7. N Swimming Graspable Railings Pool to be provided stair 5-The living room rear access doors at the deck tco be provided with an audible alarm or self closing doors With self latching devices to prevent child access to the!swimming pool in accordance with section AG105.2.9 of the I`_ NYS Building Code. The swimming pool may be etquipped with a powered safety cover or the deck access to thE 0 Existing Cellar yards shall be equipped with self closing doors with self latching devices in accordance with section AG105.2.9. SHED J rJ Site Plan Prepared form Survey �`/ Electrical Notes: Prepared by: �6. 15.3' 1-All electrical work shall be in accordance with the National Electric Code. Barrett, Bonacci&Van Weele,P.C. 175 A Commerce Drive 2-All smoke detectors shall be installed in accordance with NFPA 72 and local codes. Hauppaugue, New York v June 20,2006 Install Smoke Detectors in: SCTM#1000-113-8-10 0 _.--�--, -All bedrooms Scale 1"=20' _1 0 -Second floor hall -First floor hall WINDOW SCHEDULE: -Living room New Deck NOTE:ALL WINDOWS TO HAVE SCREENS. o -Cellar DESCRIPTION MANUFACTURER ROUGH OPENING No. 15.5' ib' rn � 4-The detectors are to be Wired to the building's retain electrical service and be equipped with battery back-up. ElCASEMENT WINDOW ANDERSON CXW14* 3'-01/2'X4'-01/2" 6 New Deck 0 30.0 5-The detectors shall be wired so that operation otf any smoke detector shall cause the alarm to sound at the Q CASEMENT WINDOW ANDERSON CW23 4'-0-1/2"X3'-1/2" 1 LLB8 716. 1 New 2 S Wew 1 Stay v) ' CASEMENT WINDOW ANDERSON CW245' 4'-0-1/2'X4'-5-3/8' 1 ,Addition AAddit others. Existing New2nd 325, CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA n r; ; jI �4 CASEMENT WINDOW ANDERSON CXW13 3'-0-12"XX-0-12" 1 0 Story� U + _� ij �1J 5-13-2009 VARIOUS REVISIONS 6-Carbon monoxide detectors must be installed om each floor of the building in accordance with Suffolk County It - Ground Snow Load Wind Speed Seismic Weathering Frost Line Termite Decay Winter Design Ice Shield Flood Hazard 5❑ BASEMENTWINDOW ANDERSON CW14' 2'-47/8'X4'-0-12" 3 �, I REVISIONS specifications. Depth Temp. Underlayment © CASEMENT WINDOW ANDERSON CXW16- T-0-12"X V-0-3/8' 7 N 12.2' New oed N Required I t" 0 FIXED SKYLIGHT ANDERSON SK1646 141/2"X 44' 1 LO 20 5' 45 psf 120 mph A Severe 36 in. Moderate Slight to 11°F None LL ® FIXED SKYLIGHT ANDERSON SK4446 42"X46' 1 Q to Heavy Moderate BL.OG.DEPT. OF N ., 0 TOWN OF SOUTHOLD �G Cvt WINDOW NOTES: CASEMENT WINDOW ANDERSON CN12 1'-9'X7-05/8" ,(FIXED) .r `Z 1 -Windows and doors are to be wood with double Ipane insulating ry high-performance low E glass with a max. U value off 0.34. DOOR SCHEDULE n Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education L1.1 Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed 2-Windows and doors are to conform with the Allovnrable Air Infiltration DESCRIPTION ROUGH OPENING Z Professional Engineer,Architect,or Land Surveyor,to alter any item in any. If an item bearing % �9t2 ,.. f Q the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or 'l Q Rates specified in section 502.1.4.1 in the New York;State Energy 0SOLID CORE FLUSH 2'-6"X T-0"X 1-3/4' J ( l Land Surveyor shall affix to the item his/her seal and the notation"Altered by"followed by his/her 1 " OF( Conservation Construction Code. v ' signature and the date of such alterations,and a specific description of the alteration. © SOLID CORE FLUSH 7-0"X T-0"X 1-3/4" to 0.O O 3-Windows and doors are to be equipped with remrovable plywood © FRENCHWOOD PATIO8'-0"X 15'-9-3/4' X 1 0 WITHSCREENS ANDERSON FWG16080A O panels as shown in detail on S-5 or shall meet the requirements of the U Z nI Large Missile Test of ASTM E 1996 for 120 mile per hour wind loads. @ THERMA-TRU FIBER CLASSIC FC23 320'X 6'-8' ` �� V v \ ) W WIN A I DOOR 4'-1'X 6'-11" 0 0 � ` v O ANDERSON FWO-41611APLR '` GVF \ I • 4-Windows shown are manufactured by Anderson X '2 � V " _ n S � of p,R P Scale: 1/4 - 1 -0 Condon Engineering, P.C. • * Windows have free openable area of 5.7 s.f.and clear opening O Zq ,7 0 EOGE �( I��t i ac i Residence width=20" and height=24" ( ) Drawn b : JJC 1755 Sigsbee Road 145 Meda Avenue NOTE: CONTRACTOR TO VERIFY ALL WINDOW AND DOOR OPENINGS. v O y y Mattituck, New York 11952 M Mattituck, New York Date : 5-4-2007 (631) 298-1986 Ridge Vents Ridge Vents Ridge Vents s - Ridge Vents Ridge Vents - -, _ - - - Ridge Vents - _ I T _ - _ if I lilt 0 — - N 4"min. co co North Elevation South Elevation ® E Zt CV Eave Vents Eave Vents 2x6 11dar Ridge Eave Vents Eave Vents 2x4 Cedar RR @ 16"o.c. Simpson LUC26Z 2x6 Cedar 4x4 Cedar Beam beam to Ledger Eave Vents 2x6 Cedar Beam Eave Vents S 1x6 Cedar Ledgerw/ - Timberlok screws @ 12"o.c. R-30 Fiberglass R:30C in Vaulted Ceiling Spaces Ea Vents Eave Vents 2x6 Cedar beam to 4x4 with 4x4 Cedar (2)8"Timberlok screws 4" min. R-21 Fiberglass 4"min. 4x4 Cedar beam to 4x4 post with(2)12"Timberlok screws 4" ECID Cl) 4"min. 4"min. " min. in West Elevation P� R-21 in 2x6 Walls and R-15 in 2x4 Walls East Elevation 5-13-2009 VARIOUS REVISIONS (2)2x8 ACQ REVISIONS 24 DJ @ 16"o.c. �pF NEW 2x8 A Ledger J' .,;• ; s"fd Bolts 16"OC � � ji.Co O •:�. � R-30 Fibergllass M ME 0819 A Simpson PB44 Typical' Building Section ZMax P (3FESS�4�P Poured Concrete Filled 10"Dia.Sono Tube Footing Front Deck Detail Scale: 1/4" = V-0" Condon Engineering, P.C. /► Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education , F i I i a C i Residence Scale '=1'-0" Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing 1755 S I sbee Road the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or Drawn by : JJC 145 Meday Avenue Land Surveyor shall affix to the item his/her seal and the notation'Altered by"followed by his/her Mattituck, New York 11952 Mattituck, New York signature and the date of such alterations,and a specific description of the alteration. (631) 298-1986 Date : 5-4-2007 10"0 Sono Tube Footing Typical Wood Framing 1 -All lumber is to be No.2 or better Douglas Fir Larch(N)with the following minimum specifications: S-4 2x6 Wall Studs D (2)2x8 CQ - Fb=825 psi Fv=95 psi Fc perp=625 psi 2x4 Wall Studs E=1,600,000 psi 0 1st Floor in this Area o to Match Existing S-4 Truss 2-All Laminated Veneer and Power IBeam Glulam Lumber are to have the following minimum 2x8 ACQ Ledger I I See Detail ( specifications: X I LVL's N $'0 Bolts 16"OC 5.25 x 9.25 Power Beam GluLam Door Header Fb=2,900 psi 1Fv=290 psi I I I I Truss I (2)2x10 Header _ — /2x10 r 1 � � See Detail _ 0 Fc perp-650 psi 0 1 1 0 0_ o o I I E=2,000,Ooo psi (2)2 x 10 co X N I " I " W �_ X N N N 0x N Glulams 0 o "'I ovo I I - Fb=3,000 psi I I X N N N � I Fv-290 psi Truss 1 (2)2 x o O 5.25 x 14 LVL E=2,100,000 psi ®Load B See Detail (2)2 x 10 O co aring Wall � 1 I N 3-All beams fabricated with multiple I Laminated Veneer Lumber boards are to be nailed/bolted in Truss 1 (2):2 x 8 I I accordance with the manufacturer's slpecifications. See Detail 1 4-All TJls are to be installed in accorrdance with the manufacturer's specifications and shall include D 7"x 7"Wood Column squash blocking and web stiffeners att bearing points on girders and other load bearing areas. � � 1 OR o � I 5-All straps,connectors,plates,boltts,nails,etc.are to be galvanized or stainless steel. o I I Designated connectors,strap etc.on/these drawings are made by Simpson unless indicated o CD ZN I I otherwise.All connectors,straps etc.,are to be nailed/bolted in accordance with the manufacturer's co UP I specifications. Load Bearing Wall '-' I � I I 6-All floor sheathing is to be 2%2 incth AC type plywood,tongue and groove,with an APA span rating of 48/24.Floor sheathing shall the glued and screwed to the floor joists(6"O.C.edges and 12"O.C. field). S-4 7-All wall sheathing is to be'%2 inch APA Rated Exposure 11 plywood and shall be nailed with 8d common nails 6"O.C.edges and 12" O.C.field. 1A Cedar Ledger w/ Simpson LUC26Z 2x6 Cedar 8-Solid blocking is to be installed every 8'max or mid span of all floor joists with spans exceeding Tim erlok screws @ 12"o.c. beam to Ledger D 8' S-4 2x6 Wall Studs on 2nd Floor 9-Double joists are to be installed below parallel walls. 2x4 Wall Studs Roof Framing Plan g 10-Blocking is to be installed at all point load bearing points. 1st Floor in this Area S-4 E to Match Existing 2x4 Cedar RR @ 16"o.c.m� m 11 -Walls are to be framed with 2x6 imch studs spaced 16 inches OC unless indicated otherwise. DI �I I D o` a 12-All bolts nuts and washers are to be stainless steel or hot dipped galvanized. m 4x4 Cedar Post NI co I IN 13-Window and door headers are to be double 2x8 unless specified. CD o 4x4 Cedar Beam 4x4 Cedar Beam Steel 4x4 Cedar Beam 1 -All steel is to be ASTM Specification A-36 2nd Floor Framing Plan 2-All bolted connections are to be maade with A-325 bolts. 8"0 Sono Tube Footing Typical (2)2x8 ACQ 3-Round columns are to be ASTM:Specification A53-GR.B 2x12 ACQ Stringers I I Typical I 16"0 Sono Tube Footing Typica O I I (2)2x8 ACQ I �I co co NI vl 7'-9" 7'-3" (D Q 10"0 Sono Tube Footing Typic I I I 2x6 FJ ACQ 0 o d 16"OC o 0 o Design Loads O° < < < < co - Roof -Live Load-30 psf O O O N N I N 1 X, 11 N I (Based on ASCE-7 and P 45 psf v N v v 2x8 ACQ Ledger c N g — — — — — — — — — — — _ v I I 8"0 Bolts 16"OC v IZo "I per Figure R301.2(5) (— — — -Dead Load-15 psf Column to footing with a I — — — — — — — _ — — Simpson PB66 ZMax �' Ex.Bilco Door _ _ _ _ _ _ _ - 1 st Floor -Live Load-40 psf p (tYP) �' -Dead Load-15 psf N Foundation Vent I _ � ( -_ 7 2nd Floor -Sleeping Areas -Live Load-30 psf 2'Step Up I — — J I 2x12 ACQ -Other Areas -Live Load-40 psf in Footing I Stringers -Dead Load-15 psf (2)2x8 ACQ Typical -Attic -Live Load-20 psf 9'_3" g'�4• Crawlspace Access 8"x 16"CMU ier 8"x 16"CMU Pier ( � P -Dead Load-15 psf 2'x2'x12'Footing i o o Load Bearing Wall � 2'x2'x12"Footing 0 co I - Decks-Live Load-40 psf F Below Wall Above f I -Dead Load-15 psf _ � (3)2x8 (2)2x8 AC N 41 �1 X U D I J I C" New(3)2x10 Drop Girder Design Critelria-NYS Residential Code R301.2.1.1 and utilized the methods I I Foun ation Pocket o 0 D N Foundation Pocket I and procedulres stipulated in Chapter 2 Engineered Design and Chapter 3 I W N I Prescriptive(Design in the American Forest and Paper Association Wood Frame 0 0 C) � � ( �— I Construction/Manual for One and Two Family Dwelling Units-High Wind _/ Foundation Pocket I (Existing(3)2x10 New )2x10 Drop Girder I Addition and/ASCE 7. 2'x2'x12"Footing � I Foundation Pocket 2'x2'x 2"Footing I 5-13-2009 VARIOUS REVISIONS 2'Step Up Foundation Vent I 8' x 16"CMU Pier 8"x 16"CMU Pier I REVISIONS in Footing 3'Wide Crawl Space Access Opening 7.7 IA INew 8"Poured Concrete Foundation „tt ik g and 16"x 10"Footing A I New 8"Poured Concrete Foundation Plans are prepared by Condon Engineering,P.C. It is a violation of the New YorkState Education r { and 16"x 10" Footing7 Law,Article 145,Section 7209,for any person unless acting under the directioni of a licensed 8'-3 4" — — Professional Engineer,Architect,or Land Surveyor,to alter any item in any way..If an item bearing J�. 8t•��2 '{,'� the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engiineer,Architect,or Existing CMU Foundation C3 2x8 ACQ Ledger Land Surveyor shall affix to the item his/her seal and the notation"Altered by"followed by his/her �OffSS�f, , 0 Step Footing 0 �" . signature and the date of such alterations,and a specific description of the alteration. 6'-0" 6'-0" 6'-0" 6'-0" �* � 0 8 0 Bolts 16 OC B See Detail rL = 8 2" m m S-4 (2)2x8 ACQ 10"0 Sono Tube Footing Typical 1st Floor Framing Plan Scale: 1l4" = 11-0" Condon Engineering, P.G. Filiac Residence sidence KIM 1 755 $i sbee Road Drawn by : JJC 9 145 Meday Avenue Foundation Plan Mattituck, New York 11952 Mattituck, New York Date : 5-4-2007 1 (631) 298-1986 0 FRAMING O ® 3"No.8 SCREWS 12'OC LIGHT WOOD-FRAME WALL O — 0 Simpson LSTA30 Ridge WASHER(TYP.) — — Strap at each Rafter SIMPSON LSTA36 �Y2'PLYWOOD �T STRAP \J I O O I O GLASS PLASTIC-COATED PERMANENT WOOD ® I o IO o .�.�, SCREW ANCHORS 1 tO 1 T® Typical Window and Door Header GLASS ' — —t — — — RZSR Strapping Detail Each Corner Yz PLYWOOD PER RKiER FRAMING SEE O O Simpson H2.5 Hurricane Tie 2x4 Ceiling Joists/Roof Ties NTS oEA IL at each Rafter Tail WASHER(TYP.) PLYWOOD OPENINGS PROTECTION; THICKNESS DEPENDS ON WINDOW Add Blocking As Necessary \-3"No.8 SCREWS 12'OC OPENING WIDTH(I) Zone 1 Zone 2 Zone DETAIL A-TYPICAL ATTACHMENT OF 6" O.C. 12" O.C. 4" O.C. PLYWOOD OPENINGS PROTECTION TO Field WOOD-FRAME BUILDING Panel Edges PPLATE''� Alternate to 120 MPH Certified NOTE: IN LIEU OF SCREWS,LUGS 6" O.C. 4" O.C. STUD Window Installation WITH NUTS AND WASHERS MAY BE Nailing Requirfements for 120 MPH, 3 Sec. Peak Gust, RIM J015T Rafters USED Plywood Panel Window and Door 2 PLAiE " Thick Roof:Sheathing with 8d Common Nails TOP Protection for Wood Framed Buildings Roof S►heathing Plan V-cut shear blocking 4 Scale:; 1/8" = V-0" Simpson ST22Strap at every other sWd Typical 2nd Floor Strapping Detail NTS 2x8 ACQ Ledger Trus Joist rim board for shear blocking(between joists). co %"0 Galy Bolts 8"0 Anchor Bolts 32"OC a Field trim to match joist depth at outer edge of 16"OC Staggered X wall or locate on wall to match joist depth. 2x6 ACQ sill Xzz""' opper Termite Shield Y� pson LSTA18 Y (2)2x8 ACQ Beam (2) 8 0 Galy.Bolts Y2 2x4 ACQ(Knee Braces Simpson LUS26 • • y1. V �T I I 1_JX2flush bottom of deck joist ZMax —Expansion joint and joint sealer :.:.......:.... <;s;;::::;::: >:;>: ;>;=; 6x6 ACQ ' Maximum allowable V-cut a - Simpson 5 8"- 2"poured concrete rat slab SHEAR BLOCKING and VENTILATION HOLES a Simpson BP Shear Blocking Details Moisture/damp pr of coa - Section Loald Path Detail NTS • ...:. .:....................:: ::. B 5.25 x 14 LVL <- Typical Wall and Scale 4"=1`-0" Structural Ridge Sill Strapping Detail ubbase-compactable fill Simpson HGU 5.5-SDS Hanger 1-1 6" mil vapor barrier Foundation Section �► (2)No.5 Rebar (2)2x10 ScaleY2"_'1'-0" (2)2x10 Packing Table 3.1 Nailing Schedule(Wood Framed Construction Manual 1995 SBC High Wind Edition,Page 110) Foundation Notes: Joint Description Number of Nails Nail Spacing ROOF NAILING (2)2X10 The contractor is to verify all measurements in the field and any discrepancies are Rafter to Top Plate(Toe-nailed) 4-8d per rafter to be brought to the Engineer pdiior to construction. Ceiling Joist to Top Plate(Toe sailed) 4-8d per joist Ceiling Joist to Parallel Rafter(Face-nailed) n/a each lap ~� 1 -All concrete 3,500 psi after 28 days minimum. Ceiling Joist Laps over Partitions(Face sailed) n/a each lap Collar Tie to Rafter(Toe-nailed) n/a per tie o Blocking to Rafter(Toe nailed) 2-8d each end 2-All rebar ASTM A-615 Grade 60. Rim Board to Rafter End Nailed 2-16d each end Column to footing with a Simpson PB66 ZMax(typ.) WALL FRAMING !' ? 3-Footings are to be installed oin undisturbed virgin soil.The bottoms of all Top Plate to Top Plate(Face sailed) 2-16d(1) per foot footings are to be installed a minimum of 3'below grade unless indicated Top Plates at Intersections(Face sailed) 4-16d joists-each side Stud to Stud(Face sailed) 2-16d 24"o.c. otherwiSE'. Header to Header(Face sailed) 16d 16"o.c.along edges 0 0°° 2x10 Sandwiched by(2)2x10 RR o o Poured Concrete(Filled 10"Dia.Sono Tube 4- All snap off form ties are to be removed and remaining openings are to be Top or Bottom Plate to Stud(End Nailed) 2-16d per 2x4 stud °° Footing sealed/grouted. 3-16d per 2x6 stud 4-16d per 2x8 stud 5-The foundation contractor shall coordinate with the plumbing and electrical Bottom Plate to Floor Joist,Band Joist,End joist or Blocking(Toe-nailed) 2-16d(1,2) per foot contractors relative to installatiom of sleeves and other penetrations prior to pouring FLOOR FRAMING Balcony Detail s concrete. Joist to Sill,Top Plate or Girder(Toe ailed) 4-8d per joist 6-Install isolation joints along foundation walls and at column and other floor Bridging to Joist(Toe-nailed) 2-8d each end C penetrations. Blocking to Joist(Toe-nailed) 2-8d each end Scale 2"I=1'-0" Blocking to Sill or Top Plate(Toe-nailed) 3-16d each block Ledger Strip to Beam(Face-nailed) 3-16d each joist pr 1 2^ + 1 7-Foundation excavation is not to be back filled prior to the installation of the floor Joist on Ledger to Beam(Toe-nailed) 3-8d per joist framing. Band Joist to Joist(End-nailed) 3-16d per joist Band Joist to Sill or Top Plate(Toe-nailed) 2-16d(1) per foot ROOF SHEATHING 5-13-2009 VARIOUS REVISIONS 8-Backfill along foundation wall9s is to be clean material and is to be mechanically i compacted in 6" lifts to 95%of rmaximum dry density. Structural Panels 8d (Detail sheet S-3) i 21 ' REVISIONS 2$^ CEILING SHEATHING — — ;0 — — of Nl Gypsum Wallboard 5d coolers 7"edge/10'field — — — — — `�'�. WALL SHEATHING 3 2" ��` N�' Structural Panels 8d 6'edge/12"field co Gypsum Wallboard 5d coolers 7'edge/10"field Truss Detail FLOOR SHEATHING Structural Panels q" Bolts Scale}'=1'-0' �. 1"or less 8d 6'edge/12'field (1)Nailing requirements are based on wall sheathing nailed 6"on-center at the panel edge. If wall sheathing is nailed 3" on-center at the panel edge to obtain higher shear capacities,nailing requirements for structural members shall be Scale 1"=1'-0" doubled,or alternate connectors,such as shear plates,shall be used to maintain load path. i (2)When wall sheathing is continuous over connected members,the tabulated number of nails shall be permitted to be reduced to 1-16d nail per foot. Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education ' Condon Engineering, ■ ■ Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Scale: 1/4"= 1 -0" i l ii a C i Residence Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing the seal of an Engineer,Architect,or Land Surveyor is altered,the altering Engineer,Architect,or 1755 SI Sbee Road Land Surveyor shall affix to the item his/her seal and the notation'Altered by"followed by his/her Drawn by : JJC 145 Meday Avenue signature and the date of such alterations,and a speck description of the alteration. Mat1 9 ituck, New York 11952 Mattituek, New York Date : 5-4-2007 (631) 298-1986