Loading...
HomeMy WebLinkAbout37679-Z r Town of Southold Annex 12/19/2012 ���SUEFot,�cd�� P.O.Box 1179 54375 Main Road oy • ��` Southold, New York 11971 CERTIFICATE OF OCCUPANCY No: 36094 Date: 12/19/2012 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 5290 ALVAHS LA CUTCHOGUE, SCTM#: 473889 Sec/Block/Lot: 101.-2-19.2 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 9/2/2008 pursuant to which Building Permit No. 37679 dated 12/10/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: additions and alterations, including deck, to an existing one family dwelling as applied for. The certificate is issued to Adam&Nicolle West (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37679 12/17/12 PLUMBERS CERTIFICATION DATED 12/12/12 J Whitecavage Autho ' ed Sigyrature ;�� TOWN OF SOUTHOLD 4�gUFE04„�co� BUILDING DEPARTMENT CO TOWN CLERK'S OFFICE SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 37679 Date: 12/10/2012 Permission is hereby granted to: ADAM WEST 665 GOOSE CREEK LANE SOUTHOLD, NY 11971 To: ADDITION &ALTERATION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR.REPLACES EXPIRED B.P. # 34128 At premises located at: 5290 ALVAHS LA CUTCHOGUE SCTM # 473889 Sec/Block/Lot# 101.-2-19.2 Pursuant to application dated 9/2/2008 and approved by the Building Inspector. To expire on 6/1012014. Fees: PERMIT RENEWAL $91.95 Total: $91.95 I 4"If Building Inspector FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 34128 Z Date SEPTEMBER 2, 2008 Permission is hereby granted to: ADAM WEST 5290 ALVAHS LANE CUTCHOGUE,NY 11935 for ADDITION & ALTERATION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR. THIS BP# REPLACE 'S 32212 at premises located at 5290 ALVAHS LA CUTCHOGUE County Tax Map No. 473889 Section 101 Block 0002 Lot No. 019 . 002 pursuant to application dated SEPTEMBER 2, 2008 and approved by the Building Inspector to expire on MARCH 2, 10 . Fee $ 183 . 90 A riz d S gnature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32212 Z Date JULY 14, 2006 Permission is hereby granted to : ADAM WEST ' Wt C al`6 5290 ALVAHS LANE CUTCHOGUE,NY 11935 for ADDITION & ALTERATION TO AN EXISTING SINGLE FAMILY DWELLING AS APPLIED FOR at premises located at 5290 ALVAHS LA CUTCHOGUE County Tax Map No. 473889 Section 101 Block 0002 Lot No. 019 . 002 pursuant to application dated JULY 10 , 2006 and approved by the Building Inspector to expire on JANUARY 14, 2008 . Fee $ 183 . 90 ! Authorized Signature ORIGINAL Rev. 5/8/02 Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY - This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings, property lines,streets,and unusual natural or 1 topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building,industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and"pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building$50.00,Additions to accessory building$50,00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 - 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy- Residential $15.00, Commercial $15.00 Date. New Construction: Old orr Pre-existing Building: N/- (check one) Location of Property: Iti l V q 14 S ` Li4 CUT tL_2 House No. Street Varnlet Owner or Owners of Property: ��LlZru„1 Suffolk County Tax Map No 1000,Section ® / Block I;z Lot //,:;7, Z Subdivision Filed Map. Lot: Permit No. Date of Permit. 42110 /'�'- -Applicant: «� S -'�- Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Ba Fee Submitted: $ J � Applicant Sign ure Vj r so�ryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 iQ roger.richert(aD_town.southold.ny.us Southold,NY 11971-0959 COUNV,� BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Adam West Address: 5290 Alvahs Ln City: Cutchogue St: NY Zip: 11935 Building Permit#: 37679 Section: 101 Block: 2 Lot: 19.2 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: RJ Corazzini Electric License No: 33419-me SITE DETAILS Office Use Only Residential. X Indoor X Basement Service Only Commerical Outdoor 1st Floor Pool New Renovation 2nd Floor X Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 10 Ceiling Fixtures 2 HID Fixtures Service 3 ph Hot Water GFCI Recpt 1 Wall Fixtures 3 Smoke Detectors 3 Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors 1 Sub Panel A/C Blower Range Recpt Fluorescent Fixture 1. Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect Switches 12 Twist Lock F1 Exit Fixtures TVSS Other Equipment: 1-paddle fan, 1-exhaust fan Notes: Inspector Signature: Date: Dec 17 2012 81-Cert Electrical Compliance Form.xls Town Hall Annex Telephone(63.1)•765-1902 54375 Main Road Pax(631)765-9502 co P.O.Box 1179 Southold,New York 1.1971-0959 CO(1NTY, BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFI_CA,TION Date: / Building Permit No. 7 Owner: fT (Please print) Plumber: ©2 rd Q vie c (Please print I certify that the solder used in.the water supply system contains less.than 2/10 of 1OX. lead. . lumbers Signature)'*. ,.,. Sworn to before me this day of 2012, Notary Public, tY CNRISTIE Hi1LLOCK Notary Public,State of New York .4831950,Suffolk Counter 1 Expires,May 31,20.'�.7 OF SOUryolo courm,ti�' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [XROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION FRAMING STRAPPING [ ] FINAL [ ] FIREPLACE A C Y [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: 9±!�� I 01, DATE �� �� INSPECTOR SOUI,�olo coummm TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: C9 DATE J I ��� ® g INSPECTOR _ riE SOpT�o� cOUNiY,N TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION ' . [ ] FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] IN LATION [ ] FRAMING/STRAPPING [ INAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: OL L�2 c- DATE �� �� INSPECTOR pf SO�jyo�o A\ c0UH1`I,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION .' [ ] FOUNDATION 1ST [ ] ROUGH PLBG. - [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY. [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ELECTRICAL (FINAL) REMARKS: DATE INSPECTOR INSPECTION REPORT DATE COMMENTS �h FOUNDATION(1ST) ------------------------------------ FOUNDATION (2ND) � • o ROUGH FRAMING& H PLUMBING 1, Ll t r INSULATION PER N.Y. STATE ENERGY CODE FINAL ADDITIONAL COMMENTS ! o 2� C" O - O z X O x E� H • x • C �d �3 TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL ' Board of Health SOUTHOLD;NY 11971 4 sets of Building Plans TEL: (631) 765-1802 � . Planning Board approval FAX: (631) 765-9502 Survey www. northfork.net/Southold/ PERMIT NO. 2�/ Check Septic Form N.Y.S.D.E.C. q Trustees Examined f ,20p Contact: Approved ,20_0_9 Mail to: Disapproved a/c i Phone: Expiration 120 O ` Building Inspector JUL APPLICATION FOR BUILDING PERMIT Date 7 S" , 20S INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing, the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) 0q1%G110 AVWVA5 I-chc C.�. \-11a&v<- NY, (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises xoal� W e_ Vk C- e- W eS� (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) 1 � Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Locatio of land on which proposed work will be done: Sad N� hw� �on� �u ��^" "� House Number Street Hamlet County Tax Map No. 1000 Section (� 1 Block gb&Lli3RYa; . ,� 01��J 6fatt r,.0641VOL, Subdivision Filed Map No. fox WIFS (Name) p" 2. State existing use and occupancy of pr mises and 1\inteNded use and occupancy of proposed construction: a. Existing use and occupancy e'4 - t a b. Intended use and occupancy ire S 1 ke , 3. Nature of work(check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost � on o Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type pf use. 37, t r f I 7. Dimensions of existing structures, if any: FrontRear ' epth Heightr` Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories Q, 8. Dimensions of entire new construction: Front Rear 1�C---c- Depth 7, 0 Height ^ 01 Number of Stories r) 9. Size of lot: Front � Rear Depth 10. Date of Purchase > cA' ,- o oO Name of Former Owner C`^`'s �p�, F` y&,h 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO o Will excess fill be removed from premises? YES NOX 5ago�1.y'OLFIS LAMC 14. Names of Owner of premises l le Address C- �°Vle- Ny 119 3s Phone No. �3 --739 —9a 11 Name of Architect Y10 �� Cl-�(� n�_T Address Phone No 417— 61-too Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES—NO * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF�G�(L MG'V_' west being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the © W (Contractor,Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this day of `j— 20_ok_An Notary Public RJ Signature of Applicant Mlrly swW�R York - ��oF s�►Uryo Town Hall Annex 4 Telephone(631)765-1802 54375 Main Road (631)765-g ffi P.O.sox 1179 G Q roger.richert(c 0 n.southattl.ny.us Southold,NY 11971-0959 V �ti BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: /�S o� �p�r�Z,�, e Date: / l 3 l Z— Company Name: Name: License No.: Address: Phone No.: z;�,7l— 33 .5-- e919/9 Z JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: *Cross Street: Z$' *Phone No.: 311- Permit No.: J,7 z Tax-Map District: 1000 Section:_/D Block: a Lot: ) a *BRIEF DESCRIPTION OF WORK(Please Print Clearly) �esr a u (Please Circle All That Apply) *Is job ready for inspection: / NO Rough In F na *Do-you need a Temp Certificate: YES! NO Temp Information(if-needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION C, .82-Bequest for inspection Form tA t pF SO!/lyOlo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 Ol • �O y1001 BUILDING DEPARTMENT TOWN OF SOUTHOLD December 12, 2012 Adam West 5290 Alvahs Lane Cutchogue, NY 11935 TO WHOM IT MAY CONCERN: The Following Items Are Needed To Complete Your Certificate of Occupancy: Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. (contact your electrician) _ A fee of$50.00. Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. (Planning#765-1938) Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. Final inspection by Building Dept. BUILDING PERMIT : 37679-Z addition/alteration l9.ZTOWN OF SOUTHOLD PROPERTY RECORD CARD /000 - n / - ,1 • OWNER. STREET r-ti VILLAGE DIST. SUB. LOT FORMER OWNER N E ACR. —LS/�C(GtCS Flp'-ynn /� J S/ W # TYPE F BUILDING /-� IV Y f� 6. k/v 7 P'l/ f� J. 1- 1 i:✓' +'Cr'R..f l_..i't� " f4 $...jy RES. / o i SEAS. VL. -'FARM'' COMM. CB. MICS. Mkt. Value LAND IMP. TOTAL DATE REMARKS. Z✓ /OCr' 4 71 a r- •• ' .l f2 is (/ . G 1 Za ?P�� �y 7 6, t1 , g f � 7 �, o ea ,� '2/ .3 0 77 o z.D �3.3 d oa ov = w s � f r E o 73. T :A d �-W ,tLz Jca .3laQv r� o 6 IIJI' j' ' ' -- �� — / .><,SS aC•5 Ta Ss s ac s � �/L "�' LAC �. k �--/l 7z/6 Yet se-k a � Uta - �' L I It eq3 - a 5 60,0 Tc�T 8 iog- L►aa q -F 64 - 5�p3,s6n AGE BUILDING CONDITION NEW NORMAL . BELOW ABOVE FARM Acre Value Per Value Acre Tillable tat y J FRONTAGE ON WATER Woodlan d J °`� . z FRONTAGE ON ROAD / z � �.. Meadowland �1 Z op° DEPTH House Plot GICy L �Z� BULKHEAD Total I DOCK MEN • 41 ;:� t k P q C.■...■...........■.....■.... ���� ■ ■eee■se■■e■■■■■■■■■■e■■■■■■ ♦ � . . ■ ■eeee■■eee■eee■■eeee■■■■■■■ ■■eeeee■■■■■■■■■■■■N■ ■■■ ■■ \� rho-,r,~ �, i, r ' �j ' ° ■■■■e■■■■■■■■■■■■■■■■ ■■■■■ ■■e■■ee■ee■■■■■■e eeeee ■■■■■ ■■eeeee■■I■■N■■ N ■eee■EMNi■i } ■■■eeee■�.. ©�,..e■eeeene■N■■ MEN �■■■■■ee©Ne®■ee��e■ee■N■N ■■■■■■■■■■■■■■MM■■■■■■N■■■■■■ - ■■■ease.■■■■■■��■■e■■e■n■■■■■■ : .. ■■e■■■■�■■e®■®■■■■■■e■e■■■EM ■NNNee■■NN■■■ee■EMI NN0■■■■■ ■■eeeee■eeeeeeeeeee■eeeee■■ Basement .. Fire Place • SURVEYF`PR P, R-TY re A T CU`T QG t ro.wN OF SOUT40LO 11 o SUFFOLK ��. OUNTY: N. Y PG 2 c� 1000 -�r©:� 02 - P10 -a �5csle: 1"- 60' c1� 20 April 30, 2003 G-11- �O,` 40 520 A3 o 00 - ti ne L ti 252,v � . R. p h CERTIFIED TO: 1 ►" INDY MAC BANK y . �� `�• J CHRI•STOPHE T FI_ YrN �Qe 6�� STtWART TI, (_ INSURANCE' COMPANY 5g 5 . 00 NEW), p. -P' F3e,r ANY.ALTERATION OR,400M0"N TO THIS SURVEY IS A VIOLATION \ ?OF SECT/ON. T209 OF THE Nvo, YORK STATE EDUCATION LAW. EXCEPT AS PER SECTION 7209 - SUBDIVISION 2. ALL CERTIFICATIONS hsl£REON.ARE VALID FOR THIS Mi4P AND COPIES THEREOF ONLY IF �O. �� : ` ► S. LIC.. 496I8 ` SAID MAP OR COPIES BEAf;7HE IMPRESSED SEAL OF THE SURVEYOR 6 LOT NUMBERS- A-RE REFERENCED. TO "CLUSTER SET-OFF FOR —� WHCSE SIGNATURE APPEA &REON, - BRUCE ISAAC$ PE CO s, P.C. ADDITIONALLY TO COMPLY W.'TH SAID'LAW TERM ' ALTERED BY ' (631) 765 - FAX (6 31) .765 — 179 MUST BE USED BY ANY AND ALL SURVEYORS UTILIZING A,COPY P. O. BOX 909 OF. ANOTHER SURVEYOR'S MAP. TERMS SUCH " INSPECTED ' AND r �: '-BROUGHT - TO - DATE `ARE NOT IN COMPLIANCE WITH THE LAW. �* l23O TRA VELEF STREET T AREA =: 1� 796 ACRESpuTHOLD, N.Y. 11971 ENERGY CODE CALCULATIONS CHAPTER. 5 SECTION 501 Detached One and Two Family Design Criteria 5750 Degree Days (For Non-Electric Heat) Zone 11B For: d q A l.Je.S Per: t0e.1 A,, c / v 4�s Cq t if e- ,S y t . Dated: 7R 2 n sus•, ,��I���� . SUBSYSTEM AREA DESIGN CODE DESIGN CODE "U" "U" UA UA Exterior Walls 7'L d.Oct 8 0.14 6. /�{ l3 �� 0 Ceiling Roof /Z 46 v, 0.30 0.031 3 6?, 8 0 4vo. / Floor Over Unheated Space q 13 0. 0 !( 0.05 2 tit J Heated Slab On Grade 6.5 Unheated Slab On Grade 4.5 Basement Wall 0.1 Crawl Space Wall 0.06 12-7, �` 2 r78 .6� NOTES: Construction shall comply with 502.1.1 moisture control and 502.1.4 air leakage Building Envelope Systems to meet requirements of Section 501 The mechanical systems and equipment including: HVAC Equipment,HVAC Systems,Duct Systems,Ventilation Systems and Insulation of Piping Systems to meet requirements of Section 503 Service Water Heating Systems &Equipment to meet requirements of Section 504 Electrical&Lighting Systems&Equipment to meet requirements of Section 505 /� NEW� .G1* O � c� To the best of my knowledge, v belief, &professional judgement, . e32srr9.1 these plans are in compliance p9o�tss�o * � with,the code. v 0 � t 1 O t � 2 3 i W cc 9 o -v: _. a rn �. uJ W *' tMo ,,_ ♦ cc x o _..__. ........... W o cf) P JMBING `" I` ALL P IMBING WASTE LI &WA R LINES NEED = TESTING :,:FORE COVERING — PLUMBS ERTIFICAT/'�IV. ON LEAD LATENT -. -ST�f - -- - CERTIFICA 0. Y - - - - — LDE Stu ,: E1c,� Lam. V ! L:j' ,FFn /10 OF 1°o.L.�AD. I I THE EC1U1r?tME ll__TS F THE C 6 DES OF NEW YORK 8 ATE. o; CERTIFICATION �F Y '� �' uc a AWFUL -. NAILING & CONNECTIONS �'•a.,++° O • � I AFr �i'�OVED A� NOTED ,, • REQUIRED. DATE:,_ B.P.t� • � �� CERTIFICATE .. I • _� �, _ LACY _ --- - --- FEE: � � ` -E3-Y: � � .�PA NOTIFY BUl4_DING DEPARTMENT AT - --` 765-1802 8 AM TO 4 PM FOR THE JI , FOLLOWING INSPECTIONS: '�• 1. FOUNDATION - TWO REQUIRED _..._! FOR POURED CONCRETE -- l� _�_C:�� -` _t��V 'R3 r:I aF «EIV 2. ROUGH - FRAMING & PLUMBING AGE T Qq W 3. INSULATION ? ` * �`" Ly 4. FINAL - CONSTRUCTION MUST BE COMPLETE FOR C.O. �' W ALL CONSTRUCTION SHALL MEET THE I a REQUIREMENTS OF THE CODES OF NEW RETAIN STORM WATER RUNOFF2 � YORK STATE. NOT RESPONSIBLE FOR PURSUANT TO SECTION 45-10C affssl0�h DESIGN OR CONSTRUCTION ERRORS. OF THE TOWN CODE, - ^ p 1, . U. 1 0 V-DERWRiTERS CERTIFICATE W REQUIRED a y 0 �t Z 3 J W O uj to O m N j C co I- 119 O a z chi q W T c� W T a0 _ F-71 i -- I { 11 I - � O c' A�.. ��. LL LLJ o Q N 10 J C O e o - 0 z 3 EkC�Tixt� fr�rs�z n I O lam' i '�-l2"-X4 So►Jo't�B� =� � Z � (.'f Y P r c AID �! _ W r eh ID x _ t a � k�/� �� - - --- V2.�r.c�klt2 ADD 13/ ;o o s.�—crlvw a Ew �k t st _J Nf -- Cis �Nf w.__ 6/'Ck ��'`=�=- ( W o z z �f p cc, �K - -t�tE �� _�ar�►�c S New Z r COL lh i i (TYPi c A L-.3)- , I rcr W oA90ff'SSI �� LL 0 W N 10 O J 7 A ' J 2 Q Q LU LLI 1 11 A N 7'irCVaL k y �kl CID �*` ► c i� ' Lo m o �`' ! p r. -- ��tir �1LU f o� x III��'c"-���-- � ti •o �, I I c� Y a a d � Z -T aAt�r� o � Z- o Urfa 6 - Q p � Sit Fe -- � M co �xI V kj W ?J' 03 254-1 C x c STi R sr ca _ A9Of[SS1aN��� / L- 0 W 0 N V''^^ IO A 0 4 � g c 0 alga a � r . 3L4 -ter" F v ji- o Go IL 0 �7 -441 W r r W oc x �- a \ rq l Y LL 0 ,. O 9 /V-Au(-Y ,"- ,�� �J oPC�I Fvz-op-", lbf_!o r /4 !'0 uj Lu V A9Q �"5S10 0� LL O c Qro Of CL e r 0719 O O C7 ZLU J W S 1 Q — � -ttrlN 'ArIfn _1z .-Root u►JI ir `' a •1 t.I A LET-r t _. _ co r O / cr. 2 z.X-r 1 _2. 2y!, tb�(f- ; ,�` �" z o, - _ � _ w V cc x U #-r t-I �l le",C_T,� cc LU l�ft~C�� ti6Fz56 _s � I _ e 'SS-AS IST pia LSD/£rL PCB oara j — 1' _ _ �`�!--�.^G_--�.�5�-�DTI-►`Ct Z)C'�j V(�1�1{�L� (���� Y---ZK — r1 -t _ I�`�-- J _ V um —_..--- -- -- - ---------- " Ar ( S, .tZ".�.IZ:/y'-p�►A�flfrolL FooTlin[C;s / ..-f �' ki e�� L LL N GENERAL CONSTRUCTION NOTES GENERAL FRAMING NOTES 1.The information on this set of construction documents is to relate basic design 1.All walls,2x4 and 2x6,to be stud grade or better 16"o/c. All other framing material NAILING SCHEDULE intent and framing details. They are intended as a construction aid, not a substitute to be#2 douglas fir or better. for generally accepted good building practice and compliance With current New York TABLE 3.1, INCLUDING 3.3 AND 3.9 state building codes. The general contractor is responsible for providing standard 2.All wood framing in contact with concrete or masonry to be pressure treated. 1995 SBC HIGH WIND EDITION WOOD FRAME CONSTRUCTION MANUAL construction details and procedures to ensure a professionally finished,structurally JOINT DESCRIPTION NAIL QUALITY NAIL SPACING sound, and weatherproof completed product. 3. Provide double floor joists under all walls parallel to floor joist span direction unless otherwise specified. ROOF FRAMING � RAFTER TO TOP PLATE TOE NAILED 8'-0" WALL: 3-8d PER RAFTER (n 2.General Contractor to coordinate all sub contractors, scheduling of work,and 10'-0" WALL: 4-8d PER RAFTER Z interaction between trades. 4. Provide x-bracing or solid blocking at a maximum of 8'-0"o/c for all dimensional CEILING JOIST TO TOP PLATE TOE NAILED 8'-0' W A L L: 3-8d PER JOIST lumber floor joists. 10'-0" W ALL: 4-8d PER JOIST 1< �o CEILING JOIST TO PARALLEL RAFTER FACE NAILED SEE TABLE 3.7 EACH LAP UJ 3.The general contractor is responsible for ensuring that all work and construction CEILING JOIST LAPS OVER PARTITIONS FACE NAILED S E E TABLE 3.7 EACH LAP 2 $- meets or exceeds current federal, state, and local codes,ordinances and regulations, 5. Floor construction:%"tongue and groove plywood subfloor. Finished material to be COLLAR TIE TO RAFTER FACE NAILED s E E TABLE 3.4 PER TIE to 0 etc. These codes are to be considered as part of the specifications for this building applied over subfloor. Glue and screw plywood decking to floor joists. BLOCKING TO RAFTER TOE NAILED 2-8d EACH END i0- �U) and should be adhered to even if they are in variance with the plan. RIM BOARD TO RAFTER END NAILED 2-1 6 d EACH END 0 Q U' 6.All window and door headers to be minimum(2)2x10 unless otherwise specified. WALL FRAMING 0i � 4. Dimensions shall take precedent over scale drawings(do not scale drawings). All interior headers to be(2)2x10 unless otherwise specified. TOP PLATE TO TOP PLATE FACE NAILED 2-1 6 d PER FOOT ,.i TOP PLATES AT INTERSECTIONS FACE NAILED 4-16d JOINTS - EACH SIDE I" Y STUD TO STUD FACE NAILED 2-16d 24" O/C 5.The designer has not been engaged for construction supervision and assumes no 7. Provide full solid blocking under all bearing walls. HEADER TO HEADER FACE NAILED 1 6 d 16" O/C ALONG EDGES responsibility for construction coordinating with these plans, nor responsibility for TOP OR BOTTOM PLATE TO STUD END NAILED 2-16d PER 2x4 STUD I ~ construction means, methods,techniques,sequences,or procedures,or for safety 8.All beams to have adequate bearing at each end or as specified. 3-16 d PER 2 X6 STUD precautions and programs in connection with the work. There are no warranties for a BOTTOM PLATE TO FLOOR JOIST, 4-16d PER 2X8 STUD specific use expressed or implied in the use of these plans. 9.All flush beam and joist intersections to have galvanized hangers. B A N D J O IS T, END JOIST, OR BLOCKING FACE NAILED 2-1 6 d - PER FOOT ti 6. Refer to floor plans,exterior elevations,and window schedule for types and sizes of 10.Typical exterior walls and roof to be sheathed with Y2'exterior grade plywood or JOIST FLOOR OF RSA M I G V7 TOP PLATE, OR GIRDER TOE NAILED 4-8d PER JOIST 'y windows. All windows to be Andersen high performance quality or approved equal. 7/16"OSB plywood,group 1,APA rated. Plywood to span over all plates and BRIDGING TO JOIST TOE NAILED 2-8d EACH END headers. BLOCKING TO JOIST TOE NAILED 2-8d EACH END 7. Door and window headers to align unless otherwise noted. BLOCKING TO SILL OR TOP PLATE TOE NAILED 3-1 6 d EACH BLOCK LEDGER STRIP TO BEAM FACE NAILED 3-16d EACH JOIST 11. Provide insulation baffles at eave vents between rafters. JOIST ON LEDGER TO BEAM TOE NAILED 3-8d PER JOIST 8.General contractor is to ensure that masonry and prefabricated fireplace BAND JOIST TO JOIST END NAILED 3-16 d PER JOIST J construction meets or exceeds all manufacturer's specifications and applicable codes. 12. Exterior flashing to be correctly installed at all connections between roofs,walls, BAND JOIST TO SILL OR TOP PLATE TOE NAILED 2-1 6 d PER FOOT 14 chimneys,projections,and penetrations as required by approved construction ROOF SHEATHING � •"' 9. General contractor to consult and coordinate with the owner and the plans for all practices. STRUCTURAL PANELS 4' P E R IM E T E R EDGE ZONE - 16" O/C - 6" AT PANEL C Z built in Items such as bookcases, shelving, pantry,CIOSetS,etc. EDGES AND AT INTERMEDIATE SUPPORTS IN THE J 13.General contractor to provide adequate attic ventilation and roof vents. I 8d PANEL FIELD E- INTERIOR ZONE - 16" O/C - 6" AT PANEL EDGES AND 12" 10. Provide hardwired smoke detectors,with battery backup,on all floors and in each I^I 8d AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD bedroom,verify with local code requirements as per Section R317, New York State 14. Provide appropriate soffit ventilation at overhangs. FOR ROOF SHEATHING WITHIN 4'-0" OF THE PERIMETER EDGE OF THE ROOF, INCLUDING 4'-0- ON EACH SIDE OF THE ROOF PEAK, THE 4'-0" Residential Construction Code. Install carbon monoxide detectors as per Code. GENERAL PLUMBING NOTES PERIMETER EDGE ZONE ATTACHMENT REQUIREMENTS SHALL BE USED. CEILING SHEATHING GENERAL FOUNDATION NOTES 1. Plumbing subcontractor to be responsible for adhering to all applicable code and GYPSUM WALLBOARD 5 d COOLERS 7" EDGE/10" FIELD safety requirements. WALL SHEATHING F- 1. General contractor to review plans, elevations,and details to determine intended STRUCTURAL PANELS 8d 4' E D G E ZONE - 16" O/C - 6" AT PANEL EDGES AND 12" IY ti heights of finished floor(s)above typical grade. 2.If wall plates or joists are cut during the installation of plumbing fixtures or AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD O LO 8d INTERIOR ZONE - 16' O/C - 6- AT PANEL EDGES AND 12- I1 0 equipment provide bracing to tie framing back together. AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD Z ~ 2.All footings to rest on Undisturbed soil. FIBERBOARD PANELS z/1 6"GENERAL HVAC SYSTEM NOTES 8d 3" EDGE / 6" FIELD LL.) I 3. Provide%"expansion joint material between all concrete slabs and abutting GYPSUM WALLBOARD 5 d COOLERS 7" E D G E / 10" FIELD � CO concrete or mason walls occurring in exterior or unheated interior areas. 1. Mechanical subcontractor is responsible for adhering to all applicable codes and T 6 d a' EDGE ZONE_- 1 6" o/c - 6" A T PANEL EDGES AND 12- (� �- c0 masonry 9 P 9 PP 1 HARDBOARD AT INTERMEDIATE SUPPORTS IN THE PANEL FIELD safety requirements. 1995S®CHGH\N DEDITICNV�CMR:1ANIE CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA 0 > o 4. Concrete on 4"sand or gravel fill minimum,with 6x6-10/10 wire mesh reinforcing. OCNSTFUMN MA►uYaL WEATHERING SEVERE Q Z Interior slabs to be placed on 6 mil. stabilized polyethylene vapor barrier. 2. HVAC subcontractor to fully coordinate all system data and requirements with the O o equipment supplier. RAl-�FRSPA(�I�16'C✓C ti FROST LINE DEPTH 3'-0" 5. Provide crawl space ventilation per local code requirements. TERMITE MODERATE TO HEAVY Z r- 3. HVAC subcontractor to provide final system layout drawing and submit it to general' ROW PrMH ROWSPAN DECAY SLIGHT TO MODERATE Q 6. General contractor to install cop-r-tex(or copper)sheet metal termite shields contractor,owner,and equipment supplier for final review and approval. 12 20 28 36 WINTER DESIGN TEMP. 11 cr) between all wood surfaces that are exposed to concrete or masonry surfaces. a12 5 8 11 1 C° ICE SHIELD UNDER- AS PER MANUFACTURERS 7. Dampproof exterior of foundation with a bituminous coating as per code and soil NEW CODE 41- - 4. 6 8 11 LAYMENT REQUIRED SPECIFICATIONS / STATE CODE FLOOD HAZARDS conditions. GENERAL WIND PROTECTION CONNECTION NOTES 5.1 7 Adapted from Standard for Hurricane Resistant Residential Construction;SSTD 10-99 7.1 and 1995 SBC High Wind Edition Wood Frame Construction $1 4 GENERAL_ FLOOR PLAN NOTES_ Fasteners and Connectors for Wood Frame Construction 1. Dimensions shall take precedent over scale drawings(do not scale drawings). 1.A continuous load path between footings,foundations walls,floors, studs and roof 121 SOUTHOLD BUILDING DEPARTMENT CRITERIA framing shall be provided. 1 OCCUPANCY CLASSIFICATION R-3 RESIDENTIAL-SECl10N 310 BUILDING CODE N.Y.S. 4 USE DWELLING UNIT-SEC11ON 310-310.2 t , 2.All interior walls to be covered with%"gypsum board with metal corner reinforcing. TABLE 3. Tape,float,and sand(3 coats). 2.Approved connectors,anchors and other fastening devices not included in the 1995 SBC HIGH WIND EDITION WOOD 2 HEIGHT 2'-I -,-" Standard Building Code,Table 2306.1 shall be installed in accordance with FRAME CONSTRUCTION MANUAL FIRE AREA RAFTER SPACING 16" O/C (s� / io SQ. FT. TOTAL 8`f E kl S'r (oS2 � 3.Walls common to garage and house to have a layer of 5/8",fire rated gypsum board manufacturer's recommendations. 120 mph FASTEST W INDSPEED 3 TYPE OF CONSTRUCTION WOOD FRAME CONSTRUCTION W at garage side With 5'-0"return on adjacent walls and ceiling. Manufactured lumber 4 DESIGN CRITERIA PRESCRIPTIVE DESIGN-1995 HIGH WIND EDITION WFCM I . ~ requires 2 layers of 5/8",fire rated gypsum board. 3. Metal plates,connectors, screws, bolts, and nails exposed directly to the weather oir ROOF ROOF NUMBER 5 FRAMING ELEMENTS SEE FLOOR PLANS AND SEC-PONS C kc '`o W subject to salt corrosion in costal areas, shall be stainless steel or hot dipped PP PITCH SPAN (ft) O F NAILS 6 DESIGN LOAD CALCULATIONS 5 t in C-H U+-f -rk i ,1 4.All bath and toilet area walls and ceilings adjacent to wet areas to have water galvanized. /�-c;� � resistant gypsum board, or wall tile set on wonderboard or equal. 4:12 12 3 7 WINDOW AND DOOR SCHEDULE -7 Z 4.Where windows and doors interrupt wood structural panel sheathing and siding, 26 5 8 LOAD PATH SEE SECTION"A" of DESIGN LOAD CALCULATIONS framing anchors or connectors shall be provided at the top and bottom of cripple 24 6 9 NAILING SCHEDULE A-6o J t- p studs, header studs,and at least one stud at each side of opening. 28 7 10 EGRESS Se 45 e6c.-e S O MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS Ibsf 32 8 11 PLUMBING RISER DIAGRAM F LLL EXTERIOR BALCONIES 6 0 5. Ridge straps shall be attached to each pair of opposing rafters except where collar 36 - 12 FIRE PROTECTION , -e_- 0 DECKS 40 ties of 1 x6 or 2x4 lumber is located in upper third of attic space and attach to each pailr 5:12 12 3 ►� ►� Z 16 a 13 TRUSS DESIGN DRAWINGS rr o 1,;&-u ss ....I Q ATTICS WITHOUT STORAGE 30 of rafters. 20 a 14 ENERGY CALCULATIONS /-r-r�c�ary ` W ATTICS WITH STORAGE 40 6. Uplift connectors shall be provided at each rafter bearing. 24 5 ROOMS OTHER THAN SLEEPING ROOMS 40 28 6 O SLEEPING ROOMS 30 7. Floor to floor hold-downs to be provided every 48,and every 16"within 4'of exterior 32 7 = comers. 36 7 CRITERIA FOR CALCULATION OF DEAD LOAD 6:12 12 3 PL� ACTUAL WEIGHTS OF MATERIALS REFERENCED TO A.I.A. 8. Sill Plate to Foundation Anchorage: Sill plate shall be anchored to the foundation 16 3 ARCHITECTURAL GRAPHIC STANDARDS With anchor bolts having a min. bolt diameter of 5/8"and 3"x 3"x 1/8"washers. A 20 a minimum of one anchor bolt shall be provided within 6 to 12 inches of each end of 24 5 SNOW each plate. Anchor bolts shall have a minimum embedment of 7 inches in concrete/ 28 5 �. GROUND SNOW LOAD 1451bs. 32 6 masonry foundations. Anchor bolts shall be located within 12 inches of comers and at 36 7 spacing not exceeding 4 feet on center. 7:12-12:12 12 2 SEISMIC 16 3 f . DESIGN CATEGORY 113 20 4 WIND THESE NOTES ARE GENERAL CONSTRUCITON NOTES. THEY ARE NOT 28 s yA SPECIFICALLY WRITTEN FOR THIS PLAN. THEY ARE TO BE CONSIDERED AS W IND SPEED 120 m h 32 s 032254•1 � EXPOSURE CATEGORY 113 GENERAL GUIDELINES ONLY AND SHOULD BE DISCUSSED WITH YOUR 36 6 GENERAL CONTRACTOR BEFORE CONSTRUCTION BEGINS. 94FUS►10% b G cr- t n n. a0 n. i o RIDGE - - ----- ---- Q IllRAFTER p 01 r ww Z I�, USP RS250 AT 21 'Q r h A ` RAFTER/RIDGE/RAFTERwITHcT _�i --- - -- — -- - -- RAFTER KING STUDS 3, RIDGE RAFTER zl STUD i �� � � USP RT16 OR(2)RT7------ - -- Z; RAFTER — HEADER -� TOP PLATE -- O TOP PLATE USP RS250 AT 21 USP RT3 j USP RT20 USP RS250 AT 18" — o USP LS OR TMU IES WALL STUD WALL STUD USP RS250 AT 12" - CONNECTION USP PRODUCT NUMBER JACK STUDS A RAFTER/RIDGE/RAFTER WITH CT• RS250 21" J RAFTER/RIDGE/RAFTER WITHOUT CT RS250 21"+LSSH179 I Sr ► B RAFTER/PLATE/STUD RT20 RAFTER/PLATE RT16 or(2)RT7 PLATE/STUD RS250 18" (__A1_' RAFTER/RIDGE/RAFTE-Rw/ocr__ B RAFTER/PLATE/STUD _ B RAFTER/PLATE PLATE/STUD C HEADER/STUD RT3 --- - _ — . C�HEADER/STUD HEADER/JACK w<— - — - - - -- l_ — - —— — HEADER/JACK STUD RS250 12" CO —� --- D FLOOR TO FLOOR KLFTA or RS250 36" 0 LO E STUD/PLATE/SILL RS250 36" a O STUDIPLATE RS250 16" W PLATE/SILL MP6F W F ANCHOR BOLTS STB16 M G POST ANCHOR FOR DECKS PAU SERIES 0 CO POST ANCHOR FOR COVERED PORCHES CBE SERIES 0 O 1X6 OR 2X4-16"O/C COLLAR TIES MIN. 0 Z O z M POST USP CBE P.C.FOOTING 2ND.FLOOR WALL STUD 2ND.FLOOR WALL STUD 1ST.FLOOR WALL STUD--- - 1ST.FLOOR WALL STUD--- 2ND.FLOOR PLATE— 2ND.FLOOR PLATE SUBFLOOR SUBFLOOR G `�POST ANCHOR FOR COVERED PORCHES_ W 1ST.FLOOR PLATE- 1ST.FLOOR PLATE I RIM BOARD Q RIM BOARD DOUBLE SILL PLATE SUBFLOOR SUBFLOOR Z USP KLFTA USP RS250 AT 36" W USP RS250 AT 36" USP RS250 AT 16"RIM BOARD RIM BOARD U 1ST.FLOOR TOP PLATES - 1ST.FLOOR TOP PLATES Z -- - -- "- DOUBLE SILL PLATE POST USP MP6F 0 1ST FLOOR WALL STUD 1ST FLOOR WALL STUD FOUNDATION WALL FOUNDATION WALL USP PAU P.C.FOOTING Z L D 1 FLOOR TO FLOOR D FLOOR TO FLOOR E )STUD/PLATE/SILL E `)STUD/PLATE PLATE/SILL G _``�POST ANCHORS FOR DECKS �� PL� 4 UJ r a`' 6y 0322 V 9QFiRS 1 * / I� �G W I_l_ e STRUCTURAL WOOD PANELS FOR WIND-BORNE DEBRIS PROTECTION t WINDOW AND DOOR SCHEDULE FOR I ; WALL OPENING PROTECTION OF120 MPH 3-SECOND WIND GUSTS (MAXIMUM MEAN ROOF HEIGHT:35) a o :r 4 'i. • A Ian :-(a...cii'.'+,.s"iLs�+..,; _ .'s', - .y::, _ 3 '' ' x. -.,d • � � J .,�� aF^, T `i �'- .,r+•" t.• .� �ri -i+ MULTIPLE SECTION ASSEMBLY: 1/4" THICK BOLTS @ 2'OC /l p,�.ll '� /�nl*J'<SG r1 }{ /�. ►�/r+ C J U r� {_ cn I ' j (t,Y ✓1��CNn�T lJ g �, /,, ) ! 2 (yr D Z CXI I'C,r{.ss hi-I .a lT �, 90 r�, o lj D . 3 �1.� Zo 2 ''.; `� �P � v liz° I^ w I� la !ifl' I�I 4I ALL WINDOWS TO BE ANDERSEN HIGH PERFORMANCE OR APPROVED EQUAL II !CALCULATIONS FOR WINDOWS BASED UPON EXPOSURE B MUST HAVE DP UPGRADE KIT. i COEFFICIENT 1.10 WITH 120 mph BASIC WIND SPEED. AS PER E MEETS NY STATE EGRESS IL i t I ESS REQUIREMENTS n TABLE R 301.2 (2) NEW YORK STATE BUILDING CODE. - -� :FOR HABITABLE SPACE. CUSTOM GRILLES SEE ELEVATIONS I !WALL OPENINGS INCLUDING WINDOWS AND DOORS SHALL BE PROTECTED WITH REMOVEABLE 5/8" WOOD STRUCTURAL PANELS IWITH MAXIMUM OF 8'-0" SPAN. FASTENERS FOR SPANS UP TO 6'-0" SHALL BE 2 1/2 - # 8 WOOD SCREWS AT 16" O/C, FASTENERS FOR SPANS UP TO 8'-0" SHALL BE 2 1/2" - #8 AT 12" O/C. TABLE 301.2.1.2 iALL NARROLINE; WINDOWS MUST USE: 1/2" HEIGHT SILL STOP (OR STOOL) AND THE ADDITION OF A 1/2" X 3/4 DP UPGRADE SILL STOP. (SILL STOPS TOTAL A 1-1/4" ! ! j HEIGHT AND REQUIRE THE INSTALLATION OF A SPECIAL SASH LIFT INCLUDED WITH DP UPGRADE SILL STOP KIT.) ' I !�; > ALL UNITS MUSlf MEET OR EXCEED THE MINIMUM DESIGN PRESSURE REQUIRED, ANY MULLED UNITS MUST MEET OR EXCEED 11.5 TIMES THE DIESIGN PRESSURE REQUIRED AND MUST TRANSFER LOADS TO THE ROUGH OPENING SUBSTRATE. ALL EXTERIOR GLAZING MUST IMEETASTM E 1996 TEST REQUIREMENTS AS PER NEW YORK STATE RESIDENTIAL CONSTRUCTION CODE. ,REFER TO SECTION R 1609.1.4 FOR ALTERNATIVE OPENING PROTECTION. ! Ix r-- O a ti 1 w -4— TIER � ASSEMBLY 0 .— c� N.T. OR F� EL S ANS:0<4'-0"WIDE SPAN TABLE 1 .1.4 ) I ( p } o 23/32"APA S -RATED 48/24 SHEATHING GRADE PLYWOOD(OVERLAP AR OPENIN S 4") 1'/t ( � 0 G USE AC GRADE W OATS EXTERIOR PAINT 2 SIDES,4 EDGES. LABEL ACCORDING OCATION. / IIASSEMBLY: +. to ATTACHING STRUCTURAL P L: FASTEN TO BUILDING will#84" w/WASHERS)GALVINIZED OR ' STAINLESS STEEL WOOD SC @ 16"O.C.OR BETTER ALTERNATIVE FASTNER FOR SHU TO BUILDING: _ #10 TEE NUTS ATTACHED TO BLDG.w x 1 Yz^(W SHERS)MACHINE BOLT @ 12"O.C. - I¢M f WHERE SCREWS ATTACH TO MASONRY 0 RY STUCCO,THEY SHALL BE ATTACHED UTILIZING VIBRATION RESISTANT ANCHORS ING A MINIMUM WITHDRAWL CAPACITY OF 490 Ibs. SIT SY rl c SHUTTER ASSEMBLY � J�Y +� N.T.S. `I T I cf) -0 FOR PANEL SPANS:4' "OR WIDER- AN I I _ _ �-_-. .I- ----1 ` L -� Of W � .�.. I; L1 I!•�ti J SPECIFICATIONS AND ASSEM IDENTICAL TO 0<4'-0"SP Z ^� W NOTE ADDITIONS: O 2x4 STRONG-BACKS OC To �, .�. -4 Z ASSEMBLY: O 1). PREASSEMBL LYWOOD TO 2x4'S:# 10x3"(w/WASHERS)GALVINIZED TAINLESS STEEL O WOOD SCRE 12"O.C. U-W i�i z ALTERNATIVE FOR OPENING PROTECTION ZQ W WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16"AND MAXIMUM PANEL SPAN OF 8'-0" w SHALL BE PERMITTED FOR OPENING PROTECTION IN ON AND TWO STORY BUILDINGS. PANELS Q SHALL BE PRECUT TO COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED. (REFER TO SECTION 1609.1.4 AND 1609.6.5 AND TABLE 1609.1.4) i I;y TABLE 1609.1.4 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS , y rL, 9�- 41 ° a �► �i FASTENER SPACING INCHES t �- c"j ' PANEL SPAN <2' 2'•0"< PANEL 4'-0"< PANEL 6' "< �t Y . w FASTENER TYPE 0" -0 PANEL SPAN<4'-0" SPAN <6'-0" SPAN < 8'-0" 1e ��A 2 1/2" #6 WOOD SCREWS PLUMBING DIAGRAM :*2 -'1g 16 12 9 *� _ flsst ,.., 2 98 WOOD SCREWS 16 16 16 �-•—� C ----- ------- ' A.THIS TABLE IS BASED ON A MAXIMUM WIND SPEED (3 SECOND GUST)OF 130 MPH AND MEAN ROOF v `►- 1 HEIGHT OF 33'-0"OR LESS OJ B. FASTENERS SHALL BE INSTALLED AT OPPOSING ENDS OF THE WOOD STRUCTURAL PANEL. C. WHERE SCREWS ARE ATTACHED TO MASONRY OR MASONRY/STUCCO,THEY SHALL BE ATTACHED UTILIZING VIBRATION RESISTANT ANCHORS HAVING A MINIMUM WITHDRAWL CAPACITY OF 490 LBS. i ( 1 • f LL