Loading...
HomeMy WebLinkAbout37645-Z Town of Southold Annex 1/9/2013 ��p�g�FFDI,��oGy P.O.Box 1179 Coil� 54375 Main Road o Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 36105 Date: 1/9/2013 THIS CERTIFIES that the building SOLAR PANEL Location of Property: 160 Sailors Needle Rd, Mattituck, SCTM#: 473889 Sec/Block/Lot: 144.75-26 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 4/20/2012 pursuant to which Building Permit No. 37645 dated 11/27/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: Roof Mounted Electric Solar Panel System as applied for. The certificate is issued to Penney,Deborah (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37645 8/29/12 PLUMBERS CERTIFICATION DATED A ed Xignature ' TOWN OF SOUTHOLD �gU�FO�,y-c0 BUILDING DEPARTMENT TOWN CLERK'S OFFICE oy • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 37645 Date: 11/27/2012 Permission is hereby granted to: Penney, Deborah PO BOX 470 Mattituck, NY 11952 To: install roof mounted electric Solar Panel system as applied for At premises located at: 160 Sailors Needle Rd, Mattituck SCTM # 473889 Sec/Block/Lot# 144.-5-26 Pursuant to application dated 4/20/2012 and approved by the Building Inspector. To expire on 5/29/2014. Fees: SOLAR PANELS $50.00 CO -ALTERATION TO DWELLING $50.00 Total: $100.00 Building Inspector *pG SOlo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 -* roger.richert cl,7i.town.southold.ny.us Southold,NY 11971-0959 mac` oly100um BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Deborah Penney Address: 160 Sailors Needle Lane City: Mattituck St: NY Zip: 11972 Building Permit#: 36776 Section: 144 Block: 5 Lot: . 26 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: Sunation Solar Systems License No: 33412-me SITE DETAILS Office Use Only Residential X Indoor X Basement X Service Only Commerical Outdoor X 1st Floor Pool New Renovation 2nd Floor Hot Tub. Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture ` Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect F1 Switches F1 Twist Lock Exit Fixtures 11 TVSS Other Equipment: PHOTOVOLTAIC SYSTEM, 7848 watts, 42 SunPower 230 modules, 1-SunPower 3301f watt inverter, 1-SunPower 6501f watt inverter Notes: Inspector Signature: Date: Aug 29 2012 81-Cert Electrical Compliance Form.xls OF SOOTy�� - --- TOWN. OF OF SOUTHOLD.BUILDING DEPT. 765-1802 = ' INSPECTION .'. .. , [ ] FOUNDATION 1ST [ ] ROUGH-PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT-PENETRATION [ ] ELECTRICAL (ROUGH) ELECTRICAL (FINAL) REMARKS: DATE f INSPECTORS - FIELD IrISPECOMT M PORT DATE COMMENTS FOUNDATION(1ST) -� - ------------------------------- FOUNDATION(ZND) • z rA ROUGH FRAMWQ& ,y PLUMBING -- ' G INSULATION PRA N.Y. -H STATE ENERGY COME Al FINAL .ADDITIONAL COMMENTS ' O ' (A. �.z TOWN OF SOUTHOLD �' BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD,NY 11971 4 sets of Building Plans TEL:(631)765-1802 Planning Board approval FAX:(631)765-9502 Survey. SoutholdTown.NorthFork.net PERMIT NO. 3 7e� /(/S Check Septic Form N.Y.S.D.E.C. Trustees Flood Permit Examined 7i7 20 Storm-Water Assessment Form Contact. Approved f �/ 20_ Mail to: Disapproved a/c Phone: Expiration 20 Building Inspector APPLICATION FOR BUILDING PERMIT Date /'y 20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant.Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize,in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of Southold,Suffolk County,New York,and other applicable Laws,Ordinances or ons or a it ildings,additions,or alterations or for removal or demolition as herein described.The ® a lic a es co PI i 1 icable laws,ordinances,building code,housing code,and regulations,and to admit rs on pre in building for necessary inspections. APR 2012 J��z (Signature�jo�J plicaLnt or name,if a corporation)a BLDG.DEPT. (Mailingaddressof applicant)' /' — TOD�IN OF SOUTHOLD e w ether applicant is owner,lessee,agent,architect,engineer,general contractor,electrician,plumber or builder 6/.?71rA-CA i- Name of owner of premises Y e b o r,C loen n t V (As on the tax toll or latest deed) If applicant is a corporation,signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. 3 i2—AU-- Other Trade's License No. 14•X; 74 yylo"f-I 1. Location of land on which ropospd work will be d ne: House Number Street Hamlet County Tax Map No. 1000 Section / 7 Block S Lot Subdivision Filed Map No. Lot 2. State existing use and occupancy of premises aAd Mte,n ed se d occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancye 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work 4. Estimated Cost ©O D Fee (Description) (To be paid on filing this application) 5. If dwelling,number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business,commercial or mixed occupancy,specify nature and extent of each type of use. A�q 7. Dimensions of existing structures,if any:Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction:Front Rear Depth Height Number of Stories 9. Size of lot:Front Rear Depth 10.Date of Purchase Name of Former Owner 11.Zone or use district in which premises are situated 12.Does proposed construction violate any zoning law,ordinance or regulation?YES NO 13.Will lot be re-graded?YES NO Will excess fill be removed from premises?YES NO 14.Names of Owner of p emi es eio,,44 ,r"� ���''✓`'N�t4l� La�1A ff � Address Duck- Phone No. Name of Architect L(./ 7 a.4 —' /i Address , ' 3� k one No 786 Yid/ Name of Contractor !/dl//� '�� t ' y Address rokelo. 15 a.Is this property within 100 feet of a tidal wetland or a freshwater wetland?*YES 1// NO * IF YES,SOUTHOLD TOWN TRUSTEES&D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland?*YES NO *IF YES,D.E.C.PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundatio p and dista ces to property lines. �� 17.If elevation at any point on property is at 10 feet or below,must provide topographical data on survey. 18.Are there any covenants and restrictions with respect to this property?*YES NO *IF YES,PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OFF_) n Jrf U �N being duly swom,deposes and says that(s)he is the applicant (Name of individu signing contract)above named, Os the a (Contractor,Agent,Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this S Vof ., otary Public NA F'UBUC,State of NewY40 CAFRUMSigna of Applicant No.01CAS012228 Qualified in Suffolk County�oYs Qom►rds9ion E�irao April 13,..,E Fisher Engineering Services, P.C. PO Box 30 . Oakdale •New York 11769 Phone: (631) 563-9028 December 5, 2012 D E Building Department 14 Subject: Engineer Statement for Solar Roof Installation BLDG.DEPT. Penney Residence: 160 Sailors Needle Lane TOWN OF SOUTHOLD Mattituck, New York 11972 Permit: I have verified the adequacy and structural integrity of the existing roof rafters for mounting the solar collector panels and their installation satisfies the structural roof framing design load requirements of the Residential Code of New York State. I have reviewed and certify that the manufacturer's guidelines and equipment for the photovoltaic equipment for the above residence meet the requirements for wind and snow load and that the roof structure is adequate to carry the new loads imposed by the System. For the installation of the solar mounting,the rails are securely anchored to the rafters utilizing lag screws that have been designed for wind speed criteria of 120 mph Exposure C and snow ground criteria of 20 psf. Wind loads will exceed seismic loads. Other climate and geo design criteria are not applicable to this solar installation. The solar collector system and the mounting assemblies comply with the applicable sections of the Residential Code of New York State- "Solar Systems" and loading requirements of roof-mounted collectors. This system has been installed properly at the above referenced residence. The installation is in accordance with the minimum requirements certified by this letter. I hope that this letter serves and meets with the approval of the Building Department. F NEW OMG. y0. Asti � Sincerely, ` AU W William G. Fisher, ��� 074659 Licensed Professional Engineer Architectural Design•Residential•Light Commercial Additions•Extensions•Conversions Construction Estimates/Oversight•Expediting•Inspections SO!/Tyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 1 1 97 1-0959 �l �� BUILDING DEPARTMENT TOWN OF SOUTHOLD November 27, 2012 SUNation Solar Systems Inc 1217 Montauk Highway Oakdale, NY 11769 RE: Deborah Penney, 160 Sailors Needle Lane, Mattituck, New York TO Whom It May Concern: Please remit another check to replace the enclosed check which is stale dated. The Building Permit for her solar panels was not issued because we didn't receive the amended Trustee permit for the solar panels. The applicant or owner should have submitted this to our office. Since the project has now been completed, I obtained a copy of the permit and our office can now issue the Building Permit when the fee has been submitted. Respectfully, Southold Town Building Dept. C,Z-n Awn C Connie Bunch James F.King,President '*0 so Town Hall Annex Bob Ghosio,Jr.,Vice-President py� 54375 Main Road ti P.O.Box 1179 Dave Bergen Southold,New York 11971-0959 John Bredemeyer G Telephone(631)765-1892 Michael J. Domino 'D i0 Fax(631) 765-6641 ��COUNTI,� BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD June 20, 2012 Ms. Deborah Penney P.O. Box 470 Mattituck, NY 11952 RE: WETLAND PERMIT#7643 160 SAILOR'S NEEDLE RD., MATTITUCK SCTM#144-5-27 Dear Ms. Penney: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wed., June 20, 2012: RESOLVED, that the Southold Town Board of Trustees APPROVES the Amendment to Wetland Permit#7643 to include the installation of a generator and three (3) air, conditioner units along the sides of the dwelling; solar panels onto the roof of the dwelling; patio with walkways; and driveway, as depicted on the plans stamped approved on June 20, 2012, and BE IT FURTHER RESOLVED, that the Southold Town Board of Trustees DENIES the Amendment to Wetland Permit#7643 to install a 5' non turf buffer instead of the required 20' non-turf buffer. This is not a determination from any other agency. Sincerely, e—� v� ' Jame)King,King, Preside 7 Board of Trustees JFK:Ims James F.King,President �oF SOUry Town Hall Annex �0� Ol0 54375 Main Road Bob Ghosio,Jr.,Vice-President P.O.Box 1179 Dave Bergen Southold,New York 11971-0959 John Bredemeyei G • Q Telephone(631) 765-1892 Michael J.Domino Fax(631) 765-6641 BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD December 12, 2012 —_ Ms. Deborah Penney DEC 2 1 2012 LJI PO Box 470 Mattituck, NY 11952 BLDG. DEPT. TOWN OF SOUiHOLD RE: DEBORAH PENNEY 160 SAILORS.NEEDLE ROAD, MATTITUCK SCTM# 144-5-26 Dear Ms. Penney: The following action was taken by the Southold Town Board of Trustees at their Regular Meeting held on Wednesday, December 12, 2012: RESOLVED, that the Southold Town Board of Trustees APPROVE the Administrative Amendment to Wetland Permit#7643 to reduce the size of the non-turf buffer area from 20' to a 17' buffer; 5' of which is existing decking over sand and 12' to be untreated mulch; and as depicted on the revised project plan prepared by Deborah Penney, received on November 13, 2012 and stamped approved on December 12, 2012. Any other activity within 100' of the wetland boundary requires a permit from this office. This is not.a determination from any other agency. If you have any questions, please call our office at (631) 765-1892. Sincerely, v� James F. King President, Board of Trustees JFK:amn James F.King,President �OF So yO Town Hall Annex Bob Ghosio,Jr.,Vice-President 54375 Main Road P.O.Box 1179 Dave Bergen6JIFSouthold, New York 11971-0959 John Bredemeyer G O OQ Telephone(631) 765-1892 Michael J. Domino' Fax(631) 765-6641 COUAMI BOARD OF TOWN TRUSTEES TOWN OF SOUTHOLD CERTIFICATE OF COMPLIANCE #0834C Date: January 8, 2013 THIS CERTIFIES that the removal of the 1,817 sf. dwelling attached garage enclosed porch, wood platform driveway, brick walk septic system; construction of new two story dwelling with 1.5 story attached garage and roofed-over porches; new on-grade patio driveways walkways, septic system leaching pools; installation of generator, three air conditioner units solar panels on dwelling roof, 17' non-turf buffer along landward edge of bulkhead; 5'of which is existing decking over sand and 12' of untreated mulch At 160 Sailors Needle Road, Mattituck New York Suffolk County Tax Map# 144-5-26 Conforms to the application for a Trustees Permit heretofore filed in this office Dated August 24, 2011 pursuant to which Trustees Wetland Permit#7643 Dated September 21, 2011,was.issued and Amended on June 20, 2012, and again on December 12, 2012 and conforms to all of the requirements and conditions of the applicable provisions of law. The project for which this certificate is being issued is for the removal of the 1,817 sf, dwellim, attached garage enclosed porch wood platform driveway brick walk, septic system; construction of new two-story dwelling with 1.5 story attached garage and roofed over porches-new on-grade patio driveway walkways septic system leaching_pools; installation of. generator,three air conditioner units solar panels on dwelling roof 17' non turf buffer along landward edge of bulkhead; 5'of which is existing decking over sand and 12' of untreated mulch The certificate is issued to DEBORAH PENNEY owner of the aforesaid property. c� Authorized Signature i SQ(/ryO! O Town Hall Annex Telephone(631)765-1802 54375 Main Road �r g U2 P.O.sox 1I79 Q roger.richertCa7�tOwr%soutllol{1.nv.us Southold,NY 1197I-0959 �' BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: �—iNw, Date: I� Company Name: Name: C License No.: 33 Address: 1z►-7 ot3 �- (� Phone No.: b31- _7 S 0-6i 4 I: JOBSITE INFORMATION: (*Indicates required information) *Name: New- i rah *Address: ohs cC� *Cross Street: SqQ _- ZI QV `Phone No.: g_ a Permit No.: io Tax-Map District: 1000 Section: Block: c _ Lot: *BRIEF DESCRIPTION OF WORK(Please Print Clearly) S (Please Circle All That Apply) Is job ready for inspection: YE / NO. Rough In Final *Do-you need a Temp Certificate: YES/ NO Temp Information(if needed) *Service Size: 1 Phase 3Phase 100 150 200 300 350 . 400 Other *New Service: Re-connect- Underground Number of Meters Change of Service (!Vter ead Additional In€ormation: PAYMENT DUE WITH APPLICATION la 82-Request for Inspection Form �L J ° G() D15T: 5ECTION: l44 1 BLOCK: 5 1 TAX LOT: 26 SURVEY NO. 10-10159 NOS:-WA(4rtFeYsY5TEA( bWFORAJaMO 9-5-F6C f(o f60ldvE2_ TITLE NO. THE OFFSETS OR DIMEN510N SHOWN HEREON. FROM THE PROPERTY UNE5 TO THE STRUCTURES. ARE FOR A SPECIFIC PURPOSE AND USE, THEREFORE THEY .ARE NOT INTENDED TO MONUMENT THE PROPERTY LINES OR TO GUIDE THE ERECTION OF FENCES. ADDITIONAL STRUCTURES OR ANY OTHER IMPROVEMENT 0 0 AI ',5 N EED L � S LOIN EL=9.G9 + N 79005'00" E +EL=9.49 CL 16o I I O�CG4=99 65 T ff� p' 2 E� BCCEL=9.35 35.00 DCEL=9.40 I L—,4✓ 6 d N VLA � I a N O CA OVERFLOW ca 0 � 3 cV 2 5-p I' %9 �o°�lc,E55FOo \ F LQ GJ 1TT f� 5� u LD/�1o. 8 OVERFLOW, � Ln 10-10 / 1 CE55P00 \ 1 9'-311 � � L�Ao. /O 1 u O ` , �Zp 26I-I I 5'-43' r�^ WAI N LQ p �/0 Z`9 o O F9 SR1 Z O 2� w °9 l— — G1-4111 1 o = 7 ENCLOSED WOOD PORCH PLAT - 20-23 O 2 2s I -----A-REA—� 579 01.� 00 _ -12902.544 Sq. Feet I � I 0.2962 Acre5 WOOD BULKHEAD ' 0 5 800531/ 0" W 95.04 glcig lug 0 ti 1 MAP OF PROPERTY ISLAND WIDE LAND SURVEYORS SITUATE AT PROFESSIONAL LAND 4 CITY 5URVEYOR5 ' MA T T I TUCK 199 E: I-bG -8 DRIVE, 0 PAX:f,N.Y. 11 - I PHONE: I-bGG-808-5800 FAX:5 I G-49G-1792 TOWN OF SOUTHOLD I r /-� /' -�� RECORDS OF WALTER I.BROWN,GUSTAVE A.ROUWER SUFFOLK IiOVNI I, N. Y RT A.HAYNES UNAUTHORIZED ALTERATION OR ADDITION ®� NCI+ TO THI5 SURVEY 15 A VIOLATION OF SECTION 72090E THE NEWYORK STATE SURVEYED : .SEPTEMBER 20, 2010 EDUCATION LAW. ! COPIES OF THI5 SURVEY MAP NOT BEARING THE LAND SURVEYOR'S INKED SEAL OR GUARANTEED TO EMBOSSED 5EAL5HALL NOTBE CONSIDERED TO BE A VALID TRUE COPY. GUARANTEES OR CERTIFICATIONS INDICATED n HEREON SHALL RUN ONLY TO THE PERSON y !iNt'�'i� N w FOR WHOM THE SURVEY 15 PREPARED.AND ON HIS BEHALF TO THE TITLE COMPANY. GOVERNMENTAL AGENCY AND LENDING , INSTITUTION LISTED HEREON,AND TO THE LOT NUMBERS: GUARANTEES OR CERTIFICATIONS TIONSING TIARE NOT LOT No. 9 O�ti �/0 50�25 �4i� TRANSFERABLE TO ADDITIONAL INSTITUTIONS OR SUBSEQUENT OWNERS. "MAP OF SALT LAKE VILLAGE" SFO LAND 5JP DRAFTED BY B.G.SEPT.23,2010 » 15'-6" 9,GG0 W SYSTEM SIZE 14 MODEL 5PR-230 SUNPOWER 230 WATT EA., RAFTIER5 -1)3#/MODULE, G 1 .391 x 3 1 .42"W x 1 .81 "D (2.5#/5F) 70 20'-0" 211x 1 O" @ I G" O.C. (TYP) 71:) HOUSE: G) SOLAR MODULE ARRAY- - � ROOF 42 MODULES TOTAL (� 26'-10" AREAS W Ln RIDGE Z 6� rn - Q - w LU U-j UNIRAC-5UNF I I I LU O 50LARMOUNT PHOTOVOLTAIC I I Q LU }- SYSTEM (TYPICAL_ MODULE (TYF) - I - Z RAIL ACROSS EACH I I � n LU ROW OF ENTIRE I I I I ( �, `17- W a/ Z XARRAY) (Only Two '� I I - �� XXXX U O Shown for Clarity) � XXXXX X - o XX_ - - XX rn I rn 14 MODULE ARRAY: 28 MODULE ARRAY: LU z O �- (2 STRINGS CIF 7 MODULES) (4 STRINGS OF 7 MODULES) 0 - Q 20'-0" Exterior PVC Conduit 12'-10" �, I I FAKTIAL HOU5E ROOF FLAN SOLAR SOLAR DISCONNECT D15CONNEC SCALE: 1 /4" = 1 '-0" ROOF PITCH 5 : 1 2 5FAN : 14'-3" max. I INVERTER ( 1 ) SPR INVERTER ( 1 ) SPR XXXX 3300E G501 XXXX >< INV INV LEGEND U El I Inverter Location Groundin Groundin © M5F Main Service Panel g I g ^/ [9 5P Sub-panel Electrode Electrode 1Y. Ln 0 UM Utility Meter ( � W Ln f=U LL H O U 5 E R00 f- PLAN AC DISCONNECT AC DISCONNECT I�LJ rJCO ® ACD A/C D15connect L/ - I I W � o SCALE: NTS ® B Basement Location �> L MOUNTING BRACKET5 AND HARDWARE MEET OR '�- - - - - Z 0 W I 0 �n J EXCEED NY5 CODE REQUIREMENTS FOR THE D C� En FASTENER REQUIREMENTS: NOTES DE51GN CRITERIA FOR THE TOWN . ° `, $`.te , '' �,�.••.. r; 0 TOTAL ARRAY AREA = 5G3 5F 1 . An 18 wide clearing (free of 5olar equipment) THE ACTUAL IN-FIELD ATTACHMENT TO THE ROOF EXIST. POWER PANELDAFELAaIIILF UJ o WIND LOAD.: A5CE 7 (SEE CALCULATION5 THI5 SHEET) 4 1 .5 F5F , shall be provided along at least oine side of the WILL MEET OR EXCEED NYS RESIDENTIAL CODE PP FF - 5b'--- - -` ` - " - W LU > TOTAL UFLIffT = 41 .5 P5F x 5G3 SF = 23,3G5 LB5 roof ridge on the same side as the solar 2010 RCNY5 REQUIREMENTS. � ; ,�^�� J Z z equipment or on another side of the rid e that 18„ G.Lc .rvlNc INSP� (� o Q FASTENER: 9 ; ,,. �. _��.I��:�-,o°� 0 O z m o does not have solar equipment on it. In addition, `' ! ' r ' ", - W 10a POUREL C.r,.. _ > O 50LARMOUNT LAG SCREW SPEC 203 . 2, 8/04: (FLAT WA5HER5 REQ TO BE an 1 8" wide pathway free of solar equipment) a STRAP STRAPFRAMINPING, �/ � o USED WITH LAG BOLTS p y ( STRAP+NG. ELECTRIc��,_ Q.c�uL Ird� O Lshall be provided from at least one eave or gutter ;. FINAL-C®NSTRUCTION �ELECTRIC' LAG BOLT WITHDRAWAL VALUE; 5/ 1 G" DIA. , 2GG LB/IN X 2-IN THREAD DEPTH= connectin to that 18" roof rid e clearin PHOTOVOLTAIC MODULE EXIST. METER M -__ _ 532 LB. CAP. EACH 9 9 9 idge MUST BE COMPLETE SHALL CO. - ALL CONSTRUCTION SHALL A9EET TI-'G_ O (� REQUIREMENTS OF THE COD`_-S O rJi�UV 2. Roof shall have no more than a single layer of Rail lL MIN. NUMBER Of LAG BO LT5 REQ. = 23,3G5 LB5 / 532 LB5/LAG BOLT = 44 YORK STATE. NOT RESPONSIBLE FOR o = TOTAL RAIL FEET, I G3 FT = I G3 RAIL FT / 44 BOLTS = roof covering in addition to the solar equipment. DESIGN OR CONSTRUCTION ERRORS. LL n MAXIMUM 5FAN BETWEEN MOUNTING FEET BOLT5 "X": 3'-8" MAX 3. Installation of solar equipment shalll be Rafter flush-mounted, parallel to and no imore than SY5TE M ONE LINE D I AG RAM (TYF) G-inches above the surface of the: roof. Roof Span THE PV SYSTEM HAS BEEN DESIGNED TO MEET THE MINIMUM DE51GN STANDARDS FOR 5CALE: NTS 4. Weight of the Installed system shall not exceed �`"• BUILDING AND OTHER STRUCTURES OF THE A5CE 7-05 RCNY5 2010. more than 5-p5f for photovoltaic5 and no more ROOF SECTION (Typ) V\NMG F,s Wind Load Calculation: than G-p5f for residential solar hot water systems. SCALE: NTS BUILDING REVIEW NOTE A5CE 7-05 Partially Enclosed Building De51cjn (Assume Worst Case) TOWN BUILDING PLANS EXAMINER HAS REVIEWED THE ENCLOSED n ''.` 1 UNIRAC RAIL IS DESIGNED AND WARRANTED BY THE h=30ft ( .) DOCUMENT FOR MINIMUM ACCEPTABLE PLAN SUBMITTAL REQUIREMENTS • ; ,���� z Low Rise Building; h< =GOft: Mean Height ; RAILTYP MOUNTING FOOT W/ MANUFACTURER FOR LOADS UP TO 50 LBS/SQ. FT. OF THE TOWN AS SPECIFIED IN THE BUILDING AND/OR RESIDENTIAL C,00`1! r"p '; ;�±s (P _� BUTYL RUBBER MEMBRANE MOUNTING FEET POSITIONED (APPROX. 125 MPH WIND) WHEN INSTALLED AS "` `�\ t� OF THE STATE OF NEW YORK. THIS REVIEW DOES NOT GUARANTEE � 4 , ,, ���'9����`C'�"a,"„ � 9 1 . Directionality Factor: Kd per Section G.5.4.4, (Table G-G): Kd=0.85 BETWEEN FOOT OVER ROOF RAFTER MEMBERS REQUIRED BY THE MAUNUFACTURER. COMPLIANCE WITH THAT CODE. THAT RESPONSIBILITY IS GUARANTE�C) , ;; , � VV f �� o��G�� 0P" PER MFG'S REQUIREMENTS UNDER THE SEAL A.ND SIGNATURE OF THE STATE OF NEW YORK LICEN51D �.•, j`;.,?. °y:'� 2. importance Factor: per Section G.5.5, (Table G- 1 ) Catagory II; I = 1 .0 ROOF SHINGLE OR NO CALK y .DESIGN PROFESSIONAL OF RECORD. THAT SEAL AND SIGNATURE HAS SEEN ' 3. VelocityPressure Coefficient: Kh per Section G.5 .G.4 FLASHING 3 STANDOFF INTERPRETED AS AN ATTESTATION THAT, TO THE BEST OF THE LICENSEES. p HOTOVOLTAIC MODULE NOTE: THE MOUNTING FEET MUST BE ATTACHED TO MOUNTING FEET PER RESIDENTIAL BELIEF AND INFORMATION THE WORK IN THE DOCUMENT IS: (Exposulre Catagory C per G.5 .G (Table G-3); Kh=0.98 THE BUILDING RAFTERS OR FRAMING (NOT JUST THE 'ACCURATE 4. To o ra hic Factor: Kzt per 5ection G.5 .7 (Lon Island); Kzt= I CODE OF NEW YORK STATE ROOF ROOF DECKING). USE 5/ 1 G" OR 3/8" DIAMETER LAG "CONFORMS WITH GOVERNING CODES APPLICABLE AT THE TIME OF THE Date: 4-4- 1 2 p 9 p p g PENETRATIONS CHAPTER 9 (TYP) U NIRAC RAIL SUBMISSION 5 . Gust Factor: G per G.5 .8. 1 , G=0.85 BOLTS AND DRILL PILOT HOLE. FINAL TIGHTENING 'CONFORMS WITH REASONABLE STANDARDS OF PRACTICE AND WITH VIEW TALL FEET X SHALL BE BY HAND. ALL INSTALLATION PROCEDURES TO THE SAFEGUARDING OF LIFE, HEALTH, PROPERTY AND PUBLIC WELFARE Scale: AS SHOWN G. Exposure Classification: per Section G.5 .9 = 11 . .1198" ,:,mnorr, - p SHALL BE PER MANUFACTURERS REQUIREMENTS. IS THE RESPONSIBILITY OF THE LICENSEE 7. Internal Pressure Coefficient: GCpi per 5ection G.5 . 1 I . 1 , Table G-5; GCpi=0.55 @ "x" (MAX FOOT SPAN) 1 8. External) Pressure Coefficient: GCpf per 5ection G. 1 1 . 2. 1 , Figure G- 1 0; STRUCTURAL STATEMENT # I l 074 MAX, SPAN BETWEEN GCpf=0.80 MOUNTING FEET = '48' NOTE: THE EXISTING STRUCTURE IS ADEQUATE TO SUPPORT THE NEW LOADS 9. VelocityFre55ure: qh per 5ection G.5 . 1 0: I Modules and panels and any mounting hardware provided IMPOSED BY THE PHOTOVOLTAIC MODULE SYSTEM INCLUDING UPLIFT t Sheet No. � 1 Shall withstand, without evidence of structural or SHEAR. THE EXISTING RAFTER SIZES t DIMENSIONS CONFORM TO RCNY5 qh=(o.Ioo25G)(Kh)(Kzt)(Kd)(V ^ 2)(1) PHOTOVOLTAIC MODULE SECTION mechanical failure, 1 .5 times the design load when tested TABLE R802.5. 1(1) - RAFTER SPANS qh=(O.10025G)(0.98)( I )(0.85)( I 20 " 2)( 1 ) SCALE: NTS as specified below. The design load is to be 30 psf h-30 .7 TOTAL ROOF DEAD LOAD 10#/SF NOTE: downward(positive) or upward (negative). All glazing oil' I q (ROOF) + 2.5#/5F (MODULE) FASTENERS SHALL NEVER EXCEED 48" BETWEEN RAIL members shall be of such strength to withstand these CLIMATIC � GEOGRAPHIC DE51GN CRITERIA - TABLE R301 . 2( I ) �� r 0. Design Wind Load per 5ection G.S . 12 = 12.5#/5F TOTAL FEET PER MANUFACTURER loads. The modules, panels and any mounting hardware h(GC f GC I) shall be factor erio o GROUND SEISMIC SUBJECT TO DAMAGE BY WINTER ICE SHIELD FLOOD p q p p y tested under these loads fora df p SNOW DESIGN DESIGN UNDERLAY- HAZARDS p=30.7(+0.(50+0.55) UNIRAC RAIL INSTALLATION 30 minutes. (Downward * upward forces shall not be LOAD Speed CATEGORY WEATHERING FROST LINE TERMITE TEMP MENT ' applied 51multaneou5l (mph) DEPTH REQUIRED p=30.7( I .35) GUIDELINES PER MANUFACTURES MOUNTING BRACKET MATERIALS ARE pp y MOD. TO 5EE p=41 .5 psf REQUIREMENTS NON-COMBUSTIBLE IN ACORDANCE WITH RM2301 .2.2 20 PSF 120 B SF=VERE 3 0' HEAVY I I deg NA EEXLAA. AND CONSIST OF ALUMINUM L BRACKETS