Loading...
HomeMy WebLinkAbout32396-Z SufFOtk. Town of Southold Annex 6/14/2013 � •,y� P:O.Box 1179 54375 Main Road. oy. Southold_;New York 11971 -CERTIFICATE OF OCCUPANCY No: 36299 Date: 6/14/2013 THIS CERTIFIES that the building SINGLE FAMILY DWELLING Location of ProP'ertY: 635 STROHSON RD CUTCHOGUE;. SCTM#: 473889 Sec/Block/Lot: 103.40-12 Subdivision: Filed Map No. Lot.No: conforms substantially to the Application for Building Permit heretofore filed in this officed dated Pursuant to which Building Permit No. 32396 dated 9/28/2006 was issued,and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is:.. one family dwelling as per ZBA 5624, dated 12/29/04, and"as built"accessory pergola as applied for. The certificate is issued to GRACE M KEBLE (OWNER) of the:aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10=05-0061 4/24/13 ELECTRICAL CERTIFICATE NO;: . 3019354. :.. 4/29/08 PLUMBERS CERTIFICATION DATED 4/29/08 George Fredricks Autho ' Signature FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO. 32396 Z Date SEPTEMBER 28, 2006 Permission is hereby granted to: G KEHLE C/O J CONDON 1755 SIGSBEE RD MATTITUCK,NY 11952 for CONVERSION TO A NEW SINGLE FAMILY DWELLING AS APPLIED FOR PER ZBA DECISION #5624 at premises located at 635 STROHSON RD CUTCHOGUE County Tax Map No. 473889 Section 103 Block 0010 Lot No. 012 pursuant to application dated SEPTEMBER 25, 2006 and approved by the Building Inspector to expire on MARCH 28, 2008 . Fee $ 306 . 00 Authorized Signature ORIGINAL Rev. 5/8/02 Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL ? JUL 2008 !.mJ 765-1802 - B nG. DEPT. .r`. APPLICATION FOR CERTIFICATE OF OCCUPANCY TOWN OF SOUTHOLD This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines, streets, and unusual natural or topographic features. 2. Final Approval from Health Dept. of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1%lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations, a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings (prior to April 9, 1957) non-conforming uses, or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines, streets,building and unusual natural or topographic features.. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certificate of Occupancy-New dwelling$25.00, Additions to dwelling$25.00,Alterations to dwelling$25.00, Swimming pool$25.00,Accessory building$25.00, Additions to accessory building$25.00,Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 5. Temporary Certificate of Occupancy-Residential$15.00, Commercial$15.00 Date. 7 New Construction: Old or Pre-existing Building: 1/ (check one) Location of Property: 6 3,�— S—1 eoN Sd j A 0 t G X o u,-_ House No. Street Hamlet Owner or Owners of Property: k-66 CE Suffolk County Tax Map No 1000, Section Aa3 Block Lot Subdivision Filed Map. Lot: Permit No. 37— Date of Permit. ! ' l S o 6 Applicant: Health Dept. Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: check one) Fee Submitted: $ aZS. 00 2A A licant Signature 4 5 BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5. 5 5 5 BUREAU OF ELECTRICITY S S40 FULTON STREET — NEW YORK, NY 10038 5 CERTIFIES THAT 5 5 5 5 Upon the application of upon premises owned by. c5 5 SPLATINUM EAST ELECTRIC RON KEEL S Dj 1320 KENNEY'S RD � �� 454STROHSON RD 5 5 SOUTHOLD, NY 14971, CUTCHOGUE, NY 11935 C5 S Located L a at 450 STROHSON RD CUTCHOGUE, NY 11935 S S oc CSj Application Number: 3019354 ;Certificate Number: 3019354 5 5 - S 5 Section: Block: Lot: Building Permit: BDC: ns11 5 5 5 5 Described as a occupancy, wherein the premises electrical system consisting of S electrical devices and wiring, described 'below, located in/on the premises at: 5 First Floor,cottage,Outside, 5 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed Dj S herein, was conducted in accordance with the requirements if the applicable code and/or standard 5 promulgated by the State of New York, Department of State Code Enforcement and Administration, or other 5 5 authority having jurisdiction, and found to be in compliance therewith on the 29th Day�of April,2008. 5 5 Name QTY Rate Rating Circuit Tyne 5 5 Alarm and Emergency Equipment 5 5 Sensor 4 1 0 Carbon Monoxide 5 5 Sensor 3 0 Smoke 5 5 Appliances and Accessories 5 5 Dish Washer 1 0 1.2 KW 5 5 Furnace 1 0 Oil SExhaust Fan 2 0 'F.H.P. 5 Air Conditioner 1 0 30.000 BTU 5 Wiring and Devices 5 5 Outlet 36 0 Fixture 5 5 Fixture 32 0 Incandescent Fixture 4 0 Flourescent 5 SOutlet 51 0 General Purpose C, Receptacle 26 0 General Purpose 5 C Switch 31 '0 General Purpose 5 Lj Receptacle l 0 20a Laundry �S 5 Receptacle 1 0 30a Dryer seal Paddle Fan 3 0 5 Continued on Next Page 1 of 2 S 55 - 5 This certificate may not be altered in any and is validated only by the presence of a raised seal at the location.i,ndicated, S 5 o nnnn -�r��@3 En�n�����r3J-������n�n�n�r��n�� . n ������nnrn�n a�n 4' 4 0 r�rJ�rJ�r�-rJ�r�rJ�rJ��t-r�cnr�r�r��nrJ�r�r.J�cPrJr�cJ�rJ�cnr�rJ-r n�nr�rJ�r�cnrJ��nr.PrJrJr�cPrJ�rJ�rJc.fr RIMPLrrr3�.rc rft' P1 J�rJ�rJ�r�rJ�r��ncPrJ�r�rJ� 0 5 'BY THIS CERTIFICATE OF COMPLIANCE THE 5 5 NEW YORK BOARD OF FIRE UNDERWRITERS 5 5 S S BUREAU OF ELECTRICITY 5 5 40 FULTON STREET - NEW YORK, NY 10038 C5 5 CERTIFIES THAT 5 5 5 5 Upon the application of upon premises owned by 5 5 5 PLATINUM EAST ELECTRIC RON KEEL 5 5 1320 KENNEY'S RD 450 STROHSON RD 5 5 SOUTHOLD, NY 11971, CUTCHOGUE, NY 11935 5 5 5 Located at 450 STROHSON RD CUTCHOGUE, NY 11935 5 5 5 Application Number: Certificate Number: 5 PP 3019354 3019354 a u cS 5 ns11 Section: Block: Lot: Building Permit: BDC: S 5 5 5 Described as a occupancy, wherein the premises electrical system consisting of 5 electrical devices and wiring, described below, located in/on the premises at: 5 First Floor,cottage;Outside, 5 5 5 5 5 A visual inspection of the premises electrical system, limited to electrical devices and wiring to the extent detailed 5 herein, was conducted in accordance with the requirements of the applicable code and/or standard 5 promulgated 5 by jurisdiction, State of New York, Department of State Code Enforcement and Administration, or other au thority y Navin urisdicton, and found to be in compliance therewith on the 29th Day of Apri1,2008. Name y c 5 OTY Rate EgiLig Circuit Type S 5 Disconnect 1 0 60a Air Conditioner 5 5 Receptacle 8 0 GFCI S 5 Service 5 5 1 Phase 3 W Service Rating 200 Amperes 5 5 Service Disconnect: 1 200 cb 5 Meters: I 5 S 5 5 5 5 5 . S 5 5 5 5 5 5 5 seal 5 2 of 2 5 5 This certificate may not be altered in any way and is validated only by the presence of a raised seal at the location indicated. 5 5 o ������������������MPL���������LPLL3rr3p rL3 rL3 rd3���������������������r ���� o o Town Hall,53095 Main Road p • �� P.O..Box 1179 y 'Fax(631)765-9502 Southold, New York 11971-0959 .( � Telephone(631)765-1802 BUILDING DEPARTMENT r TOWN OF SOUTHOLD APR 2,9 2008 L4 CERTIFICATION ELDG. DEPT. TOWN OF SOUTHOLD Date: �" 0lop Building Permit No. 3 Z 3 9 6 Z Owner: xelle (Please print) Plumber: toed 6yj ri,C,IcS (Please print) I certify that the solder used in the water supply systealessrsthaIrg, 2 f 1% lead. ) Sworn to before.me this W_WIJ day of A .. .. 20 Grr Notary Public, J U ,.County LlADA P.i-.MNUULF h NC•TRRY PUBLIC,State Of N"Y4* No.01 RA8148660, (lu®lM In 8Wk*0W* Comm) W*f W M J*90-L0 �o OF s0 G�o TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1STK' ROUGH PLOG. [ ] FOUNDATION 2ND [ ] INSULATION FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: L a r Vft- 1 DATE °���o INSPECTOR 0f SOUly�`o , TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: P DATE �� f I�� INSPECTOR ..� OF SO(/lyOlo TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST ROUGH PLOD. •� e [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: ' DATE INSPECTOR OP SOUTyo�o 3 �-3 - urm,��' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION . ] FOUNDATION 1ST [ ] ROUGH PLBG. ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING ,[ FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: G" BID La I DATE r�0 INSPECTOR G` pF SO(/jyolo • a� courm,N�' TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING P�f— L 9L [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR 7 cou TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: �/ - i r DATE INSPECTOR D Q A o K ASSOCIATE LLC residential & commercial design e engineering o consulting June 10th, 2013 Southold Town Building Department pn Reference: Engineers Final Inspection R E C V Project Location: Kenny Residence JUN 14 2013 635 Strohson Road Cutchogue, NY 11935 S.C.T.M. # 1000- 103.0- 10.0 -012 BLDG.DEPT. TOWN OF SOUTHOLD To Whom It May Concern: In reference to the Kenny Residence, located at 635 Strohson Road, Cutchogue, NY. 11935. A final inspection has been performed at the above residence on the Pergola attached to the rear of the house. The Pergola constructi in compliance with the NY State code at the time of �i spection. n rely. OF NEWY F5�. DEE,� op Q _ �0 rn James D. De` koski P.E. Fo t ?w oti R�FESS NPR' Deerkoski • Arm • Kehl Associates , LLC PO. Box 1675 , Southold , New York 1 1 9 7 1 Phone: (631)433-9084 Email: ssbn654@optonline.net Fax: (631)466-3354 FIELD INSPECTION REPORT DATE COMMENTS I, 9� FOUNDATION(1ST) C A ------------------------------- FOUNDATION(2ND) z 3 � z Ul y ROUGH FRAMING& —y PLUMBING I A I y INSULATION PER N.Y. STATE ENERGY CODE ' c — Q - - FINAL -18 n D 81..E i mrn i a ADDITIONAL COMMENTS (t� to -1113 o o i �3 - Lor 6� y O z 7�) a 4 � Od O � �y 10WN oir Sou BUILi)IN(iVEkW'I'A-PljLIUA:I'ION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? 25 -2 TOWN HALL Board of Health SOUTHOLD,NY 11971 ) 4 sets of Building Plans 2 5 '200G, TEL: (631) 765-1802 Planning B dapproval FAX: (631)765-9502 Survey www. northforLnet/Southold/­—TERAHT'N'O.-'�--� Checker Septic Form N.Y.S.D.E.C. V-- Trustees Examined— 20 Contact; Approved— 20 0,417 Mail to: Disapproved a/c pc Phone:Q rg'- I Expiration 20 'Building Inspector CAT ION FOR BUILDING PERMIT Date 20 INSTRUCTIONS a.This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 3 sets of plans,accurate plot plan to scale.Fee according to schedule. b.Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas,and waterways. c.The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. I f.Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date.If no zoning amendments or other regulations affecting the property have been enacted in the interim,the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter,a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York,and other applicable Laws, Ordinances or Regulations,for the construction of buildings,additions,or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws,ordinances,building code,housing code,and regulations,and to admit authorized inspectors on premises and in building for necessary inspections. 5 (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, agent, architect, engineer, general contractor, electrician,plumber or builder Name of owner of premises Pont (As on the tax roll or latest deed) If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer). Builders License No. Plumbers License No. Electricians License No. ✓ Other Trade's License No. 1. Location of land on which proposed work will be done: 6 �S 57-e-o)4goAf 4AO C u-rc-14 o6 u C House Number Street Hamlet County Tax Map No. 1000 Section 103 Block p Lot IZ- Subdivision rFiled Map No. Lot (Name) 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy CPJ}'A6 F b. Intended use and occupancy 015S I D TjA-L 2 3 3. Nature of work(check which applicable):New Building Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front LR S S Rear 143, Depth 3/ Height 15 Number of Stories Dimensions of same structure with alterations or additions: Front �/�.S Rear Depth 31 -3 Height 1.S Number of Stories 7 S. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot:Fron 3 o y / Rear 270.9 r Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation?YES NO GeO 13. Will lot be re-graded?YES NO /Will excess fill be removed from premises?YES NO !/ 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO t,-' *IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C.PERMITS MAY BE REQUIRED. b.Is this property within 300 feet of a tidal wetland? *YES NO_kW * IF YES,D.E.C. PERMITS MAY BE REQUIRED. 16.Provide survey,to scale,with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) QP SS: COUNTY OF U , being duly sworn,deposes and says that(s)he is the applicant (Name of individual signing contract)above named, ;� (S)He is the a o r�. 6 J co^J `-� 6 11�j (Contractor,Agent, Corporate Officer,etc.) of said owner or owners,and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this applicationare true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me thi 44 -day of 200 5 Notary Public �`- gnature of Applicant LINDA S.TAGGART Notary Pubiv.. state of New York No 4948506 Qualifies m Suffolk County- Commission Expires March 20,_,_�D� APPEALS BOARD MEMBERS pv OG Southold Town Hall Ruth D.Oliva,Chairwoman a y 53095 Main Road Gerard P. Goehringer y P.O. Box 1179 Lvdia A.Tortora O Southold,NY 11971-0959 Vincent Orlando Tel.(631)765.1809 James Diiniiio,Jr. 1 t �a Fax(631)765-9064 http:I/southoldrown.northfork.net RECEIVED fG BOARD OF APPEALS ?' is Plv TOWN OF SOUTHOLD J A N ' '. 2005 FINDINGS, DELIBERATIONS AND DETERMINA S0sth0li Tawn Jerk MEETING OF DECEMBER 29, 2004 ZB#5624—GRACE KEHLE Property Location: 630 Strohson Road, Cutchogue; CTM 103-10-12. SEQRA DETERMINATION: The Zoning Board of Appeals has visited the property under` consideration in this application and determines that this review falls under the Type 11 category of the State's List of Actions,without an adverse effect on the environment if the project is implemented as planned. PROPERTY FACTS/DESCRIPTION: The applicant's property consists of 27,668 sq. ft. and has two front yards facing Strohson Road, Cutchogue. The property is improved with only a frame garage for which Certificate of Occupancy#Z-6887 was issued. The garage is shown on Parcel A, on the June 12, 2002 survey prepared by John C. Ehlers, L.S. with setbacks at 10 feet and 17.5 feet at its closest points to the southeasterly front lot line at Strohson Road. BASIS OF APPLICATION: Building Department's May 25, 2004 Notice of Disapproval, amended August 4, 2004 citing Section 100-244 in its denial of a building permit to construct a proposed conversion of the existing accessory garage building located at less than 40 feet,from the front property line,for conversion into a single-family dwelling. FINDINGS OF FACT The Zoning Board of Appeals held a public hearing on this application on December 16, 2004 at which time written and oral evidence were presented. Based upon all testimony, documentation, personal inspection of the property, and other evidence,the Zoning Board finds the following facts to be true and relevant: AREA VARIANCE RELIEF REQUESTED: The applicant wishes to obtain a building permit for conversion of the only existing building on this lot from an one-story accessory garage incidental to the owner's adjacent residence on CTM 103-10-20, to a (one-story) single-family dwelling as a principal use. REASONS FOR BOARD ACTION: On the basis of testimony presented, materials submitted and personal inspections, the Board makes the following findings: 1. Grant of the variance will not produce an undesirable change in the character of the neighborhood or a detriment to nearby properties. The renovation of this preexisting, nonconforming i garage will be an upgrade of a deteriorating structure. The renovations and alterations will be one- . Page 2—December 29,2004 File No. 5624—Grace Kehle CTM Id: 103-10-12 story and within the existing 31'6" by 43'6" building, and the preexisting front yard setback of 10 feet at its closest point will remain unchanged. 2. The benefit sought by the applicant cannot be achieved by some method, feasible for the applicant to pursue, other than an area variance. The existing structure is nonconforming in that it does not meet the current code requirement of 40 feet. Since the existing foundation and structure have been found to be structurally sound, moving the structure is not economically feasible. 3. The variance granted herein is substantial with a 75% reduction from the code required 40 feet. 4. The difficulty has been self-created and is related to the applicant's desire to use and convert the existing garage to a single-family dwelling. 5. No evidence has been submitted to suggest that a variance in this residential community will have an adverse impact on the physical or environmental conditions in the neighborhood. 6. Grant of the requested relief is the minimum action necessary and adequate to enable the applicant to enjoy the benefit of a single-family dwelling, while preserving and protecting the character of the neighborhood and the health, safety and welfare of the community. RESOLUTION OF THE BOARD: In considering all of,the above factors and applying the balancing test under New York Town Law 267-13, motion was offered by Member Orlando, seconded by Member Goehringer, and duly carried,to GRANT the variance as applied for, as shown on the June 12, 2002 (final) survey prepared by John C. Ehlers, L.S. and applicant's 9/20/04 elevation sketch, SUBJECT TO THE FOLLOWING CONDITIONS: 1. The area to be converted within the existing garage into living area shall be the minimum to meet codes (presently 850 sq.ft. of living area). 2. The building shall remain as one-story within the existing front yard nonconforming setback area. This action does not authorize or condone any current or future-use, setback or other feature of the subject property that may violate the,Zoning Code, other than such uses, setbacks and other features as are expressly addressed in this action. Vote of the Board:Ayes: Members Orlando (Acting Chairman), Goehringer and Dinizio. Absent Page 3—December 29,2004 File No.5624—Grace Kehle CTM Id: 103-10-12 were Chairwoman Oliva and Member Tortora. T s R o n'w duly opted (3-0). Vincen rla o, cting hairman 1/ 105 Approved for Filing New York State Department of Environmental Conservation Division of Environmental Permits, Region-One Building 40 -SUNY, Stony Brook, New York 11790-2356 Phone: (631)444-0365 • FAX: (631)444-0360 Website: www.dec.state.ny.us Denise M.Sheehan Commissioner LETTER OF NO JURISDICTION -TIDAL WETLANDS ACT Grace M. Kehle September 21, 2006 53 Old Hill Road Westport, CT 06880 Re: Application #1-4738-03589/00001 Kehle Property, 635 Strohson Road, Cutchogue, NY 11935 S.C.T.M. #1000-103-10-12 Dear Ms. Kehle: Based on the information you have submitted, the Department of Environmental Conservation has determined that the property located at,.635:Stohson Ro.ad'in Cutchogue, landward of the 10 foot elevation contour, as shown on the.survey prepared by John C. Ehlers last revised 10-17-00, is beyond Tidal Wetlands Act (Article,25),jurisdiction. Therefore, in accordance with the current Tidal Wetlands Regulations (6NYCRR Part 661),' no permit is required. Be advised, however, that no construction, sedimentation, or disturbance of any kind. may take place seaward of the tidal wetlands jurisdictional,boundary, as indicated above, without a permit. It is your responsibility to ensure that all precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Tidal Wetlands jurisdiction which may result from your project. Such precautions may'include maintaining adequate work area between the tidal wetland jurisdictional boundary and your project (i.e. a 15'to 20' wide construction area) or erecting a temporary fence, barrier, or hale bay berm. Please note that this letter does not relieve you of the responsibility of obtaining any necessary permits or approvals from other agencies or local municipalities. Sincerely, ,Mark Carrara':_::. .:.Deputy Permit.Administrator:= cc: Condon Engineering, P.C. MHP file (kaf) 2 '3 ..��� Condon Engineering, P.C. New York State Licensed Professional Engineers 1755 Sigsbee Road 631-298-1986 Mattituck,New York 11952 Fax 631-298-2651 April 29, 2008 Mr. Michael Verity- Chief Building Inspector Building Department Southold Town Hall 53095 Route 25 P.O. Box 1179 Southold, New York 11971 RE: Kehl Property, 635 Strohson Road, Cutchogue, New York SCTM: 1000-103-10-12 Dear Mr. Gillen: As requested, attached please find two copies of the revised energy calculations for the above referenced project. The use of R-21 insulation in the ceilings meets the current Building Code of New York energy code requirements. Please call me if you have any questions. Yours tr y, J . C on, P.E. cc. Ron Kehle OF SOUr�ol � o Town Hall,53095 Main Road Fax(631)765-9502 P.O.Box 1179 G.�t` • Q Telephone(631)765-1802 Southold,New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD May 29, 2008 brace A Kehle 53 Old Hill Road Westport, Ct. 06880 RE SCTM: #103,40-20 Premises:-058-5trohson Road Dear Ms Kehle, The Building Department has received notice that construction was done at the above premises without first obtaining a building permit. According to the code of the Town of Southold, a building permit is required before any construction can be undertaken. Please contact our office as soon as possible so this matter can be resolved, 631-765-1802 Respectfully, Southold Town Building Dept. SO(/r�ol h O Town Hall,53095 Main Road Fax(631)765-9502 P.O.Box 1179 G • Telephone(631)765-1802 Southold,New York 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD June 26, 2008 G.Kehle C/O J Condon 1755 Sigsbee Rd. Mattituck N.Y. 11952 To Whom It May Concern: We are unable to complete your Certificate of Occupancy because of the following reasons: XAn application for Certificate of Occupancy is not on file. (Enclosed) No Electrical Certificate on file. e Check is not on file-$25.00 No Health Department Approval on file. No final inspection has been made. No Plumber Solder Certificate on file. (All permits involving plumbing being issued after April 1, 1984) Certificate of Compliance from Southold Town Trustees. Approval of the Zoning Board of Appeals* Final Planning Board Approval. BP#32396 Alter Garage to Dwelling oF so�ryolo Town Hall Annex Telephone(631)765-1802 54375 Main Road 4 Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD September 7, 2011 Grace Kehle 53 Old Hill Rd Westport, CT 06880 Re: 635 Strohson Rd., Cutchogue TO WHOM IT MAY CONCERN: The Following Item(s)Are Needed To Complete Your Certificate of Occupancy: Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. /A fee of$25.00. — Check is enclosed which is outdated Final Health Department Approval. Plumbers Solder Certificate. (All permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892) Final Planning Board Approval. Final Fire Inspection from Fire Marshall. Final Landmark Preservation approval. BUILDING PERMIT : 32396 —Alter Garage to Dwelling so�ryo Town Hall Annex ~� l0 Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 P.O.Box 1179 Southold,NY 11971-0959 0 �� �yCOUNT'1,� BUILDING DEPARTMENT TOWN OF SOUTHOLD January 11, 2012 Grace Kehle 53 Old Hill Rd Westport, CT 06880 Re: 635 Strohson Rd., Cutchogue TO WHOM IT MAY CONCERN: The Following Item(s)Are Needed To Complete Your Certificate of Occupancy. Application for Certificate of Occupancy. (Enclosed) Electrical Underwriters Certificate. fee of$25.00. (outdated check was previously returned) Final Health Department Approval. Plumbers Solder Certificate. (All.permits involving plumbing after 4/1/84) Trustees Certificate of Compliance. (Town Trustees#765-1892j Final Planning Board Approval. Final Fire Inspection from Fire Marshall. — Bob Fisher Final Landmark Preservation approval. BUILDING PERMIT: 32396 —Alter Garage to Dwelling 1 / 8'011,200 Gallon Septic Tank 1'min. / 2'Max 4"SDR 35 PVC Waste Line J / Locking Casting Pitch-%Inch per Foot 15 .e S83B '00/"E 152.79' Min.To Grade 1'min. /�Existing Grade / 20" Concrete cover 2'Max /"27 15.6 I 6" / ( Flow Baffle / ) I Invert=-1.33J 6. 1 Invert=-1.63 invert=-2.13 nvert=-2.23 EXISTING 8'0 8' 4" DEEP LEACHING 4"S R 35 PVC Waste Line rj / POOL(TYP.). FILL IN WITH CLEAN Q q Q 1 B" SAND TO REDUCE EFFECTIVE o O Pitctl{-y Inch per Foot 8'min 8'DIA. PROPOSED 8'0 6'DEEP DEPTH OF RINGS TO 6'. p LEACHING POOL To I I ' 8'0 6'DEEP O 4' EXPANSION LEACHING _ ' POOL SOILOIL B �,A." o � PROP.1MIN,200 I O I I 8'DIA. �J GAL SEPTIC' PROPOSED 4'FROM BATHROOM TANK X ' Ground Water Elevation El.-10.9 m 5 S _____ ________ ______ C MIN C� I PROPOSED4' FROM KITCHEN 4- SANITARY PROFILE FILL EXISTING LEACHING POOL WITH EXISTING GARAGE TO BE CONVERTED TO 1 CLEAN SAND TO REDUCE EFFECTIVE STORY RESIDENCE [PROPOSED SCALE:1"=5' DEPTH OF RINGS FROM 8'TO 6'. o WATER SERVICE z EXISTING ) I W_ 1s r} to DIRT f1b� 1-0 DRIVEWAY \ *0 t( l CO i M O v7 r , ROPE � 1a.6 SON off NOTES: S Assumed Grade 13.1t r.•, ''�/ / t ;'Dark Brown Sandy Loam 1. LOT AREA=27,668 S.F.OR 0.64 ACRES. •-3 k,-; { �t t�3 OL1. 2. ALL ADJACENT PROPERTIES WITHIN 150 OF THE SITES ` t �.. Brown Silty Sand ARE SERVICED BY PUBLIC WATER OR DO NOT HAVE \ / Q SM WATER SERVICE. 25' 3. EXISTING TOPOGRAPHIC INFORMATION BASED ON ,� C G THE SCDPW TOPOGRAPHIC MAPS SHEET BB-36 DATED MARCH 12,1974. J c e SITEPLAN F 000zoNe KEL el v Pale Bro SPineSand SITE PLAN PREPARED FROM SURVEY BY: / EDGE of TIDAL wETL*MPM JOHN C.EHLERS LAND SURVEYOR / / "DECg7LMI 10.9'(Water)EL.2.2t Health Department Approval Stamp DATED 6/12/2002 / flF f;FW SCTM:1000-103-10-12 i- �'�� _ O� SCALE:1"=40' c�` !- CO �40 Water in Pale Plans are prepared by Condon Engineering,P.C. It is a violation of the New York State Education Law,Article 145,Section 7209,for any r + Z Brown Fine Sand person unless acting under the direction of a licensed Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an SP item bearing the seal of an Engineer,Architect,or Land Surveyor is altered,the aftering Engineer,Architect,or Land Surveyor shall affix to the Rem his/her seal and the notation'Atered by'followed by his/her signature and the date of such alterations,and a specific description Cy i of the alteration. 17' KEHLE RESIDENCE JF C51684 .� ; SCALE:AS SHOWN Condon En ineerin , P.C. 635STROHSONROAD G k, Soil boring data by g• g McDonald Geoscience, CUTCHOGUE,NEW YORK wn Apri11,20D5 Dram by,uC 1755 Sigsbee Road Matt'Ituck,New York 11952 PM1 Date, AJ25M (631)298-1966 SANITARY PLAN 110/12105SCDHSCOW 11117f05 SCDHS COMrt 5URVEY OF PROPERTY 51TUATE: GUTGHOGUE N TOWN: 5OUTHOLD 5UEEOLK COUNTY, NY W E SURVEYED 05-22-00 FINAL SURVEY 10-06-2008 RE DATE 04-0I-2013 S SUFFOLK GOUNTY TAX # 1000-105-10-12 , ui h SUFFOLK GOUNTY.DEPT. HEALTH 5ERVIGE5 REF. # RIO - 05 - 0061UJ i CIE) TfRED TO: + ssF t i GRACEM.H EHLLE COMMONWEALTH MONWEA1LTH LAND TIlTL]E HNSURANCIE COMPANYU. u. a � LAND NOW PR FORMERLY OF JAME5 MATHER&EILEEN SULLIVAN FORMERLY OF MILDRED W.DORAN X S8802TWI E 152.791 FF- X_—X__ L 0.1 K x X--X X--X—X—X-- X—X—X—x- 24� YUF2E F$1GE t£ 2DS X I X t I 1 1 X � N ti x t I . r t 700 X r1 — c 7, >a_ I &C" v' Yl� m - t S , -'0"' a+ � N`n t?• .70 � I ��` STORY t' water water' j 70 N X W FRAME "OUS1= Mine meter O I + toe• : l T • X 1 � \ S R%CES 0-N�Al.T3� �R x •,� L1g:o;>ti11\'4'ORKSFO ® Apf ,.•rc+ 'ti.41~I:',a.miLYR o 0 5 •v®6� I X � .1ti.�'i.tv�. APR 2 t-1..� n tooI � trsis'tUc�tion have X /'`� ® avatar supGlY facl!it1es of and tours to _e disposal and ar`��;ent or aLher al3encizs' d►or carufled DY this Dep fiEDROQtv.S. Xggx/x 73.1 ,�. t:�s �` FOR ACItJIl1M �, t • pt, lileT ~'� Walter J.Hilbert. ement Office o�Wastewater Manag NC �� Cj.��bY ® v+wlooreea meerotlon«otlmtw,e o�.,,ey mpblptbn a sects l209,stbtleNi«slon 2-1 tM ��O� NY[)�� Nen Y«k Stole EArcoHon Lco+: 'Only copies trap t.•«iy'rini of tnb sa..ey ketl S I «lyknl lie corekfa t Irntl wrveyorb 5tmpetl seesl 51.011 red to be valitl lrve / copies' fi •eenrtmmwo xlm�mea e�reon symy tint ws p rep o NOTE5: Osn of Pal ««co ernsco aeno d owd � s reobk rvy1 ' 5o1e t11 s 1 ——ty ■ MONUMENT FOUND �qs 502 �QJ� a y r c. Z LAND w e ah yn s er t n ie�nq unumua.ce tlnw- LWn«e rot traasreroble to otltlltkmal�lit.11a� Area = 27,675 50 FT JOIN C. EHLERS LAND SURVEYOR Area = 0.64 AGRE5 GRAPHIC 5G,4LE 6 EAST MAIN STREET N.Y.S.LIC.NO.50202 RIVERHEAD,N.Y. 11901 369-8288 Fax 369-8287 REF.C:\Users\Tohn\Dropbox\2000 PROS\2000 pros\20-244GAR FINAL-Pro 5UR VEY OF PROPERTY 51TUATE: GUTGHOGUE TOWN: 5OUTHOLD 5UEEOLK GOUNTY, NY V11 Ile, E SURVEYED 08-22-00 FINAL SURVEY 10-06-200& RE DATE 04-01-2013 S t- SUFFOLK COUNTY TAX # 1000-103-10-12 r SUFFOLK COUNTY DEPT. HEALTH SERVICES REF. # RIO - 05 - 0061 Uj �TMED TO: cc e GRACE M.ICE � s` COMMONWEALTH LAND nTLE INSURANCE COMPANY u"�' Ll :ZZ LAND NOW PR FORMERLY OF JAMES MATHER&EILEEN SULLIVAN FORMERLY OF MILDRED W.DORAN X S88027'00"E 152.791 x_X_ c . t� x�—X----x —_X— O.1'N X x x-x-- 42E YORE F9iGE x FE 2OS x I x t I ' ; 1 x ' 1 I w , X N; r 70 r- LQ x D s ; --A 00 I c� y Zla \ d' MZ c $. 32.0' - Q M j I o m X , < —n 45-W ' 713 foC i RY ' water water! 70 N x W FRP.ME HOUSE line "tef 0 O ( ```..ram, + toe' Cl) x tit RO�yyp.Y �\\ �I }i�ALTH ' O� it °DEPh- a� x „pc UcFOLY,c •. t -r WORKS FOR RUC APPR;%'rr"` ;: yhhlLl'RE.S1E14Ct: -006 APR"2 1 H.S.Rr-,i.PVo. n faclh5eS at lr'isylncation have ter sup>;IY , encles and tours to s disposal and wa afnen►ar EED OQiv;S. x� �'t1e`'eN timed by this DeP " K 131� _ Ins andIFORAM WMt1M F•� saustacm ' t..- -� Walter J.Hubert.P• ement " tftce®t Wastewater Mana NE •tMAhorized 11t 1ti o,oclaittan to o sw..ey l,t o Iic Vl b siwv pros s2, is n lalation or section Y-1 .t.E bn�.a1 the rw Nen Yak Stale Edlcation Lm+.' copies F—t —9a 1 or W,svvey ma'ked -p-iy"mol of tM I surveyors 1 I 'k slrmpea sent shop be cws -d to W—11d true NOTES: 4 -G mricot m s I vyka etl he eon s4y6y that Nis Qey r.�prepQetl b occoreuee nnn the e.- �/ �t. /� ` O bytu ,Yoo'rk state Ass�oa�a ■ MONUMENT FOUND ��'V 602 �,v� mtl b otf to Dw t111,cotlo s hall n o ly V ,` to f person For--rho—.y Is prep—d. v tnl o]ercay otd lend j b�stiWlionpeG herein.and �D LAND 5 to ire nsslgees of u�a IeM'ug w,uwtwa eerllrlco- twr�ore riot lro�rermle to atlditbnol nstnotlnr� Area = 8 SQ FT 0.64 Area = 0.64 ACRES JO1� 1L C. E E S SURVEYOR . � GRAPHIC, 5GALE I"-30' 6 EAST MAIN STREET N.Y.S.LIC.NO.50202 RIVERHEAD,N.Y. 11901 369-8288 Fax 369-8287 REF.C:\UsersVohn\DropboA2000 PROS\2000 pros\20-244GAR FINAL.pro ,JREScheck Software Version 4.1.3 ,41"' Compliance Certificate Project Title: KEHLE RESIDENCE (Revised) Report Date:04/29/08 Data filename:CAProgram Files\Check\REScheck\KEHLE.rck Energy Code: 2007 New York Energy Conservation Construction Code Location: Suffolk County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 13% Heating Degree Days: 5750 Construction Site: Owner/Agent: Designer/Contractor: Permit Date:2/2/2005 John Condon Condon Engineering,P.C. 1755 Sigsbee Road Mattituck,NY 11952 631-298-1986 Qomp!iance: Compliance:0.0%Better Than Code Maximum UA:234 Your UA:234 AssemblyGross Cavity Cont. Glazing, UA . or D.. Perimeter U-Factor Ceiling 1:Flat Ceiling or Scissor Truss 641 23.3 0.0 28 Ceiling 2:Cathedral Ceiling(no attic) 654 23.3 0.0 28 Wall 1:Wood Frame,16"o.c. 295 18.4 0.0 16 Window 1:Metal Frame:Double Pane with Low-E 33 0.500 17 Wall 2:Wood Frame,16"o.c. 255 18.4 0.0 13 Window 2:Metal Frame:Double Pane 12 0.500 6 Door 1:Glass 38 0.500 19 Wall 3:Wood Frame,16"o.c. 243 18.4 0.0 13 Window 3:Metal Frame:Double Pane 15 0.500 8 Door 2:Glass 16 0.500 8 Wall 4:Wood Frame,16"o.c. 250 18.4 0.0 14 Window 4:Metal Frame:Double Pane 24 0.340 8 Floor 1:All-Wood JoistlTruss:Over Unconditioned Space 1295 21.4 0.0 56 The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems,have been designed to meet the 2007 New York Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment;such plans or specifications are i mpliance ode. 4 - Name-Title Signa Date Project Title:KEHLE RESIDENCE(Revised) Report date:04/29/08 Data filename:C:\Program Files\Check\REScheck\KEHLE.rck Page 1 of 4 REScheck Software Version 4.1.3 Nr Inspection Checklist Date:04/29/08 Ceilings: ❑ Ceiling 1:Flat Ceiling or Scissor Truss,R-23.3 cavity insulation Corriments: ❑ Ceiling 2:Cathedral Ceiling(no attic),R-23.3 cavity insulation Comments: Above-Grade-Wills: ❑ Wall 1:Wood Frame,16"o.c.,R-18.4 cavity insulation -Comments: ❑ Wall 2:Wood Frame,16"o.c.,R-18.4 cavity insulation Comments: ❑ Wall 3:Wood Frame,16"o.c.,R-18.4 cavity insulation Comments: ❑ Wall 4:Wood Frame,16"o.c.,R-18.4 cavity insulation Comments: Windows: ❑ Window 1:Metal Frame:Double Pane with Low-E,U-factor.0.500 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 2:Metal Frame:Double Pane,U-factor.0.500 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 3:Metal Frame:Double Pane,U-factor:0.500 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: ❑ Window 4:Metal Frame:Double Pane,U-factor:0.340 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes No Comments: Doors: ❑ Door 1:Glass,U-factor.0.500 Comments: ❑ Door 2:Glass,U-factor:0.500 Comments: Floors: ❑ Floor 1:All-Wood JoistlTruss:Over Unconditioned Space,R-21.4 cavity insulation Comments: Project Title:KEHLE RESIDENCE(Revised) Report date: 04/29/08 Data filename:C:\Program Files\Check\REScheck\KEHLE.rck Page 2 of 4 Air Leakage: Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. Lj Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from insulation. Vapor Retarder: 0 Installed on the warm-in-winter side of all non-vented framed ceilings,walls,and floors. Materials Identification: 0 Materials and equipment are installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment are identified so that compliance can be determined. Li Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment have been provided. Li Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. El Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: Lj Supply ducts in unconditioned attics or outside the building are insulated to at least R-8. ❑ Return ducts in unconditioned attics or outside the building are insulated to at least R-4. ❑ Supply ducts in unconditioned spaces are insulated to at least R-8. Li Return ducts in unconditioned spaces(except basements)are insulated to R-2.Insulation is not required on return ducts in basements. Duct Construction: All joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastio-plus-embedded-fabric,or tapes.Tapes and mastics are rated UL 181A or UL 181 B. Exceptions: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). ❑ The HVAC system provides a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: Separate electric meters exist for each dwelling unit. Fireplaces: Ll Fireplaces are installed with tight fitting non-combustible fireplace doors. Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Building Code of New York State,the Residential Code of New York State or the New York City Building Code,as applicable. Service Water Heating: Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Circulating hot water pipes are insulated to the levels in Table 1. Circulating Hot Water Systems: Circulating hot water pipes are insulated to the levels in Table 1. Swimming Pools: All heated swimming pools have an on/off heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Project Title: KEHLE RESIDENCE(Revised) Report date: 04/29/08 Data filename:C:\Program Files\Check\REScheck\KEHLE.rck Page 3 of 4 Table 1:Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" Temperature("F) 170-180 .0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2.,Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range("F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Cooling-Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Project Title:KEHLE RESIDENCE(Revised) Report date: 04/29/08 Data filename: CAProgram Files\Check\REScheck\KEHLE.rck Page 4 of 4 43'-7" S88D°27'00'E 152.79' EXISTING WINDOW(TYP.) 0 I I 1 CLOSET 24" I LAUNDRY/UTILITY I O BATH 1 O LO O 1 0 N Cn 1 11' o vc'i BEDROOM 1 UT.CL. I co O EXISTING GARtAGETO BE CONVERTEED TO 100 1 cM STORY RESIDENCE q 1 1 Z 1 ' 1 !J 11' 5'-6- 6 o I �6; CLOSET °O�pO c? NEW 2X4 STUD � BATH 2 WALLS @ 16" 0 a CLOSET O.C.(TYP.) TRAY CEILING KITCHEN / �I / pNSpN RpPD RELOCATE EXISTING ® S�� WINDOW LIVING BEDROOM 2 ° N SITE PLAN 11' EXISTING DOOR TO REMAIN SURVEY BY JOHN C. EHLERS LAND SURVEYOR DATED 6/12/2002 NEW WINDOWS TO SCTM: 1000-103-10-12 MATCH EXISTING SCALE: 1"=40' a a FLOOR PLAN SCOPE OF WORK: -Installation of new interior walls,ceiling and flooring. -Installation of new windows and doors. -Installation of insulation in all walls,floors,and roof areas. -the installation of a new kitchen b6hrooms and associated.plumbingcrnd eVriCaC f USE IS UINI' I-A� � ` 'r 0t~JLEAD ( Jn`v'T�:PJT SL,"OPE "�� � t t, [� ;..;- � NOTES: C r�l'i; i;:; ' p + (1,�f,t�°CY Vv I B HIOU � CEt�"�TI. —I General : SL/ NI L}� i »�# t�4iRai >" � tF74 �.� EIZEED 2,i.PF 17�LEAF?: I I I 1 -Occupancy classification-Residential Group - 2-Type 5-Wood framed construction to be utilized. _ i ;>-3 C 3-Building height- 15'-1-1/4,fire area-1,296 s.ff. g —�.,- r I 4-The contractor is to verify all measurements in the field and any =_ Tnt discrepancies are to be brought to the attention off the Engineer IR, prior to construction. a T , .., 1_.,, D t1�`s s� — —�� ;1C.:. 5 .-v �. >AT act C" r- tr.C.. Fc;l FOUR C 11-C , 1. Y, ... n r'7 I t , -Ar'. r s.] n I fEs-.�,,� r"rr^r^: c�,ati..-• c. r,v,�.� Fi-t/'.: F PLt�,�..�.i;;� I i WINDOW SCHEDULE: Electrical Notes: �`�"'v���=` `' `' ���'`"' � I-3. INISULAI �' L CG`"' NOTE:ALL wlNDows To HAVE SCREENS. 1-All electrical work shall be installed by the owner, BE CO1. PI-E`u w R C.O. DESCRIPTION MANUFACTURER ROUGHOPENING ALL CONS T RLIC d TIO SHALL P,tEET REQUIREMENTS OF .E�"J DOUBLE HUNG WINDOW ANDERSON TW30e 3'-21/8-X 4'-8 7/a" 2-All electrical work shall be in accordance with the National Electric Code, THE CODES — — — I Y0111< STATE, NOT RES# ON05LE OR CASEMENT WINDOW ANDERSON C12 2-0-5/8'X 2'-0-5/8" Q[ 1r N OR CONSTRUCTIGN ERR RS. --------------------------------i 2❑ 3-AllsmokedetectorsshallbeinstalledinaccordancewithNFPA72andloca codes. 30 AWNING WINDOW ANDERSON AR31V Y-012"X T-5.12" FCTA!R s � - I Install Smoke Detectors in: C TERiT'II`L�A�Ti0° 1 r „R ,�„ ,,wit - I EXISTING ASPHALT SHINGLE ROOF TO REMAIN I I -All bedrooms ,�v�i� '�-3�,!lal��� , r0,�}I<�k�sr�T;,';.;Y�,3G !� �- x�.«, ,� ( I I I I I I I WINDOW NOTES: -Living room :,wl�l# : — � I I C � � I I 4-The detectors are to be wired to the building's main electrical service'and be equipped with battery back-up. I � I I 1 -Windows and doors are to be wood with double pane insulating high-performance low E glass with a max. U value of 0.34. Existing 5-The detectors shall be wired so that operation of any smoke detector shall cause the alarm to sound at the windows have a U value of 0.50. Irlrt:ae♦`gii•P^`°t!� �.h�+aT�r't)k� Yy I I others. 317 2-Windows and doors are to conform with the Allowable Air Infiltration 6-Carbon monoxide detectors mustbe,installed-ton each flo0Qcf'h0'.�uilding in accordance with Suffolk County I I I I I Rates specified in section 502.1.4.1 in the New York State Energy specifications. a� 1p n r:r�- ►,Ftr�`r F x .iv� TNT • ) )atiE "i;:r^ e tr EM Conservation Construction Code. " �, „'��'",`•°'�'"O` t! , M i t '.�iE &t'`Y as et.. a »— JNTk i n LO���Tfv� 3-Windows and doors are to be equipped with removable plywood 4 I ,�a �` fib. �< panels as shown in detail on S-5 or shall meet the requirements of the ,`�G. F ���y 0' �D. I I I Large Missile Test of ASTM E 1996 for 120 mile per hour wind loads. �Q� ��►3•CO�y� Plans are prepared by Condon Engineering,P.C. It is a violation of the O L1 I co b ? ©-� '� New York State Education Law,Article 145,Section 7209,for any person unless acting under the direction of a licensed Professional 4-Windows shown are manufactured by Anderson Englineer,Architect,or Land Surveyor,to alter any item in anyway.If Pf an iltem bearing the seal of an Engineer,Architect,or Land Surveyor is 5-Windows designated 1 have free openable area of 5.7 s.f, t9t `'` altelred,the altering Engineer,Architect,or Land Surveyor shall affix to the item his/her seal and the notation"Altered by"followed by his/her I 'S signature and the date of such alterations,and a specific description of L— _:j = = = _ _�— _ _ _  � � _ _ _ _ _ � Jy - - - - - - - � the altera tion. KEHLE RESIDENCE ROOF PLAN SCALE: 1/4"=1'-0" Condon Engineering, P.C. 635 STROHSON ROAD Drawn by:JJC 1755 Sigsbee Road CUTCHOGUE, NEW YORK Mattituck, New York 11952 Date: 10112/2005 (631) 298-1986 FLOOR PLAN EXISTING ASPHALT SHINGLE NEW RIDGE VENT ROOF TO REMAIN � NEW RIDGE VENT EXISTING ASPHALT SHINGLE ROOF TO REMAIN 0 NEW WINDOW TO MATCH EXISTING EXISTING SIDING TO REMAIN EXISTING SIDING TO REMAIN REMOVE EXISTING GARAGE DOOR AND SOUTH ELEVATION INSTALL NEW 2X4 EAST ELEVATION STUD WALL EXISTING ASPHALT SWINGLE ROOF TO REMAIN NEW RIDGE VENT NEW RIDGE VENT EXISTING ASPHALT SHINGLE ROOF TO REMAIN 0 o EXISTING SIDING Ll Z TO REMAIN � EXISTING SIDING EXISTING WINDOW TO TO REMAIN BE RELOCATED NORTH ELEVATION WEST ELEVATION - NE co � yk � �Q'�AOFESSI���� Plans are prepared by Condon Engineering,P.C. It is a violation of the New Yoork State Education Law,Article 145,Section 7209,for any person i unless acting under the direction of a licensed Professional Engineter,Architect,or Land Surveyor,to alter any item in anyway.If an item bearing the seal of an Engineer,Architect,or Land Surveyor is alteredl,the altering Engineer,Architect,or Land Surveyor shall affix to the item his/her seal and the notation"Altered by"followed by his/her signature and the date of such alterations,and a specific description of the alteration. KEHLE RESIDENCE SCALE: 1l4"44' Condon Engineering, P.C. 635 STROHSON ROAD Drawn by:JJC 1755 SigSbee Road CUTCHOGUE, NEWYORK Mattituck, New York 11952 BUILDING ELEVATIONS Date: 10/12/2005 (631) 298-1986 iPj & STRUCTURAL DETAILS NEW RIDGE VENT REMOVE EXIBSTING ASPHALT SHINGLES AS NECESSARY'TO INSTALL RIDGE STRAP EXISTING 2X8 RIDGE. $ A $ EEXI TTING2 66RO OOC. /" a" ' Framing Notes: TRAY CEILING'- `' ;. The contractor is to verify all measurements in tlhe field and any discrepancies are to be r J brought to the attention of the Engineer prior to construction. EXISTING T&G SHEATHING' _ — — — — — — — — — EXISTING ASPHALT ROOF —� ~n INSTALL BAFFLES EXIST.2X6 COLLAR TIES INSTALL 4 R-30 FIBERGLASS INSULATION Wood Framing BETWEEN RAFTERS NEW COLLOR TIES @ 16"O.C. — — — — — —1 R-19 FIBERGLASS INSULATION - __ °-: R-19 FIBERGLASS INSULATION 1 -All lumber is to be No.2 or better Douglas Fur Larch(N)with the following minimum specifications: IEXISTING 2X4 STUD WALL@ 16" �r.r INSTALL BAFFLES - I I O.C.WITH 1 T&G SHEATHING I I EXISTING SOFFET VENT BETWEEN RAFTERS Fb-825 psi NEW 2X8 CEILING Fv=95 psi 1/2"GYPSUM(TYP.) JOISTS @ 16"O.C, SHEATHING AND CEDAR SHAKE EXISTING 2X4 STUD WALL WITH T&G ((4)2X4 COLUMN I ( Fe perp=625 psi E= 1,600,000 SI EXISTING 2X6 STUD R-15 FIBERGLASS INSULATION NEW 2X4 STUDS @ 16" SIDING p (FROM ABOVE WALL WITH T&G O.C.&3"0 STEEL (4)2X4 COLUMN NEW 2X4 STUD WALL I I SHEATHING AND CEDAR COLUMNS(SEE FRAMING 2-All Laminated Veneer Lumber is to have the following minimum specifications: FROM ABOVE — Q16"O.C.(TYP) — — — — — — J I SHAKE SIDING PLAN FOR LOCATIONS) — - R-21 FIBERGLASS INSULATION R-15 FIBERGLASS INSULATION Fb=2,900 psi — .— — — — — — NEW 2X8 FLOOR JOISTS @ 16"O.C. NEW 3/4"PLYWOOD Fv=290 psi sI SUBFLOOR L Fc perp=650 psi EXISTING CONCRETE: (4)2X4 COLUMN I� FOOTING FROM ABOVE I E=2,000,000 psi I f I 1X4AC SLEEPERS ._.... :4.____._..-----=---=�=::._..:.__- ---.,_---------------�-__I:_:�•,�---,_--_---------------------- �'.. EXISTING 2X8 SILL-CONTINUOUS. i " ?.�EXJSTING 8"CMU Q EXISTING CONC.SLAB FLOOR - ; �'. ' 3-All beams fabricated with multiple Laminatedl Veneer Lumber boards are to be EXISTING FLOORING TO REMAIN I I INSTALL NEW 1/2"X 12 ANCHOR FO)UNDATION WITH 8" o�3'-6'O.C.MAX. _ �• 4 BOLTS @ 6-0"O.C. FO)OTING SECTION A-A nailed/bolted in accordance with the manufactuner's specifications. ■ 1 " o I I 1/4-1 0 4-All straps,connectors,plates,bolts, nails, etc. are to be galvanized or stainless steel. Designated connectors,strap etc.on these drawings are made by Simpson unless indicated otherwise.All connectors,straps etc. are to be nailed/bolted in accordance with the manufacturer's specifications. I � o • I 5-All floor sheathing is to be s/"AC type plywood,tongue and groove,with an APA span 0 I EXISTING 2X6 ROOF rating of 48/24. Floor sheathing shall be glued and nailed to the floorjoists. RAFTERS @ 16"O.C. NEW(2)1.75X 14 LVL GIRDER 6-Solid blocking is to be installed every 8'max or mid span of all floor&ceiling joists. 1X4 ACQ SLEEPERS @ 3-6"O.C.MAX.(LAY FLAT) O I 7-Blocking is to be installed at all point load bearing points, NEW TRUSS(SEE °® DETAIL SHEET S•2) ���. NEW 2X8 CEILING I Insulation note:I CONNECT NEW CEILING JOISTS @ 16"O.C. — — — — — — � I JOISTS WITH SIMPSON ANGER 1 -R-19 insulation to be installed in cathedral ceilings only. R-30 to be installed in all ceiling LUS 28 JOIST HANGERS 9 Y• 9 — — — NOTE:STRAPS MAYBE areas. I � PLACED OVER ROOF SHREATHING. EXISTING(2)2X8&(2)2X4 EXISTING 2X6 STUD WALL @ 16" I I GIRDER TO BE REMOVED I O.C.WITH 1"T&G SHEATHING NEW RIDGE VENT Simpson ach Ra Ridge I Strap at each Rafter REMOVE EXISTING ASPHALT SHINGLES AS RAFTER TOP PULE NECESSARY TO INSTALL RIDGE STRAP �� EXISTING 2X8 RIDGE. TOPPIAIE EXISTING 2X6 ROOF '� - < HEADER — — — -- — — — — — RAFTERS @ 16"O.C. I \ h —,_ �— —L_ I Simpson each R Rafter Strap „EFDER % �' ( at each Rafter Tail EXISTING6X6COLUMN _ _ FROM ABOVE Simpson MTS30 Rafter Strap EXISTING T&G SHHEATHING = - - ' - --- -- -- =� =, ::::. Typical Rafter EXIST,2X6COLLARTIES - NEW 2X8 CEILING Strapping Detail at each Rafter Tail ., JOISTS @ 16"O.C. Typical Rafter EXISTING ASPHALT Roo)F 2X4 BRACING AT FLOOR PLAN R-30 FIBERGLASS i EACH CEILING JOIST R-30 FIBERGLAA S,\ Strapping Detail INSULATION - INSULATION R-19 FIBERGLASS INSULATION $ A $ r INSTALL BAFFLES NEW 2X8 CEILING JOISTS @ 16"O.C.J BETWEEN RAFTERS XISTING SOFFET VENT EXISTING(2)2X8&(2)2X4 GIRDER TO BE REMOVED EXISTING 2X4 STUD WALL WITH SHEATHING AND CEDAR SHAKE EXISTING 2X6 STUD R-15 FIBERGLASS INSULATION NEW 2X4 STUDS @ 16" SIDING WALL WITH T&G O.C.&3"0 STEEL SHEATHING AND CEDAR COLUMNS(SEE FRAMING SHAKE SIDING PLAN FOR LOCATIONS) SIMPSON R-21 FIBERGLASS INSULATION R-15 FIBERGLASS INSULATION (2)2)K8 HEADER (2)2X8 HEADER NEW 3/4"PLYWOOD L30 ORA21 NEW 2X8 FLOOR JOISTS @ 16"O.C. SUBFLOOR (2)2X8 HEADER (2)2X8 HEADER STRAP (2)EACH STUD Typical Wall and Sill ' i Strapping Detail - - - - - - - -- - - - -------__.__-------------___.__-----____... O EXISTING 8"CMU 1X4ACQSLEEPERS r" 1 �:_•. " @ 3'-6"O.C.MAX. EXISTING CONC,SLAB FLOOR @� EXISTING 2X8 SILL-CONTINUOUS. FOUNDATION WITH 8 INSTALL NEW 1l2"X 12"ANCHOR FOOTING SECTION B-B o BOLTS @ 6-0-O.C. 1/4"=1'-0" BLEARING WALL Z J (2)2X8 HEADER v K co FRAMING N NEW(2)1.75 X 14 LVL GIRDER CONTINUOUS NEW(2)1.75 X 14 LVLGIRDER (4)2X4 COLUMN 3"No.8 SCREWS 12"O.C. LIGHT WOOD-FRAME WALL (4)2X4 COLUMN BEARING WALL 12'-5" I BEARING WALL EXTEND TO ROOF RAFTERS •(4)2X4 COLUMN I WASHER(TYP.) Design Loads: I -Roof-Live Load-35.5 psf b Y"PLYWOOD Based on ASCE-7 and Pg=45 psf (2)2X8 HEADER I o per Figure R301.2(5) — --------------- W --------------i GLAss -Dead Load-15psf CD o o o -1st Floor -Live Load-40 psf 0 -Dead Load-15 psf O NE I Z PLASTIC-COATED PERMANENT WOOD j";r o '� I W SCREW ANCHORS _ (2)2X8 HEADER to Z I � -Wind Loads-120 mph-ASCE-7 2)2X8 HEADE r 0 i GLASS MWFRS-Method 2'co 7 Component and EXISTING 2X8 RIDGE EXISTING 2X8 RIDGE Y"PLYWOOD SIMPSON LSTA36 WFCM TABLE 3.8 Cladding-Details from t O O STRAP BEARING WALL I ® FRAMING TRAY CEILING sEE Design Criteria-NYS Residential Code R301.2.1.1 and utilized EXTEND TO CEILING � DETAIL g Q�R ���•� JOISTS o o A the methods and procedures stipulated in Chapter 2 Engineered QFESS1 Design and Chapter 3 Prescriptive Design in the American Forest W and Paper Association Wood Frame Construction Manual for One WASHER(TYP.) Typical Window and Door Header and Two Family Dwelling Units- High Wind Addition and ASCE7. --------------- --- ------------ (2)2X8 HEADER PLYWOOD OPENINGS PROTECTION; THICKNESS DEPENDS ON WINDOW Strapping Detail Each Corner CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA OPENING WIDTH(I) 3"No.8 SCREWS 12"O.C. NTS Ground Snow Load Wind Speed Seismic Weathering Frost Line Termite Decay Winter Design Ice Shield Flood Hazard EXISTING 6X6 I DETAIL A-TYPICAL ATTACHMENT OF Depth Temp. Underlayment COLUMNS PLYWOOD OPENINGS PROTECTION TO Required WOOD-FRAME BUILDING 45 psf 120 mph B Severe 36 in. Moderate Slight to 11°F Yes (3)2X8 HEADER (3)2X8 HEADER (3)2X8 HEADER to Heavy Moderate EXISTINGGIRDER _ Alternate to 120 MPH Certified NOTE: IN LIEU OF SCREWS,LUGS Window Installation WITH NUTS AND WASHERS MAY BE USED Plans are prepared by Condon Engineering,P.C. It is a violation of the New KEHLE RESIDENCE ROOF PLAN Plywood Panel Window and Door York State Education Law,Article 145, Section 7209,for any person unless SCALE:AS SHOWN Condon Engineering, P.C. 635 STROHSON ROAD acting under the direction of a licensed Professional Engineer,Architect,or Protection for Wood Framed Land Surveyor,to alter any item in anyway.If an item bearing the seal of an CUTCHOGUE, NEWYORK Engineer,Architect,or Land Surveyor is altered,the altering Engineer, Drawn by:JJC 1755 Sigsbee Road B " Architect,or Land Surveyor shall affix to the item histher seal and the notation MattituCk, New York 11952 FRAMING PLAN & u i Id n s "Altered by"followed by his/her signature and the date of such alterations,and Date: 10/12/2005 (631)298-1986 N.T.S. a specific description of the alteration. DETAILS PLAN Bathroom Anti Freeze Type = Hose Bibb Kitchen Dish Washer _ U U � � 4 "HW = c� 4 'CW 4 CW Water Main Valves e/w 1 Drains Existing public waterline Indirect Fired Water Heater Building Shut I OftValve n Crawl Spacae Drain 3"PVC Vent 2"PVC Vent \ I 3"PVC Vent Table 3.1 Nailing Schedule(Wood Framed Construction Manual 11995 SBC High Wind Edition,Page 110) 2"PVC 12"PVC Joint Description Number of Nails Nail Spacing Vent I Vent ROOF NAILING i I Rafter to Top Plate(Toe-nailed) 4-8d per rafter Kitchen I Notes: Ceiling Joist to Top Plate(Toe-nailed) 4-8d per joist Ceiling Joist to Parallel Rafter(Face-nailed) 8-16d each lap Co I I General Ceiling Joist Laps Over Partitions(Face-nailed) 8-16d each lap 0 Collar Tie to Rafter(Toe-nailed) 2-1 Old per tie Blocking to Rafter(Toe nailed) 2-8d each end *Owner to select fixture model,make,and color. Rim Board to Rafter End Nailed 2-16d each end CO 2 PVC 1st Floor Bathroom *All work and materials shall be in accordance with the New York State Building Code and Local Plumbing Codes. WALL FRA�NING 2"PVC Top Plate to Top Plate(Face-nailed) 2-16d(1) per foot Ya"Pitch Top Plates at Intersections(Face-nailed) 4-16d joists-each side *All water lines within the buildings are to be Type"L"copper tubing all water lines routed below ground are to be 1 CO Type K copper..All solder joints are to be made with lead free solder in accordance with local and State Codes. Stud to Stud(Face-nailed) 2- 16d 24"o.c. V Header to Header(Face-nailed) 16d 16"o.c. along edges House Trap Vent CO House Trap Vent CO *All horizontal waste and vent runs of 2 inch waste pipe are to pitched at Ya inch per foot.The 3 and 4 inch waste Top or Bottom Plate to Stud(End Nailed) 2-16d per 2x4 stud and vent piping should also have a Y inch per foot itch wherever possible with a minimum itch of Y inch per foot. p p g p p p p a p 3-16d per 2x6 stud Co CO *Provide all vents shown in the drawings, as required by the Plumbing Code,and as necessary to prevent siphonage 4-16d per 2x8 stud 4"PVC or back pressure on the trap seals.House Trap House Trap Bottom Plate to Floor Joist, Band Joist, End joist or Blocking(Toe-nailed) 2-16d (1,2) per foot �� *Provide cleanouts as shown in the drawings. Provide 18 inch clearance at all trap locations. FLOOR FRAMING Joist to Sill,Top Plate or Girder(Toe-nailed) 4-8d per joist roposed 4"Cast Iron roposed 4"Cast Iron 1 Through Foundation Through Foundation *All waste and event pipes and water supply pipes shall be supported by pipe hangers.The hangers shall be installed Bridging to Joist(Toe-nailed) 2-8d each end at a maximum spacing of 4 feet.All vertical runs are to be supported as required by local and State Codes. Blocking to Joist(Toe-nailed) 2-8d each end Proposed 4"to residential sanitary system roposed 4"to residential sanitary system Blocking to Sill or Top Plate(Toe-nailed) 3-16d each block *All water supplly piping is to be insulated with 1 inch thick cylindrical molded glass fiber type insulation with a 3 Y2 lb.density. Ledger Strip to Beam(Face-nailed) 3-16d each joist Joist on Ledger to Beam(Toe-nailed) 3-8d per joist * Pressure Tesit all waste and vent piping at the completion of rough in.Tightly close all openings in the piping system, Band Joist to Joist(End-nailed) 3-16d per joist PLUMBING RISER DRAWING and fill with water to a point of overflow,but not less than 10 foot head of water.The water level is to remain level fora Band Joist to Sill or Top Plate(Toe-nailed) 2-16d (1) per foot minimum of 15 rminutes to be considered leak free. ROOF SHEATHING *All water supplly piping is to be pressure tested.The initial test is with no connection to the fixtures and is to be done Structural Panels 8d (Detail sheet S-3) by capping all olpenings and pressurizing the piping system with compressed air to a minimum pressure of 150 psig. The pressure is to monitored for 2 hours and will be considered to be leak free if the pressure remains constant during the test period.jAfter successful completion of this test,the fixtures are to be connected and the system is to be tested at a pressure of 90 psig for a period of 2 hours. CEILING SHEATHING *The water suplply system shall be cleaned by filling the system with water/chlorine solution with at least 50 ppm of chlorine. Gypsum Wallboard 5d coolers 7"edge/10"field WALL SHEATHING The piping is to isolated and allowed to stand for a period of 24 hours.The system is to be flushed at the completion of the test. Structural Panels 8d 6"edge/12"field *Shower and tulb supply valves are to be temperature-actuated flow reduction type devices. Gypsum Wallboard 5d coolers 7"edge/10"field *All foundation wall penetrations are to be sealed with concrete and water proofed on the exterior side of the penetration. Water supply and gas line penetrations are to be equipped with sleeves, FLOOR SHEATHING Structural Panels *All gas appliances are to be equipped with gas cocks. 1"or less 8d 6"edge/12"field *Install ball valvres at the locations shown on this drawing.Also installed gate valves for hot and cold water at all fixtures. All 0C N (1) Nailing requirements are based on wall sheathing nailed 6"on-center at the panel edge. If wall sheathing is nailed 3" exposed water supply and waste piping to fixtures and the valves are to be 67%brass pipe chromium plated. on-center at the panel edge to obtain higher shear capacities, nailiing requirements for structural members shall be doubled,or alternate connectors,such as shear plates,shall be used to maintain load path. *Run water supiply piping to fixtures concealed within walls and horizontally to fixtures.All pipes are to be equipped with "' (2)When wall sheathing is continuous over connected members,Ithe tabulated number of nails shall be permitted to be chrome plated eschuteons at all exposed floor and wall penetrations. sir reduced to 1 -16d nail per foot. Plans are prepared by Condon Engineering,P.C. It is a violation of the New KEH LE RESIDENCE York State Education Law,Article 145, Section 7209,for any person unless SCALE: N.T.S. o n d o n Engineering, P. 635 STROHSON ROAD acting under the direction of a licensed Professional Engineer,Architect,or Land Surveyor,to alter any item in any way.If an item bearing the seal of an CUTCHOGUE, NEW YORK Engineer,Architect,or Land Surveyor is altered,the altering Engineer, Drawn by:JJC 1755 Sigsbee Road Architect,or Land Surveyor shall affix to the item his/her seal and the notation Mattituck, New York 11952 PLUMBING R I SOR & "Altered by"followed by his/her signature and the date of such alterations,and Date: 9/25/2006 (631)298-1986 a specific description of the alteration. NAILING SCHEDULE GENERAL NOTES: ASAFETY NOTES: RESIDENTIAL RENOVATION & CONSTRUCTION 1 . GENERAL: ALL WORK TO BE COMPLETED IN ACCORDANCE WITH THE TOWN OF SOUTHOLD, NEW YORK, BUILDING CODE, AND CC, NTRACTOR Fin M General Notes: REGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION. ; " 141� �a� Wood: 1 . All studs to be SPF #2 or better, and all other structural wood to be Douglas Fir J#2 or better. 2. FIRE SAFETY: A ALL BUILDING MATERIALS WHICH ARE STORED AT THE SITE OR ANY AREA OF THE BUILDING ARE TO BE STORED IN A _ D °A°K ASSOCIATES LLC A.2. All structural wood shall be in accordance with the national design specifications for- wood construction — latest edition. residential & commercial design "engineering o consulting B. LOCKED AREA. GENERAL NOTES: 3. Nailing schedule shall be in accordance with the specified code. C. ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION 4. Pre—manufactured trusses. D. ALL FLAMMABLE MATERIALS TO BE KEPT TIGHTLY SEALED IN THEIR RESPECTIVE MANUFACTURER'S CONTAINERS. SUCH 506MiainStreet phone: 1631J767-6071 1 • ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE TOWN OF SOUTHOLD, SUFFOLK COUNTY, NEW YORK, BUILDING CODE, a. All trusses shall be "shaped" as shown on architectural cross sections. Westhampton Beach,New York 11978 fax: (631)466.3354 FIRE DEPARTMENT RULES AND REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND THE BEST TRADE PRACTICES. b, Trusses shall bear a boca number and shall be manufactured by a registered manufacturer. MATERIALS ARE TO BE KEPT AWAY FROM HEAT. 2. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF 5. Erect and brace trusses in accordance to truss plate institute recommendations. E. ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN ADEQUATELY VENTILATED SPACE. E End Design ignAss CArm8888@aol.com com BUILDINGS, OBTAIN ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, F. ALL ELECTRICAL POWER TO BE SHUT OFF WHERE THERE ARE EXPOS Deerkoski,Arm&Kehl Associates,LLCoformerlyEastEndDesignAssociates,LLC AND PAY ALL FEES REQUIRED BY THE GOVERNING BODY OF THE TOWN OF SOUTHOLD, NEW YORK, AGENCIES 6, Plywood sheathing. EXPOSED CONDUITS. G. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS. OWNERSHIP & USE OF DOCUMENTS: 3. MINOR DETAILS NOT US SHOWN OR SPECIFIED, BUT REQUIRED FOR PROPER CONSTRUCITON OF ANY PART OF THE WORK a. All plywood shall be in accordance with the American Plywood Association (AFPA) specifications. CONTRACTOR, AT ALL TIMES, TO ENSURE THERE IS NO NATURAL GAS LEAKAGE IN THE BUILDINGS, OR ANY FLAMMABLE These drawings and specifications including the b. Plywood sheathing shall be continuous over two or more spans with grain of` face plys across supports ;ideas, design and arrangements represented SHALL BE INCLUDED AS IF THEY WERE IINDICATED IN THE DRAWINGS. corporation or equal. GAS TO BE USED DURING CONSTRUCTION. therein, are the property of D.A.K. ASSOCIATES, 4. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH THE STIPULATIONS OF LOCAL AUTHORITIES, AND OWNER. LLC. No part thereof shall be copied, disclosed 7. All sills shall be pressure preservative treated (.4 PSF retention) SYP #2 or better. 3. DUST CONTROL: to) others or used in connection with any work or project other than for which they have been 5. THE CONTRACTOR SHALL BE RESPONSIBILE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCTION AREA, THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORING AND BRACING FOR ALL STRUCTURAL OR 8. Design values: A. DEBRIS, DIRT AND DUST TO BE KEPT TO A MINIMUM AND CONFINED TO THE IMMEDIATE CONSTRUCTION AREA. prepared without written consent. REMOVAL TASKS. THE CONTRACTOR THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY a. Framing Lumber: DF (north) No. 2 or better B. CONTRACTOR TO ISOLATE CONTRUCTION AREA FROM OCCUPIED BUILDING AREA BY MEANS OF TEMPORARY PARTITIONS OR OR DURING THE EXECUTION OF THE WOIRK. E = 1,600,000 PSI Fv = 95 PSI C. HEAVY DROP CLOTHS. 6. THE CONTRACTOR SHALL LAY OUT HIS OWN WORK, AND SHALL AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES: Fb — 825 PSI DEBRIS, DIRT, AN DUST TO BE CLEANED UP AND CLEARED FROM THE BUILDING SITE PERIODICALLY TO AVOID EXCESSIVE PLUMBING, ELECTRICALS, ETC. 9. Design values: ACCUMULATION. 7. PLUMBING WORK SHALE_ BE PERFORMED BY PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN THROUGH a. Laminated Veneer Lumber (LVL): THE DEPARTMENT OF BUILDINGS ALL REQUIRED PERMITS, INSPECTIONS AND REQUIRED SIGN OFFS. E = 1,900,000 PSI 4. NOISE AFTER HOURS: Fv = 285 PSI 8. ELECTRICAL WORK SHALL BE PERFORMED BE PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN Fb = 2600 PSI A. CONSTRUCTION OPERATIONS WILL BE CONFINED TO NORMAL WORKING HOURS: 8AM TO 6PM, MONDAY TO FRIDAY, THROUGH THE BUREAU OF ELECTRICAL (CONTROL ALL REQUIRED PERMITS, INSPECTIONS AND REQUIRED SIGN OFFS. B. EXCEPT LEGAL HOLIDAYS. 9. THE CONTRACTOR SHALL DO ALL CUTTINJG, PATCHING, REPAIRING AS REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. NOTE CONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM ALL AFFECTED PARTIES TO WORK OTHER THAN REGULAR HOURS. DRAWINGS, AND ALL OTHER WORK THAT MAY BE REQUIRED TO COMPLETE THE JOB. DEERKOSKI, ARM & KEHL ASSOCIATES, LLC, AND THERE ASSOCIATED ENGINEER ARE NOT OVVERSEEING THE CONSTRUCTION OF THIS BUILDING. THE USE OF THESE DRAWINGS BY ANY CONTRACTOR, SUBCONTRACTOR, BUILDER„ TRADESMAN OR WORKER SHALL 5 CONSTRUCTION OPERATIONS WILL NOT INVOLVE INTERRUPTION OF HEATING, WATER, OR ELECTRICAL SERVICES TO THE OWNER. 10. ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONCEALMENT AND SHALL BE PROPERLY CAPPED OR PLUGGED. INSTIGATE A HOLD HARMLESS AGREEMENT BETWEEN THE DRAWING USER AND DEERKOSKI, ARZM & KEHL ASSOCIATES, LLC. CONSTRUCTION WORK WILL BE CONFINED TO THE WORK ISSUED, AND WILL NOT CREATE DUST, DIRT, OR OTHER SUCH 11 . ALL DIMENSIONS ARE ESTABLISHED FROW THE FINISH LEVEL OF THE FIRST FLOOR. VARIATIONS TO THE HEIGHT OF THE FINISH THE USER SHALL IN FACT AGREE TO HOLD DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. HAFRMLESS FOR ANY RESPONSIBILITY IN INCONVENIENCES TO THE OTHER NEIGHHBORS. LEVEL OF THE FIRST FLOOR ARE TO RE REVIEWED FOR APPROVAL BY THE OWNER AND DAK ASSOCIATES, LLC. NO CONSTRUCTION REGARD TO CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES A^ND FOR ANY SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK AND FURTHER SHALL HOLD THE ARCHITECT HARZhALESS FOR COSTS AND PROBLEMS 6 SPECIAL SAFETY NOTES WILL BE ALLOWED TO COMMENCE UNTIL THIS HEIGHT IS APPROVED. ARISING FROM THE NEGLIGENCE OF THE CONTRACTOR, SUBCONTRACTOR, TRADESMAN, OR WORKMAN. THE USE OF THESE DRAWINGS ALL CONTRACTORS AND THEIR REPRESENTATIVES WORKING ON THIS PROJECT SHALL AT ALL TIMES PRIOR AND DURING THE COURSE 12. THE CONTRACTOR IN COORDINATING THE WORK WILL REPORT ANY DISCREPANCIES TO THE ENGINEER'S ATTENTION FOR IMMEDIATE ALSO IMPLIES THAT DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. SHALL TAKE NO RESPONSIB311_ITY FOR THE PLAN USER'S FAILURE TO OF THEIR ACTIVITY BE RESPONSIBLE FOR THE SAFETY OF THEIR EMPLOYEES AS WELL AS OTHERS AND IN THE CARE OF THE RESOLUTION. CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWING OR CONTRACT DOCUMENTS. PROPERTY. EACH AS REPRESENTATIVES OF THEIR EMPLOYEES SHALL ASCERTAIN THAT THE CONDITIONS UNDER WHICH THEY WILL BE REQUIRED TO ACCOMPLISH THEIR WORK ARE SAFE WITHIN GOOD SAFETY PRACTICES AND MEET ALL CONCERNED REGULATIONS OF 13. THE CONTRACTOR WILL COORDINATE THE: ROUTING AND PLACEMENT OF ALL UTILITY LINES WITH THIS AND RELATED SITE WORK, AND THE OCCUPATIONAL SAFETY AND HAZARD ACT OR OTHER GOVERNING REGULATIONS. THE BEGINNING OF WORK BY A CONTRACTOR WORK: NOTES: SHALL INDICATE SATISFACTION CONCERNING SAFETY AND FULL RESPONSIBILITY FOR ACCIDENTS OR DAMAGE. IF UNSATISFIED, THE HE WILL BE RESPONSIBLE FOR ALL DISCONNECTIONS, RECONNECTIONS, AND STARTUPS. DOCUMENT NOTES CONTRACTOR SHALL INDICATE WHATEVER ACTION NECESSARY, OR RENDER SAFETY CONDITIONS FOR LIFE AND PROPERTY AS ARE 14. THE CONTRACTOR WILL COORDINATE THE: ROUTING AND PLACEMENT OF ELECTRICAL, PLUMBING, AND HVAC EQUIPMENT WITH THESE CONSTRUCTION DOCUMENTS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY OTHERS. ALSO, THE CLIENT AGREES, TO THE FULLEST EXTENT OF THE LAW, TO INDEMNIFY AND HOLD DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. HARMLESS RELATED TO HIS ACTIVITY, IF THE WORK OF OTHER PARTIES OUTSIDE OF THE ORGANIZATION IS UPON INSPECTION FOUND AT ANY TIME TO BE UNSAFE, HE SHOULD STOP WORK IMMEDIATELY AND NOTIFY THE GENERAL CONTRACTOR, DAK ASSOCIATES, LLC, OR ARCHITECTURAL FEATURES AND STRUCTUIRE. ANY CONFLICTS WILL BE BROUGHT TO THE ENGINEER'S ATTENTION FOR IMMEDIATE FROM ANY CLAIM, LIABILITY OR COST INCLUDING REASONABLE ATTORNEY'S FEES AND COSTS; OF DEFENSE, FOR THE INJURY OR OWNER. THE BEGINNING OF WORK SHALL INDICATE SATISFACTION WITH CONDITIONS AND ACCEPTANCE OF THESE REQUIREMENTS. RESOLUTION. ECONOMIC LOSS ARISING OR ALLEGEDLY ARISING OUT OF THE PROFESSIONAL SERVICES PROVIDED UNDER THIS AGREEMENT. 7 PROVIDE SINGLE AD MULTIPLE—STATION SMOKE ALARMS AS WELL AS CARBON MONOXIDE DETECTORS SINGLE AND MULTIPLE—STATION IN ACCORDANCE WITH STATE, FEDERAL, AND LOCAL CODES, CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND WIND SEISMIC SUBJECT TO DAMAGE FROM WINTER ICE SHIELD WORK P ER FO R M E D SNOW DESIGN FROST LINE DESIGN UNDERLAY— FLOOD WIND EXPOSURE LOAD SPEED m h CATEGORY WEATHERING DEPTH TERMITE DECAY TEMP. MENT REQUIRED HAZARDS CATEGORY ROOF DRAINAGE CALCULATIONS. 20 Ibs/sqft 120 (rnph) C SEVERE S—O" MODERATE TO HEAVY SLIGHT TO MODERATE 11 degrees YES 1984/1998 C DESIGN CRITERIA CONSTRUCTED A PERGOLA ON REAR YARD OF RESIDENCE PRESCRIPTIVE DESIGN MINIMUM.'. UNIFORM DISTRIBUTED LIVE LOADS LOCATED AT 635 S TR O H S O N ROAD , C U TC H O G U E NEW YORK ROOF AREA IS NEGLIGIBLE AS THE CONSTRUCTION IS (in pounds per square foot) AN OPEN ROOF WHICH COLLECTS NO RAIN WATER. USES(s) AND OCCUPANCY CLASSIFICATION(s) USE LIVE LOAD DEAD LOAD PROPERTY IS FLAT AND ANY RUN-OFF WILL BE COLLECTED USE OCCUPANCY EXTERIOR BALCONIES 60 10 i ON SITE. RESIDENTIAL R-3 DECKS (f) 40 10 TYPE OF CONSTRUCTION (CHAPTER 6) PASSENGER VEHICLE GARAGES (a) 50 (a) 10 TYPE GROUP ATTICS WITHOUT STORAGE (b,e) 10 10 V B ATTICS WITH STORAGE (b,e) 20 10 PROJECT: HEIGHT AND FIRE AREXA ROOMS OTHER THAN SLEEPING ROOMS 40 10 HEIGHT FIRE .AREA SLEEPING ROOMS 30 10 AS BUILT TO THE HEIGHT, BUILDING. THE VERTICAL DISTANCE STAIRS FROM GRADE PLANE TO 40 (c) 10 THE AVERAGE HEIGHT UNLIMITED AREA OF THE HIGHEST ROOF 3 ST-CRY GUARDRAIL AND HANDRAILS (d) 200 (c) 10 SURFACE = N/A AS PER T/ABLE 503 E INY AS PER SECTION 502 OF ROOF 30 10 THE BUILDING CODE OF NEW YORK STATE. RESIDENCE a) ELEVATED GARAGE FLOORS SHALL BE CAPABLE OF SUPPORTING A 2,000— TOTAL HEIGHT FROM RIDGE TO GRADE N/A POUND LOAD APPLIED OVER A 20—SQUARE—INCH AREA. 635 STROHSON ROAD b) NO STORAGE WITH ROOF SLOPE NOT OVER 3 UNITS IN 12 UNITS. CUTCHOGUE, NEW YORK LUMBER SPECIES AND GRADE c) INDIVIDUAL STAIR TREADS SHALL BE DESIGNED FOR THE UNIFORMLY DISTRIBUTED LIVE LOAD OR A 300—POUND CONCENTRATED LOAD ACTING OVER AN AREA OF 4 SQUARE INCHES, WHICHEVER PRODUCES THE GREATER ALL HOUSE FRAMING MATERIAL D1OUGLAS FIR — LARCH #2 AND BETTER STRESSES. DRAWING 1 I I LE: ALL EXT. DECK FRAMING MATERIAL C,CA NC PINE #2 AND BETTER d) A SINGLE CONCENTRATION WITH WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH SECTION R802.10,1. '�I��� e) SEE SECTION R502.2.1 FOR DECKS ATTACHED TO EXTERIOR WALLS D TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE ET: AREAS OF STRUCTURE MINIMUM SPECIFIED S ISSUED FOR: DATE: COMPRESSION STRENGTH (a) (fc) BLDG.DEPT. CRAWL SPACE NA TYPE OR LOCATION OF CONCRETE CONSTRUCTION WEATHERING POTENTIAL TOWN 01 SOL'THDL BASEMENT NA FIRST FLOOR NA SEVERE (b) SECOND FLOOR NA BASEMENT WALLS, FOUNDATIONS AND OTHER THIRD FLOOR NA CONCRETE NOT EXPOSED TO THE WEATHER 2,500 (c) SEAL: DATE: BALCONY NA FIRE BLOCKING IS TO BE INSTALLED TO MEET OR EXCEED ALL REQUIREMENTS OF THE BUILDING CODE LOFT NA OF NEW YORK STATE, AND THE AMERICAN FOREST & PAAPER ASSOCIATION (AF & PA) WOOD FRAME June 3rd, 2013 ATTIC (HOUSE)(c) NA BASEMENT SLABS AND INTERIOR SLAB ON 2,50o c CONSTRUCTION MANUAL WFCM FOR ONE AND TWO FA,t�11LY DWELLINGS, 2001 SBC HIGH WIND EDITION. OC PROJECT NO: ATTIC HOUSEb NA GRADE, EXCEPT GARAGE FLOOR SLABS ( ) ( ) COPYRIGHT 2011 D.A.K ASSOCIATES, LLC. 965-2013 GARAGE NA NO SUBSTITUTIONS DRAWN BY: NOTE: ALL ROOMS MEET OR EXCEED THE NYS. STANDARDS NO FLOOR PLANS AND ELEVATIONS ARE PROTECTED ATTIC (GARAGE)(a) NA BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS AND All Framing Hardware Shown on these Plans, I BDK FOR THE NATURAL LIGHT AND VENTILATION REQUIREMENTTS, UNDER FEDERAL COPYRIGHT LAW. pF NEp BONUS ROOM NA OTHER VERTICAL CONCRETE WORK EXPOSED TO THE WEATHER 3,000 (d) Unless Otherwise Indicated, Is Simpson Strong— ��� �) CHECKED BY: PLANS MAY NOT BE REPRODUCED WITHOUT ti �, DF PERGOLA 313 sq. ft. Tie. No Substitutions are Approved or Authorized. 5 ALL SIMPSON HANGERS HAVE BEEN CERTIFIED BY AN ENNGINEER TO HAVE A CAPACITY WRITTEN AUTHORIZATION. �� �r, i JJD SOUTHERN DECK NA 4 ��c )7 SHEET NUMBER: EQUAL TO OR GREATER THAN THE REQUIRED AMOUNT CAALCULATED FOR EACH CASE. ALL PLANS AND DESIGNS ARE THE SOLE PROPERTY OF — " WESTERN DECK NA PORCHES, CARPORTS AND STEPS EXPOSED TO Due to the Relationships of Framing Hardware ;`'r` THE WEATHER, AND GARAGE FLOOR SLABS 3,500 (d) P g D.A.K. ASSOCIATES LLC. c � ") FRONT PORCH NA SHEATHING NOTES: to the other Components of the Structure, any SIDE PORCH NA THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE L z,, ALL SHEATHING TO BE NAILED IN ACCORDANCE WITH THEE NAILING SCHEDULE OF THE AMERICAN FOREST Framing Hardware Substitutions will Render u� n, A PLANS IS LICENSED EXCLUSIVELY TO THE BUYER. �p �� ; � ' POOL HOUSE CABANA NA & PAPER ASSOCIATION (AF & PA) WOOD FRAME CONSTRZUCTION MANUAL (WFCM) FOR ONE AND TWO These Plans Null and Void, and will Result in the 072 FOR SI: 1 POUND PER SQUARE INCH + 6.895 kpa G1 UNCOVERED ENTRANCES NA (a) AT 28 DAYS PSI FAMILY DWELLINGS, 2001 SBC HIGH WIND EDITION. Installer / Contractor Assuming Responsibility for Acceptance of these drawings does not authorize the right to build without (b) SEE TABLE R301.2(1) FOR WEATHERING POTENTIAL the Design and Performance of the Entire System. the authorization of local governing agencies, such as Suffolk County Dept. �! DOB NUMBER; OF (a) WITHOUT STORAGE (c) CONCRETE IN THESE LOCATIONS THAT MAY BE SUBJECT To FREEZING AND THAWING DURING (1) SHEATHING TO BE NAILED TO CCA SILL (b) WITH STORAGE CONSTRUCTION SHALL BE AIR—ENTRAINED CONCRETE IN ACCORDANCE WITH FOOTNOTE (d) (2) SHEATHING TO EQUALLY SPAN 1ST AND 2ND FLOOR BOX BEAM of Health Services, Town Building Departments, DEC, FEMA, etC. (d) CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) 3 SHEATHING TO EQUALLY SPAN 2ND FLOOR AND ATTIC TOP PLATES Verify all conditions, codes, and requirements with such agencies prior to JAMES'� J DEERKOSK1, P SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT. ( ) (e) SEE SECTION R402.2 FOR MINIMUM CEMENT CONTENT. (4) SHEATHING TO BE NAILED TO TOP PLATE construction. © D•A•K ASSOCIATES, LLC D o A o K ASSOCIATES LLC EXISTING HOUSE EXISTING HOUSE residential & commercial design s engineering s consulting 506 Maim Street phone: 1631)767-6071 o� o� Westhampton Beach,New York 11978 fax: [631)466-3354 CD H2x ������H �H ����� Deerkoski,Arm&Kehl Associates,LLC oformerly East End Design Associates,LLC m 2x8 ACQ irder ACQ Girder 2x8 ACQ Girder OWNERSHIP & USE OF DOCUMENTS: 3'-11' 2 o 0 0 0 o(I Theise drawings and specifications including the idleas, design and arrangements represented II therein, are the property of D.A.K. ASSOCIATES, N LLC. No part thereof shall be copied, disclosed co of co to others or used in connection with any work Q o Q Q Q or project other than for which they have been A 6x6 ACQ Post Wrapped 6x6 ACQ Post Wrapped A A I �I II I II I A prepared without written consent. 1 with Azek with Azek 1 I (I II (I I II I 1 1 66 Simpson Post Anchor 66 Simpson Post Anchor LI I���IJ_J1_J[_ �WLJL��WLJBolted to Pier with Y"x 12" Bolted to Pier with Y"x 12" LEI 2x8 ACQ der 2x8 ACQ Girder 2x8 ACQ Anchor Bolts Anchor Bolts �I II II I� II rile Provide 12" Sona Tube Conc, Pier Provide 12" Sona Tube Conc. Pier U �I II II U(J IJ IJ (Min. 3'-0" Below Final Grade) (Min. 3' 0" Below Final Grade) I I I I I I I I I -102" -z" -102' I' �I' I }i1' J1' !1I JII' Jl JZI' J2 J� II1'-944' -4" -4" '-4' '-4" -4" -4" '-4" '-4' '-4" -4' '-4" '-4" '-4' -4' '-4' '-4' '-4' '-4" -94" 7'-72' FOUNDATION PLAN- PATIO REFLECTIVE CEILING PLAN_ Scale: 1/4" = 1'-0" Scale: 1/4" = 1'-0" WORK NOTES: 2x2 ACQ Trellis - 16"oc. EXISTING HOUSE 2x8 ACQ Joists - 16"oc. Post at House is Anchored to 2x8 ACQ Girder 2x8 ACQ Girder 2x8 ACQ Girder� -U House �F'�WIIACQ IlTr,llis J H16oc. 6x6 ACQ Post Wrapped with Azek 2x2 .ACQ Trellis 16"oc. II 1="?y21CQ Trellis 16"oc. 6x6 Simpson Post Anchor Bolted to Pier with Y"x 12" Anchor Bolts 2x2 ACQ krelrisll16"oc. PROJECT: Provide 12" Sona Tube Conc. Pier (Min. 3'-0" Below Final Grade) AS BUILT PATIO TRELLIS CEILING PLAN- SECTION A TO THE KENNY Scale: 1/4" = 1'-0" Scale: 1/4" = 1'-0" q0T RESIDENCE 635 STROHSON ROAD CUTCHOGUE, NEW YORK DRAWING TITLE: Pergola Plan SET: ISSUED FOR: DATE: SEAL: DATE: June 3rd, 2013 PROJECT NO: 965-2013 DRAWN BY: BDK OF NEB' \ CHECKED BY: DEFR� �r JJD SHEET NUMBER: NORTHERN ELEVATION Al 01 T, Lu ,q 072 f'OF- "), DOB NUMBER: OF JAMES J DEERKOSKI, 0 D•A-K ASSOCIATES, uc GENERAL NOTES: SAFETY NOTES: RESIDENTIAL RENOVATION & CONSTRUCTIONS i pfBF FF9 1 . GENERAL ALL WORK TO BE COMPLETED IN ACCORDANCE WITH THE TOWN OF SOUTHOLD, NEW YORK, BUILDING CODE, AND CONTRACTOR N 0 T E SGeneral Notes: REGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION. % ,;� Wood: 4 - - 1 . All studs to be SPF #2 or better, and all other structural wood to be Douglas Fir #2: or better. 2. FIRE SAFETY: A ALL BUILDING MATERIALS WHICH ARE STORED AT THE SITE OR ANY AREA OF THE BUILDING ARE TO BE STORED IN A D °A°K ASSOCIATES LLC 2. All structural wood shall be in accordance with the national design specifications for v� A.ood construction — latest edition. residential s. commercial design o engineering o consulting B. LOCKED AREA. GENERAL NOTES: 3. Nailing schedule shall be in accordance with the specified code. C. ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION 4. Pre—manufactured trusses, D. ALL FLAMMABLE MATERIALS TO BE KEPT TIGHTLY SEALED IN THEIR RESPECTIVE MANUFACTURER'S CONTAINERS. SUCH 506 Main Street phone: I631�767-6071 1 • ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE TOWN OF SOUTHOLD, SUFFOLK COUNTY, NEW YORK, BUILDING CODE, o. All trusses shall be "shaped" as shown on architectural cross sections. Westhampton Beach,New York 11978 fax: (631)466-3354 FIRE DEPARTMENT RULES AND REGULATION'S, UTILITY COMPANY REQUIREMENTS, AND THE BEST TRADE PRACTICES. b. Trusses shall bear a Boca number and shall be manufactured by a registered manufacturer. MATERIALS ARE TO BE KEPT AWAY FROM HEAT. E. ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN ADEQUATELY VENTILATED SPACE, E-Mail: CArm8888aaol.com 2. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF 5. Erect and brace trusses in accordance to truss plate institute recommendations. -Deerkoski,Arm&Kehl Associates,LLC o formerly East End Design Associates,LLC BUILDINGS, OBTAIN ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, F. ALL ELECTRICAL POWER TO BE SHUT OFF WHERE THERE ARE EXPOSED CONDUITS. AND PAY ALL FEES REQUIRED BY THE GOWERNING BODY OF THE TOWN OF SOUTHOLD, NEW YORK, AGENCIES 6. Plywood sheathing. G. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS. OWNERSHIP & USE OF DOCUMENTS: a. All plywood shall be in accordance with the American Plywood Association (APA\) specifications. These drawings and specifications including the 3. MINOR DETAILS NOT USUALLY SHOWN OR `.SPECIFIED, BUT REQUIRED FOR PROPER CONSTRUCITON OF ANY PART OF THE WORK b, Plywood sheathing shall be continuous over two or more spans with grain of fface plys across supports CONTRACTOR, AT ALL TIMES, TO ENSURE THERE IS NO NATURAL GAS LEAKAGE IN THE BUILDINGS, OR ANY FLAMMABLE ideas, design and arrangements represented SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS. corporation or equal. GAS TO BE USED DURING CONSTRUCTION. therein, are the property of D.A.K. ASSOCIATES, LLC. No part thereof shall be copied, disclosed 4. THE CONTRACTOR SHALL COORDINATE ALL WORK PROCEDURES WITH THE STIPULATIONS OF LOCAL AUTHORITIES, AND OWNER. 7. All sills shall be pressure preservative treated (.4 PSF retention) SYP #2 or better. 3. DUST CONTROL: to others or used in connection with any work or piroject other than for which they have been 5• THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED prepared without written consent. CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORING AND BRACING FOR ALL STRUCTURAL OR 8. Design values: A. DEBRIS, DIRT AND DUST TO BE KEPT TO A MINIMUM AND CONFINED TO THE IMMEDIATE CONSTRUCTION AREA, REMOVAL TASKS. THE CONTRACTOR THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY a. Framing Lumber: DF (north) No. 2 or better B. CONTRACTOR TO ISOLATE CONTRUCTION AREA FROM OCCUPIED BUILDING AREA BY MEANS OF TEMPORARY PARTITIONS OR OR DURING THE EXECUTION OF THE WORK_ E = 1,600,000 PSI Fv = 95 PSI C, HEAVY DROP CLOTHS, 6. THE CONTRACTOR SHALL LAY OUT HIS OWIN WORK, AND SHALL AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES: Fb — 825 PSI DEBRIS, DIRT, AN DUST TO BE CLEANED UP AND CLEARED FROM THE BUILDING SITE PERIODICALLY TO AVOID EXCESSIVE PLUMBING, ELECTRICALS, ETC. 9. Design values: ACCUMULATION. 7. PLUMBING WORK SHALL 13E PERFORMED B'Y PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN THROUGH a. Laminated Veneer Lumber (LVL): THE DEPARTMENT OF BUILDINGS ALL REQUIRED PERMITS, INSPECTIONS AND REQUIRED SIGN OFFS, E = 1,900,000 PSI 4. NOISE AFTER HOURS: Fv = 285 PSI 8, ELECTRICAL WORK SHALL BE PERFORMED :,BE PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN Fb = 2600 PSI A, CONSTRUCTION OPERATIONS WILL BE CONFINED TO NORMAL WORKING HOURS: 8AM TO 6PM, MONDAY TO FRIDAY, THROUGH THE BUREAU OF ELECTRICAL COINTROL ALL REQUIRED PERMITS, INSPECTIONS AND REQUIRED SIGN OFFS. B. EXCEPT LEGAL HOLIDAYS. 9. THE CONTRACTOR SHALL DO ALL CUTTING, PATCHING, REPAIRING AS REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. NOTE CONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM ALL AFFECTED PARTIES TO WORK OTHER THAN REGULAR HOURS. DRAWINGS, AND ALL OTHER WORK THAT M)AY BE REQUIRED TO COMPLETE THE JOB. DEERKOSKI, ARM & KEHL ASSOCIATES, LLC, AND THERE ASSOCIATED ENGINEER ARE NOT OVERSEEING THE CONSTRUCTION OF THIS BUILDING. THE USE OF THESE DRAWINGS BY ANY CONTRACTOR, SUBCONTRACTOR, BUILDER, TfRADESMAN OR WORKER SHALL 5 CONSTRUCTION OPERATIONS WILL NOT INVOLVE INTERRUPTION OF HEATING, WATER, OR ELECTRICAL SERVICES TO THE OWNER. 10. ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONCEALMENT AND SHALL BE PROPERLY CAPPED OR PLUGGED. INSTIGATE A HOLD HARMLESS AGREEMENT BETWEEN THE DRAWING USER AND DEERKOSKI, ARMI & KEHL ASSOCIATES, LLC. CONSTRUCTION WORK WILL BE CONFINED TO THE WORK ISSUED, AND WILL NOT CREATE DUST, DIRT, OR OTHER SUCH INCONVENIENCES TO THE OTHER NEIGHHBORS. 11 . ALL DIMENSIONS ARE ESTABLISHED FROM 'THE FINISH LEVEL OF THE FIRST FLOOR. VARIATIONS TO THE HEIGHT OF THE FINISH THE USER SHALL IN FACT AGREE TO HOLD DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. HARMILESS FOR ANY RESPONSIBILITY IN LEVEL OF THE FIRST FLOOR ARE TO BE REVIEWED FOR APPROVAL BY THE OWNER AND DAK ASSOCIATES, LLC. NO CONSTRUCTION REGARD TO CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES AND) FOR ANY SAFETY PRECAUTIONS AND 6 SPECIAL SAFETY NOTES WILL BE ALLOWED TO COMMENCE UNTIL THIS HEIGHT IS APPROVED. PROGRAMS IN CONNECTION WITH THE WORK AND FURTHER SHALL HOLD THE ARCHITECT HARMILESS FOR COSTS AND PROBLEMS ARISING FROM THE NEGLIGENCE OF THE CONTRACTOR, SUBCONTRACTOR, TRADESMAN, OR WORfKMAN. THE USE OF THESE DRAWINGS ALL CONTRACTORS AND THEIR REPRESENTATIVES WORKING ON THIS PROJECT SHALL AT ALL TIMES PRIOR AND DURING THE COURSE 12, THE CONTRACTOR IN COORDINATING THE WORK WILL REPORT ANY DISCREPANCIES TO THE ENGINEER'S ATTENTION FOR IMMEDIATE ALSO IMPLIES THAT DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. SHALL TAKE NO RESPONSIBILI.ITY FOR THE PLAN USER'S FAILURE TO OF THEIR ACTIVITY BE RESPONSIBLE FOR THE SAFETY OF THEIR EMPLOYEES AS WELL AS OTHERS AND IN THE CARE OF THE RESOLUTION. CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWING OR CONTRACT DOCUMENTS. PROPERTY. EACH AS REPRESENTATIVES OF THEIR EMPLOYEES SHALL ASCERTAIN THAT THE CONDITIONS UNDER WHICH THEY WILL BE REQUIRED TO ACCOMPLISH THEIR WORK ARE SAFE WITHIN GOOD SAFETY PRACTICES AND MEET ALL CONCERNED REGULATIONS OF 13. THE CONTRACTOR WILL COORDINATE THE ROUTING AND PLACEMENT OF ALL UTILITY LINES WITH THIS AND RELATED SITE WORK, AND THE OCCUPATIONAL SAFETY AND HAZARD ACT OR OTHER GOVERNING REGULATIONS. THE BEGINNING OF WORK BY A CONTRACTOR WORK rvOTES: HE WILL BE RESPONSIBLE FOR ALL DISCOINNECTIONS, RECONNECTIONS, AND STARTUPS. DOCUMENT NOTES SHALL INDICATE SATISFACTION CONCERNING SAFETY AND FULL RESPONSIBILITY FOR ACCIDENTS OR DAMAGE. IF UNSATISFIED, THE CONTRACTOR SHALL INDICATE WHATEVER ACTION NECESSARY, OR RENDER SAFETY CONDITIONS FOR LIFE AND PROPERTY AS ARE 14. THE CONTRACTOR WILL COORDINATE THE ROUTING AND PLACEMENT OF ELECTRICAL, PLUMBING, AND HVAC EQUIPMENT WITH THESE CONSTRUCTION DOCUMENTS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY OTHERS. ALSO, THE CLIENT RELATED TO HIS ACTIVITY, IF THE WORK OF OTHER PARTIES OUTSIDE OF THE ORGANIZATION IS UPON INSPECTION FOUND AT ANY AGREES, TO THE FULLEST EXTENT OF THE LAW, TO INDEMNIFY AND HOLD DEERKOSKI, ARM &', KEHL ASSOCIATES, LLC. HARMLESS TIME TO BE UNSAFE, HE SHOULD STOP WORK IMMEDIATELY AND NOTIFY THE GENERAL CONTRACTOR, DAK ASSOCIATES, LLC OR ARCHITECTURAL FEATURE`. AND STRUCTURE. ANY CONFLICTS WILL BE BROUGHT TO THE ENGINEER'S ATTENTION FOR IMMEDIATE FROM ANY CLAIM, LIABILITY OR COST INCLUDING REASONABLE ATTORNEY'S FEES AND COSTS CJF DEFENSE, FOR THE INJURY OR OWNER. THE BEGINNING OF WORK SHALL INDICATE SATISFACTION WITH CONDITIONS AND ACCEPTANCE OF THESE REQUIREMENTS. RESOLUTION. ECONOMIC LOSS ARISING OR ALLEGEDLY ARISING OUT OF THE PROFESSIONAL SERVICES PROVIDED UNDER THIS AGREEMENT. 7 PROVIDE SINGLE AD MULTIPLE—STATION SMOKE ALARMS AS WELL AS CARBON MONOXIDE DETECTORS SINGLE AND MULTIPLE—STATION IN ACCORDANCE WITH STATE, FEDERAL, AND LOCAL CODES. CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND WIND SEISMIC SUBJECT TO DAMAGE FROM WINTER ICE SHIELD WORK PERFORMED SNOW DESIGN FROST LINE DESIGN UNDERLAY— FLOOD WIND EXPOSURE LOAD SPEED (mph) CATEGORY WIEATHERING DEPTH TERMITE DECAY TEMP. MENT REQUIRED HAZARDS CATEGORY ROOF DRAINAGE CALCULATIONS: 20 Ibs/sqft 120 (mph) C SEVERE 3'—p" MODERATE TO HEAVY SLIGHT TO MODERATE 11 degrees YES 1984/1998 C DESIGN CRITERIA CONSTRUCTED A PERGOLA OIN REAR YARD OF RESIDENCE PRESCRIPTIVE DESIGN MINIMUM UNIFORM DISTRIBUTED LIVE LOADS LOCATED AT 635 S TR O H S O N ROAD C U TC H O G U E NEW YORK ROOF AREA IS NEGLIGIBLE AS THE CONSTRUCTION IS (in pounds per square foot) ' AN OPEN ROOF WHICH COLLECTS NO RAIN WATER. USES(s) AND OCCUPANCY CLASSIFICATICON(s) USE LIVE LOAD DEAD LOAD PROPERTY IS FLAT AND ANY RUN-OFF WILL BE COLLECTED USE OCCUPANCY EXTERIOR BALCONIES 60 10 ON SITE. RESIDENTIAL R-3 DECKS (f) 40 10 TYPE OF CONSTRUCTION (CHAPTER 6) PASSENGER VEHICLE GARAGES (a) 50 (a) 10 TYPE GROUP ATTICS WITHOUT STORAGE (b,e) 10 10 V B ATTICS WITH STORAGE (b,e) 20 10 PROJECT: HEIGHT AND FIRE AREA ROOMS OTHER THAN SLEEPING ROOMS 40 10 HEIGHT FIRE ARIEA SLEEPING ROOMS 30 10 AS BUILT HEIGHT, BUILDING. THE VERTICAL DISTANCE STAIRS 40 (c) 10 TO THE FROM GRADE PLANE TO UNLIMITED )AREA THE AVERAGE HEIGHT 3 STOR'Y OF THE HIGHEST ROOF AS PER TABLE 503 GUARDRAIL AND HANDRAILS (d) 200 (c) 10 KENNY SURFACE = N/A AS PER SECTION 502 OF" ROOF 30 10 RESIDENCE THE BUILDING CODE OF NEW YORK STATE. o) ELEVATED GARAGE LE TOTAL HEIGHT FROM RIDGE TO GRADE N/A POUNDLOADAPPLIED OVER SAA20 S QUAREB OF CHAREAPORTING A 2,000— 635 STROHSON ROAD b) NO STORAGE WITH ROOF SLOPE NOT OVER 3 UNITS IN 12 UNITS. CUTCHOGUE, NEW YORK LUMI3ER SPECIES AND GRADE c) INDIVIDUAL STAIR TREADS SHALL BE DESIGNED FOR THE UNIFORMLY DISTRIBUTED LIVE LOAD OR A 300—POUND CONCENTRATED LOAD ACTING OVER AN AREA OF 4 SQUARE INCHES, WHICHEVER PRODUCES THE GREATER DRAWING TITLE: ALL HOUSE FRAMING MATERIAL DOU(GLAS FIR — LARCH #2 AND BETTER STRESSES. ALL EXT. DECK FRAMING MATERIAL CCA NC PINE #2 AND BETTER d) A SINGLE CONCENTRATION WITH WOOD TRUSSES SHALL BE DESIGNED IN GENERAL NOTES ACCORDANCE WITH SECTION R802.10.1. e) SEE SECTION R502.2.1 FOR DECKS ATTACHED TO EXTERIOR WALLS TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE SET: ISSUED FOR: DATE: AREAS OF STRUCTURE MINIMUM SPECIFIED COMPRESSION STRENGTH (a) (fc) CRAWL SPACE IVA BASEMENT NATYPE OR LOCATION OF CONCRETE CONSTRUCTION WEATHERING POTENTIAL FIRST FLOOR NA SEVERE (b) SECOND FLOOR NA BASEMENT WALLS, FOUNDATIONS AND OTHER THIRD FLOOR NA CONCRETE NOT EXPOSED TO THE WEATHER 2,500 (c) BALCONY NA FIRE BLOCKING IS TO BE INSTALLED TO MEET OR EXCEED ALL REQUIREMENTS OF THE BUILDING CODE SEAL: DATE: LOFT NA OF NEW YORK STATE, AND THE AMERICAN FOREST & PAPER ASSOCIATION (AF & PA) WOOD FRAME June 3rd, 2013 ATTIC (HOUSE)(c) NA BASEMENT SLABS AND INTERIOR SLAB ON 2,500 (c) CONSTRUCTION MANUAL WFCM FOR ONE AND TWO FAMIILY DWELLINGS, 2001 SBC HIGH WIND EDITION. PROJECT NO: GRADE, EXCEPT GARAGE FLOOR SLABS ( ) © COPYRIGHT 2011 D.A.K ASSOCIATES, LLC. ATTIC (HOUSE)(b) IJA 965-2013 GARAGE NA NO SUBSTITUTIONS _ DRAWN BY: NOTE: ALL ROOMS MEET OR EXCEED THE NYS. STANDARDS ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED ATTIC (GARAGE)(a) NA BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS AND All Framing Hardware Shown On these Plans, nr NF� BDK FOR THE NATURAL LIGHT AND VENTILATION REQUIREMENTS.. UNDER FEDERAL COPYRIGHT LAW. BONUS ROOM IJA OTHER VERTICAL CONCRETE WORK EXPOSED TO THE WEATHER 3,000 (d) Unless Otherwise Indicated, Is Simpson Strong— P �. DBE,,y� CHECKED BY: PERGOLA 313 sq. ft. Tie. No Substitutions are Approved or Authorized. PLANS MAY NOT BE REPRODUCED WITHOUT 5 ��-h�o ALL SIMPSON HANGERS HAVE BEEN CERTIFIED BY AN ENGINEER TO HAVE A CAPACITY PP WRITTEN AUTHORIZATION. a1 s JJD SOUTHERN DECK NA A,;. PORCHES, CARPORTS AND STEPS EXPOSED TO EQUAL TO OR GREATER THAN THE REQUIRED AMOUNT CALCULATED FOR EACH CASE. ALL PLANS AND DESIGNS ARE THE SOLE PROPERTY OF + ;�?;, ,, ' SHEET NUMBER: WESTERN DECK NA Due to the Relationships Of Framing Hardware THE WEATHER, AND GARAGE FLOOR SLABS 3,500 (d) P g w D.A.K. ASSOCIATES, LLC. �`"'-.� FRONT PORCH NA SHEATHING NOTES: to the other Components of the Structure, any �j'._L �sJ`� THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE SIDE PORCH NA ALL SHEATHING TO BE NAILED IN ACCORDANCE WITH THE NAILING SCHEDULE OF THE AMERICAN FOREST Framing Hardware Substitutions will RenderG1 POOL HOUSE CABANA NA & PAPER ASSOCIATION (AF & PA) WOOD FRAME CONSTRUiCTION MANUAL (WFCM) FOR ONE AND TWO These Plans Null and Void, and will Result in the PLANS IS LICENSED EXCLUSIVELY TO THE BUYER. 07 2 UNCOVERED ENTRANCES NA FOR SI: 1 POUND PER SQUARE INCH + 6.895 kpa FAMILY DWELLINGS, 2001 SBC HIGH WIND EDITION. Installer Contractor Assuming Responsibility for (a) AT 28 DAYS PSI � 9 P Y Acceptance of these drawings does not authorize the right to build without (a) WITHOUT STORAGE (b) SEE TABLE R301.2(1) FOR WEATHERING POTENTIAL the Design and Performance Of the Entire System. the authorization of local governing agencies, such as Suffolk County Dept. DOB NUMBER: OF (c) CONCRETE IN THESE LOCATIONS THAT MAY BE SUBJECT TO FREEZING AND THAWING DURING (1) SHEATHING TO BE NAILED TO CCA SILL (b) WITH STORAGE CONSTRUCTION SHALL BE AIR—ENTRAINED CONCRETE IN ACCORDANCE WITH FOOTNOTE (d) (2) SHEATHING TO EQUALLY SPAN 1ST AND 2ND FLOOR BOX BEAM of Health Services, Town Building Departments, DEC, FEMA, etc. (d) CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME OF CONCRETE) 3 SHEATHING TO EQUALLY SPAN 2ND FLOOR AND ATTIC TOP PLATES Verify all conditions, codes, and requirements with such agencies prior to JAMES J DEERKOSKI, PE SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT. ( ) (e) SEE SECTION R402.2 FOR MINIMUM CEMENT CONTENT. (4) SHEATHING TO BE NAILED TO TOP PLATE construction. © D•A•K ASSOCIATES, uc f - - - �� �� , D a A a K ASSOCIATES LLc residential & commercial design .engineering•consulting EXISTING HOUSE EXISTING HOUSE 506 Main Street phone: (631)767-6071 ~o� CD Westhampton o� Westhampton Beach,New York 11978 fox: �631)466 3354 H""I "ACQ I IE-Mail: CArm8888@aol.com r Hrd "J"NM�"��� Deerkoslki,Arm&Kehl Associates,LLC oformerly East End Design Associates,LLC I I - - -ACQ Girder 2z8 ACQ Girder _- OWNER;SHIP & USE OF DOCUMENTS: 11'-112 13 3'-11" I o '3 I of The 9 se drawings and specifications including the n II I II I II I) II ideas, design and arrangements represented therein, are the N � e property of D.A.K. ASSOCIATES, Co II I a II II al I o II Q QI00 LLC.. No part thereof shall be copied, disclosed 00 v I to (others or used in connection with any work or project other than for which they have been A 6x6 ACQ Post Wrapped 6z6 ACQ Post Wrapped A A I °� °�I I A Iprepared without written consent. U I with Azek with Azek 1 0 1 I 1 C L_ 1 U "1 IL 6z6 Simpson Post Anchor 6x6 Simpson Post Anchor LI I�[ACQ]LtjLLj[=�L2jx8 [AC0]6dLL]L2x8 LACO]U 1 Bolted to Pier with Y"x 12" Bolted to Pier with Y"x 12" I�1I 2x8 Anchor Bolts O Anchor Bolts O Pr de in -9 •`�I 1,-4"I 1'-4"I 1'-4"I I'-4".KI '-4"I I'-4'I I'-4"J I Z'-4"I i'-4`I 1'-4"J I 2'-4"J I�'-4'I I'-4`I 1'-4'I I I I - �ra', Provide 12" Sona Tube Conc. Pier 12" Sono Tube Conc. Pier (Min. 3 0 Below Final Grade) M . 3 0 Below Final Grade) 8 -10N _2. -10 "2 2 94'4 . 10 7'-72" FOUNDATION PLAN- PATIO REFLECTIVE CEILING PLAN- Scale: 1/4" = 1'-0" Scale: 1/4" = 1'-0" WORK (NOTES: EXISTING HOUSE 2x2 ACQ Trellis - 16"oc. 2x8 ACQ Joists - 16"oc. Post at House is Anchored to 2x8 ACQ Girder 2x8 ACQ Girder 2x8 ACQ Girder House `t9H��H�1711 [111 2x211ACQ Trellis 16"oc. 66 ACQ Post Wrapped with Azek 2x2 JACQ JTrellis 16"oc.1� ET IF---IFIEL---1FJ J 11 1� 1� 11 J� i i 2x2 ACQ I Trellis 16"oc. 1 6x6 Simpson Post Anchor Bolted to Pier with Y"x 12" "" "" Anchor Bolts L L IJ 2z2 L LTreIrjsLl6"oc. PROJECT: Provide 12" Sono Tube Conc. Pier (Min. 3'-0" Below Final Grade) AS BUILT PATIO TRELLIS CEILING PLAN- SECTION (--A TO THE 1 Scale: 1/4" = 1'-0" Scale: 1/4" = 1'-0" 1 A I KEY RESIDENCE 635 STROHSON ROAD CUTCHOGUE, NEW YORK DRAWING TITLE: Pergola Plan SET: ISSUED FOR: DATE: SEAL: DATE: June 3rd, 2013 PROJECT NO: 965-2013 DRAWN BY: BDK o� Y CHECKED BY: n ro T JJ D f,,.(.,:,,,�1r SHEET NUMBER: NORTHERN ELEVATIONf y , ,U w s Lu (JA Al 01 S 10`��� L DOB NUMBER: OF JAMES J DEERKOSKI, PE © D•A•K ASSOCIATES, LLC GENERAL NOTES: SAFETY NOTES: RESIDENTIAL RENOVATION & CONSTRUCTION ���' JCI / 1 . GENERAL: ALL WORK TO BE COMPLETED IN ACCORDANCE WITH THE TOWN OF SOUTHOLD, NEW YORK, BUILDING CODE, AND %; General Notes: ,-,,x - - CONTRACTOR N 0 T E SREGULATIONS OF ALL OTHER AGENCIES HAVING JURISDICTION. / J �„ 'Mt- 1I Wood: - . All studs to be SPF #2 or better, and all other structural wood to be Douglas Fir #12 or better. 2. FIRE SAFETY: 2. All structural wood shall be in accordance with the national design specifications for wood construction - latest edition. A. ALL BUILDING MATERIALS WHICH ARE STORED AT THE SITE OR ANY AREA OF THE BUILDING ARE TO BE STORED IN A D °A°K ASSOCIATES LLC 9 P residential & commercial design •engineering •consulting B. LOCKED AREA. GENERAL NOTES: 3. Nailing schedule shall be in accordance with the specified code. C. ALL MATERIALS TO BE STORED IN AN ORDERLY FASHION 4. Pre—manufactured trusses. SO6McinStreet phone: 16311767-6071 D. ALL FLAMMABLE MATERIALS TO BE KEPT TIGHTLY SEALED IN THEIR RESPECTIVE MANUFACTURER'S CONTAINERS, SUCH 1 • ALL WORK SHALL CONFORM TO THE REQiUIREMENTS OF THE TOWN OF SOUTHOLD, SUFFOLK COUNTY, NEW YORK, BUILDING CODE, a, All trusses shall be "shaped" as shown on architectural cross sections. WesthalmpfonBeach,New York 11978 fax: (631 J 466-3354 FIRE DEPARTMENT RULES AND REGULATIONS, UTILITY COMPANY REQUIREMENTS, AND THE BEST TRADE PRACTICES. b. Trusses shall bear a boca number and shall be manufactured by a registeretid manufacturer. MATERIALS ARE TO BE KEPT AWAY FROM HEAT, 2. BEFORE COMMENCING WORK, THE CONTRACTOR SHALL FILE ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF E. ALL FLAMMABLE MATERIALS TO BE USED AND STORED IN ADEQUATELY VENTILATED SPACE. EMail: gnAss88�aol.com 5. Erect and brace trusses in accordance to truss plate institute recommendations. oeerk_o_Ski,a,rms.Kenin55acia,es,��corarmerlYeaStEnaoeSignSso�iares,uc__ BUILDINGS, OBTAIN ALL REQUIRED INSURANCE CERTIFICATES WITH THE DEPARTMENT OF BUILDINGS, OBTAIN ALL REQUIRED PERMITS, F. ALL ELECTRICAL POWER TO BE SHUT OFF WHERE THERE ARE EXPOSED CONDUITS. AND PAY ALL FEES REQUIRED BY THE GOVERNING BODY OF THE TOWN OF SOUTHOLD, NEW YORK, AGENCIES 6. Plywood sheathing. G. ALL ELECTRICAL POWER IN THE CONSTRUCTION AREA TO BE SHUT OFF AFTER WORKING HOURS. OWNEIRSHIP & USE OF DOCUMENTS; a. All plywood shall be in accordance with the American Plywood Association (AP CONTRACTOR AT ALL TIMES A) specifications. Th(ese drawings and specifications including the 3. MINOR DETAILS NOT USUALLY SHOWN OR SPECIFIED, BUT REQUIRED FOR PROPER CONSTRUCITON OF ANY PART OF THE WORK b. Plywood sheathing shall be continuous over two or more spans with grain of face plys across supports , , TO ENSURE THERE IS NO NATURAL GAS LEAKAGE IN THE BUILDINGS, OR ANY FLAMMABLE ideas, design and arrangements represented SHALL BE INCLUDED AS IF THEY WERE INDICATED IN THE DRAWINGS. corporation or equal. GAS TO BE USED DURING CONSTRUCTION. therein, are the property of D.A.K. ASSOCIATES, 4. THE CONTRACTOR SHALT_ COORDINATE ALL. WORK PROCEDURES WITH THE STIPULATIONS OF LOCAL AUTHORITIES, AND OWNER. LLC. No part thereof shall be copied, disclosed 7. All sills shall be pressure preservative treated (,4 PSF retention) SYP #2 or better, 3. DUST CONTROL: to others or used in connection with any work or project other than for which they have been 5. THE CONTRACTOR SHALT_ BE RESPONSIBLE FOR THE PROTECTION OF ALL CONDITIONS AND MATERIALS WITHIN THE PROPOSED CONSTRUCTION AREA. THE CONTRACTOR SHALL DESIGN AND INSTALL ADEQUATE SHORING AND BRACING FOR ALL STRUCTURAL OR 8. Design values: A. DEBRIS, DIRT AND DUST TO BE KEPT TO A MINIMUM AND CONFINED TO THE IMMEDIATE CONSTRUCTION AREA. prepared without written consent. REMOVAL TASKS. THE CONTRACTOR THE CONTRACTOR SHALL HAVE SOLE RESPONSIBILITY FOR ANY DAMAGE OR INJURIES CAUSED BY a. Framing Lumber: DF (north) No. 2 or better B. CONTRACTOR TO ISOLATE CONTRUCTION AREA FROM OCCUPIED BUILDING AREA BY MEANS OF TEMPORARY PARTITIONS OR OR DURING THE EXECUTION OF THE WORK. E = 1 ,600,000 PSI Fv = 95 PSI C. HEAVY DROP CLOTHS. 6. THE CONTRACTOR SHALT_ LAY OUT HIS OWN WORK, AND SHALL AND SHALL PROVIDE ALL DIMENSIONS REQUIRED FOR OTHER TRADES: Fb - 825 PSI DEBRIS, DIRT, AN DUST TO BE CLEANED UP AND CLEARED FROM THE BUILDING SITE PERIODICALLY TO AVOID EXCESSIVE PLUMBING, ELECTRICALS, ETC. 9. Design values: ACCUMULATION. 7. PLUMBING WORK SHALL BE PERFORMED iBY PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN THROUGH a. Laminated Veneer Lumber (LVL): THE DEPARTMENT OF BUILDINGS ALL REQUIRED PERMITS, INSPECTIONS AND REQUIRED SIGN OFFS. E = 1,900,000 PSI 4. NOISE AFTER HOURS: Fv = 285 PSI 8. ELECTRICAL WORK SHALL BE PERFORMED, BE PERSONS LICENSED IN THEIR TRADES, WHO SHALL ARRANGE FOR AND OBTAIN Fb = 2600 PSI A. CONSTRUCTION OPERATIONS WILL BE CONFINED TO NORMAL WORKING HOURS: 8AM TO 6PM, MONDAY TO FRIDAY, THROUGH THE BUREAU OF ELECTRICAL CONTROL ALL REQUIRED PERMITS, INSPECTIONS AND REQUIRED SIGN OFFS. B. EXCEPT LEGAL HOLIDAYS. DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. NOTE CONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM ALL AFFECTED PARTIES TO WORK OTHER THAN REGULAR HOURS. 9. THE CONTRACTOR SHALT_ DO ALL CUTTING, PATCHING, REPARING AS REQUIRED TO PERFORM ALL OF THE WORK INDICATED ON THE DEERKOSKI, ARM & KEHL ASSOCIATES, LLC, AND THERE ASSOCIATED ENGINEER ARE NOT OVERSEEING THE CONSTRUCTION OF THIS DRAWINGS, AND ALL OTHER WORK THAT WAY BE REQUIRED TO COMPLETE THE JOB. BUILDING. THE USE OF THESE DRAWINGS BY ANY CONTRACTOR, SUBCONTRACTOR, BUILDER, TRADESMAN OR WORKER SHALL 5 CONSTRUCTION OPERATIONS WILL NOT INVOLVE INTERRUPTION OF HEATING, WATER, OR ELECTRICAL SERVICES TO THE OWNER. 10. ALL PIPING AND WIRING SHALL BE REMOVED TO A POINT OF CONCEALMENT AND SHALL BE PROPERLY CAPPED OR PLUGGED, INSTIGATE A HOLD HARMLESS AGREEMENT BETWEEN THE DRAWING USER AND DEERKOSKI, ARI'M & KEHL ASSOCIATES, LLC. CONSTRUCTION WORK WILL BE CONFINED TO THE WORK ISSUED, AND WILL NOT CREATE DUST, DIRT, OR OTHER SUCH 1 1 . ALL DIMENSIONS ARE ESTABLISHED FROMI THE FINISH LEVEL OF THE FIRST FLOOR. VARIATIONS TO THE HEIGHT OF THE FINISH THE USER SHALL IN FACT AGREE TO HOLD DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. HARMLESS FOR ANY RESPONSIBILITY IN INCONVENIENCES TO THE OTHER NEIGHHBORS. LEVEL OF THE FIRST FLOOR ARE TO BE REVIEWED FOR APPROVAL BY THE OWNER AND DAK ASSOCIATES, LLC. NO CONSTRUCTION REGARD TO CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES ANJD FOR ANY SAFETY PRECAUTIONS AND WILL BE ALLOWED TO COMMENCE UNTIL -THIS HEIGHT IS APPROVED. PROGRAMS IN CONNECTION WITH THE WORK AND FURTHER SHALL HOLD THE ARCHITECT HARiMLESS FOR COSTS AND PROBLEMS 6 SPECIAL SAFETY NOTES ARISING FROM THE NEGLIGENCE OF THE CONTRACTOR, SUBCONTRACTOR, TRADESMAN, OR WORKMAN. THE USE OF THESE DRAWINGS ALL CONTRACTORS AND THEIR REPRESENTATIVES WORKING ON THIS PROJECT SHALL AT ALL TIMES PRIOR AND DURING THE COURSE 12. THE CONTRACTOR IN COORDINATING THE WORK WILL REPORT ANY DISCREPANCIES TO THE ENGINEER'S ATTENTION FOR IMMEDIATE ALSO IMPLIES THAT DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. SHALL TAKE NO RESPONSIBIILITY FOR THE PLAN USER'S FAILURE TO OF THEIR ACTIVITY BE RESPONSIBLE FOR THE SAFETY OF THEIR EMPLOYEES AS WELL AS OTHERS AND IN THE CARE OF THE RESOLUTION. CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWING OR CONTRACT DOCUMENTS. PROPERTY. EACH AS REPRESENTATIVES OF THEIR EMPLOYEES SHALL ASCERTAIN THAT THE CONDITIONS UNDER WHICH THEY WILL BE REQUIRED TO ACCOMPLISH THEIR WORK ARE SAFE WITHIN GOOD SAFETY PRACTICES AND MEET ALL CONCERNED REGULATIONS OF 13. THE CONTRACTOR WILL COORDINATE THE ROUTING AND PLACEMENT OF ALL UTILITY LINES WITH THIS AND RELATED SITE WORK, AND THE OCCUPATIONAL SAFETY AND HAZARD ACT OR OTHER GOVERNING REGULATIONS. THE BEGINNING OF WORK BY A CONTRACTOR WORK NOTES: HE WILL BE RESPONSIBLE FOR ALL DISCONNECTIONS, RECONNECTIONS, AND STARTUPS. DOCUMENT NOTES SHALL INDICATE SATISFACTION CONCERNING SAFETY AND FULL RESPONSIBILITY FOR ACCIDENTS OR DAMAGE. IF UNSATISFIED, THE THESE CONSTRUCTION DOCUMENTS HAVE BEEN PREPARED BASED ON INFORMATION PROVIDED BY OTHERS. ALSO, THE CLIENT CONTRACTOR SHALL INDICATE WHATEVER ACTION NECESSARY, OR RENDER SAFETY CONDITIONS FOR LIFE AND PROPERTY AS ARE 14. THE CONTRACTOR WILL COORDINATE THE ROUTING AND PLACEMENT OF ELECTRICAL, PLUMBING, AND HVAC EQUIPMENT WITH RELATED TO HIS ACTIVITY, IF THE WORK OF OTHER PARTIES OUTSIDE OF THE ORGANIZATION IS UPON INSPECTION FOUND AT ANY AGREES, TO THE FULLEST EXTENT OF THE LAW, TO INDEMNIFY AND HOLD DEERKOSKI, ARM & KEHL ASSOCIATES, LLC. HARMLESS TIME TO BE UNSAFE, HE SHOULD STOP WORK IMMEDIATELY AND NOTIFY THE GENERAL CONTRACTOR, DAK ASSOCIATES, LLC, OR ARCHITECTURAL FEATURES AND STRUCTURE. ANY CONFLICTS WILL BE BROUGHT TO THE ENGINEER'S ATTENTION FOR IMMEDIATE FROM ANY CLAIM, LIABILITY OR COST INCLUDING REASONABLE ATTORNEY'S FEES AND COSTS OF DEFENSE, FOR THE INJURY OR OWNER. THE BEGINNING OF WORK SHALL INDICATE SATISFACTION WITH CONDITIONS AND ACCEPTANCE OF THESE REQUIREMENTS. RESOLUTION. ECONOMIC LOSS ARISING OR ALLEGEDLY ARISING OUT OF THE PROFESSIONAL SERVICES PRONVIDED UNDER THIS AGREEMENT. 7 PROVIDE SINGLE AD MULTIPLE-STATION SMOKE ALARMS AS WELL AS CARBON MONOXIDE DETECTORS SINGLE AND MULTIPLE-STATION IN ACCORDANCE WITH STATE, FEDERAL, AND LOCAL CODES. CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND WIND SEISMIC SUBJECT TO DAMAGE FROM WINTER I ICE SHIELD WORK P EE_R F O R M E D SNOW DESIGN FROST LINE DESIGN UNDERLAY— FLOOD WIND EXPOSURE LOAD SPEED nn h CATEGORY WEATHERING DEPTH TERMITE DECAY TEMP. MENT REQUIRED HAZARDS CATEGORY ROOF DRAINAGE CALCULATIONS: 20 Ibs/sqft 120 (mph) C SEVERE 3'-0" MODERATE TO HEAVY SLIGHT TO MODERATE 11 degrees YES 1984/1998 C -: DESIGN CRITERIA CONSTRUCTED A PERGOLA ON REAR YARD OF RESIDENCE PRESCRIPTIVE DESIGN MINIMUM UNIFORM DISTRIBUTED LIVE LOADS LOCATED A T 635 S TR O H S O N ROAD , C U TC H O G U E NEW YORK ROOF AREA IS NEGLIGIBLE AS THE CONSTRUCTION IS (ir pounds per square foot) AN OPEN ROOF WHICH COLLECTS NO RAIN WATER. USES(s) AND OCCUPANCY CLASSIFICAITION(s) USE LIVE LOAD DEAD LOAD - PROPERTY IS FLAT AND ANY RUN—OFF WILL BE COLLECTED USE OCCUPANCY EXTERIOR BALCONIES 60 10 ON SITE. RESIDENTIAL R—.3 DECKS (f) 40 10 TYPE OF CONSTRUCTION (CHAPTEIR 6) PASSENGER VEHICLE GARAGES (a) 50 (a) 10 TYPE GROUP ATTICS WITHOUT STORAGE (b,e) 10 10 V B ATTICS WITH STORAGE (b,e) 20 10 PROJECT: HEIGHT AND FIRE AREA ROOMS OTHER THAN SLEEPING ROOMS 40 10 HEIGHT FIRE AREA SLEEPING ROOMS 30 10 AS BUILT TO THE HEIGHT, BUIL IN . THE VERTICAL DISTANCE STAIRS FROM GRADE PLANE TO 40 (c) 10 UNLIMITED) AREA THE AVERAGE HEIGHT 3 STO)RY GUARDRAIL AND HANDRAILS (d) 200 (c) 10 KENNY OF THE HIGHEST ROOF AS PER TAEBLE 503 SURFACE = N/A AS PER SECTION 502 OF ROOF 30 10 RESIDENCE THE BUILDING CODE OF NEW YORK STATE. o) TOTAL HEIGHT FROM RIDGE TO GRADE N/A POUND LOADGARAGE OADAPPLIED OVER SAA20 S QUARELL BE B NCHLE OFAREAPORTING A 2,000— 635 STROHSON ROAD b) NO STORAGE WITH ROOF SLOPE NOT OVER 3 UNITS IN 12 UNITS. CUTCHOGUE, NEW YORK LUMBER SPECIES AND GRADE c) INDIVIDUAL STAIR TREADS SHALL BE DESIGNED FOR THE UNIFORMLY DISTRIBUTED LIVE LOAD OR A 300—POUND CONCENTRATED LOAD ACTING OVER AN AREA OF 4 SQUARE INCHES, WHICHEVER PRODUCES THE GREATER DRAWING TITLE: ALL HOUSE FRAMING MATERIAL DOIUGLAS FIR — LARCH #2 AND BETTER STRESSES, ALL EXT. DECK FRAMING MATERIAL CC;A NC PINE #2 AND BETTER d) A SINGLE CONCENTRATION WITH WOOD TRUSSES SHALL BE DESIGNED IN GENERAL NOTES ACCORDANCE WITH SECTION R802.10.1. e) SEE SECTION R502.2.1 FOR DECKS ATTACHED TO EXTERIOR WALLS TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE SET: ISSUED FOR: DATE: AREAS OF STRUCTURE MINIMUM SPECIFIED COMPRESSION STRENGTH (a) (fc) CRAWL SPACE NA TYPE OR LOCATION OF CONCRETE CONSTRUCTION BASEMENT NA WEATHERING POTENTIAL FIRST FLOOR NA SEVERE (b) SECOND FLOOR NA BASEMENT WALLS, FOUNDATIONS AND OTHER THIRD FLOOR NA CONCRETE NOT EXPOSED TO THE WEATHER 2,500 (c) BALCONY NA FIRE BLOCKING IS TO BE INSTALLED TO MEET OR EXCEED ALL REQUIREMENTS OF THE BUILDING CODE SEAL: DATE: LOFT NA June 3rd, 2013 OF NEW YORK STATE, AND THE AMERICAN FOREST & PAPER ASSOCIATION (AF & PA) WOOD FRAME ATTIC (HOUSE)(a) NA BASEMENT SLABS AND INTERIOR SLAB ON 50o c CONSTRUCTION MANUAL WFCM FOR ONE AND TWO FArv1^ILY DWELLINGS, 2001 SBC HIGH WIND EDITION. PROJECT NO: ATTIC HOUSEb NA GRADE, EXCEPT GARAGE FLOOR SLABS 2, ( ) ( ) © COPYRIGHT 2011 D.A.K ASSOCIATES, LLC. 965-2013 GARAGE NA NO SUBSTITUTIONS DRAWN BY: NOTE: ALL ROOMS MEET OR EXCEED THE NYS. STANDARIDS ALL FLOOR PLANS AND ELEVATIONS ARE PROTECTED ATTIC (GARAGE)(a) All Framing Hardware Shown on these Plans, NA ��OF NEII BASEMENT WALLS, FOUNDATION WALLS, EXTERIOR WALLS AND FOR THE NATURAL LIGHT AND VENTILATION REQUIREMENT`S. UNDER FEDERAL COPYRIGHT LAW. P BDK BONUS ROOM NA OTHER VERTICAL CONCRETE WORK EXPOSED TO THE WEATHER 3,000 (d) Unless Otherwise Indicated, Is Simpson Strong— c` �' DE h� �P CHECKED BY: PERGOLA 313 sq. ft. PLANS MAY NOT BE REPRODUCED WITHOUT �o Tie. No Substitutions are Approved or Authorized, s ALL SIMPSON HANGERS HAVE BEEN CERTIFIED BY AN ENiGINEER TO HAVE A CAPACITY WRITTEN AUTHORIZATION. 1 JJD SOUTHERN DECK NA �' EQUAL TO OR GREATER THAN THE REQUIRED AMOUNT CALCULATED FOR EACH CASE. ALL PLANS AND DESIGNS ARE THE SOLE PROPERTY OF -Y ` . W SHEET NUMBER: PORCHES, CARPORTS AND STEPS EXPOSED TO Due to the Relationships of Framing Hardware ;. M,''�' WESTERN DECK NA w THE WEATHER, AND GARAGE FLOOR SLABS 3,500 (d) D.A.K. ASSOCIATES, LLC. FRONT PORCH NA SHEATHING NOTES: to the other Components of the Structure, any ' " _, .�a . SIDE PORCH NA ALL SHEATHING TO BE NAILED IN ACCORDANCE WITH THE_ NAILING SCHEDULE OF THE AMERICAN FOREST g THE RIGHT TO BUILD ONLY ONE STRUCTURE FROM THESE �d ,?° 07 `�� ��' G 1 Framin Hardware Substitutions will Render �. . PLANS IS LICENSED EXCLUSIVELY TO THE BUYER. POOL HOUSE CABANA NA & PAPER ASSOCIATION (AF & PA) WOOD FRAME CONSTRIUCTION MANUAL (WFCM) FOR ONE AND TWO These Plans Null and Void, and will Result in the �'� r �'� FOR SI: 1 POUND PER SQUARE INCH + 6.895 k a t 5�1�� UNCOVERED ENTRANCES NA p FAMILY DWELLINGS, 2001 SBC HIGH WIND EDITION. Installer Contractor Assuming Responsibility for ^ ' (a) AT 28 DAYS PSI 9 P Y Acceptance of these drawings does not authorize the right to build without (a) WITHOUT STORAGE (b) SEE TABLE R301.2(1) FOR WEATHERING POTENTIAL the Design and Performance of the Entire System. the authorization of local governing agencies, such as Suffolk County Dept. (c) CONCRETE IN THESE LOCATIONS THAT MAY BE SUBJECT TO FREEZING AND THAWING DURING (1) SHEATHING TO BE NAILED TO CCA SILL DOB NUMBER; OF of Health Services, Town Building Departments, DEC, FEMA, etc. (b) WITH STORAGE CONSTRUCTION SHALL BE AIR—ENTRAINED CONCRETE IN ACCORDANCE WITH FOOTNOTE (d) (2) SHEATHING TO EQUALLY SPAN 1ST AND 2ND FLOOR BOX BEAM (d) CONCRETE SHALL BE AIR ENTRAINED. TOTAL AIR CONTENT (PERCENT BY VOLUME of CONCRETE) 3 SHEATHING TO EQUALLY SPAN 2ND FLOOR AND ATTIC; TOP PLATES Verify all conditions, codes, and requirements with such agencies prior to JAMES J DEERKOSKI, PE SHALL NOT BE LESS THAN 5 PERCENT OR MORE THAN 7 PERCENT. ( ) (e) SEE SECTION R402.2 FOR MINIMUM CEMENT CONTENT. (4) SHEATHING TO BE NAILED TO TOP PLATE construction. © D•A•K ASSOCIATES, uc D o A o K ASSOCIATES LLc residential & commercial design a engineering e consulting EXISTING HOUSE EXISTING HOUSE 506 Maiin Street phone: (631)767-6071 Westhampton lm ton Beach,New York 11978 fax: (631)466-3354 p CDo CD E-Mail: CArm8888@aol.com Deerko)ski,Arm&Kehl Associates,LLC o formerly East End Design Associates,LLC � IOOf�001�HN AHO MLL"H�21x8I�ACQ der 2z8 ACQ ACQ Girder OWNEfRSHIP & USE OF DOCUMENTS: 11'-112' 11'-112" o o II o I I II II o II ( o These drawings and specifications including the 23'-11" ( I I I II I II Ideas, design and arrangements represented therein, are the property of D.A.K. ASSOCIATES, co LLC. No part thereof shall be copied, disclosed 00 to others or used in connection with any work coi or project other than for which they have been A x I I II n prepared without written consent. (V N CV N N CV /-1 A 6x6 ACQ Post Wrapped 6x6 ACQ Post Wrapped with Azek with Azek I U1 I I I II I 1 0 1 Bolted Simpson Post Anchor 6x6 Simpson Post Anchor �U� ]LLJU� �[ACQ]LdL]LL2x8][ACQ]W � Bolted to Pier with%"x 12" Bolted to Pier with y"x 12" 2x8 ACQ 2x8 Anchor Bolts Anchor Bolts �t Provide 12" Sona Tube Conc. Pier Provide 12" Sono Tube Conc. Pier I U ll tl (Min. 3-0 Below Final Grade) (Min. 3'-0" Below Final Grade) I I I I I I I 8-102" —2" —102" '— iI'— Ii1'— 31 —944 7'-72" FOUNDATION PLAN_ PATIO REFLECTIVE CEILING PLAN_ Scale: 1/4" = 1'-0" Scale: 1/4" = 1'-0" WORK NOTES: 2x2 ACQ Trellis - 16"oc. EXISTING HOUSE 2x8 ACQ Joists - 16"oc. Post at House is Anchored to III] III I ff 2x8 ACQ Girder 2x8 ACQ Girder 2x8 ACQ Girder House ri HHF�:TH11 2,21JACQ Trellis 16"oc. 66 ACQ Post Wrapped with Azek 2z2 ACQ Trellis I 16"oc. 1� 1� �� 11 1� IF 1� FFT 2x2 ACQ Trellis 16"oc. 6x6 Simpson Post Anchor Bolted to Pier with Y"x 12" ""L Anchor Bolts L-1 Li L 1� F�l 2x2 ACQ LTreIIisJL1Coc]LJL,. PROJECT: Provide 12" Sono Tube Conc. Pier (Min. 3'-0" Below Final Grade) AS BUILT PATIO TRELLIS CEILING PLANKENNY TO THE SECTION A Scale: 1/4 = 1 —0„ Scale: 1/4" = 1'-0" 707 RESIDENCE 635 STROHSON ROAD CUTCHOGUE, NEW YORK DRAWING TITLE: Pergola Plan SET: ISSUED FOR: DATE: SEAL: DATE: June 3rd, 2013 PROJECT NO: 965-2013 F CiF NF_ti/ DRAWN BY: D` BOK O� CHECKED BY: '"'� ` JJD c-, n a cw SHEET NUMBER: NORTHERN ELEVATION �1a '�� �o A101 DOB NUMBER: OF JAMES J DEERKOSKI, PE 0 D-A-K ASSOCIATES, LLC