Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
38098-Z
Town of Southold Annex 9/21/2013 P.O.Box 1179 54375 Main Road o s Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 36519 Date: 9/21/2013 THIS CERTIFIES that the building GENERATOR Location of Property: 3065 CR 48, Mattituck, SCTM#: 473889 See/ lock/Lot: 141.-2-14.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 6/7/2013 pursuant to which Building Permit No. 38098 dated 6/13/2013 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: generator as applied for. The certificate is issued to Tyler,Michael&Tyler,Virginia (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 38098 8/19/13 PLUMBERS CERTIFICATION DATED Authorized Signature �gvFFnt_x TOWN OF SOUTHOLD BUILDING DEPARTMENT y. TOWN CLERK'S OFFICE �o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 38098 Date: 6/13/2013 Permission is hereby granted to: Tyler, Michael & Tyler, Virginia PO BOX 1253 Mattituck, NY 11952 To: Generator At premises located at: 3065 CR 48, Mattituck SCTM # 473889 Sec/Block/Lot# 141.-2-14.1 Pursuant to application dated 6/7/2013 and approved by the Building Inspector. To expire on 12/13/2014. Fees: ACCESSORY $100.00 CO -ACCESSORY BUILDING $50.00 ELECTRIC $85.00 Total: $235.00 Building Inspector 5A.e Form No.6 TOWN OF SOUTHOLD. BUILDING DEPARTMENT TOWN HALL 765-1802 APPLICATION.FOR CERTIFICATE OF OCCUPANCY This-application must be filled in by typewriter or ink and submitted to the Building Department with the following: Ar For new building or new use: 1. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2, Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form)'. 3.. Approval of electrical installation from Board of Fire Underwriters. 4. •S;vorn statement from plumber certifying that the solder used in system contains less than 2l10 of I% lead. . 5. Commercial building,industrial building, multiple residences and similar buildings and installations,a certificate of Code Compliance-from architect or engineer responsible for.the building: .6. Submit Planning Board Approval of.completed site plan requirements- B. For existing buildings(prior to.April 9, 1957) non-conforming uses, or buildings and "pre-existing" land uses: 1. Accurate survey.of property showing all property lines,streets,building and.unusual natural or topographic features. 2. A properly completed application and consent to inspect signed-by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees 1. Certif cafe of Occupancy- New dwelling.$50.00, Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool $50.00, Accessory building$50.00, Additions to accessory building$50.00, Businesses $50.00_ 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy- $25 4. Updated Certificate of Occupancy - $50.00 5" Temporary Certificate of Occupancy - Residential $15"00,Commercial $15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: _ 3 O (215_ 9 19rn � e!� House No. Street Hamlet Owner or Owners of Property: m--r—C jy p r L 0L 0S R Gs0 7%. Suffolk County Tax Map No 1000, Section Block o2 Lot Subdivision Filed Map. Lot: Permit No. V Date of Permit. k -J 3 'J 3 Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final-Certificate: (check one) Fee Submitted: $ A�Iicantgnatur QS�FF01 Town Hall Annex 0�' CGy Telephone(631) 765-1802 54375 Main Road c Fax (631) 765-9502 v2 a P.O. Box 1179 0 • Southold, NY 11971-0959 ?'�jpl �.�0� roger.richert(aD-town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: Tyler Address: 3065 Rt 48 City: Mattituck St: NY Zip: 11952 Building Permit#: 38098 Section: 141 Block: 2 Lot: 14.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: home owner DBA: License No: SITE DETAILS Office Use Only Residential X Indoor Basement Service Only Commerical Outdoor x 1st Floor Pool New Renovation 2nd Floor Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt Ceiling Fixtures HID Fixtures Service 3 ph Hot Water GFCI Recpt Wall Fixtures Smoke Detectors Main Panel A/C Condenser Single Recpt Recessed Fixtures CO Detectors Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances Dryer Recpt Emergency Fixtures Time Clocks Disconnect rl Switches Ll Twist Lock Ll Exit Fixtures TVSS Other Equipment: 20KW stand by generator with auto transfer switch Notes: Inspector Signature: Date: Aug 19 2013 Electrical Certificate.xls FIELD REPORT DATE COMMENTS FOUNDATION(1ST) Q o�...r.r.q.pr.rr.r.rrrrro-rr.� m rA FOUNDATION(2ND) to ROUGH FRAMM Q& y PLUMBING � 00 IN&UL•ATION PEk N.Y. `3 STATE ENERGY CODE FINAL ADDITIONAL COMMENTS � m z C TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 11971 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. Check -� Septic Form N.Y.S.D.E.C. Trustees C.O.Application Flood Permit Examined & 13 ,20J3 Single&Separate Storm-Water Assessment Form Contact: Approved ! ,20 (, Mail to: r0 0,vk / 2S'-3 Disapproved a/c Phone: 63 2 `y Zoz35' Expiration 1 ,20 &A Building Inspector APPLICATION FOR BUILDING PERMIT Date , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application,the Building Inspector will issue a Building Pen-nit to the applicant. Such a permit shall be.kept on the premises available for inspection throughout the work. e.,No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing,the extension of the permit for an addition six months. Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The applicant agrees to comply with all applicable laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary.inspections. C��'F N�! (Signature of applicant or name, if a corporation) S. aG3 1z Uf� :6 d'U� a P,.eE, P d 1 1 L„ g E� w P't (Mailing address of applicant) �� _� y, ,�.,t�_i. , , APPR®� .,P J 1 E� State whefher applicant rs'owner, lessee, agent, architect, engineer, general cont ct r, e ec ician,p umber or builder DATE B.P. # 3 FEE BY Name of owner of premises 14,r i h i 4 oL M C, I(_ NOTn PWING D PARTiVIENT AT (As on the tax roll �� I PISPECTIONS: If applicant is a corporation, signature of duly authorized officer 1. FOUNDATION-TWO REQUIRED FOR POURED CONCRETE (Name and title of corporate officer) 2. ROUGH-FRAMING,PLUMBING, Builders License No. STRAPPING, ELECTRICAL&CAULKING Plumbers License No. 3. INSULATION 4. FINAL-CONSTRUCTION &ELECTRICAL Electricians License No. MUST BE COMPLETE FOR C.O. Other Trade's License'.No. ELF C T PH C A L ALL CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE CODES OF NEW � � � � �� "� YORK SPATE. NOT RESPONSIBLE FOR 1. Location of land on whic propose workvtibl'd7e. DESIGN OR ONSTRUCTION ERRORS, 3 © (1 s-- n r 9 g )9 Al`, House.Number Street Hamlet County Tax Map No. 1000 Section Block a Lot ��e j Subdivision Filed Map No. Lot , / 2. State existing use and occupancy of premises and intended use and occupancy of proposed construction: a. Existing use and occupancy b. Intended use and occupancy 3. Nature of work (check which applicable): New Building Addition Alteration Repair Removal Demolition Other Work G. cn (Description) 4. Estimated Cost Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories 9. Size of lot: Front Rear Depth 10. Date of Purchase Sip / 9'I Name of Former Owner CX14 rn 0 rn 11. Zone or use district in which premises are situated 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO 13. Will lot be re-graded? YES NO Will excess fill be removed from premises? YES NO 14. Names of Owner of premises Address Phone No. Name of Architect Address Phone No Name of Contractor Address Phone No. 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NO 'k IF YES, PROVIDE A COPY. STATE OF NEW YORK) SS: COUNTY OF ) being duly sworn, deposes and says that(s)he is the applicant (Name o signing f individual si nin contract above named CONNIE D. BUNCH . rac ) Notary Public,State of New York No.09 BU6185050 (S)He is the Qualified in Suffolk County (Contractor, Agent, Corporate Oflicer, etc.) Uomr nission Expires April 14,2Ut I- of said owner or-owners, and is duly authorized to perform or have performed the said wort:and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the'tnanner set forth in the application filed therewith. Sworn to before me;,this day of V_ - 20 F�_ Notary Public .Signature of Ap,16cant Q*Zf sn�ryp Town HO Amex > f f Telephone(631)765-1802, 54375 Main Road QWa7� rch 015. 1179 roger. T nY us Southold, . NY 1197I-0959 BUILDING DEPARTMENT TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL 1NSPECTtON REQUESTED BY: Date: Company Name: Name: License No.: Address: Phone No.: JOBSITE INFORMATION: (*Indicates required information) *Name: *Address: O 6 s-- (Z f- q j? *Cross Street: *Phone No.: (�.3/ 2 ?JF __ Z e73.S� Permit No.: �Q Tax-Map District: 1000 Sectibn: iyj Block: Lot: .1 'BRIEF DESCRIPTION OF WORK(Please Print Clearly) (Please Circle All That Apply) Is job ready for inspection: YES f`NO. Rough in Final *Do-you need a Temp Certificate: YES 1 NO Temp Information(lf needed) 'Service Size: 1 Phase 3Phase 100 150- 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION 82 Request for Enspecfion Form FRMUI+MR.FIRE NAIEDSIPANA110170 PAN1.717.11n p)OE OCCUPANCY DR NJ.STAII N10IDINGODOI, IU641�R USE IS UNLAWFUL ,ADO• N 1pTLn WI7NOUI CENTIFICAIE U' ^ f OF OCCUPANCY 0 � AS nODD� Q IJ� j DO NOT PROCEED VAIN . Na1lNoaDud1.N1 pA+°,tl"C1O��w*x vn '9M.nMwEro[D wuIAa q%� Ofi4DSIINC Ux,O SORVET ; Nl D7PUAEExnA9,Tn O0 L aI1"F L. 2 ': el murunwNcu W o�j2 0SH11 Au oux:,Nunes.sw.1,a, ,Nc N+aua+Llexn or,Nc IL< i d N 54 1 '2 SURVEY OF PROPERTY P \\�,b SITUATED AT -- jf24'R.POOL )�m ABOVE GR. MATTITUCK,TOWN OF SOUTHOLD A J (EXISTING) /i SUFFOLK COUNTY, NEW YORK / I - S.C.TAX NO-1000-141-02-14.001 EXISTING Wlx J=7 — DECK. 0.¢ - Z:O F WZ ¢1 4 24' I o Cc-----— I - W • PROPOSED GARAGE. - F- EXISTING c W1 1 -STORY a W'ii N FR.HOUSE EL t Ok CL. .Y 46' 'Lv i 1 O d O : �4is—;"A4y I s Win•,}� _ S.75"15'50"W. 138' ,a-r ALL INFORMATION TAKENy,NyE. FROM A SITE PLAN PREP PARED BY RODERICK VANTUYL,P. SITE DATED DULY 1 B.1973. _., PLA7,1 MIDDLE ROAD C.R. 27 • 'w ?•"'�'"„ SITE PLAN 1,6 SPECIFICATIONS E R 17kW 20MU 1 OtN� 10kW 1411ta1 Model 240 70.8 83.3 Rated Voltage 416 58.3 Rated MiIdmum Load Current(Amps)at 33.3 65 Amp 100 Amp 240 Volts(LP)* 45 AMP 60 Amp 35 Amp 1 Main Circuit Breaker_ 2 Phase Number of Rotor Poles 6D Hz Rated AC Frequency Group 26R 12 Volts and 525 CCA Minimum 455/421 450 Battery Requirement 387 `39 Aluminum 34g �� SteeVA►uminum weight(unit only In►bs.) Steel Steel For areas where tempera- Enclosura This unit is tested in accordance to UL 2200 standards with an operating temperature of 20"F(29°C)to C)ter(50°C. lures fall below 32°F(0°C),a cold weatirerIs orhighly recommended.When operated above 77°F(25°C}there may be a decrease In engine power. Normal Operating Range (please reiarence the engine specifica►►ons ) These generators are rated in accordance with tJL2200,Safely Standard for Stgonary Engine Generator Assemblies;and CS C22.2 No.100-04 Standard for Motors and Generators. s rilling. �i * Natural Gas ratings Will depend on specific fuel Btu content Typical Berates are between 10 0 nth m panel must be a 15 amp circuit in the transfer switch. **Circuits to be moved mast be protected by same size breaker. For e>camPle,a 15 amp 2 E 20 tW E kW 10 kW' 14/17 GT-999 8 Model kW G7 990 GH-410 'T-530 2 2 Type of Engine 1 2 36 18 Number of Cylinders 32 14.8 ' 999cc Rated Horsepower @ 3,600 rpm* 410cc 530cc 992cc Displacement Aluminum wtCast►ron Sleeve Cylinder Block Overhead Valves Valve Arrangement Solid-state w/Magneto RC12YG ignition System BPR6HS RC14YC 1.02 all m(O.D40.040 inch) 0.76 mm(0.030 Inch) 0.76 mm(0.030 inch) Recommended Spark Plug 0.76 mm(0.030 inch) 9,51 9,51 Spark Plug Gap 8.6:1 9.5:1 Compression Ratio 12 VDC Appro L 1.9 Ots Approx.'1. �- Starter Apprmr 19(its 7 Ots Oil Capacity Including Filter 1.5 Ots er part#0701 85F pal#OG5894 .Recommended Oil Filter pyrt#OG3332 Part#OE9581 part#OC8127 Recommended Air Riter 3,600 Operating RPM war decreases about 3.5 percent for each 1,000 feet above sea level;and * Engine power is subject to and limited by such factors as fuel Btu content,ambient temperature and allude.En g�power also will decrease about 1 percent for each C(10 F)above 16 C(60 F)ambient temperature. 6 INSTALLATION GUIDELINES Air-cooled Generators i R � r'�4., —�C �� W w�'n y'�$ 1,�af,3,� f��i .s•av ,.i�'�' a x. .c �" s r1 aC r�a� � � R `�a S ,� r N• h d,�' v �$ b`r s- ax - OFjrr-M �1!.24 , f- 4 i I TABLE OF CONTENTS INTRODUCTION Introduction.........................................................Inside Front Cover Thank you for purchasing this compact,high performance,air- Read this Manual Thoroughly .................................IFC cooled,engine-driven generator.It is designed to automatically g ry Contents................. ..........,...,..,.....,..............................1 supply electrical power to operate critical loads during a utility Operation and Maintenance....................................................1 power failure. How to Obtain Service............................................................1 This unit is factory installed in an all-weather,metal enclosure that Safety Rules...................................................................................1 is intended exclusively for outdoor installation.This generator Standards Index........................... .3 will operate using either vapor withdrawn liquid propane(LP)or ........................................ Unpacking/Inspection............................. natural gas(NG)...................................... 3 Protection Systems........................................................................3 NOTE: NEC Requirement for Arc Fault Circuit Interruption This generator is suitable for supplying typical Breaker for Bedrooms.................. .......................................3 residential loads such ,as Induction Motors (sump Section 210.12 Arc Fault Circuit Interrupter Protection............3 Pumps,refrigerators,air conditioners,furnaces,etc.), Electronic Components (computer, monitor, TV, etc.), Emission Information.....................................................................4 Lighting Loads and Microwaves. BeforeYou Begin............................................................................4 Site Preparation and Generator Placement..........................:...........4 READ THIS MANUAL THOROUGHLY Coverting to LP Vapor....................................................................5 If any portion of this manual is not understood,contact the Installing&Connecting Gas Lines..................................................6 nearest Dealer for starting,operating and servicing procedures. Battery Charger Installation.............................................................7 Throughout this publication,and on tags and decals affixed to the External Electrical Connections.......................................................8 generator, DANGER,WARNING,CAUTION and NOTE blocks are Generator Connections-Transfer Switch........................................8 used to alert personnel to special instructions about a particular Appendix A-Setting the Automatic Exercise Function...................1 o operation that may be hazardous if performed incorrectly or Installation Diagrams.......................... carelessly.Observe them carefully.Their definitions are as follows: ElectricalData..................................:...........................................14 A A Notes...........................................................................................32 After this heading, read instructions that, if not strictly complied with, will result in serious per- sonal injury, including death, in addition to prop- erty damage. ® WARNING A After this heading, read instructions that, if not strictly complied with, may result in serious per- sonal injury or property damage. A CAUTION ,A After this heading, read instructions that, if not j strictly complied with, could result in damage to equipment and/or property. NOTE: After this heading,read explanatory statements that require special emphasis. i These safety warnings cannot eliminate the hazards that they indicate.Common sense and strict compliance with the special instructions while performing the service are essential to preventing accidents. . Four commonly used safety symbols accompany the DANGER, SAFETY RULES WARNING and CAUTION blocks.The type of information each indicates follows: A WARNING A Q This symbol points out important safety informa- tion that, if not followed, could endanger per- 0 Save These Instructions—The.manufacturer suggests that these rules for safe operation be sonal safety and/or property of others. copied and posted near the unit's installation This symbol points out potential explosion site. Safety should be stressed to all operators • hazard. and potential operators of this equipment. A This symbol points out potential fire hazard. Study these SAFETY RULES carefully before installing,operating or servicing this equipment. Become familiar with this Owner's Q This symbol points out potential electrical shock Manua/and with the unit.The generator can operate safely, hazard. efficiently and reliably only if it is properly installed,operated and The operator is responsible for proper and safe use of the maintained.Many accidents are caused by failing to follow simple equipment.The manufacturer strongly recommends that the and fundamental rules or precautions. operator read this Owner's Manual and thoroughly understand all The manufacturer cannot anticipate every possible circumstance instructions before using this equipment.The manufacturer also that might involve a hazard.The warnings in this manual,and on strongly recommends instructing other users to properly start and tags and decals affixed to the unit are,therefore,not all-inclusive. operate the unit.This prepares them if they need to operate the If using a procedure,work method or operating technique the equipment in an emergency. manufacturer does not specifically recommend,ensure that it is safe for others.Also make sure the procedure,work method or CONTENTS operating technique utilized does not render the generator unsafe. This manual contains pertinent owner's information for these models: A ' A • 7 kW NG, 8 kW LP single-cylinder GH-410 Engine Q Despite the safe design of this generator, • 9 kW NG, 10 kW LP V-twin GT-530 Engine operating this equipment imprudently, neglect- * 13 kW NG, 14 kW LP V-twin GT-990 Engine ing its maintenance or being careless can cause • 16 kW NG, 17 kW LP V-twin GT-990 Engine possible injury or death. Permit only responsible • 18 kW NG,20 kW LP V-twin GT-999 Engine and capable persons to install, operate and maintain this equipment. OPERATION AND MAINTENANCE y Potentially lethal voltages are generated by It is the operator's responsibility to perform all safety checks,to these machines. Ensure all steps are taken to make sure that all maintenance for safe operation is performed render the machine safe before attempting to promptly,and to have the equipment checked periodically by a work on the generator. Dealer. Normal maintenance service and replacement of parts 0 Parts of the generator are rotating and/or hot are the responsibility of the owner/operator and, as such, are not during operation. Exercise care near running considered defects in materials or workmanship within the terms generators. of the warranty.Individual operating habits and usage contribute to 0 Installation must always comply with applicable the need for maintenance service. codes, standards, laws and regulations.. Proper maintenance and care of the generator ensures a minimum Q A running generator gives off carbon monoxide, number of problems and keep operating expenses at a minimum. and odorless, colorless poison gas. Breathing in See a Dealer for service aids and accessories. carbon monoxide can cause headaches, fatigue, diziness, nausea, vomitting, confusion, fainting, HOW TO OBTAIN SERVICE siezures or death. When the generator requires servicing or repairs,contact a Dealer for assistance.Service technicians are factory trained and are Mdefects 0capable of handling all service needs.When contacting a Dealer about parts and service,alwa s su I The engine exhaust from this product y ppY contains chemicals known to the state the complete model number and serial number of the unit as given"T its data decal,which l located on the generator.See section of California to cause cancer, birth "The Generator"for decal location. or other reproductive harm. Model No. Serial No. "cancer,swbirrto oduct contains or emits chemicals to the state of California to cause defects or other reproductive harm. 1 1 • After installing this home standby electrical system,the generator 0 GENERAL HAZARDS L11 may crank and start at any time without warning.When this occurs, load circuits are transferred to the STANDBY(generator) • For safety reasons,the manufacturer recommends that this power source.To prevent possible injury if such a start and equipment be installed,serviced and repaired by a Service Dealer transfer occur,always set the generator's AUTO/OFF/MANUAL or other competent,qualified electrician or installation technician switch to its OFF position before working on equipment and who is familiar with applicable codes,standards and regulations. remove the 15A fuse from the generator control panel. The operator also must comply with all such codes, standards • In case of accident caused by electric shock,immediately shut and regulations. down the source of electrical power.If this is not possible,attempt • The engine exhaust fumes contain carbon monoxide,which to free the victim from the live conductor.AVOID DIRECT CONTACT can be DEADLY.This dangerous gas, if breathed in sufficient WITH THE VICTIM.Use a nonconducting implement,such as a dry concentrations,can cause unconsciousness or even death. Do rope or board,to free the victim from the live conductor.If the victim NOT alter or add to the exhaust system or do anything that might is unconscious,apply first aid and get immediate medical help. render the system unsafe or in noncompliance with applicable • Never wear jewelry when working on this equipment.Jewelry can codes and standards. conduct electricity resulting in electric shock,or may get caught in • Install a battery operated carbon monoxide alarm indoors, moving components causing injury. according to manufacturer's instructions/recommendations. AN FIRE HAZARDS • Adequate,unobstructed flow of cooling and ventilating air is critical to correct generator operation. Do not alter the installation • For fire safety,the generator must be installed and maintained or permit even partial blockage of ventilation provisions,as this properly.Installation must always comply with applicable can seriously affect safe operation of the generator.The generator codes,standards,laws and regulations.Adhere strictly to local, MUST be installed and operated outdoors only. state and national electrical and building codes.Comply with • Keep hands,feet,clothing,etc.,away from drive belts,fans,and regulations the Occupational Safety and Health Administration other moving or hot parts.Never remove any drive belt or fan (OSHA)has established.Also,ensure that the generator is guard while the unit is operating. installed in accordance with the manufacturer's instructions and • When working on this equipment, remain alert at all times. Never recommendations.Following proper installation,do nothing that work on the equipment when physically or mentally fatigued. might alter a safe installation and render the unit in noncompliance • Inspect the generator regularly,and contact the nearest Dealer for with the aforementioned codes,standards, laws and regulations. parts needing repair or replacement. • Keep a fire extinguisher near the generator at all times. • Before performing any maintenance on the generator,disconnect Extinguishers rated ABC"by the National Fire Protection its battery cables to prevent accidental start up. Disconnect the Association are appropriate for use on the standby electric system. cable from the battery post indicated by a NEGATIVE,NEG or Keep the extinguisher properly charged and be familiar with its use. (—)first,then remove the POSITIVE, POS or(+)cable.When Consult the local fire department with any questions pertaining to reconnecting the cables,connect the POSITIVE cable first,the fire extinguishers. NEGATIVE cable last. • Never use the generator or any of its parts as a step.Stepping on ® EXPLOSION HAZARDS the unit can stress and break parts,and may result in dangerous g Do not smoke around the generator.Wipe up any fuel or oil spills operating conditions from leaking exhaust gases,fuel leakage,oil immediately.Ensure that no combustible materials are left in the leakage,etc. generator compartment,or on or near the generator,as FIRE or QEXPLOSION may result. Keep the area surrounding the generator ELECTRICAL HAZARDS 0 clean and free from debris. • All generators covered by this manual produce dangerous • Gaseous fluids such as natural gas and liquid propane(LP) electrical voltages and can cause fatal electrical shock. Utility gas are extremely EXPLOSIVE. Install the fuel supply system power delivers extremely high and dangerous voltages to the according to applicable fuel-gas codes. Before placing the home transfer switch as does the standby generator when it is in standby electric system into service,fuel system lines must be operation.Avoid contact with bare wires,terminals,connections, properly purged and leak tested according to applicable code. etc.,while the unit is running.Ensure all appropriate covers, After installation,inspect the fuel system periodically for leaks.No guards and barriers are in place,secured and/or locked before leakage is permitted. operating the generator. If work must be done around an operating unit, stand on an insulated,dry surface to reduce shock hazard. 0 ENGINE EXHAUST HAZARDS �! • Do not handle any kind of electrical device while standing in water, • Generator engine exhaust contains DEADLY carbon monoxide,an while barefoot,or while hands or feet are wet. DANGEROUS odorless,colorless poisonous gas. Breathing carbon monoxide ELECTRICAL SHOCK MAY RESULT. can cause:dizziness,throbbing temples,nausea, muscular • The National Electrical Code(NEC)requires the frame and external twitching,headache,vomiting,weakness and sleepiness, inability electrically conductive parts of the generator to be connected to an to think clearly,fainting, unconsciousness or even death. If you approved earth ground.Local electrical codes also may require proper experience any carbon monoxide poisoning symptoms,move into grounding of the generator electrical system. fresh air and immediately seek medical attention. • Never operate the generator set with the vehicle inside any garage or other enclosed area. 2 r STANDARDS INDEX If any loss or damage is noted at time of delivery,have the In the absence of pertinent standards,codes,regulations and person(s) making the delivery note all damage on the freight bill laws,the published information listed below may be used for or affix their signature under the consignor's memo of loss or installation guidance for this equipment. damage. 1. NFPA No.37,STATIONARY COMBUSTION ENGINES AND GAS If a loss or damage is noted after delivery,separate the damaged TURBINES,available from the National Fire Protection Association, materials and contact the carrier for claim procedures. 470 Atlantic Avenue,Boston,MA 02210. "Concealed damage"is understood to mean damage to the 2. NFPA No.76A,ESSENTIAL ELECTRICAL SYSTEMS FOR HEALTH contents of a package that is not in evidence at the time of CARE FACILITIES,available same as Item 1. delivery,but is discovered later. 3. NFPA No.54,NATIONAL FUEL GAS CODE,available same as Item 1. To properly open the roof,press down on the center top lip and 4. NFPA No.58,AMERICAN NATIONAL STANDARD FOR STORAGE release the latch. If pressure is not applied from the top,the roof AND HANDLING OF LIQUEFIED PETROLEUM GAS,available same may appear stuck.Always verify that the side lock is unlocked as Item 1. before attempting to lift the roof. 5. NFPA No.70,NFPA HANDBOOK OF NATIONAL ELECTRIC CODE, PROTECTION SYSTEMS available same as Item 1. 6. Article X,NATIONAL BUILDING CODE,available from the American Unlike an automobile engine,the generator may have to run for Insurance Association,85 John Street,New York,N.Y.10038. long periods of time with no operator present to monitor engine 7. AGRICULTURAL WIRING HANDBOOK,available from the Food and conditions. For that reason,the engine is equipped with the Energy Council,909 University Avenue,Columbia,MO 65201. following systems that protect it against potentially damaging 8. ASAE EP-3634,INSTALLATION AND MAINTENANCE OF FARM 'conditions: STANDBY ELECTRICAL SYSTEMS,available from the American Society of Agricultural Engineers,2950 Niles Road,St.Joseph,MI 1. Low Oil Pressure Sensor 49085. 2. High Temperature Sensor 9. NFPA No.30,FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE, 3. Overcrank available same as Item 1. 4. Overspeed 5. RPM Sensor A A 6. Low Battery There are readouts on the control panel to notify personnel that 0 Only qualified electricians or contractors should one of these failures has occurred. There is also a System Set attempt such installations,which must comply LED (single cylinder)or a Status message on the display(V-twins) strictly with applicable codes, standards and regu- lations. p y that dis la s when all of the conditions described in the"System Set LED"section are true. UNPACKING/INSPECTION After unpacking,carefully inspect the contents for damage. NEC REQUIREMENT FOR ARC FAULT CIRCUIT • This standby generator set is ready for installation with a INTERRUPTION BREAKER FOR BEDROOMS factory supplied and pre-mounted base pad and has a weather In 2001,the National Electric Code(NEC) introduced a protective enclosure that is intended for outdoor installation requirement for new construction.This new requirement indicates only, the need for Arc Fault Circuit Interrupters to be used to protect the • This UL listed standby generator set may be packaged with complete branch circuit that feeds a dwelling bedroom.The actual an automatic transfer switch with built in load center.The combination transfer switch and load center is pre-wired with NEC requirement is indicated below. a two foot and 30 foot conduit.Circuit breakers for emergency . circuit connections are included(if equipped). ♦ SECTION 210.12 ARC FAULT CIRCUIT INTERRUPTER • This UL listed,2-pole switch is rated at 100 or 200 AC amperes PROTECTION at 250 volts maximum.The 100 Amp transfer switch is for indoor use only.The 200 Amp transfer switch is for indoor/ 1. Definition: An arc fault circuit interrupter is a device outdoor use .(if equipped), intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by -A WARNING A functioning to de-energize the circuit when an arc fault is detected. Ay If this generator is used to power electrical load 2. Dwelling Unit Bedrooms: All branch circuits that supply circuits normally powered by a utility power 125 volt,single-phase, 15 and 20 ampere outlets installed source, it is required by code to install a transfer in dwelling unit bedrooms shall be protected by an arc fault switch. The transfer switch must effectively isolate circuit interrupter listed to provide protection of the entire the electrical system from the utility distribution branch circuit. system when the generator is operating (NEC 700, 701 & 702). Failure to isolate an electrical system by such means will result in damage to the gen- erator and also may result in injury or death to utility power workers due to backfeed of electrical energy. I 3 I I Section 210.12 requires that AFCI protection be provided on branch circuits that supply outlets(receptacle, lighting,etc.) Displacement Category Compliance Period in dwelling bedrooms.The requirement is limited to 15 and 20 A 300 Hours ampere, 125 volt circuits.There is no prohibition against providing AFCI protection on other circuits or in locations other than < 66 cc B 125 Hours bedrooms. Because circuits are often shared between a bedroom C 50 Hours and other areas such as closets and hallways,providing AFCI protection on the complete circuit would comply with 210.12. z 66 cc- A 500 Hours If during the installation of the home standby system the decision B 250 Hours is made to provide back u power to a bedroom branch circuit, < 225 cc P P P C 125 Hours then the circuit breaker in the transfer switch should be replaced A 1000 Hours with an Arc Fault Circuit Interrupter. It is most important that breakers only be switched like for like. z 225 cc B 500 Hours For instance,if replacing a 15A breaker,it MUST be replaced with C 250 Hours a 15A AFCI breaker. Likewise,a 20A breaker MUST be replaced with a 20A AFCI. BEFORE YOU BEGIN These AFCI breakers are available at the nearest hardware store. Contact the local inspector or City Hall to be aware of all federal, Eaton Cat# Description state and local codes that could impact the installation.Secure all BR115AF 1"15A Single Pole AFCI required permits before starting the job. CH115AF 3/4"15A Single Pole AFCI Carefully read and follow all of the procedures and safety BR120AF 1"20A Single Pole AFCI precautions detailed in the installation guide.If any portion of the CH120AF 3/4"20A Single Pole AFCI installation manual,technical manual or other factory-supplied documents is not completely understood,contact a dealer for EMISSION INFORMATION assistance. f The Environmental Protection Agency requires that this generator complies with exhaust emission standards.This generator is Fully comply with all relevant NEC,NFPA and OSHA standards certified to meet the applicable EPA emission levels.Additional as well as all federal,state and local building and electric codes. information regarding the requirements set by the EPA is as As with any generator,this unit must be installed in accordance follows: with current NFPA 37 and NFPA 70 standards as well as any other The generator is certified for use as a stationary engine for federal,state,and local codes for minimum distances from other standby power generation.Any other use may be a violation structures. of federal and/or local laws. It is important that to follow the maintenance specifications in the"Maintenance"section to SITE PREPARATION AND GENERATOR ensure that the engine complies with the applicable emission PLACEMENT standards for the duration of the engine's life.This engine is certified to operate on Liquid Propane fuel and pipeline Natural Gas.The emission control system on the generator consists of the following: • Fuel Metering System ! i • Carburetor/mixer assembly • Fuel regulator • Air Induction System - • Intake pipe/manifold • Air cleaner • Ignition System • Spark plug • Ignition module 1. Locate the mounting area as close as possible to the transfer The Emissions Compliance Period referred to on the Emissions switch and fuel supply. Compliance Label indicates the number of operating hours for Leave adequate room around the area for service access which the engine has been shown to meet Federal emission (check local code),and place high enough to keep rising requirements. See the table below to determine the compliance water from reaching the generator. period for the generator.The displacement of the generator is Choose an open space that will provide adequate and listed on the Emissions Compliance Label. unobstructed airflow(see the"Location"section in the Owner's Manual). i 4 i r.y .� 7. w^f'�. i 4 E:T•111 �� 2. Place the unit so air vents won't become clogged with leaves, 5. Set the generator onto the pad so that the gravel bed extends several inches beyond the generator on all sides. grass,snow or debris. Make sure exhaust fumes will not enter Make sure the generator is level within�/z inch. the building through eaves,windows,ventilation fans or other air intakes. Refer to the local codes and standards for the proper distance between the unit and the building/structure. MEN w Dig a rectangular area approximately five inches deep and about six inches longer and wider than the footprint of the generator.Cover with polyurethane film and fill with pea gravel t. v •' or crushed stone.Compact and level the stone.A concrete pad can be poured if desired. 6. Connect an approved ground strap to the grounding lug on the Y' I base frame and to an approved earth ground or grounding rod i as specified by local regulations. 7. Check the engine oil and,if necessary,add enough of the =v_ . recommended oil to bring the level up to the FULL mark on the dipstick Be careful not to overfill the crankcase. i 3. Inspect the generator for shipping damage and if necessary, file a claim with the shipper. ,� f Remove the bands holding the generator to the wooden pallet. CONVERTING TO LP VAPOR o r,. i..• 4 I. i� 4. Make sure the lifting equipment to be used has sufficient capacity to safely handle the weight of the generator. Use nylon lifting straps and connect them to the lifting eyes on each corner of the base frame to avoid damaging the enclosure. 1. The generator was configured for natural gas operation at the factory.Switching over to LP Vapor is a simple procedure. On models with a single cylinder engine, begin by disconnecting and removing the battery if installed. 5 6. On all other models, simply remove the air cleaner cover and Y slide the fuel selector pin outward from the natural gas to the z LP position. INSTALLING & CONNECTING GAS LINES 6 2. Take the plastic T-handle fuel selector in the poly bag supplied with the generator and locate the selector tab on the air box " cover.Insert the pin end into the hole in the selector tab • c du r� q ; and pull outward to overcome spring pressure.Then twist '3,; ,,�i,,-,T.,��.�y•.* �'s•'�•M'�� i clockwise 90 degrees and allow the selector to return in once f' :; aligned with the LP position. 1. Both natural gas and LP Vapor are highly volatile substances, so strict adherence to all safety procedures,codes,standards and regulations is essential. Fuet selection Gas line connections should be made by a certified plumber Leve►•°In' familiar with local codes.Always use AGA-approved gas pipe Position for and a quality pipe sealant or joint compound. Feel Verify the capacity of the natural gas meter or the LP tank in regards to providing sufficient fuel for both the generator and other operating appliances. tA - a3wu W r.'.:i f.4ww" � F D*b•'-`!A! 'd i 3. On 10 kW units,open the roof,loosen the forward clamp -40 on the air inlet hose,and slide the hose away from the hose A' fitting µ fikN M t'J Fuel Selection If Lever-"Out' Position forr4 w sr � Liquid Propane O,. (Vapor)Fuel 2. Most applications will require an external manual shutoff valve ., r on the fuel line. F ! 4r 4. Slide the fuel selector pin on the carburetor out towards the back of the enclosure. 5. Replace the inlet hose and tighten the clamp securely. Fuel Selection Lever-"Out"Position for Liquid Propane (Vapor)Fuel ' 3. Where the gas line is to enter the generator, install a T-fitting ,�, i:' �� x fin• to allow for gas pressure monitoring. On one opening of the .. � fitting install a'/a"NPT nipple and threaded plug. In some ry p cases a sediment trap may also be installed. 6 i „_�.. �,�i.�.`.�^'L,�i1'f�"S�L�S°I,M�„k3.,,•.i,�... ���°,F}t � s�'#s;,� ::v„'Yz* '+Ss;• x:: � r c•.'�"!}'w/: .•a.. ZION �►.. 7^'l''�.'aa ,-:., 'ter. �^ H�i v 4. When connecting the gas line to the generator,use the 7. When finished checking the gas pressure,close the manual provided section of UL Listed or AGA-approved flexible fuel shutoff valve. line in accordance with local regulations.The purpose of the flexible fuel line is to ensure that vibration from the generator BATTERY CHARGER INSTALLATION does not cause a gas leak at one of the connection points,so it's important that the line be installed with as few bends as ry possible. 4,' t t,. A i 1. For applications with Eaton transfer switches the charger f y needs to be mounted in the generator. 2. This battery charger supplies a trickle charging current and 5. Never bend the flexible fuel line to avoid using an elbow. voltage to maintain the charge on the generator starting Bending the flexible line decreases its ability to absorb battery inside the generator enclosure.The charger will vibrations and defeats its purpose as well as constricts the not replenish a fully discharged battery. It is intended to be actual fuel flow. connected to a 120 or 240 VAC generator backed-up circuit only. If it is not connected to a generator backed-up circuit the battery could go"dead”while the generator is running for extended periods of time. Mount the 5amp 600V fuses and holders in the transfer switch.Transfer switches will not have holes pre-drilled for M ^, . the fuse holder.;it is necessary to drill holes in the enclosure to mount the fuse holder. 7r,4a4 a 4. Connect one side of the fuse to terminal(T1)and the other to 5 (T2)of the transfer switch using a spade lug. Remove the cover over the controller in the generator. Identify the DC output wires on the battery charger and crimp spade f a ; lugs onto both the positive and negative lead. 6. Attach the positive and negative battery charger leads to the terminal strip in the controller.The positive lead is either 6. After checking for leaks,check the gas pressure at the a red wire or is marked with a(+)or(15B)designation. T-fitting installed earlier to make sure there's enough pressure The negative lead is black and/or marked with a (-)or(0) for proper generator operation. designation.The positive lead attaches to the terminal labeled The local gas supplier is responsible for ensuring adequate 1513".Note that there will be two wires attached to the 1513" pressure,so if the pressure is too low,or if it's greater than terminal when the full installation is completed. One for the 14 inches of water column,contact the gas supplier. battery charger and one.for the common connection to the transfer switch.The negative lead attaches to the terminal labeled"0". I i 7 i NOTE: Connect all wires to the lugs in the connection box(black to black, See the appropriate EGS Installation/Wiring Diagram red to red and white to white).Attach the green ground wire to in the "Interconnection Diagrams" section for con- the ground screw and connect the two small plugs to their mating nections. receptacle ends. 7. If already connected,disconnect the battery in the generator. OP k r Remove the negative(-)cable first,followed by the positive )P , ` =t (+) cable.Take care not to short the cables together. ' B. Ensure power is applied to the battery charger input.Connect a volt meter across the battery leads.The voltage reading should be between 12.8VDC and 13.8VDC. 0 9. If the voltage is within range installation of the battery charger is complete. If the voltage is not within range verify all wiring and sizing and retest. y 10.Re-connect the battery cables.Positive cable first followed by the negative cable. 4. Replace the protective cover plate and retaining screw,and lock the connection box. EXTERNAL ELECTRICAL CONNECTIONS f ur.sa°' r' , E,. ,c(' •-.. � d �' $'� f4 P ,Yq-,,i r c ✓gym �` .�;,tar 31 "Pup � 5 mA }} 5. For 10-20 kW models,locate the metal hasp that is packaged 1. Drill a 1 1/4 inch hole and feed the conduit through the hole. in the owner's manual bag. Insert the hasp in the slot located on the left side of the external circuit breaker box.Be sure that the clip of the hasp is facing toward the front of the generator. If desired,lock the external-box. GENERATOR CONNECTIONS TRANSFER M SWITCH 1. If the Load Center transfer switch was purchased separately ' from the generator it will need to be connected to the fi generator.To complete the wiring,run power leads and control wires from the transfer switch to the generator. 2. Remove the knockout in the back of the connection box(if used),feed the wires through the back of the box and secure the conduit with the lock nut. �y Seal the hole with silicone caulk.Don't forget to caulk the hole inside the house as well. e.,2, R 2. Remove the two screws securing the connection area cover, I` and remove the cover. n w4 3. Mount the connection box(if used)so that it completely covers the hole in the wall.Caulk around the sides and top of the box to ensure a good seal. 8 i 7. Remove the plastic plugs inside the main breaker access area to allow connection of the power leads to the circuit breaker. t it F. 3. Feed the wires through the back of the generator and secure the conduit with the lock nut. 1 8. Now connect the red and black power leads to the circuit breaker.Since this is a single-phase application,it doesn't matter which wire is connected to which lug. 4. Run the power leads through the strain relief provided. 3 9. Connect the green equipment ground wire to the ground stud ,•,r;; �_ and torque to 80 inch lbs. 75, 5. On 8 kW units,the main breaker is located inside the a � generator at the rear of the connection area. , r K � I e� Y, 110.Connect the white neutral wire to the neutral post and torque k . to 100 inch lbs. , r ail #1 __ r •� 6. For all other models the circuit breaker is attached to their exterior access panel. I A Y rr , :. 11.Connect the control wires to the correct terminals. The terminals are clearly marked N1, N2. 9 yy t r ' w:11'•LYI n r� :�fry..+ �,y 12.An improperly connected control wire can damage the generator control board. 5. If the exercise time or day ever needs to be changed,press 13.Transfer switch connections are covered in the Owner's the escape key to access the main menu. Manual that was shipped with the generator APPENDIX A - SETTING THE AUTOMATIC EXERCISE FUNCTION ' �t 6. Press the left or right arrow key until'Edit'is flashing and press enter. 1. To set the exercise on 8 kW models, make sure with the mode R. switch is in AUTO.Press and hold down the EXERCISER switch for at least 10 seconds and release.The generator should ,,t start within a few seconds.The unit will run for about 12 minutes before shutting itself down automatically. rag 2. If the battery is ever disconnected or the fuse is removed for y any reason,the exercise function will have to be reset. 7. Press the right or left arrow key until the exercise time is 7 displayed and press enter. 2 t f1'"Yi 3. On all other models,the display will enter an Installation Assistant mode when battery power is first connected.The assistant will 8. Using the arrow and enter keys first set the exercise hour in prompt to first enter the current date and time,followed by the 24 hour format,followed by the minute,and finally the day. exercise day and time, 4. If the battery is ever disconnected and reconnected,or fuse removed and replaced,the Installation Assistant will be displayed again,but only the current date and time will need to be entered. f i 10 � a + I; E sr� 52 � 9. Once set,the generator will exercise each week at the same time. Be sure to show the owners how to set the exercise function for the day and time they want the unit to exercise. yl%wib Y 10. If the generator is equipped with the low speed exercise feature, it was enabled,at the factory and no adjustment is needed. Every installation has its own unique set of circumstances and requirements.This booklet provides guidelines for basic I installations only and is not intended to cover all applications. If there are any questions or concerns after carefully reading all documentation received with the equipment,contact the nearest �. dealer for assistance. I E I 11 N Z IIIIII' a r . r � a POWER LEADS AND TRANSFER SWITCH LEADS Z MUST BE RUN IN TWO DIFFERENT CONDUITS. EXCEPTIONS: IF THE INSULATION RATING ON ALL WIRING IS RATED FOR 500V AND THE LENGTH OF THE CONDUIT IS 30 ft OR LESS IT IS ACCEPTABLE -i GROUNDING ROD TO INCLUDE GENERATOR CONTROL AND �' O (ELECTRODE) POWER WIRING IN ONE CONDUIT C� y O lb GROUNDING ELECTRODE I Z m _ CONNECTION _ O CL O (ON REAR OF UNIT) '—— N 7 O O � d E to E2 J 1 NEUTRAL rr, N I i ®° V! I m d N2 Ni ¢ "'z I D) n o o CUSTOMER LOAD Tz E1 E2 SAM7 ® O) CD (DISTRIBUTION PANEL) TI BC NNE FUSE e \ I BC NNE FUSE •O �yy II 5 fD �% II UTILITY SUPPLY FROM II ® ® UTILITY DISCONNECT II N2 NI I G ue U—J o II o II �1 I NI N2 sees NOTE: caouND INSTALLATION TO BE DONE BY A LICENSED ELECTRICIAN AND MUST MEET ALL NATIONAL,STATE AND LOCAL ELECTRICL CODES. e e e TYPICAL FOR ALL EATON NON-SERVICE ENTRANCE RATED TRANSFER SWITCHES POWER LEADS AND TRANSFER SWITCH LEADS MUST BE RUN IN TWO DIFFERENT CONDUITS. EXCEPTIONS: IF THE INSULATION RATING ON ALL WIRING IS UTILITY RATED FOR 600V AND THE LENGTH OF THE CONDUIT IS 30 ft OR LESS IT IS ACCEPTABLE METER GROUNDING TO INCLUDE GENERATOR CONTROL AND SOCKET (ELECTRODEE)) POWER WIRING IN ONE CONDUIT I GROUNDING ELECTRODE � CONNECTION (ON REAR OF UNIT) -- ❑ ❑ I I 1 E I E2 I NEUTRAL I N2 N7 1 ® m 1 ° CUSTOMER LOAD E1 E2 ® O) ° (DISTRIBUTION PANEL) Tl BcuNe Fuse ®,� � 1 "� BC LBIE RAA MP ® �n ow ® II ® ® N2 Nt I I� r a o 0 0 11 s o 72. o II � 01 o°o II y D 3 a O II a 000vo N rt 11 ®eke® 2 d ra II m a 0 d L 4 easen'dP NI f�D NOTE: GROUND � Rt O INSTALLATION TO BE DONE BY A LICENSED ELECTRICIAN AND H N MUST MEET ALL NATIONAL,STATE AND LOCAL ELECTRICL CODES. e e e TYPICAL FOR ALL EATON SERVICE ENTRANCE RATED TRANSFER SWITCHES II�III, cn Z r O w Z Electrical Data Wiring Diagram-8kW—Drawing No.OG7945-A ELECTRICAL ~ DATA --► ENGINE COMPARTMENT CONTROL PANEL r 1 K I w Z rz I Z) N O m CAPACITOR i z Z + I I I I I �1 1 1 m 6 I Z N I I I I 22 I 1 33 1 I STATOR 4 I 1 11 1 1 I I I 1 I 1 I I 1 1 I I I I I I 1 1 I 1 1 I 1 1 I 1 O I I 1 I SP1 I 0 0 IM1 1 1 i N1 N2 I I 1 I I I L_ __ J 1 1 I 1 I I I 85 85 1 86 86 2 MAIN J1 CONTROLLER 13 3 18 4 HTO I LOP 1 i I 0 J2 1 2 3 4 5 6 7 8 9 101112131415161718 i � 15B I 1 I 23 RED i 56 I I 21 I I CHOKE 0 1 OLENOID 1 I I B 13 I 1 I 0 � 14- � I i 1 I o I SM 1 56 i I I SC i 56 56 0 p 0 0 0 I 0 O 0- p 13 PANEL GND j ENGINE GND FRAME a-0 O 0 i rl GND 1 14 Electrical Data Wiring Diagram-8kW—Drawing No.OG7945-A 77ELECTRIC7AL 240V GENERATOR CUSTO MER CONNECT AREA � Z < OUTPUT TO TRANSFER 0 w SWITCH CONTACTOR o Z CB Q I 0 o I N M O 1 I ' s s 1 I I 1 1 I I I a I 1 1 44� I I 11 I I 1 I I I 1 � I I 1 ,----------------------- LEGEND I CB - CIRCUIT BREAKER, MAIN OUTPUT GND - GROUND HTO - HIGH TEMPERATURE SWITCH I IM1 - IGNITON MODULE LOP - LOW OIL PRESSURE SWITCH I I SC - STARTER CONTACTOR SM - STARTER MOTOR SP1 - SPARK PLUG O- SPLICE I I I , I , I , I I I I I I 1 I I I I I 1 , 1 I I 1 I � 1 I I � I 1 ---------------------------------------------ff47l7 I F1777 I � I � FUEL I � 14 OLENOID N1 00 ` � I I , I � I I I BATTERY WARMER I 1 -14 I I OPTIONAL RED 13 ------ ---------- ------I I I I , I , 1 NOTE: ALL WIRES 18 AWG I f D I T — � 300V UL LISTED UNLESS —0 i 12V SHOWN OTHERWISE BATTERY i AWG SIZE i I I I � I CUSTOMER SUPPLIED L-----------------------I 15 Electrical Data Electrical Schematic-8kW—Drawing No.0G8511-A ELECTRICAL ;- DATA_ EXCITATION WINDING CB 2 6 j CAPACITOR f � 240 VAC ---------- GENERATOR POWER _ 11� OUTPUT WINDING 44 33 STATOR 2233 � NEUTRAL 22 ; POWER WINDING i i 240 VAC UTILITY OPTIONAL INPUT BATTERY WARMER N1 N2 IM 18 SP 85 1 f N1 N2 86 2 J1 13 3 CONTROLLER 18 4 PRINTED CIRCUIT BOARD I I J2 85 66 1 2 3 4 5 6 7 8 9 0 1112 1314 1516 1718 1 14 23 15B 0 56 I• THTD LOP 0 0 56 56 CS SC FS GROUND 58 + BATTERY 0 0 0 23 '3 113 1 BATTERY - Y2V TSG 0 16 �0 SM LEGEND CB - CIRCUIT BREAKER, MAIN OUTPUT LOP - LOW ❑IL PRESSURE SWITCH CS - CHOKE SOLENOID SC - STARTER CONTACTOR FS - FUEL SOLENOID SM - STARTER MOTOR HTO - HIGH TEMPERATURE SWITCH SP - SPARK PLUG IM - IGNITION MODULE i 16 Electrical Data 1'"M7 9000 Electrical Schematic-10kW—Drawing No.OG8512-A t- ELECTRICAL --► DATA EXCITATION WINDING 2 i---------i CB CAPACITOR L---------J r-44----® 240 VAC GENERATOR POWER -11 --a OUTPUT WINDING 44 STATOR 22 33 33 ' NEUTRAL 22 i 11 r--------------------------------- POWER i ---00-------. WINDING I i i 240 VAC UTILITY IM2 18 INPUT SP2 OPTIONAL BATTERY WARMER Ni N2 IM1 18 SP1 LED BOARD 1 N1 N2 86 2 13 3 CONTROLLER 18 4 PRINTED CIRCUIT BOARD 1 2 3 4 J3 J2 N n Go 85 86 Go m Go Go f 1 1 2 3 4 5 6 7 8 9 10 1112 1314 15 16 17 18 i 0 14 23 1 B 6 THTO 7 Lop GOVERNOR ACTUATOR 0 0 14 82 14 818 817 C f FS FS 1 0 GROUND 0 0 15B + BATTERY 23 13 13 13- BATTERY— 12V — f SCR 1 T 0 IO 16 sC I; sM LEGEND � CB - CIRCUIT BREAKER, MAIN OUTPUT LOP - LOW ❑IL PRESSURE SWITCH CS - CHOKE SOLENOID SC - STARTER CONTACTOR FS - FUEL SOLENOID SCR - STARTER CONTROL RELAY HT❑ - HIGH TEMPERATURE SWITCH SM - STARTER MOTOR IM- - IGNITION MODULE SP- - SPARK PLUG 17 Electrical Data Wiring Diagram-10kW—Drawing No.OG7946-A ELECTRICAL ~ DATA 11- ENGINE COMPARTMENT i CONTROL PAS } 1 � I ~w z ~ I D I CAPACITOR i N o m z z + 1 1 0 I I � 6 i m I Z O 2 N I I I I 22 1 1 1 3 1 STATOR 44 1 10 j I 11 I 1 I I I I I I I 1 1 I I I I I i I I 1 N.C. N.C. p � IC IC I I SP1 i 1 I 1 IM1 18 i 0 '4 (_ N1 N2 I I. SP2 i 12k 1 1 I 0 0 IM2 I I I 85 I 85 1 86 86 2 J1 MAIN 1 13 3 CONTROLLER i 1I i 18 4 HTOLOP 0 0 19 J3 J2 1 2 3 4 5 6 7 8 9 1 011121 141561712815 83 820 RED- 1 14 14 817 21 8188 CHOKE I 90 8 1 OENOIDK 0 BIL OVERNO CTUATO 0 L— 14 I. 1 14— I 1 0 I 0 1 I . 13 1 16 SM i SCR ; 13 I A B 13 SC 0 0 j 56 0 0 0 13 16 1 0 O 0— .0 PANEL GND ENGINE . FRAME GND 18 Electrical Data Wiring Diagram-1 OkW—Drawing No.OG7946-A 7ELECT7RICAL 240V GENERATOR CUSTOMER CONNECT AREA � z OUTPUT TO TRANSFER o SWITCH CONTACTOR K w z CB O O y O N M O N M O o 0 ' g -LL44 n CB - CIRCUIT BREAKER, MAIN OUTPUT i GND - GROUND HTO - HIGH TEMPERATURE SWITCH IM- - IGNITON MODULE LOP - LOW OIL PRESSURE SWITCH i SC - STARTER CONTACTOR SCR - STARTER CONTROL RELAY SM - STARTER MOTOR i i SP- - SPARK PLUG SPLICE DISCONNECT SPLICE LED BOARD IC 820 1 817 2 L1 0 818 3 L3 L1: GREEN = SYSTEM READY i 819 4 1-3: RED = ALARM i � i 4 ' -------------------- Fl-41 - i L------------------------------------------------------------Fl:fl -----------------, FUEL i � I 14 OLENOID i FUEL 14 OLENOID 0 Ni 00 i � � I BATTERY WARMER -14 ' OPTIONAL i i 0 r----- ---------- ------1 i NOTE: ALL WIRES 18 AWG 0 i + — i 300V UL LISTED UNLESS —0 i 12V i SHOWN OTHERWISE BATTERY i AWG SIZE CUSTOMER SUPPLIED 19 Electrical Data Wiring Diagram-14kW—Drawing No.OG7947-A ELECTRICAL F DATA ENGINE COMPARTMENT CONTROL PANEL r 2 2 I 0 s g VOLTAGE 0 a 0 0 REGULATOR z z 4 } I 4 0 0 0 1 22qlCICl 2 1111 0 I � I 1 m 2 I Z m N I 1 rM I I 22 2 33 I 0 CLOSEST TO BEARING STATOR 44 BA I FM 0 11 F 4 I I I 1 1 I I 4 1 I I I I 1 I I , I I 0 SP1 O I 1 0 IM1 I 18 i N1 N2 1 _ i A SP2 I I I I 1 *IM2 1 I 85 ; 8s 1 86 I 86 2 J1 MAIN 1 13 3 CONTROLLER 18 4 40, I i J3 1 I J2 1 1 2 3 4 5 6 7 8 9 101112131415161718 I I 15B 1 I I 23 8820 RED 14 i 14 818 2 CHOKE 1 90 90 819 0 ENOID `---J i p I I 1 0 BLK � I 1 I I GOVERNO 0 CTUATO 14 14— I I 0 I i I 1 i 16 SM SCR 13 A 8 I 13, 0 3 SC i 56 0 0 0 0 13 16 0 O 0— 1 I 0 PANEL GND ENGINE 1 GND FRAME GND a-0 O 0 I f2i1 I 20 Electrical Data Wiring Diagram-14kW—Drawing No.OG7947-A ELECTRICAL ~ DATA -+ CUSTOMER .ONN T AREA o -� 240V GENERATOR OUTPUT TO TRANSFER O SWITCH CONTACTOR w Z CB O O N M O N M O I I NN O O 1 I I I I I � 1 � I I I 44. I 1 I 1 I I I I ------------------ ---- LEGEND I BA - BRUSH ASSEMBLY CB - CIRCUIT BREAKER, MAIN OUTPUT GND - GROUND HTO - HIGH TEMPERATURE SWITCH IM- GNITON MODULE LOP - LOW OIL PRESSURE SWITCH SC - STARTER CONTACTOR SCR - STARTER CONTROL RELAY SM - STARTER MOTOR I SP- - SPARK PLUG O- SPLICE LED BOARD O- DISCONNECT SPLICE I I IC 820 1 817 2 L1 818 3 L3 L1: GREEN = SYSTEM READY I I � 819 4 L3: RED = ALARM I I I I 1 I I I I I I I `------------------------- f1 I --------------------P1--------------------------1 L------------------------------------------------------------ ------------------ FUEL 14 OLENOID N7 00 I I I I 1 I I I I I I I BATTERY WARMER I I -14 1 ( DPTIDNAL L---------------------J ED R RFD 13 ----- ---------- -----1 I I 1 I 1 I O I _ NOTE: ALL WIRES 18 AWG 1 I I 300V UL LISTED UNLESS -0 i 12V i SHOWN OTHERWISE I BATTERY i AWG SIZE I I I I CUSTOMER SUPPLIED L----------------------J 21 Electrical Data Electrical Schematic-14kW—Drawing No.OG8513-A ELECTRICAL ~ DATA 2 2 6 6 0 0 VOLTAGE 4 4 q REGULATOR POWER 22 p WINDING 11 11 44 6 STATOR 2233 2 11 POWER BA 0 WINDING 4 0 4 IM2 18 SP2 IM1 18 sP1 i I I' 65 86 l TLOP TO H j 0 56 C ' i i 0 0 I I I 13 ` I. 13 1 13 13 BATTERY 12V i scR T 16 0 sc SM i 22 Electrical Data Electrical Schematic-14kW-Drawing No.OG8513-A ELECTRICAL ~ DATA --► CB 44 � 240 VAC GENERATOR 11 --® ournur 33� NEUTRAL r r r I 22 � 1 I r r I r r r ------------------------------------------------------- I I I I I I 1 I 1 I 240 VAC UTILITY INPUT OPTIONAL BATTERY WARMER N1 N2 N1 N2 85 1 LED BOARD 86 2 J1 13 3 CONTROLLER 820 jlj��18 4 PRINTED CIRCUIT BOARD 817 818 GOVERNOR81 ACTUATOR J3 i J2 1 2 3 4 5 6 7 8 9 10 1112 13 4 14 23 15B 0 6 j 14 82 14 817 818 CS (FS) 819 90 0 0 GROUND 158 + BATTERY 23 i 0 i LEGEND BA - BRUSH ASSEMBLY LOP - LOW ❑IL PRESSURE SWITCH CB - CIRCUIT BREAKER, MAIN OUTPUT SC - STARTER CONTACTOR CS - CHOKE SOLENOID SCR - STARTER CONTROL RELAY FS - FUEL SOLENOID SM - STARTER MOTOR' HTO - HIGH TEMPERATURE SWITCH SP_ - SPARK PLUG IM_ - IGNITION MODULE 23 Electrical Data Wiring Diagram-17kW—Drawing No.OG7948-A 7EELECT7RICAL _ENGINE COMPARTMENT i CONTROL PANE y 2 6 6 z r VOLTAGE a p m 0 0 REGULATOR z z c 4 + 4 I 22 2 ® � 00 i 11 11 TO I 1 1 E 1 i IC IC Z N I � 6 22 2 ffbi 33 I 1 CLOSEST TO BEARING STATOR 44 BA I 0 11 i i I I I I I � I 4 0 I I � I I O I SP1 I I i IM1 18 N1 N2 i I r- i SP2 0 IM2 � i i 85 I 85 1 86 I 86 2 MAIN 13 3 J1 CONTROLLER 18 4 i HTO LOP i i 0 0 T!!!!!, l J3 J2 1 2 3 4 5 6 7 8 9 101112131415161718158 23RED 14 14 81721818 CHOKE gpg 819 i OLENOID i I BLK i 0 i i • I OVERNOR 0 O CTUATO 14 14 I 0 I 0 I 13 16 SM SCR � 13 A 8 13 SC i 0 � 0 p I 13 16 I 0 O 0- 16 i 0 PANEL GND ENGINE GNO FRAME o-0 0 0 GND ra 24 i Electrical Data Wiring Diagram-17kW—Drawing No.OG7948-A EELECTFR17CAL 240V GENERATOR CUSTOMER CONNECT AREA � z < OUTPUT TO TRANSFER D SWITCH CONTACTOR Ir w Z CB 11C Q Q 00 y O O O N M O N M O I I 1 N N i C G 1 1 I 1 I I I�I 44 1 1 11 I I 0 1 ------------------ ----� D O ° O I I 11C 1 � 5 00 00 4- 03 1 I I I 1 I 2 01 I z x 1 M I I I 1 I I I I 1 i LED BOARD I 1 I 820 1 120V/15A 1 817 2 L1 DUPLEX o 0 0 818 3 L3 L1: GREEN = SYSTEM READY LL22 XELLOW = MAINTENANCE REQ'D LEGEND I i 819 4 L3: RED = ALARM BA - BRUSH ASSEMBLY CB - CIRCUIT BREAKER. MAIN OUTPUT I i GND - GROUND HTO - HIGH TEMPERATURE SWITCH 1 I IM- - IGNITON MODULE LOP - LOW OIL PRESSURE SWITCH SC - STARTER CONTACTOR SCR - STARTER CONTROL RELAY SM - STARTER MOTOR SP_ - SPARK PLUG 0- SPLICE Q- DISCONNECT SPLICE 1 IC IL--------------------------------------------- .......................... �{�7 I L-------------------------------------- I I I I FUEL 14 OLENOID I I 1 I I N. 00 I I r---------------t-------1 -14 I 1 I BLACK I I RFD I I I BATTERY 13 0 WARMER ----------------- -------------- I 1 i OPTIONAL I I I I 0 i0+ — 4 —0 I 12V I BATTERY i NOTE: ALL WIRES 18 AWG 300V UL LISTED UNLESS 1 i SHOWN OTHERWISE L--- CUSTOMER-SUPPLIED--- AWG SIZE I -------- ------- � I' 25 Electrical Data Electrical Schematic-17kW—Drawing No.OG8514-A ELECTRICAL F DATA �---- -► 2 2 6 6 0 0 VOLTAGE 4 4 4 REGULATOR 22 22 11 11 :L POWER WINDING 44 6 STATOR 2233 2 11 POWER BA 0 WINDING 4 IM2 18 SP2 6 4 j I i IM1 18 18 SP7 85 86 13 E 5 86 I II I TFITO LOP 0 0 56 j C I 0 0 I I i I' i 13 13 13 13 1 BATTERY- 12V TSCR T I0 SC 13-11 0 SM 26 Electrical Data Electrical Schematic-17kW—Drawing No.OG8514-A ELECTRICAL DATA CB1 /Q- 44 `CY 240 VAC GENERATOR 11 OUTPUT �B2 70-- 33 22 NEUTRAL i ------------------------------------------------ ------00--------/ i 00 i 240 VAC UTILITY INPUT OPTIONAL BATTERY WARMER N1 N2 11C-® 120 VAC 1 N1 N2 00-® ACCESSORY 2POWER 3 J1 CONTROLLER OUTPUT 4 PRINTED CIRCUIT BOARD GOVERNOR ACTUATOR J3 J2 1 2 3 4 5 6 7 8 9 101112131415161718 4 LED BOARD 14 23 1 8 0 6 8201 817 2 818 3 2 81 4 14 817 14 818 CS FS 1 90 p GROUND 15B yy + BATTERY 23 TRANSFER LEGEND BA - BRUSH ASSEMBLY LOP - LOW OIL PRESSURE SWITCH CB-- CIRCUIT BREAKER, MAIN OUTPUT SC - STARTER CONTACTOR CS - CHOKE SOLENOID SCR - STARTER CONTROL RELAY FS - FUEL SOLENOID SM - STARTER MOTOR HT❑ - HIGH TEMPERATURE SWITCH SP- - SPARK PLUG IM- - IGNITION MODULE 27 Electrical Data Wiring Diagram-20kW—Drawing No.OG8186-A CE7LECTRICAL ENGINE COMPARTMENT i CONTROL PANEL x I 2 2 0 z < —�—6 6 VOLTAGE a o 0 0 REGULATOR z z + 22 2 Egib ® ® ® ® 1 11 11 1 I 1 I IC IC z o cv 2 I i I I I I 22 I 2 33 I CLOSEST TO BEARING STATOR 4 BA 4 11 0 I I 1 I I I 4 0 I I I � O 1 0 SP1 ------------------------- -- ------ I I U IM1 18 N1 N2 I I _ 11 2 ll SP2 I I 0 IM2 I I 85 I 85 1 86 I 86 2 J1 AIN CONTROLLER 13 3 I 18 4 HTO LOP I I I J3 0 J2 I 1 2 3 4 5 6 7 8 9 101112131415161718 I 4 I 15B I 23 r---� 820 11 I 1 RED= I 14 I 14 818 2 i 819 CHOKE 90 90 OLENOID ---J I I � BLK 0 K I I I GOVERNOR 0 0 i CTUATO 14 14— I I i I I I O I I I 1 � 16 SM i SCR 13 I � A 8 L 0 56 0 0 0 16 1 I 0 O — ffsl i, 0 PANEL GND ENGINE FRAME O 0 O 0 i 0661 GND 28 Electrical Data Wiring Diagram-20kW—Drawing No.OG8186-A EELECTR17CAL CUSTOMER CONNECT AREA o 240V GENERATOR Z a OUTPUT TO TRANSFER o SWITCH CONTACTOR z CH 11C O 00 O O O N M O N M O I I 1 I I I I I _a I 1 I 44 I I 0 p 0 ------------------ ----- 11C I ' 1 ' 5 1 00 00 A 03 I ' I I I I I 21 I I I ' I ' I ' LED BOARD 120V/15A 1 812 1 DUPLEX O 1 817 2JJ3 O 0 O 818 3L1: GREEN = SYSTEM READY 194 Lj. YELLOW = MAINTENANCE REQ'D LEGEND I I L R DD = ALARM BA - BRUSH ASSEMBLY CB - CIRCUIT BREAKER, MAIN OUTPUT I 1 GND - GROUND HTO - HIGH TEMPERATURE SWITCH IM- - IGNITON MODULE I i LOP - LOW OIL PRESSURE SWITCH ' I SC - STARTER CONTACTOR SCR - STARTER CONTROL RELAY II SM - STARTER MOTOR SP- - SPARK PLUG Q- SPLICE 1 - DISCONNECT SPLICE I IC L------------------------------------------------------------- ------------------I FUEL ' 14 OLENOID I I I I -14 0 N1 00 BLACK 1 I 1 I I RED I I 0 13 i BATTERY - ---------- ---- -----� i WARMER I I I I I I I 1 0 i + — i OPTIONAL 1 I ____________J —0 12V I BATTERY 1 NOTE: ALL WIRES 18 AWG CUSTOMER SUPPLIED i 300V UL LISTED UNLESS SHOWN OTHERWISE AWG SIZE 29 Electrical Data Electrical Schematic-20kW—Drawing No.OG8515-A ELECTRICAL ~ DATA 2 2 6 6 0 0 VOLTAGE 4 4 REGULATOR 22 2 11 11 POWER WINDING 44 STATOR 2233 . 6 2 11 POWER WINDING BA 4 IM2 18 SP2 0 4 IM1 18 18 SP7 85 86 13 85 86 1 ?TOLOP 56 0 C 0 p �-13 13 13 1 13 BATTERY= 12V - S S0 16 SC 13 SM " 30 Electrical Data Electrical Schematic-20kW—Drawing No.OG8515-A ELECTRICAL ~ DATA -► -� CB1 �/Q 44 `CY 240 VAC GENERATOR 11 OUTPUT 2 /J� 33 22 NEUTRAL r ----------------------------------------------- ------00--------/ i 00 i i 240 VAC UTILITY INPUT OPTIONAL BATTERY WARMER Ni N2 11C ® 120 VAC 1 �N1 N2 00 ACCESSORY 2 POWER 3 J1 CONTROLLER OUTPUT 4 PRINTED CIRCUIT BOARD GOVERNOR ACTUATOR J3 J2 1121314151617 8 9 10 11 12 1314 15 16 17 18 LED BOARD 4 14 23 1 B 6 820 1 817 2 J I 818 3 82 81 4 14 817 14 818 CS fS B19 0 & GROUND 90 0 15B + BATTERY 23 LEGEND BA - BRUSH ASSEMBLY CB_ - CIRCUIT BREAKER OUTPUT LOP - LOW OIL PRESSURE SWITCH CS - CHOKE SOLENOID SC - STARTER CONTACTOR FS - FUEL SOLENOID SCR - STARTER CONTROL RELAY HTO - HIGH TEMPERATURE SWITCH SM - STARTER MOTOR IM_ - IGNITION MODULE SP- - SPARK PLUG 31