Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
37689-Z
$�FFa�u- Town of Southold Annex 12/3/2013 P.O.Box 1179 c cm54375 Main Road x o Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 36630 Date: 12/3/2013 THIS CERTIFIES that the building SINGLE FAMILY DWELLING Location of Property: 500 KERWIN BLVD GREENPORT, SCTM#: 473889 Sec/Block/Lot: 53.-4-44.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 9/25/2009 pursuant to which Building Permit No. 37689 dated 12/14/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: A NEW ONE FAMILY DWELLING(MODULAR), WITH COVERED FRONT PORCH,REAR DECK AND ATTACHED TWO CAR GARAGE AS APPLIED FOR The certificate is issued to JAMES POSILLICO (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL R10-06-0689 10-08-2013 ELECTRICAL CERTIFICATE NO. 4509 08-30-2007 PLUMBERS CERTIFICATION DATED 09-25-2013 Van EtWgPlumbing&Heating Auth d S atur ��4yoS�F TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN CLERK'S OFFICE o • SOUTHOLD, NY BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 37689 Date: 12/14/2012 Permission is hereby granted to: JAMES POSILLICO 346 MAPLE AVENUE STE-12 WESTBURY, NY 11590-3252 To: CONSTRUCTION OF A NEW ONE FAMILY DWELLING (MODULAR) W/ATTACHED TWO CAR GARAGE, COV FRONT PORCH & REAR DECK AS APPLIED FOR. REPLACES EXPIRED B.P. # 35029 At premises located at: 500 KERWIN BLVD GREENPORT SCTM # 473889 Sec/Block/Lot# 53.4-44.1 Pursuant to application dated 9/25/2009 and approved by the Building Inspector. To expire on 6/14/2014. Fees: PERMIT RENEWAL $1,222.40 CO -NEW DWELLING $50.00 Total: $1,272.40 Building Inspector FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) PERMIT NO_ 35029 Z Date SEPTEMBER 25, 2009 Permission is hereby granted to: JAMES POSILLICO 31 TENNYSON AVE WESTBURY,NY 11590 for CONSTRUCTION OF A NEW ONE FAMILY DWELLING (MODULAR) W/ATTACHED TWO CAR GARAGE, COV FRONT PORCH & REAR DECK AS APPLIED FOR. REPLACES 32668 . at premises located at 500 KERWIN BLVD GREENPORT County Tax Map No. 473889 Section 053 Block 0004 Lot No. 044 . 001 pursuant to application dated SEPTEMBER 25, 2009 and approved by the Building Inspector to expire on MARCH 25, 2011. Fee $ 2, 444 . 80 Authorized Signature ORIGINAL Rev. 5/8/02 FORM NO. 3 TOWN OF SOUTHOLD BUILDING DEPARTMENT Town Hall Southold, N.Y. BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) 3,-0 2-p PERMIT NO. 32 Z Date JANUARY 24, 2007 Permission is hereby granted to: POSILLICO CONST. 31 TENNYSON AVE WESTBURY,NY 11590 for CONSTRUCTION OF A NEW SINGLE FAMILY DWELLING (MODULAR) WITH ATTACHED TWO CAR GARAGE, COVERED FRONT PORCH & REAR DECK AS APPLIED FOR at premises located at 500 KERWIN BLVD GREENPORT County Tax Map No. 473889 Section 053 Block 0004 Lot No. 044 . 001 pursuant to application dated JANUARY 5, 2007 and approved by the Building Inspector to expire on JULY 24 , 2008 . Fee $ 2 , 444 . 80 Authorized Signature COPY Rev. 5/8/02 Form No,6 TOWN OF SOUTHOLD BUILDING DEPARTMENT • TOWN HALL 765-1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: l. Final survey of property with accurate location of all buildings, property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal(S-9 form). 3. Approval of electrical installation from Board of Fire Underwriters. 4. Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from architect or engineer responsible for the building. 6. Submit Planning Board Approval of completed site plan requirements. B. For existing buildings(prior to April 9, 1957)non-conforming uses,or buildings and "pre-existing" land uses: 1. Accurate survey of property showing all property lines,streets, building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied, the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees I. Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00; Alterations to dwelling$50"00, Swimming pool $50.00, Accessory building$50.00,Additions to accessory building$50.00, Businesses $50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy - $50.00 5. Temporary Certificate of Occupancy- Residential $15.00, Commercial $15.00 Date. h 2 New Construction: Old or Pre-existing Building: (check one) Location of Property: �O D f(-evwn-► FrV� P�� House No. Street Hai let Owner or Owners of Property: �DS�II/Zois�yyt��j�, �pc Suffolk County Tax Map No 1000, Section 5r 3 Block . Lot Subdivision Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board Approval: Request for: Temporary Certificate Final Certificate: (check one) Fee Submitted: $ v� Applican ign tune .�.ng K!'a 7' .3T"' gp-.:5[S�F <?"?: mr< ;#- :;R. '�it'ff ;m-�,'ttJ+' . _F�+ �4' s ;'[ :'$£:'�' y� s.`9c;�y"#.". G m.fi}[? MR-ME'. E' RR ^MR-K r.i4>xz so u Sp &++ 5 a s 4w� art {� -. I, 2 ? f �rR h,yy s d�i� 2 �h.�,1:,2�.5:.��.+.�...,..,<...tw..._„+i�:l�]4:;.`�.#�� ,:.{'*4u':if.e4'3.R.t4:.i._'��„i'res3[�..=3�a..�..._cety�...l'...:�1:3°eS:a � .ish�3ki1�",�`' a+Y�[?ftf._,...i., a'.€..LC" .�3`4 c:...<��....Ll�"���":F-»..,iar� i.. �...b + ` ' SUFFOLK BUREAU of ELECTRICAL. �4 I N S P E C T O R S, i n c. {``pp tt� Via^; 40 Nottingham Drive, Middle Island, NY 11953 Telephone: 631-495 8136 ■ Fax: 631 980 6455 ■ E-Mail: SBEIGS@gmaii.com N MA CERTIFICATE OF ELECTRICAL COMPLIANCEk �', ?;Applicant: R.C. Electric Corp. Rough In Inspection Date: 8/29/2007 Final Inspection Date: 8/29/2007 s, ' °• Certificate NO: 4509 Application NO: 4509Y IY; ,�5+ Suffolk County Tax Map NO: 53 4 44.1 Building Permit N°:.,This Certificate of Electrical Compliance is limited to the inspection and compliance of electrical equipment > and/or work described below, installed by the applicant named above, located at the premise of and not ? [ after the final inspection date above: G Q Owner: Posillico Construction Co. Inc. >; Address: 500 Kerwin Blvd., Greenport, NY 11944 +iAddress of Inspection Site: 500 Kerwin Blvd., Greenport, NY 11944 {i u X Residential X Indoors Basement X Service Shed s Commercial X Outdoors Ist Floor Pool X Other: .t" X New Renovation 2nd Floor Hot tub Modular Home " 1 T Addition Survey Attic Garage ' f Inventory 200 UG Service 1Qj Oil Heat Duplex Recpt Ceiling Fix HID Fix -' }' Service 30 Time Clock 2 Switches Wall Fix 1 Smoke Det 3 20 Ckt Main Panel Oil Hot Water 1 GFCI Recpt Recessed Fix Co Det ' u k; V Sub- Panel GFCI Breaker Single Recpt Fluorescent Fix Pump 2 Disconnects Dryer Recpt Range Recpt 2 A/C Blower Emergency Fix Transformers Exhaust Fan Appliance 2 A/C Cond Exit Fix3 'Twist Lock TVSS Heat Pump Electric Heat Pool Luminaire a Other Equipment: New York State Ingignia of Approval Num. 1940823, DoM 3/20/2007 k Plan Approval Num. M0319-02-055, Serial Num. 9883 ' The electrical work and/or equipment described above were inspected and appear to be in compliance with ± local, state and national electrical code requirements and this office. ;Applicant: R.C. Electric Corp. License No: 1610-MEW. rP, IN ;Inspected by: a Surdi Date of Certificate: 8/30/2007 W 3 Signature: 64'[y eSFi fi �f".7�.�*�m".gk'a" �2z..;._�-ra µ<Y.�s r'*s� ,fi �,:.. 7�,.sr,�.�••a2:�[�T�-<.�r�,st r y REEVE,�''n .9"' '�^ri,fi t^F.3 [+'.�'S"+^�'3.�, 19 .." a 5 4i ! N E �` M tF,�- > R—Ra"M ' ... �n� 3. x 4�i.M�,' �1�.:'�*'�„�.t�.�u!�.:Y.�m...SI�Y�� '..a:.�az"�fh„.�x�`�.t: :J��:�,��:���,,,r�>� ._..v:_...� t�S..'�L �� f:&� r� Suf����Cp o CM = Town Hall,53095 Main Road $ P.O..Box 1179 Fax(631) 765-9502 Southold, Nev., York 11971-0959 Telephone(631)765-1802 BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATION Date: ����51, > Building Permit No. Owner: ✓CLA f >n (Please print) Plumber: P nEHCY1 ��(I Mh Cr #e"'v)q (Please prin I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. (.Plumbers Signature) sNvoin to before,me this -,C� day of , 20 /L.? Notary Public, County CHRISTIE HALLOCit . Notary Public, State of New York No.4831950,Suffolk County Ohmission Expires May 31.,2 A� Of SoUryo coUNi`1,� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ FOUNDATION 1 ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION R ARKS: 8-. - i Af o / DATE °� INSPECTOR '`� �pF SOUIy �o� ono TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] F DATION 1 ST [ ] ROUGH PLBG. [ FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR i OE SOUjy�l � o cou TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ ] FOUNDATION 2ND [ ] INSULATION [ FRAMING STRAPPING [ ] FINAL [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: � '� V�' dalclL DATE 7—.5- o 7 INSPECTOR ' OF SO(/T�OIo 35o ;2- UM`1,0c� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PL13G. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING / STRAPPING [�']f FINAL [ ] FIREPLACE A CHIMNEY �[ �] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION REMARKS: DATE INSPECTOR 3.7 of SOplyo �o Comm, TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] IN A [ ] FRAMING /STRAPPING [ FIN [ ] FIREPLACE & CHIMNEY [ ] FIRE SA Y INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: 4 /Jo /,;,Jcj-t'), \ DATE G INSPECTOR S ECTOR Go F�� o��q SOUTy� H O cou TOWN OF SOUTHOLD BUILDING.DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INS TION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) 7 - REMARKS: C DATE ` ® INSPECTOR aoF souls — oouM'1,a`� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INS LATI . [ ] FRAMING /STRAPPING [ FIN [ ] FIREPLACE & CHIMNEY [ ] FIRE Y INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE / l INSPECTOR �� FIELD INSPECTION REPORT DATE COMMENTS ' FOUNDATION(IST) LHit i -------------------------------------- FOUNDATION (2ND) ~� z � . y ROUGH FRAMING& PLUMBING Coo t-' INSULATION PER N.Y. j STATE ENERGY CODE FINAL 04 ADDITIONAL COMMENTS < �f ig 4 I ,Y �^ A Y U' l� C x d � d d b TOWN OF SOUTHOLDI r,:' l BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL I�' Board of Health SOUTHOLD,NY 119711 ` __. j 4 sets of Building Plans TEL: (631) 765-1802 -t s - j�SCGJ��i1 Planning Board approval FAX: (631) 765-9502 - ` I Survey www. northfork.net/Southold/ PERMIT NO. - �� Check \ Septic Form N.Y.S.D.E.C. Trustees Examined ,20A27 Contact: Approved ,20 Mail to: 76)I.i/ F0 Disapproved a/c Phone: 516 2-SD " y7S1 Expiration ,20 10 Building Inspector APPLICATION FOR BUILDING PERMIT Date );�V\ww J , 20 67 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises,relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d.Upon approval of this application,the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If no zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may authorize, in writing,the extension of the permit for an addition six months.Thereafter, a new permit shall be required. APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described.The applicant agrees to comply with all applicable laws, ordinances,building code,housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) zG s �St Ave - Su; ass (Mailing�a/ddress of applicant) VVPSi��2 1 A/( 1/SJ0 State whether applicant is owner, lessee, agent, architect, engineer, general contra or, electrician, plumber or builder wmP Name of owner of premises (As on the tax roll or latest deed) If applic is a c rpora , sigp3Wre f duly authorized officer '(Name.aPdtiffe of corporate fficer) Builders License No. Plumbers License No. elea A �;d Electricians License No. era f -k b; Other Trade's License No. 1. Location of land on which proposed work will be done: -500 `('eV, House Number Street Ham et County Tax Map No. 1000 Section 3 Block � ''' ''Lot. Filed Map No. ,.> Lot , (Name) 2. State existing use and occupancy of premises and intended use and occupancy;l, proposed construction: a. Existing use and occupancy //aCeiy b. Intended use and occupancy 3. Nature of work (check which applicable): New Building ✓ Addition Alteration Repair Removal Demolition Other Work (Description) 4. Estimated Cost ���J,�IrD Fee (To be paid on filing this application) 5. If dwelling, number of dwelling units Number of dwelling units on each floor If garage, number of cars Z 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. 7. Dimensions of existing structures, if any: Front Rear Depth Height Number of Stories_ Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front �7/ _ Rear -7/ -6 Depth -o Height 2q/ Number of Stories 2 9. Size of lot: Front 972 , 2 Z Rear. 612V, S& Depth 110S•66 10. Date of Purchase dv/o' 5 Name of Former Owner ? 11. Zone or use district in which premises are situated R- go 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO c� 13. Will lot be re-graded? YES ✓ NO Will excess fill be removed from premises? YES NO / 26s Pa-f At,e- Sui4 355" 14. Names of Owner of premises Ps;llr,.4 si '61 7r,Address j&ys F6 t.,r bV I I s 0 Phone No.S/G-333-ogo Name of Architect -3Ay-.4-r 07,444-�- Address sio etip,�j5`ivV Phone No 63/-2oA,-8860 Name of Contractor 415 DW,A Address 5,,me .r Phone No. S16 333 oG66 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO ✓ * IF YES, SOUTHOLD TOWN TRUSTEES &D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. STATE OF NEW YORK) SS: COUNTY OF�j jnj tc�) being duly sworn, deposes and says that(s)he is the applicant (Name of indi idual signing contract) above named, (S)He is the ®6v Al�r' ✓ (Contractor, Agent, Corporate Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Swe -.ri,to before me this_ -C� � day of 20� Notary Public Si re of App icant MELANIE DOROSKI NOTARY PUBLIC,State of New York No.01D04634870 Qualified in Suffolk County i' Commission Expires September 30_1W New York State Department of Environmental Conservation Division of Environmental Permits, Region One SUNY @ Stony Brook, 50 Circle Road, Stony Brook, NY 11790 -3409 - Phone: (631)444-0403 • FAX: (631)444-0360 Website: www.dec.state.ny.us Denise M.Sheehan Commissioner Letter of Non-Jurisdiction - Freshwater and Tidal Wetlands Acts November 30, 2006 Posillico Construction Co., Inc. 265 Post Avenue - STE 355 Westbury, NY 11590 Re: Posillico Construction Company Property s/w c/o Kerwin Blvd & LIRR Greenport, NY 11944 SCTM# 1000-53-04-44.1 DEC# 1-4738-03596/00001 Dear Posillico Construction Company:: The Department of Environmental Conservation has completed its review of your proposal to subdivide a 7.73 acre parcel located in the vicinity of state regulated tidal wetlands and freshwater wetlands into four lots and construct a single family dwelling with,septic system on each lot. The,site;is located.on the west side of.Kerwin;Blvd. just south of-the Long.Island Railroad,rig ht-of-way in Greenport. The entire property (Parcels 1, 2, 3 &4) is:located,Jandward of a functional and substantial man-made structure (a paved road), which is greater than 100' in length and was constructed prior to 8/20/77..as shown on NYDEC's Tidal Wetlands Aerial Photomap #718-550;and is therefore beyond the jurisdiction of Article 25 (Tidal Wetlands). Therefore, in accordance with the current Tidal Wetlands Land Use Regulations (6NYCRR Part 661) no permit is required under the Tidal Wetlands Act . Please be advised that the subdivision of land is not regulated under the Freshwater Wetlands Act. Parcels 1 &2 of the proposed subdivision at the property referenced above, are more than 100 feet from regulated freshwater wetlands. Therefore, no permit is required under the Freshwater Wetlands Act (Article 24 of the Environmental Conservation Law) for activities on these parcels. Your proposed projects,to construct single family dwellings on Parcels 3&4 of the proposed subdivision as shown on the survey prepared_by Jeffrey T. Butler last revised October 19, 2006, are more than 100 feet.from regulated freshwater wetlands. Therefore, n.o.permit is required under the Freshwater Wetlands Act ((Article 24 of the Environmental Conservation Law)._ Be advised that.all construction, clearing,,and/or ground disturbance must remain more than 100 feet from the freshwater wetland boundary. It is your responsibility to ensure that all necessary.precautions are taken to prevent any sedimentation or other alteration or disturbance to the ground surface or vegetation within Freshwater and Tidal Wetlands jurisdiction which may result from your project. Such precautions may include erecting a temporary fence, barrier, or hay bale berm. Please be further advised that this letter does not-relieve you of the responsibility of obtaining any. necessary permits or approvals from other agencies. Sincerely, �i George W. Hammarth Permit Administrator 544 cc: Jeffrey T. Butler BOH MHP file 1 i POSILL ICO CONSTRUCTION COv�j INC. 265 Post Avenue • Suite 355 • Westbury,NY 11590 516-333-0666 • Fax 516-333-6903 TRANSMITTAL Dat* i�//�Sf 0 7 _ Tod- 7�-t�lcS Address -S 30 9s Attention: f f d, Oa X 117 q 5rn.1 We are sending herewith CONTRACT tRINTS As follows: / ����se� ��-e s���ne d re✓r sr c,..s (3 ems-;ems, �`� V el 774`Y en Gi l�P 2tr c AG1n!�P c -r11-e- rar-) n -4 c'ios-e Y aivl� CIAA4 Pd y ecesse� 41 h/-f - 17 jAN jr Yours truly, Received POSILLICO CONSTRUCTION CO.. INC. I By By SOUjyolo Town Hall Annex Telephone(631)765-1802 54375 Main Road Fax(631)765-9502 Cori P.O.Box 1179 G �OQ Southold,New York 11971-0959 �� BUILDING DEPARTMENT TOWN OF SOUTHOLD Posillico Construction Co., Inc 265 Post Avenue Suite 355 Westbury, NY 11590 July 1, 2009 Re: 500 Kerwin Blvd., Greenport SCTM# 1000-53.4-44.1 Violation To Whom This May Concern: Your expired building permit (#32668) for construction of a single family dwelling, has been referred to my office. Pursuant to 144-15A., of the Southold Town Code, "No building hereafter erected shall be used or occupied in whole or in part until a certificate of occupancy shall have been issued by the Building Inspector." Your building has not had all of its required inspections, does not have a certificate of occupancy, and there is evidence that the home is currently occupied. Therefore, you have ten days from the receipt of this letter to contact this office, at(631) 7654802,between the hours of 8:00 a.m. and 4:00 p.m., and clear up this matter or legal action will be taken against you. Qaz , Inspector Depa ent 696 fi gTEL 2p O D❑ pSTE, S❑�L `✓ z�'�} f OgUFFOt,t Southold Town Building Department ' 54375 Main Road Permit#: 35029 Southold,New York 11971 Permit Date: 9/25/2009 -V (631)765-1802 y�jpl ,�aoa�` Expiration Date: 3/25/2011 Parcel ID: 53.4-44.1 BUILDING PERMIT RENEWAL LETTER Dated: 11/7/2011 Applicant: JAMES POSILLICO Location: 500 KERWIN BLVD GREENPORT Work Description: SINGLE FAMILY DWELLING CONSTRUCTION OF A NEW ONE FAMILY DWELLING (MODULAR)W/ATTACHED TWO CAR GARAGE, COV FRONT PORCH&REAR DECK AS APPLIED FOR. REPLACES 32668. A FEE OF $1222.40 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Owner: JAMES POSILLICO Address: 346 MAPLE AVENUE STE-12 WESTBURY,NY 11590 The permit listed above has expired. Please contact our office as soon as possible to begin the renewal process. All work on the project must stop on the expiration date. No work is permitted or authorized beyond the expiration date. THANK YOU, SOUTHOLD TOWN BUILDING DEPT. Y Southold Town Building Department SQfFOt,��o` P.O.Box 1179 54375 Main Road Permit#: 35029 c + Southold,New York 11971 Permit Date: 9/25/2009 (631)765-1802 P Parcel ID: 53.4-44.1 Expiration Date: 3/25/2011 BUILDING PERMIT RENEWAL LETTER FINAL NOTICE Dated: 8/6/2012 Applicant: JAMES POSILLICO Location: 500 KERWIN BLVD GREENPORT Work Description: SINGLE FAMILY DWELLING CONSTRUCTION OF A NEW ONE FAMILY DWELLING (MODULAR) W/ATTACHED TWO CAR GARAGE, COV FRONT PORCH & REAR DECK AS APPLIED FOR. REPLACES 32668. A FEE OF $1222.40 IS REQUIRED TO RENEW THIS BUILDING PERMIT. Owner: JAMES P05ILLICO Address: 346 MAPLE AVENUE 5TE-12 (� WESTBURY, NY 11590 The permit listed above has expired. Please contact our office as soon as possible to begin the renewal process. All .work on the project must stop on the expiration date. 3 THANK YOU, SOUTHOLD TOWN BUILDING DEPT. r Southold Town Building Department ��oasUEFO(��,Gg.+ P.O.Box 1179 Permit#: 35029 .� 54375 Main Road W Southold,New York 11971 Permit Date: 9/25/2009 .40o� (631)765-1802 Expiration Date: 3/25/2011 Parcel ID: 53.-4-44.1 Dated: 12/4/2012 Applicant: JAMES POSILLICO Location: 500 KERWIN BLVD GREENPORT Work Description: SINGLE FAMILY DWELLING CONSTRUCTION OF A NEW ONE FAMILY DWELLING(MODULAR)W/ATTACHED TWO CAR GARAGE, COV FRONT PORCH&REAR DECK AS APPLIED FOR. REPLACES 32668. Owner: JAMES POSILLICO Address: 346 MAPLE AVENUE STE-12 WESTBURY, NY 11590-3252 Your BUILDING PERMIT #35029 has been referred to me because you have not responded to requests to obtain your Certificate of Occupancy as required by Southold Town code. Pursuant to 144-15A, of the Southold Town Code, "No building hereafter erected shall be used or occupied in whole or in part until a certificate of occupancy shall have been issued by the Building Inspector." Therefore, you have ten days from the receipt fo this letter to submit a check made out to the Town of Southold in the amount of$1272.40 to renew the building permit, or legal action will be taken against you. Should you have any questions, call the building department between the hours of 8:00 a.m. and 4:00 p.m. Respectfully Yours, 7011 1570 0001 8894 8879 9*4-16AL4%4 Michael Verity: Chief Suilding Inspector Southold Building Department cc: Damon Rallis Zoning Inspector t i { d • * Cf ` } t i * 1 R said ,r `.F 1 � flit � A � 9a $ ,aid,};3' rry 5 , 111 J� 9p S +V`:'. �1 P rya + � ���'. •.. r _, -,"A�'A r _a f► �� �� a k n Ix cl:iul� p I ri I� � ------------- 5t� — ------------- I W N V1 • � �` j t _1_ vt� I -- I kj L-------- --- -- -- — ------- t 6 ,V + 1N24P o z c cs� o a 12'�' W-0' _ W-0' H m- rn to rst m 24'-0' W-0' �. _ Imrn . m 79 cm x-v ti r-O rd c� •i x C 'Q r= SGttt li CUMMER HAMS, 4 1 /4 H-0Ur Mih,'ME SvrtT t �� ' ?r, f 4, FROMM STERN RESIDENCE i c 0!—[,5-05 r 1 i64 KERWI N 6LYR 4 SLI�I,�` Il ��rwvra �r REE GNi'ORT, Hy ROA 0 P4 BOX 118 BEECH CREEK, PA 16 922 (570) 962-21LI (370) 962-3181 (FAX} SHEET ` � ... , .� 51;cr.44P FLOOD, PL � �d: ._r.: �: ,.,,, I'OSll.LICO CONSTRUCTION o - ----------------,----------- - ��II � _.�..--._ ---._____.._ a [ • I I r ——— II u I I I �1 ni I ---J � w w N Gil C� Cu8fo p' NAMEi RAY 1 S 1 ON5 BET 5TERK TE THENCE PATE -- — - -' -- - -- _ JC6 i� 2�F-�- 8 -- ADD REC LIGNtS r� J�;s f MTOMEK 7tiDOXM3 t � ,,.�,e-�°��,, ,�•�I' �. Dpl III TWO ' - �ECP /�DDEP C iR:L'AY13Urt - - - � -=,�� `�' ; � 4Et4 KERWIH6LY� . ..... _..-•--•--- -- JC6 �1-93-07• ----' Y�1iI�LPQOI_Si�ItCf{E6_ o EAGLE TALI, ROAD DRAWN sr I ORESNPORT, NY 5UII,DER, 17a BEECH CREEK, PA 16822 DRAM NG L1 (570) 'W-3191 (PAX} C4=64 _. .._. — -BUC7 1 - pQ 1. ,1Q L CQNSTRUGT I QN R&S.TAVARES ASSOCIATES 3324 SANTA'FE STREET TEL: (209) 863 8928 RIVERBANK, CA 95367 =VARES FAX: (209)863 8952 �xas a rit��s Gnr i :26.6 qnz=`28.2 MWRFS Loads GCpf GCpi GCpf-GCpi .Pi. pZ ELV.=15' ELV.=23' Wind.Perpendicular to-Ridge (CASE A) Windward Roof INT 0 21 0'18 0 39 ;. e xT EXT 0 27.. 0 18 0 45;. - 1100 �. .���� 12:69 Leeward Roof ziNT -0.43 0.18 -0.61 -17.20 EXT 0 53 0.18 -0 71 20 02 - Windward Wall "INT 0 56 0 18 ;0 74 19a68P= Xf 0 69 8.4 0 87 - .Leeward Wall INT 0.37_ 0.18 -0.55. -14.63 EXT -0.48 0.18 0.66_- -17.56 MWRFS Loads GCpf GCpf GCpf-GCpi P1 pz ELV. 1 5'j ELV.=23' Wind Parallel to Ridge (CASE B) Roof 2 :: fNT =0 69 -24:53 E, 1 07 0 18 35.25 Roof 3 INT -0.37 ... 0.18 -0.55 -15.51 EXT -0 53 0 18 -0.71 -20 02 Wa II 1 INT -0 45 0.1.8 =0;6.3 16.:76 , XT '0 48 0 1.. E �. ; . 8 -0 66 � -17 56 Wall 4 INT -0 45 0.18 -0.63 -16.76 EXT 0 48 0.18 -0 66 -17.56 Windward Wall, INT 1543 16,36 Zi EXT 0 61 0 18 <0 79 Leeward Wall INT -0.29 .0.18 -0.47 -12.50 -13 55 EXT -0.43 0.18 -0.61 -16.23 -17.20 NOTE 1) AVERAGE'OF INT&EXT IS USED: PLEASE REFER TO DIAGRAM OF PAGE 43 OFASCE 7-98 FOR BUILDING SURFACE DESIGNATION R : HAVEN HOMES STRUCTURAL CALCULATIONS . Sheet 3 of HOMES (Stern Residence, , Greenport, NY) . R&S TAVARES ASSOCIATES. .- TEL: (209)863.8928. 3324 SANTA FE.STREET " RIVERBANK, CA,95367 ,' BARES FAX: (209)863 8952 :. 4?C`[rYFPS DISTRIBUTION OF WIND INTO MAIN BUILDING'S SURFACE ROOF PITCH 9112. Case A 11.84 psf 18.61 psf 9,9g Psf 14.89psf 7.11 psf. 11.17 psf . 27.6 21.41 psf P 16.09psf q 21 l psf 09 psf .. WIND.PERPENDICULARTO RIDGE `Case B . 29.89 sf P 17.77 psf - 14.21 psf 23:91 psf 17 94psf 10.66:psf 2T_6".. 17 16 psf 1 7.16 psf 17.16 psf,., 11.16 psf 19.32 psf 15.23 psf 18.22 sf .36 psf p - 14 WIND PARALLEL.TO RIDGE I ; . i RSTA#6291 STRUCTURAL.CALCULATIONS Sheet 4 of HAVEN HOMES. (Stern Residence, Greenport, NY) R&S TAVARES ASSOCIATES ► 3324 SANTA FE STREET FAX (209) 863 8952 RIVERBANK, CA 95367 AVARES � DISTRIBUTION OF WIND INTO BUILDING PART 1 UILDING - .:�, PART 1 ..: . 34'-0- BUILDIN PART2 20'-0" -:BUILDDID .. .. _ .. PARTS .. Uplift Uplift V_RF_L=308 PLF " V_RF T=339 PLF: V_FLR2_L=310 PLF V_FLR2_T=3561'L \� 1' 7 6^ 27-6• V_FLRI—L=170'PLF F 4a D^ V_FLRI_T=206 PLF. TRANSVERSE DIRECTION " LONGITUDINAL DIRECTION TRANVERSE.SHEAR(IN 27'-6" DIRECTION) v — 711 + 11,17 r 2751 RF T — ( )'I 2 _2 J + (21.41 + 16.09) plf.. VFLR2 T:_ (21.41.+ 16.09).12 +2 +.1 vFLR2_T=356 plf r . VFLRI T (21.41 + 16.09) 12 + 1) - �FLRI T=206 plf l � . LONGITUDINAL SHEAR(IN 44'-0"'DIRECTION) vRF L = (19.32+ 15.23) I 9 22.51 � + (18.22+ 14.36)•8 v L=308 plf 2 _ vFLR2 L —: (18:22+ 14.36)• 8 +.9 + 1 C2 2 vFLR2 L =310 plf vFLRl_L. (18.22+.1.4.36). + 11:. . vFLRl L= 179 plf UPLIFT 23.91 + 14.21 Uplift:= AVERAGE UPLIFT 2 Uplift=.19 psf RSTA#6291 STRUCTURAL CALCULATIONS Sheet 5 of HAVEN HOMES (Stern Residence, Greenport, NY) R&S TAVARES ASSOCIATES TEL: (209) 863-8928 - 3324 SANTA FE"STREET m AARES FAX: (209) 863 8952 : RIVERBANK, CA 95367 . , 8�1+IA:rls DISTRIBUTION OF WIND INTO BUILDING PART . I _ -------_---- w. UILDING A w _ PART 1 34'-0" �. ..2T-6'• 'BUILDIN PART 2• 8_0, 20- 0" BUILDING PART Uplift - Uplift,.. V_RF_L=364 PLF .,V RF T=402 PLF 34' V_FLRI T 206 PLF - - :V_FLRI-L=179 PLF 27_6- -. TRANSVERSE DIRECTION" LONGITUDINAL DIRECTION- TRANVERSE SHEAR( IN'34'-0" DIRECTION) vRF T2 (7.11 + 11.1 T) 9 :( 9. 341 + (21 41 + 16.09) 402 plf „ 12. 2 J . 2 RF T2 vFLRI T2=.(21.4 2 1 + 16.09) � + 1l �FLR1_T2=206 plf LONGITUDINAL SHEAR(IN 27'-6" DIRECTION) V RF L2 (19.32+ 15.23).. •2 1•�.+ (18.22+ 14.36) 8 v 364 plf (72 J 2 —L2 VFLR1_L2': (18.22+ 14.36) �9.+ IJ 2 , �FLRl. L2= 179 plf UPLIFT U lift 23.91 + 14.21 P = 2 AVERAGE UPLIFT Uplift= 19 psf RSTA#6291 STRUCTURAL CALCULATIONS Sheet 6 of HAVEN HOMES (Stern Residence, Greenport, NY) -R&S TAVARES ASSOCIATES TEL (209) 863 8928 L .3324 SANTA FE STREET FAX: (209) 863 8952 RIVERBANK, CA 95367. y AVs1RE3 �� DISTRIBUTION OF WIND INTO BUILDING PART 3 -------- - i BUILDING 3.4'-0' BUILDIN PART 2 44'0"` - 20.0" BUILDING.. PART Uplift Uplift V_RF_L=260 PLF 2V ' 'V_FLRI_T=206PLF V_FLRI_L=1:79 PI F 20•-0° TRANSVERSE DIRECTION LONGITUDINAL DIRECTION TRANVERSE SHEAR( IN 20'-0" DIRECTION) r 9 20 VRF T3 (7.11 + 11.17) 112 2 ) + (21 41 + 16.09).� vRF 306 plf VFLRI T3 (21.41 +. 16.09) 9 + 1 (2 l vFLRl T3 -206 plf LONGITUDINAL SHEAR(IN 8'-0" DIRECTION) 12 vRF•L3 := (19.32+ 15.23) • 01•� + (18:22+ 14.M) 2 vRF L3 =260 plf VFLRI = 18.22+ 14.36 9 i - (2 ). vFLRI_L3 = 179 plf. UPLIFT U lift 23.91 + 14.21 P 2 AVERAGE UPLIFT Uplift= 19 psf RSTA#6291 STRUCTURAL CALCULATIONS Sheet 7 of HAVEN HOMES (Stern Residence, Greenport, NY) i it R&S TAVARES ASSOCIATES TEL: (209)863-8928 ` 3324.SANTA FE STREET FAX: (209)863.8952 RIVERBANK.CA 95367 kS; TIES ALLOWABLE DIAPHRAGM DESIGN-VALUES ROOF'DIAPHRAGMS 5/32'.' CDX.OR OSB(2410-EXP1)-USE PLY CLIPS @ PLY PANEL EDGES AILING SHALL BE,Sd @.6`E N ;&.12" F.N. OR R 7/16"x2'1x16Ga'Sta le 4 p - @ .E.N.'&. _.8" F.N. LLOWABLE SHEAR= 165"1iO4/3=308 PLF or`165*1.4=231 PLF i VALLOW RF T 30 Plf VALLOW RF L . 231 plf FLOOR DIAPHRAGMS::.: '. 12":PLY OVER.7/16 PLY., CDX OR OSB (24/0-:EXP1) ,T&G EDGES, OP PLY NAILING SHALLBE 7d @ 6" E.N.,&:12".F.N. OR EQUIV. BOTTOM.PLY;NAILING.SHALL,BE 10d @ 6" E.N.,& 12"F.N. OR 7/16"x2"x16Ga Staple @ 4"E.N.,& 8•: F.N. : LLOWABLE SHEAR 200*1.4*4/3=372 PLF or(200*1.4=280-PLF) VALLOW_FLR T:-,377 Plf VALLOW RLR L 28 plf I SHEARWALL DIAPHRAGMS., 5/32", CDX.O.R OSB( EXP1),OVER FRAMING W/1/2".GYP.,INTERIOR ! AILING FORSHEATH INGS HALL-BE 8d @ 4" E.N.,& 12" F.N.OR 7/16"x2"x16Ga S ple 2" E & 8" F N si to @ .N, AILING FOR GYB SHALL BESd;@,4'' E.N.,& 10" F.N. OR EQUIV. X FRAMING MEMBER RECEIVING EDGE NAILNIG ALLOWABLE SHEAR=350*1.4+125=615.PLF w/REDUCTION TYPE II SHEARWALL PERFORATED I . 5/32" CDX OR OSIB( EXP1) OVER FRAMING W/1/2" GYP. INTERIOR AILING FOR SHEATHING.SHALL BE 8d @ 2" E.N.,& 12 F.N. 1 E.N:SHALL.BE STAGGERED) Sz R 7/16"x2"x16Ga Staple @ .1" E.N.,& 8" F.N. (E.N.SHALL BE STAGGERED) X OR.(2)2X FRAMING MEMBER RECEIVING EDGE NAILNIG LLOWABLE:SHEAR=590*1.4+125=951 PLF w/.REDUCTION YPE II SHEARWALL PERFORATED i 2).15/32",CDX OR OSB (EXP1).OVER FRAMING (ON BOTH SIDES) AILING FOR SHEATHING SHALL BE 10d @ 2:" E.N.,& 12" F N. E.N.SHALL BE STAGGERED) _ S3 R 7l16"x2"x16Ga Staple @ 1" E.N.,& 8" F.N. (E.N.SHALL BE STAGGERED) X OR(2) 2X FRAMING.MEMBER RECEIVING EDGE NAILNIG LLOWABLE-SHEAR 715*2*1.4=20.02 PLF w/.REDUCTION, YPE II SHEARWALL PERFORATED . I. RSTA#6291 STRUCTURAL CALCULATIONS Sheet 8 of HAVEN HOMES (Stern Residence; Green ort;N 'R&S TAVARES ASSOCIATES TEL (209)863 8928 3324 SANTA FE STREET.; •. FAX: (209)863 8952 RIVERBANK; CA 95367 AV1S.R ES I ALLOWABLE CONNNECTOR DESIGN VALUES (BASED ON SPF#2) .,: SIMPSON CONNECTORS A35 12 -8d NAILS ShearallowA35 = 60 LB H2 5 . 10=,8d NAILS TensionallowI125 36 LB MSTC52 48 1.td NAILS - TensionallowMSTC52 414 LB LSTA12 5 10d NAILS EA END Tensionallo wLSTA12 69. LB STHD14RJ:.- 38 16d NAILS Tension - 502 LB allowSTHD14RJ i ST6224 28- 16d NAILS Tension allowST6224 254 LB I STRAP 1 1%4"X 16"0.:19"Ga . Tension allowST1ZA.P�— 50 LB ' 44 8d NAILS ON TOP OF: CEILIN�G:JOIST 3-8d.NAILS AT EACH PLATE &AT MARRIAGE.WALL i - I : I - j RSTA#.6291 STRUCTURAL CALCULATIONS Sheet 9 of HAVEN HOMES (Stern Residence, Greenport, N`n i R&S TAVARES ASSOCIATES TEL: (209)863 8928 . 3324 SANTA FE STREET _ E 1FAI� S " • , ,��yax�rrtrr�s ". . • FAX (209)863 8952 RIVERBANK,.CA,95367 A IAPHRAGMbESIGN Y_ FOR ROOF FRAME 1 • _ :ROOF D . .. SHEAR IN TRANSVERSE 0 ROOF DIAPHRAGM �RF T 339 plf See Summaryin Sht 5 �P .44 T wR-P w T ` 266 plf into dries 1 Si 2 2 28 since � .T=266 plf` <. vALLOW 308 plf RF T- R i ... — — SHEAR IN LONGITUDINAL(a=� ROOF DIAPHRAGM 1 =308 plf See.Summary in Sht.5 — I vRF L 28 w — RF L wR.F_L—98 plf Anto Lines B &C, 2 44 since plf , < VALI O.W RF L=231 plf -I . TRANSVERSE P IL. ROOF A FRAME 3 _,_• 9.12 ROOF. ROOF. B FRAME 1 FRAME 2 ..... - LONGITUDINAL - 9:12. i . --�---- ---------------------- - _ 9.12 .308 PLF ` ---- 27r 6 r 42' 9:12 I. 9:12 C �r G r D I 2 RSTA#6291 STRUCTURAL CALCULATIONS Sheet 10 of HAVEN HOMES i ' (Stern Residence, Greenport, NY). R&S TAVARES ASSOCIATES TEL.(209)863 8928' 332E SANTA,FE STREET A ARES FAX: (209)863 8952 RIVERBANK,,CA 95367 � - ;nss.►rntcs ROOF DIAPHRAGM CONTINUITY CHECK FOR ROOF FRAME 1 MODULE TO MODULE CONNECTION na ROOF RIMBAND ALONG MATELINE I . NOTE; DEEP BEAM HORIZONTAL SHEAR .. ' .TRANSVERSE' 339 PLF vRF. T=339 pif plfI�-2o A ROOF , FRAME �u 4. • �� ROOF .. � ROOF FRAME] TENs1oN. FRAME 2. - .. LONOITDDMAL '6b7 LO : - I:.. ..308 PLF - MATE=4.24KIP ------------- p{• 42'. i b. C - D VRF L`27.5 FMATE z FMATE-4 - �— 241. lb ALLOW 16d_nail 122 1.6.1.1 lb ALLOW =215 Ib 16d nail . ALLOW 16d nail Spacingreq F 12 Spacing 26 7 In MATE. 9 44 ROVIDE 2 16d NAILS PER BAY ROOF DIAPHRAGM RIM CONNECTION MODULE TO MODULE CONNECTION ROOF RIMBAND AT ENDWALLS - NOTE : CHORD FORCE CONTINUITY vRF L,27:52 d. 8 FCHORD — ' 44 tension force to chord FCHORD—663 LB .: i SINCE TensionallowST6224=2540 F 663 . LB < LB CHORD _ Tension a11owHTT16 3695: ROVIDE ST6224 SIMSON STRAP RIMBAND GABLE END WALLS I ' ROVIDE DBL HTT1.6.SIMSON TIE ROOF.MATING LINE END WALLS OPTIONAL .. j RSTA#6291 STRUCTURAL.CALCl1LATIONS Sheet 11 of :. . HAVEN HOMES (Stern Residence Greenport, NY): . i - R&S TAVARES ASSOCIATES TEL (209)863-$92$ 3324 SANTA FE STREET A1TARES RIVERBANK; CA 95367 ... - ock-A ,FAX (209)863 8952 ' ROOF DIAPHRAGM DESIGN '`FOR ROOF FRAME 2. SHEAR IN-TRANSVERSE(cD ROOF DIAPHRAGM vRF_T2 =402 plf. See Summary to Sht 5 X. - . �RF T2'27.5. I N'RF T — "163 wRF T. plf into:Lines 2 &3 77 -2.34 since w 163 . Of VALLOW 1ZF T=308 plf - - R SHEAR IN LONGITUDINAL Ca ROOF DIAPHRAGM vRF L2=364 plf See Summary in Sht. 5 i 34 vRF L2" w _L — w L 225. plf . into Lines B.Bi D 2.27.5... _ j'. since wRF_L L=231.225 plf < vALLOW RF plf CR f `TRANSVERSE `. -. 402 PLF .. ROOF t /� A - . - FRAME 3 1_ t - ROOF ROOF. :. } FRAME I FRAME 2 } LONGITUDINAL 9:12 ' 9 12 ---- --- -- ----- -- 27'-6" 42' 364 PLF ------ --- 9:12 -'I i .1: 9. 2 _ - C _. ��6; . D 44'-0 2T,G" 1 2 RSTA#6291 ` STRUCTURAL CALCULATIONS Sheet 12 of HAVEN HOMES .(Stern.Residence, Greenport, NY) . R&S TAVARES ASSOCIATES TEL: (209)863 8928 3824 SANTA FE STREET Av Res FAX (209)863 8952 , RIVERBANK;CA 95367 ' ROOF DIAPHRAGM CONTINUITY CHECK FOR ROOF FRAME 2 777777 —MODULE TO MODULE CONNECTION(a) ROOF RIMBAND .ALONGMATELINE NOTE:.DEEP BEAM'HORIZONTAL SHEAR. TRANSVERSE . 402 PLF RF_T2 -402 pif . � v =364 pif . n .0 RF. L2 0.00E I / O FrtanlE S-0. ROOF. .ROOF $ION I W . . .. FRAME 1 FRAME.: , ron LB - ------ ------ --- --- - LONOITMWIL �_ i _�Iy.♦ zr-6�. 42 ., ...... :. MAT�557 KIP. F i I f 1 .,C 1 -- --- � 44'-0" I 2 3 •27.5 ' FIVIATE -: 2 FMATE 5525 lb HE ROOF FRAME.2 WILL BE CONTINUOUS.AT THE MATING LINE BY A SITE APPLIED !� AP - MODULE TO MODULE CONNECTION A ROOF RIMBAND AT ENDWALLS NOTE : CHORD:FORCE CONTINUITY 'YRF L2 27.5 2 FCHORD 34 tension force to chord FCHORD- lol 1.., LB TensionallowST6224-2540 LB SINCE: F : loll LB.: < . CHORD- Tension allowHTT16=3695 ;LB PROVIDE ST6224SIMSON STRAP RIMBAND GABLE ENDWALLS ®.. f ROVIDE DBL HTT16 SIMSONTIE - ROOF'MATING LINE END WALLS OPTIONAL) RSTA#6291 STRUCTURAL CALCULATIONS Sheet 13 of (Stern Residence, Greenpori, NY), R&S TAVARES ASSOCIATES TEL: (209)863 8926, 3324 SANTA:FE STREET FAX- (209)863 8952 RIVERBANK, CA 95367 , A'.�ARES s9'ixlar�s . ROOF DIAPHRAGM DESIGN ` FOR ROOF FRAME 3 SHEAR IN TRANSVERSE(a ROOF DIAPHRAGM v 306 Of See Summaryin Sht 5 RF_T3 ,I v RF_T3 8 wRF T3 wRF_T3 —61 plf into Lines A&B 2.20 since wR_T3 =61, plf VALLOW RF T-308 plf " R SHEAR IN LONGITUDINAL(cr_ ROOF DIAPHRAGM L3 =260 plf See Summary in Sht. 5 L: vRF I3.20. w :_ — — plf into Lines 2 &3 w � 95 RF_L3 2.27.5 . RF_L3 — • since.;, w —95 plf <. VALLOW RF L=231 plf RF L3 - - R TRANSVERSE I .. - 260 PLF xooF 1 A I 306 PLF FxrmleS LONGITUDINALE - ROOF. '- ROOF FRAME I FRAME 2 9:12 t - I 9:12 i ------ -- 27'6" 42' i --- 9 ----- :12 I 9:12 . _6 D '44'0 E°---2T-6" i RSTA#6291 STRUCTURAL CALCULATIONS Sheet' 14 of -HAVEN HOMES (Stern Residence;'- Greenport, NY) R&S TAVARES ASSOCIATES 3324 SANTA FE STREET TEL:'(209)863-8928 RIVERBANK,.CA 95367 AIES (209)863 8952 fr4rP$ ROOF DIAPHRAGM CONTINUITY'CHECK �' FOR ROOF FRAME 3. -.MODULE TO MODULE CONNECTION 0- ROOF RIMBAND ALONG MATELINE 77 NOTE : DEEP'BEAM HORIZONTAL SHEAR ' LONGITUDINAL, v —306 plf; RF T3-_ `'RF L3 =2% Of I „ A TRANSVERSE 306 PLE. ,�26RP - ROOF ROOF 'MSTON . FRAME 1 FRAME Z: _��q - ----- -. I . C .. .. .: 7 .. D I 2 3 na-0° v 20 '.r.. ATE — RF L3 F FM — 2, MATE 59 9 Ib ALLOW 16d nail = '122 1.6.1 1 lb ALLOW —215 lb 16d`nail ALLOW 16d nail Spacingreq :.. — •12. Spacing =7.9 in FMATE`' ROVIDE 2 1.6d NAILS PER BAY ROOF DIAPHRAGM RIM CONNECTION -MODULE TO MODULE CONNECTION Ccr� ROOF RIMBAND AT ENDWALLS NOTE.: CHORD FORCE CONTINUITY j. 2 . v 20 RF U. FCHORD 8_ tension force to chord_ FCHORD— 1624 LB • Tension SINCE F 1624 LB < allowST6224=2540 LB , CHORD— TensionallowHTT16—3695 LB . i ROVIDE ST3224 SIMSON STRAP RIMBAND GABLE END WALLS : i ROVIDE DBL HTT16 SIMSON TIE ROOF MATING LINE END WALLS OPTIONAL RSTA#6291: STRUCTURAL CALCULATIONS . Sheet 15 of HAVEN HOMES (Stern Residence- Green NY). R& S TAVARES ASSOCIATES ! TEL: (209)863 8928 . 3324 SANTA FE STREET AARES FAX: (209.)863 8952 RIVERBANK, CA 95367 - °assa:r�3rs SUMMARY SHEAR FORCE DUE TO ROOF DIAPHRAGMS (INTO 2ND FLOOR SHEARWALL) R 44 INTO LINE — LB 1 RF-T 2 R 1 —7447 R __v 44 INTO LINE 2` 2 - RF_T 2 R2 7447 LB 27.5 R$ vRF-L 2 INTO LINE B RB =4241 LB 27.5 RC VRF L INTO LINE C R =4241 LB _ 2 C 3H ([�i 2ND EARWALL FLOOR Rl Rz l . Ham' " > S'-0" Re-► _ ............ .. I B (2)3.25'+(3)2.5'OPEN OPEN --==------------------------ 27'-6 42' --------------- 2.5' (6)3.25'OPEN OPEN D / 44.E 27'-6" RSTA#6291` STRUCTURAL CALCULATIONS Sheet 16 of HAVEN HOMES (Stern Residence, Greenport, NY) R&S TAVARES'ASSOCIATES TEL` (209)8638928 3324 SANTA FE STREET.. tA A) ES FAX: (209) 86.3 8952 RIVERBANK, CA 95367 ,�s (kznrs CHECK SHEARWALL & OVERTURNING aO 2n� FLOOR (DUE TO ROOF DIAPHRAGM) Line 1 (2nd FLOOR) 51IEARWALL @3HO FLOOn nI ff R 1 7447 lb, L := 27.5(t ale-io.o sw °^-► ' L1_ L .—2.25 L1 =25.25 ft 2.25 OPEN - i . -4Y 1 - (6)J23 OPR! OPEN - Percentful'1_ht = L 0.92 Rc— Percentfull ht F f sw D IJ . +•-0• rr-6• Ratio 0.93 per Ta ble 3B ) -- .' effective `J W FCM, b Ratio: 615 See Shearwall Schedule effective — effective' , ueffectiive=572 plf R V1 = L 1 Vl =295 plf <.' —572 plf ShearWall . 1 veffective_ S 1 For 27'-6" Perforated ShearWall(w/93% Effective Shear) an LINE 1 _ Ls ;,=27.5 ,ft Hwall 8 'ft Wall Height, _ 2 i M R H + U hft 4 Lsw OT 1.', wall P 2 MOT= 89564` lb-ft 2 - L L MR'=.wwDL•Hwall' sw + wRDL'4 sw M 58988 lb-ft 2 2 R 2- -MR -39325 < MOT 89564, lb-ft There is OverTuming i M 2M < Tensiona110WMSTC52=4145 lb or equiv. OT- 3 R T =. T= 1827 lb CENTERED @ 1ST&2ND FLOOR Lsw, MODULES' , @GABLE END POST. USE MSTC52 A EA. END OF 27'-6" PERFORATED SHEARWALL(a)2nd FLOOR OF LINE 1 RAVE HOMES STRUCTURAL CALCULATIONS Sheet 17 of -HAVEN HOMES (Stern Residence, Greenport, NY) 1. R&S TAVARES ASSOCIATES EL: (209)863 8952 3324 SANTA FE STREET 1 F AMARES 'FAX: (2 9 8 _.RIVERBANK, CA 95367 � •�s�;�'rrtr��, : Line 2 (2nd FLOOR) SHEARWALL@?°FLOOR R2 =7447 lb Lsw _ 27.5 ffE--xo-0_�I O T ^ L2 • LSW-2 5_ 1 L -25 , ft (2)3.xS+(3)25'OPEN 1� 2.25' I OPEN ------------------- Percen L2 Percent =0 91 (brizs'oPEN o EN " tfull_ht —. L full ht . R. sw �.�.°O I: Ratioeffective '0.91 per Table 3B 1 :. WFCM Ueffect)ve Ratioeffective'615 See Shearwall-Schedule ue =560 plf. ective I R2 V V =298 Of. <. — Of ShearWall 2. .'_' L 2 veffective—560 : 1 .2: . For27'4.' Perforated ShearWall(w/91% Effective Shear) (a LINE 2 Lsw`' 27.5 ft .i Hwall 8 ft Wall Height Lsw I. MOT:= R2'Hwall+UpLft•.4 MOT=89564 lb-ft L . 2 ` L 2 sw 5w 1 MR wWDL•Hwall•. + �WRDL�'4' MR=58988 lb-ft 2 2 2 3 MR=.393'25 < MOT=89564 . lb-ft There is OverTurning MOT �MR TensionallowMSTC52=4145 lb or equiv. T 3 T= 1827 lb- CENTERED @ 1ST&2ND FLOOR . LSw MODULES , @GABLE END POST. USE MSTC52 (a)EA. END OF 27'-6" PERFORATED SHEARWALL(cry 2nd FLOOR OF LINE 2 " RSTA#6291 STRUCTURAL CALCULATIONS Sheet 18 of HAVEN HOMES (Stern Residence, Greenport,.NY) I. R&S TAVARES ASSOCIATES TEL: (209)863 8928 3324 SANTA FE STREET, AVAI ES FAX: (209)'863 8952: RIVERBANK,.CA 95367 ,. S'AS t]+'f ATf 5 71 Line B (2nd FLOOR) m. . -. ... ,. SHEARWALL FLOCR .`.: : • R a RB..-:4241 lb' LSD, = 44 ft -" - CIE-20-0 A L L 3252 -253 B ' SW ao—► — „ (2)3.25}(3)23 OPEN : LB =3O ft - OPEN - -- ------------- -... LB i3' - PeraeI) (6)7]S-0PEN" OPEN tfii11 ht Percentfull ht 0.68 G 44 2T6 It Ratio 0.73 per Table 3B: : effective WFCM. veffect(ve Ratioeffective'615 See Shearwall Schedule. v -449 plf effective - .. ective B .. v -eeffectie ShearWal4VB V1 p L si For 44'-0 Perforated ShearWall(W/73% Effective Shear)(aD LINE B Lsw=44 ft - Hwall - 8 ft Wall Height 2 28 Lsw MOT'= RB'Hwall+ Uph#t 4 MOT= 168266 lb-ft . 2 . L2 Z M w H sw + (w 28 Lsw . MR-58988 lb-ft ' wall 2, l RDL)' 4 2 2 M 12972 < M b-ft Thereis.OveTR uning3 OT 2 MOT 3 MR T=876 lb Tensiona110WMSTC52=4145 lb or equ iv. 1 = r�- � . „ .Lsw" LOCATED @GABLE END FACE LINE A&LINE B USE MSTC52 Ct�EA END OF 44'-0" PERFORATED SHEARWALL(a)2nd FLOOR OF LINE B i. RSTA#6291. STRUCTURAL CALCULATIONS Sheet -19" of HAVEN HOMES (Stern Residence, Greenport, NY),: R&S TAVARES ASSOCIATES TEL: (209)863 8928 3324 SANTA FE STREET FAX: (209) 863 8952. RIVERBANK, CA 95367: AV�RES lH LtirgS Line C (2nd FLOOR) sitrAmA"L@2D9 FLOOR R 424.1 lb L = 4 ft �C� sw' 4 - - :�iIF-2a-0—jl ' 1J L L 3.25.6 L —24 5 ft ._ . C.' $W .. i-+ '(2)J25'+(3)2.5'OPEN . OP ________________ _______ - . 2.25' err full ht=0.56 2.5' LC _.l Percent f Percent ull ht — L — (5)733'OPEN OPE N $w per Table 36 Ratio effective 0.69 E 44-0•. IT6 WFCM veffect)ve =-Ratioeffective.615 See Shearwall Schedule. v 424 plf effective— RC VC.:= V 173 plf u =424 Plf ShearWall S1 - L effective C , For 44'-0" Perforated ShearWall (w/69% Effective Shear) a-LINE C Lsw=44 ft Hwall:= 8 ft Wall Height M := R + U lift•28 I s OT C•Hwall P w M 168266 lb-ft 4 2 OT "• 2 2 M _ w 1 sw ..+,W 28 .I sw MR = 1.94568 lb-ft R WDL'Hwall . 2 RDL 4 2 2 _ I. 3 MR' 129712 <. MST= 168266 Ib-ft There is OverTurning I 2 T MOT- 3 MR FT 876 lb TerWonallowMSTC52=4145 lb or equ iv. 1 sw LOCATED @ GABLE END FACE LINE - A& LINE B.. USE_MSTC52 A-EA END'OF 48'-0" PERFORATED SHEARWALL 2nd FLOOR OF LINE C RSTA#6291 STRUCTURAL CALCULATIONS Sheet 20 of i HAVEN HOMES (Stern Residence Greenport, NY)- iI R&S.TAVARES ASSOCIATES TEL: (209);863 8928 3324 SANTA FE STREET FAX: (209)863 8952 RIVERBANK, CA 95367 AVARES p$R�I.tFI?S 2nd FLOOR DIAPHRAGM DESIGN SHEAR IN TRANSVERSE(a)- 2nd FLOOR DIAPHRAGM YFLR2 T=356 plf. See Summary in Sht. 5 dell w vFLR2_T 44 wFLR2 T 285 plf 'into Lines 9 &2 FLR2_T 2.27.5 — since 285 plf < w FLR2'T VALLOW FLR T=372 If I SHEAR IN LONGITUDINAL Ccil 2nd FLOOR DIAPHRAGM _ r I `'FLR2 L =310 plf See Summary in Sht. 5 vFLR2_L'27.5 7FLR2 L WFLR2 L -97 : plf into Lines B &C — 2.44 C since.. w'FLR2 L 97 plf < V . —280 plf ALLOW FLR L TRANSVERSE 356 PLF f�>I< i A ' ROOF ;n,; FRAME 3 9:12 1 � .. .. . . B 2m FLOOR ROOF DIAPHRAGM FRAME 2 LONGITUDINAL _ 9:12 ' ----------------------------- G 42 . . 2T- ' 310 PLF --= ------------ 9:12 , -_...--._.-. _:..... D 44'-0 1 2 3 . RSTA#6291 STRUCTURAL CALCULATIONS Sheet 21 of HAVEN HOMES (Stern Residence, Greenport, NY) R&S'TAVARES ASS 6CIATES TEL: (209)863$928 3324 SANTA FE STREET � RIVERBANK, CA 95367 v '�E (209)863 8952 2nd FLOOR DIAPHRAGM CONTINUITY CHECK 1 MODULE.TO'MODULE CONNECTION FLOOR RIMBAND ALONG MATELINE . .`NOTE DEEP. BEAM HORIZONTAL SHEAR, '"""$"E'�e v _3356 56 pif ICI —�L _O FLR2 .T T 310 plf wDDR ��Ez nIne�ixnonl , T s FLR2 L xTo riF . ` .. c O aa•-0= xTa v 27.5 MATE F E='4256 lb F FLR2_L • T . 2 ALLOWbolt 1080 ....,.ALLOWbolt 1080 lb -ALLOWbolt W. Spacingfe9:: F,. Spacingreq — 11.2 ft MATE 44 :PROVIDE 1/2" DIAM.THRU:BOLTS 8'0.c. .FLOOR PERIMETER BEAMS ON SITE MODULE TO MODULE CONNECTION an 2nd FLOOR RIM BAND ATENDWALLS NOTE CHORD.FORCE CONTINUITY vFLR2 L'27.5 z F 8. tension force to chord CHORD= CHORD 44 F 665 LB I- eiisionallowST6224=2540 LB SINCE F 665 LB G CHORD Tensionallo 6=3695 LB wHTTI ' ROVIDE ST6224 SIMSON STRAP @ RIMBAND GABLE END WALLS rVIDE DBL HTT16_SIMSON TIE @ 2ND FLOOR MATING LINE @ END WALLS IONAL RSTA#.6291 STRUCTURAL CALCULATIONS Sheet 22 of HAVEN HOMES (Stern Residence, Grpenport, NY) . R &S TAVARES ASSOCIATES # TEL: (209) 863-8928 3324 SANTA FE STREET T FAX: (209)863 8952 . V RES RIVERBANK, CA 95367 r - �s J• 2nd FLOOR DIAPHRAGM CONTINUITY CHECK( MAIN BUILDING TO PART 2'& 3) j 1 . - MO 7 DULE TO MODULE CONNECTION (cil 1st FLOOR RIMBAND -ALONG'MATELINE " NOTE DEEP BEAM HORIZONTAL SHEAR TRANSVERSE . 356 PLF - I' vFLF .T=356 plf I T v 10 3 plf FLR2 L _ _ Tm FLWR _—OW �TaNssx T --, w TwlNni DIAPFRtACM Te+aw.- �FRAME2 �m - - TtN9lON -ml In 27fi' 42' I - 710 PLF F AlnlE-416KIP - -e as - Te-eAMP- - -- '� 4411- S'-j I. v 27.5 FMATE 2 FMATE'.-4898 .. Ib '. ALLOW 1080 bolt ALLOWbolt= 1080. ib. ALLOW Spacing bolt req F Spacingreq - 6.1 ft MATE' I 27.5 PROVIDE 1/2" DIAM.THRU.BOLTS 6'O.c. FLOOR PERIMETER BEAMS.ON SITE . - L MODULE TO MODULE CONNECTION na 1stFLOOR RIMBAND •ATENDWALLS I NOTE : CHORD,FORCE CONTINUITY , vFLR2 T'(27:5+27.5)2 FCHORD 8 tenslon force to chord FCHORD-.4898 LB 27.5 2•TensionallowST6224=5080 LB C SINCE F -4898 LB < % CHORD- 2 Tensional 7390 LB IOWHTT16= PROVIDE 2 ST6224SIMSON.STRAP RIMBAND GABLE END WALLS .` rOVIDE(2) DBL HTT16.SIMSO I.TIE @ 2ND FLOOR'MATING LINE@ END WALLS TIONAL . RSTA#6291 STRUCTURAL CALCULATIONS' Sheet 23 of HAVEN HOMES :(Stern Residence, Greenport, NY) R&S TAVARES ASSOCIATES " . TEL: (209)"863 8928 .3324 SANTA FE STREET- RIVERBANK, CA 95367 ,' AIES 3 FAX -, 5 SUMMARY SHEAR FORCE DUE TO, 2ND FLOOR DIAPHRAGM/ROOF DIAPHRAGM 44 R1-FLR2'- V FLR2 T' 2 R 7838 LB.' - 1_FLR2- 44 27.5 R2_FLR2 vFLR2- T'.2 +vF_T2':22 R2 FLR2= 13551 LB . j 34 8 -. RA FLR2 vRF L2 2 +..vRF_T3 2 RA FLR2-'7403 LB 11 34 8 RB_FLR2 2 vRF L2' + �RF'T3 2 . R 7403. . LB _ _ B_FLR2 34. 8 RC".FLR2 - vRF L2 2. + VRF T3 2 RC FLR2=7403 LB 34. 8 RD FLR2:=.VRF L2 2. + vRF T3 2 -FLR2= R 7403 -LB D . I' COMBINED SUMMARY SHEAR FORCE TO 1ST FLOOR SHEAR WALL R1. COMB Rl + R1_FLR2 R1 COMB= 15285 LB R2 J.:COMB R2 + R2 'FLR2 R2 COMB=20998 LB. i 27.5 R3_COMB�_,VRF_T2 R3 C MB=5714 LB 2 .. - O . - f RA" COMB RA. FLR2 .. ' . RA COMB =7403 LB i RB_COMB - RB,+ RB_FLR2 RB COMB= 11645 LB RC COMB RB.+'RC FLR2. RC COMB= 11645 LB ' j . is RD"COMB RD FLR2 RD COMB -.7403 LB 1 a - SHEARWALL©1'FLOOR R,ronm R,roem j roam—. :.. ... 20'-0"�I A - .6.25'+(2)2.25'+6.25'OPEN v - - .. 225' -I +3.25' - +2 25' (2)3.25' - +3.25' _ �27.6"� 42' +I6.25' OPEN 2.75' OPEN. I . OPEN 4 3.25'+6'OPEN .Ro rorm'�.._._..__ ._......_ _.... .__ __. - _C 3)3.25'OPEN RSTA#6291 STRUCTURAL CALCULATIONS Sheet 24 of HAVEN HOMES - (Stern Residence, Greenport, NY). I R&S TAVARES ASSOCIATES y TEL: (209)863 8928 3324 SANTA FE STREET FAX: (209)863 8952 RIVERBANK, CA 95367 AARES � A�5nCk rAk'3?.? n CHECK SHEARWALL 8:OVERTURNING (a)1ST FLOOR {u®i"Fwoa Line 1 (1st FLOOR) R. .s" wn n .� - , a1 _ RI_COMB= 1.5285 lb Lsw':= 27.5 ft, 0 m325•oren I LI Lsw 3 25 2 a. .=►' O 625'+(2)2.26 6.25 OPEN 22S I .. L1 =21 ft +3.73' .' :... , -------------------------- - +3.5' zra• Jr -- L 1 OPCN .. 27r OPEN' I .. OPEN PercentRill_ht L_1 Percentfull ht 0.76 J 3]:.s rEN SW 3)37r OPEN Ratioeffective 0:80 per Table 3B 1 2 3 WFCM • { veffective Ratioeffective'2002 See Shearwall Schedule veffective= 1602 plf j R1_COMB V V =728 Of < u = 1602 plf ShearWall 1 L effective . 3 •. 1 For 2T-6" Perforated ShearWall(w/80% Effective Shear) Al LINE 1 j Lsw=27.5 ft. Hwall 9: ft Wall Height MOT:=.Rl 17+ R1 FLR2.Hwall MOT= 197141 lb-ft 2 2 2 i MR wWDL•.17�Lsw .+ wRDL.4.LSw +.wFDL"4'Lsw MR= 117975 lb 2 2 2 2 MR=78650 < MOT= 197141 lb-ft There is OverTuming 3 _ I 2- MOT— 3 MR Tension allowSTHD 14RJ=5025 lb or equ iv. T: T=4309 lb Lsw INSTALLED @ FOUNDATION WALL @ GABLE END USE STHD14RJ' (cD EA: END OF 27'-6" SHEARWALL Cad 1ST FLOOR OF LINE 1 { RSTA#6291 STRUCTURAL CALCULATIONS Sheet 25 of i HAVEN HOMES (Stern.Residence, Greenport, NY) R&S TAVARES ASSOCIATES TEL (209)863'8928 3324 SANTA FE STREET FAX:(209)863 8952 RIVERBANK, CA 95367 . 'Line`2 (1st FLOOR). MEARWA49J 1-F100R . R2 COMB=20810 Ib Lsw:= 24 ft 1 1 R --• I�I�-z�-0'�I 0- - 7jL. A LS^,.—2 75 - L2 =21.25 . ft Re we~- eas+(z>zzs•.+e2s OPcx —O :{ L ------ ----------------- .- ZTS - 42' (2)3.25 -.2.75' Percentfull ht Percentfull ht= 0. hM 89 OPEN OPEN I SW ]:2S 6'OPEN�.�.—. (4 . Ro-m.e�► Ratioeffective.— 0!82 , .. per Table 36 W FCM ueffectrve = Ratioeffective.2002 See Shearwall Schedule ueffective= 1642 plf R2 COMB V2; L V2=979 Plf veffective= 1642 plf. ShearWall S3 2' For 24'- 0" Perforated 8hearWall(w/82% Effective Shear)(a�LINE:2 when the overturning force is about the.exterior end- LsN;=24 ft Hwall =.9 .ft . Wall Height - I M c= R 17+R 8 M =2 lb-ft OT 2 2 FLR2. OT . . 33504 2 2 2 Lsw Lsw. r 13.751 Lsw MR•= wWDL 1T +.wRDL'8 + wFDL'I 4 + I' +.FWRDL+ �'FDL�'4.4.75•Ls��, 2 2 \ 2 2 . MR= 143208 Ib-ft- 2 - 3 MR 95472 MOT=233504 lb-ft There is OverTurning. I l MOT-_3 MR _ �. TensionallowHDQ8 -7210 lb or equiv. T:_ T=5751 lb SW GABLE INSTALLED @ FOUNDATION WALL @ GABLE END , I RSTA#6291 STRUCTURAL CALCULATIONS Sheet 26 of HAVEN HOMES (Stern Residence; . Greenport, NY) . R&S TAVARES ASSOCIATES TEL (209)863 8928 :3324 SANTA FE STREET FAX (209) 863 8952 'RIVERBANK,,CA 95367 AVsAIiES' .s Line 2 (1st FLOOR): _ when the overturning force is about the interior end For 24'-0" Perforated ShearWall (w/82% Effective Shear) an LINE 2 Lsw=24 It Flwall 9.: ft Wall Heighf MOT: R2,1"7"+ R2:FLlZ2 8 MST=233504 lb-ft M w 17 Lsw .+ w 8..Lsw + w r4 + 13 75 Lsw +:w 17 4 L R WDL. : 2 RDL 2 FDL I 2 )... 2 WDL. sw \\\ 1 MR . 150480 lb-ft° M `=100320 M 233504 Ib4t There. Ove,rTumin 3 R OT. , g- . > MOT .3 MR < Tensionallowl3DQ8-7210- lb or equiv. T — T.=5549 lb ; !, Lsw INSTALLED @ FOUNDATION WALL @ " G ABLE END. USE HDQ8-SDS3 W1 SSTB28 na EA END OF 24'-0" SHEARWALL(U 1ST FLOOR OF.LINE 2 4. RSTA#6291 STRUCTURAL CALCULATIONS Sheet 27 of HAVEN HOMES (Stern,Residence; Greenport,NY) . R&S TAVARES ASSOCIATES TEL: (209)863`8928 3324 SANTA FE STREET MARES FAX: (209)W3 8952 i RIVERBANK, CA 95367 . SNEARWALL®1'PLOOR Line 3 (1st FLOOR): R. . R�. R;� 4 5525 Ib' R L 42 I 3_COMB sw ft IEIE—ia-0�t 10 6 OPEN R..mm—► (2)J2SbPEN_ R-0' 7- L3 '= LSw-2.25 2 -3.25 -3:25- 16.25 2s+�2)21S+62s 2.a ------ ------------------- +J:2S } +2.25' . 2.75 ----------- (2) OPEN ' OP OPEN L3 14 75. ft w Jir,6'OPEN Ro -► l)J2J'OPEN Percen'full_ht = L Percentful1 lit-0:35 sw 1 2 3 Ratio .. .- 0.43 per Table 3B. . ' effective•-.,• . :WFCM ueffective:= Ratio effect •951 See Shearwall Schedule: u PIT rve effective p. V3 R3_COMB ,` V3 =375 plf u -409 plf ShearWall L3 �. effective 2 For-42%0" Perforated ShearWall (w/100% Effective Shear)'01 LINE 3 I . H' 9. ft : Wall Height �. Lsw 42 ft wall 9 _ 2 Lsw R 8 + U Uplift-4—MOT , 3_COMB' P 4 2 MOT=.111 44 ., lb-ft 2. 2 L. L MR N'WDL Hwall' 2 +.lw�L� 4 sw MR= 148176 lb-ft 11 2 3 MR= 98784 < MOT- 111444 lb-ft There is OverTurning 2 MOT— 3 MR TensionallOWSTHDI4RJ =5025 lb or equiv. T:_ Lsw T=301 lb INSTALLED @ FOUNDATION WALL @ GABLE END USE STHD14RJ O..EA.END OF 42'-0" SHEARWALL(a�1ST FLOOR OF LINE 3 RSTA#6291 . STRUCTURAL-CALCULATIONS Sheet" 28 of -HAVEN HOMES. (Stern Residence, Greenport, NY) . • I R.&S TAVARES ASSOCIATES TEL: (209),863 8928 s 3324.SANTA FE STREET FAX: (209)863 8952 RIVERBANK, CA 95367 ,' AVAIES f .;. . A Line A (1st FLOORI. : " SHEARWALL(a}I"FLOOR R 7403 Ib L - 20 ft. . R. wem R»® R A COMB Ls L =:L ._.3 25•2.: x m a--� A" A . -.sw .. E. 2a o• 3 I Re_cvnm_�..... ' t - 6.2 .25'+625'OPEN LA 13 5 ft - 2. 25 - +3 2S -- _ - +2 2Y ! . — ---- ----- ----- +325 2T6• 42' LA" --- +1625 Percentf (2)32s' `2.75 OPEN Uh ht OPEN. L r OPEN - : - SW 43.25'+6.OPEN .I Rc - PercentE ll hf ._. _ 250 PEN)3 44 i Ratioeffective 0.76 per Table 3B ' WFCM . . t.:. s. . veffechve -"Rat�oeffective-951 See Shearwall Schedule u =723 plf . effective " w. A COMB VA'_ -L .. VA=548 Plf <; . " veffective=723 plf ShearWa 11 S2 ! A For 20'-0" Perforated ShearWall(w/59% Effective Shear)(aD-LINE:A' 20 ft _"9 ft 'Wall Height Lsw, Hwall' 2 s H +Uplift I sw MOT RA COMB- wall.. . 2 MOT 81879 lb-ft # ; E 2 2 2 ' .t M •— w H Lsw -+w •4 .Lsw + w 4 Lsw M 43200 lb-ft R WDL wall' 2 " . RDL 2 FDL 2 R • I 2 . —MR. 28800 MOT 81879 Ib-ft 3 5025 lb or equiv. MOT-3 MR: TensionallowSTHD14RJ = T - T=2654 lb . f •Lsw -LOCATED @ GABLE END FACE USE STHD14RJ -EA END OF 20'-0" PERFORATED SHEARWALL(a)1ST FLOOR OF LINE A i • RSTA#6291. STRUCTURAL CALCULATIONS Sheet 29 of HAVEN HOMES (Stern Residence, Greenport, NY� R&S TAVARES ASSOCIATESI � TEL: (209)863 8928 i 3324 SANTA FE STREET, FAX: (20%863 8952 ' RIVERBANK, CA,95367 , AZTAIES Line B (1st FLOOR) .. .. ., SIIEARWALL@ f"A:ooR j ! R mw R'' R,�m RB COMB- ]1645 : lb : Lsw 49 ft 1 l � _ R..ma--►- A - j (2)72S6PEN LB Lsw_—6.25 —`2 2S"2-6:25 n —v 6.25' (z)z2s+s.zs OPEN t- ' . _ 2.2.7 .. .. J 25' . - - —+J ---- ---- -- S ITfi• 4Y Bi EL 2 ft zs OPoP EN .7s OPEN ... (4 73S 60PEN - • LB, _ -► 7)71S0PRl �§•fi•C' Percentfull_ht - L Percentfull_ht-0.65 sw Ratioeffectrve — 0.59 per Table 3B WFCM • 11 veffective:= Ratio efPective.951 See Shearwall Schedule i ` veffective 561 Of I..` RA COMB - — V — V 231 Of u —561 plf ShearWall B L effective— S2 B j For 49'-0" Perforated ShearWall(W159% Effective Shear) a LINE B = -ft _ 9 ft Wall Height L 49 sw Hwall Z. I � 27.5 Lsw ..MOT RB718 + RB'FLR2 Hwall+Uplift—• + 876.44 MOT=338832 lb-ft.— 4 2 Lsw 27.5 Lsw 27.5 Lsw j .— w 17 + w + w 67745 — lb-ft R- WDL 2 RDL 4 2 FDL 4 2 MR—4. " j � i ! 2 ! 3 MR=311830 MOT=338832 lb-ft There is OverTurning M _?M Tension OT 3 R � allowSTHD 14RJ 5025 lb or equiv. = T:= T'=`551 lb Lsw LOCATED @GABLE END FACE USE STHD14RJ (aD-EA. END OF 49'-Q. PERFORATED SHEARWALL(a�1ST FLOOR OF LINE A i jE RSTA#6291 STRUCTURAL CALCULATIONS Sheet 30 of HAVEN HOMES I (Stern Residence, Greenport, NY) ; j R & S TAVARES ASSOCIATES TEL. (209) 863 8928 3324 SANTA FE STREET: FAX: (209)863 8952 RIVERBANK,.CA 95367 A VAI�.ES {ss rarr> .. •' SNEARWALL®["FLOOR - .. t Line C(1st FLOOR) R R; R _ 1: 1 R - 11645 lb 'L f ._44 ft C_COMB sw' R--►� - - I�IF-:�-0-�I A LC = Lsw C-3 25 4.- 6 L -25 ft R —► u I 41 .. - 625+2 225+625'OPEN .- : .2 T +3.25 3. +z.2s .. ____.______(_'____-_____-__ +3.25 2r-6• 42' - , ' LB: (2)3.25 -- -----OPEN' F' Percen Percen 0.13 EN OPEN tfull hf L tfu11 ht- R<.�m (<Jzs b sw - EN ... Ilk- 4 'J3J33'OPCN I F 4-0• �j 2rfi•: Ratio : 0.54 per Table 3B effectwe' _ WFCM ' effective. Ratio effective 951., See Shearwall Schedule u —514. plf j effective— : RC_COMB VC._ L VC =466 Of < . veff = plf ShearWall. S.2 i C , effective 514 r For44'-0" Perforated ShearWall(w/54% Effective Shear) (a)LINE 6 j i. Lsw=44 . ft Hwall - 9. ft Wall Height 2 - { 27.5 sw MOT'= RC•18 + RC_FLR2'Hwall+Uplift—4 2 MOT 269821 lb-ft j.! i 2 2 2 i Lsw 27.5 Lsw 27.5 Lsw ! - MR:_:wWDL'.17 2 + w DL• 4 2 + WFDL' 4 .. . 2 M' =377157 Ib-ft E. f 2 251438 .. -26 . —MR < MOT 9821 lb-ft There is OverTurning 3 I 2. MOT=—MR TensionallowSTHD14RJ = 5025 lb or ecluro T _ 3 T=418 lb I # Lsw LOCATED @ GABLE END FACE USE STHD14RJ HOLDDOWN (off EA. END OF 44'-0" PERFORATED SHEARWALL(a�1st. .I FLOOR OF LINE B }l I - RSTA#6291 STRUCTURAL CALCULATIONS Sheet 31 of HAVEN HOMES ; (Stern Residence, i Greenport, NY) } R& S TAVARES ASSOCIATES TEL (209) 863 8928 3324 SANTA FE STREET FAX (209)863 8952 ! RIVERBANK; CA 95367: , AVARES 1 . SHEARWALL®1�FLOOR .. ,. I. Line D (1st FLOOR) R R 1 1 RD COMB 7403 -lb Lsw 27.5 ft R. . . . .... . au�s'orEN LD:= L5� -3.25 3 LD=.17.75 ft Rsmn—► 6.25'�Q)21 -629oPCN —O E - -- -- 2.25 .. +2.25. -3.25' - ) 2Tfi' 42' L7,, .. .' - OPEN- I. lLll Percent Percen —0.65 OPEN oPEN full ht L tfull ht— (4 325 OPEN - . sw OPEN Ro_--► - )l2S �§'�• i i Ratioeffective 0.74 per Table,3B V11FCM I veffective = Ratioeffective'951 See Shearwall Schedule. ueffective=704 plf RD COMB; V L 417 PIf u =704 Plf" ShearWall SZ D —_ effective D'- VD a For 27'-6" Perforated ShearWall W 746/6 Effective Shear) @ LINE D Lsw.-2Z 5 :ftrvall = 9 ft Wall Height F L 2 M R Uplift•34 sw 'MOT. 189151 OT D COMB'Hwall 2. 2 . . 2 M - �. H LSw .+w 34 LSw? If f R WDL wall' . 2. RDL 2 2 MR—`137259 lb-ft H 3 MR.= 91506 < MOT=189151 Ib-ft There is OverTurning MOT 3 MR < Tensiona1lowSTHD14RJ=5025 lb or equiV. T:= lb T=-:3551 Lsw 1LOCATED @ GABLE END FACE i USE STHD14RJ HOLDDOWN O EA END OF 27'-6" PERFORATED SHEARWALL a 1st - FLOOR OF LINE D". �. RSTA#6291 STRUCTURAL CALCULATIONS Sheet 32 of I j HAVEN HOMES (Stern Residence, j Greenport, NY) i R&S TAVARES ASSOCIATES TEL. (209) 863 8928 3324 SANTA FE STREET: FAX: (209)863 8952 RIVERBANK, CA 95367. 71 AVARES 16t FLOOR DIAPHRAGM DESIGN" 'FOR 11st FLOOR FRAME 1 SHEAR IN TRANSVERSE(cD- 1st FLOOR DIAPHRAGM i vFLRI T=206 plf, See Summary in Sht. 5 vFi Rl_T.44 w w 165 plf into Lines 1 &2 FLRl—T 2 27.5 FLRl_T I since WFLRl T= 165 Plf VALLOW FLR T=372 �Ifs ,. . SHEAR IN LONGITUDINAL(Q 1st FLOOR DIAPHRAGM II v — 179 plf, See Summary in Sht. 5 FLRl L_ ii vFLR1 L•27.5 WFLRl iL 2 44 wFLRI L=56 plf into Lines B &C since.. yr —56 i plf V 280 If FLRl_L ALLOW FLR L . 1 T ; RANSVERSE . 206 PLF i 20'_0°�� T A ROOF 8'-0" W B ; Isr FLOOR n1APFLOOR': xpcM3 'Ia DIAPHRAGM 1 �jI LONGITUDINAL - - - ____ .____a______ — ... ---------- .. 27'-6" 42' 179 PLF In>IDGR . DIAPHRAGM 2. - CONCRETE SLAB F �I� c f . I 16' D I , � i 1 2 . 3 I ! I i RSTA#6291 STRUCTURAL,CALCULATIONS Sheet 33 of { 'HAVEN HOMES.' (Stern Residence, Greenport, NY) Ii I if R&S TAVARES.ASSOCIATES TEL: (209).863-8928 _ 3324 SANTA FE STREET FAX:(209)863 8952 RIVERBANK, CA 95367 1' AVARES . - 1st FLOOR DIAPHRAGM CONTINUITY CHECK FOR 1st FLOOR FRAME 1 - . a MODULE TO MODULE CONNECTION (cD 1st FLOOR RIMBAND :ALONG MATELINE , . .NOTE : DEEP BEAM HORIZONTAL SHEAR rRANsveRSE 206 PLF vFLRI T-206. Of _ 179 Of — Tt vFLRi L &FLOOR LONGITUDINALDUPHRAC T-3TENSION27:-6" 42•179 PLF -FMATE=246KIPCONCRETE ,'SLAII . 1A I E ! 4 27 1 2 3 v 27:5 1 FLRl_L, FMATE,-= FMA� =2464 lb .. 2 . - ' G ALLOW .= 1080 bolt ALLOW bolt= 1080 Ib. ALLOW bolt Spacingreq F Spacing req= 19.3 ft 4 MATE 44 PROVIDE 1/2" DIAM.THRU.BOLTS 8'ox. . FLOOR PERIMETER.BEAMS ON SITE I F —MODULE TO MODULE CONNECTION d) 1stFLOOR RIMBAND •AT ENDWALLS NOTE : CHORD FORCE CONTINUITY . i vFLR l_L'2'7.5 z �. . A F _ 8 tension force to chord 1 ' CHORD 44 FCHORD=385 LB I SINCE Tension allowST6224=2540 LB j }. FCHORD-385 LB < i TensionallowHTT16 -3695 CB j ; j PROVIDE ST6224SIMSON STRAP RIMBAND GABLE END WALLSJYR i j ROVIDE DBL HTT16 SIMSON TIE @ 1ST FLOOR MATING LINE @ END WALLS s. OPTIONAL AG RSTA#6291 STRUCTURAL CALCULATIONS Sheet 34 of HAVEN HOMES (Stern Residence, I Greenport, NY) R &S TAVARES ASSOCIATES TEL: (209) 863 8928 . 3324 SANTA FE STREET:: AVAI ES FAX: (209) 863-8952 RIVERBANK; CA 95367 ,as�krtrF� 1st FLOOR DIAPHRAGM DESIGN FOR 1st FLOOR FRAME 3 SHEAR IN TRANSVERSE Q 1st FLOOR DIAPHRAGM v —206 pIf See Summary in Sht. 5 FLRI T3 —. . Y YIFLRl T3718 wFLRl T3 WFLRl.T3 plf 20 into Lines A & B1 2. _ 93: . since w 93: plf < V 372 If .; I ' FLRI T3 ALLOW FLR T= F SHEAR IN LONGITUDINAL (a 1st FLOOR DIAPHRAGM . `'FLRl L3 = 179 plf See Summary in Sht. 5 vFLRI L3'20 -wFLR1 L3 := w L 100 plf, into LinesB & C 2.i8 FRl L3 . i since : w, 100- plf' , < FLRl. L3 - L=280 If _ VALLOW_FLR F I TRANSVERSE. 206 PLF : - - _—.._..:............ .:_.. IHI�20,_0:,-�I ..-- ROOF /r - A .. - i m I I'FLOOR i DIAPHRAGM] . la• DIAPHRAGM 1 LONGITUDINAL .. .. .. 2T-6 42' 179 PLF to FLOOR . DIAPHRAGM 7 CONCRETE .. SLAB I i s I• f is C ........ 1 2 3 ; I RSTA#6291 STRUCTURAL CALCULATIONS Sheet 35 of HAVEN HOMES (Stern Residence, Greenport,`NY) ' , R&S TAVARES ASSOCIATES # TEL:(209)8638928 3324 SANTA FE STREET AAIES FAX: (20 9)863 8952 RIVERBANK, CA 95367 fd5f3 :Ltr. s s 1st FLOOR DIAPHRAGM CONTINUITY CHECK . ' FOR 1st FLOOR FRAME 3 . =MODULE TO MODULE CONNECTION C@ 1st FLOOR RIMBAND :ALONG MATELINE NOTE.: DEEP BEAM HORIZONTAL SHEAR TRANSVERSE .- 206 PLF -. - _206 plf FLRI T- V FLRI-L= 179 Plf` E-- •—�I n II u T y W _O - I FLOOR ..: DIAPHRAGM m4srBon -. . i 4T 179 PLF. .F MATE-2.46RII' •94 La. _ ! 54wo 464 I VFLRI L'27.5 FMATE 2 FMATE=2464 lb ALLOWbolt.:=-1080 ALLOW = 1080 lb. j... ALLOWbolt Spacing req F Spacingreq =7.9 ft.. MATE.: ; 18 PROVIDE 1/2" DIAM. THRU BOLTS 8' 0.c: FLOOR PERIMETER BEAMS ON SITE MODULE TO MODULE CONNECTION (a) 1stFLOOR RIMBAND •AT ENDWALLS NOTE : CHORD FORCE CONTINUITY. VFLR1 L'27.5z F 8 tension force to chord . . CHORD 18 LB=941 LB SINCE . F —941 LB < TensionallowST6224=2540 LB CHORD— TensionallowHTT16=3695 LB ROVIDE ST6224 SIMSON STRAP RIMBAND GABLE END WALLS ® } ROVIDE DBL HTT16 SIMSON TIE @ 1ST FLOOR MATING LINE @END WALLS OPTIONAL RSTA#6291 STRUCTURAL CALCULATIONS Sheet 36 of HAVEN HOMES (Stern Residence; Greenport, NY) R &S TAVARES ASSOCIATES . 3324 SANTA FE STREET TEL: (209)863-8928 AiIARES FAX..(209) 863 8952 RIVERBANK, CA 95367a s��r.Itirrs 1st FLOOR DIAPHRAGM CONTINUITY CHECK FROM 1s.tFLOOR FRAME 1 TO FRAME 2 &3 . - MODULE TO MODULE CONNECTION (a) 1st FLOOR RIMBAND :ALONG MATELINE' NOTE.: DEEP BEAM HORIZONTAL SHEAR TRANSVERSE - .. -. - VFLR1 T —206 plf v 179 plf IFL,1�- "—�1 FLRl_L - O . . .. _I&s wre-... 6 I"FLOOR �'hz RR• - ' - DIAPHRAGM. -TENSION ONO � L MUDINAL. - -388 LD _T ' 27-6 - 42 .. - 179 PLF F_MATE=246KiP •941 LD i AuiE CONCRETE - 1 . 2u1(tP SLAD I _ TENSION . - - -2464 LB, - F I �6� D - 44''0"— —�j 27'-6" > - I f I . I VFLRI L'27.5.2 FMATE = 2 FMATE=4928 lb ALLOWbolt:= 1080 ALLOWbolt_ ]080, Ib - ALLOWbolt: Spacing req Spacing :. =6 ft FMATE req ;. II. I 27.5 ROVIDE 1/2" DIAM.THRU.BOLTS @ 8' O.c.@ FLOOR PERIMETER BEAMS ON SITE — MODULE TO MODULE CONNECTION Cd) 1stFLOOR RIMBAND •AT ENDWALLS I j NOTE': CHORD FORCE CONTINUITY_. vFLR 1-L'(27.5+27.5)2 F 8 tension.force to chord CHORD:- 27.5 FCHORD=2464. LB _ I SINCE F —2464... LB < — I . TensionallowST6224 2540 LB CHORD— - TensionallowHTT1G=3695 LB i PROVIDE ST6224 SIMSON STRAP RIMBAND @ GABLE END WALLS' R ROVIDE DBL HTT16 SIMSON TIE @ 1ST FLOOR MATING LINE @ END WALLS OPTIONAL I . RSTA#6291 STRUCTURAL CALCULATIONS Sheet 37 of HAVEN HOMES a (Stern Residence, i Greenport, NY) I : ! i R &S TAVARES ASSOCIATES TEL: (209)863 8928 3324 SANTA FE STREET AVAI�ES FAX: (209)863 8952 RIVERBANK, CA 95367 ' LATERAL FRAMING CONNECTION LOAD-FROM WIND — ROOF RAFTER TO TOP PLATE CONNECTION A.) TO RESIST SUCTION Psuction 19 PSF Suction when wind is parallel to ridge. See Sht 5 i 27.5 16 27.5 16 2 Netsuction Psuction —I WRDL•. Net — 83 Ib 4 12, \ 4 12) 3 suction .. PER RAFTER ia SINCE Ib < Shea 40 .Ib OKsuction bolt SINCE Net 83 lb < Tension 500 lb OK suction — . a11owSTRAP— rovide-1/2" Bolt @ Each End of Each Rafter to Ceiling Joist& roAde 1 1/4"x 16"x,0.019" Ga Strap @ Top of Each End of Ceiling Joist to DBL op.Plate Over Plywood B.):TO RESIST SHEAR ;i wRF L=225 pif SHEAR TO END OF DIAPHRAGM. SEE SHT. 8 . 16 Psheear �'RF_L'— plf P —3.00 .LB 12 sheear- PER RAFTER i Toenail 0.83 88 3 (3) 16d Toe Nail ` Toe =219 LB i Toenail � SINCE. - Psheear=300 LB . < Toe 219 LB OK . Toenail = rovide 3) 16d Toe Nails Ea. End of Ea. CeilingJoist to Double Top Plate 1 , f RSTA#6291: STRUCTURAL CALCULATIONS Sheet- 38 of " HAVEN HOMES i (Stern Residence,. Greenport, NY) 'i R&S TAVARES ASSOCIATES .. TEL: (209) 863-8928 3324$ANTA FE STREET AARES FAX; (209) 863,8952 RIVERBANK,,CA 95367 �a�+frsrts WALL STUD TO DBL TOP PLATE&SILL CONNECTION (TO RESISIT SUCTION) only of 2nd Floor Psuction 19 „ PSF . Suction when wind 15 parallel to,ridge See Sht 5: i wFDL 2. 26.60 Net suction BOT [Psuction.- 7RDL+ wceil + — Stud to Floor Rim — �. 2 l3 4l .; 12 ; , . /. .J . . since Tension' -G95 lb LSTA12 60" Netsuction BOT 54 Ib. @ _ a11owLSTA12 p C. rovide.Simpson LSTA1.2 STRAP 60".ox. on 2nd Floor_Wall Stud to Floor Rim: i "x16"x0 019' .Tension.Strap e er. n o on the OthEd f Zd.t DBLhe Same tTP ud Shall,have the 11L4 I s r —.TOP PLATE SPLICES' wRF T= 163 plf,, i i Common = 90 Ib:.. Albwable 10d Common Nail for toe nailin - I0d nail face g Commonl0d nail' face I } Spacing = 12 S ' w ;. _ T' . Spacing 6.6 EACH SIDE !, F , ROVIDE MIN.:10d COMMON.FACE NAIL ALONG DBL TOP PLATES @ 4 E 4..STAGGERED.SPLICE w/Max.4 o.c•SPACING i - t I � i - I RSTA#6291. L STRUCTURAL CALCULATIONS. Sheet 39 . of HAVEN HOMES . . (Stern Residence,. I ; Greenport; Nl).'„ R&S TAVARES ASSOCIATES * TEL: (209) 863 8928 3324•SANTA FE STREET As FAX: (209)863 8952 RIVERBANK, CA 95367 ' c Tkf#S FOUNDATION SHEAR ANCHORAGE (vRF .T.+ VFLR2_T+vFLRl T) 44 Vbasel —2-(27.5 -2) Vbasel =777 plf _ (V + v +v 44 v ` +v 27.5 RF T FLR2_T FLR1 T)' ( RF_T2 FLR1_L3)' Vbasel 2 5,+ 7 Vbas 2318 Of ( ) + e2 (v + v 27.5 RF T2- FLRI_L3)'. Vbase3 Vbase3 —.420 plf 2•(42-2 -;21.) (vRF + v 6FLRl L3)•42 ubaseA'= 2•(20—2) VbaseA=512 plf sm - ' (vim I + vFLR2_L+ VFLR1_L) 26 VbaseB'- 2•{49-2) ubaseB =220 plf ' 26 v + v I ( RF_L FLR2 +v_L FLRl_L)' ubaseC =. . Z (44-2) :: VbaseC=247. plf (vRF L3 + vFLR1 L3).42 ubaseD _ 2 (27.5,—.2) VbaseD=362 plf ANCHOR BOLT LINE 1 LINE 2 LINE 3 LINE A LINE B LINE C LINE D N�� M 5/8" d i a m x 18" 16" O.C. 8" O.C. 32" O.C. 24110 C 48" 0. 48 O.C. 32" O.0 • 3/4"NciRay►'x�18'"�,�2�"O,,C���Sg"�'���;�48" O C�� 32"'OC,� =48"a',C>�..,�48"�'O C�= 4@"O�C�,; 7/8"d i a m x 18" 32".O.C. 8''O.C. 48" O.C. 48" O.C. 48" O.C. 48 O.C. 48" O.C. . . . FOUNDATION BASE SHEAR I . .. V bass.2 V 6ase_7 V ........ ..._..— --y- I - IF—CIF-20'-0"-->I T A .. - V_base_B---�..._. is -------=--------------------- " CONCRETE U . M-. SB r- V_bask_C—►_... - C .. - V_base_D—>... TT D I. 1 t7l- RSTA#6291 STRUCTURAL CALCULATIONS Sheet 40 of HAVEN HOMES (Stern Residence, , Greenport,NY) h-! Table 2C. Shear Capacities foir Horizonntal Diaphragm Assemblies;' Fra ning.Species .. Framing Species -Frahrhing Species G z 0.$0 0.50>G a 0.42 0.4' 0:35 W. Diaphragms Blocked '`. u Blocked }a Blocked. 1. o 0 - Panel Edge Nail Sp acingin. 62 6 4a 2Ss� 2a 6Z: 6 4a 2%za" 2° 62 . G 44 2/a 2a Sheathing Material Sheathing Nail Recommended Shear Capacity(plf)' Tlitcktiess. Size Structural I 3/8 8d 1801.270 360 530 606' 165 250 330 490 .5563 155 230 305 .450 510' I 15/32 lOd 215 320 425 640' 730' 200` 295 390 -5 - 6703 185 .270 366 545' G20' I Structural Sheathing 3/8 . 6d . 12S 185 250" 375 420'- .115 170' 230 345 3853 105 155 215 320 3553 8d 160 240 320 480 5453 145 220 295 440 500' 135 205 270 410 465' 7/16 Sr1 17.0 255' "340 505" 515' 155 235 315 465 530' 145 215 290 430 4903 , 15/32 8d 180 270 360 530 600' 165 .250 330 .490 550'° 155 230 305 450 310' 10d 190' 290 385 575' GSS' 175 265 355 530' 605' 160� 245" 325 4Q03 5553 19/32 lOd 215 320 42f G40':. 730' :200 295 'of' 590' .670' 185 270 3G0 5453 G203 f G'.. Spechfic:gravity of.fratning species '- or otwi d design,tabulated values shall be permitted to.be increased 49% 2 - - -. . Wheu panel•edges are staggered over common framing members and the load is raining to the framing members,tabulated values I stall'be permitted to be increased 33%. 1 - ' = Traming at adjoining panel edges shall be 3 inches nominal or wider and nails sliall be staggered. k a Nail spacing at.edges other than diaphraghn boundaries and conthihious.panel,edges parallel-to load shall De :pertrtitted to Ue.6 inches,4 inolics,and 3 inches I siea8 of 4 inches.2-1/2 inches and 2 inches res ectivel - •'. ' t i J Table 2C Shear Capacities.for Horizontal Diaphragm..Assemblies (Coat.) Sheathing Material Thickness Nail Dia lira of Material Size p �" "Nail Spacing(in.) . 1 Recommended Construction Rec m: Shear Capacity ( Panel Edges intermediate (pig Su oats Gypspuh Wallboard 1/2 5d Cooler Nails or Uihblocked 1-1/4.D wall"Serews 7" 10 70' LunhUei Sheathfny 5/8 or 3/4 8d Common Nails' Sttai ht.Sheathin 3 erSu oft 2 er Su "ort 1 50 . Die oral Sheathin 2 erSu ott • 2 erSu ort ,.� 300, •. Special2-Layer 2.per.SuppordLayer 2 pee Support/Laycr 600 I Dia oval Sheathin � Tabulated shear capacity can be increased to 90pif when ceiling-framing me hh6ers are spaced not more than 16 inches oil Center,per ICBO Report No.1,874 89 +\ST'1 L AMERICAN WOOD COUNCIL 4 /�5 SUPPLgMf Table 3B Design-Criteria fio Determine•, hear Capacities for Shearwall Materials, The shear iesistanec of wood"shearwalls shall be.computed�using one 'of two methods: . Method.1. Shearwall Segment Method 1 Limitations Thefollowin limitation -apply to the use:dMethod l Shearwall Segment Method - g a. ..A shearwall segmeritshall be located at each end of a shearwall. Openings shall be.permitted to occur beyond the ends of the shearwall,however the-width of such.openings shall not be included in the width of the shearwall. . .': U: Iaor:wind design,the shear capacity of shearwall segments sheathed on both sides with similar or disshnilar materials-shall equal the sum of the unadjusted shear capacities for each side. For seismic design; the shear capacity of shearwall segments-sheathed on.both sides.with similar,materials is equal to` i two trines the shear capacity ofthe side with the lowest shear capacityor the shear capacity of the side with the.highdr shear capacity. For seismic design . • gri,summing dissimilar materials is not permitted: c Shearwall segment aspect`ratios shall be limited to the minimum aspect ratio for the,sheathing material ...on either side of the shearvall. d '.`A shearwall segment shall not have out ofplane(horizontal)offsets Where out of plane offsets occur, Portions of the wall on each side of the offset shall be considered as separate shearwall segments. e ' Collectors for shear transfer shall:be`provided through the full length of the shearwall.. f Shearwall height,li, shall not exceed20 feet.. 2 Shearwall Capacity The total shearwall capacity shall be equal to the unit shear capacity,.of the shearwall segments tunes flier sum of the lengths of the shearwall segments. ;. Anchorage and Load Path. Design of shearwall an and load path shall conform to the requirements of this section,or shall be calculated using principles of mechanics 'Wail•fawning,sheathing,sheathing attachmcnt`Shall be in accordance with the requirements of 2.4. a Uplift and Anchorage at Shearwall Segment Ends Anchorage for uplift forces due to overtunung shall be provided at each end of each shearwall seg ment. The uplift anchorage shall be in accordance with 2.2.4 For each story the uplift force,T,shall be.calculated in accordance with the following: where . T—Vh T. _ tension chord uplill force(lbs.) V — shear force in shearwall.(lbs.) shearwall height(ft.) . Lr = sum of lengths of shearwall segments(ft.) b•;Anchorage for in-plane shear. The unit shear force,v,'transmitted into the top of a shearwall segment,out of the.base of the shearwall,and into collectors din calculated in accordance with the-following: g struts)connecting shearwallsegments,shall be where:" � . unit shear force(plf) V shear force in shearwI"(lbs.) �1 Li: sum of lengths of shearwall segments(ft.) it C.Corupression Chords Each'end of each shearwall segment shall be designed for.a compressiou.force,.0 ! equal to the tension force,T,calculated iu Item 3a(above):. � j d.Load Path..A.load path to the foundation.shall be provided for each uplift force,T and t,:for each shear ! force,v, and for_each compression force,C. Elements resisting shearwall forces contributed by multiple stories shall be designed for the sumof forces contributed by each story. AMERICAN NOCQNCIL U RSTA # t "A �Z� WOOD FRAME CO�STRUCTION,MANUAL 275 I Method 2:- Perforated Shearwall-Method Limitations The followuig limitations apply to the use of Method 2=Perforated Shearwall Method a. A perforated shearwall segment shall be located.at each end of a perforated shearwall. Openings shall. be;permitted to occrir beyond'the'enda.of the perforated shearwall,however the width of such openings I shall not be included in the width of the perforated slearwall b: -Wails.-shall Ue'eiitirely sheathed with structural sheathing;including the areas above and below windows and above doors. Areas above and below windows and/or above doors shall be.permitted to remain -. 1 unsheathed if the unrestrained opening height is assumed to be the height of the unsheathed opening. ' c, For.wind design,the she capacity of shearwall segments sheathed on both sides withsiinilal or dissimilar materials shall equal the sum of the unadjusted shear capacities for•each side. For seismic design,"tile-shear capacityof shearwall segments sheathed on both sides With similar materials is equal to two runes the shear capacity of the side with the lowest shear capacity, or the'shear capacity of the,.side.. with.tUe higher shear capacity.. For seismic design,suuulung dissimilar materials is not Perin itted' d. Sliearwall as segment ect ratios shall be limited to the minimum aspect ratio for the sheathing material g p On either side.of the shearwall.. e.` A'perforaled shearwall shall not have:out of plane(horizontal)offsets Where out of plane offsets occur, portions of the wall on each side of the offset shallbe considered as separate perforated shearwalls. ' f. Collectors foi shear transfer_shall be provided through the full length'of the perforated shearwall._ g. :A perforated shearwall shall have uniform top of wall and.bottom.of wall elevations. Perforated shearwalls not having uniforiu elevations shall be designed by other methods. h. Perforated shearwall height,.h,shall not exceed 20 feet.,: The unadjusted shear capacity of the shearwall shall not exceed 800 plf. I � I i 2 Percent Full Height Sheathing. Tlle.percent of full height sheathing shall be calculated as the siiru of widths j ! of perforated shearwall segments.divided,by the total.width of the perforated shearwall including op.ening3. s. ' f .. Ivlaxlrrium Opening Height Ratio. The I11axrinum opening height shall be taken as the maximum clear i. opening height , 4 Adjusted Shear Capacity. The_adjusted shear capacity shall be calculated' multi 1 Y p ying the unadjusted shear capacity by the shear.capacity.adjustment factor in the table below: For intermediate percentages of fiill heiglit sheathing,the values in the table below are permitted to be interpolated. Shear Ca aci Ad'ustment.Factor Ivlazimum Unrestrained Opening Height I Window Height Door Height II/3 H/2 2H/3 5H/6 FI i g'Wall 2'=8" 4 3-4" 6'-8" 8'-0' _ 10'Wall, 3'-4" _ 101_0.. Percent Full - Shear ear Capacity.Adjustment Factor Height Sheathing �I 0% 1:00 0.67 0.50 0.40 0.33 . 10%` . . { ...00 0.69 0.53 0 43 0 36 20%•: 1.00 0.7.1 0.56 6.45 0.38 1 I 30%. 1.00 0.74 0.59. 0.49 1..00 . 0.4T40% 100 ;77 0:G3 ).5350%. 0.45 0.G7 0.G / 0.83 57 0.50 080 II 0.71' 0.63 O.SG 70% . j I.00 6.87 0.77 0:69� '0.63 I 80% ` 1.00 0:91. 0.83 0.77 0.71 90% 1.00 0.95 0.91 0.87' . 0.83 i 100%... 1.00 .11001.00 1.00 AMERICAN.FOREST&PAPER ASSOCIATION SUPPLEMENT " 5. Perforated Shearwall Capacity.:The perforated shearwall capacity shall be equal to,the adjusted shear ;.. capacity;tunes'the sum of the widths of the perf€�iated shearwall segments 6 Anchorage and Load Path Design ofperforatedshearwall,anchorage and load path shall eonfoun to the requirements of this'section,or shall be calculated using principles of mechanics. Wall framing;sheathing; : sheathing attachment shall be iu accordance with the requirements of 2.4 a."Uplift and Anchorage at Perforated Shearwall-Ends. Anchorage for uplift forces due to overturning shall be provided at each end of the perforated shearwall. The.upliff anchorage shall be in accordance with 2.2,, Fot each,story the uplift force;T,shall.be`calculated in accordance with the following: �- _ (CoELJ T Vh/ wher e T - tension chord uplift force(lbs) . V sheaf force in Perforated shearwall lbs p ( ) h shearwall height. Co shear capacity adjustment factor from Item4(above) I sum of lengths of perforated shearwall segments b.Anchorage for In Plane Shear: The unit shear force;v,transmitted into the top of a perforated:shearwall, out of the.base of the perforated shearwall at full Height sheathing,and into collectors(drag shuts) connecting shearwall segments;shall be calculated in accordance With the following: v=.V/ C L where. . " J v = unit shear force,(plf), V = shear force in perforated shearwall(16s.) . Co = shear-capacity adjustment factor from Item 4(above) YL� = sum of lengths of perforated shearwall segments(ft.) c.Uplift Anchorage Between Perforated Shearwall Ends. In addition:to the requirements of Item 6 (above),., perforated shearwall bottom plates at full height sheathing shall be anchored for a uniform uplift force t , equal,to the unit`sliear force,v;aeteirnined in Item 6b.(above) - II d. Compression Chords: Each end of each perforated shearwall segment shall be designed for a compression force, C,equal to the tension force,T,calculated in Item 6a(above).. e.;Load Path A load path to the foundation shall be provided for each upliftforce,T and f,"for each shear force,v,and for each compression force,C. Elements resisting shearwall forces contributed by multiple stories shall be designed for the sum of forces contributed by,each story. 1 . p " ' A I MER CAN WOOD COUNCIL . 06D FRAME CONSTRUCTIONMANUAL 277 Table .. , 3C Shear Capacities for Shearwtill Assemblies Framing Species Framing Species Framing Species G z 0.50 0.50>G a 0.42 0.42>G z 0.35 - 1 ` Panel Ed a Nail Spacing(m 1 G 4 3 2z `6 4 3. 2z 6 4 .3 2z I Shcathui g Mateiinl IvLmmum> Nail (Plfl� Sheathing Size' + I Shear Capacity i m Struchunl1` 5/1.6; " ' 64 200 300 390 510 185 275 3G0 470, 170 255 330. 435 II 3/8 8d 230' 360' 460' 6104 230' 3G0` 460° GIO° 230° 3G0° 460° 610" 7/16 8d 255'. 395' S05' G.70� 255° ,395 505 G70 240 365' 470 620 15/32: 8d 280 430: 550' 730 .260 395 5053 670 240 365 470' G20 lOd 340 510 .665' 870' .315 470 .610' 800 290 ,435 565' 740 m Stmctural She�tliing, 5/16 6d 180 270 350 450 165' 250 .320 "415:. 155 230 300 385 trt Plywood Siding' 3/8 6d 200, 300 390. 510 185 275 '360' 470 170 255 330 435 -oil 0°! 220' 320° 4104 S30° ^�I 8d 220° 320' 410° 53 220 320 410 530 7/16 8d 240° 350' 4504 585' 240 350. 456 5851 220 325 415 545 I 15/32 8d 260 380 '490' 640, 240 350 450' 590 220 325 415' 545 1Od 310 460 600' . 770 285 425 550' 710 265 390. 5]0' G55 I 19/32 lOd- 340 510 665' 870 315 470: 610' 800 290 435 5653 740 I } Plywood Siding' S/16B:0 140 210 275 3G0 130 195. �25,5] 30 120 i80 235 3053/8 160' 240 3103 410 140 2 O0 375' Y35 205. 2G5' 350 i G - ;Specifie gravity of framing species ;.For wind design,tabulated values shall be permitted to be increased 40%. i z r Frfuniug at adjoining panel edges shall be 3 inch nominal or wider and nails shall be staggered where nails are spaced 2 inches O.C. ' Framing at adjoining panel edges shall be 3 inch nominal or wider and nails shall be staggered where lOd nails having penetration l into fiatning of more than 1-5/8 inches are spaced 3.inches o.c.. ° Shear values maybe increased to values shown for 15/32 inch'sheatlung.wigi same nailing and framing species provided(1)studs are spaced'a maximum of 16 inches o.c.,or(2)ifpnnel8 are applied wnhlongAiniension across studs. i s Conunon or galvanized box nails unless otherwise noted i. 6 Galvanized casing or-siding nails., ' Thickness at Point of nailin aloe anel ed yes governs shear values- f I � i it AMERICAN FOREST&PAPER ASSOC1ATION I I - 278 SUPPLEMENT . :Table 3C Shear.Capacities for:Shearlrail Assemblies (Cont.) g. astener Wall Construction Panel Edge Nall $hear Capacity Sheathing Material Thickness F ' of Material Size Spacing Cellulosic Fiberbor d 1/2 Gd Blocked 3 125 Sheathing-Re ular! Cellulosic Fiberboard 1/2 8d or 11 gage,.. Blocked 3 125 Sheathing-Stnrcturali galvanized roofing nail,14/2""long,;: ! 1/16"head. 25/32 .8d or 11 gage Blocked 3 :175 galvsnizedxoofmg I I ' nail,1-1/2"'long, 7/1G"head Woven or Welded Wire Lath 7/8 11 ga.Screws or Unblocked G 180 and Portland Cement Plaster LG a:Staples Gypsum Lath,Plain or 3/8"lath 13 ga.,Plasterboard -Unblocked Perforate dZ and 1./2' Nails { Plaster 2'x8'Slieets 1%2` I1 ga.Nails,1-3/4 Unblocked .} I Gypsum,' long,7/16"head f ! 75 Sheathing ' ]3oardz 4'x8'Sheets 11 ga.Nails,1-3/4 Unblocked' j 1/2 long,J/16"head 7 100 { Blocked. 4 175 I �- Gypsum Wallboard I } - i _ - uol 1/2 Stl Cooler Nails 125' Unblocked 7 ' 4 Blocked it 7 ;'125 4 150 ' Gd Cooler Nails Unblocked 7 115 'I } 5/8 Blocked 145 4 4 175" ' Base ply-Gd Two-ply Blocked Base ply .9" 250 } Cooler Nails Face ply-7" a Face ply-84 Cooler Nails Lumber Sheathiu 5/8 8d,Common Nails. Sttai Irt Sheathin 2 er Su ott 50 Dia onal.Sheathiu 2 erSu ort I 3U0 I . Tabulated she capacities are for short term loading due to.wind or seismic loading in Seismic Design Categories A,B,.or C. Values shall not be permitted in Seismuc Design Category D,E,or P.. z Tabulated shear capacities are for short term loading due to wind orseishnc loading in Seismic Design Categories A,B,or C. Values shall be reduced SU%in Seismic Design Category D. Values shall not-be pernitted iu Seismic Design Category E or P. She tt capacity,is liased on maxhuum£ranting spacing of 16 inches o.c.,for framin spaced at 24 inches o.c,values for 7 inch and 4 inch nail spacing shall be reduce to 75 plf acid 110 plf,respectively, g . Shear ca aci y is based on maximum framin s acin .of 16 inches o.c. �'r AMERICAN WOOD COUNCIL `f��5S ' A 62 1 , I � LSTHO/STHD Strap Tie Holdown l ; '® t This product Is pre/eraL/e to shn/lar connectors 6ecanse of nJ ea s/er lnstallatt o, r•3�►I j ' .bJ higher loads,c)lower Installed cost;or a comhlnatlon of theso leatrires. I The.9THD is an embedded strap tie holdown with high load dcapacity and a staggered nail pattern to help minimize splitting.The latest version of the STHD strap lie liaidewn incorpuralos many now features that impiove installation and(auction. When used in conjunction with till StrapMale�you liava a system that helps prevent J hallo parallel and porponilicular movamont during installation relative to the farm:. STHD I Allows for accurate lecaliutt of lho STHD's and reduces the possibility of spallingl L M.Patens Nails are countersunk FEATURES. - 5,813,182 for a low profile The strap nailing pattern allows for nailin to the ed es of double 2x's. strap surface. g 9 U..- •A slot below the embedment line allows for increased front to back concrete i bond and reduced spilling. . I a 4 Strap nail slots are countersunk to provide a lower nail head profile. Him joist models accommodate,up to a 17-clear span,without any loss of strap nailing. qh• MATERIAL:LSTHD8 LSTHDBRJ-14 ga,all others-12 ga. FINISH:Galvanized, Embedment. ' INSTALLATION: •Use all specified fasteners.See General Notes. . We Nnaeo ' •See Post Tension-information on page 43: (Top of. 4xPasr� POnTION y i •Install belore.cotcrete pour with a SlrapMate,or other holding device, concrete) le NAILS SIMILAR •:Nail strap from the bottom up.Strap may tie beef one hilt cycle. 116, END DIST •Bending the strap 90'to aid'wall placement may cause spalling behind the strap. If the spall is 1'or less,measured from the embedment line to the bottom of ' the spill,full loads apply.For spans between 1'and 4'(see ttlustmtlonJ,the f allowatilo.load is 0.90 of If table loads:Any portion of the strait left exposed STHD' a !4 -4h• should he protected against corrosion. STHDI0;STHD14=4W-5%a' + •For two pour-installations spelling is measured from the first pour. •Where fewer fasteners are used in the structural wood member,reduce loads °":uvEan according to the code. 30'MIN. REeAR FlEOM t IN SHEAR CONE •Unless otherwise noted,d0 NOT hlstall where:(a)a horizontal cold join exists LENGTH within the embedment depth between the slab and foundation wall or footin flERAn`F •• "6k!"- FROM �LENGTfV beneath,unless provisions are made to transfer the load,or the slab is g coRNE ' ; designed to.resist.the load imposedby the anchor;or(b)slabs are poured over concrete block foundation walls:. Typical STHB14RJ •To get the full fable load,the minimum center-to-center spacing is twice Rim Joist Application the embedment depth.when resisting tension loads at the same time: t There is an increase in file amount of deflection if the strap is installed on the outside of file shear panel Instead of directly to the framing. I' Ask fur Form T PLYWOOD for complete details. Typical STHD Edge Installation •FOUNDATION CORNERS:Nall quantities may be reduced for less than le comet (for two pour,see lnolnole 5.J j distance design loads—use the code allowable loads for fasteners in shear. •To tie double 2x members_together,file Designer must determine file fasteners required to bind members to act as one unit without splitting the wood: . Additional studs attached to the shearwall.studs or post may be required by rnr?�"fp19 the Designer for wall sheathing nailing: 2x Embedment Wood shrinkage after,strap Installation across horizontal members may • 3l Length+12' cause.sirap to buckle outward. Min.Rebar Length CODES:See page 12 for Code Listing Key Chart. i F� f I �• i 4 Model Np ,rt11i. (L) r i l! - , ibFita z INa I is�tl ' r��)�!' ;,� x I p+�1 , 1 �'� 1 � "i f ,��•.fv f lyiothl k+.i i`F ' r �. i , Ref. �) l LSTHD8/LS I VIDBRJ s 6 21/a 35/Q: 8 24-16d sinker 1695 1695 1695 1825 1825 1825 +1950 .1950 1950 STHOB/STHD8R' 6 21% 35�/a B ° 24 i6d sinker 1760 2050,' 2345 1950 2210 2385 2135 2370 2425 �. ; STHD10/STHD1"DR( 6 2Syb 366/0 '. 1 32,12'I d: STHD74/STNtl:1�pJ... •G 31s/s '° 39 u. :,-I t `�3.��9 stirk8 f LSTHDB/.LSTHDBRJ 0 21'/e 35Yo 8 24-16d sinker, 1695 1695 1695 1825 1825 2335/ �1950 1950w.297511 ® I. I STHDB/STHDBRJ D 21% 24-16d sinker" 2370. 2370 3195 STH01tl75Ti1D vi''' $ i r3 9 s 32,28, 2370 2370 3195 2370 2370. 3195 122 t . �1.`r t� �3�j� J9®e :r1 t• k$"'�" m` ' 'r 9 ' e } IS s s 4jA sin 'A' 1.'RT aftor lite model Indicates STHDs for rim Joist applications e g STHDBRJ - !* 2:STHDI4RJ on 0'stemwall requires 30-16d sinkers,with the(to)load at 1336/6 of 4960 lbs." 10.Post design shall be by Oesignor. J 9:STHD14 and STHDI4RJ Installed on HF/SPF In an 0'stemwall:the le load is 5280 lbs. 3.10d commons or 12d common nails may be used with no load reduction. 4.Minimum nail and distance to prevent splitting is 10 x diameter,1lh'for led sinkers, inslaI ad as shown De page 43. 11.Loads shown apply to post illusion slabs when ono#4 rob (minimum)Is 10d common and 12d common. 5.For two pour with 4'-slab or less.The STHD14 load at�'A'ond'distance 2000 psi is and inlormalion. 12.NAILS:16d Sinker.0.148"dla.x 3'/a"long.Sao page 16-17 for olher Half sizes I , 3235 Ills.and 4220 lbs.at 14'end distance.The STHD10 at file same condition is 2035 lbs.for yz'end distance,and 2750lbs.at 10'-end distance. 13•STiID14 anti STHD1g allowable loads for an End inslallalion Condition(Not a Comer)a1 G.Allowable loads have boon increased for earthquake or wind load durations with no MV end dislanco,6-inch stem wall,2500 psi connate,are n Co and 1U(N ills Cr)itrespectively. further Increase allowed;reduce where other lgad durations govern. 14.STtID14 allowable loads for an end inslallallDn,0-Inch stem wall,2500 psi concrete, 42' 7.Strap may be bent one full cycle.(front horfanntal99•lion GeM vertical.) /s"and 1'/,'end distances era 3845 and 420g lb rospoelivofy, j 8.Calculate loads usin stral hl lino.Inter elation for corner dlstancos blilween/z and I. } g g p 15.STiID14 allowable load for an and Installation,l0-Inch stem wolf,,/,"end distance and I 0 2500 list concrete Is 45OU lbs. 01 WN t � STHD's require a mInimum of . $PALL REDUCTION SYSTEM 1 n nd distance FOR STHD STRAP TIE HOLDOWN w -he multiple 2z , members are used as shown < FEATURES Spilt-ln tab. ONE/4 StrapMatO locator line. SHEAR 1N Additional diamond hole_ m RJ versions . SHEAR CONE _ '' � -� $M1, 12'MIN: 12'MIN. REBAR LENGTH REBAR LENGTH BENEFITS l .. . Built-in Tab: ((�- Reduces spaliing and costly retrofits Sao: a o d ' I labor fdInstall. Q M1111 ' E Ni r M!N REB R' r. f •Holds STHD away from form board - Ap �o LENGTH ENp .r' ..-'.. LENGTH:..-• !' .. -, DISTANCE S1rapMate Locator Lin ,. . Easy inspection;to ensure proper location a ' •Allows adjustment without removing 1 STHD 4 Typical STHD SPALLING LOAD REDUCTION! Addltlonal Of Hole:. a Corner Installation If strap is bent horizontal 90'during One more fastener to help i on 3-2x studs Installation,and then bent vertical(bent STHD RJ models from bowing out at the (for two pour, one fell cycle)for nailing to the stud,:' rim joist section see footnote 5.) concrete spaliing could result..Load • - .. reductions.May apply, see installation note. .• STRAP I STYLE STRAP HOLDOWN - HORIZONTAL STYLE ,.HORIZONTAL'S PROJECTION HOEDOWN. PROJECTION OF.EMBEDDOED.. OF EMBEDDED — PORTION PORTION OFSTRAP HOEDOWN ::.. OF STRAP. HOLDOWN 4'SLAB LOCATE ONE- LOCATE ONE - r w L r'' ''°° - '�` I4 REBAR WiTHIN /4 REBAR WITHIN I .id I�6 '•^ a HATCHED AREA HATCHED AREA MAY BE .. --CONCRETE'—► FOUNDATION ` CONCRETE FOUNDATION REBAR). " - FOUNDATION REBAR) FOUNDATION DOES NOT NEED TO FQD BY OTHERS * BY OTHERS *E TIED TO REBAR SPALLING. ' J REDUCTION S NR Vv _ N. OM I ND Single Pour Behar Installation Two Pour Behar Installation" OFCDNCBETE i *Maintain minimum rebar cover,per 'Marnlaln mtnimurn rebar cover,per ACi 318 concrete code rertuliemenls. AC1-318toncrete torte requlremenls. Typical STHD14 Typical STI-ID14 End instalfallen it Two Pour Installation (No corner return). .� Z _ W INFORMATION Z i, z ntlgw�l►le I Post Tension ;� , MdtiRl bif`oence° it t ; Uplift Cade Cable Placement No : fn Fasiobots . _In a Garage • { porger ;. . '•i193) fret Fooling:.:.. r n �: U: y HPAHD22 /z:Min 13 16d 2705 t s• Yl` : 8'Min 23 16d 4570 124 II o ( Curb Width r—� � -�_ L$THD6!'' '/?'Min 4•i6dslnkets 1695 2j. e _ t<� fjbl3A 8'.%Mtn 24�16 .aipkeFs. 1695112 0'1 h• M Typ..' STHD8/'- M Min 24-16d sinkers 2055 �, -• STNDDRJ 8' Min 24-16d sinkers 2345: 32 Top View of Post Tension , 28 STHD10/ /2 Min 28 16d sinkers 2055 122 Cable Placement II I ti' : •• STHDI ORJ . .10'Min 28-16d sinkers 3185 HAIRPIN TYR I 1.Minimum concrete strength Is 2500 psi. { " 2.Post-tension sleel.is minimum IN dlameter,1-wire,low-relaxation (. +oil+ a• strand In accordance viith ASTM A416,Grade 270 ksi,with a i .:�•- 1 , guaranteed ultimate strength of 41.3 k. I, DETAIL 1 A PosrTENstoN DETAIL 2 3.Anchorage Is monostrand-t a anchor system with currant ICC When Installed ana *`;: ' r7';c;> TENDON,nR YP OPTIONAL Pohl Tension approval using a,ductile Iron casting DI at least 2.25'x4.5 of bearing raised curb,use 6" ; �, coLDJOINr Cable Placement and reusable packet formers on all stressing ands. $temwall installation ,;. ,!: PNCHOR,TYP. Corner Installation .4.It Is the Designer's responsibilliy to provide reinforcement to lie cold•olnts' f ANCHOR,TYP J and loads(pogo 42) Elm I a�,�ppgg' and to.resist bending stresses In the foundation duo to anchor uplift. { ' gbh.,t>rs ail! ��1 ✓D tlf� 5.Post design shall be by Designer. •.ra fu 6:NAILS:16d=0.162"dia.x 3'/2"long,'1011 sinker d 0.140"din.x 31le long. ? Soo patio 16-17 for.other nail slzos and lurennalien. �. /-7 i; CODES:See page 12 for Code Listing Key Chart. -------------- Available wlfh additional corrosion protection:Check with factory. ' BEAM ana- 6v:-STRAP l Dimensions Fasloitfirs s�,3 t 1 �)131 i' _ } 2�e Modei.. �h toil i S r, t END Ga. �Y6(1�} {; �. t Citd♦Y DISTANCE' W L Nails LSTA9 1'/a 9 8-10d 645 775 555 665 = , . LSTA12 1'/4 12" 10-10d 805 970 695 830 LSTA15 1'/4 15 12-1Od 970" 1160 830 1000 LSTA18 1'/a 18 14-10d 1.130 1235 970 1165 7,G2,90,.128 . LSTA21, 1Yn 21 16-10d 1235 1235 1110 �1235 LSTA24" 20 1?/4 24 18-10d 1235 1235 1235 '1235 ST292 2'/1s' 9%1e 12-16d: :1120 .1265 970. 1160 TYPical LSTA Installation. (/ranger not shown) i ST2122 2'/,e. 1213/,e . 16.16d. 1505 1535 . 1290 1535 3,28,39,80, Bond strap,one time only ST2115 3/4 16e/,a, 8-16d 665 665 665 665' 104,121,128 ST2215 21/1e -165/,e 20-16d 1880 1800 1625 .1880 45T 30 1?/a. 30 CST 36 1?/a :: 36. t.. •? @Qf1..: #",::E3 7,62,90,128 BEAM and ter' STRAP. - LS`149 33/4 49 9,121,128 /�� L TrI7 3J/;r 73 48 :'/e0 - 3J5 9,128 2 '� " BTA91II. 1'!AND 9 ' i `i 0II.0 •• DISTANCE lip 'M$TA12 7,62,90, I } •MSTA15 1'/a. 15 r .,. .,)0d :>r �' i 1420 123,128 Ala 11/.i:• 18.° iOcJ`. s E( , iia5°: II "MSTA21 ' 1:,/a 21 I �i 1 5O% ' MSTA24 1'/4 24. 1 •10d 3 •l�. 4: 1525';. . MSTA30. 1?/4 30 22:10d 1II35 2050 1585 1900 7,62,90,128 MSTA36 I Y4 3G 26 10d 2050 .2050, 1870 2050 ST6215 2%1s 1.Go/,o 201Gd 1895 2095 1640. 1970 3,28,39,88, fiypical:LSTA Installation L i ST6224 2Y10 235/,c 28-16d 2540 2540 2315 2540 104,121,128 (hanger not shown) i ST9 1'/4 9 8 iGd 755 910 655'' 785• 3,39.88,104,121,128' Bead strati one[line only ST12 16 11/4 '115/0 10-16d 945 1135 820 985 ST18 - 1'/4 1734 14 16t1 1325 1420 1150 1380 3,$9,88,' ST22 ;11/4' 215/a 18-1Gd 1420 1420 1420 1420 121,128 MSTC2II 3 2II'/4 3G 16d sinkers 3000 3600 .2590 3110 9,23,121 t28 MSTC40 3 " 40'/4 52-iGd sinkers 4335 .4585 3745 4495 MSTC52 3 52'/4 62-16d sinkers 4585 4585 4465 4585 23,128 " ' M aleF al i 6 de( Tlflal(fiets' 01 Boll§;;' Code 1 y liar. t. . y HRS6 6 11/0'-3 63/A20,39,88,104,121,128 PS2188 171 mil 2 18 �I 3/4 _. 6 10d 525 630 455 545 PS4188 (7 9a) 4 . 18. .4 3/a 180 0 off" HRSB 13/e 8 1010d 875 1050 . tbu _ 910 128 PS720 63/4 20 y 11RS12. 13/e 12 14 10d 1225 1465 1065 1275 1 — " FHAG: 17/10 6Yo 8-i Gd 2 810 975 . 705 845 ti FHA9 1r/m : "9 8 iGd 810 975 705 845 . I ��— r o !!.. FHAl2 17/�s 115/0 8 1 Gd - 810 975 705 . 845 T a FHA18 12. 11/1a 173/4 81Gd 810 975 705 . 845 w FHA24 1'/,0 23�/0 8 16d ` 810 975 705 845 FHA30 1 r/io 30 8-1 Gd 810 975" 705 ` 845 3,39,88, ' t -MST126 2'/m 26 2G-10dx1'/z . 2355. 2830 2045 2455 121,128 PS218 and PSate 2n 1v. = I MSTI36 2%e 36 36-10dx1'/z 3265 3915 2830 3400 PS PS720 a ' ''2• 8 MST148 2Yio :48. 48-10dx1'/z 4350 5080 3775 4530 MSTIGO 2Ym 60 60-10dz1'/z 5080 5080 4720 5080 N ' MST172 21/ia 72 64-10dx1'/z' 5080 5080 5080' 5080 3,39,121,128 ra i 1.Loads include a 33%or GO%load duration IncLse on the fasteners for earthquake or wind loading, 3 bill DO NOT Include a.33%stress increase on Ilia stool capacity.Refer to page 13.for further explanation. 2.10dx1'h'nails maybe substituted where iGd slnkors or lud are specified al luu%of file table loads. 1, i 3.1 Od commons may be sUbAltutod where 1 Gd sinkers are specified at 100%of table loads. 4.iGd sinkers(0.140"dia.x•�1/4"IQn9)or loll commons may be substitute'd where 1Gd commons are specified at i 0.85 of the table loads. ;. 5.Use hall of the Halls in"each member being connected to achieve the listed loads. G.PS strap design loads must be determined by the Designer for each Installation.Bolls are installed f both perpendicular and parallel-to-graln.Holo diameter in the part may be oversized to accommodate the HDG.. Designer must determine if file oversize creates an unacceptable Installation. 7.For overlap splice details,refer to T-CMS/: . 0.Straps with 100(0.148 ilia,x 3)nulls specifled may be subslituted with 10dx1'/z(0.148 dia,x 1'/z)with no redaction in load. 156 9:NAILS:loll=0.102,,dla.x 3Y21'long,iGd Sinker=0.140"dia.x 31/4"lung;lUd=OA40"dia.x 3"long. Typical PS720 Installation 1Odx1'/2=9.140"ilia.x 11/z"Iong•San lingo 18-17 for other nall.sizos and Information. � I Floor-to-Floor Clear Span Table". ! °d'Motlel Clear ,- Fasfenera,,r e + e S AIIAWa �q.Tgn$ia NatlS are STrrcH NAILING ® l �l r No. Span T lal`.:; ,1 S�I' i Lo`ads h�P $ �" " not required .:I R .,), OF DOUBLE STU05 133), I (160 in the rimByOTHEns 1'8 ` 12 1sd sinker .1000' 1200 865 1035 board area. L: .16 16-116d sinker 1335 1600 1150 1380 L M5TG.40 18. 29-16dginker w 'rr ns 201$ 2420;. MSTC52 18 44-16dainker 3665 4400 3170 3800 16 48-i6d sinker 4000 4585 3455 4145 When nailing ; 116 64 18 the strap over M5TC66 S OSB/plywood,use Y6 68,10d'sifll{ 10d commons f . MSTC78. 18 76 16d'sliiker 5660• 5660 5660 5660 i6d sinkers, 16 76 i6d sinker 5660. 5660. 5660 5G60 16dcommons S - MST37 A minimum 2010,, <241 penetration of iD 32-i6d 3370, 3695 2925 3505 . 10 nail diameters :. MST48 16 34-16d 3580 3695 3105 3635 is required far 18 96-:18d : ;: table loads r, Floor-ta Floor Tie �MST60 n :qd4 ?iQ,� cat See note 3 for Installation 16 ' Q6-•16d 1l x,> Qp; load reductions.. showing MST72.: 18 46-i6d 4830 4830 460U 4830 a:Clear Span 16 48-,16d 4830 .4830 4800 4830 '18' 1A fOtlxlJz :. .. !11QI1 z 1.3 , y MST136 `' 16 . 16-10dXi tli•=. i ` � . Typical,Detail.with Strap MSTI48 18 : 26-1Odx1'/z 2355 2830 2045 2455 ring CODES, Installed OverSheatl 16 ' .28-10dxl'/z 2540. 3045. 2205 2645 See page 12 for Code Listing 18 38 10dX1 y4 ' i 'a ? g l Loads include.a 33°/a or 60"/°load duration I IMSTI60 .T;3G8 Key Chart, Increase on the fasteners for earthquake or i 1G.. '10.10 X(1.','• 2. ? ,Da yE'. wind loading,but DO NOT include a 33% MSTI72. 18 50 10dx1'/z 4535 5080 3935 4720 stress Increase on the steel capacity. I ' 16- 52-1Odx1'/z 4715 5080 4090 ggig ® Available with additional corrosion Refer to page 13 for.turliter explanation: ' protection.Check with factory. . 2.10d commons maybe substituled where ? _ 16d sinkers am specified at 100%ofthe I Dlmens)ons Fa il9n�rs(Total} p t 1110 a T table loads. = .Model ` r�l t 5, )e hp�100`I¢� r 3.16d sinkers(0.140 dia.x 3'/d'long)or 10d 1 OG)I `.• y( ,, iiF ��� s,,9 3 Cetla commons maybe substituted where. commons are specilled at0.85 of the table loads 1 4.Allowable boltloa8s are based on parallel to 11Y:;Ilia F a ' ,� 1,;. t ,, : k :grain loading and these minimum member 30 161 4 1/2 .3140 3770. 1800 2165 2740. 3290 1665 2000 thicknesses:MST.-2+h';HST2 and HST5-4 MST37 '12 2'/,e 3T/z 42-i6d G .'/z 4395: `.5080 2525 3025 `3835.'_A605 2335 2805 3'39+ 5.Use half of tHST3andHhe required nails lit each member. ;.MST48 2'/,a 48 46 i 6d 8' '/z 4845 5310 3065 3675 4200 :5040 .2840 '3410: :88 121, being connected to achieve the listed loads. i $TDO p 2'i$ :(3ij ;I6 + 1 ;� 128 6.For overlap splice-dotails,refer to)T-CMST. + 3,39,121,128 7 specilled with .l 10da substituted with 11ls 0dx1'/z I - HST2 2'/z 21'/4 - 6 6/e - - 4350 5220" - 4030 4835 (0.148 dia.x 1'/s)with no Fednclton In loan HST5 7 5 21'/a - 12 8/e - 8875 10650 - - 3,39, e•NAILS:1gd-0.162"dia.x 3y/z'long, 8225 9870 i6d Sinker=0.148"dia.z 3'/;'lont I{ r'1HST3 3 3 2 'h k. 6 �j f i 88,121.` i0dx1+/z=0.140"dia.x l'/z"long.J + Sea page 16-17 for other nail sizes �z i, and Information. . f ': A high value seismic tie for horizontal ties across Intervening mem4ers. FINISH:Galvanizedwig ::INSTALLATION: Use all specified fasteners.See General Notes. o• May not be suitable for floor'dtaphragms which protrude above,beams, m Typical HSA l CODES:Soo page 12 for Code Listing Key Chart. Installation. . ,. s>.:f Tptal]*aglenel;R � k ^ AI�W Idg), �Sr,.•. t; �,'I • ,•},Jedel�4 Strap +.lr ,` r, ' ,�}„ i.. llgdla 9 a°°% F}}},,'r , , HANGER NOTSHO`="M .. + • .a,-,...�. ...,1..-_ '�a.'� ";3;Y'1:''c,`ih','1°'''.�i4�f,�ts it^,'S('n�l� '...Y�� Y )!n. � 1,Sj - ¢ . 1900 1605 190Q y r.9 , : /C4 i .ga �, � + � � ��*?�� i tM);Ui �t�e d a( + •t; 3,39, "�c9 88,121 s,iuP e HSA59 3 ga x 3 59 - 8 3/4 - 6940 833a HSA68 3 ga x 3'/z ' 68 - 10 a/� 8350 I.Allowabla loads have been Increased 33%and 4.0nIySA36.can be field.lient for other I 60%for earthquake.or wind loading with.no further " Intermediate beam Widths. Increase allowed;reduco where outer loads govern: 5.NAILS:led=0.182"dia.x 3'/z°long 2.Allowable loads assume a restrained member r See page 16-17 for other nail sizes and Typical SA Installation ' Of 3'/x'min.thickness with bolts In single shear. Information.. 3.86.1t and nail values may.not be combined.. with,Saddle Hanger 157 Avallab/e with add/tlonal corrosion protection Check with factory.,:. - p - Madal HF lilt t k '- �r�l: `'li' , Hi 11) G Bdxl1/z 4 pd 990 C' 51R). .',485 165 455, 411 400 415 140 370 2,40,82 H25A? jB 4rlr 6�ed 'ri 5i lst tY T (. 121,140 'f�j' ''FM1!•tr 1 A y r . '.1� >FIt?.5X',. 1B " Bd" �' r'•..f$ r ..r+g"_. '¢p 1 0ri''f�tl e-r ftl�(1°r 40,122 .. 4 8d H4 20 4 8d 4 8d 455 455 0 - 415 320:: 320 ' 165 140 290 2,40,82,121,140 125 1 G 1 '.360 360 165 160 -380 235'> 235 140 ' .135 235 2,40,2,12 ,14 xr J 3A= d r 140 i 6 4 8d '2.6d 930 985 400;. ~ . — �. b 10dx1'2. . 5-10dx1/z — 800 845.. — 121,140' ' 620 745 . 75 ' — 530 585 75 H9KT ,18 4-SDS'/4x11/x 5 SDS'/4x1'/z — 875 875 600 125 125 H10 I ;r18 6 8d7f1'/i :.+ tti 8rd1F1� y`� ry 7 _ 55: 755 680 125 170. 9,321 H71Z 18 6-16dx2'/z 4 6-16dx2%z 5 }% 4tlr 8,121. 830 830 525 760 715, H14 .16 0 12-8dx1'h -.13-8d — — 1350 '1350 265 715. :;45D 655 ' 1050 1050 480 245 02 12 Odx1/z 15 6d 1350' 1350 515. '' 26a _ r 1 70 . 1:Loads have been increased 33°/and 60%forearlhquake or wfndloadm 1050 1nRn 480 245 0 shall.be copsidered.where there may b 1 25 ' no with able,l ad Increase allowed;reduce where other loads govern 5.Hurricane lies are shown installed on the outside of the wall grain clarll'ltInstallationotension. 2.Allowableaoads are for one'anchor.A minimum rafierthlckness of °is acceptable.For uplllt Cont nuous Lpad Path;connectlonsan the seine.area on Ills Inside of the wall 2W must be used when framing anchors are Installed on each side i of the Joist.and.on.tha same side of the plate(exception:I/z.5A.` plate to sht, must be on salve side of the wall. ( lrrrss!o/ilale and- of Southern Pine allowable loads for H14:146516s(133/160),560'Ihs(Ft Lateral 1331160)and ' .3.Allowable'uplift load for stud to tioltom plate lnstallatlon is 4001bs. (H2.5);390.lbs(H2.5A);360 lbs.(H4)and 31.0 Ibs(HtS). 285:Ibs(Fs Lateral 133/160)!, -4.Allowable loads in the.F1 direction"aro not hdended to re dace 7.[islet to T-HTIEBEA0ING lorjselected hurricane lies allowable bearing enhaeeemenl loads; diaphI $.NAILS:16dx2'/z_0.162"dla(x2'/z"long,l0d=0.148"dia:x 3"long,•10dx1'/z=0.140"dia:x 1r/i'long; { the fr ss'a boundary members or prevent cross grain bending of ad 0.131 dia.x 2'/2"'Ionrq,8dxM=0.131"dia.x 1'/s"Innp:See page 16-17 for other nail sizes . the lruss'er ratter members.Additional shear transfer elements r -and Inla`mallon. 45 j t 9 r Hi Installation =112.5 Installation H2.5A Installation H2 installation 12:5T Inslallatimt,(Nails Info both top p/atesJ (Nails Into both top plates) (Nat/s/irlo both top plates), y r4 i 4... J- � lO I atinn II ' F1 -. H3 Installation (H2:5 similar l Ft F+ - (Nails Info.upper top:plate) (see loetgele 3)page 144 I V 112.5T Installation u H6.Shtll s to.To P Installation 6 Stud slo ln H4 Inslallation : - P 1 gh H. ® Joist In lalatto (Nails Info upper top plate) alatido (Nalls Into bolllllolp plates) (Nails lnld!i olhllop plalps) 163 RS-rA i l I: " 1 . • i r i Use a mfnlmum of two Od[falls -0its side at truss (Iola!lour Od i In lido.: truss)' ' i F+ - -Twoed halls. -.Into plates. HO attaching .Ntlallaching Hill H9 altohi attaching c ng 1 'EfUld ad 'It 1 a ter to double sfdU to sill' 1-jo t to double �. nails Into Truss to lop fs able studs top plates (4�8d Into plate fop plates plates H7Z Instailalon 64d into stud) i 4 ed COMMONS TO Od COMMONS TO HEADER f ��FILL ALL TRUE - ��PLATES.FILL ONE OF TFlIANGLE HOLES �i F �, THREE HOLES TO H14 TO STIINGHTENED ! F1 F, F2. f2. DOTTOMFLANGE. BOTTOM FLANGE j Hi0-2.Installation I- .H1O Installation ® H14'Inslallahon H14 Installation (NilZsfn►ilurJ; to double top plates ® to double 2x:header'' Ill 0 and H10R optional positive angle nailing cennecls shear(locking _ to rafter.Use 8d common nails.Slot allows maximum field-bending up to a pitch of 6/12,'use of-the table uplift load;bend one time only. Considerations.for Hurricane Tie.Selectuon Hurricane Tie_Installations to what Is Ilia uplift load?, . Achieve Twice•the Load_(Top View) 2: What is the parallel-to-plate load? ; 3. What is the per pendicular-lo-plate load? WALL 4. What,is the species of wood used'for the rafter and the top plates? WALL . WALL TOP : .. (Select the load.table based on the lowest performing species of wood.) PLATE 'TOP I PLATE TOP 5: Will the hurricane tie be nailed Into,both lop plates or upper LATE Mop plate only? 6. What load or loads-will the hurricane tie be taking?' (, Allowable simultaneous loads In more than one direction on a single -connector must be evaluated.as follows. `Design Uplift/Allowable Uplift'+Design Lateral Parallel.to Plate/ y Allowable Lateral, le Plate+Design Lateral Perpendicular te. Install diagonally across For H2:5A only— Nailhiy into halh sides of i Plate/Allowable Lateral Perpendicular to Plate<1.0. from each other for Products can he an Ilse a single ply tic truss may �b minimum 2x truss same side of Ille wall cause the wood to spier roh 7. Select hurricane tie based on performance,application,Installed cost provided they-are and ease.ol installation. sown V� configured as h a' FL The VB provides lateral resistance force.at the V8 Knee Braves bottorn of be: when installed apP.oximalely45"or more to the Vertical plane,; 2'/x MIN.. ;I MATERIAL,12.gauge. FINISH:Galvanized' �LI o INSTALLATION;•Use specliled fasteners.See General Notes• rHIOTSHOWN W .16-N54A fasteners are included with the brace. - �f CODES:Seepage 12 for Code Listing Key Chart..' 01 -------...___...------ ---- --- -- SIX N54A. Modol li'. L Fastenets :Alio1N a Tansid paU + bode NAILS - i No. (Beard Ueplh). .(Total).: ..Fldo'(100j. `' do .12 ). .ref i. VB5. 10'--15' 5' 16-N54A. 990 1240 ONE N54A I ' VB7 15 22yz' 7' 16-N54A 990 1240 IN EACH TAB VB8 22+Jx— '2G/ 3 r+/ E' 8 1 d�N64A :EI U. `` ,, 11C1{;..'5 '39 88• s TWO N54A VB'I0 + 121 ACCOMMODATES IN SEAT 36' 10' 16-N54A 96 iivld0'. BEAM WIDTHS OF VB12 36°-.42' 12 15N54A - 990 1240 3WTO103/,'... - 164 1:Root loads have been Increased 25"/"with no lurther increase allowed: Typical VB Installation is RSTA#.6291 HAVEN.HOMES N(NY): GREENPORT 1 ROOF DIAPHRAGM 15/32",CDX OR OSB(24/0-EXP 1)-PLY.CLIPS @EDGES • 8d NAILS @ 6"E.N 12"F.N. OR . R 7/16"X2"X16Ga STAPLES @ 4"E.N.,8".F N. ALLOWABLE SHEAR 308PLF/231 PLF 2 FLOOR DIAPHRAGM . .. 1/2""PLY TO PLY, CDX-OR OSB(24/0-EXP 1) ,T&G EDGES TOP PLY: 7d @ 6' E N.,.12"F.N. BOTTOM PLY: 10d @ 6"E.N.,,12".F.N. OR F 7/16"X2"X16Ga STAPLES @ 4":E.N. 8"F.N. ALLOWABLE SHEAR=372PLF/280 PLF 15/32"CDX OR OSB(EXP.1),OVER FRAME W/1/2":GYP' INTERIOR._ :. . PLY NAILING :,8d NAILS @4"EX, 12"F.N.OR 7/16'XZ%16Ga.STAPLES @ 2"E N.; 8"F.N.:' GYP.NALING: 5d NAILS-@,4"E.N., 10"F.N. OR EQUIV l l 2X SILL/MEMBER RECEIVE EDGE NAILING 1 TYPE'It PERFORATED SHEARWALL ALLOWABLE SHEAR:=615 PLF W/REDUCTION SHEAR WALL--Sz `. 15/327.CDX OR OSB(EXP 1) OVER FRAMING W/1/2"GYP' INTERIOR PLY NAILING 8d NAILS @ 2"E.N., 12"F.N. (E.N. SHALL BE STAGGERED) OR i 7/16'X2"X1.6Ga STAPLES " ( D) S GYP.NALING: .5d.NAILS @ 4'�E.N.,.10"F:N. OR EQUIV.L BE STAGGERED) 2 3X OR(2).2X SILL/,MEMBER RECEIVE EDGE NAILING - TYPE II PERFORATED SHEARWALL ALLOWABLE SHEAR=951 PLF W/REDUCTION SHEAR WALL--S3 ! . CDX OR OSB (EXP.1) ;OVER.FRAMING PLY NAILING 10d NAILS @ 2"E.N.,.12".F.N.(E.N. SHALL BE STAGGERED)OR 7/16"X2"X16Ga STAPLES @ 1"E.N., 8"F.N. (E.N. SHALL BE STAGGERED) 3X OR (2)2X SILL/MEMBER RECEIVE EDGE NAILING . S . TYPE II PERFORATED'SHEARWALL' g ALLOWABLE SHEAR=2002 PLF W/REDUCTION. J. l i i i l RSTA#6291 HAVEN HOMES (NY) GREENPORT. E 4 ROOF.RAFTERTO 2"tl FLR'S CEILING JOIST f PROVIDE 1/2"DIAM CARRIAGE THRU BOLTS PER RAFTER TO CEILING JOIST 5 2"tl FLR'S CEILING JOIST TO DBL TOP PLATES PROVIDE 1 1/4"X 16"0.019"STRAP TOP OF EA. CEILING JOIST TO DBL TOP PLATE OVER PLYWOOD (4)8d NAILS TOP OF CEILING JOIST, (3)Ad NAILS @ EA. PLATE :> PROVIDE (3) 16d TOE NAILS @ EA. END OF CEILING JOIST TO DBL TOP PLATE 6' PERIMETER ROOF RIM CONNECTION PROVIDE76d NAILS @ 0'-8"0.c..@ ROOF DIAPHRAGM RIM CONNECTION 7- 2"..,FLR,WALL STUD.TO FLR RIM PROVIDE"SIMPSON"LSTA12 STRAP @ 60"O C.WALL STUD:TO FLR RIM THE,SAME STUD SHALL HAVE A 1.1/4"x16"X0.019'--'STRAP ON.THE:OTHER END TO DBL TOP PLATE A . i . 8 PERIMETER 2"°FLR RIM CONNECTION PROVIDE 1/2"DIAM.THRU BOLTS @ 8' O.C.ALONG.PERIMETER 2 FLR RIM, ON SITE 9:. VERTICAL STRAP FROM 2"°FLR RIM TO 1g`FLR RIM PROVIDE SIMPSON."MSTC52"STRAP @ EA. GABLE END POST CENTERED @ RIM BAND, POST TO POST, ON SITE 10 RIM BAND CONNECTING 2"d FLR RIM TO 1'' FLR'S CEILING RIM JOIST PROVIDE 16d NAILS @ 4".O.C.,T&B,.ON SITE ! ' 11 ., RIM BAND CONNECTING 15`FLR RIM TO FOUNDATION SILL., PROVIDE 16d NAILS @ 3"O.C. ,T&VON ON SITE 12' PERIMETER 1s`FLR RIM CONNECTION PROVIDE 1/2"DIAM.THRU BOLTS @ 8'O.C.ALONG PERIMETER FLR RIM,.ON SITE. 13 1: FLR RIM TO CMU FOUNDATION HOLD DOWN.; PROVIDE SIMPSON"STHD14RJ"HOLD DOWN @ EA..GABLE END POST '. 14 HORIZONTAL STRAP CONNECTING MODULARS @ GABLE END FACE m. PROVIDE"SIMPSON"ST6224 STRAP.@ GABLE END FACE @ ROOF TOP PLATE PROVIDE"8IMPSON"8T6224 STRAP @ GABLE END RIM BAND @ EACH FLR DIAP. i 15, :,FOUNDATIONANCHORAGE i r-7 BOLT LINE 1 LINE 2 LINE 3 LINE A LINE B LINE C LINE D 'I x�r18���;� ;'12�O'Cx 18' 16"O C 8"02"O.0 24 O C 48�x0,C 48 O.0 32 O.0 f ��$ v " ;2C �-3; 48Oux 18' 32"O.C. 8"O.C. 4WO:C. 48"O.C. 48"O.C: 48'OC 48 O.C. i 55 R&S TAVARES ASSOCIATES TEL (209)863 8928 3324 SANTA.FE'STREET FAX. (209)"863 8952 . RIVERBANK,CA 95367 jAR APPENDIX.A 6' OPENING°HEADER DESIGN • NDEX OADINGSUMMARY 1 . 2.-3 ` PENING HEADER.DESIGN .4-6 i i . � I i i , i : TOTAL O F 6 ;PAGES. - RSTA#6291 APPENDIX fA Sheet_: 1 0 HAVEN HOMES f i ti (Stern Residence; . ; i Greenport, NY) i R&S TAVARES ASSOCIATES TEL.'(209)863 8928 3324 SANTA FE STREET FAX: (209)863 8952 RIVERBANK,CA 95367 M� W OPENING HEADER DESIGN' The header is over the 6'slider @breakfast room LOADING SUMMARY sf Roof&Ceiling•Assembly Dead Load ft I P 45 psf%g Ground Snow Load Ce.= 1.0 Snow Exposure Factor, per Table'7-2, P90,ASCE 7 02 Ct 1 F . Thermal Factor, per Table 7-3,.P91,ASCE? 02 Importance Factor, per Table 7-4,.P91,ASCE 7-02 Pf =-ma-(0.7•Ce•Ct-I-Pg)20•I) Flat Roof Snow Load, per Eq. 7-21 P78,ASCE 7-02 _ Pf—34.65 psf Flat Roof Snow Load Cs — 0 58 Roof Slope Factor, per Figure 7-2b, P84,ASCE 7-02 P C P Sloe Roof Snow Load s s f P , per Eq. 771, P77,ASCE 7-02 I Ps=20 1 psf Roof Snow Load - I wSNW-= PS'. Roof Snow Load wSNW—20.1 psf — psf Floor Dead Load �FLL 4 Psf Floor Live Load f i N'WDL 1 psf _.Wall Dead Load. ... I 13.75 . : WDLI 'RDL' 2 + WDL 8 WDL1 = 199: Of 13.75 WSNW1 = w'SNW':_ 2 WSNW1 = 138... plf : 13.75 WDL2. �'FD.L 2 WDL2 = 83 plf 13.75 WLL2: wFLL' 2 WLL2=275 plf RSTA#6291 f APPENDIX A Sheet 2 of HAVEN HOMES (Stern Residence, Greenport, NY) a R&S TAVARES ASSOCIATES ' TEL. (209)863 8928 3324 SANTA FE STREET _: RIVERBANK, CA 95367 FAX (209)'863 8952 34 WDL3 �RDL 2 - ' i WDL3 255 IL. 34 WSNW3•= WSNW' 2 WSNW3 -342 Of WDL4 WWDL 3:5 WDL4 =42 plf I �10 ,� PDL1 ��'FDL 1 + 'RDL'1� 2 : PDL1 .= 135 lb s 10 . ::PLL1 N'FLL 1. 2 PLL.1 -200 lb 10 II PSNW1 7SNW71' 2 PSNWI = 106 Ibs Ib Overturning force @ 2nd floor shearwall @ line 2, see sht. 18 of main calbs ., TB 87 Ib Overturning force @ 2nd.floor shearwalF.@ line B,see sht. 19 of main.calcs �) �I Ther. @ 25' uplift Ydownward.fo ce. 2. i from the left end of the header,, I� I T.= max Tg,T2) T_ 1827 due to.overturn ing of. hearwall- Ib 2nd floor @ line B or Li ne.e 2 whichever:is greater i { j SEE HEADER DESIGN ON SHT.4=6 ( USING "ENERCALC" SOFTWARE TO DESIGN) USE(3) 1.5"X9.25" 1.9E MICROLAM LVL OR EQUAL/BETTER HEADER OVER THE 6'SLIDER DOOR(a)THE BREAKFAST ROOM RSTA#6291 APPENDIX A HAVEN HOMES Sheet 3 of (Stern Residence, . Greenport, NY) is I ' Title: Haven Homes Stern Residence Job#RSTA#6291. Dsgnr: TM Date: 4:17PM,-11 OCT 06 Description :Opening Header Design i The Header is Over 6'Slider @ Breakfast Room I I :. . ;. Scope• I Rev: 580004 .. '. ....r .. I `. User.ICW-0606682,Ver5.8:0,1-Dec_2003 General .Timber Beam Page 1 (c)1983-2003 ENERCALC Engineering software RSTAti6291.ecw Calculations Description. .:6"OPENING HEADER v General Information Code Ref: 1997/2001 NDS,2000/2003 IBC,2003 NFPA 5000.Base allowables are user defined w: Section Name- (3)MicroLam:1.5x9. Center Span 6.00 ft Lu 0:00 ft Beam Width - 4.500 in Left Cantilever ft Lu 0.00.ft Beam Depth 9.250 in Right Cantilever ft Lu 0.00 ft Member Type Manuf/So.Pine . Truss Joist-MacMillan,Microl-am 1.9E I Fb Base Allow 2;600.0 psi Load Dur.Factor, 1.000 Fv Allow" 285.0 psi i. Beam End Fixity, Pin-Pin Fc Allow 750.0 psi, i i E 1,900.0 ksl i Full Len th Uniform Loads . � Center DL 42.00#/ft LL .# Left.Cantilever :DL #/ft` LL I .Right Cantilever: DL #/ft LL l ft .. #/ft Trapezoidal Loads - t #1 DL @Left 199.00 #/ft LL @ Left .138.00 #/ft Start Loc 0.000 ft DL @ Right. 199.00 #/ft LL @Right 138.00 #/ft End Loc. 2.250 .ft #2 DL @ Left 83.00.#/ft LL @ Left. 275.00 #/ft Start Loc 0.000 ft DL @Right 83.00 #/ft LL @ Right 275.00:#/ft. End Loc. 2.250 ft- #3 DL @ Left 255.00 #/ft LL @ Left 342.00 #/ft Start Loc 2.250 ft DL @'Right' .255.00 #/ft LL @ Right 342.00 #/ft End'Loc 6.000 ft Point Loads Dead Load 135.0Ibs Ibs 1.,781 0lbs Ibs Ibs w Ibs Ibs Live Load 200.0 Ibs 100.0 Ibs ` lbs . Ibs' Ibs . Ibs Ibs distance. 2.250 ft. 2.250 ft 2.250 ft 0.000 ft 0:000 ft 0.000 ft O.000 ft Summary - L M Beam Design OK Span=6.00ft,Beam Width=4.500in x Depth=9.25in,Ends are Pin-Pin Max Stress Ratio' 0.429 1 Maximum,Moment . 6:0 k-ft Maximum Shear " 1.5 4.4 k Allowable' 13.9.k-ft Allowable _ 11.9 k Max.Positive Moment 5.96 k-ft at 2.256 ft Shear: @ Left 3.48 k Max. Negative Moment 0.00 k-ft at, 0.000 ft Max Left Su •@ Right 2 79 k @ pport 0.00. k-ft . Max @.Right Support 0.00 k-ft @ Left 0.000 in. Camber @ Center 0.060 in Max.Mallow 13.90 :@ Right 0.000in I i fb 1,115.39 psi . .. fv. 105.05 psi. Reactions..., ..: 2.14 k Max yll Fb. 2,600.00 psi Fv 285.00 psi Right DL 1.62 k.. . Max 3.79 k Deflections I 2.79 k I! Center Span. Dead Load Total Load Left Cantilever,.. r Dead Load Total Load Deflection -0.040 in -0.063 in ' _ Deflection 0 n :.Location 2.856 ft, 2.904 ft 0.000 in 000 i ...Length/Deft` _ 1,798.5 1,149.83 .. . . Length/Deft 0 0 Camber(using 1.5'D.L.Defl).. 00 Right Cantilever... II; @ Center Deflection 0.000 in .0.000 in ' 0.060 in _ - i ...Length/Deft 0.0 0.0 @ Left 0.000 in @ Right 0.000 in I it i I • - is Title: Haven Homes,Stern Residence Job#RSTA#6291 Dsgnr: TM Date: 4:1.7PM, .11 OCT 06 Description :Opening.Header Design I The Header is Over 6'Slider @ Breakfast Room : . Scope Ver User.3-2 0606682,CALC n 1 Engineering o General Timber Beam g 2 (c)1963-2003 ENERCALC Engineering Software Page. RSTA#6291.e cw.Calculations Description 6'. OPENING HEADER Stress Calcs - Bending Analysis . 4 Gk 21.924 Le 0:000 ft Sxx 64.172 in3 Area 41.625 in2 Cf 1.000 'Rb 0.000 CI '; 0.000 Max Moment Sxx Read Allowable fb @ Center 5.96 k-ft 27.53 in3 2,600:00 psi @ Left-Support 0.00 k-ft 0.00 in3 2,600.00 psi .@ Right Support ,-0.00 k-ft 0.00.in3 2;600.00 psi 6: Shear Analysis @ Left Support @Right Support l Design Shear 4.37 k 3.45 k ` Area Required , 15.343 in2. Fv:Allowable 12.098 in2 285 00 psi. 285.00 psi Bearing @ Supports Max.left Reaction 3.48 k- Bearing Length Req d 1.03T in iIII Max.Right Reaction 2.79 k Bearing Length Req'd 0826 in Query Values I Shear Deflection . @ Center Span Location= 0:00 ft .I 0.00 k-ft 3.48 k 0.0000 in @ Right Cant.Location= 0.00 ft.. 0.00 k-ft 0.00 k. 0.0000 in �@ Left Cant. Location= 0.00 ft 0.00 k-ft 0.00 k' , 0.0000 in Il II i i i I �I i • I I ,I • I I I� I, III!! 42.00#lft r rr r t r r r i r , r rr 4 . T l 337.00#!ft f •i r f 337.00#/ft I358.00#/ft 7. 597.00#/ft 597.00#/ft II i� rr ► ��irr.►� r ► �i.r.1r ► r I� I� I 6.00 ft Mmax=5.96 k-ff j bmax==0.0626 in j Rmax=3.481 k Rmax=2.789 k j l Vmax @ left=3.481 k . Vmax @ rt=2:789 k L0ADznl4 DI GR I Ks TA 6 z q Sheet d of 6 j T TEST HOLE DATA SEPTIC TANK (I) DETAILS OF CONSTRUCTION z (TE5T HOLE DUG BY MGDONALD GEOSGIENCE I. CONCRETE SHALL HAVE A MINIMUM COMPRE551VE I. USE ONE (1) 1000 GALLON REINFORCED PRECAST p ON OCTOBER 3, 2005) STRENGTH OF 3,000 p5I AT 2& DAYS. CONCRETE SEPTIC, TANK. 'n EL. g.1' 0' MAX. SLOPE 59S 2. WALL THICKNESS SHALL BE A MINIMUM OF 4", A TOP 2. USE THREE (3) & FT. DIAMETER, 4 FT. HIGH PRECAST DARK BROWN CLAYEY LOAM OL FROM EDGE OF THICKNESS OF 8" AND A BOTTOM THICKNESS OF 6". ALL CONCRETE LEACHING RINGS. 15' MIN. HOUSE, FF = 16.7 FIN 15H GRADE 20' MIN. SANITARY OUT 20' WALLS, BOTTOM AND TOP SHALL CONTAIN REINFORCING DWELLING EL. 15.0' TO RE515T AN APPLIED FORGE OF 500 p5f. 3. USE 4 INCH DIAMETER, APPROVED SEWER PIPE BROWN CLAY GL `'I► ,r.+K THROUGHOUT. (q-(55) z TOP E:L. 14D -- I' MI MIN. 4" DIA. TOP EL. 14D "—1 MIN. 3. ALL JOINTS SHALL BE SEALED 50 THAT THE TANK 15 APPROVED PIPE WATERTIGHT. 4. THE WA5TELINE FROM THE 5EPTIG TANK SHOULD — EL. 53 3.4' 5EPTIG LEAGHING ENTER THE MAIN RING AS HIGH AS POSSIBLE. APPROVED PIPE TANK MIN. PITCH I/8" /I' POOL O 4. THE SEPTIC TANK SHALL BE INSTALLED AT LEVEL IN ST MIN. PITCH I/4" /I' : INV. EL. INV. EL. 12b ALL DIRECTIONS (WITH A MAX. TOLERANCE OF ±1/4 ) ON 5. USE ONE GRO55 OVER PIPE BETWEEN THE MAIN RING WATER IN o INV. EL.135 �- BROWN CLAY GL •�'""� INV. EL. 13.0 A MINIMUM 3" THICK BED OF COMPACTED SAND OR PEA AND THE TWO OUTSIDE RINGS, 8 INCHES ABOVE THE O y �► 13.q 8'-O" 3' GLEAN Z GRAVEL. BOTTOM. SAND COLLAR I() Z LP 6 4� SUBJECT 5. A 10' MIN. DISTANCE BETWEEN SEPTIC, TANK AND 6. BACKFILL MATERIAL SHALL BE GOAR5E SAND AND Y 130T. EL. g.5 HOUSE SHALL BE MAINTAINED. GRAVEL. 10' LP LP `j GROUND WATER p MIN. EL. 51' LEACHING POOLS (5I -1. SLABS SHALL BE BETWEEN 10" AND 14" BELOW Iy 0 OF 3 POOLS) GRADE. WATER IN BROWN FINE ' I. LEACHING POOLS ARE TO BE CONSTRUCTED OF 4� TO COARSE SAND SW :n PRECAST REINFORCED GONGRETE (OR EQUAL) LEAGHING 8. SOLID CONCRETE COVER SHALL BE BETWEEN 6" AND EP EP (6-65) T STRUCTURES, SOLID DOMES AND/OR S 12LABS. BE LOW GRADE. 2. ALL GONERS SHALL BE OF PRECAST REINFORCED q. BOTTOM OF POOL SHALL BE A MINIMUM OF 3 FIEET � � CONC ( )RETE OR EQUAL . ABOVE HIGH SEASONAL GROUNDWATER. 12, 11 KEY MAP GALE: I"=60 ' 3. A 10' MIN. P15TANOE BETWEEN LEACHING POOLS AND DRAINAGE STRUCTURE MIN. WATER LINE SHALL BE MAINTAINED. z SITE PUW OF: WATER MAIN ° PROPOSED STERN RESIDENCE TYPICAL.. PLOT LAYOUT SITUATED AT N.T.S. ARSHAMOMAQUE TOWN SU FO KF COUNTY,LNEW YORK S.C.T.M.# 1000-53-04-44.1 p/ BASED ON ORIGINAL SURVEY BY: JOSEPH A. INGEGNO LAND SURVEYOR DWELLING I DWELLING I DWELLING I DWELLING I DWELLING P.O. BOX 1931 (USES PUBLIC WATER) I (USES PUBLIC WATER) I (U5E5 PUBLIC, WATER) I (U5E5 PUBLIC. WATER) I (U5E5 PUBLIG WATER) RIVERHEAD, NY 11901 TEL: (631) 727-2090 m FAX: (631) 727-1727 W m DATED: OCTOBER 20, 2005 O - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - OWNER: .. r �Xf`�TING�i� R ..I ,I ., N POSILLICO CONSTRUCTION CO. INC. V >` THERE ARE NO WELLS WITHIN PROPOSED 5EWA0E D15P05AL 5Y5TEM: 265 POST AVENUE, SUITE 355 W Q� m 150 FEET OF PROPERTY USE 1000 GAL. SEPTIC TANK AND (3) 6' DIA. X 4' DEEP 3 K E R H I N BOULEVARD WESTBURY, NY 11590 LEAGHING POOLS. (TYPICAL ALL L ) (50' R.O.W) SITE DATA: " : f GROSS AREA: 336,490.11 SQ.FT.= 7.725 AC. 5345gOT E - - - - - - - - - -� - - - - - - T— - - - - - - - - - - - - - - POSTAL DISTRICT: 11971 SOUTHOLD ~ Xz � �.-`MIN. w I SCHOOL DISTRICT: SOUTHOLD y_ O • p lEP, CEP, FIRE DISTRICT: SOUTHOLD I , I PN c, I ELECTRICAL SERVICE: LIPA WATER SERVICE: SCWA I � `� I - - - `0'f=RONT-YQ`RD �T3LAGK_ - - - `LPE �'1 - - - - - I FLOOD ZONE: X 12 I a o ZONING: R-80 W N I u 5r � �' I 10 °s p SETBACK DIMENSIONS: - \ '� 8 PROPOSED: m PROPOSED TEST 14 4s 40' FRONT YARD PROP05EI�., 4g �T - w 51N6LE FAMILY.. GOVERED'.('ORG Iw I HOLE , Fil J to I 12 0 r�� � t /\16 50 REAR YARD tK cj F F.-�6., / I c� 4S I TOWN OF SOUTHOLD 15' SIDE YARD h 6 I / 4s : RECHAR ' Ic' }- USE GE 35 BOTH SIDES 8 BASIN 20% MAXIMUM LOT COVERAGE ENGINEER: < E=1 I SITE IS IN GROUNDWATER MANAGEMENT ZONE IVEy i 14 EAR DECK 6 s NOTE: PROPOSED DWELLING TO BE CONNECTED ; I 0 TO 300 CU.FT. DRYWELLS TO CONTAIN ROOF �,. U w --� 4 RUNOFF ON SITE v ' ?'acJ " I� '� 10 THEEE ARE AREA: �o n ��� � _ S' .� O ILLS ' TOTAL LOT AREA = 336,4g0.1I 5G.FT. FSS! t y ` <; �S WI,I 150 1O 12 . 14 16 WETLAND AREA = 31,1-18.2 50.FT. `�© Q� FE T F I - _ _ _ - _ - _ _ _ - - _ _ _ _ _ _ _ _ _ as JEFFREY T. BUTLER, P.E. 6' PR: P RTY REAR YARD SETBACK i TOTAL BUILDABLE AREA = 2gq,311.g1 50.FT. NOTE. \a° 4 TOTAL DEVELOPABLE AREA = IIq,415 50.FT. 50 FE AREET O INO HEL 5 (THIN 4 ,.�P� - 3g.g�5 OF BUILDABLE AREA L I I L — — — — —�— LINE OF DEVELOPABLE AREA — _ �0 — — _ _ _ . _ . — _ °ek ry�y y Se, REF. NO. RI0-06-0084 J�� v } _ _ _ . _ _ . _ . . _ . _ . _ _ ���ti O O Q CD 12 Py o PJ v �y���`L� P� S �,�m ems_ Q I� i Z } F ����� SUFiFOL3',COUNTY D!!_74A,7Z7_ , n% -�:"!. FC" t�ZdE^IsS ` O Z O i EXISTING LINE O WOODS °� y �pui z Np �j �� \yi 11� PFR;� F 4 A'`�''t✓i'�tcv�� .�.Ca." ,i° l i +s d f�).`70- v' > O < 0- I I ERE ARE NO WELLS WITHINjt `L` } O 12 y, ....._.. ,. 150 FEET OF PROPERTY d; 'E�-Y` m —1 WETLAND AREA 3-1,118.2 50.FT. ODED A b5 ACRES DJw O Ld ToTr.L C'v�wA,xl�.�:�1.�l�� IZ�?���:, i p✓ Q OPEN AREA (NON-WETLAND) .�.�' ll1 8 AREA = 17g,836.g1 50.FT. �- '� EXPIl ST1i EE Y G ri�a:3 P :r3 Lei '.T ®r i.7'"i ulPJ is,�l. CL OI = 4.13 ACRES ��ro I � F'�R1�AEel'TAF;`f,��'S'Y'Ei��'4>Ea�2k`:.CJ O �I L z I —►- 4Sv 4s BY HEALTH DL'I�ARTn"�tdT z z O 4 O 061 4L �S L V U 2 42'00" — '� — — — N 04 F214.26' W �W Zm G s� PACE : �s � Z.Z 0 SITE PLAN 3 z 01 EDGE OF WETLAND AS DELINEATED BY w Z EN—CONSULTANT, INC. ON DECEMBER H. 2005 40 20 c0 40 80 120y 160 200 CRAPHIG SGALE 1" = 40'-0" W Fs of I SURVEY OFG LOT 37 MAP OF AUGUST ACRES SECTION ONE I FILE No. 9107 FILED JUNE 3, 1991 SI T UA TED A T ARSHAMOMAQUE TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C. TAX No. 1000-53-04-44. 1 SCALE 1 "=50' OCTOBER 20, 2005 DECEMBER 16, 2005 ADDED ADDITIONAL WETLANDS AREAS MARCH 7, 2007 CORRECTED WETLAND BOUNDARY LINE APRIL 4, 2CO7 FOUNDATION LOCATION AREA = 336,490.11 sq. ft. 7.725 cc. I I I i CERTIFIED TO: TONY POSILLICO QO\f I s p PGA• epp ALI �\\) AG pia\ O�y I \ \ WOODED \ \ a_00 00 00 r Y FU J10 �0 �, y q, �9 Cr �°. 2 t—"o �� \ e \ r\v A 2 WOODED ------------ \ o \y� 016 f A c pro. Ira a°op5 o`c� CF b qq,, EDGE 11 QO�" \ CI EAR AREA \ Z O0- \ LIFO `,qP EDGE OF WOODS P yob diG C�`�,Gp FUG O lac, \�G FUG � f�� WOODED lll.L J MG M G Ofy°�F �,G �� yyj�•q\, FLAG / � J aLp OF(i FAG E mom\ I i Or- FLAG p-Ar, Ali �� i 'L FLAG FLAG ---FLAG Pt EEC FLAG MG 1LL ----FUG .,I" F•,PG FJAG ,1IIt FUG ID JxF f F1AG u FUG FJG v I n � I G � 'JO M !0 �fp II Ilk AIL. J f�F �G A LfF� I I I I i i i I I PREPARED IN ACCORDANCE!WITH THE MINIMUM STANDARDS FOR TITLE SURVEYS AS ESTABLISHED BY THE L.I.A.L.S. AND APPROVED AND ADOPTED FOR SUCH USE BY THE NEW YORK STATE LAND TITLE ASSOCIATION. a i' N N.Y.S. Lic. No. 49668 i� UNAUTHORIZED ALTERATION OR ADDITION TO THIS SURVEY IS A VIOLATION OF 0 FS� o v jr3h \ . I n r1 LA SECTION 72LA OF THE NEW YORK STATE ED.uCATION w. 1. ANY WETLAND BOUNDARIES SHOWN ARE SUBJECT TO VERIFICATION COPIES OF THIS SURVEY MAP NOT BEARING BY NEW YORK STATE AND/,OR OTHER REGULATORY AGENCIES. THE FL L' ui v r EMBOSSED SEAL SHALL SURR'SINOTOBE. CONSIDERED SEAL TO BE A VALID TRUE COPY. CERTIFICATIONS INDICATED HEREON SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED, AND ON HIS BEHALF TO THE Title Surveys — Subdivisions — S4e Plans — Construction Layout TITLE COMPANY, GOVERNMENTAL AGENCY AND LENDING INSTITUTION LISTED HEREON, AND TO THE ASSIGNEES OF THE LENDING INSTI— PHONE (631)727-2090 Fox (631)727-1727 TUTION. CERTIFICATIONS ARE NOT TRANSFERABLE OFFICES LOCATED AT MAILING ADDRESS THE EXISTENCE OF RIGHT OF WAYS 322 ROANOKE AVENUE P.O. Box 1931 AND/OR EASEMENTS OF RECORD, IF RIVERHEAD, New York 11901 Riverhead, New York 1 1 90 1-09 65 ANY, NOT SHOWN ARE NOT GUARANTEED. 25-084C r STA D. TE OF NE V1/.YORK EPARTME.NT OF.STATE, 41 STATE STREET... - ' ALBANY, NY 12231-0001 —- GEORGE'.E. PATAKF _ GHRISTOPHER L..JACOBS :• GOVERNOR- - ,' ,SECRETARY OFSTATE August 14,.,2006 Haven Homes, Inc PO Box 178 Beech Creek,` PA 16822. Attn: Michael English Re. Manufacturer No. M0349 -Application No. 06-055 . Dear Mr. Engllsh- Issued herewith:in response to your:application for approval of a modular structure is.New York State Factory Manufactured Approval designated as M0319-06-055, as authorized under Part 1209 of the Uniform Fire Prevention•and Building Code of.New York State. This approval.is limited to the factory manufactured portions of this building only.The approval for this structure is limited to project sites meeting the following criteria: I. Seismic design category A, B or 2 The-Ba-sic-wind-s-peed-shall-not--exc.eed-1-20-mph-and-exposure -..afiegory"C 3. The"ground snow load shall not exceed 45 psf. All fees have.been paid. The approval is confirmed by the stamp of approval placed on the enclosed set of documents and this qualifying letter. This'approval will remain in effect.for a period.of two years, unless sooner revoked, and is subject to renew.thereafter._Please provide a copy.of this approval to the Quality Assurance Agency: Sincerely, Ronald E. Piester Director ,.. ;. Division of Code Enforcement and Administration _ WWW.DOS.STATE.NY.US E-MAIL:INFO@DOS.STATE.NY..US "tom Permit Number MECcheck Compliance Report Checked By/Date New York State EnergyConservation Construction Code: .MECcheck Software Version33 Release lc.: `. Data filename: C:\Program Files\Check\MECcheck\POSILLICO-STERN.cck TITLE:PO01-STERN or COUNTY: Suffolk STATE:New York HDD: 5750 CONSTRUCTION TYPE:Detached 1 or 2 Family _HEATING"TYPE:Non Electric DATE:10/24/06 DATE OF PLANS: 10-23-06 .PROJECT INFORMATION: POSILLICO-STERN. . COMPANY INFORMATION: POSILLICO CONSTRUCTION NOTES: HAVEN HOMES,INC 554„EAGLE VALLEY•ROADJO BOX 178 BEECH CREEK,.PA 16822 COMPLIANCE:Passes Maximum UA=637 :Your Home=516 19.0%Better Than Code. . Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor,UA Ceiling 1:Flat Ceiling or Scissor Truss:: 1436 : 19.0 19.0 37 Ceiling 2`Cathedral Ceiling(no attic) 360 30.0 ` 0.0 12. Ceiling 3:: Cathedral Ceiling(no attic) 1. 93 19.0 0.0 : 5 Wall 1:Wood Frame; 16".ox.:. 3745 19.0 0.0 194 Window 1 Wood Frame,Double Pane with Low-E. 470 0.350 165 Door,1: Solid 39 . 0.173 7 Floor 1:All-Wood Joist/Truss,.Over Unconditioned Space 2044 19.0 0.0 96 COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with•the building . plans,specifications,_and other calculations submitted with this permit application. The proposed systems have been designed to meet the New;York State Energy ConservationConstruction Code requirements. When a Registered Design Professional has stamped.and signed this page,they are attesting that to the best`of his/her knowledge,belief; and professional judgment,such plans or,specifications are in compliance with this Coder Builder/Designer 11 Date ., MECcheck Inspection Checklist New York State EnergyConservation Construction Code • MECcheck Software Version 3.3 Release lc DATE:-10/24/06. TITLE:POO1-STERN -,Bld . g Dept. 'I Use I Ceilings. Ceiling 1;Flat Ceiling or Scissor Truss,R 19.0 cavity+R-19.0 continuous insulation Comments: 2. Ceiling 2: Cathedral Ceiling(no attic),R-30.0 cavity insulation, - I, Comments: [ - ] I 3 Ceiling 3: Cathedral Ceiling(no attic),R-19.0 cavity insulation Comments: j:'Above-Grade Walls:. [ ] 1. Wall 1:.Wood Frame, 16"o.c.,R-19.0 cavity insulation Comments: . I Windows . .. 1.[ Window 1: Wood Frame,Double Pane with Lo w-E,U=factor: 0.350 For windows without labeled U-factors,describe features: #Panes ` Frame,Type Thermal Break? [ ]Yes [ ]No. i Comments: Doors' [ ] I 1. Door 1: Solid,U-factor:6.173. I: Comments: 1 Floors: [ ] I. Floor I:All-Wood Joist/Truss,Over Unconditioned Space,R-19.0 cavity insulation Comments: Air Leakage: .: [ ] - Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly 'with a 0.5"clearance from combustible materials.If non-IC rated,the fixture must be installed with a. 3"clearance from insulation. I , Vapor Retarder: Required on.the warm-in-winter'side of all non-vented framed ceilings,walls;and floors: I , Materials Identification. ] Materials and equipment must be installed in accordance with the manufacturer's installation.instructions.. . [ ], Materials and equipment must be identified so that compliance can be determined..' [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided.. [ ] I Insulation R-values and glazing U-factors must be clearly marked on the building plans or specifications. Duct Insulation. Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-4. , .] Supply ducts in unconditioned spaces must be insulated to R-8.. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R 2. . Insulation is,not required on return.ducts in.basements. Duct Construction: . I All joints;seams, and connections must be securely fastened with welds,gaskets,mastics.. (adhesives),mastic-plus-embedded-fabric,or tapes. Duct tape is not permitted. J Exception. Continuously welded and locking-type longitudinal joints.and seams on ducts operating at less than 2 in.w.g.-(500 Pa). Ducts shall be supported every 10 feet or in accordance.with the manufacturer's instructions. ' [ ] Cooling.ducts with exterior insulation must be covered-.with a vapor retarder.: j Air filters are required*in the return air system.: .= The HVAC system must provide a means for balancing air and water systems - Temperature Controls: ,Each dwelling unit has at.lesat one thermostat capable of automatically adjusting the space J 'temperature set point of the.largestzone: . Electric Systems: . [ ] Separate electric meters are required for each dwelling unit.., ; Fireplaces: . [ ] '-Fireplaces must be installed with tight fitting non-combustible.fireplace doors. . . [ ] Fireplaces*must be provided with a source of combustion air,as required by the Fireplace construction J-:,provisions of the Building Code.ofNew York State,the Residential Code of New York State or the New York City Building Code,as applicable. . Service Water Heating: Water heaters with vertical pipe risers must have aheat trap on both the inlet and outlet unless the Water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels.in Table 1. Circulating•Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. , f Swimming.Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 20% . of the heating energy is from non-depletable sources. .Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55°F'must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes ' ; Heated Water Non.-Circulating Runouts Circulating Mains and Runouts :Temperature(F) Up to 1" Up to 1.25" . 1.5"to 2.0" Over 2" 170-180 0.5 .. ,.. 1.0 1.5 2.0 : 140=160 O S '0.5 1 0 1.5.'.,, 100-130 0.5 0.5; '0.5: 1.0 Table 2:' Minimum Insulation 71ticknessfok HVAC Pipes. FluiPipmSystem Types Range Temp. 2 Insulation Run Runouts Thickness nd, a Inches b Pipe Sizes " d Less . 1.25"to 2" 2.5"to 4" Heating Systems. Low Pressure/Temperature . 201-250 1.0 1.5 1.5 2.0 Low Temperature .120-200 0.5 1.0 1.0 1.5 Steam Condensate(f6r feed water) Any., 1.0 1.0 1.5 ,. 2*0 Cooling"Systems -chilled Water,Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 4.0: 1.0 1.0' 1.5 15 NOTES TO FIELD(Building Department Use Only) 1 R .A S Tavares- Associates' Design Cons-ulting :: Project Management 33.24 Santa Fe Street, Riverbank; CA 95367 (209) 863-8928; fax: (209) 863-8952.. Web: www.r'stavares.com RSTA JOB#6291 October 17,2006 FOR: NAV M - JOB: ERN- E-tW -554 EAGLE VALLEY RD 154 KERWIN BLVD P.O.BOX 178. : GREENPORT, NY BEECH,CREEK,PA 16822 OF N RYIIDER: PO51LLIc0 CONSTRUCTION l-o . 1Z MPH WIND-3 SEC GUST, EXPOSURE'C' 0 PER ASCE 7-98/AF&PA/WFCM 95 ' o-4252TIT ;.. 31' U. TURAL 3ALC:U[ATONS 2006 INDEX Cover Page 1 Loading Summary 2-3 Wind Distribution per ASCE 7-98, 4-7 Allowable Diaphragm Schedule g Simpson Connector Design Values 9 Roof Diaphragm Design/Continuity Check 10-15 Shear Force Summary @ 2nd Floor 16 "Shear Wall Design @ 2nd.Floor . 17-20 2nd Floor Diaphragm Design 21 2nd.Floor Diaphragm'Continuity Check. 22-23 Shear.Force Summary @ 1st Floor 24 Shear Wall Design @ 1st Floor 25-32 1st Floor Diaphragm Design/ Continuity Check. 33-37 Lateral Framing Connection . .38-39 Foundation Shear Anchorage 40 ,Attached WFCM Supplement 41-46. Simpson Connectors . . 47-52 a Appendix A - 6',Opening Header Design 1-6 . Tptal of " 55+6 61 PAGES ALL FIDLD DPIVNS, SCRAPS; NAILS SPINES; Sxt1I'LLS, OR ,ANY. CQNNCCTOR CAN BE SZIB ST ITTI�'GD TVITI� EQLIAL.:;OR BETTER :fI�1RDkVA'RE: . R&S.TAVARES ASSOCIATES TEL::(209)863 8928. 3324 SANTA FE STREET i- RIVERBANK, CA 95367 A�VpppAR/jEyS 'FAX: (209)863 8952 GRAVITY LOADING SUMMARY ROOF Roof Pitch'@Bldg = 9/,12 8 ft Ceiling Ht. wL — 15 psf Roof&:Ceiling Assembly Dead Load N'SNW 45 psf ' Roof Snow Load ceil 5 psf Ceiling Dead.Load WDL sf Wall Dead Load. w 12 p . FDL — sf Floor.Dead.Load LATERAL LOADS TO ROOF FRAME:'- WINDS LOAD @ 120 mph, 3 sec Gust, Exp."C", 9/12 Roof.Pitch Per ASCE 7 98 I.=:1 Category II per Table 6-1 ASCE Pg. 55 V 120 Equi. Basic Wind Speed (3 Sec Gust) Kd 0.85. .: Wind Directionality Factor, per Table 6-6 ASCE Pg.61 Kz1 ;= 0.85 Velocity Pressure Exposure Coeeficients per Table 6-5 ASCE Pg.60 1Jp,to Roof Mean Ht of,15'.Elev. Kz2 0 90 Velocity Pressure Exposure Coeeficients per.Table 6-5 ASCE Pg.60 Up to 23' Elev. "Kzt;= 1 0 Topographic.Factor per'ASCE 6.5.7.2 &ASCE 6.4.1-7 qhl 0 00256 Kd•Kzl'Kzt-V21 Velocity�Pressure (lb/ft"2)per Eq.6-16'ASGE Pg.32 Up to 15' Elev. ,lb. qh l E276,76712 - .. ' g qh2:= 0 00256 Kd-Kz2•Kzt.V2 I Velocity Pressure (lb/ft^2)per. E,q.6 16 ASCE.P6.32. . Up to 23'Elev. . Ib. P gh•�GCpf GCpi) Design Wind Pressure per Eq.6 16 ASCE Pg:32 psf RSTA#.6291 STRUCTURAL CALCULATIONS 'Sheet 2 of HAVEN HOMES (Stern Residence, Greenport, NY) SEPTIC TANK (I) DETAILS OF CONSTRUCTION TEST HOLE DATA z (TEST HOLE DUG BY � sias�wrwww MGDONALD GE05GIENGE I. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE I. U5E ONE (1) 1000 GALLON REINFORCED PRECAST p ON OCTOBER 3, 2005) STRENGTH OF 5,000 psi AT 2& DAYS. CONCRETE SEPTIC TANK. EL. clY O' MAX. SLOPE 5% 2. WALL THIGKNE55 SHALL BE A MINIMUM OF 4", A TOP 2. USE THREE (3) & FT. DIAMETER, 4 FT. HIGH PRECAST DARK BROWN CLAYEY LOAM OIL FROM EDGE OF THICKNESS OF 6" AND A BOTTOM THIGKNE55 OF 6". ALL GONCRETE LEACHING RINGS. HOUSE, FF = 16,7 FINI H � 20' MIN. 15' MIN. I� S GRADE SANITARY OUT 20 WALLS, BOTTOM AND TOP SHALL CONTAIN REINFORCING DWELLING EL. 15.0 TO RE515T AN APPLIED FORGE OF 300 psf. 3. USE 4 INCH DIAMETER, APPROVED SEWER PIPE BROWN CLAY GL �► N,,,,rv++ THROUGHOUT. (g-65) TCIP EL. 14.0 r 1' MIN. TOP EL. 14D --I' MIN. 3. ALL JOINTS SHALL BE SEALED 50 THAT THE TANK IS �z � MIN. 4" DIA. 6" WATERTIGHT. 4. THE WASTELINE FROM THE SEPTIC TANK SHOULD -f EL. 5.7' APPROVED PIPE 3.4' SEPTIC LEACHING _ ENTER THE MAIN RING AS HIGH AS POSSIBLE. APPROVED PIPE TANK MIN. PITCH I/8" /I' POOL O 4. THE SEPTIC TANK SHALL BE INSTALLED AT LEVEL IN _ ST MIN. PITCH 1/4" /1' i WATER IN INV. EL. Q. EL. 12b ALL DIRECTIONS (WITH A MAX. TOLERANCE OF ±I/49 ON 5. USE ONE GROSS OVER PIPE BETWEEN THE MAIN RING BROWN CLAY GL INV. EL. IW. EL.135 13.0 `r 13.g A MINIMUM 3" THICK BED OF COMPACTED SAND OR PEA AND THE TWO OUTSIDE RINGS, & INCHES ABOVE THE O (q-65) &'-0" 3' GLEAN g�_O�� z GRAVEL. BOTTOM. + SAND COLLARY-j ff1 z LP 6' 4 SUBF�GT 5. A 10' MIN. DISTANCE BETWEEN SEPTIC TANK AND 6. BAGKFILL MATERIAL SHALL BE COARSE SAND AND 10' �j BOT. EL. cIS HOUSE SHALL BE MAINTAINED. GRAVEL. LP LP GROUND WATER MIN EL. 5.7' LEACHING POOLS (5) 7. 5LAB5 SHALL BE BETWEEN 10" AND 14" BELOIW (I OF 5 POOLS) GRADE. WATER IN BROWN FINE I. LEACHING POOLS ARE TO BE G0N5TRUGTED OF TO COARSE SAND SW $ o PRECAST REINFORCED CONCRETE (OR EQUAL) LEACHING 8. SOLID CONGRETE COVER SHALL BE BETWEEN 6" AND EP EP (6-65) N STRUCTURES, SOLID DOMES AND/OR SLABS. 12" BELOW GRADE. 2. ALL COVERS SHALL BE OF PRECAST REINFORCED q• BOTTOM OF POOL SHALL BE A MINIMUM OF 51 FEET �,io, KEY MAP CONCRETE (OR EQUAL). ABOVE HIGH SEASONAL GROUNDWATER. 12' SCALE: I"=60 ' 3. A 10' MIN. 015TANGE BETWEEN LEAGHING POOLS AND DRAINAGE STRUCTURE MIN. WATER LINE SHALL BE MAINTAINED. z SITE PUN OF. WATER MAIN ° - PROPOSED STERN RESIDENCE TYPICAL PLOT L SITUATED AT I N.T.S. ARSHAMOMAQUE TOWN OF SOUTHOLD SUFFOLK COUNTY, NEW YORK S.C.T.M.# 1000-53-04-44.1 tY BASED ON ORIGINAL SURVEY BY: JOSEPH A. INGEGNO _ LAND SURVEYOR DWELLING ( DWELLING I DWELLING I DWELLING I DWELLING P.O. BOX 1931 (USES PUi31_I6 WATER) I (USES PUBLIC WATER) I (USES PUBLIC, WATER) I (USES PUBLIC, WATER) I (USES PUBLIC WATER) I RIVERHEAD, NY 11901 TEL: (631) 727-2090 m FAX: (631) 727-1727 W O DATED: OCTOBER 20, 2005 a - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - OWNER: .. r Icy- YJ- W WH W H H H H H H H H H H- W YVW H W IMWW- WW' W' YJ--W W- W- TI-IERE ARE NO WELLS WITHIN EXI' TING R4TER MAff POSILLICO CONSTRUCTION CO. INC. 150 FEET OF PROPERTY PROPOSED SEWAGE DISPOSAL SYSTEM: USE 1000 GAL. SEPTIC, TANK AND (3) &' DIA. X 4' DEEP r K E R H I N E3 O U L E V A R D WE POST AVENUE, SUITE 355 STBURY, NY 11590 LEACHING POOLS. (TYPICAL ALL L ) (50' R.O.W.) SITE DATA: X s 34°5g'00" E } GROSS AREA: 336,490.11 SQ.FT.= 7.725 AC. X z �- - - - - T— - - - - - - - - - - _� - - _ - - - _ T— - - - - - - - - - - - - - - POSTAL DISTRICT: 11971 (SOUTHOLD) 10' ( SCHOOL DISTRICT: SOUTHOLD O p Epp EEP MI.N. w I II FIRE DISTRICT: SOUTHOLD Lu v ��' ELECTRICAL SERVICE: LIPA w co ci) ALP; L }. s WATER SERVICE: SCWA D_ _ Ikz a , FLOOD ZONE: X Q .• ALP, O � I 12 � � o o ZONING: R-80 W �y I sr;l w I 10 o SETBACK DIMENSIONS: 60' FRONT YARD ETBAGK _ `IJ _ _ �" _ _ \ _ _ = F-) - - - - - - - - I I 14 8 s PROPOSED: 11 PRopoSED PROP05 PORC HOLE , 4s 40' FRONT YARD Q I SI &LE F MIILY"... GOVERE 12 ,v � 16 � � 50' REAR YARDDHE � uj i (4 etvEzoor-U I ;y TOWN OF 5OUTH0LD 15 SIDE YARD ti �- E7 w Iw USE: RECHARGE 35� BOTH SIDES 18 s Its) 4 BA51N 20% MAXIMUM LOT COVERAGE Q1=3 / Q ENGINEER: \ / SITE IS IN GROUNDWATER MANAGEMENT ZONE IV �Ja PROP-95 I w �Q� F,S,v T. wl O I Q 14 EAR DECK 6 4s NOTE: PROPOSED DWELLING TO BE CONNECTED TO 300 CU.FT. DRYWELLS TO CONTAIN ROOF — -� cv 4s RUNOFF ON SITE n ,R,i L R �" THE ARE - - - 10—r- —% �-15' REAR YARD SETBACK ,, I TOTAL LOT AREA = 336,4g0.l l 50.FT. \ I < I (y0 LLS Es� .__.._. .WIT I 150 IO 12 . 14 FET F 16 4s 3 WETLAND AREA = 3-1,115.2 50.FT. (Y P •••••• � `` ' JEFFREY T. BUTLER, P.E. 1-3 PR RTY i +J� i TOTAL BUILDABLE AREA = 2gg,311.gl 562.FT. TOTAL DEVELOPABLE AREA = IIq,475 50.FT. Z NOT THERE ARE NO WELLS WITHIN 3g.gh5 OF BUILDABLE AREALL 11 0 150 FEET (OF PROPERTY -1 I - - _ -f LINE OF DEVELOPABLE AREA— - - ;`�°y / 4 �J'OPHS REF. NO. R - � Q �- L . . _ . . _ . . _ . . _ . . _ . . _ . . _ . . _ . . _ . . _ . . _ . . 10-06-OOS�i LLI z , O z } I Z I EXISTING LINE OF WOODS N0_1 } I (� I ERE ARE NO WELLS WITHIN O 12 J m I50 FEET OF PROPERTY ' I z Q IT) < -1 c=3 WETLAND AREA = 37,178.2 562.FT. 4s a UJz � I W ODED = .&5 AGRES _ 10 <. _ — � � 0 O >Y #' O t!1 w <;8 OAREA 7g,836.g l PEN AREA ESG2 FNTD) -- CL . T_ m 0 O <; = 4.13 ACRES O < —� Q _ 4s O O �I<' < _ � s O z z I<; _._�. — 4 W O<, O < 1=3S s s 4 may/ 1=12 42'00" "- a N f 214.26' PAGE : � /�' o� I AGE : V/ SITE PLAN v, V EDGE OF WETLAND AS DELINEATED BY - W z 4S EN-CONSULTANT, INC. ON DECEMBER 8, 2005 40 20 O 40 80 120 160 200 GRAPHIC SC ALE 1" = 40'-0" WIND SUBJECT TO DAMAGE FROM WINTER ICE SHIELD USE/ JEFFREY T. BUTLER, PE,, P',C, GROUND SPEED EXPOSURE :rEISMIC FROST DESIGN UNDERLAYMENT FLOOD LIVE DEAD, ROOF UPLIFT LOAD WALL SHEATHING OCCUPANCY HEIGHT FIRE AREA TYPE OF RESPONSIBILITY IS LIMITED t0 SNOW DESIGN LINE LOAD (MPH) CATAGOi�Y CAtAGORY WEATHERING DEPTH TERMITE DECAY TEMP REQUIRED HAZARDS LOAD LOAD SUCTION LOAD CLASSIFICATION CONSTRUCTION THE FOUNDATION, COVERED PORCH, MODERATE SLIGHT TO FROM 1'J98 PERIMITER EDGE ZONE ■ 3'1.2 per EDGE ZONE ■ 29.1 per FIRST FLOOR • SEE PLAN AND REAR DECK ONLY, SEE PLAN 45 6f 120 B G SEVERE 36" II YES 40 pef 20 pef INTERIOR ZONE • 29.6 6f INTERIOR ZONE ■ 24.6 of SFD NA SECOND FLOOR • BY OTHERS TYPE V BY OTHERS FOR FACTORI'' PRE- P to HEAVY MODERATE FIRM MAPS p p MANUFACTURED MODULAR UNITS, NOTE: DESIGN CRITERA IS FOR FOUNDATION COVEREID PORCH AND REAR DECK DESIGN ONLY. SEE DETAIL ON SHEET 2 FOR HIGH WIND CONNECTION REQUIREMENTS 1 71'-6'/z" 49'-0t/2' \ l c� z 6'4" 6-10" 6' 4" ' 20'-0" t 3" I u}j 24"x24" x MIN 12" DEEP LINE OF ut 6'-0" 1 8'-0" 6'-0" _ a TO UNDISTURBED 501E ' ' ' I DECK ABOVE 1 I 1 1-10 : I --�--.'__.-----_ _ --L-------------J-- -J------------J-- O'1Q 1 12" DIA. P.G. PIER TO GRADE -'- - -- -��- - -- -I-� -1- - - - -�_e IQ 29'-0'/i 1 , 1 2-&k; CCA I 2-2x10 CCA 1 1 2-2XIO CCA 1 z 1 ' 1 P.G. PEER WITH 6x6 GCA 1 I --- ' I `-�---' GIP'JER _--_-. GIRDER GIRDER •-- r•-1'U 7'-6V2" 7'-4" 7'-4" POST TO DECK GIRDER. Q 8'-9" 11'-3" ANCHOR PER DETAIL : 6'4" U 6'-10" 6' 4" 1 1 SHEET, TYP. 1 3" LINE OF , '3' _-- DECK ABOVE r-----, r-----, r___r-, r-----, PROVhDE ANCHOR BOLTS IL T I I I I I , I I I I I I I I I I I 2-2xIQ CCA ' 2-2x10 CCA ' ' 2-2xl0 CCA ' -J----4-PkIErG64--- L- -1---3-ikld 6e✓�4---_1- -1__- -2-2x10CC-Ar----1 -I---j2-2 IE�6 A----J-- ' EAC►IH CORNER SEE DETAIL 1 - +- - -- - - - --+-- - + - -*- - - -I--�- - - - �� -- - -- -I- �• -+ -- - ---+-- - -- - - -� -e ' ONISHEET2. PROVIDES/8" I I GIpER I GIRDER 1 1 GIRDER I I GIRDER I I GIRDER 1 1 GIRDER I 1 GIRDER I , : x `____-� `_ I I ANCHOR BOLTS 36" O.C. MAX. --i WITHN I' OF EACH SPLICE IN a SILL PLATE ' 2817 --- Lu 00 00 JU Lu LL L L JEFFREY T. BUTLER, PE., P.C. RESPONSIBILITY IS LIMITED TO THE FOUNDATION, COVERED PORCH, AND REAR DECK ONLY, SEE PLAN BY OTHERS FOR FACTORY PRE- MODULAR MANUFACTURER MANUFACTURED MODULAR UNITS. TO SPECIFY ALL CONNECTIONS ABOVE SILL/SOX CONNECTION o � o � o � 0 0 0 0 r ° °°°° 0 °° o 0 o p ijj o° o z LTP4 - 16" 0,C o AT EXTERIOR °° ° p 0 PERIMITER AND 00 GARAGE/HOUSE °° °° COMMON WALL I USE 4-8d NAILS AT EACH END SILL PLATE TO RIM I JOIST AND 11RIM JOIST' TO STUD CONNECTION z NTS aru ql STEP STAIR AND RAIL PER CODE Simpson Strong-Tie U210 2X6 AT EACH RAFTER O 4-10d x 1 1/2" n iJ— rL NOTE: 04 5/4" x 6" CEDAR DECKINn r- ATTACH LEDGER TO FRAMING MEMBER WITH 2-1/2" X 5" LAG BOLTS AT 16" m ON CENTER JU ,� m X Sim son Stron -Tte X � Q p 9 � z ,L U210 2X(O . AT EACH CEILING JOIST 3: O _ 4-10d x 1 1/2" O N O Simpson Strong-Tie csl a U210 2X6 �.o AT EACH DECK/PORCH JOIST 4-10d x 1 1/2" , � F= TYPICAL PORCH/DECK LEDGER CONNECTIONS ' ENGINEER: FACTORY PRE-M:4NUFACTURED HOME PLAN BY' OTHERS aPu' 7n Y I JEFFREY T. BUTLER, P.E. • � m GARAGE Wtu qq � PLAN BY OTHERS V O m = z cD U I � z � W z a • Simpson Strong-Tie 0 o Q AC4 U N AT EACH POST N id W o CC az Z } m > Z cc m p / CONT. 2x10 GCA LEDGER W z (L T1. v) f> � ^ u oc° �• II � a ° N o "P �" Qi ' m .4 a eo�9 di — Ul (L U U ,� — d .L, — /5/4" x 6" CEDAR DECKING 0 IF- o 5" DECROTIVE PORCH R'6 66 a j " \ v Q o 0 ' COLUMN. ALIGN WITH Q 8 R. II " p/ PIERS BELOW, TYP. p i� • 16" o Iro" O.C.O. '- 2-2x10 2-2x10 2_2x 10 II 2.! 11:11-2x10 2-2xIo 2-2x10 0.. � 0 GIRDER - - _ _ GIRDER - IR ER - - _ - - - - GIRDER - GIRDER - _ - - _GIRDER _ - U. -" V _9 O . . i O _. '� 0 2" MINIMUM •---------------------------------------------- ------- ---------6t---------- - ----------------------------------------------------- ®'• 2,/4" PLYWOOD GABLE z SIDECOVER • '•$°�. •• Simpson Strong-Tie STAIR AND RAIL PER CODE IN FLIP SHAPE U � a • PBS44 AT EACH POST FOOTING 7'-0" 7'-0" W-0" 7'-,6" 4'-0" 7'-0" 7'-2'/8" I ORCH COLUMN CONNECTIONS 43'41/a' NTS PORC>1� � DECK FLAN PAGE : 2 of 2 a g SEISMIC DESIGN CRITERIA LABEL LOCATION '' IN REFERENCE TO CLIMATIC AND GEOGRAPHIC (I)-TRA LABEL PER DWELLING PER UNIT SEE FLOOR SEISMIC DESIGN CRITERIA REFER TO CALCULATION PLAN FOR LOCATION WHERE REQUIRED BY STATE. MANUAL VOLUME V FOR STRUCTURAL MEMBERS (!)-DATA PLATE PER DWELLING SEE FLOOR PLAN TO BE USED FOR SPECIFIC LOCATION. FOR LOCATION WHERE REQUIRED BY STATE. (0-STATE LABEL PER DWELLING SEE FLOOR PLAN h* k. CATEGORY A, B, C. Di, 02 FOR LOCATION WHERE REQUIRED BY STATE N FOR FASTENING SCHEDULE SEE TRA APPROVED a CERT./ QUALITY CONTROL MANUAL PAGES TYPE OF CONSTRUCTION: RESIDENTIAL/ WOOD FRAME -IV-D.71 THRU 13 CONSTRUCTION IN ACCORDANCE TO SECTiON 10 OF BCNYS ® w AND RCNYS SECTION 101.2. 04 PROJECT SPEC I r I C INFORMATION FOUNDED ON EXGELLENGE AND BUILT KITH PRIDE � USE GROUP: R- r e!"� TYPE OF CONSTRUCTION: WOOD FRAME, UNPROTECTED N E W Y 0 R K 5 T A T �' C0 Y E 5 H E E T Lu RAFTERS: SNOW LOAD: 45 PSF MANUFACTURING PLANT ADDRESS: MANUFACTURING PLANT ADDRESS: U DEAD LOAD' 10 PSF CORPORATE OFFICE ADDRESS: oz 554 EAGLE VALLEY ROAD 554 EAGLE VALLEY ROAD 306 RUNVILLE ROAD 47 -- CEILING JOISTS: STORAGE P.O. BOX 08 BELLEFONTE, PA. 16823 Lu L LIVE LOAD: 20 PSF P.O. BOX 178 DEAD LOAD: 10 PSF BEECH CREEK, PA. 16822 BEECH CREEK, PA. 16822 z _ cfl FLOOR: NON SLEEPING AREAS ch oz a, 1 l 04 c LIVE LOAD: 40 PSF SLEEPING AREAS Lu x LIVE LOAD: 30 PSF WINDOW SCHEDULE (� QUANTITY MANUFACTURER DESCRIPTION ROUGH OPENING W x H EGRESS DP RATING UNIT LIGHT UNIT VENT UNI1 AREA O 0 W o w -1 DEAD LOAD: 10 PSF U-- 17 A�NDERSEN 3052 38 !/8' x 64 7/8" YES 50 12.03 6.67 17.18 � p � � / 2 ANDERSEN 20210 26 I/B' x 36 7/8" NO 50 3.68 2.18 6.69 � � � to WIND LOAD: 120 M.P.H. WINDZONE WITH ±/ 3 A�NDEP,SEN 2052 26 1/8' x 64 7/8" NO 50 7.37 4.31 11.77 3 SEC GUSTS 'EXPOSURE C' D R A W 0 N (S 0 ND EX AWDERSEN 2432 1 30 1/8' x 40 7/8" NO 50 1 5.09 2.94 8.55 LOAD' 45 PSF 1 AUIDERSEN 2442 30 1/8' x 52 7/8" NO 50 7.01 4.02 11.06 SNOW L AINDERSEN B52127 22' x 27 112" NO 40 1 3.20 0.00 1 4.20 G E S I s N B v I L D I N G CODES SHEET # DRAWING NAME DOOR SCHEDULE 2002 RESIDENTIAL CODE OF NEW ORK STATE A COVERSHEET AND NOTES QUANTITY GE:??0068TI0N ROUGH OPENING" W x H UNI0.00GHT UN20.63NT UNIT AREA 1 _ 1999 NATIONAL ELE�RICA DE W/ NEW YORK AMENDS 1 9468 SL 16' x 82 1/2- 2.00 8.33 8.17 A-1 FIRST FLOOR PLAN 1 -�3s6 32• x 82 1/2• o.o0 18.33 iB.33 ENERGY CONSERVATIO TRUCTION CODE OF NYS-2002 EDITI ) LIGHT AND VENIT A-2 SECON1 FLOOR PLAN ROOM NAME � IGH? REQUIRED LIGHT PROVIDED LITE REQUIRED LITE SOPPIER GENERAL 1 N O R p0 A V I O N DINING ROOM _', _.._18./2 32.40 9.36 15.56 KITCHEN 17.20 7.36 + ARTIFICIAL 8.60 4.36 + MECHANICAL UVIDERVIRITERSCERTIFICATE E- A-3 FOUNDATION PLAN BREAKFAST H 11.28 - 32.40 5.64 15.56 OF NE Lu ' TO THE BEST OF MY KNOWLEDGE, BEUE� AND PAOFFESIONAL FAMILY ROOM - 26.06 71.20 13.04 37.52 REQUIRED c�P�� N&A rA w`o } z JUDGEMENT" THESE PLANS ( AND SPECIFICATIONS) ARE IN LIVING RTO"F -i7.68- 48.12 8.84 26.88 C 9�a �� , �a z D4 63 COMPLIANCE WITH ENERGY CONSERVATION CONSTRUCTION CODE A-4 ELEVATIONS FOYER 3.52 4.00 + ARTIFICIAL 6.76 13.34 sir DEN 13.52 24.06 6.76 13.34 OF NEW YORK STATE 2002 EDITION. COMPLIANCE IS DETERMINED * ` < F- ) o BY USE OF NEC-CHECK, COMPUTER SOFTWARE DEVELOPED BY DOE, BEDROOM 2 14.88 31.43 7.44 17.65 FLOOD ZONE '' " < ch BATH 3 +_~ 4.80 5.09 + ARTIFICIAL 2.40 2.94 + MECHANICAL Z p U AND CONFORMANCE TO GENERAL PROVISIONS OF CHAPTER 5, A-5 ELEVATIONS BATH 1 4.64 5.09 + ARTIFICIAL 2.32 2.94 + MECHANICAL COMPLY WITH CHA:-'TER "46" SECTION 502, 503, 504 AND 505. BEDROOM 3 11.44 24.06 5.72 13.34 FLOOD DAMAGE Pf ,-VENTION SIpNP�- INDIVIDUAL (DISCRETE) MODELS PLANS DERIVED FROM THIS BEDROOM 4 _- 10.72 24.06 5.36 13.34 SOUTHOLD TOWN '✓�rDE• SYSTEM AND SUBMITTED TO LOCAL ENFORCEMENT OFFICIAL IN E-1 FIRST FLOOR ELECTRICAL PLAN BEDROOM 1 19.28 24.06 9.64 13.34 NOV 11 3 2006 CONNECTION WITH BUILDING PERMIT APPLICATION SHALL BE BATH 2 ,_ 10.88 3.20 + ARTIFICIAL 5.44 0.00 + MECHANICAL K REPORT INCLUDING THE IN- BATH 4 3.52 12.06 + ARTIFICIAL 1.76 6.67 + MECHANICAL NEC-CHECK T R K STATE ACCOMPANIED BY A MEC ( E-2 SECOND FLOOR ELECTRICAL PLAN BONUS ROOM s.4o 7.oi 3.20 4.02 AMPLY WITH IH ALL CODES OF NEW W Y O N -- SPECTION CHECKLIST) MI DROOM 7.22 0.00 + ARTIFICAL 3.61 18.33 'THE PLANS AND SPECIFICATIONS OF THE PERMIT SET ARE DERIVED YORK STATE & TOWN CODES S T A1yIP 0 F APPROVAL ; E r�C ,���dD CONDITIONS OF � . �� M FROM AND CONSISTENT WITH THE PLANS AND SPECIFICATIONS T-1 TYPICAL SECTION AS REQUIRE ASSOCIATED WITH THIS APPROVAL ON FILE WITH THE DIVISION SPACE RESERVED FOR THE NEW PORK STATE STAMP OF APPROVAL 04 a AND THIS CONDITIONAL APPROVAL LETTER.' SOUTHOLD TOVI'N ZBA a TONIN PLANNING BOARD A :760 `L� z l�'O I� J�� " a T-2 TYPICAL SECTION SOUTHOLD ADDITIONAL I N F O R MA T I 0 N PLUMBER CERT''-'„ATION SOUTHOLD TO'INNTRUSTEES DATE:_112#1. - a - TYPICAL PLUMBING LAYOUT ON LEAD CONTLI _�,. asE P 1 N.Y.S.DEC FE'�•-�- .�'-..�77"`^-�.�.� � s� ROOF SYSTEM DESIGNED FOR UNBALANCED CERTIFICATE OF OCCUPAlV0Y N:,l IF`l BUILU1'"d L,t '",r.: `'-NT AT �v SNOW LOAD WHERE APPLICABLE _-4''X6 EXTERIOR 7{JC I6 l '1' i_I h 'P.!. i-LiP Ti L 2'X 6' EXTERIOR 2•X 4' INTERIOR 2'% 4• MARRIAGE STUD HALL SOLDER USED IN V6,: r;:,4 STUD HALL PARTITION WALL STUD MALL °fN SUPPLYSYSTEM CANNOT r FOLLG' -- D0 NOT tf rOCEED WITH 1. HVAC t ELECTRICAL NOTES - EXCEED2/100F1% LEA©. FRAMING UNTIL SURV�.`>' FC`'T 2•X 12• HEADER OF FOUNDATION LOCATION 2. ROUGH - F F.`.t".':: F_U .,�I;l0 ANY HVAC SYSTEM, OTHER THAN THE ELECTRICAL BASEBOARD AND/OA 2"x e• HEADER MICRO-LAM HEADER HAS BEEN APPROVED, 3. INSULATION HOT WATER BASEBOARD HEATING UNITS SHOWN ON THE FLOOR PLANS, 3- 2•% I2• SUPPLIED AND SITE INSTALLED BY THE BUILDER z'% e' 2•X 4• "/2'" 4. FINAL - CON R!_I IC d !.',UST ® N H BE SU ON FLAT NICFM-A" I 1• SPACER �7f Lk E F(",;,] (�• QPl SHALL 3/4' SPACER CMXR DRYWALL BE CO N DOODLE LAVE N 0E oRYWALL DRYWALL UMBING RETAIN STORM WAT' - i/2" PLYwoo .- ALL CONSTRUCTION' SF{,-L I P,i�:.ET THE 2"x 4' JACK STUDS 2•X 6' JACK:STUDS ALL PLUMBING ELECTRICAL REQUIREMENTS FOR SERVICING HVAC SYSTEM BY OTHERS 2•X 6• JACK STIRS DRYWALL & WATER WASTEREQUIREMENTS 0= FIE CODES,OF i`JEW .� �'" ER LINES PURSUANT TO SECTIc HOT WATER HEATER TO BE SUPPLIED AND SITE INSTALLED IN HEADER (EXTERIOR WALL) HEADER (INTERIOR WALL) HIo HEADER (MARRIAGE WALL) Hi3 HEADER (EXTERIOR WALL) TESTING BEFORENEED OF THE TOWN CODE. YORK STATE. NOT RE PC)riSIBLE FOR THEBASEMENT BY-THE BUILDER IF NOT LOCATED ON PRINT(S) "' NO SCALE H8 NO SCALE No SCALE No SCALE COVERING DESIGN OR CONSTRUCTION ERROrl 2'X 6' EXTERIOR 2"% 3' MARRIAGE 2'X 6' MARRIAGE 2 X 6' INTERIOR <- 4 PANEL BOX LOCATIONS) PER PAINT ARE PERMENANTLY MOUNTED BY STUD WALL STUD WALL STUD WALL PARTITION WALL Q` 1 ALL CONSTRUCTION SHAf.I_ HAVEN HOMES, INC AND MEET OR EXCEED THE MINIMUM REQUIRED N _ r `cj MEEK'THE REQUIREMENTS 0 ;� SERVICE SIZE DEMAND OF MODULAR UNITS CODES OF NEW YORK STA-, :.:. SERVICE LOCATION(5) PER PAINT ARE TEMORAAILY MOUNTED PANEL 2•% 6• HEADER ) MICRO-LAM HEADER MICRO-LAM HEADER BOXES E LOCATION(S) N( HOUSING MANUFACTURER AND FINAL CERTIFICATION THIS DRAWING i s THE XCLUS I VE OF 3-2-X 6' 1 f/2'X 0 V2 NIA/ �2' ON%FLAT �Ve �� NAILIN OF AND SHOULD BE USED EXCLUSIVELY YELY t- INSTALLATION IN BASEMENT IS THE RESPONSIBILITY OF THE 1• SPACER ,c` W- bcCUPANCY & BY HAVEN HOMES INC.BUILDER IN THE AREA OF SERVICE LOCATIONS) DRYWALL /z• PLYNDDD DOU�LE LAYER DRYWALL � , �, V T, 7 . Iat i/2 PLYWOOD OR RE r ` ' ,z Frx JACK STUDS 2'X 3• JACK STUDS DRYWALL 2"% 6' JACK STUDS DRYWALL F ) INC. RESPONSIBILITY IF NEITHER PANEL BOX LOCATION OR SERVICE LOCATION ARE TRIPLE LAYS i USE IS UNLAWFUL HAVEN HOMES. HEADER (EXTERIOR WALL) HEADER (MARRIAGE WALL) HEADER (MARRIAGE WALL)LYW00 HEADER (INTERIOR WALL) " LIMITED TO FACTORY BUILT PORTION CALLED OUT ON PRINT, PANEL BOX TO BE SUPPLIED AND SITE M2 No SCALE N9 NO SCALE NO SCALE "Is NO SCALE WITHOUT CERTIFICATE ONLY. i INSTALLED BY THE BUILDER - OF OCCUPANCY 1 0 o 71'-6' o m � 0'-0' 27'-6' .� • 13'-9' 13'-9' a n 5'-0' 8'-9' 9'-6' 23'-8 3/4' 10'-9 1A4' 10 112, 4'-1 1/2' 5'-0' 3'-9` 6'-3' 5'-0' 4A . m 2 H1 TW3052 t H1 TW3052 2 4T) A m ® m i BEAM SUPPORT J2 I N N !2DPGK (4) STUDS N I 2 izo SLIDER AND AD 1 1 x 9 1r4 FAMILY R 0 0 M.L.B.. HEiADER 5HINIPPED L005E SITE IN51ALLEP BY BUILDER WALL I VAUITID TO ABOVE PLUM G BING MOUNT o I 2 52 DROP BEAM SUPPORT 1 H2 N2 H1 TW20210 TW20210 (4)I STUDS N2 6' SLI A 1 8'-3, ��� /"> iO'—s. N1 I LLI B 6' SLIDER 19'-0' I w O I SERVICE 17'-11 1/2' 6 1/2' _ I ___il -- " I 1 1 I " I _ 16-7 ._____J I'-0 7 4112 4-11 112 LOCATION PLUMBIC - Lu RANGE jL—_ SPACE \ OROP —� r— - L--� I < V , ..� All FUEL w 112' SHEATHING \ I . 1 \ I FIDE �[ I I LOCATION DTSNNASNE� \ I� BEAM SUPPORT I I DINING R 0 0 M -� , --_ �_ K I r c H N \ (4) STUDS I I i iRA LABEL AND STATE LABEL z I I , I I ARE LOCATED IN VAPITY I cD Z I ( I IRA LABEL, 5TAT LAB L I I` D R E � �� /�� � sl I I IN BATH #4 i .. '�' O i ( ( I AND DATA PLATE LOCATED I I W R L _ ^ l I w ch IN COAT CLOSET IN FOYER I I / \\J_ ,,, �' - I I I [2'-1 1/2' I o T_____ / I \ N� O� IDI 1 ( .4l I 1 Z � < m Z V // \\ N Hl w cfl Ju °L Nbe N I I I 0 o C) scow �_ BEAM SUPPORT I BEAM SUPPORT i 2z4 WALL I u °C m NOTE: BYTTHENBUILDERTSBUILDERETOAND FIELD IE DTVERN�AIIED (4) STUDS I = (4) STUDS I 2z6 WAIL 2.-0, I tD 46' TALI ALL DIMENSIONS BEFORE CABINETS ARE PURCHASED `D IL \. i I � T (3) 3' PVC CHASES HALF WALL I/2' SHEATHING N8 2/6 B L'ENi 10 A111G r REFRIG _-- — —�ANtRY —TUIILITY 3� AATE➢ OR BEAM U51UDS i PPORT 518' TYPE Hi wP 53 BEAM SUPPORT DOUBLE 2x4 LOCATION _r--- CABINET jCABINEtj I '>i' FIREGUARD (3) STUDS RKIAGE WAIL �" CABINETS BY 10'0'_ARCHWAY_—_—+`__ T _ 4'0_ARCHWA ip / I I I I BUILDER ONSIIE -------m7TIT z 11-i14' ------ , ------- ON 216 1 6'-ii 71B' i 3/0 1 M.L.B. EACH UNIT BE SUFFORT d 10 DOUBLE 2x4 -- — RRIAGE WALL 53 I MUD ROOM 112' SHEhiHING ® ® 12'-i1 112' --3'-4 3'-? 718' 6 314' i H13 c? 6IW5UN 5T6224 5IVPP 5l7PLIEV A}D i SITE 185iALLIP TO PENIiLII'Dwo UNITS o� (2) tRA LABELS "' 2 SET A PEIOxYloG�'xx*UNNE RAVR N 5SUEH SET STATE LABEL AND - DATA PLATE �\\ /^t lo` ( of �a � j_ 6 h R A G E Zj \\\ //� GARAGE TO BE F.ACi ORY MILT i� o LIVING ROOM m =_ N '1�\ \ / I I o BY HAVEN HOMES, INC o �2> I/ i \ \ �� I �' Im - GARAGE SLAG TO START 24" `� n 1 ,aFOYER 1 / \ << I {I } d- Z 1- L H8 - BELOW FIRST FLOOR FINISH 4 w . N 3 00)L 2'-11 1/2' ^� - COMMON WALI BETWEEN GARAGE N < d- I < _ o 11= i� o AND HOUSE REQU I RED TO BE '` I I� K•x� FINISHED WITH 51C3` FIREGUAR � o m H2 i i UP GARAGE CE I I I NO REQU I RED TO 1►2' SHEATHING - H8 1 D N BE FINISHED WITH 518" FIREGUARD H 33 i 16' 11 112, 12'-5' "' d 2/6 0 HB 112' 5HEAtHIN I o 2/6 H8 c L3O BATH 14 518, TYPE TW3052 TW3052 ENTRANCE TRIM TW3052-T EHED TW305z 'f(' FIREGUARD w N1 Nt N2 Nt H1 1 (2) TRA 2 5 LABELS i N 2 3 O° 7 PORCHf J BY BUILDER ONS I TE WINDOW AND (3) 1 I 1!4' �p 6-i1 718 CROWN MOLDING I IT 11 1/4' M.I.B. HEADER " a ON LINEN CABINET Lz— (4)SHIPPED 1005E SITE INSTALLEDBY THE BUILDER7'-3 7'-0 4'-0 7'-6 4'-0 7'-0 7'-3 I5HEh1HING I BEAM SUPPORT BEAM SUPPORT F4w�YL192184+f (4) STUDS 51UD5 T TW3052 HI TN3052 TW3052 Is9 P 1 52 N I 4'4' 6'-4' 11'-4' 11'-4" 6'-4' 4'-4' 3'-9' 10'-0' 10'-0' 44'-0" 27'-6' oa Ile ... 1 I R 5 T 1 L 0 0 R F L A N PROJECT SPECIFIC INFORMATION GKEENPORT. NEW YORK NOTE TO BOLDER: t ^� 7 OF Nt--Gjr c' 4'-O' FINISHED GEILIN6 HE160T UNLESS NOTED OTHERAISE 120 MPH WINDZONE (3 SEC GUST) All HOLD DOWNS, STRAPS, NAILS, SPIKES, U 4�' r c�'��$J.PNti4•rAlgp�p� 7'-0' 111NDON HEADER NE16HT UNLESS NOTED OTHERNISE EXPOSURE 1c, STAPLES, OR ANY CONNECTOR CAN BE 6UB511TUTED Fs >- .y aON 45# PSF SNOW LOAD WITH EQUAL OR BETTER HARDWARE t "TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT" " o SHEARWALLHORIZONTAL 51RAP CONNECTING,41000LARS GABLE END FACE: WINDOW DP INFORMATION 15132' CDX OR 055 (EXP i)OVER FRAMING W1 112'GYP' INTERIOR ❑1 PROVIDE'SIMPSON' 516224 5TRAP 0 GA LE END RIM BAND 0 15T Ftt. DIAP n - WINDOWS USED MUST MEET THE REQUIRED RED PLY NAILING: 8d NAILS 0 2' E.H., 12' F.N. (E.N. SHALL BE STAGGERED)OR SUPPLIED AND SITE INSTALLED BY THE BUILDER UNLESS NOTED OTHERWISE THESE PLANS (AND SPECIFICATIONS) ARE IN COMPLIANCE WITH ENERGY 7116' z 2' x 16 Oa STAPLES 0 P E.N.,8' F.N. (E.N. SHALL BE STAGGERED) 91 CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE. 2002 EDITION. DP RATING WITH A MINIMUM OF DP-46.85 �� 67 NAILING: 5J MAILS 04'E.N., 10' F.H. OR EQUIV. l 074252 - SKYLIGHT USED MUST MEET THE REQUIRED 3X OR (2) 2X 511LI MEMBER RECEIVE EDGE HAILING 15T FLR RIM TO CONCRETE FOUNDATION HOLD DOWN: AR COMPLIANCE 15 DETERMINED BY THE USE OF MECcheck , COMPUTED SOFTWARE DP RATING WITH A MINIMUM OF DP-34.97 TYPE IIPERF RATED SHEARWALL F2 FROVIDE'SIMP50N' STHD14RJ HOLD DOWN0 EA. GABLE END P05T OFESSIONP�- DEVELOPED BY DOE, AND CONFORMANCE TO GENERAL PROV 15 I ONS OF - PATIO DOORS USED MUST MEET THE REQUIRED AVOWABLE SHEAR=951 PLF W1 REDUCTION 5UPFLIED AND 511E IN51ALLED BY THE BUILDER NOV 1 205 CHAPTER S. SECTIONS 502, 505, 504 AND 505. DP RATING WITH A MINIMUM OF DP-39.56 5HEAR WALL-53 NEW YORK STATE BUILDER CODES (2) 11132' CDX OR Ill(EXP 1)OVER FRAMING THIS DRAWING 15 THE PROPEKTY OF, PLY NAILING: 101 HAILS 0 2'E.N., 12' F.N. (E.N. SHAH BE STAGGERED)OR I ND I V I DUAL , (d l c r et e) MODEL PLANS DERIVED FROM THE SYSTEM AND - 2002 RESIDENTIAL CODE OF NEW YORK STATE 1116' z 2' It 16 Ga STAPLE50 V E.N.,8'F.N. (E.N. SHALL BE STAGGERED AND SHOULD BE USED EXCLUSIVELY SUBMITTED TO LOCAL CODE ENFORCEMENT OFFICIAL I N CONNECTION - 1999 NATIONAL ELECTRICAL CODE 3X OR (2) 2X 51LL1 MEMBER RECEIVE EDGE NAILING BY HAVEN HOMES, INC. ll uu - ENERGY CONSERVATION CODE OF NY$ TYPE I I PERFORAiED 5HEAMALL ll UJI WITH BUILDING PERMIT APPLICATION SHALL BE ACCOMPANIED BY A 2002 EDITION ALLOWABLE SHEAR=2002 PLF WI REDUCTION z HAVEN HOMES, INC. RESPONSIBILITY � 4A MECcheck REPORT ( INCLUDING THE INSPECTION CHECKLIST) LIMITED TO FACTORY BUILT PORTION ONLY. _..------.------ ----------- I�-{I t ` 2�•. r _.. j 1 � I l ----.-----------— ---- t kf t li }�_ .. L----————— ( __ ! i � _ t _-.._....._ t !4' '-1'= �r'r � '� %• ..:' - KEY I I OtS RATS ^D• STERK XE6 RENQE �c� ;�- �-e6 n>?P arc LI�HrS -- s`� - 09-21-!?IS t ,.� := •: CU3TOM'EK 7tRC1fE55 - -- t'" , 't 4 a.p Dial 11114M -'I�ECP;AO©EQ-ClR: Q -- .� iLAYOUT Q Yy ROAD t�LA+ �'�il�Ef DRAWN 15Y ;� 'a, f64 KEMP.'•BLVD — -- — -- `• „" .�...,, ." _ JC6 �t-93-0f -- YrHIRIP_U�L-SWEiCfIE6_ CREEK PA 16822 JCB " K'>, h. �CREENPo T, NY f5T0) 462-3181 (PAX) ----- -- --SECOND _FtWE.ECTRI I CAL.` "} POa 1 L L i CQ CONSTRUCTION NOTE TO BULDER: ALL HOLD DM5, STRAPS, NAILS, SPIKES, SHONEk NEA9 Cry SNpIEk STAPLES, OR ANY CONNECTOR CAN BE SUBSTITUTED o ao•ATE LA6lO5LRE SUPPIiED Sm HEAD x WITH EQUAL OR BETTER HARDWARE [AND SITE 195TALIEP Od0'AFT N 1x DY THE BUILDER I IxD o SHEAR WALL-51 r14- 15132'COX OR 0 5 f 1) OVER FRAMIN6 WI 112.6YP' INTERIOR PROVIDE'51UPSON'5T6224 STRAP 0 GABLE END FACE 0 ROOF=rLAIE c1( fJSltfkE 2,61RI s w - =8d NAILS 0 4' E.N., 12' F.N. OR 'SINPSON ST6224 STRAP 0 GABLE END RIN BAND 0 FlR DlAP. BUItNOSEu �'� w7116' x 2' z 16 GA STAPLES 0 2'E.H., B' F.H. SUPPLIED AND 51TE INSTALLED BY BUILDER UNLE55 NOTED OT ESE 6 4xt 51 6YP NAILING, 5d NAIL5 0 4' E.N., 10' F.N. OR EOUIV. 6z6 WHITE 10xu 2X SILL/I&ICER RECEIVE EDGE HAILING n st CMIE 2,6 TRI H u � TYPE 11 PERFORATED SHEARNALI 4 PROVIDE 'SINPSON'M5352 STRAP 0 EA. GABLE END F051 6,6 BLUE '• N o AILONABLE SHEAR=615 PLF W1 REDUCTION ❑ CENTERED 0 RIM BAND, POST TO POST, ON SITE U511EkE 6x12EmmaIEEE < s SUPPLIED AND SITE INSTALLED BY BUILDER Ix 4zt t, 4x1 +n m w LA51tfkE 2x6 TRI ,es 6z6WHITE 4A < xpu 10,14 1004 I,10 BIDE tO:U OZ o m w 6ASBIEkE 6z 6x6 WHITE "- fox 14 tOxt4 N ra 10,14 IWO 5IMt PAN N N BATH #3 TILE DETAIL BATH 41 TILE DETAIL BATH #2 TILE DETAIL A BATH #2 TILE DETAIL B �P� I o n�N��,y m NOTE: (2) SHELVES INSTALLED 5 AVg2 �,p xo m m 'a m u u u u u I APPROX. IV AND 30' 2 3 ABOVE TUB DECK k 71'-6' 44'-0' r_ rr � 0?'4252 ��C? 5'-1 112' 6'-0, 9'-0, 9,-0' 9'-1 t12' S'-9' 5'-0, 8'-9' 2'-6' 9 'ONP l.sl "TO THE BEST OF MY KNOWLEDGE. BELIEF AND PROFESSIONAL JUDGEMENT" 3 BEAM SUPPORT N zOOF Z THESE PLANS (AN) SPECIFICATIONS) ARE IN COMPLIANCE WITH ENERGY (3) 51UDS r� p CONSERVATION CO STRUCTION CODE OF NEW YORK STATE, 2002 EDITION. — 4— COMPLIANC� I5 D TERMINED BY THE USE F MECcheck. COMPUTER SOFTWARE I r———— ————- I � Lu DEVELOPED BY DO . AND CONFORMANCE TO GENERAL PROVISIONS OF I I ' I I I04 CHAPTER 5. SECTIONS 502, 605, 504 AN0 505. II ` I I I II 1aZc � z INDIVIDUAL,(dlc ete) MODEL PLANS DERIVED FROM THE SYSTEM AND I 1 ; I I I I I LU m O! SUBMITTED TO LO AL CODE ENFORCEMENT FFICIAL IN CONNECTION I I I I I I I I ,u w e U WITH BUILDING PERMIT APPLICATION SHA L BE ACCOMPANIED BY A FROM 2!nd FLR POST O MECOheek REPORT (INCLUDING THE INSPE(TION CHECKLIST) TO lot; FIR HEADER z ea CROWN MOLDING 4 I I T I ( I I w w 3 c~c 4 ON LINEN CABINET H i TW3052 H 1 TW3052 H 1 T42432 H 1 TN2432 N I TW2432 � I I I I B ———— ------- - i~ --o —`o ------- ----I `�15'-2' o Hg II 6 112'• 8'-1 112' o� o ~�-• � �Y BATH >3 BEDROOM # 2 �N=II!� m�gt2 MALK-IN �FUUMP ACCESS CLOSET -4TRA El BATH WC III WC =W 1/6 518' DRYWALL I I I z m 2/4 `----- 2/4 ._._,. ` -- 4 i BEAM SUPPORT I ' i I J (7 NB HB L < I I (3) STUDS I - N t•-----1 ^w --------J L— O I ATTIC ACCESS I -a,S = -- O 2/6 - j 24' X 36' j 42' HIGH o� 2/6 RIM BAND 0 FLR6DIAP224 SSUPPLEDTRAP 0 GAPT SITE 3 a'ABLE ENO L'`'- I •- @ 2z4 WALL DOUBLE 2z3 L--_—_J HALF WALL INSTALLED 10 BEDROOM#1 UNIT 26 WALL - -- !1 I G RIAGE WAIL ON BY THE HAVEN HOLES 5f1 CREW PRIOR '"--�__�- I to z 2 DOUBLE 2x3 BEAM SUPPORT SHOWER HEAD N H1 HD RRIAGE WAIL I 1 10 2nd FLOOR GARAGE UNITS BEING 5E1 - - m N z O (3) STUDS 80' A.F.F. 4 } I cfl LU c� 4'0' BI-FOLD 4'0' BI-FOLD •—•—•—.. —— 2/6 H9 —.—.—.—. I 1 112' x 20' KONTILLER WHIRLPOOL WI c c N —- :MAMI-II -——— TILE SURROUND WC H9 H9 LOOK JOISTS DOUBL ��4�8344AN NO-DEDICATED © BEAM SUPPORIF 3 (5) STUDS 0— OU1 ET BOX FOR 2'-6 112'ED INST4IE9 5HOWER Ed SURE AND 2/6 H6 CARD N-NONOkIDE R52127 B ICDR 5UPPlIED AND51t 5, H8 CARD DETECTOR PUMP TRA LABEL ACCESS I A INSTALLED BY UiIDER N 10 I I I as 4,-0, I ;l BATH #244 I I 2/4 _ 2/4 12'-1 i" (2) 1R1f�LABE � o0 ry `S' I OUBLE 2z4 BEDROOM #! ----- - -- -- - ---�I =_ \\, RRIAGE WALL / Ht M I o ` , AD30 I YL242104+i'I/ / L_SLOPE_ _� I �' FLAB m, CROWN MOLDING � N -I BEDROOM # 4 WALK-IN FLAT ❑ ® _ N IINEN CAB NE n ` THI 3 # m N8 �' GL05ET LOCATEDU UNDO SINK IN BA1H# NIT 15 BEDROOM 3 TW3052 N1 TW3052 H1 TW3052 TW3052 N2 TW3052 N1 T 52 HULL WINDOWS TO N 4 ACCEPT CDR S86/80 5 4 ... .. SUNBURST ABOVE I �' ttD oa _ a --- ————————————— -------------- ————— L LD .. 6'-4' 11'-4' 11'-4' 6'-4' 4'-4' 44'-0' 27 -6' DRAWING IS THE PROPERTY OF. 71'i' HOULD BE USED EXCLUSIVELY S E C O N D F L. O O R F I A }�, BY HAVEN HOMES. INC. w' +.. I V tx.T 8'-0' FINISHED CEILIH6 HEIGHT UNLESS NOTED OTHERWISE HAVEN HOMES. INC. YRESPONSIBILITYPORTION NI V-8' MINDOM HEADER NE16HT UNLESS NOTED OTHERWISELIMITED TO ONLY. i i ANCHORAGE SCHEDULE ANCHOR BOLT LINE 1 LINE 2 LINE 3 LINE A. LINE D LINE C LIM D 2'x10' FLOOR JOIST 1/2 p �� n p u p u diam x 18�� 12�� OC NIA 24 OC 16 OC 48 OC 32 OC 24 OC 5/8" diam x 18" 16" OC 8" OC 32" OC 24" OC 48" OC 48" OC 32" OC 1 10" POURED CONCRETE n " n n n p " 2 w 314" diam x 18 24 OC 8 OG 48 OG 32 OC 48 OC 48 OC 48 OG 395 WALL OR CONRETE BLK. 718 diam x 1$p p 32 OC 8 OC 48 OC 48 OC 1747VOC 1 48" OC 48" OC W N z o / F N TYPICAL SAYE WALL --TYPICAL END WALL 71'-6 112' L— MEN 2'x10' FLOOR JOIST ARE USED, THE SILL PLATE (BM 5'-0 112" 8'-9' 11'-3' / 2'-6' 'w TIMBER) IS TO BE INSTALLED FLUSH NITN THE OUTSIDE FACE ��� u OF THE FOUNDATIGN HALL TYPI- •. r -------------- ----------•--- ------ -' CAL BOND TIMBER SIZE-2'xO' , A WITH 2'xI0' FLOOR JOIST. I //m, 1 ( r 'BOND TIMM DETAIL � Ifix 10' CONCRETE MASONRY UNIT (CMU) OR I I I o 2'x10' FLOOR JOIST -NO FOAM POURED CONCRETE FOUNDATION WALLL w 10'x 20' CONTINUOU51POUkED CONCRETE ( Z Z 44'-0" �., 5'-0 112' I FOUNDATION WAIL DOTING-TYPICAL j L —i LLI o �`•w I 1 I L—— � cs� c.� B r ------------ ------------------------------------------------------- -- 4�- I jr----------------------------------------------------------------------- = I I w I i I— — o ~ o > V, o < m ( I i 3 112" DIA. METAL SUPPORT COLUMN CENIERE ( tt) 10 CONCRETE MASONRY UNIT (CMU) OR ON 30'X30'X10' THICK POURED CONCRETE I "' m o m oc o w J ( O _ O fu CL p ( I POURED CONCRETE FOUNDATION WALL- TYP. COLUMN FOOTING TYP.. i 1 '- O� " w =` Ul t I � I o I I r-- � m ( 10'z 20' CONTINUOUS POURED CONCRETE BA5EMENT � � FOUNDATION WALL FOOTING-TYPICAL 4' FINISHED CONCRETE STAB OVER I ` 2'-I 112' { 4 CRUSHED STONE OR GRAVEL i ✓ I ----------J L----1 r— i --------=`�-----------------� a 21 I t 1 1 1 j N I l— —1 �� l—. � —- �------•--� � f i 1 � I '�, i 11; i I l 112' PIA. METAL SUPPORT COLUMN CENTERED I I 1 I z N 30'X30'X10' THICK POURED CONCRETE COLUMN FOOTING 1YP. I I Lp GARAGE ( III mm � <�I I � I z I I I i I ( UNEXCAVATED ) l i i I Q < �- N < m ( o a> o n c lu 4' FIN15HED CONCRETE SLAB OYER ( I I I I I I I I 4' CRUSHED STONE OR GRAVEL I I M 1 I I I I I I II I I 1 I I II ( I o I i i I i II u I I I I I a " 10 CONCRETE MASONRY UNIT (CMU) OR POURED CONCRETE FROST WA tYP. • Icc _' —-t I I I 1 I � "c • I1 C 0 L —————————————————————————————————————————————————————————————————————---—� I I 10 z 2 FROM WALL FOOTING-1YPIC I I I I ' CONTINUOUS POURED CONCRETE I I I I I a Al `` � PA o e` OUNPTION Ir' LAN _ZP I I I I I NOTE: ALL DESIGN NOTES AND DETAILS ARE I I I I I I I T V SUGGESfIVE ONLY. STATE ANDIOR LOCAL CODES I 1 HAVE JURISDICTION IN DETERMINING MINIMUM I I I I I I I --------- , L-------- ' ------------ -----� SUPPORT REQUIREMENTS. L I � 44'-0112' 27'4' C o 71'-6112' --- .. A. oh F "TO THE BEST OF MY KNOWLEDGE. BELIEF AND PROFESSIONAL JUDGEMENT E THESE PLANS (AND SPECIFICATIONS) ARE IN COMPLIANCE WITH ENERGY OF N �P . Tq��o CONSERVATION CONSTRUCTION CODE OF NEW YORK STATE, 2002 EDITION. � H�► �ya� gPF0 COMPLIANCE IS DETERMINED BY THE USE OF MECcheck , COMPUTER SOFTWARE DEVELOPED BY DOE, AND CONFORMANCE TO GENERAL PROVISIONS OF CHAPTER 5, SECTIONS 502, 503. {�?�; ,��504 AND 505. THIS DRAWING IS THE PROPERTY OF,AND SHOULD BE USED EXCLUSIVELY o C���� INDIVIDUAL (DISCRETE) MODEL PLANS DERIVED FROM THE SYSTEM AND c�4252 BY HAVEN HOMES, INC. ww SUBMITTED TO LOCAL CODE ENFORCEMENT OFFICIAL IN CONNECTION WITH 9�FESSIONP�-� HAVEN HOMES, INC. RESPONSIBILITY ty, BUILDING PERMIT APPLICATION SHALL BE ACCOMPANIED BY A MECcheck NOV I Ub LIMITED TO FACTORY BUILT PORTION REPORT ( INCLUDING THE INSPECTION CHECKLIST) . ONLY. OG O CONTINUOUS R106E VENT tt� V c� O OC L 2 CONTINUOUS RIDGE VENT N z Z to 12 0 2 PITCH cn to w t' sat to N 1 m CDM 586180 FINISHED CEILING 0 LL LLI o o — h- -- FINISHED FLOOR 12 z j 8 PITCH Lu v' O FINISHED CEILING o > O z p < toaz Z t > l Ll z lu J W O mow —t O C7 W sL a w tf� 04 o I UA FINISHED FLOOR -771 GRADE � FRONT ELEVATION Z o -" @ ° Z < Us - w 3 y N to Lu 12 � � il- o rno -3fl ul 7 PITCH h = FINISHED CEILING w (s O LL. a w — 0 Z 3 @ �'+ a+► w w t- O < s ch ch wWwO wow �' 0'. c a � Z � NOtA OZ } 12 _ 0 to PITCH 9 (a < h Y nc z w tsi w — < � sL 7 - - CJ u_ J h o� o z FA � o u < u- < !2 FINISHED F100R p. Q04ujwto o � o � PITCH < z u- Q) - o a hz FINISHED CEILI �n u. ww oz w ww — w nczwV- < aft-- ta = � OF N�1,r, < u_ a w d� o Lzu -j .�P��QN M. w O Um Z _tZ m zw = Q � < Lu < 0 (p N oah � � ac � � '.y ate. o < QM. W) wzoaw. lu Q ch — omo - OwhZ rn O �74252 "y u. — wUN Mw < — w O — l- Z m fl V Z UU -- t] tn �O — w RGFESSIONP�-� � to wc» = u. 8L AC < (n h 9" {-- o ci rw- - o DZ < < 0 140V 200 aZww ^ UCH Z --J U. 4oaoa � ct� oho - --FIF FIR15HEDFLOOR 0 w a � � THIS DRAWING IS THE PROPERTY OF. Ow _4 AND z o w tm o h Lu Z GRADE BY HAYENLHOME SUS I NCEXCLUSIVELY ul to < htJ � Lt1 < � — w —I < zw = lu w tL > < Ac a t- z HAVEN HOMES. INC. RESPONSIBILITY (n � � � � o LEFT ELEVATION LIMITED TO FACTORY BUILT PORTION o wzM < ato — t ONLY. L H- zoowx z = = w hU V a — 0) tow N CONTINUOUS RIDGE VENT w z Ul CONTINUOUS RIDGE VENT z ls] � N m U. FINISHED CEILI � a F-1 12 - PITCH 9 0 m 1st ca z z Lu 0 10, — c� - - FINISHED FLOOR z cs� 1.0 u1 O FINISHED CEILI z p t . n — O o lu —t ■ O w (Si aL in � o O o ca I FINISHED FLOOR GRADE REAR ELEVATION 12 -I o PITCH 7 -n m I z Q 1u * w N 3 ta 3 w v < apt U -� to �'- 0 0) o " P4 FINISHED CEILING w Q }- • 3 s C4 z >- z1- �- x w tDoIL n v .. tom! 4a m oz — o z3 w w �- U) (1) z — u_ z o N n wnoc0 gOC� � p, a � Sw1w- tA 1w- 1- � � V 12 '-• 3 m m — 0) z a 9 PITCH � � z N 0 cn z >- o_ w Q w o to � as U > Y V lA Z w -o F- n U x DC Z w s 1 no[ -A < FINISHED FLOOR OG o Q u_ 4 9L " co.� ncwwln n � oci �� z_ }o- �w 0 > u- Q -j FINISHED CEILING �oa u.. w swig o o z lu Ul s i w aczwE- e oa- ms OF N�c 4 Z u w .�IL 0 w -1 P�� 5� �QH M. rq�q y0 �a'a� rn m wz � < w4O �} �Fs�� o a z ul .a c� s — O n 1- � - a. nc 0 1- w — 0 9t to a t7 1- c) >- oil JU. Zw �C o Q nu_ u') wzol .. w Uz z 0w -- tl3 � N — ono O u. wuW � nU - S�OA ��4252 �L w � � zw wU - S 9�FESSIONP�� sL w OC d n z w w o z FINISHED FLOOR 140V 1 .3 20OF u- z0a401- 001- - O QU0n1U cl m= Lo � �z — � � ._.o � � THIS DRAWING 16 THE PROPERTY OF. w z o w � - I.- w w Z GRADE BY HAYENLD BE HOMESUSENCEXCLUSIVELY w cm < t- c� n � en — -4 < zw mwt9 -- w w 9L. >- < b- L n {- Z j S w w o +w- > ~ n OZ R 16 �1 T E L E V A T 1 0 N LIMITED OTOSFACTORYRBUILT SPORT I ON 00) n` wh- o wzm > d oto — a. ONLY. 1- soowx z = aw 1-- QQMQ - chtoC14 ELECTRICAL SCHEDULE Circuit Description Cir No. Breaker Size Wire Size Remarks Circuit Description Cir No. Breaker Size Wire Size lRemarks General Lighting 1 15 Amp 14-2 W/G GFI W/P Rnage Hood f7 20 Amp 12-2 W/G General Lighting 2 f5 Amp f4-2 W/G Dishwasher f8 20 Amp 12-2 W/G Bathroom Recept. 3 20 Amp 12-2 W/G Bath GFI 19 �2 General Lighting 4 15 Amp 14-2 W/G Sm Det Furnace Swith 20 20 Amp 12-2 W/G General Lighting 5 15 Amp 14-2 W/G Clothes Washer 21 20 Amp 12-2 W/G Bathroom Recept. 6 20 Amp 12-2 W/G Bath GFI Clothes Dryer 22 30 Amp 0-3 W/G Appliance 7 20 Amp f2-2 W/G Din Rm 23 Appliance 7 20 Amp 12-2 W/G GFI Am Garage 24 20 Amp 12-2 W/G GFI W/P Appliance 9 20 Amp 12-2 W/G GFI General Lighting 25 15 Amp 14-2 W/G Appliance 10 20 Amp 12-2 W/G Refrig Bathroom Recept. 26 20 Amp J2-2 W/G Bath GFI _0 0 General Lighting if 15 Amp 14-2 W/G Arc Fault General Lighting 27 i5 Amp 14-2 W/G 0 General Lighting 12 15 Amp 14-2 W/G Arc Fault General Lighting 28 f5 Amp 14-2 W/G �. m General Lighting 13 15 Amp f4-2 W/G Arc Fault General Lighting 29 15 Amp 14-2 W/G LU N General Lighting 14 15 Amp 14-2 W/G Arc Fault General Lighting 30 15 Amp 14-2 W/G Exterior Recept. 15 15 Amp f4-2 W/G GFI W/P General Lighting 31 15 Amp 14-2 W/G Electric Range 16 40 Amp 8-3 W/G Elec. Whirlpool 32 20 Amp 12-2 W/G GFI Whirlpool 33 20 Amp 12-2 W/G GFI Whirlpool 34 20 Amp 12-2 W/G GFI CIR#3 , DEGk r� CIR#29 i CIR #29 CIR 129 j 1 4 I 4 -0 Q') —. CIR 130_ .—. CIR#30 I LU O r� cIR #3o FAMILY R00 WALL I CIR #29 I >Iu r- MOUNT IQZ CIR #25 CIR#225 / �� ^I I I w o / � I t- w U CIR #7 ""I. E-1 04 CIR IfSERYICE CIR#7 33 GFI #9 � - CIR3 IOD I--�-� 1 �`•II :., I wBREAKPAStJ�. CIR#8 �/ \�� I w �4 -0' 11 -0 - f r- -- y :� - - l IR 15- I • ` /I'/ \ CIR #29� I O oc o w DINING ROOM CIE17 I I CIR #11 \ IR #25 ROOM j \ I I I = —_ .� ISIIIIh51EA �\ \�i i I Op O� oO us w a _ I CI #5 �,. \ I I I �t GIR #25 i a� o GFI #9 \, CIR #5 i' --• V-10 112' <.'^\ �` I I —.—.—. I �. \ CIR#5 I �' I —c- �' I I I I i I �' Q. m CIR#25. ——— —� FIR#g5 I ' �p 7-6 tl2' ~- 3'-6 112• 3'-6• N CIR 125 1 I I CIR#2 /i GFI #9 i "' K I T G H E N i-- ( IR 125 ! ` i 4'-9' 11'-3' 6'-0' 4'-0' I HIGH IN CAB N5TALlED BY I I I i I I _ •—•—— I CIR#5 BUILDER GFI #9 c'// \��� 1 I GIR#3D i CIR #30 k4_14 I GIR #7 i "' CIR #25 i'/ \�� i N i I I IR#5 GIR#5 INSTALLED BY ! �J y� i / I I I I GFI #9 I 17J I BUILDER GFI 19 1'-6 112' 8'-3' 6'-2 112' 6'-5 112' —-- fl_` .�/.—._. _._ .-_.—.— -- ' SWITCH TOP CIR 125 \ �.\OR 125' j HIGH IN CAB ------'�'� \\ V m CIR 129 I CIR#29 HAI,= -CIR#29 I \ INSTALLED BY �. --.—.; —. �'�. ' _.�. Q 31 BUILDER GFI #9 JCIR�' CIR #5 I /�-f CIR #5 --"' CIR#9 m 3 N c� \�II% --- r- ----- ----- -----IR19 NON-DEDICATED i �'-''—' —'�, I I I I CIR #4 OUTLET BOX FOR CIR 17 O CIR #7 CIR #9 ounE1D01 FOR +"' ~^ © BIDR. INSTALLED 3 3 t BlOR. INSTALLED a / = I �; "' I I I CARBON-MONOXIDE a _ _ CIR #4,1, \ DETECTOR I us --- ------------------ - 6AtmN-+IDNDXIDE .-.w ——— ------------------ _ DEiESiDR - -- CIR#1 _ -- b 3 GIR#4�,�. -"� GIR #2 CIR #2 -T- -'°' m ———— ' �1 O CIE If 1 I I MUD(ROOM -- , ' n_. .i © � FURNACE SHUT-OFF _M -+_ _-1— — ——--———•- .,- �, CIE 124 _II CIR#4 1 SWITCH CIR 120 I 1 �' m �" - 6'-0 3-10' CIR #i CIR#1 � III f �`� CIIR#2 I i CIR�24• •----^•—•—•—• � : � Z. z � �- —•---—.—— — �u �/ CIR#i oW -- T67R#22 -� I i / < +� V ri GIR #2 ^ CIR #2 n i i c"n •- c m o owl GARAGE - LIVING R 0 0 M \ % CIR 4 I ( w o I ��\ /�' I _; II i CIR #24 i I -� I y_ % �'—. I I o CIR#2 I CIR#2 GIRI#21 II I i I I II ! FOYER ( I �' ..�I i 6-10314' i i i ' J � � CIR #24 I I CIR #2 CIR#2' N a' m '�- N IR#1 CIR 11 I I / CIR#4 �. \�` I I 0 ., CIR 11 i i I��/._.•-•--•---• •---•�...._•`\ � ------•—•---•— -.i GIR# I I CIR 124 ^ :� ( CIR 11 CIR #1 '� 43 CIR 12 CIR#2 O� "" E RANCE'1RIM BATH 14 CIR #1• o•-�l � ... GFI 126 i CIR#24 PORCH COILED WIRE FOR PORCH l •� I r�LIGHTS CIR #31 (WP)- , N i COILED WIRE FOR PORCH CIR#24 CEILING FANS CIR 131 (WP)`-- I �_ I � CIROF # 4 I n �'• \ �, N I R 5 T F L 0 0 R E L G T R I G A L F L A N �P �QN M• Tq�9 {�� , LP ,F .• ;a � w a 1 ,.THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGEMENT" � tit � n )-- SINGLE POLE SWITCH I� TELEPHONE JACK � DUPILEX OUTLET CEILING FIXTURE E PLANS (AND SPECIFICATIONS) ARE IN COMPLIANCE WITH ENERGY m ri < \ / > ERVATION CONSTRUCTION CODE OF NEW YORK STATE, 2002 EDITION. 2 THREE WAY SWITCH TELEVISION/CABLE � SWITCHED OUTLET WALL MOUNT FIXTURE \`� /'� FOAL°�a252 WIRE FOR PADDLE FAN CrE5Si0N�' LIANCE IS DETERMINED BY THE USE OF MECcheck , COMPUTER SOFTWARE FOUR WAY SWITCH WEATHER PROOF OUTLET PULL CHAIN FIXTURE � \�` NOVZQ ti SERVICE PANEL <„/ \„> @ �� LOPED BY DOE, AND CONFORMANCE TO GENERAL PROV{S 10N5 OF Efl— DOOR JAMB SWITCH GROUND FAULT OUTLET =__= FLUORESCENT FIXTURE TER 5, SECTIONS 5A2, 503, 50h AND 505. ® SMOKE DETECTOR BREAKER PANEL 220`V OUTLET ® RECESSED FIXTURE � �'�' THIS DRAWING 16 THE PROPERTY OF. AND SHOULD BE USED EXCLUSIVELY VIDUAL , (d{crete) MODEL PLANS DERIVED FROM THE SYSTEM AND © CHIMES Q EXHAUST FAN ?---� CABINET FLUORESENT T TRACK FIXTURE WIRE FOR PADDLE FAN BY HAVEN HOMES INC. w; ITTED TO LOCAL CODE ENFORCEMENT OFFICIAL IN CONNECTION RECESSED EYE BALL F '� `�` W/ LIGHT KIT BUILDING PERMIT APPLICATION SHALL BE ACCOMPANIED BY A ®EXHAUST FAN W/LIGHT EXTIERIOR LIGHT (WP) UNDER CABINET FIXTURE HAVEN HOMES, INC. RESPONSIBILITY n Q to heck REPORT INCLUDING THE 1 NSPECT I ON CHECKLIST) GANG BOX SWITCH QQ THERMOSTAT s/ SMOKE-CARBON MONOXIDE HOLLWOOD LIGHT LIMITED TO FACTORY BUILT PORTION �uui DETECTOR COMBINATION aka ONLY. i m w ct c ch O Z O N uj I� N I to c r II I I II w II I I tl z z t,-- j � ,a � �-- o ' �- o ------- --- --I ------ I ---- ----------- T--- - r--i-- I--- i zp < X Z c� II CIE #27 ° �` — CIR 112 CIR 112 I I 1 t I I I O c3c o to .ems I I I I o fl- o � z � 4 Q \• BATH #3 I. CIE#27 I -~ BEDROOM # 2 .\\ GFI #3- I I 1 I I I * w � o r � \ 1' i CIE#27 WALK-IN I \ I I I b.- CIE#12in \\\ _— CLOSET 7'-l0' ❑ IR #12 ! I CIE#27 CIE#54 �\ ' ° I ❑ I I I - ---- BATH $I CIE #27 ��\\ ' \ CIE #12 \ `� CIE #27 GFI #3 \ / CIE 112 CI #. CIR 112 i L __ \ CIE 127 ; CIR #4 GIR #11 LIR 111 I I ( I I Q •� \ •\\CI #t2 � ' �• - I --------- ---------1 GIR 112 1 I - CIR #4 CIE #4 __ 7'-11' AMC LIGHT /- 5-10 4-0 2 -8 1/2 5'-9 112 3'-7' 1'-8" L__: I t-- CI© I -t--' c� I CIE#4 t %/ `'-__-._--•_..__-- _ I u! CIE#12 #4 j r =�'`� CIR #11 CIE 11 - CIE 14 WIP 676 =2L .—.—.—.r. — \ ------- w�.—.— CIR 27 Y12 CIR #4 #2�_ NON-DEDICATED CIR#11 ! 15•-8 112' I � Z CIR #14 OUTLET BOX FOR l� \ 1 � � w BLDR. IN5IALLED /^\ /' C 2' w - N O CARBON-110NOXIDE t �, DEFECTOR / 1 \ ` \ / / I C CIR#27 I < `r ~ I < CIR #13 CIE#13 �\ /iLIR #11 CIE#11 I CIR#14 � •\. � � CIE 127 I m ` o � o � nc � BATH 2 II IR#4 / BONU5 ROOM I ^ \ w 'CIR 14 CIR#i4 CIE#13 CIR#14 �\ L�/ CIE # 4 ry 1 __ ______ __ =__, CIR #27 CIE #271 CIR #13`�\ /�/ /^ ,'/ \`� B E 0 R 0 0 M I# 1 I \� CIR#2�Y �'// \\`, L ——.- GIR 113 CIE#il — CIE #11' CIE#27Y -------------- N � / \ i -► III -N CIR #11 ~' N CIR #27 CIE 127 CIR#27 J CIE#27 BEDROOM # � — WALKI N Ili °` 5-to' 4-0• -- o = -----•—•----- BEDROOM # 3 III CLOSET :00 ®� N u CIE# w IY CIt #13 CIE 113 CIR#14 CIE#1 CIR #11 o CIR #27 S 0 0 N 0 FLOOR ELECTRICAL FLAN ---- ---- ---- -- ————————————————— -- o_ N KPH M. rq� Y q 0 O .a 1 0� -6'4-- SINGLE POLE SWITCH I® TELEPHONE JACK DUPLEX OUTLET CEILING FIXTURE ^\ /^, -Gc�a THREE WAY SWITCH I=* TELEVISION/CABLE 3Z�= SWITCHED OUTLET WALL MOUNT FIXTURE / \\\ WIRE FOR PADDLE Ft•N �'oA o�4252 �- FOUR WAY SWITCH WEATHER PROOF OUTLET PULL CHAIN FIXTURE / \ , 9�FESS�ONa� ' SERVICE PANEL GROUND FAULT OUTLET �__- FLUORESCENT FIXTURE v v --- �- DOOR JAMB SWITCH BREAKER PANEL 220V OUTLET RECESSED FIXTURE ``\ %'' ® SMOKE DETECTOR � \ ' ' WIRE FOR PADDLE FAN THIS DRAWING 15 THE PROPERTY Of. CIQ© CHIMES 0 EXHAUST FAN CABINET FLUORESENT T TRACK FIXTURE \`\ W/ LIGHT KIT AND SHOULD BE USED EXCLUSIVELY RECESSED EYE BALL MEXHAUST FAN MIGHT (� EXTERIOR LIGHT (WP) UNDER CABINET FIXTURE `�' BY HAVEN HOMES. INC. w SMOKE-CARBON MONOXIDE y � GANG BOX SWITCH Q THERMOSTAT sic DETECTOR COMBINATION �d'S HOLLWOOD LIGHT HAVEN HOMES, INC. RESPONSIBILITY LIMITED TO FACTORY BUILT PORTION ONLY. i i FJ4IDIA(,E BOLT ,� 1 b'4'x is, .019 m +�++ SIAAP-4-Dd NAILS CI TOP z Cf CEILING JDTS13-Ed © w NAILS Al EACH PLATE. SSION Z STRIP O N i CWTINUOUS 2'x 6' DME 21x 6' Q SL6-FASCIA TOP PLATE en N I ZA RIDGE VENT SHIPPED LOOSE 511E IN51All D BY THE HAVEN HONES SET CREW ROOF PANELS SHIPPED 100.E (2} 101 NAILS EACH SLOE 511E INSTALLED BY THE LUMEN _0_s_F. R H A N G PETAIL PER BAY FACTORY INSTALLED HOMES SET CREW !d15rAF I I t� 2 Z W O C� — ?fi FIDERRA5 SHINGLES OVER O U sp HINGLE UNDER1.019111.OVER �sJ °OJ 112' PLYWOOD ROOF SPEATPI"'G oz w �FrF�Js � cf� RIDGE VENT SHIPPED LOOSE SITE INSTALLED 2x4 KNEE WAIL SHIFPED 1005E 511E IN5iAILED 6 rPF la.l O BY iNE HAVEN HODS SET CREW ROOF PANELS 5HIPPED L005F INYEN HODS SET CKEW (2) tOd NAILS EACH SLOE 511E INSIALLED BY THE HAVEN N ch °C REFTt 10 EEtEYAT10N(91 Z p < se z PER BAY FACTORY INSTALLED HOLES 5E1 GREW (1 12 i t CH 51D � } FOt ROW PITCH 5 PER BAY 611E INSTAIIED MAINTAIN 2' CLEARANCE Lai z - K-m FIDERGIAS OR AIR FLOW w 4.p w CEILING IN5ULATION O nL o w _xI 2z6 CEILING JOIST.16'O.C. 5PF 02 O 4j w L.titfifkfiflAf to ALUMINUM DRIP EDGE 1Y arc O! 12'DRYWALL 112'DIA. BOLTS SITE INSTALLED CAULK TOP PLATE ALUMINUM FASCIA OVER U Q'I a a Y THE HAVEN HOMES SET CREW A CONTINUOUS 5UD-FASCIA DEPEN.DIN,fi ON UNIT WRATH DOUBLE 2x6 TOP 8'-0'MAXIMUM SPACING 112'DRYWALL i OVERHANG MAY BE FLIPIFED LATE 5PF#2 VENTED ALUMINUM SOFFIT OR�7 REFER TO FLOOR PLAN x n ?fis�o FHBINGLE UNOERLAYMERf OVER TITY MR 512EQOFNMItRO-LAN BEAMS I1r PLYWOOD ROOF SHEATHING R-19 FIBERGLA5 WALL 24 112' PLYWOOD SHEATHING INSULATION WITH 16'OEt1ESPfR STUD DGRADI J6, VAPOR BARRIER 2x4 KNEE W .,, AIL 5111FPE0 TYYEK HOUSEWRAP 1005E 511E INStnItED SPF 112'DIA. BO115 SITE INSTALLED iNYEN HLxES 5E1;.RELY �1 2xb BOTTOM 112' PLYWOOD OVER 518' SEE ELEVATION FOR TYPE ( 12 t o NAllS 51D LATE 5PF#2 PLYWOOD FLOOR SYSTEM Y THE HAVEN HOMES 5E1 CREW OF 51DIM BEING USED REFER TO ROOF �PITCH 5 PER BAY 511E IIISTALLED MAINTAIN 2' CLEARANCE 8'-0'MAXIMUM 5PACING CAULK BOTTOM PLATE ( )� R36 FIBERGLA5 OR AIR FLAY CEILING INSULATION 2xiO FLOOR JOIST$ 16' O.C. 5PF#2 N x I 5 # ALUMINUM DRIP EDGE x STRIP OF SHEATHING 5HIPPED O 112'CIA. BOBS SITE INSTALLED CAULK 16P PLATE ALUMINUM FASCIA OVER III IATE AROUNDLOOSE 511E INSTALLED BY 12"DRYWALL Y THE HAVEN HOMES SET CREW A CONTINUOUS 5U6-FASCIA ERIMETER 112'DRYWALL \�]Y/2'Dlh. BOBS 511E INSTALLED CAULK TOP PLATE THE BUIDER FOR iNlS AREA 1-- NDING ON UNIT WIDTH DOUBLE 2x6 TbP 8'-0'MAXIMCM 5PACING THE HAVEN HOMES SET CREW _x to HANG MAY BE FLIPPED LATE 5PF#2 112'DRYWALL VENTED ALUMINUM SOFFIT DOUBLE 2z6 i0P 8'-0'MAXIMUM/SPACING Q Ltl � LATE 5PF 12 112'DRYWALL m t12' PLYWOOD SHEATHING 112' PLYWOOD SHEATHING R-19 FIDERGLA5 WALL 2z3 MARRIAGE WAIL O 1 < INSULATION WITH x4 MARRIAGE WAIL c�_ 2x6 EXTERIOR STUD WAIL Tr- N z V 16'.O.C. 5PF STUD GRAD VAPOR BARRIER 16`O.C. STUD GRADE R-19 FIBERGLAS WAIL 5' < EW-- N < d w iYYEK HOUSE" 2z4 MARRIAGE WALL W 2x6 EXTERIOR STUD WAIL O < Oct V nc } IN5ULATION WITH m = 16, D.C.STUD GRAVE o 16'O.C. 5PF STUD GRAD 0 z o o 7) 0 1 VAPOR BARRIER ... I 2x6 BOTTOM 112'P1Y1�00 DYER 518' tit' DIA. BOLTS SITE INSTALLED "- SEE ELEVATION FOR TYPE z TYVEK HOUSEWRAP LATE 5PF 02 PLYWOOD FIObR SYSTEM Y THE HAVEN HONES SET CREW Of SIDING BEING 05ED 8'-0'MAXIMUM SPACING CAULK BOTTOM PLATE 10 2x6 BOTTOM 112' PLYWOOD OVER 518' tY21HEIHAYENA. IH01iE5TS T5E1NCREWIED SEE ELEVATION FOR TYPE OF SIDING BEING USED LATE 5PF#2 PLYWOOD FLOOR SYSTEM r 8-0'MAXIMUM.SPACING CAULK BOTTOM PLATE 2z10 FLOOR J015T5 16'O.C. 5PF 12 x 5rf 12 .iRIP OF 5NEAIHINMSHIMP C4 INSULATE A"VINO LOOSE 511E INSTAL2x10 F100R J01515 16'O.C. 5PF#2112 DIA. MIS ITE IN51ALl DERIMETEK 12'DRYWALL 5 E CAULK iOP PLATE THE BUIDER FOR TH R-19 FIOERGLAS INSULATION CENTER BEAN CONSISTS OF BOND TIMO R SUPPLIED N Y THE HAVEN HOMES SET CREW WITH VAPOR BARRIER SHIPPED AND 511E INSTALLED DOUBLE 2x6 TOP 8'-O'MAXIMUM SPACING (3) 2x10's GLUED AND NAllEO ( 6Y THE BUIlOER U aO o0 LATE 5PF 12 L005F SITE INSTALLED BY PER EACH MODULE FOR A TOTAL GRADE THE BUILDER OF (6) 2x10's WHEN MODULES 112'DRYWALL ARE BROUGHT TDGEIHEK 112'PLYWOOD SHEATHING �,�ti 5EE ANCHORAGE ( 10' CONCRETE W60NRY UNIT OR POURED ® � SCHEDULE ON A-3 COLUMN LAO BOLTED t0 i CONCRETE FOUNDATION WALL-TYPICAL a a, R=t9 FIBERGLAS WAIL `� CENTER BEAM BY THE BUILDER METAL PIPE COLUMN- SEE FOUNDAf ION PLAN INSULATION WITH 2x4 MARRIAGE WALL o, 2x6 EXTERIOR STUD WALL sN ( o VAPOR BARRIER 16' O.C.STUD ORADF 16.O.C. SPF STUD GRAD m z FOR QUANTITY AND SPACING PAR AND WATERPROOF ;q ' TYYEK HOU5EWRAP o� A FOUNDATION WALL BELOW GRADE F ' o-a � ME�m0.4 112'DIA. BOLTS SITE INSTALLED 5EE EIEYAfION FOR TYPE _' 4'CONCRETE SLAB OVER 4'2x6 BOTTOM 112' PLYWOOD OVER 518' o I CONTINUOUS CONCRETE 15a 14 LATE 5PF#2 PLYWOOD FLOOR SYSTEM Y THE HAVE MONIES SET CREW 11 OF SIDING BEING USED GRAVEL OR CRUSHED STONE i FOUNDATION WAIL F 8'-0'MAXIMUM SPACING CAULK 60110M PLATE O Et?J 2x10 FLOOR JOISTS 16' O.C. 5PF 12 A �- Y �•'. R-13 FI.bERGLhS INSULATION CENTER BEAN CDNSLSTS.QF BOND TI►OER SUPPLIED ���N M. Tql���p� co WITH VAPOR BARRIER SNIFFED (3)2%IO's GLUED AND NAILED AND SITE 116TALLED "� s � s 1005E 511E INSTALLED BY PER EACH MODULE FOR h TO1Al I BY THE BUILDER U GRADE * ^' THE BUILDER OF (6)2x1O's WHEN MODULES I ROOF DIAPHRAGM: ROOF RAFTER 10 2nd FLR s CEILING OLT51: gyp. .. PROVIDE 112' DIAM CARRIAGE iHRU DOLTS PER RAFTER 10 CEILING JOIST ARE MUM TOGETHER 15132' COX OR 05D (2410-EXP 1) PLY CLIPS 0 EDGES O SEE ANCHORAGE 10' CONCRETE MU50NRY UNIT OR POURED 8d NAILS 0 6' E.N. 12' F.N. OR s W SCHEDULE ON SHEET A-3 COLUMN LAO DOLT D TO CONCRETE FOUNDATION WALL-TYPICAL O 1116' x 2' x 16 Ga�51APLE5 0 4'E.H.,6'F.N. n F R s CEILING NG 0 5T TO VOL TO PLAT$: CENTER BEAM BY THE BUILDER ME1Al PIPE COLUMN- AIIUWABIE SHEAR=308 PIF i 231 PlF PROVIDE 1 il4 It 16 0.019'STRAP TOP OF EA. CEILING JOIST TO Fp 074252 �� O W I 6 VOL TOP PIATE OVER PLYWOOD 10 a am�i I EEE QUANI1TYOhNDLSPACING AN (4)8d NAI15 top OF CEILING JOIST, (3)8d NAILS 0 EA.PLATE 9aFE ' a PARGE AND WATERPROOF PROVIDE(3) 16d TOE NAILS 0 EA. ND OF C EE ILING1S1 i0 DBl TOP PLAT SS1U���� J0E '~ FLOOR DIAPHRAGM: o o FOUNDATION WALL BELOW GRADE j F>= 112' PLY 10 PLY, COX OR 050(2410-EXP 1) i&0 EDGES Bd NOV �oS�m TO, PLY: 7d 0 6'E.H., 12 F N a PERINETER ROOF RIM CONNECTION: w BOTTOM PLY: IDA 0 6' E.N., 12'F.N. ORN. PROVIDE 16d NAILS 0 0'-8 O.C.0 ROOF DIAPHRAM RIM CONNECTION TN I S I S NOT AN ACCURATE REPRESENTATION 4`CONCRETE SLAB OVER 4` I CONTINUOUS CONCRETE 7116' x 2' x 16 Ga STAPLES 0 4' E.N.,0'F.N. GRAVEL OR CRUSHED STONE I FOUNDATION WALL FOOTING ALLOWABLE 5HEAR=572 PLF 1 2W PLF 2nd FLR WALL STUD TO FIR RIM: OF FINAL PRODUCT. FRAMING MEMBERS ARE ® PROVIDE"51MP.ON' ISTA12 STRAP 0 60'O.C.WAIL STUD TO FIR Rlu SUBJECT TO CHANGE DUE TO UNFORESEEN LOADING REQUIREMENTS AND/OR THE f � PROM OEE112'dDIAM tHRU1U Kim CBO1t510 8'-0'O.C.ALONG PERIMETER 2nd FlR RIM IONPLACEMENTiADDITION OF A ROOF BOX UNIT THiS DRAWING IS THE PROPERTY OF. NOTE: BETA 11.5 ARE 51 M I LAR BETWEEN TH 15 5ECT I ON AND RIM BAND CONNECTING 2nd FLR RIM TO 16t M's CEILING RIM JOIST: AND SHOULD BE USED EXCLUSIVELY FKOVIVE 10 SUPPLIEDIANDNAILS0NSThD.C.,BTBUILDER BY HAVEN HOMES. INC. ALL OTHEK5 I NCLUDEP IN TH 15 5ET OF PRAWI NG5 RIM DAND CONNECTING 161;FLR RIM TO FOUNDATION SILL: HAVEN HOMES. INC. RESPONSIBILITY O it PROVIDE 164 NAILS 0 3' O.C., 10, � LIMITED TO FACTORY BUILT PORTION SUPPLIED AND 511E INSTALLED BY BUILDER ONLY. I i CAfp1IAGE BOLT Jo�S� t�.t LLI 1 1/4'x 16' .019 M71 z \ STRAP-4-80 NAILS OH UP OF In 11;JDBI 3-Dd z NAILS AT EACH PLATE. w I PLym N i mf mloll Z STNIP O O CONTINOS 2%6' DWE 2'z 6' uj SilB-TAsCIA TOP PUTE en N I m u OVERHANG DETAIL 1n sm w U 2xB HOOF RAFTERS L" O 16'O.C. SPF f2 p O U W . � 2x8 CEILING JOISTS L.t.1 chi O R-38 FIBS"CEILING VENTED ALIMINUN � t- 04 c U INSULATION W/VAPOR BARRIER SOFFIT BEYOND O n J } O z p < m z U of IRA m uj O m nc o xlix _.t RIDGE VENT SHIPPED LOOSE SITE INSTALLED o ek- o w d n — BY IRE HAVEN HOLE5 SET CREW DOIDLI 2x6 TLOP 1/2'DRYWALL 1/2'DRYWALL CAULK TOP PLATE SEE ELEVATION FOR TYPE O � 34 w (2) 10d NAILS EACH 510E PLATE SPF f2 OF SIDING BEING USED DC & O ta PER BAY FACTORY INSTALL[ U 1/2'DRYWALL 2x6 EXTERIOR STUD ROOF PAHE15.511IPPED 1005E R-19.FIBE1MAAS-WALL WALL 16' O.C. SITE INSTALLED BY THE HAVEN INSULATIOPN MI/VAPOR BARRIER o 4-1SPF STUD GRADE HOWE5 SET CREW 20 MARRIAGE WALL 16' O.C. SPF STUD f2 FIBA SHINGLES YLEOVER OVER P 9'EXTERIOR NGLE UNDERLA81 WOOD SHEATHING 112' PLYWOOD ROOF SHEATHING 2x6 BOTTKNU PLATE SPF 12 1/2'PLYWOOD OVER 5/8' INSULATE AA(NN PLYWOOD FLOOR SYSTEM 1/2' DIA. BOLTS SITE INSTALLED CAULK BOTTOM PLATE TYVEK HOUSEWRAP 12 2x6_CEIIING.J01515 ?fi BY TIE HAVEN HONES SET IJEN REFER TO EtEYA110N(5) 16'O.C. 5PF f2 ?p�F PERIMETER BID'O.C. MAXIMUM SPACING FOR ROOF(ITCH 5 R-ILIFNIO 11,15OULATION �FTF��s• &10 FLOOR JOIST 16' O.C. SPF f2 o� ►iAINTAIN 2'CLEARANCE 2X6 CEILING JOI T 16'O.C. SW f2 12'DRYWALL sp OR AIR FLOW �p AEfQt TO FLOOR PLAN =STRPINSTI;HEATHING SHIPPED LON N ------------„n,------------ 1/2'DaYrt'll. . . FOR QUANTITY AND CAULK TOP PATE t1J D BY THE BUILDER z0 III ALUMINUM DRIP EDGE 5/8 TYPE X L• . -------------Iw'----------------- FIREGUARD I Lu ALUMINUM FASCIA OVER 2x6 DOUDUt'u? _a U CAULK TOP PIA A tON11N0005 SUB FASCIA PLATE SPF 12 I < Lu DEPENDING OH UNIT WIDTH U 0) OVERHANG MAY BE FLIPPED VENTED ALUMINUM50FF11 26 EXTERIORI _ WALLS16'D.C. � O �I } 4 \--PLATE OUBLE 2x6 TOP R 19 FI6JAf WALL 4 {- Rl z tJ 5PF f2 INSULATION Wll VAPOR BARRIER �' I /g'TYPE'X'F7AEGUARO . z 112'DRYW ll 1/2'EXTERIOR < �" ram- t < < Q' 112'PLYWOOD SHEATHING 1/2'PLYWOOD OVER 5/8' I PLYWOOD SHEATHING O < to °C PLYWOOD FLOOR SYSTEM cn Z n W n aTEMPORARY 6- 1-19 FIBERGIA5 WAIL 4 I CONSISTINGCENTER BEAM S INSULATION WITH Q, 2x6 EXTERIOR STUD WALL 'k 2x6 BOTTOM POATE k GLUED AID NAILED PERIDUSEWNAP VAPOR BARRIER 16 O.C. 5PF 51UD GRAD f2 EACH MODULE FOR A TOTALZT TYVEK HOU5wAP OF (4) 24'sCAULK BO TOM PIATE- -------- ------ 2x6 B01TOM 112' PLYWOOD OVER 518' SEE ELEVATION FOR TYPE 2x10 FLOUR JOIST 16' O.C. SPF f2 u———— —�ASTSS104A. ————— ————LATE 5PF f2 PLYWOOD FLOOR SYSTEM OF 51DING BEING USED B'MIHODW H i9 Epgp;,jn� m SILLPLATESUPPLIEDANDChUIK BO11O11 PlA1E I p k/Y stU 2 T„f SITE INSTALLED BY BUILDER N v ell 2x10 FLOOR JOISTS 16'O.C. 5PF f2 io'CONCRETE MASONmI tfJIT (CMUI oA .. R-19 FIBER61.0 INSULATION BOND iiLIBEK SUPPLIED SCEDULE AON 3 U N E X C A V A T E D POUND ATE FOUNDATION WALL-TYP : WITH VAPOR BARRIER SHIPPED I AND 51TE INSTALLED MIA � BY THE BUILDER L1 GRADE $ CONTINUOUS CONCRETE FOINDATION N L005F 511E INSTALLED BY u� WALL FOOTING THE BUILDER I -� 0" CENTER BEAM CONSISTS OF SEE ANCHORAGE I (3)2xIO s GLUED AND NAILED 10-CONCRETE MASONRY UNIT OR POURED PER EACH MODULE FOR A TOTAL CONCRETE FOUNDATION WALL-TYPICAL 4'FRE?JL11 DRAIN SCHEDULE ON SHEET A-3 I OF (6) Zx10's WHEN MODULES v o u w ARE BROUGHT TOGETHER �"'=v' )d[TAL PIPf.COlU11N- I tJ m ' __ COIUAtt 1AG BT1liED i0 04 PURGE AND WATERPROOF ow ,� SEE FOUNDATION PLAN I CENTER BEAU BY THE BUILDER FOUNDATION WAIL BELOW GRADE FOR QUANTITY AND SPACING V 4' CONCRETE SLAB DYER 4` O OF N GRAVEL OR CRUSHED STONE I FOUNDATION WALL FOOTING �CP��PN M.OT T {� m ( , �. s 0�4252 sl%N�rr O a j tVOV-X 2006 0 TH 15 15 NOT AN ACCURATE KEPRE5ENTAT ION OF FINAL PRODUCT. FRAMING MEMBER5 ARE SUBJECT TO CHANGE DUE TO UNFORESEEN LOADING REQU I REMENT5 ANDiOR THE PLACEMENTIADDITION OF A ROOF BOX UNIT THIS DRAWING IS THE PROPERTY OF. AND SHOULD BE USED EXCLUSIVELY BY HAVEN HOMES. INC. ul HAVEN HOMES. INC. RESPONSIBILITY LIMITED TO FACTORY BUILT PORTION ONLY. ROOF FLASHING I I ROOF I ROOF I RppF I ROOF I ROOF FLASHINGFLASHING �FLASNINGFIASHIN6FLASHING O I 3-- _3, _3, _3, _3, _3, � If > r------�------j r------� r-----t--------r----------t I I FINISIEO w CEILING SYMBOLS IpG I I I I I I I I LINE HOT WATER LINES------- �- COLD WATER LINES--------- f If! I I( Ir Ii I i I 2FRE VENT. I 3. I 3' 1 1 3 1I 1I I I I VENT-—————————- I i-1/2 1 1 PLUGGED AND TAGGED SfA-N!/I TEE I SANI TEE Ij IiI II S I1j II III SAN IIIj III HASTE L INES I 2 SANI I TEE LEA SANI TEE 2 TJ 2 1-112' I f SECOND i. VANITYLLJ TRAP 2 TRAP /2 FLOOR 2. NATERCLOSET Z z 3. 3' I I 3 2' TRAP I I LINE 3. BIDET w O 1-1/2' TRAP 1-!/2' TRAP II L————— 3' SANI TEE 3' SANI TEE I �101 I TEE 1-1/2 TARP 1-1/2 I r——————— 4. TUB/SHOVER UNIT 1 I I I f-!/2'x3'x3' ��. . 2 1-1/2'x2'x2' I I I I 5. SHOVER w SANI TEE c zap x3 SANT TEE I 1-1/2' I 3' 1 I 6. GARDEN TUB �1-1/2 I SANIf TEE I I-f/2 7. WHIRLPOOL TUB �- {� f-f/2'x2'x2' V I I SANI TEE I I I B. DOUBLE BOWL SIN( Z 1 i 1 I I 9. SINGLE BOWL SINK » w O 2' TRAP I !0. LAUNDRY TUBAITILITY SINK 2'x2'xf-i/2' I I I I I ut O cc c SANI TEE I I 3' I 2 �I I If. DISHWASHER Q SANI.TEE i 13. WATER HEATE12. CLOTHES WASHER ac n<c 8 I I I I 1 14. PRESSURE AND TEMPERATURE RELIEF O tz o w 3' SANI EE I I I VALVE W/OVERFLOW DISCHARGE PIPE o o m 1f 2 2' TRAP I 12 i b 2 �2' FIRST 15. VACUUM RELIEF = .� m O • FLOOR 16. 3/4' DIAMETER OVERFLOW m CLEAN OUT 2' 2' TARP 3 1-i/2' LINE NOTES: —TO SANITARY SEVER f. ALL DOMESTIC SUPPLY LINES TO BE D E D R A M i/2' DIAMETER AND 3/4' DIAMETER J COPPER UNLESS LOCAL OR MUNICIPAL CORE REQUIRES OTHERWISE. FINISHED 2. ALL GRAIN WASTE AND VENTS ARE PVC --- CEILING PLASTIC UNLESS LOCAL OR MAUNICIPAL C- LINE CODE REQUIRES OTHERWISE. p 3. ALL HORIZONTAL PIPES TO.BE SUPPORTED AT INTERVALS NOT TO EXCEED 4'-0' 'U 4. SLOPE OF HORIZONTAL DRAIN WASTE AND z VENTS AT 114'PER FOOT MINIMUM. f f ! 5. PLUMBING BELOW FIRST FLOOR OF BUILD- V ING TO BE CONPLETED BY BUILDER. SECOND 6. CLOTHES WASHERS TO HAVE BACKFLOW O m Ch V 4 2 El 2 2 5 4 FLOOR PREVENTOR. iu ~ z Z - -——————. —.—.—.—. —.—.—.—.—.—.—..—.-- LIFE < ~ F•- M U ?- -- -- -- -- -- -- -- -- -- - - -- -- -- -- -- -- -- -- -- -- -- ---l o �- o 2'FUTURE VENT TO BASEMENT PLUGGED � Z 1/2' 3/4' AND TAGGED AS INDICATED ON DRAWING. B. ANTI-SCALD DEVICES AT SHOWERHfADS I � 9. HOT WATER HEATER SUPPLIED AND SITE IINSTALLED BY THE BUILDER j � I It 12 5 2 I FIRST .� FLOOR ——. —.-- —•---——_ ---— _—— -- -- 3/4' LINE -- --—�!/2`-/ 14 1-4 ; TO DOMESTIC �U SUPPLY C.a 16 13 BASEMENT FLOOR pF N`�V� .� LINE P�QNrA. rq�gp�p� to DOMESTIC 915E9 01A RAM 074252 f�® a 2006 THIS DRAWING iS THE PROPERTY OF. AND SHOULD BE USED EXCLUSIVELY O �: BY HAVEN HOMES. INC. uj ul HAVEN HOMES, INC. RESPONSIBILITY LIMITED TO FACTORY BUILT PORTION ONLY.