Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
37693-Z
�q�QsllEfpl Town of Southold Annex 12/23/2013 P.O.Box 1179 C 54375 Main Road o Southold,New York 11971 CERTIFICATE OF OCCUPANCY No: 36671 Date: 12/23/2013 THIS CERTIFIES that the building ADDITION/ALTERATION Location of Property: 375 Miriam Rd, Mattituck, SCTM#: 473889 Sec/Block/Lot: 99.4-30.1 Subdivision: Filed Map No. Lot No. conforms substantially to the Application for Building Permit heretofore filed in this officed dated 11/26/2012 pursuant to which Building Permit No. 37693 dated 12/17/2012 was issued, and conforms to all of the requirements of the applicable provisions of the law. The occupancy for which this certificate is issued is: ADDITIONS AND ALTERATIONS, INCLUDING COVERED FRONT PORCH AND DECK REPAIRS TO AN EXISTING ONE FAMILY DWELLING AS APPLIED FOR The certificate is issued to Pappas Peter 2012 Trust (OWNER) of the aforesaid building. SUFFOLK COUNTY DEPARTMENT OF HEALTH APPROVAL ELECTRICAL CERTIFICATE NO. 37693 06-26-2013 PLUMBERS CERTIFICATION DATED 12-02-2013 GENCO Autho ec ignat re J TOWN OF SOUTHOLD C®Gy BUILDING DEPARTMENT CIO TOWN CLERK'S OFFICE SOUTHOLD, NY Z T BUILDING PERMIT (THIS PERMIT MUST BE KEPT ON THE PREMISES WITH ONE SET OF APPROVED PLANS AND SPECIFICATIONS UNTIL FULL COMPLETION OF THE WORK AUTHORIZED) Permit#: 37693 Date: 12/17/2012 Permission is hereby granted to: Pappas Peter 2012 Trust \ 1 Fairway Ct Upper Brookville, NY 11771 To: construct additions & alterations to an existing single family & install hot tub to code At premises located at: 375 Miriam Rd, Mattituck SCTM # 473889 Sec/Block/Lot# 99.-1-30.1 Pursuant to application dated 11/26/2012 and approved by the Building Inspector. To expire on 6/18/2014. Fees: SINGLE FAMILY DWELLING-ADDITION OR ALTERATION $1,224.00 SWIMMING POOLS -ABOVE-GROUND WITH REQUIRED FENCING $250.00 CO -ADDITION TO DWELLING $50.00 CO - SWIMMING POOL $50.00 Total: $1,574.00 Building Inspector Form No.6 TOWN OF SOUTHOLD BUILDING DEPARTMENT TOWN HALL 765-.1802 APPLICATION FOR CERTIFICATE OF OCCUPANCY This application must be filled in by typewriter or ink and submitted to the Building Department with the following: A. For new building or new use: l. Final survey of property with accurate location of all buildings,property lines,streets,and unusual natural or topographic features. 2. Final Approval from Health Dept.of water supply and sewerage-disposal (S-9 form). 3. Approval ofelectrical installation from Board of Fire Underwriters. 4. 'Sworn statement from plumber certifying that the solder used in system contains less than 2/10 of 1% lead. 5. Commercial building, industrial building,multiple residences and similar buildings and installations,a certificate of Code Compliance from:architect or engineer responsible for the building. 6. Submit'Planning Board Approval-of completed site plan requirements. 8. For existing buildings(prior to April 9, 1957)'non-conforming uses,or buildings and "pre-existing"land uses: 1. Accurate survey of property showing all property lines,streets,building and unusual natural or topographic features. 2. A properly completed application and consent to inspect signed by the applicant. If a Certificate of Occupancy is denied,the Building Inspector shall state the reasons therefor in writing to the applicant. C. Fees . Certificate of Occupancy-New dwelling$50.00,Additions to dwelling$50.00, Alterations to dwelling$50.00, Swimming pool$50.00,Accessory building$50.00, Additions to accessory building$50.00, Businesses$50.00. 2. Certificate of Occupancy on Pre-existing Building- $100.00 3. Copy of Certificate of Occupancy-$.25 4. Updated Certificate of Occupancy- $50.00 .5. Temporary Certificate of.Occupancy-Residential $15.00,Commercial $15.00 Date. New Construction: Old or Pre-existing Building: (check one) Location of Property: (6Aji ( e ew House No. Street Hamlet Owner or Owners of Property: 7T- 6, Suffolk County Tax Map No I000,'Section : 'Block Lot' ` Subdivision :.Filed Map. Lot: Permit No. Date of Permit. Applicant: Health Dept.Approval: Underwriters Approval: Planning Board-Approval: Request for: Temporary Certificate- Final Certificate: (check one) Fee Submitted: $ R6y� S� Applicant Signatur S4FI'rU(Ire& Telephone(631) 765-1802 Town Hall Annex 54375 Main Road H z Fax(631) 765-9502 P.O. Box 1179 p Southold, NY 11971-0959 4,, �.a0� roger richertCa)town.southold.ny.us BUILDING DEPARTMENT TOWN OF SOUTHOLD CERTIFICATE OF ELECTRICIAL COMPLIANCE SITE LOCATION Issued To: John Pappas Address: 375 Miriam Rd City: Mattituck St: NY Zip: 11952 Building Permit#: 37693 Section: 99 Block: 1 Lot: 30.1 WAS EXAMINED AND FOUND TO BE IN COMPLIANCE WITH THE NATIONAL ELECTRIC CODE Contractor: DBA: STS Electric License No: 41857-me SITE DETAILS Office Use Only Residential X Indoor X Basement Service Only Commerical Outdoor X 1st Floor X Pool New Renovation X 2nd Floor X Hot Tub Addition Survey Attic Garage INVENTORY Service 1 ph Heat Duplec Recpt 57 Ceiling Fixtures 5 HID Fixtures Service 3 ph Hot Water GFCI Recpt 9 Wall Fixtures 18 Smoke Detectors 9 Main Panel A/C Condenser Single Recpt Recessed Fixtures 52 CO Detectors 3 Sub Panel A/C Blower Range Recpt Fluorescent Fixture Pumps Transformer Appliances 2-dw Dryer Recpt 20a Emergency Fixtures Time Clocks Disconnect Switches 48 Twist Lock Exit Fixtures TVSS Other Equipment: 5-exhaust fans, 1-hydro massage tub Notes: Inspector Signature: ti - Date: June 26 2013 Electrical Certificate.xls E C L'1 E D EC 10 2013 BLDG. DEPT. TONIPI OF SOUTHOLD CERTIFICATION Date: Building Permit No. Owner: cwn O p\(1 (Please print). Plumber: BUJ C,0 (Please print) D. v n k 5�p q TT--- ,ms-F ,)-B 0 ram-, YO 10 C I certify that the solder used in the water supply system contains less than 2/10 of 1% lead. C ' (Plumbers na Sworn to before me this day of �, 20� nA iHIMM Ffttar, inc - State of New York. 01TH6088565 ed in Suffolk County _ion Expires Notary Public, L �County OP SOpryo� 3-7 N � TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION -- m_ [ ] FOUNDATION 1ST [ ] ROUGH PLBG. [ IF NDATION 2ND [ ] INSULATION [V FRAMING/STRAPPING [ ] FINAL - [ ] FIREPLACE A CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL UGH) [ ] ELECTRICAL (FINAL) REMARKS: a DATE —INSPECTOR . . pF SOpjyo6 TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECT ON . [ ] FOUNDATION 1ST [ OU PLBG. [ ] FO NDATION 2ND [ INSULATION [ FRAMING/STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIR AFETY INSPECTION [ .] FIRE RESISTANT CONSTRUCTION [ FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: DATE 03 INSPECTORS ~ pf SO(/jyolo # • �# �cou TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION- I FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] INSULATION [ ] FRAMING /STRAPPING [ ] FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) <PZELECTRICAL (FINAL) REMARKS: DATE t INSPECTORW?� f . �o COMM TOWN.OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION. [ ] FOUNDATION 1ST [ ] ROUGH PLEIG. [ ] FOUNDATION 2ND [ ] IN ATION [ ] FRAMING /STRAPPING [ ` FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: rT� � b3 '3 � t DATE ' INSPECTOR F SO ��0 Ulyp ,`0 6 p�y�OUMV N� TOWN OF SOUTHOLD BUILDING DEPT. 765-1802 INSPECTION [ ] FOUNDATION 1ST [ ] ROUG EIG. [ ] FOUNDATION 2ND [ ] I LATION [ ] FRAMING /STRAPPING [ FINAL [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: C r✓ -[ �- r�-S 'r- q DATE /-),/ 3 INSPECTOR 0 Ul • ao TOWN OF SLD ;_-11-0 DING DEPT. 180 INSIP N [ ] FOUNDATION 1ST [ ] ROUGH PLBG [ ] FOUNDATION 2ND [ ] INS ION [ ] FRAMING /STRAPPING [ INAL ra 6,&_v_eL� [ ] FIREPLACE & CHIMNEY [ ] FIRE SAFETY INSPECTION [ ] FIRE RESISTANT CONSTRUCTION [ ] FIRE RESISTANT PENETRATION [ ] ELECTRICAL (ROUGH) [ ] ELECTRICAL (FINAL) REMARKS: A A n r — 1► !„ ► DATE l INSPECTOR u HITECT MARK SCHWARTZ &ASSOCIATES 28495 Main Road•PO Box 933•Cutchogue, NY 11935 631.734.4185 1 www.mksarchitcct.com August 22,2013 Southold Town Building Department P.O. Box 1179 Main Road AUG 2 3 0 Southold,New York 11971 BLDG.DEPT. Re: Additions and Alterations to: TOWN OF SOUTHOLD Pappas House 375 Miriam Road Mattituck,New York Permit#37693 (SCTM#1000-99-01-30.1) To Whom This May Concern: I have been to the site during construction and reviewed the plumbing, insulation, framing and strapping. I hereby certify, to the best of my knowledge, the pressure test and plumbing, insulation, the basement framing, columns & footings and the overall strapping work has been completed as per plans and meets or exceeds NYS code requirements. Please call this office if you have any questions or require additional information. Very truly yours,,.. FF -T Mark Schwartz' AfA klembor American Institute of Architecture y — a WAN' y Ji 'iMINN �. i►tom/ � / / � '� r, ' /, 1 •STATE CODE �. v • r I I TOWN OF SOUTHOLD BUILDING PERMIT APPLICATION CHECKLIST BUILDING DEPARTMENT Do you have or need the following,before applying? TOWN HALL Board of Health SOUTHOLD, NY 119,71, 4 sets of Building Plans TEL: (631) 765-1802 Planning Board approval FAX: (631) 765-9502 Survey SoutholdTown.NorthFork.net PERMIT NO. 3.'76 fJ Check Septic Form f N.Y.S.D.E.C. Trustees D C.O.Application Flood Permit Examined 2- ! ,20� Single&Separate Storm-Water Assessment Form Contact: Approved /7 20 BLDG. DEPT. Mail to: A e 1 w � / _— _ TOUJN OF SOUTHOLD Disapproved a/c Phone:• 7.J Y' 4_1 Op ►� Expiration 20_/_� Building Inspector APPLICATION FOR BUILDING PERMIT Date 'Z , 20 INSTRUCTIONS a. This application MUST be completely filled in by typewriter or in ink and submitted to the Building Inspector with 4 sets of plans, accurate plot plan to scale. Fee according to schedule. b. Plot plan showing location of lot and of buildings on premises, relationship to adjoining premises or public streets or areas, and waterways. c. The work covered by this application may not be commenced before issuance of Building Permit. d. Upon approval of this application, the Building Inspector will issue a Building Permit to the applicant. Such a permit shall be kept on the premises available for inspection throughout the work. e.No building shall be occupied or used in whole or in part for any purpose what so ever until the Building Inspector issues a Certificate of Occupancy. f. Every building permit shall expire if the work authorized has not commenced within 12 months after the date of issuance or has not been completed within 18 months from such date. If ho zoning amendments or other regulations affecting the property have been enacted in the interim, the Building Inspector may,authorize,in.writing,the'extension of the permit for an addition six months.Thereafter, a new permit shall be required. ` APPLICATION IS HEREBY MADE to the Building Department for the issuance of a Building Permit pursuant to the Building Zone Ordinance of the Town of Southold, Suffolk County,New York, and other applicable Laws, Ordinances or Regulations, for the construction of buildings, additions, or alterations or for removal or demolition as herein described. The le applicant agrees to comply with all applicab ;laws, ordinances, building code, housing code, and regulations, and to admit authorized inspectors on premises and in building for necessary inspections. (Signature of applicant or name,if a corporation) (Mailing address of applicant) State whether applicant is owner, lessee, a ent, architec engineer, general contractor, electrician,plumber or builder Name of owner of premises /� '�tn% d57 (As on the tax roll or latest deed) , If applicant is a corporation, signature of duly authorized officer (Name and title of corporate officer) Builders License No. Plumbers License No. Electricians License No. Other Trade's License No. 1. Location of land on which proposed work will be done: -375- O/-k House Number Street mle County Tax Map No. 1000 Section 99 Block 0 t Lot ,3�. Subdivision Filed Map No. Lot 2. State existing use and occupancy of premi es� intended use and occupancy ofpr proposed a. Existing use and occupancy �/ G � x; 1'/L! b. Intended use and occupancy /q ,� 3. Xture of work (check which applicable): New Building - Addition DOAM 61 rAlteration� "Repair DEG KS Removal Demolition Other Work /VEw t+o r T-Ct� (Description) 4. Estimated Cost Fee r7 (To be paid on filing this application) 5. If dwelling, number of dwelling units umber o 'dwelling units on each floor If garage, number of cars 6. If business, commercial or mixed occupancy, specify nature and extent of each type of use. s ��_j 7. Dimensions of existing structul'es, if any: Front Rear Depth Height Number of Stories Dimensions of same structure with alterations or additions: Front Rear Depth Height Number of Stories 8. Dimensions of entire new construction: Front Rear Depth Height Number of Stories C,� v 9. Size of lot: Front �' S Rear Depth 10. Date of Purchase Name of Former Owner 11. Zone or use district in which premises are situated O 12. Does proposed construction violate any zoning law, ordinance or regulation? YES NO/-,< 13. Will lot be re-graded? YES NOZWill excess fill be removed from premises? YES NO 14.Names of Owner of premises •1a 4iou r.1410 If Address Phone No. 7 Name of Architect /11 `YLrZ Address Phone No Name of Contractor (2H/f12(X-f' ,t36/Z,O b� Address Phone No. 2- S' 94 2 5- 15 a. Is this property within 100 feet of a tidal wetland or a freshwater wetland? *YES NO * IF YES, SOUTHOLD TOWN TRUSTEES & D.E.C. PERMITS MAY BE REQUIRED. b. Is this property within 300 feet of a tidal wetland? * YES NO_X_ * IF YES, D.E.C. PERMITS MAY BE REQUIRED. 16. Provide survey, to scale, with accurate foundation plan and distances to property lines. 17. If elevation at any point on property is at 10 feet or below, must provide topographical data on survey. 18. Are there any covenants and restrictions with respect to this property? * YES NOA_ IF YES, PROVIDE A COPY. CONNIE D. BUNCH STATE OF NEW YORK) Notary Public,State of NexN York SS: No.01 BU6185050 COUNTY OF Cel (qualified in Suffolk County �J nK Commission Expires April 14,2� /4e,c S'o-1 L""47e! r- being duly sworn, deposes and says that(s)he is the applicant (Name of individual signing contract) above named, (S)He is the (Contractor, gen orpora e Officer, etc.) of said owner or owners, and is duly authorized to perform or have performed the said work and to make and file this application; that all statements contained in this application are true to the best of his knowledge and belief; and that the work will be performed in the manner set forth in the application filed therewith. Sworn to before me this `�►1 day of byel;r"LO---, 20 1 Notary Public Signature of Applicant "ID Town of Southold - Chapter 236 - Stormwater Management SWPPP - Storm Water Pollution Prevention Plan Assessment Form GENERAL INFORMATION: (All Requested Information is Required for a Complete Application) APPLICANT NAME: Owner-Agent-Consultant-Contractor or Other (Circle one) Property OWNER:(If Different than Appl'Icant) S w,4/e -41CC*1 J OrHA) fl+ Ol �p Address: ,7.7 C v �i v� Address.' vr /V//el/q/et Telephone#: 7 3 p r Fax r .,let- Telephone A:d r 74 4-O pO j p Fax ih E-Maih a P-C 44 O f4-,7 4•,e .,le E-Mad:Jja fa vuS#0 o-4 Tyr`° Yq H-p o. Gavel Property Address: Brief Description of Conshuction Activity,Proposed Structural BM N Soil S.r-TAL#: 1000 2� �_ pJ Stabalization BMPs,Project Scope and/or Sequence of Construction Activity INfbkt Section Sloth Lot (PrordeAddVortarPa9esast)ealed) Name ofContraetorandlorContactPersonResponsibleforImplementationofSWPPP: �Qf QQ J06"re'-ti � �--------- Address: -------- Af .� p 7G1Z.4iLi�v--- #: � fT� G Telephone r Fa� E-Mail: ebond 2 o -----..fYbj,� __ --- Name of Persons Responsible for Installation 3 MtIntenance of Erosion Control Praetix: ��d Cff'1 etu-rr Qaoof _ _-w�---------------------------- Address: -------------------------------------------- Telephone#: Fax#: ---------------------------------------------- E-Mail Total Area ofAq Total Area of Land Clearing ----------------------------- Project Parcels: 000�/ andlor Ground Disturbance: 0. 0 -------------------------------------------- (F./Aces) {SF.I A—) Project Duration: Ap a Start End ________________________:__.._..____________ (Anticipated) // Z D j 1 Dale: Z Z Date: O �6 I v ---------------- ------------------------- Will this Project Disturbe five(5)or More Acres'at O ® ^ Any One Time During the Proposed Development? Yes No ------------------------ If YES:Please Answer the Followingi ------------------------------------------------ a. Does the Applicant have a Qualified Inspector On Staff To Conduct the ReAuired Inspections? Yes No b. Does the SWPPP Indicate HOW Frequently-the Site ,= F7"1 List the NAMES or description of all Potentially Impacted Waterbod)es andlor Wellands: Inspections will Occur and for What Period of Time? Yes No �,- c. Does-the SWPPP Adequately Identify All Temporary Q U -and/or Permanent Soil Stabalization Measures 7 - Yes No d. Does the SWPPP Adequately Identify a Complete Q [.71 Project Phasing Plan? Yes No Status of Impacted Walerbody:(eg.'TMDL,303(d)Listed,Impaired_) e. Does the SWPPP Indicate Additional Site Specific Q F__i Practices that Will be Utilized to Protect Water Quality? Yes No U Has the Applicant Submitted a Completed DEC Notice Type of impacted Waterbody:(eq.Lake,creek,say,Pond,Sound,Freshwater Wet)and-) Of Intent and SWPPP Acceptance Form for Review = [� by the Town of Southold? Yes No SPATE OF NEW YORK, COUNTY OF..rU. FdL� .....:.......SS Notat^i Public,State of Nse York No.0113U6985050 �1 1batI, /"...:��. .....sPCk-&Gf.�t/��tr-bein dul sworn de ses and sa OuliF°ed isi Suffolk bountyo'ftnd d�alskocuent) � g Y Po .a'stl�?�4���s?����IIP�J4�l�oE�erm,t, A nd that he/she is the .......................................... �:'. .:.1.. .... ..... (Owner,Contractor, Corpora Otbcer,et¢) ••• Owner and/or representative of the Owner or Owners,and is duly authorized to perform or have performed the said work and to make and file this application;that all statements contained in this application are true to the best of his knowledge and belief;and that the work will be performed in the manner set forth in the application filed herewith. Sworn to be�forpee me this; I^ , -----•. `�,------ day of.. v... _....LL/ .20_ 1. Notary Public .! P ----•-----•--... AW ) SWPPP Assessment FORM: 03-12 f Town Hall Annex 4 4 Telephone(631)765-1802 54375 Main Road �r (631)70g5QQ2 P.O.Box 1179 G • O roger richert(tU_#Own.souttlo(d.nY.us 1 Southold,NY 11971-0959 Wa DING DEPART NEW EW TOWN OF SOUTHOLD APPLICATION FOR ELECTRICAL INSPECTION REQUESTED BY: ,- Date: 2- 2-1 1 Company Name: s J �L Name: ' License No.: /-//o ��- Address: - bu fL 10/A4C Phone No.: . JOBSITE INFORMATION: (*Indicates required information) *Name: , i2Io o �Tor�S *Address: SMitzi &M L14 2 �h c N o /iq-5 L ' *Cross Street: `Phone No.. (lo?, 1 - 356 -q(p 9 A Permit No.. Tax Map District: 1000 Section:7 Block:�` Lot: 3 o, *BRIEF DESCRIPTION OF WORK(Please Print Clearly) yZoo I o �12 1 (Please Circle All That Apply) Is job ready for inspection: �Y� NO. C-Rough�In Final *Do-you need a Temp Certificate: YES NO Temp Information(Ifs needed) *Service Size: 1 Phase Whase 100 150 200 300 350 400 Other *New Service: Re-connect Underground Number of Meters Change of Service Overhead Additional Information: PAYMENT DUE WITH APPLICATION q-, 9 .82-Request for inspection Form I to, , N OF SOUTHOLD PROPERTY RECORD CARD OWNER STREET VILLAGE DISTRICT SUB. LOT FORMER OWNER N E ACREAGE 41 1 S W TYPE OF BUILDING RES. 3l SEAS. VL. FARM COMM. I IND. I CB. I MISC. I Est. Mkt. Value LAND IMP. TOTAL DATE REMARKS .t i } l v.`,. AGE BUILDING CONDITION NEW NORMAL BELOW • ABOVE FRONTAGE ON-WATER. Farm Acre Value Per Acre Value FRONTAGE ON ROAD Ar Tillable 1 BULKHEAD Tillable 2 4DeC-K; r CJ C fit/ 6 Tillable. 3 c p� Ca Woodland Swampland Brushland House Plot Total `�, OWN OF SOUTHOLD ' PROPERTY . RECORD CARD"' u /occ t _ 30. 1 OWNER STREET VILLAGE DISTRICT SUB. LOT 3 . FORMER OWN R N E ACREAGE Q3C7 S W TYPE OF BUILDING ;:ES. �f�� SEAS. VL. FARM COMM. I IND. I CB. I MISC. I Est. Mkt. Value 'LAND IMP. TOTAL DATE REMARKS �► er 5 i3�" r f 3 Z 6Z "�dlof 4,��. TO Cs++ 7 / /'1"� •a r �I C`?S;,S'!p '.fit Jl �JI�� (' ,rJ,>JS G! CS E Pie U DING ONDLT ON NEW ` RMAL BELOW �.� BOVE _ FRONTAGE ON WATER Farm Acre Value Per Acre Value FRONTAGE ON ROAD Tillable 1 BULKHEAD Tillable 2 -DOCK Tillable, 3 Woodland Swampland Brushland House Plot - Total .44 14 Akio �.. .p BQ. >< Foundation Both • 48 3,7�5 Basement Fl i R -• • • jj Interior • ,tension • • Heat Porch Roof Type PorchRoorris IstFloor -eezew• Patio ■ ••• • FloorC ra- irage Driveway Dormer { _ p. ' 1 V. MAP, OF ' \'\y ✓ i . rr# € .. mot/ Munrtuak° N � PTA IN KI DD ESTATES MATT.ITUGK INLET r, �� ice ' i y t TOWN OF:SOUTHOLR. I SUFFOLK.Go.,.N.Y.' rSFF .' Scale in feel'- / j?`. �aa •' wo voo, /65 6} o GA PTAIN •.K IDD STATE ES F t t Etr.� v ���/✓..• 556 t �' 6R'. 9hWYnl'����y�� `✓ .�}� KEY M A P�7 JPN 1g,o�M 6 ���� e�• AB �,r�o \y`rod;; �Ze25Z oo y9 .,�4 �,f.a (•}� a ®7:a pt+r>s r-t ii �' `� 282 s :1"I a t•t i t u � rRes a r cm m�mtu ca mn O/i �� e V • K P C I ae• /%��' b -et go,2 a i:. , k 19 f ��.z.r �/_ 1 ��/��/��en b �� 5, � ". •y a,tt )2 � Nee° r{3 ip.1• 77 7 1 e_ 5.. ✓V' ,�t1�c,h;`�ry i.�`_ r"y ,,•�/ '` t ` i Q?v \° Y ,1'{l. Q - i- - ly t 5 y qq6 '.t '� 5 � � 6c m'•S,,,,. -.. 6�\\\R v. .� ��'rl 'tS <m 98 7--.yu•.• G M� �E ra• , '?,�a. '-"t �Z r. @ i ip)t I n � \ ''y• o e1 V'E.. w' o � _ ® - ¢ �i t' g�i -ta y{ �:� � .j J + th I �e o .i� , � �_ -. - •I t a t r 7.:. X f y a- a s° Y�. 5 ':'rr '` fi -t "`R"`re.:F �81'J 'b2 63 .pq. e •} rn ...J h tl a Ian I y 9 - 85 a6 b'T N as ao e e '�}�•�t e �.f0©�IOA 106� •"-'.'{-L�{ +r , I v I lµ9 r 124; 125 12e l2T 128. a t�34 F-L°., .P r ' l20 sL { e. N .JCS- 92 �g9 IpgG ,°°rRpa „y.3anl fte2 i ya.7%� 0 133, 132 131 '13q 129a m fsq 136k13'T. "�:a. v �.�Iqq Ilb'II cR�ntswrpJk¢�t` , r J:121 Av - �� s 153 'ISZ IS o 138 139 1 :q'a t �"' Q a 119'..+I,t I8 I-¢e a .. 'P.•t l�'�, { 4 313 fby rr. '4t� 1'2 o i- .;4 A I`ii 1'7 ZG O 14`� f4. ,p 4f Id2 f 3 A- !]R...I v :IIS I hereby eerl'I#y.thaf thrs rnA�iwds r. 2q$o-r t r NORM O J 1 i$ Ta,:!" 181 �82 O 1¢6o IdS Y 55 156 IS .�." ? JdiiuA 31!947<'Apd ihdl caryaYe 8 g �- -g, �+� t. v 1.8., s r rnonumGrrfshavebecdsetb ta5 '�,..� rr a., s l'f't IT4.['^O 1$O 1f3�.- !g-�" r ° °• /6 16 ,. C- Mery n'`S,I�S y it `" �,� A t + k7 rm'F N p r • d'L I 18 R.1 102Y L enied 5 e r. Pzo Iz6 Izs'g o I is s .18 8 f o Q� ,?a>�a�,j. r Mt "rl� ''"+�°srij6 ' ` t R U T�1=1 NOW dIP3}�r L :. r 't ..�. r a 3 1 19'1 198 ® 200 zbt —"wan 199 S 1�rJ S !; Radlue bf�Curl}a rdad cornersr cite �j': . yy,\ othervJrst shown+ Is Aso feet p r r 1`"j N"ry` lE�7.}� r c 4 rG r '�EEFH.Y. e3@bw�d•I.nh�9d�b;l[i <y� 7g�a .3 'i d 8 o!Hap : wA r+ T6SY Sp! OfLSLF4h 7 'AAQ,ri'?$..yt5 R!�8���8 .At 3;:�P�ie+j,'.$ i�7 I rlr tv t . tr '' 's^rt','5�{,ll `F} nob;V'4eam4 .4. IBM! R hq a i+a• a''r4 �,=F .� I I—��M1�{p��t�, .` t :xa_Nny WO)�d���,�Fj} r-v A !",I)�c ..y. I o >t.`t,� ry ?y�P '�it�R.2i +t q s" Tr �� � nL'e� s....?2"q� e7+•r r•cy'7`.� iy y.. .i`. mot' .`"`2,`. x�b rri"✓< �1�ysa, d24`vyrs �u i.}z\ a6ivr rth• j � SS.'�wrsi .per F''iw" put ' P� "r1�.t , fz"r�f�.M. 'k 1 1 .�—�n +A�,o v'a �r {a. iq e r vYSs.mot 4� is rl'• s k. �T£:M�'YS v!z �.} �y'wX,#r e� g •rc.r t i j 7� + '' "�, a -. �, "?: t t t^ Y.r o o- L.;S2 ,i r <,7oS•-fA 1Y lAi18"' d+drY S'd "`"'t° ';X`vr'yr ,"�'�.A r a�• '� r-i4 � agr: d ��•` ad' 3 s pj-1Y fr a}' 'gar 3�".•?�3.'c*d Na 5 V .w 3'`R.a �+... _d A '- I i`,'•'�r`n sf ,r7a�4ianE;Yt'J :n s1P,lii u` 1.-�' r $ '.:,j ,4 tr17,.6u el e. y:.ssi ay�4 � } �'f3-'},p���1� ryy i f"' i`4 w .t flg}it a'rn1t 'f �.�� CS '.• e o-4-ty M S�nd�.)A �~ 2,n k``�; r� 5,X t � r„n°� � � ky:.,tF�i 4 r " "a'� *� S'�`y+}d�'"kN'f� ... 1,1 ..��V9. a r i.Elsspodl d G'e $�"i'r a .. w 'a• t�,c ,.':•S"+a�1i,�5'� J '�.'#'� 4+�+'���``,, k"rct ;a;.v I t F xSrz" y y r,F `3 t •i..a ,,"* .r tit F�r.' }.,- tV sty .el°(ca ; { $��}., t k x rl t'�-3: + w4.. £.'fit � y', .vv�� ,,�� 67 r,•r 4 r�.;'..xt _ •'(�'r �'e r. ytU'j�.t�e YS' �, ,a, °4 1 +k + Q�I4{, 4'''SI' ti�' a ;u '�' .fi�i 4.°kip rpr a, e'd F5tr..,' , ..1. "� t FP vgK't � y - 4,.1p ,� �A �•1, � 'i !P�� 4 -�.` ed•1`v f� � +sj 'w.�•.�'o���RF�ghe1'gts r ,4!� '`�'"-�,� A`o { a� �2 } k * �����• T-I 3 r • 1 Lot /6 Lot /7 '8/t AUG 17 PH 3 07. N.52000'E. /00.00 FL:3AI6 I E1.j22. • 1 6 I 1 V~I r—? r. O EL-44.9 L'4/\ .t LG WOOD iR DFCK I N Q I OWEL 28.3' Ci? s P�oPo5ED .I t $TORY lFRAMQ ,s 1' ra-I H � O 1 k • OUFE {� CARA�Jtti �n 1 S j tv C 1 Z moSEe 171f!/Zi='!�l?s WI -i°i ra.l• a a° AD •I ro ., m � o /O,9 'c b ~ !t Q _ .S p in ..( Kr.o' �• Q� Ems•. [a � ,, yl t�r I \ ILI ii In Im I � J I 3 L`- a. >. A CD 40 to (p v O d! Z f) rf\- 0 oOt 3 lip. is _*ra.�..,..:-._:ta•:✓:�_ �a,.:..�. •+ EL=300 ' it"of.i 5.52*00`W 25T.48 S.52°00"W, /00. 0" �y EL�29.P MI IA/1/I EL,24 B � .�`r�� • v f SURVEY-FOR " SUFFOLK ' COUNTY C,":'r.;.,,. :'i <.:r F'•FXTH SERVIC!'s PETER PAPPAS WANDREA PAPPAS LOTS. 30 a 31, "CAPTAIN KIDD ESTATES" AUG, 14, 1984 FOR !•f'I'Z0',/'.'.. C;: 1'!; . 1. , , „':LY AT MAT,T'ITUCK DATE: MAR. 10, 1983 TOWN OF SOUTHgLD SCALE: I 30' DATE SUFFbLK COUNTY', NEW +YORK NO. . 83- 138 M UNAL71HOIl1ZE0 ALTERATION OR ADDITION TO THIS /%PPROVED. �� - _. SURV Y;IS VIOLATION 0� SECTION '7209 OF THE -- •-• ---^— ---- NEW ,K STATE EOUCATIQH LAMA t K CtlP1ES O! THIS SURVErI•NOT BEARW6 THE LAND Lf NEi; F SURV,EY�1R'$$ INKED SEAL R EMBOSSED SEAL SHALL NOT fit lCON`SIDERED TO B A VALID TRUE COPY KOU�RA{1TE&S INDICATED' EREON SHALL RUN ONLY TO HEALTH DEPARTMENT-DATA FOR APPROVAL TO CONSTRUCT THE f?EI(. N FOR 1(IHO)A T�IIE SURVEYI.IS PREPARED -lk E� -AND p l$ kHALF TO TE�E TITLE CO'�MPANY,GOVERN- K NEAREST WA' rkAIN ML! *30URCE OF WATER: PRIMATE_PUBLIC✓ MENI`AL•'AG#NCY AND•LENOIN0 INSTIYUTION LISTED M SUFFCO, TA1(MAw AXlSF .Q9_SECTION�2-BLOCK-.L-LOT 29A30 HERE . {;AN4 TO.-,THE ASS,Itl3. EES OF 1'HE LENOING M TH[RE ARE:NO DWE LIMB! WITHIN 100 FEET Of THIS-PROPERTY UT1 Nr GUARANI ES ARE HOT'TRANSFERABLE ui TO AODI�IO►IAL INSTIT�TI S OR SUBSEQUENT ^' r OTHER THAN THOSE SOWN HEREON. c K THE WATER JUPPLY RND SEWAGE DISPOSAL SYSTEM FOR THIS RESIDENCE OWNER$, WILL CONFORM'• TO THt STANOAJtO! OF THE SUFFOLK COUNTY DEPARTMENT *OIS'TANCE SHOWN HER O.N FROM PROPERTY LINES TU .� i •. �,d OF HEALTH SERVICES. _ TO ExISTINf( STAUCTURE�' ARE FOh;A SPECIFIC is•��� I _,c•"r/ �: ' PURPOSE AND ARE NOT tO BE USED TO ESTABLISH APwLICAMT& PROPERLY ONES OR FOR�TME ERECTION OF FENCES �,� ADDRESS4OMSTRAh ER >W' TEL. Y UNG a YOUNG RRI ERHEAD, NEW YORKE ScSTAKE UBDIIV S ONNMAP FILED IN THE OFFICE OF THE CLERK OFSUFFOLK COUNTY ALDEN W.YOUNG,PROFESSIONAL ENGINEER ON JAN,19,1940 AS FILE Na 1672 AND .AND'SURVEYOR N.Y.S.LICENSE NO.12845 ,x HOw D W.YOUNG, LAND SURVEYOR N THE LOCATI011 bF WELL!),SEPTIC TANK(ST)0 CESSPOOLS(CP)SHOWN HEREON N;Y.SQ LICENSE N0.45893 BS ARE FROM FIELD OERMITIONS AND OR DATA OBTAINED FROM OTHERS 1 BRANDIS & SONS, INC. 1618 pp fZREScheck Software Version 4.4.4 Compliance Certificate 'p E C E � W E AUG 2 6 2013 Project Title: BLDG. DEPT. Energy Code: 2010 New York Energy Conservation TOWN OF SOUTHOLD Location: Suffolk County,New York Construction Type: Single Family Project Type: New Construction Conditioned Floor Area: 0 ft2 Glazing Area Percentage: 16% Heating Degree Days: 5750 Climate Zone: 4 Permit Date: Construction Site: Owner/Agent: Designer/Contractor: Pappas House Mark Schwartz,Architect 375 Miriam Road P.O.Box 933 New York,NY Cutchogue,NY 11935 631-734-4185 mksarchitect@optonline.net Compliance: Passes using UA t Compliance: 14.3%Better Than Code Maximum UA: 56 Your UA:48 The%Better or Worse Than Code Index reflects how close to compliance the house Is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Cavity Cont. Glazing Assembly Area or or Door UA Perimeter U-Factor Wall 1:Wood Frame,16"o.c. 426 19.0 0.0 21 Window 1:Wood Frame:Double Pane with Low-E 69 0.300 21 SHGC:0.00 Ceiling 1:Flat Ceiling or Scissor Truss 21 30.0 0.0 1 Ceiling 2:Cathedral Ceiling 135 30.0 0.0 5 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed et the 2010 N York Energy Conservation Construction Code requirements in REScheck Von 4.4.4 and to comply with the mandatory uir lists REScheck Inspection Checklist. Name- tie Signatures :yyr�; r k'laj Date F dfr�C'r6Y at. �S es Syr 5. �! /^4rz "y yy Project Title: Report 08/23/13 Data filename: C:\Users\Drafting Station\Documents\REScheck\pappas.rck Page 1 of 1 REVISIONS: El EXISTING DECK EXISTING DECK L-1 I I GARBAGE O � i F- t Aruba XL 118 Jet 6 Person Hot Tub Spa EXISTING KITCHEN ALTERED 0 z a EXISTING BEDROOM "' 0 0 0 ------------- 0 oco EXISTING FAMILY ROOM LLJ 01 Co LU 5'-11 1A2 "0 z2 4, 2'-4" O ---------- --- --------- t2"-6 H ---��TIN&BATH / ED Ll OFF EXISTING OPENING RELOCATE DOOR >- / - �0 [8"FLOOP DROP] F REPLACE EX.BIFOLDS LU ce UJI 0 z ct 1 0 P..4 ce -Z z 0 LNDRY- &M- CL 0 VLr-L -00 EXISTING 1-1 v ING ROOM f C, Lo EXISTING ENTRY 0:': :0 of OPEN 0 xi To Ix 2.6" ABOVE IiIN EXISTING DINING ROOM OPEN To NEW WALL ABOVE N cu &DOOR 5 0 T ----------------------------- cf) x EX. EX. 1/2 BATH EXISTING BEDROOM 14 P4 Nw 0 EXISTALTNIEREDG PORCH ME Lo N c� 1 owl dN, cill 00 Q-4 N A m� 1014 FG COLUMN w/6X6 ACQ POST EX.STEPS TO REMAIN U) 9'-4" 1.21-0l'i WALL LEGEND 2�4 ---------------- L--------------J WALLTOBEPEMOVED U0 U) EXISTING WALL U) ( INSTALL NEW BLUESTONE NEW WALL EX.LANDING TO REMAIN WITH PROPER SLOPE(TYP.) NOTE: DIMENSIONS OF EXISTING WALLS ARE FROM FINISHED WALL [INT.:2X4=4-1/2",2X6 = 6-1/2",EXT.:2X4=4-",2X6= 6" DIMENSIONS OF NEW WALLS ARE FROM STUDS EX.STEPS TO REMAIN EXT. INT.:2X4= 3-1/2",2X6 =5-1/2"] 1ST, FLOOR PLAN SCALE: 1/4" 1' e4ll DRAWN: MH/MS EX.SIDEWALK TO REMAIN SCALE: 1/4"=V-0" JOB J -y 03,2013 anuai SHEET NUMBER: A PAINTER TO PPIIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE CONAMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A�6 MANUFACTURER'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO THE COMMENCEMENT OR CONTINUATION or WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS• m'� e ii ue •.mA Y" a w.,",.� ..al I .,,i oa act A W> Y S U Li O EXISTING DECK EXISTING DECK REMOVE EXISTING BIDET, VANITY&SINK Erl CUSTOM TRANSOM INSTALL NEW SINK CXW145-3 NEW(4)RECESSED SOFFIT SPOT LIGHTS 5'.2 1/4""X2'-7" ABOVE REPLACE EX.WINDOWS ROUND TOP ABOVE �I y (3)1-3/4X9-1/2 ML HEADER I 1 I o I 11 I � s�, 1 I \ I / 1V�1 17••I EXISTINU 1 ; REMOVE i IL/Ol N -- EX.WALL BATH I ' REMOVE EXISTING _ �,---�.. r^•,,..-----•-•...,�-- REMOVE EXISTING 2'•6" WALL AND REPLACE VANITY&SINKEXISTING TUB/5I10WER 1 BATH CLOSE OFF I I CLOSE OFF OPENING I I OPENING �. � IIII IIII EXISTING BEDROOM W"" ;; WI - REMOVE Q � I I I I � j' EXISTING I I I I c, SKYLIGHT I111 nll g --------- I I I �'llil I111 -•' i ��:!: EXISTING BEDROOM I jc [t �N IIII Ilil N ' I I IIII IIII 00 I � 1 I �IIII IIII --------------' G 1 I IIII IIII � 1 I IIII IIII � � I I IIII IIII I llt IIII I ill till EXISTING 111 o BATH EXISTING HALL RE R.EMOVC'D ------------------ -------------------------- D \/7—= 71( II OPEN EXISTING BEDROOM EXISTING BEDROOM eELW , I o OPEN N TO W BELOW o /, REMOVE X , , EXISTING SKYLIGHT 0 3 2X8 F#2 HDR. t~ W ( ca y BENCH SEAT- - - y BENCH SEAT',- ----- - CW135 CW135 CW135 CW135 0 0 00 \ 3 2X8 F#2_HDR. I 3 2X8 DF 2:HDR. S'-2 1/4""X2'-7" 04 bA -U \ 1377--i CW24 CW24 --V ROUND TOP ABOVE �eMo�je 14 —0 2 —6 U y 4 —3 7 —0 7 —0 EQ. "-------------------------------- , EKXISTINV:, .-- ------------------------- -- -- --- -- - .o cn 1 _ ' SKYLIGHT ' _ -- _ -- ------__-- �'-- 15.1' I I , �I --------------------------------------, . • .----------- 1 , I 1 1 W I I I I 1 O - -- - -- --- --- I I , I I 1 I V (n 0 2ND. FLOOR PLAN �� = 1� _------WALL LEGEND SCALE: 1/4 � H WALL TO BE REMOVED EXISTING WALL V NEW WALL � ►Yi NOTE: DIMENSIONS OF EXISTING WALLS ARE FROM FINISHED WALL [INT.:2X4=4.1/2",2X6=6-1/211,EXT.:2X4 =4-",2X6=6") DIMENSIONS OF NEW WALLS ARE FROM STUDS [EXT./INT.:2X4= 3-1/2",2X6= 5-1/2"] .t� , .�' �g,,sty..•n € � Q DRAWN: M11/MS SCALE: 1/4"=1'-0,1 1< :�r JOB#: January 03,2013 SHEET NUMBER: PAINTER TO(PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK, CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A-7 MANUFACTURER'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. 15.1' REVISIONS: 01, - Lu n ` �T T }�' - C✓ - - — --- cz w iO W o • LAC L r > � a 1.. w .a Li H _L ?--' - L -� � 1 - - - 1 w � � _r 1 _ � � 1 _ LL _ f u H r 9 • � - r J r f �l J`.-„ �;J ) � �� I/ �;..J(- J �y,.-J" '/"`�, �� J )""< r �,,,_--S._'j,`�"-=. ) _'3•,� �J''�) �( K.J�: ry ( ;g�31r`�". �--_ J"'z„, ��- J,,,,_ --;.� .J;...:2:..%' ,.•�`` �� �.-. �.�•.l", .. p'•C„+..�:.---�-,^`'}L"��jt� t� �? _ �#/ _,;..,e+':;ay"'`_� ��+�a,�,.- "w° �L .. .,.A`'�' ...���- �.� �"�.Y... e..,'��,��`"'`" f .� \ - _._--__.__:__.__- I �) �\.i� L !,'✓� � t-,I- �'L. :� r�..i�J/^ L� 1 <'\✓,.y.iyL 1.;.;,� Y( ( ;��•,"� ( 1...,,� �� f `r`.¢..+_,f ����� t 1'� ',.d J'�a-i / � �-� /, / `�' I.;..-,. •�..,�.: { ,..�'-.^, ,r/1�' ,.x;..-.R_,•�^_ as:..a,..�._ i <,- _._. .-.-_. z:i ��...� .-,._ ,.x;, >.y .._'.,... .., ,�.r, ,..-. ��.�" -._ ,,,•.�_�.., �.� -.., _,�....:,.; r--. K.,..a >r.a.> .(�j a =C-.x - `,,-�t�'..`e� �.i ,,,'jti - - „f.� - �,..o' .�°`• \ _l 1,�"'- Yy--� `'r�'r {� y,7� )'�..`�( ......r )` (`- I' �,..J J -�{ .....`af )i ��..`�r-l- �(y �J�.; -�` �`J(� �"` �,lr„,-7, .tv-i..�, ..��j.;,.a: � :f..-� _.� �-� _.- __...___ ), ��^�A {� ��,��5-,,1. �,�y�(w_� �{{�' '-�'sy—,�\' �. �'a,�.�-t'"'� y�,G- _� ��'- � ' 1--� t l �"� .0 .I�J�( },� Il�'.,'�✓" `mY'��1~ � _•_�� l � �( )% Y�-J`,�;1. -j(�������--�';f��`lI""j`'�.��( `=-=�. > 1,�4r �-�� � - �..;_} ,r, ';�-� ,> � �� �:,' �, L >���� .,. � ,. � � � �.�:���yam- �T � ,�• .p�. f,�, _ 71 FRONT ELEVATION SCALE: 1/4" = 1' � N Utz}R� Yf�t YG Y ky4 1 Sa X Mq O M IN1,',- DEPART IENZ AT o � ! 3=" [.(kj. G. PNl FOB THE G I;°SSFF�CTIOMS: .. ,- _ VVOF�EC�UIREQ � t� EC�OO.NCRETE U lr , 00 CAU;LKI,NG CA .. � W ✓ :ONSTRU:CTiQJII!&ELEGfRICAi_ 8 (�3MPLET FOR C.O, ,,ST} aJgT!ONSHAL..L MEET THE feUd! f�1hE1TS OF THE CODES OF NEW Y� u�STA�T NOT RESPONSIBLE FOR cn I �Qf1S:TRJCT{©�yE7 CRS. W - H PLUMBER CERTIFICATION v ON LEAD CONTENT BEFORE p CERTIFICATE OF'OCCUPANCY SOLDER USED IN WATER SUPPLY SYSTEM CANNOT EXCEED 2110 OF 1%LEAD. d PLUMBING' ALL PLUMBING WASTE u &WATER LINES NEED x TESTRI'G EFORE C';V-RING w f�-��' �� 'yam•` �„��C,.. �� DRAWN: MH/MS SCALE: 1/4"=V-0" Rt- n JOB#: November EXISTING FRONT ELEVATION . � ` %� ,,;s ',, "+ k" SCALE: 1/4" = 1' SHEET NUMBER: PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMhAENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A- 1 MANUFACTURER"5 WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOIR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: "XI Tc- H�"E Z T -T .L L -T- 0 11 IT I IT I r Tl L C) I J 1!J D .7 t T F 1.41T J-1 F -i rYL-1 T- T j'T wy( I T ri J-1 7 0 00 I A, '41 -A— rm 1-1 w E3 RIGHT ELEVATION SCALE: 1/4" V P-4 ct O Tzt (2 6 .4 M Q M 00 to U 71 ON cc 00 cq Gcu U) u 0 U) U) �-j rx U) 010 0 0 0 E3 0 010 1 0 E3 Ml 1110 o �.e�:rW o DRAWN: MH MS 1. SCALE: 1/4"=1'- 0 JOB#: November 16,2012 EXISTING RIGHT ELEVATION SHEET NUMBER: SCALE: 1/4" = V ) PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCINGWITH OWNERS FOP,APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING MANUFACTURER'S\WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR ITO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: � � — _._._ _...�_ � _..__...-._�g__r'..e_.__ _•_ v�— --�_._______.,.,_sr__.__�w_--_s__-.._..ae��__sm_—�ram__—_ - aH .rra.v-___ ________..saen._.__aw.✓___.__..—.__..__ _ _.�vwma�..._..—. - `ma's _- _ m a. — - l L i TL F FT E4. w f 88 W �___,'. 1 I 1 � M-L Q i ---- REAR ELEVATION �_---= SCALE: 1/4" = 1' H cc3 n M O M N cu c M � � m o rn z Gt � � c" U y �w vein N v 0 W W A .. . . hh r-i U O N d U }' xs?: e `: ,• o DRAWN: MH!MS // t-a� •, ,lr SCALE: 114"=V-0" EXISTING REAR ELEVATION � � :..�R.T JOB#: �,� a`. � November 20,2012 SCALE: 1/4" = 1' , ` SHEET NUMBER: PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A-3 MANUFACTURER';'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOIR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: 4 TTi U t L - K, __L.. i._l _ 7~- -.I._.1 T1I. T_ L _._I _ r�_ _ I _ _ l�. . _ - T I Z I L .7_ __J .. 7 T11111 FF rrY � T ---JET �._ � �_ --[--1-�-� .�I_ � _ _ l . I 1 T- - - . I _ I__.__. - - _ ___ '1. _ - ___ H { rIT- '' 1__ i L: I I Z:1 __ C_IL IT_ _ 1 � w r .r T _ _ _ _ _-lr r._'_ ___ �. _.. _ __ i J._ .L_. .. _ _ �. _,Z _ 1_ T _ �_ YL �. Z_ l 1 �. C — -r�_ It- - 1_�__ _r_ __ . 77 _ - ' . . - . •. .. peel ., , .. ._ LEFT E LEVATIO N SCALE:: 1/4" = 1' O °x n M O N � Q\ Lo m O a, X O � tSr W 2 a4 a� L Lf, u in N G 9a � W EEO, El - W f..i cA N H d U DRAWN: MH/MS EXISTING LEFT ELEVATION SCALE: 1/4"=V-0" JOB#: SCALE: 1/4" = 1' �' Y:.�:M �,ti M November 16,2012 L i SHEET NUMBER: PAINTER T O PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE:COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A-4 MANUFAC:TURER'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS, REVISIONS: A ❑ --u--- ❑ ------II--- Q----------p I t 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 I -------------------D.- ' ❑ :------------------------------------------------------------------ ---'---------------------------------------------------------------------------fa ❑ :------------- ---------- 0 EX.(2)2X10 EX. (2)2X10 EX. (2)2X10 EX. (2)2X10 E)X.(2)2X10 �I EX.(2)2X10 EX-(2)2X10 EX-(2)2X10 EX.(2)2X10 ; ADD(2)2X10 ACQ REPLACE ALL 4X4 POSTS ADD(2)2X10 ACQ REPLACE ALL 4X4 POSTS ADD(2)2X10 ACQ ; TO GIRDER w/6X6 ACQ POSTS TO GIRDER w/6X6 ACQ POSTS TO GIRDER 1 VERIFY PIERS(MIN.12"dia., ' VERIFY PIERS(MIN.12"dia., ' T BELOW GRADE) zc T BELOW GRADE) ; I i v 1 1 z , O I ' zcc 1 re 1 ' 1 1 X , 0 8'-0" 8'-0" 8'-0" h 7'-9" 8'-1� " 8'-0" 8'-0" 6'-6" 6'-91/s" 3'-4" I 1 I co ' NEW(4)2X10 ACQ GIRDER NEW(4)2X10 ACQ GIRDER NEW(4)2X10 ACQ GIRDER NEW(4)2X10 ACQ GIRDER NE\k(4)2?X10 ACQ GIRDER NEW(4)2XI0 ACQ GIRDER NEW(4)2X10 ACQ GIRDER NEW(4)2X10 ACQ GIRDER N_ C412X10 ACQ GIRDER ; 6X6 ACQ POST w/12"die. 6X6 ACQ POST w/12"dia. CONC.PIER T BELOW GRADE ; C CONC.PIER T BELOW GRADE zo O 0 Cc i ® ,—�' 1 RE-BUILD EX.RETAINING VERIFY CONDITION OF EXISTING LEDGER. 1 REPLACE f ADD FLASHING AS REQUIRED. I 1 X6 ACq POST ON . 9 WALL 1 SECURE LEDGER TO HOUSE WITH TIMBERLOK® 1 2"dia.CONC.PIER 1 SELF-COUNTERSINKING SCREWS BY OLYMPIC ' 3'9ELOW GRADE I a 1 (4)2X10 PPPER DECK GIRDER MANUFACTURIP40 2 SCREWS @ 32"0 C. ' , ya 1 1 1 1 A , O 1 1 1 1 1 ; H 1zcZZ cc Cc on E-4 1 LL 1 � 1 1 1 i 1 1 1 , I 1 1 ` ':RETAINING: . i 1 - - - ` - - - - WALL _ ' 1 EX. (2)2X10 i 1 it O O EX.POST EX.POST ___ EXISTING DECK BOARDS EX. (3)2X12 AND RAILING TO BE rA REPLACED NEW STEEL LALLY COLUMN aON '----- UP uP ------, DBL. UP DECK JOISTS� .- - -, CONC.NC.F FTG.G. 1 1 M " i 1 1 1 NEW(2)1-3/4X9-1/4 ML w/1/2"STEEL PLAT --IEW(2)1-3/4X9-1/4 ML 1/2"STEEL PLATE M a— -• a—-——— a- ----------------------- NEW STEEL LALLY COLUMN 0 ON 24"X24"XIT' CONC.FTG. VA2DD 2X10 ACQ NEW STEEL LALLY COLUMN � TO EX. GIRDER. ON 24"X24"xt2" INSTALL SIMPSON CONC.FTG. c POST CAP AT EACH r I POST, THRU-BOLTED (2)1-3/4X9-1/2 ML GIRDER (2)1-3/4X9-1/2 ML IRDER a 1 . — . — . — . —,. . .,.� . . _.. . O REPLACE 4X4 POST o CL I w/ 6X6 ACQ N v �! 4 I • m 0. 1 ,y Q rn 1 — " 8'—11" 8'—1 O�/2" 'W STEEL LALLY COLUMN Lu OCONC. 4"x12" o ; PARTIAL SECTION LO NEW STEEL LALLY COLUMN CONC.FTG. O cf) 44 ON 24"X24"X12" 0 I � � � � CONC.FTG. ' d `� A SCALE: 3/4" = 1'-01' �; } U c N EX.P05T I o oo41 1 u a---------- --------- --- �}+ ' co v ` cl � _j ►n V vein N .0 W EX (3)2X12=====____ EXISTING CONCRETE STOOP ,.,-EPDXY IN#5 REBAR F-F (TYPICAL) a A W Ppi 1 CONCRETE PIER w/�L — — i L — — J 36"X30"CONC.FTG, T-0"BELOW GRADE �- OCUT STEPS„ '—O" FOR PIERS N H d V DRAWN: MH/MS SCALE: 1/4"=V-0" , JOB#: November 20,2012 SHEET NUMBER: PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A-5 MANUFACTURER'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: 1.14 El I 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 I 1 1 1 1 1 1 1 I 1 1 1 1 I 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 1 1 I i I I EXISTING DECK EXISTING DECK 'w I z C I 1 GARBAGE � O 1 1 W z 1 1 a O O EXISTING KITCHEN a w ALTERED EXISTING BEDROOM o F— < = 2'-4" _____________ ° ° EXISTING FAMILY ROOM Q w W z 1 1 ' N it Ia-- _ - --- ------ CLOSE OFF EXISTING OPENINC RELOCATE DOOR - EX14IING BATH - - - - - �— ALTERED ^, � D� j [8"FLOOR DROP] REPLACE EX.81FOLDS tL.J W o N w � I � O -la. - - - I o I I 1 1 1 1 0 I I 1 1 1 1 of N I I Lu I EXISTING L1 v ING ROOM ; oop 1 I 1 1 r x EX. L DRY. RM. I I o;1; 1 ;O ALTERED I I EXISTING ENTRY OI OPEN::�) , 'o II x�l; TO ;IIx 2.6 I I OPEN ,y ;CN ABOVE EXISTING DINING ROOM I I 1 TO NEW WALL I I ABOVE 1 ; 1 ; , I N a &DOOR -------------------- 1�' E 11 ` ---------------------------------------�. x G In iI . C;-, v EX. 1 2 I I o � BATH EXISTING BEDROOM o � U I - EXISTING PORCH �0 N 00� ALTERED N N � � cV i o+ ( m 00 N 14X14 FG COLUMN N -; w/6X6 ACQ POST EX.STEPS TO REMAIN U) W 9'-4" '-0)" WALL LEGEND WALL TO BE REMOVED V EXISTING WALL 1 ( INSTALL NEW BLUESTONE EX. LANDING TO REMAIN WITH PROPER SLOPE( YP.) NEW WALL N NOTE: DIMENSIONS OF EXISTING WALLS ARE FROM FINISHED WALL Q [INT.:2X4= 4-1/2",2X6=6-1/2",EXT.:2X4=4-",2X6=6"] DIMENSIONS OF NEW WALLS ARE FROM STUDS EX.STEPS TO REMAIN (EXT./INT.:2X4= 3-1/2",2X6 = 5-1/2"] fj 1ST. FLOOR PLAN . a SCALE: 1/4" = 1' A S _y^J.����� EX.SIDEWALK TO REMAIN +"s DRAWN: MH/MS SCALE: 1/4"=1'-0° JOB#: November 20,2012 SHEET NUMBER: PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A-6 MAN UFACTURER'S'WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: A�^ O E-� EXISTING DECK EXISTING DECK CXW145.3 NEW(4)RECESSED SOFFIT SPOT LIGHTS 5'2 1/4""X2'-7" REPLACE EX.WINDOWS ROUND TOP ABOVE o O O (3) 1-3/4X9-1/2 ML HEADER ' Q �___________ EXISTING Ti-.-------__ REMOVE , N \ / EX.WALL O BATH I REMOVE EXISTING \ ~ VANITY 6.5INKEXISTING c /)/ BATH CLOSE OFF I I CLOSE OFF ; F� OPENING I I OPENING Fri c+t } an EXISTING BEDROOM +; REMOVE f EXISTING I I I I °Ciii i -------- SKYLIGHT I I ., ENLARGE 6� I I O AL sHo ;--- -- X EXISTING BEDROOM00 V I (� IN�i�i iiii IN nQ 1 I (EXPAND WAIL ^�un un -1 ! �' I I OPENING� i �� nn un EXISTING CHANGE ,i„ \/ DOOR SWING BATH EXISTING HALL o - it ) "' EXISTING TO— -- � / E REMOVED ------------------- -------------------------- DINr� (7 I�' r + ®REL EXISTING BEDROOM EXISTING BEDROOM i i'y •�B OPEN N iv E TO I cf) 4 O W T T BELOW , a` n +V. , / i REMOVE 'COO p - EXISTING u SKYLIGHT i I/ ' (3)2X8 F1f2 HDR. u 'd (d >~ BENCH SEAd- J BENCH SEAT'. - ------ 3 2X8 Fi/2.HDR. I 3 2X8 DF 2 HDR. CW135 CW135 CW135 CW135 0 5'-2 1/4-X2'-7" O l I -_, ROUND TOP ABOVE cn CW24 CW24 14'-0" 2'-6' U a 10. 1. Ln ---------------------------------- i -- ------------------------- -------------------------- v -- +' ------------------------------------- .-: :- ----------- Lu 0.. A O / ----y - - - - - - - - - - - - - - �--- O 2ND. FLOOR PLAN- SCALE: 1/4" = 1' -----_-WALL LEGEND H WALL TO BE REMOVED EXISTING WALL V NEW WALL C.I.) NOTE: DIMENSIONS OF EXISTING WALLS ARE FROM FINISHED WALL [INT.:2X4=4-1/2",2X6= 6-1/2",EXT.:2X4=4-",2X6=6"] DIMENSIONS OF NEW WALLS ARE FROM STUDS [EXT./INT.:2X4= 3-1/2",2X6= 5-1/2"] Al DRAWN: MH/MS SCALE: 1/4"=V-0" JOB#: November 20,2012 SHEET NUMBER: PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT Of ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A-7 MAN UFACTURER'S'WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK, DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: / I /F - !-;! f /r i-f f f f /' i%' r t < �/ /' f/ rr < /! ;• /• f f f it ` , d -/- - - ----------------- ------ -------------- _ -_-__- J ---------_-- - ------- w -- ----- -- '---, !''��'J %' //� /•� J J i i ! // //• � /� / r ,rl � //// /� ! / I I/ j' ,' i J i /` /i t / / /` J %• J/ `•/' / f ,'9 t/ /// � 12 I I /I i i JJ / / �/ // /� J• /, /. / / % t/ r / / / /� n' 1 / / / %/ / i '/1 i// / / / !' '' j / •/ 2X10 RP _j .L I p16"OC Q� 1,4 EXISTING, ' ' i / i //! / ' / ! J/, J/ i/ / I r %/ / // r/ I /'• / ! r'i /, / i l // JJ 1 ' / ! /' !� '' i /r• J /` I/lr r'/ /J // / x ^ 1 fi I / / r / /, J / / i I ✓' ! � / ,r I JJ / � JJ / / j Jl /, / /• /' / it ! / /' / I i/ / `F/ /, f ,% / /i�.'/ JJ !/ /' /� 1 -�i�� 'i !! ,/ % � �/ r i%%�,"`7`�;/..._%�,:__�,.��,_-.�_...J�/_-�,�_./J•__/'_-y I I;''J % �/ f j /, ' / i' /' %/ // /✓ JJj +/% j J� // /' #t,: IY' /``lJi/� j ! / ,! /t r' / i / i r�i i; i; i%� J' /' Ji / I/// •, I / �i / / / / / / / J ♦ I I _� /JJ` ' J j// J''/'J / i! // /'/ // J/ /' / �/ i /I y�/ / / / %, � /( +/ / // / � J/ %r'j' j/ //i 5/ J J/i i /J/ .✓I r % J%/ /' /' J/ /� i / / // /' /J %• :'' � I 1^', ,r'I iJ/ // // /! % /J / / 1 1' / !// / /i / i / /� J!' / !J / I �/ J' .���.,\ �.f' /• t '� / /J: i- j / ,/ ! j• j j' !' i-' i / i r i �% / %/ / / i`( / /% � /' ! /J yil % / /•� I J / / % ! �1 / �+l\\ � •.\, r JI/' ,✓ /' +% r'I , %r /` /'' ' % r' ' / JJ !' / / I �,i /. 12X10-RR, l \ i li '�' i % i'r ' /� / % ! :� ! ✓ ,! /, j' / /I '! r., �jl'6"OC '•� i ;/{ I % ,/ j' + I•"' % � % i / /• !/ / / / / // I� i // I/• ,/' /, r j ✓/ / % / / / %i i / // t/ !/ , ✓ !! /� i/f __( J!_ ^/- J! ! -'r=�- / // 'y_ _ ,j _._ _. , .1!� _ _J_/ % / /� + //_' _ _ I� / J/`ham \ \ t /'__i ' /' _ / ' ' /J' %' 1. ! ,/ fJ� !' i /r i // '% i i" /f� /, , .✓ _f' r/--�� -y- �-'7i- 7 -- y / j- -- /! -,r'--7 -� ! J'' J r/ / / / // !/ i // ✓1 I % ! * r , I / !J r J / ,J// i / j / ! / � f? / /! ,/ J� i / / / / /' J! /' / J / REMOVEEEXISTING /' J SKYLIGHT,(CLOSE OFF! / , 3 ! ✓ % / i / !" / / /// i J J Ji / j / i 1 /4X9�1%2 M1 HEADER OPENINtG(TYP.) / !` / � ! / ''/, %' !/ j/' %'r`//% %r' / !/ ' ii/ �' �i, ! /J �i/ J� /•' % // /r /r / ✓% ! / i J Ji/ F J /, / % r/ / J/ / //%J / �rf/ ! /It . // // !`Y�•Y // !J J'_ /// / j' /! // iJ %' /! J/J/ y ,i,iJ /,� J '/i //••!f>�J f/��/`/j / /l / I.��//�F/''�" ;' ,�-�_/`.�-/-(r-,f__ »/,1_�-'-�-,�Y -/�� yf- / 11. j ,J J !/ %`j ;'' / i + J. / /. - / %• Al _,.! i,- '�=- -7'---- - _ ___--- ----"-- -�'-- _.�_ % J�_J'' -'/ REMOVE EXISTING J t •! - ! ../�`/' / I'/ / rr t /! IJ+` / /i / ! / !JI /i /I" I i i /i J !% i' / / %. /. . _j,. { i DORMER -7'' ,�f_ -� J'f, •/ // / /� /` i r' /% / J ' // f .J // I��� /' � / /' '�/ � /' I I/ I! '"J'` �y / _ _ '••'__r�..._i_� !` I%�f t r: / r r / 1 t/ / 1 ! /, / JJ /' /r / , / �,r�/ i' % J� ,/,/i ,�.,// /' ! / !' `r '' t! I 1 ✓ / 1 % J / / i r , Ito,, i :lll ii % / � / '_ 7�W�,J%� l _'__;/,�y_ yy/_-y! ./7/, / J!` /i t./ ' `J // / / /' %/ /r// /I/// / + r` /�• ! ,!^/ J`/ !/' / // %/ I�f—/ %/_ / j 'J/ ii'/ J,. f/ / r /r »/ /''J'` r J j J/ ;'i ,erg /' i J JJ I Y ! ,.i 1// � �•/' / � / �/: /, J,. !, j / ✓/ / I� I I IJ / ,!, i! �1 /• / ! / t//I / / / r' / / / /I / /// / / / / % /�! f / /" % ' i' .'w a + 'W //I I/ N w / jIce 'I +/w / j' r r' ! r/ ! // /l.i !! f 1 /'� I/� % J / /! J/ co lIm !I J aC' rf Y ! / of i t r/ / i 1' /r / ; / i/ /" / 'i % i' t''VY a+ � I 1 I N t i N , / N! ✓ J / / %J ' i �` J J' J.J / J 3 , I I 3 �. I / ii i:J / JJ �/ Ji'r 2XI0 PP REMOVEEXIISTING ;! / !i , !'/ I; y IIIIL % �X ,/' X /! 'JI ' l '/ ,/' / 5t ' +i J' // "2X,1tS RR/ /SKYLIGHT,CUOT�S/E 1OFF I�'I % N• / /%, ,ry� •1 i Nll / iJ / N/ ' ,1 / 1,r ) .� I JJ /' J/ � !i 2 2.3�10 #2 DR:/ 'I , :i M'1/ / 2. 2X10 DF#�HD72. / I^� / !, /' / �16"OC __t OPENING P. J///J !/ !/ J'i /! xi I i 12 '/ / / i�T"�" .��,. �� '''�/ i .4 I i+■.+''. ".ram ■'�r J• �` % I ,f / ' i •\ \\ \� rJ i � / J' i ,�•+ �1 / I! I ,/ / i i /I I/. � / j / / %r I% / / !� �`.� � .\r,• J %� // / / �� / % .m-I ' S� + iM �!,( ! 1,.1 %' % '�/ ! ' / ! ri/ ,/rii :/ t i' ,/ • ;' 4y/ /I ! % I/� ,i ! r. ,`\ \ \I J J /' i / ! / "I I + / J i w /i w ''� .' ,� %` J '�° A ,/ r 911,. / / I/y;/ / � Q ll' /'r! /i � i.! r/J i' �� ,. \, ••'\. .r ✓ / i/ J/ / / ,/' i i i I , �` t i O /-r - - -- j3)1-3/4X9_1/ ML HEADER- cu 1714 12 ' /I !f r / -/.. //_� ' 12 Q i / J/�" / �� // i/ i/J /� r/// J J /,i!r/ J'i�% � f�� r• N X ---- / / / ; � r ���/// `� 16"OC / // OL / % ' / / ' �/ J, i j / / ! ' / /' r / r J CC M to O 1 y' 16"OC i FQ / ! / J / / / / ! / /' !~ /' i / / / 'i �� v Cl U / --------------- ---------- ----- � % }+ w th ------ --•--'------'---•- y XISTIN i.r-,/-- - ``-f- /-- f'`- { -._*�'.--/•--P/--Y--s--'- i ��` ^i-_f I r 7%I / !// / /' / !/• ./ '/ /' / J/ / ! /' % !'/ - , / / / I y _ y/_ /�_. .. /__.�... �.`.�_ = _7�- _ _./ i. _r_- %"_i i/ - _/__ /r N ' /'i I r /• / / 1 / J !' % J !' / / /r / f// r /r / '/ I w + ! J' / / i' ,! / / %~ / // ! / ! % r Ln 00 ++ \ 4 /', �/ / %/ J/ % %, iJ //!/j i.✓` ! - r!_�G-%,,,t_/c._�,_.__,:_%__,/_f! i` __' N - - -T- --Jf' �,/ J! j J/r i�// /' '//, /` j i / / / J'�' j J /' �..I a'•r-4 f t/s ri iJ rJ, / / // / / !i I'/•' 12 N � U m N 1).GENERAL CONTRACTOR TO REVIEW EXISTING CONDITIONS AND CONTACT 6).ICE&WATER BARRIER TO BE USED IN ALL VALUES AND INTERSECTIONS �1+ ARCHITECT FOR ANY DESCRIPENCIES OR PROBLEMS WITH EXISTING CONDITIONS. WITH ROOF AND SIDE WALLS(TYPICAL). N v 2).ALL PLATES SHALL BE BOLTED TO RAFTERS WITH 1/2"DIA.GALVINIZED 7).DO NOT INSTALL UNDERLAYMENT ON WET/DAMP PLYWOOD!!!SHEATHING LAG SCREWS WITH WASHERS AT EACH RAFTER. MUST BE DRY AND CLEAN PRIOR TO INSTALLING UNDERLAYMENT, % ✓ -�=- i i-- �-`�--//" ---- - - ------- -------- ---- ----' UNDERLAYMENT IS NOT TO BE LEFT EXPOSED TO ELEMENTS AT END OF THE i i' J / ! // � jJ ;J ri' �----- - ----- ---•----- ---------------- --- -- • 3).APPLY 1/2"THICK FIR CDX SHEATHING OVER ROOF FRAME. WORK DAY.COVER WITH HEAVY-DUTY TARP UNTIL ALL ROOFING IS COMPLETE, 4).APPLY METAL DRIP EDGE OF ANY UNDERLAY ALONG RAKE EDGES AND DIRECTLY TO THE DECK ALONG EAVES. 8).INSTALL ASPHALT ROOFING AS PER MANUFACTURE'S WRITTEN INSTRUCTIONS. W ROOF PLAN USE GALVANIZED(ZINC COATED)ROOFING NAILS,11-12 GAUGE WITH AT 5).USE 30#FELT UNDERLAYMENT WITH ASPHALT ROOFING. LEAST 3/8 DIA.HEADS,LONG ENOUGH TO PENETRATE THROUGH PLYWOOD. i i USE 6 NAILS PER SHINGLE.NAILS ARE TO BE FLUSH WITH SHINGLES BUT NOT u SCALE. 1/4" - V CUTTING INTO SHINGLE SURFACE. o d N Ey d V U) p ",� :�•�? a- DRAWN: MH/MS SCALE: 1/4"=1'-0" JOB#: ' • ,� „fi November 20,2012 SHEET NUMBER: PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMIENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS MANUFACTURER'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR.TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: 11-7/8 ML RIDGE EX.RR (2)1-3/4X11.7/8 ML RIDGE pq DBL 2XB COLLAR TIE EX.RR O � (2 1-3/4X9-1/2 ML EX.FJ C) DBL 2X10 COLLAR TIE ,,, Q; O Lu LIL ES � <,. EX.FJ Q EX.D1 EX.DJ EX.FJ d. °• EXISTING (2)2XIO f"•�• GIRDER ERR � � ♦ 6X6 ACQ .. POST .Ib a •: EXISTING BASEMENT EXISTING GARAGE P' ct I--d +a 12"dia. NC. PIER SECTION A-A SCALE: 1/4" = V-0" cn N v O X CG 0 .� O 4- {r y o� a I I I I 24"DC +" 0 r / / w 1 1/a 1 1/z 1 1/4 1 v4 1 1/4 1 1n 1 vz 1 vz 1 vz 1 1/4 1 v4 1 1/400 1 I LAV. LAV. STAINLESS STEEL {� r ( { { i( tl { f i 1 W.C. W.C. BIDETI W.C. IBIDL71 11 1 I ((( OR GALVANIZED WOOD SCRE WASHERS WS W/ I " I I( I 1 12 O.C. � I I" � I � ( � SHOWER SH ER SHO VER BA rH I i lz" I ' 12"D.C. 12"OC I 20 2 11J4 W I ` �� ` ► y 3/4"APA PLYWOOD C.O. 3 1 1/4 C.O. I 1 t/4 3 3 3 2 SHEATHING 3 I C.O. 1/7'APA RATED SHEATHING I 1 1 I (ALTEERNATMVED7/16'0.5.B.) ' /I/2"APA RATED SHEATHING O GRADE PLYWOOD I 1 1 J I (ALTERNATMVE:7/I6"O.S.B.) I t I I I I I Tli 11/4 410 STAINLESS STEEL '{ ( I /{ ( 1 I 2X4 OFf12 I i 1 1/4 1 1/2 1 1/4 1 1/4 1 1/2 1 1/4 � OR VANTZCU STUDS WOOD SCREWS W/ ` / WASHERS v 12"O.C. ' \ ®{ I ]J' m LAV. SINK P LAV. 13 { 1 ( I WINDOWSILL { J � w s{) f w{ ( W.C. W.C. ( I f I TYPICAL WINDOW OPENING { I W.M. D.W. I I I I i (LESS THAN 4'OXS'0"OPENING) I t ( I AIO STAINLESS STEEL B H S 1 OR I - W ODD - I I I t 1 OOD SCREWS W/ WASHERS f@ 12"O.C. TYPICAL DOOR OPENIN(n I I j t 1/z 2 3 z 3 MULTIPLE PL SrUOD ASSEMBLIES C.O. 1 1/4 C.O. I 1 1/4 (LESS THAN 4'-OXS'-0"OPENINVG) z-zx4 DFxz sruos CONNECTED �LI TOGETHER WITH STAINLESS STEEL L3 C.O. OR GALA IZED BOLTS W/WASHERS AND NUTS 0 T-0"O.C. 3 3 TYPICAL MULTIPLE OPENINGS ~' (MORE THAN 4'-0X8'-0"OPENING) k WIND-BORNE DEBRIS PROTECTION FOR WOOD STRUCTURAL PANEL SLOPE" 1/4" PER FOOT PITCH TO DRAIN TO APROVED A'S PER TABLE 1609.1.4, N.Y.S. RES. CODE: ALTERNATIVE FOR OPENING PROTECTION (IF NOT USING IMPACT GLAZING) ;.. - 4"C.I. SEPTIC SYSTEM �'+x WIINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS WOOD STRUCTURAL PANELS WITH A MINIMUM THICKNESS OF 7/16" TRAP HOUSE �' BRAWN: MH/MS AMD MAXIMUM PANEL SPAN OF 8 FEET SHALL BE PERMITTED FOR OPENING PROTECTION IN ONE-AND TWO-STORY BUILDINGS.PANELS SHALL BE PRECUT TO PLUMBIING SCHEMATIC �;` " , 1/4"=V-0" COVER GLAZED OPENINGS WITH ATTACHMENT HARDWARE PROVIDED.(REFER TO SECTION 1609.1.4,1609.6.S AND TABLE 1609.1.4 OF N.Y.S.RESIDENTIAL SCALE:4" ; CONSTRUCTION CODE).THIS IS NOT A SUBSTITUTION FOR DESIGN-PRESSURE.ALL OPENINGS MUST HAVE DESIGN-PRESSURE UPGRADES WHERE APPLICABLE. w t' JOB#: ALL PANELS MUST BE CUT TO SIZE AND READY TO USE ON ANY NEW WINDOWS AND DOORS,SHUTTERS MUST BE MARKED FOR WHAT OPENING IT IS TO COVER. HARDWARE MUST ACCOMPANY SHUTTERS FOR INSTALLATION. N .T.S. �`!.�, ;:,},,,L � /.. November 16,2012 ., SHEET NUMBER: 11 in PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS Aw7 MANUFACTURERL'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIO)R TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: WIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS USE THE FOLLOWING APPROVED USP METAL CONNECTORS FOR PROPER WIND RESISTANT & GOOD CONSTRUCTION. FOLLOW MANUFACTURE'S RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY. KING STUDS • • ENDWALL RAFTER WALL STUD CRIPPLE STUD :• 0 BOTTOM PLATE o HEADER ; RIDGE LEDGER BATHTUB DOUBLE JOIST SIDEWALL RAFTER JACK STUDS FLOOR USP NUMBER DESCRIPTION APPLICATION HC)LD DOWN CONNECT TO 1 SIDE OF ALL CORNERS 1_�T. ADS5 ,ANCHOR TO FOUNDATION W/ ANCHOR BOLTS BATH / SPA TUBS TO HAVE A DOUBLE FLOOR JOISTS UNDER FOR ADDED SUPPORT CONNECT TO 1 SIDE OF ALL CORNERS ON LOCATION USP NUMBER DESCRIPTION APPLICATION LOCATION USP NUMBER DESCRIPTION APPLICATION RAFTER SIZE USP NUMBER DESCRIPTION APPLICATION SUPPORT EACH WALL RUNNING PARALLEL WITH THE FLOOR 2ND. ADS5 HOLD DOWN BOTH BOT. PLATE OF 2ND FLOOR AND TOP ALL OPENINGS LSTA12 1-1 4"x12" 20 a. STRAP APPLY TO EACH JACK STUD ROOF LSTA24 1-1 4"x24" 20 a. STRAP APPLY OVER RIDGE TO EACH RAFTE JOIST DIRECTION WITH (2) JOISTS. UNDER WALL. ANCHOR PLATES OF 1ST. FLOOR. CONNECT THROUGH / g / g 2x6-2x8 LS26 18go. SLOPE HANGER APPLY TO EACH RAFTER / LEDGER FOR JOIST NOT DIRECTLY UNDER PARALLEL WALLS, PROVIDE HE FLOORS TO EACH OTHER W/ THREADED ROD. ALL OPENINGS RT3 OR RT7 TYDOWN ANCHOR APPLY TO EACH CRIPPLE STUD 2X10 LS210 18go. SLOPE HANGER APPLY TO EACH RAFTER / LEDGER BLOCKING ®24"OC O WALL STUD F--1 THROUGH-ROOF EXHAUST C/] VENTS SELECTED AND � LOCATED BY CONTRACTOR w E-+ Q METAL STRAP CRICKET AT TOP-SIDE OF VENTILATION CHANNEL � Z RIM BOARD CHIMNEY AS REQUIRED RAFTER SILL PLATE(S) ' WALL SHEATHING RAFTERS MAINTAIN AINT VENTILATION U WOOD JOIST AG SIDEWALL FLASHING VEN FOUNDATION TOP PLATE BLOCKING FINISH WALL AND MOISTURE 2x4 LEDGER BLOCKING BARRIER TO LAP FLASHING ; 2x4 SOFFIT JOIST Q STAPPIfNG TO BE ATTACHED TO WALL STUDS @48"OC AT WALL -- MAINTAIN GAP ATTIC SHALL BE PROVIDED WITH A FASCIA C U AN ALL WINDOW/DOOR OPENING JACK STUDS BETWEEN WALL FINISH AND MINIMUM NET FREE VENTILATING AREA FLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION ROOFING TO AVOID SOAKING WALL STUD NOT LESS THAN 1/150 OF THE AREA OF GUTTER THE SPACE VENTILATED. ALL OPENINGS WOOD GIRDER INSTALL 4'0" O.C. .' SHALL BE COVERED WITH CORROSION- 4" - 8" LSTA24 1-1/4"x24" 20ga. STRAP AND JACK STUDS '� , • RESISTANT METAL MESH WITH MESH ONTIN. SCREENED VENT ^ ON ALL OPENINGS PROVIDE HEMMED EDGE AT OPENINGS OF 1/4 INCH IN DIMENSION. CONTIN. SOFFIT / EXT. PLYWOOD F--I INSTALL 4'0" O.C. FLASHING TO FORM CHANNEL LOCATION USP NUMBER DESCRIPTiION APPLICATION 8" - 14" LSTA30 1-1/4"x30" 18go. STRAP AND JACK STUDS AND SO AS TO MAINTAIN AIR SOFFITED EAVEGAP TO PREVENT CAPILLARY CONNECT TO ON ALL OPENINGS ��„ ACTION 4" - 6" RAFTER RT10 10-3/4" x 18go. TYDOWN ANCHOR EACH RAFTER PROVIDE BLOCKING BETWEEN JOISTS THAT ARE SPICED AND INSTALL 4'0" O.C. ROOF VENTILATION / OVER BEARING WALLS AND HEADERS - - a. TYDOWN ANCHOR CONNECT TO 14" - 16" LSTA36 1-1/4"x36" 18ga. STRAP AND JACK STUDS 8" 12" RAFTER RT20 2118" x 20,' � ' � / g EACH RAFTER SOFFITED EAVE DETAIL ON ALL OPENINGS .' ,' KEEP ROOFING NAILS OUT ' OF FLASHING 2ND. FLOOR WALL ' ROOFING LAPS BASE FLASHING 4 INCHES RAFTER BASE FLASHING WRAPS CORNERS, RIDGE CAP OF SAME EXTENDS UNDER SHINGLES AT MATERIAL AS ROOFING SIDES 4 INCHES AND LAPS NAILED TO SHEATHING SHINGLES AT BASE MIN. 4 INCHES THROUGH VENT C) O O � WOOD JOIST U •• 01 7� E�• TOP PLATE GIRDER/HEADERPoo J) E- SIDE WALL FLASHING WOOD JOIST 1ST. FLOOR WALL STAPPING TO BE ATTACHED TO WALL STUDS ©48"OC AND ALL WINDOW/DOOR OPENING JACK STUDS METAL FLASHING AT ALL EAVES, SIDEWALLS, WALL STUD FLOOR JOIST DEPTH USP NUMBER DESCRIPTION APPLICATION AND RAKES -- PROVIDE HEMMED EDGES SO RAFTERS AS TO FORM DRAINAGE CHANNELS AND INSTALL 4'0" O.C. PREVENT CAPILLARY ACTION 4" - 8" LSTA36 1-1/4"x36" 18go. STRAP AND JACK STUDS LOCATION USP NUMBER DESCRIPTION APPLICATION PRE-MANUFACTURED KEEP SHEATHING MIN. 1-1/2" ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH ON ALL OPENINGS RAFTER/PLATE RT15 TYDOWN ANCHOR CONNECT EACH RIDGE VENT FOLDS FROM PEAK TO ALLOW FREE THE PROPER STEEL CONNECTOR.INSTALL 4'0" O.C. RAFTER TO PLATE OVER RIDGE TO AIR PASSAGE IF ABLE, SET FIR JOISTS APROX. 1/2" HIGHER THAN LVL HEADERS 16" MSTA48 1-1/4"x48" 16 go. STRAP AND JACK STUDS CONFORM TO SLOPE TO ALLOW FOR SHRINKAGE. REDUCE BUMP OUTS 9 CONNECT OVER OF ROOF ON ALL OPENINGS PLATE/WALL SPTH4 STUD PLATE ANCHOR PLATES TO EACH STUD DBL. SILL PLATE TERMITE SHIELD SILL GASKET - _, �— SUBFLOOR m a WOOD JOISTS ' NEOPRENE CONC. SLAB GASKET 2x6 2x8 CONTINUOUS WOOD PLATE Dorn m o TYP. CONC. FOUNDATION ^ / 6 MIL. POLY DAMPPROOF EXTERIOR e � _ BOLTED TO STEEL BEAM WITH � r+ GRANULAR FILL 1/2 " DIA. BOLTS C� 48" o.c. STAG. o 6MIL POLY ON EXTERIOR �' ' ' 10 ' , ( p X ' V STEEL COLUMN a _ ' I cu 'a A i • d • d o, o < ROOF JACK �� ' o y 0 I~ o u CONC. SLAB ' '6 ��e ' ��� �.� STEEL BEAM Hd a • _ en 4" x 1/4" x 8" STEEL z COMPACT FILL . * ( TOP AND BOTTOM PLATE �n U �_ ROOFING LAPS m V ° C ° " FLASHING AT WITH 1/2" x 6" ANCHOR BOLT " KEYWAY FOOTING o A � a CONC. FTG. C SIDES AND TOP 1/2" GROUT o W e ,� I O ANCHOR BOLT CONNECTION USE WITH 3x3 SQUARE WASHERS �� cv v o , (USP LBPS58 OR BP583) REINFORCING BAR 1 1 3" STEEL COLUMN FOUNDATION 5/8" DIA. ANCHOR BOLT I DRAIN TILE > p + ANCHOR BOLT CONNECTION SUPPORTING MAXIMUM SPACING FLASHING LAPS ( 10 KIPS ) SILL PLATE TO FOUNDATION ROOFING AT BOTTOM CRAWL SPACE OR FOUNDATION) 1 STORY 72" OC SILL PLATE TO FOUNDATION TYPICAL BEAM DETAIL W TYPICAL CONC. FOUNDATION. APPLY PILASTERS MIN. 3" STEEL COLUMN ANCHORED TO 24%24%12" CONC. FTG. CRAWL SPACE OR FOUNDATION 2 STORIIES 36" OC STEEL / BOTTOM BEARING WHERE NEEDED FOR STRUCTURAL BRACING. WALL BOTTOM PLATE TO FOUNDATION 1-2 STORIES 57" OC (J SLAB-ON-GRADE ROOF JACKS & VENTS DETAIL I O SUBFLOOR CONC. SLAB I DOOR FRAME 6X6 10 10 WWM GE JOIST COMPACT FILL DOOR USE 2X8 STEEL BEAM -"•� FOR BLOCKOUT Q 4" SLAB \ W/ 6X6 WMM \ I SLOPE P.T. PLATE 4"DRIVEWAY -- NOTCH JOIST AND ADJUST HEIGHT 1/2" AIR PACE ��� e_ 1 0 < • ° 7, 1 �" (WITH A NAILING PLATE IF NEEDED) x AT END AND ES OF WOOD �,� ',� • • ° • '` •�'• ° TO BE APROX. 1/2" OR HIGHER THAN G ADE a .'-"'n-'-"-_u----'' * , e p BEAMS _ o •gyp o' ep •a • .• STEEL BEAM TO ALLOW FOR SHRINKAGE o .�•'a l!' Q Q a Tr_ I • ' d 0• ' • ' • I (PROVIDE STRAPPING TO KEEP JOISTS ALIGNED) �. 6X6 W.W.M. •�� - - - - -,yr r s —771 o o MIN. ° ,o�c o o c '� �'4 l!'a Q A.1, e o ®�.� NOTCH BEAM FOR MUDSIILL IF REQUIRED -- MAXIMUM n SUBFLOOR •� 4 r REINFORCING BAR NOTCH EQUALS 1/4 DEPITH OF BEAM i p o' • " oo ,• �II a O ,o•o � II—II GIST �1 L` REINFORCING BAR O • s o _ DRAIN TILE L—�rI o s s SHEET METAL 30 FELT UNDER BEAM AT POINT II • a L�'n Os 0• — ', A 12' / # QI STEEL BEAM 4• OF CONTACT WITH CONCRETE OR CONC. BLOCK ;. `.r,.`.`'"`'" a 3" PLATE (BOLTED TO BEAM , TYPICAL CONC. MONOLITHIC FOUNDATION. REINFORCE WITH (2) #4 REINFORCING BARS THICKEN SLABS BENEATH BEARING WALLS AND COLUMNS. •. • SHIMS TO LEVEL BEAM '=,{� .Y REINFORCE FOOTING WITH (2) #4 REINFORCING BARS. 3" MINIMUM BEARING SURFACE FOR WOOD BEAM GARAGE DOOR BLOCKOUT j,�'' � . •� '.^ f,.-•{ � DRAWN: MH/MS SCALE: 1/4"=1'-0" JOB BEAM POCKET „ N 'f.sF <.,.fr y,�' ;.�. #: s. r + ovember 16,2012 SHEET NUMBER: PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS A- 10 MANUFACTUREIR'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: VIND LOAD PATH CONNECTION AND CONSTRUCTION DETAIL DRAWINGS USE THE FOLLOWING OR APPROVED USP METAL CONNECTORS FOR PROPER WIND RESISTANT CONSTRUCTION. FOLLOW MANUFACTURE'S RECOMMENDED INSTALLATION INSTRUCTIONS TO ACHIEVE MAXIMUM UPLIFT LOAD CAPACITY. 4"MAX. KING STUDS T 4" DIA.MAXIMUM RAFTER CRIPPLE STUD CLIMATIC&GEOGRAPHIC DESIGN CRITERIA •. • GROUND WIND SEISMIC FROST WINTER ICESHIELD FLOOD LEDGER SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYIMENT HAZARDS RIDGE HEADER LOAD (MPH) CATEGORY DEPTH TEMP. REQUIRED ••.• 45 LBS. 120 B SEVERE 3 FT. MODERATE SLIGHT TO 114] 1 1 1 1 1 TO HEAVY MODERATE 11 NONE - _2 RAFTER JACK STUDS ZD M RAFTER-TO-LEDGER CONNECTION LEDGER TO BE CONNECTED TO BLDG. USING 1/2" DIA. BOLTS @16"OC WITH WASHERS HEADER-TO-POST/STUD CONNECTION DECK AND COVERED PORCH NOTES: RIDGE-TO-RAFTER CONNECTION RAFTER SIZE USP NUMBER DESCRIPTION APPLICATION LOCATION USPNUMBER1 DESCRIPTION APPLICATION 1). Unless otherwise noted, all framing material to be#1 ACQ pressure treated lumber. LOCATION USP NUMBER DESCRIPTION APPLICATION 2x6-2x8 LS26 18ga. SLOPE HANGER APPLY TO EACH RAFTER/LEDGER ALL OPENINGS LSTA12 1-1/4"x12"20ga.STRAP APPLY TO EACH JACK STUD All fasteners,hangers and anchors to be galvinized or stainless steel. STAIR RAILING ROOF LSTA24 1-1/4"x24"20ga.STRAP APPLY OVER RIDGE TO EACH RAFTER 2X10 LS210 18ga. SLOPE HANGER APPLY TO EACH RAFTER/LEDGER ALL OPENINGS RT3 OR RT7 TYDOWN ANCHOR APPLY TO EACH CRIPPLE STUD 2). Girders for deck joists to be bolted or anchored to each post or pier with washers and nuts. �" I Girders on concrete piers shall be anchored with proper steel connectors anchored 1-1/2"SPACE into concrete with a minimum 1/2"dia x 7"long anchor bolt with washers and nuts. rl� a MINIMUM 3). Posts supporting girders shall be anchored to a minimum 24"x24"x12"thick concrete footing. Use a minimum 1/2"dia x 7"long anchor bolt with washers and nuts. Footings Shall W W HANDRAILS RAFTER be 3 ft. below grade. Q 4). Deck joists to have blocking at 8'0 o.c.. Z RAFTER 5). Flashing shall be installed between the building and ledger. Lapping up the sheathing y U and over the ledger. Ledger to be fastened to building with 1/2"dia. bolts with washers • POST and nuts at 16"o.c. .• F' TOP PLATE 6).Concrete piers shall be a minimum 6"above grade. z • TOP PLATE O U BALUSTERS 7).All joists to be supported with hangers and anchors. Each Joist shall also be anchored RIM/DECK JOIST o to girders}. OPEN BALUSTER ATTACHED TO WALL WALL STUD WALL STUD C 8).Covered Roofs shall be assembled and anchored the same manner as a typical building. n 9). Use simpson hangers and anchors with Z-MAX tripple protective coating or equal F�-1 HANDRAIL C:ONNECTION RAFTER TO PLATE/STUD CONNECTION for any contact with ACQ. RAFTER TO PLATE/STUD CONNECTION ALL HANDRAILS SHALL E3E CONTINUOUS THE FULL LENGTH LOCATION USP NUMBER DESCRIPTION APPLICATRON 01:THE STAIRS. HANDGRIP PORTION OF ALL HANDRAILS LOCATION USP NUMBER DESCRIPTION APPLICATION CONNECT[-EACH RAFTER/PLATE RT15 TYDOWN ANCHOR NAILING SCHEDULE SHALL NOT BE LESS THAN 1-1/4"NOR MORE THAN 2"1N 4"-6"RAFTER RTIO 10-3/4"x 18ga.TYDOWN ANCHOR CONNECT TO RAFTER TO) PLATE POST-TO-DECK CONNECTION CROSS SECTIONAL DIMENSION,OR THE SHAPE SHALL EACH RAFTER CONNECII.OVER USE MIN. (2) 1/2" DIA.GALV. BOLTS WITH WASHERS AND NUTS PROVIDE AN EQUIVALENT GRIPPING SURFACE 8"-12"RAFTER RT20 21-1/8"x 20ga.TYDOWN ANCHOR CONNECT TO PLATE/WALL SPTH4 STUD PLATE ANCHOR PLATES TO EACH STUD ROOF SHEATHING, EACH RAFTER NAIL NAIL JOINT DESCRIPTION Qom, SPACING NOTES STRUCTURAL PANEL gd AS PER TABLE 3.8 WFCM-SBC 4"MAX. 4"DIA.MAX1MlllM GIRDER/HEADER ROOF FRAMING: O 0 GIRDER/HEADER ° JOINT DESCRIPTION NAIL NAIL NOTES U � ° ° QTY.JOIST POST/COLUMN o SPACING RAFTER TO 8 WALL: 3-8d COMMONEACH ►— �' zo D ° TOP PLATE 10'WALL:4-8d COMMO RAFTER TOE-NAIL p! m POST/COLUMN CEILING JOIST 8'WALL: 3-8d COMMON EACH TO TOP PLATE 10'WAIL:4-8d COMMO JOIN TOE-NAIL R1 � CEILING JOIST TO AS PER TABLE 3.7 EACH FACE M GIRDER/HEADER PARALLEL RAFTER WFCM-SBC LAP NAIL CEILING JOIST LAPS AS PER TABLE 3.7 EACH FACE POST-TO-GIRDER/HEADER CONNECTION OVER PARTITION WFCM-SBC LAP NAIL LOCATION USP NUMBER DESCRIPTION APPILICATION COLLAR TIE AS PER TABLE 3.4 EACH FACE TO RAFTER WFCM-SBC END NAIL SPLICED JOISTS OVER HEADER/GIRDER 4x4 SOLID COLUMN PBS44/PBSE44/KC44 POST CAP ANCHOR APPLY TO EACH COLUMN BLOCKING EACH TOE LOCATION USP NUMBER DESCRIPTION APPLICATION POST-TO-GIRDER/HEADER CONNECTION DECK/PORCH MAILING SPLICED SOLID COLUMN PBS66/PBSE66/KC66 POST CAP ANCHOR APPLY TO EACH COLUMN TO RAFTER 2 -8d COMMON END NAIL RIM ARD EACH JOIST TO GIRDER/HEADER I RT10 ITYDOWN ANCHOR CONNECT TO EACH JOIST HOLLOW COLUMN SIMPSON STRR1/2 H.C. ANCHOR APPLY TO EACH COLUMN USE MIN. (2) 1/2"DIA. GALV. BOLTS WITH WASHERS AND NUTS TOO BOFTER 2-16d COMMON END NAIL 0 rr) N � c7 C a\ h uO 0) D r',,, STU WALL FRAMING: m o BEARING PLATE r+ `�° o GIRDER JOINT DESCRIPTION NAIL NAIL NOTES Q • QTY. SPACING w CCU • TOP PLATE TO PER cn ° TOP PLATE 2 -16d COMMO FOOT FACE NAIL 0 TOP PLATES AT` JOINTS FACE WOOD JOIST G v • a' • 4 16d COMMO • " INTERSECTIONS EA. SIDE NAIL U cn x STUD TO 24" FACE U ^ °: LEDGER "• >� "' 2 -16d COMMON CONCRETE PIER "" STUD O.C. NAIL ;fl cn ° GIRDER/HEADER I I HEADER TO 16" O.C. FACE N c' HEADER 16d COMMON ALONG EDGES NAIL WOOD JOIST 16d JOIST " •'�"" , x W a• TOP OR BOTTOM 2-16d COMMO PER 2x4 STUD END ` PLATE TO STUD 3-16d COMMOIN PER 2x6 STUD NAIL DOUBLE 2x BOTTOM PLATE TO: PER FLUSH JOISTS WITH HEADER/GIRDER I (MINIMUM) FLOOR JOIST, BAND JOIST, 2-16d COMMOI, FOOT FACE NAIL CEILING JOIST TO BLD)G, CONNECTION ALL JOISTS CONNECTED TO A FLUSH HEADER TO BE SUPPORTED WITH END JOIST OR BLOCKING I I FO W FOR HEADER HEADER/GIRDER-TO-POST CONNECTION W LEDGER TO BE CONNECTED TO BLDG. IUSING 1/2"DIA. BOLTS @16"OC WITH WASHERS THE PROPER STEEL CONNECTOR. I I OR BEAM LOCATION USP NUMBER DESCRIPTION APPLICATION IF ABLE, SET FIR JOISTS APROX. 1/4"HIGHER THAN LVL HEADERS TO ALLOW FOR SHRINKAGE. REQU REED I 1 (2) BEAMS PAU44 OR WE44 POST/BEAM ANCHOR APPLY TO EACH PIEP U FOR STU (3) BEAMS PAU66 OR WE66 POST/BEAM ANCHOR APPLY TO EACH PIER O DECK FRAMING: FLASHING TUCKED UNDER I I JOINT DESCRIPTION NAIL NAIL NOTES TOP PIECE OF SIDING AND o� QTY. SPACING LAPPED OVER FIRST CONTIN. JOIST TO: PER TOE H PIECE OF SIDING BELOW THREADED ROCS SILL,TOP PLATE OR GIRDER 4-8d COMMON JOIST NAIL Q BRIDGING EACH TOE 1/2"DIA- LAG BOLTS W/WASHERS CNW COUPLER.NUT TO JOIST 2-8d COMMON END NAIL CONNECTED TO BLDG. @16"OC POST BLOCKING EACH TOE MIINIMUM TO JOIST 2-8d COMMON END NAIL (1 WOOD JOIST END DISTANCE BLOCKING BLOCKING TO: EACH TOE Q SILL OR TOP PLATE 3-16d COMMOIs I BLOCK NAIL � MINIM M LEDGER STRIP 3 16d COMMO EACH FACE FLOOR FRAMING ;� a o TO BEAM JOIST NAIL 2x JOISTS o+�o END ANICE " o " • • O 12 xl2 xl2 JOIST ON LEDGER PER TOE WOOD GIRDER '. '• CONCRETE FOOTING •• `" t".. TO BEAM 3 Sd COMMONJOIST NAIL BLOCKING FOR BAND JOIST PER END LAG BOLTS •p p 3 -16d COMMO JOIST HANGER > TO JOIST JOIST NAIL co• pl SILL OR TOP PLATE FOOT , 6•, ,` ��; HOLLOW COLUMN UPLIFT BAND JOIST TO: PER RIM JOIST/BD. 2 -16d CO TOE NAIL SIMPSON STRONG TIE MODEL STRRI/2 DECK POST FTG. CONNECTION ""� �t»: °K -A SPLICED JOISTS OVER HEADER/GIRDER INSTALL AS PER MANUFACTURE'S RECOMENDATIIONS ' '. PROVIDE BLOCKING BETWEEN JOISTS THAT ARE SPICED AND LOCATION USP NUMBER DESCRIPTION APPLICATION ` DRAWN: MH/MS USE WITH RTIO TYDOWN ANCHORS DECPORCH 4X4 POST PAU44 OR WE44 POST/BEAM ANCHOR APPLY TO EACH FOOTING ' ^-M1� ,Yr SCALE: 1/4"=1'-0" f rat `K/ LEDGER E CONNECTION JOB#: 6X6 POST PAU66 OR WE66 POST/BEAM ANCHOR APPLY TO EACH FOOTING " " November 16,2012 , . SHEET NUMBER: PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS MANUFACTURER'S WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SITE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR.TO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC,PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS. REVISIONS: GENLRAL *N- ` 0TES WiND FRAMING NOTES NAILING SCHEDULE NYS CODE: 2010 EDITION PLAN CONTENTS: ® 1). RIDGE-TO-RAFTER ASSEMBLY: ROOF FRAMING: OCCUPANCY CLASSIFICATION R3 RESIDENTIAL 1-1/4" x 20 gauge strap shall be attached to each pair of rafters in accordance to table 3.4. MAIL NAIL BUILDING USE RESIDENTIAL DWELLING When a collar tie is used in leu of a ridge strap, the number of 10d common nails required JOINT DESCRIPTION QTY SPACING NOTES CONSTRUCTION NOTES: in each end of the collar tie need not exceed the tabulated number of 8d nails in the strap. RAFTER TO 8'WALL: 3�-8d COMMON EACH BUILDING HEIGHT (SEE PLANS) TOP PLATE 10'WALL: 4-8d COMMON RAFTER TOE-NAIL 1). The information within this set of construction documents is related to basic design 2). RAFTER-TO-WALL ASSEMBLY: TOTAL SQ. FT. OF CONSTRUCTION (SEE PLANS) intent and framing details. They are intended as a construction aid , not a substitute Lateral framing and shear wall connections for rafter, ceiling or truss to top plate shall be in CEILING JOIST 8'WALL: 3-8d COMMON EACH TOE-NAIL for generally accepted good building practice and compliance with current New York accordance to table 3.3. When a rafter or truss do not fall in line with studs below, rafters TO TOP PLATE 10'WALL: 41-Bd COMMON JOIST State building codes. The General Contractor is responsible for providing standard or trusses shall be attached to the wall top plate and the wall top plate shall be attached to CEILING JOIST TO AS PER TABLE 3.7 EACH FACE DESIGN CRITERIA PRESCRIPTIVE AS PER N.Y.S. RESIDENTIAL CONSTRUCTION CODE AND construction details and procedurres to ensure a professionally finished, structurally the to the wall stud with uplift connections. Roofs overhanging the rake side of the building PARALLEL RAFTER WFC;M - SBC LAP NAIL CURRENT SBC HIGH WIND EDITION WOOD FRAME CONSTRUCTION MANUAL sound and a weatherproof complieted product. shall be connected with uplift connections in accordance with table 3.3c. CEILING JOIST LAPS AS PER TABLE 3.7 EACH FACE FRAMING ELEMENTS AS PER FLOOR PLANS CROSS SECTION AND GENERAL NOTES OVER PARTITION WFC',M - SBC LAP NAIL EXT. BALCONIES 60 2). The General Contractor is responsible for ensuring that all work and construction 3). WALL-TO-WALL ASSEMBLY: COLLAR TIE AS PER TABLE 3.4 EACH FACE DECKS 40 meets current federal, state, county and local codes, ordinances and regulations, etc. Wall studs above and studs below a floor level shall be attached with uplift connections in TO RAFTER WFC;M - SBC END NAIL These codes are to be considered as part of the specifications for this building and accordance with table 3.3b. When wail studs above do not fall in line with studs below, the ATTICS w/o STORAGE 10 should be adhered to even if in variance with the plan. studs shall be attached to a common member in the floor assembly with uplift connectors in BLOCKING 2 - 8d COMMON EACH TOE ATTICS w/ STORAGE 20 accordance with table 3.3. TO RAFTER END NAIL DESIGN LOAD CALCULATIONS ROOF (GROUND SNOW LOAD) 20 3). Dimensions shall take precedent over scaled drawings. RIM BOARD EACH END (LIVE LOADS PSF) (DO NOT SCALE DRAWINGS). 4). WALL ASSEMBLY TO FOUNDATION: TO RAFTER 2 - 16d COMMON END NAfL ROOMS (OTHER THAN SLEEPING) 40 First wall studs shall be connected to the foundation, sill plate, or bottom plate with uplift ROOMS (SLEEPING) 30 4). The designer has not been engaged for construction supervision and assumes no connectors. Steel straps shall have a minimum embedment of 7 inches in concrete WALL FRAMING: STAIRS 40 0 responsibility for construction coordinating with these plans, nor responsibility for foundation and slab-on-grade, 15 inches in masonry block foundations, or lapped under NAiL NAIL construction means, methods, techniques, sequences, or procedures, or for safety the plate and nailed in accordance with table 3.3b. When steel straps are lapped under the JOINT DESCRIPTION NOTES GAURDRAILS ANY DIRECTION 200 QTY. SPACING (DESIGNED FOR CAT.C) precautions and programs in connection with the work. There are no warranties for a bottom plate, 3 inch square washes shall be used with the anchor bolts. Anchor bolt EXPOSURE CATAGORY specific use expressed or implied in the use of these plans. spacing is to be spaced and sized in accordance to table 3.2a. In addition to spacing, TOP PLATE TO PER FACE NAIL W 2 - 116d COMMONLOAD PATH SEE CONSTRUCTION ANDWIND PATH CONNECTION anchor bolts are to be spaced between 6-12 inches from the end of a sill plate and all TOP PLATE FOOT SEE NOTE: 1 w Q 5). Refer to the Window and Door schedule for exterior openings. corners. TOP PLATES AT JOINTS FACE ROOF - FOUNDATION DETAIL PAGE & GENERAL NOTE PAGE Z 4 - 116d COMMON INTERSECTIONS EA. SIDE NAIL NAILING SCHEDULE SEE GENERAL NOTE PAGE p 6). The General Contractor is to ensure that masonry or prefabracted fireplaces meets 5). TYPE I EXTERIOR SHEARWALL CONNECTIONS: STUD TO 24" FACE EGRESS SEE FLOOR PLANS AND WINDOW SCHEDULE U or exceeds manufacture's specifications and applicable codes. Type I exterior shear walls with a minimum of 7/16 inch wood structural panel on the exterior 2 - 116d COMMON attached with 8d common nails at 6" o.c. at the panel edges and 12" o.c. in the field, and STUD O.C. NAIL FIRE PROTECTION Sym.: 7). The General Contractor is to consult with the owner for all built-in items 1/2 inch gypsum wallboard on the interior attached with 5d cooler nails at 7" o.c. at panel HEADER TO 16(d COMMON 16" O.C. FACE SMOKE &CO2 DETECTORS ® SEE FLOOR PLANS such as bookcases, shelving, pantry, closets, trims, etc. edges and 10" o.c. in the field shall be in accordance with the length requirements specified HEADER ALONG EDGES NAIL Cn in table 3.15a-b. TOP OR BOTTOM 2 - 116d COMMONPER 2x4 STUD END TRUSS DESIGN N/A - STANDARD STICK FRAME CONSTRUCTION O U 8). Wind load requirements shall be taken into account during construction. PLATE TO STUD 3 - 116d COMMON PER 2x6 STUD NAIL ENERGY CALCULATIONS RESCHECK 6). TYPE It EXTERIOR SHEARWALL CONNECTIONS: BOTTOM PLATE TO: FOUNDATION NOTES: Type 11 exterior shearwalfs shall meet the requirements of table 3.15a-b times the appropriate FLOOR JOIST, BAND JOIST, 2 - 116d COMMO FOOT SEE NOTE: 1,2 PER FACE NAIL CLIMATIC & GEOGRAPHIC DESIGN CRITERIA NIQ1). The General Contractor and �vlason to review plans, elevations, details and notes to length adjustment factors in table 3.16. END JOIST OR BLOCKING GROUND WIND SEISMIC FROST WINTER ICESHIELD FLOOD F--i determine intended heights of fimished floor(s) above typical grade. FRAMING:: SNOW SPEED DESIGN WEATHERING LINE TERMITE DECAY DESIGN UNDERLAYMENT 7). INTERIOR SHEARWALL CONNECTIONS: FLOOR HAZARDS �r Allowable sidewall lengths provided in table 3.14 shall be permitted to be increased when LOAD (MPH) CATEGORY DEPTH TEMP. REQUIRED 2). All footing!: to rest on undistulrbed (virgin) soil. NAIL NAIL interior shearwalls are used. Sheathing and connections shall be in accordance with JOINT DESCRIPTION NOTES 2.4.4.2 and 2.2.4 respectively. 4 - 8d COMMON QTY. SPACING 20 LBS. l20 B SEVERE 3 FT. MODERATE SLIGHT TO 11 NONE - 3). Provide 1/2" expansion joint material between concrete slabs and abutting JOIST TO: PER TOE TO HEAVY MODERATE concrete or masonry walls occuriing in exterior or unheated interior areas. 8). CONNECTIONS AROUND EXTERIOR WALL OPENINGS: SILL, TOP PLATE OR GIRDER JOIST NAIL ROOF SHEATHING REQUIREMENTS FOR WIND LOADS: Header and/or girder connections shall be attached with uplift connections in accordance BRIDGING EACH TOE 4). Any new concrete walls being attached to existing concrete epoxy for shallr installation. with table 3.5. Window sill plates shall be have steel connectors in accordance with table TO JOIST 2 - 8d COMMON END NAIL SHEATHING LOCATION NAIL SPACING NAIL SPACING AT INTERMEDIATE be installed with #5 re-bar, 18" long at 12" o.c.. Use approved epoxy fo NOTES 3 5 BLOCKING EACH TOE AT PANEL EDGES SUPPORTS IN THE PANEL FIELD 5). Unless otherwise noted, all slabs on grade to be 2500 s.i.. Concrete to be 2 - 8d COMMON 4' PERIMETER EDGE ZONE 8d COMMON 6" O.C. d COMMON 6" O.C. SEE NOTES: 1,3 g p• TO END NAIL @ @ poured on 4 inch thick sand or&ravel fill with 6x6 wire mesh reinforcing. Interior slabs 9)• CATHEDRAL CEILING ASSEMBLY: SEE NOTES: 1 BOTH FIELDS to be minimum 3-1/2 inch thick. ,All fill to be compacted to 95% relative density with Where a ridge is to be used as a structural beam, the rafters shall either be notched and BLOCKING TO: EACH TOE INTERIOR ZONE 8d COMMON 6" O.0 8d COMMON 12" O.C. ( ) 3 - 16d COMMON @ @ NOTE: 2 FOR PANEL FIELD (layers). anchored on top of the beam or slope connectors shall be attached to each rafter-to-ridge SILL OR TOP PLATE BLOCK NAIL �j 6 maximum lifts along the open ceiling part of the building. Connections to the ridge and wall shall be be LEDGER STRIP EACH FACE GABLE ENDWALL RAKE AND RAKE TRUSS 8d COMMON @ 4" O.0 8d COMMON @ 4" O.C. SEE NOTES: 1,3 Q O 6). Crawl spaces to be provided)with a minimum 18"x24" access opening. Install one attached with the above requirements. TO BEAM 3 - 16d COMMON JOIST NAIL 04 8x16 cast iron foundation vent for every 150 sq. ft. of area. DECK AND COVERED PORCH NOTES: JOIST ON LEDGER 3 - 8dCOMMON PER TOE NOTES r 7). Dampproof exterior of foundation with bituminous coating as required by current TO BEAM JOIST NAIL THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. Ct N.Y.S. Residential Construction Code. A 6-milpolyethylene film shall be applied over 1). Unless otherwise noted, all framing material to be #1 ACQ pressure treated lumber. H pp g BAND JOIST PER END the below grade portion of exteriior walls prior to backfillin . All fasteners, hangers and anchors to be galvinized or stainless steel. TO JOIST 3 - 16d COMMONJOIST NAIL g P P g 1). For roof sheathing within 4 feet of the perimeter edge of the roof, including 4 feet on each side of the roof peak, M 8). Drainage its required by current N.Y.S. Residential Construction Code. 2). Girders for deck joists to be bolted to each post with washers and nuts. BAND JOIST TO: 2 - l6d COMMON PER TOE NAIL the 4 foot perimeter edge zone attachments required shall be used. Girders on concrete piers shall be anchored with proper steel connectors anchored SILL OR TOP PLATE FOOT SEE NOTE: 1 FRAMING NOTES into concrete with a minimum 1/2" dia x 7" long anchor bolt with washers and nuts. R F ATH1N 2). Tabulated ]2 inch o.c. nail spacing assumes sheathing attached to rafter/truss framing members with G>0.49. For framing members with <0.42<G<0.49, the nail spacing shall be reduced to 6 inches o.c. 1). All framing;techniques and methods as prescriptive design of current SBC High Wind NAIL NAIL 3). Posts supporting girders shall be anchored to a 12 x12 x12 thick concrete footing. JOINT DESCRIPTION QTY SPACING Edition Wood Framing Construction Manual. Use a minimum 1/2" dia x 8" long anchor bolt with washers and nuts. Footings Shall be 3 ft. 3). Tabulated 4 inch o.c. nail spacing assumes sheathing to rafter/truss framing members with G>0.49. For below grade. Porches with covered roofs shall have 12" dia. concrete piers for the girders. STRUCTURAL PANEL 8d AS PER TABLE 3.8 framing members with 0.42<G<0.49, the nail spacing shall be reduced to 3 inches o.c. 2). Unless otherwise noted, all framing and structural wood material to be #2 + BTR. I WFCM - SBC WALL SHEATHING REQUIREMENTS FOR WIND LOADS: Douglas Fir. 4). Deck joists to have blocking at 8'0 o.c.. CEILING SHEATHING: SHEATHING LOCATION NAIL SPACING NAIL SPACING AT INTERMEDIATE NOTES 3). Floors, walls, ceilings and rafters to be spaced at 16 inches o.c. unless noted AT PANEL EDGES SUPPORTS IN THE PANEL FIELD g P 5 . A minimum of 10 inch flashin shall be installed between the buildin and led ledger. NAiL NAIL g g g JOINT DESCRIPTION N cu E otherwise. Ledger to be fastened to building with 1/2" dia. bolts with washers and nuts QTY. SPACING SEE NOTES: 1, 3 ( BOTH FIELDS) v g 4' EDGE ZONE 8d COMMON @ 6" O.C. 8d COMMON @ 12" O.C. c. where needed. GYPSUM 7" O.C. EDGE NOTE: 2 FOR PANEL FIELD X v 4). Unless otherwise noted , all bearing wall headers to be (2) 2x10 #2 + BTR. Doug. Fir. 5d COOLERtS o r� WALLBOARD 10 O.0 . FIELD INTERIOR ZONE 8d COMMON @ 6 O.0 8d COMMON @ 12 O.C. SEE NOTE: 3 Bearing wall headers to have (2) jack studs and (2) full length studs on each side of all 6). Concrete piers shall be a minimum 6" above grade. openings. LVL headers to have ('3) jack studs and (2) full length studs on each side of WALL SHEATHING: Or w openings. Beaming wall window gills shall also have (2) window sill plates for 2x4 wall 7). All joists to be supported with hangers and anchors. Each Joist shall also be anchored NOTES z M E NAIL NAIL o v ao * openings between 4'1 and 6'0 and 2x6 wall openings between 5'll and 8'9. Provide fire to girder(s). JOINT DESCRIPTION THESE NOTES ARE ONLY TO BE REFERRED TO IF MENTIONED IN SCHEDULE NOTES ONLY. 6n 4 and blocking where applicable. QTY. SPACING o 4 8). Covered Roofs shall be assembled and anchored the same manner as a typical building. STRUCTURAL AS PER TABLE 3.9 " " w Yp g 8d COMMO 1). For wall sheathing within 4 feet of the corners, the 4 foot edge zone attachment requirements shall :�. ' 2 5). All flush beams/headers to be installed with heavy duty galvinized hangers and PANELS WFCM - SBC anchors where applicable to all connecting joists. PLUMB iNG NOTES be used. U m -, ' ON 7/16" OSB 3"O.C. EDGE N v E 6d COMMON 6). Double up floor joists under'walls that run parallel to the floor joist and under bathtub . 1). All water supply, drainage and venting to be installed as per N.Y.S. Residential PLYWOOD 6" O.C. FIELD 2). Tabulated 12 inch o.c. nail spacing assumes sheathing attached to stud framing members with o w X. Floors to have ceramic the installled shall be verified for proper load capacity unless noted Construction Code. GYPSUM 7" O.C. EDGE G>0.49. For framing members with 0.42<G<, the nail spacings shall be reduced to 6 inches o.c. WALLBOARD Sd COOLERtS 10" O.0 . FIELD on plans. 3). For exterior panel siding, alvinized box nails shall be permitted to be substituted for common nails. 7). Provide 2 - 1-3/4" thick microlams ( height to match floor joists) around stairwell and/o 2). Verify septic system with the Engineer for Suffolk County Health Department approval. FLOOR SHEATHING: ) p g' g other access openings unless otheerwise noted (typical). NOTE: un 3). If wall studs, plates or joists are cut out during installation for any plumbing related work, NAIL NAIL W provide adequate bracing and plates to protect and secure the structure. Verify with the JOINT DESCRIPTION CONTRACTOR TO PROVIDE SOIL TEST TO VERIFY H 8). Dormers running up roof raftters are to be supported by double rafters on either side P q g P p Y QTY. SPACING state code and manufacture's recommendation for maximum hole size and spacing permitted. where applicable unless otherwisse noted. STRUCTURAL PANELS 6" O.C. EDGE EXISTING CONDITIONS. MINIMUM 3000# CAPACITY. u HVAC SYSTEM NOTES V OR LESS sd coMl\vlo 12" O.C. FIELD 0 9). Provide blocking/bridging ink floor joists at 8'0 o.c.. Use solid blocking in floor joists 1).PROVIDE 5/8"TYPE-X SHEETROCK FIRE STOPPING AT 10'0 MAXIMUM DISTANCES FOR NON ACCESSIBLE AREAS. Ln under all bearing walls. 1). Mechanical subcontractor is responsible for adhearin to all applicable codes and safety NOTES 2).USE SIMPSON HANGERS AND ANCHORS WITH Z-MAX TRIPPLE PROTECTIVE COATING FOR CONTACT WITH ACQ. Q' P g pP y •' 3).INSTALL 1-Cot DETECTOR IN ADDITION TO SMOKE ALARMS PER FLOOR. �► 10). Provide insulation baffles ate eave vents between rafters. install draft blocking as requirements. THESE NOTES ARE ONLY TO BE REEFERRED TO IF N needed. 2). HVAC subcontractor is to fully coordinate all system data and requirements with the MENTIONED iN SCHEDULE NOTES ONLY, d 11). Unless otherwise noted, all roofs and walls to have a minimum 1/2" thick, 4-ply Fir equipment supplier. 1). Nailing requirements are based on wall sheathing „ as required by current NYS Residential Code-FIREBLOCKiNG REQUIRED CDX exterior sheathing grade pf,,ywood. Plywood to cover over plates and headers. 3). HVAC subcontractor to provide final system layout drawing and submit it to the General nailed 6 on-center at the panel edge. If wall sheathing Fireblocking shall be provided to cut off all concealed draft openings(both vertical and horizontal) Contractor and owner for final review and approval. is nailed 3" on-center at the panel midge to obtain higher and to form an effective fire barrier between stories,and between a top story and the roof space. 12). Unless otherwise noted use :3/4" thick T&G PTS Fir or Advantech plywood subfloor shear capacities, nailing requiremernts for structural ELECTRICAL NOTES: Fireblocking shall be provided in wood-frame construction in the following locations. adhered with PL400 adhesive amd screwed to floor joists. Finished floor to be installed members shall be doubled, or alternate connectors, 1).In concealed spaces of stud walls and partitions,including furred spaces,at the ceiling and floor over subfloor as per manufacture"s instructions. such as shear plates, shall be used to) maintain load path. levels.Concealed horizontal furred spaces shall also be fireblocked at intervals not exceeding 10 1). All electrical to be installed as per N.Y.S. Residential Construction Code. feet.Batts or blankets of mineral or glass fiber shall be allowed as fireblocking in walls constructed 13). All bathroom walls to have 11/2" thick moisture-resistant sheetrock. Garage walls and using parallel rows of studs or staggered studs. ceilings and over furnace to have 5/8" thick type-x sheetrock. All other parts of building 2). All electrical work shall be approved by a qualified Underwriter. 2).When wall sheathing is continuous over connected members,the tabulated number of mails shall be permitted 2).At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, to have regular 1/2" sheetrock. Atli walls to be taped and finished. drop ceilings and cove Ceilings. �; 3). Install Smoke detectors and Carbon Monoxide detectors throughout q hout as required by current to be reduced tog - 116d nail per foot. fr,, „k 14). All roof with a pitch less thain 4:12 shall be installed with an Ice &Water barrier or N.Y.S. Residential Construction Code. 3).In concealed spaces between stair stringers at the top and bottom of the run.Enclosed spaces under stairs shall comply with current N.Y.S.Residential Code. i approved equal. Flat roofs shall be applied with a Fiberglas base sheet with an EPDM 4).At openings around vents,pipes and ducts at ceiling and floor level,to resist the free passage of r,,,,:.„r: _, ;.1 torch down type material over. DRAWN: MH MS flame and products of combustion. / SCALE: 1/4"=V-0" 16). All sill plates and wood in contact with concrete to be pressure treated. Sill plates to 5).For the fireblocking of chimneys and fireplaces,as required by current N.Y.S.Residential Code. .� o�`A_. _ JOB#: be installed with a foam sill gaskcet and cop-r-tex termite shield or approved equal. rti. `'�' �x t�f November 16,2012 SHEET NUMBER: PAINTER TO PRIME AND PAINT ALL DOOR EDGES TO MAINTAIN CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES BETWEEN THE DRAWINGS,THE SPECIFICATIONS,AND THE FIELD CONDITIONS,AND SHALL REQUEST CLARIFICATION BEFORE COMMENCING WORK. CONTRACTOR SHALL VERIFY ALL GENERAL CONTRACTOR TO COORDINATE MEETING WITH OWNERS FOR APPROVAL OF ALL GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL BUILDING DEPARTMENT INSPECTIONS 12-w MANUFACTURER'S\WARRANTY AND SHALL BE INSPECTED TO VERIFY ALL WORK. DIMENSIONS AND CONDITIONS AT JOB SITE,INCLUDING BUILDING AND SiTE CLEARANCES FOR DELIVERY OF EQUIPMENT AND MATERIALS,AND REMEDY ALL DISCREPANCIES WITH ARCHITECT PRIOR ITO THE COMMENCEMENT OR CONTINUATION OF WORK. ROUGH ELECTRIC.PLUMBING,AND HVAC PRIOR TO INSULATING AND SHEETROCKING AND SHALL SECURE THE C of 0 PRIOR TO RECEIVING FINAL PAYMENT FROM OWNERS.